<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2194</title>
    <subtitle>Add Specimen and Container Type to Preparation Template</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>June 2022 Voting Packet</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2022/04/03</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie <link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>IDC</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2021/11/20</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2194</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Specimen and Container Type to Preparation Template</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16, PS3.17</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The Specimen Preparation template does not specify either the Container Type or the Specimen Type of the sample, though the included Specimen Sampling template does specify the Parent Specimen Type.</para>
                    <para>This information is useful to understand the scope of the Specimen Identifier.</para>
                    <para>Add Container Type and Specimen Type as optional, specify the appropriate Context Groups for values, and update the example to include the new concepts.</para>
                    <para><emphasis role="italic">[Ed.Note: Incorporates changes from CP 2143 Correct code for microscope slide (final text incoprorated in 2022a).]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: The example uses the part/block/slide 1 specimen per container model but there is no SNOMED CT code for "Block", so (430861001, SCT, "Gross specimen") is used instead, which has the FSN "Macroscopic tissue specimen (specimen)" with a synonym of "Gross tissue specimen". This may not be a good choice, and SNOMED CT contains many procedure concepts that use "Block" in their name, e.g. 434288009 | Procedure on tissue block (procedure) and its many children, but these are not formally modeled. See SNOMED CSR# 764962 to add Tissue block (specimen) as new concept.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Ideally the example would be illustrated with a figure. The obvious choice would be PS3.17 Figure NN.4-1. But though it is widely reproduced and referenced and used in the HL7 Specimen DAM
                        (<link xl:href="http://www.hl7.org/implement/standards/product_brief.cfm?product_id=499"/>)
                        and in Christel Daniel's canonical paper
                        (<link xl:href="http://doi.org/10.5858/133.11.1841"/>),
                        it is not ideal because it uses words like "dice" rather than "block" and fails to clearly distinguish containers (e.g., cassettes) from specimens (e.g., blocks, not quite the same as dice, per Christel Daniel's paper).
                        Should we take this opportunity to revise the figure and make it match the example exactly?]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.16 as follows, according to this pattern:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="TID 8001" status="3" xml:id="sect_TID_8001">
            <title>Specimen Preparation</title>
            <para xml:id="para_c4365a93-570f-4d99-8525-25b31068c5fe">This Template describes a single specimen preparation step.</para>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_64f3ad96-5514-49f4-b944-7253995c5ced">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_1ac7c20d-78f9-4990-b187-6015f0dbd6c6">
                        <emphasis role="bold">Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_75ab5e52-b409-4a32-bf70-bfe321d48310">
                        <emphasis role="bold">No</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 8001" rules="all" xml:id="table_TID_8001">
               <caption>Specimen Preparation</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_35bea843-6064-4665-a18b-33324d700a20"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_20a81a6e-5ec1-4ab7-8781-3c6801a35b91">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_80c76678-4936-4e9c-bc5d-dd6408b081ec">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_02e3f65f-9283-452f-87b2-d20ce2412b4b">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_de3be3dd-e988-42d8-9a2d-afc8e01e5a21">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_faf72b56-4f3c-489b-bfc5-e34fbeb31fcf">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_13818311-b83c-4d85-a001-5fd9b818cb6f">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c4ad2d80-ef61-43ae-9ded-072282b70450">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_27fae3f8-ce30-42c8-801c-4fde4092f35e">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_911bdcd9-68c8-4d70-b7cb-988a6583e6ee">EV <link linkend="DCM_121041" xrefstyle="select: nopage">(121041, DCM, "Specimen Identifier")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_69ea33d3-cd87-4a5a-ade5-bb0e61a32a09">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1aa2b4dc-7494-406e-bbb0-e4a67a6a7d4f">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cd9d5877-accf-4959-87fb-6692fb0ecb40"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_32f9864c-f812-4b45-a82a-011f10e9c747"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7793136e-9d58-44ef-a030-8e964ad521a3">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dd603f2e-9d1a-4b76-9c51-eafccc7684a9">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_605a2f2e-806f-4300-a237-108ffa75cada">EV <link linkend="DCM_111724" xrefstyle="select: nopage">(111724, DCM, "Issuer of Specimen Identifier")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_758b4786-6bcf-4669-8ba9-da424da53652">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a8bcb41f-e828-485a-966f-68a302156e9d">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e6f0e9fd-3d5f-4ba2-b0c3-1d0b6cb46510"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a41c02f8-d35c-4e79-a3b4-81e129a3d20b"/>
                     </td>
                  </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">2a</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">DT </emphasis></emphasis><link xl:href="http://snomed.info/id/434711009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434711009, SCT, "Specimen container")</emphasis></emphasis></link>
                            </para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para/>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">B<xref linkend="sect_CID_8101" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                            </para>
                       </td>
                   </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">2b</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">DT </emphasis></emphasis><link xl:href="http://snomed.info/id/371439000" xl:show="new"><emphasis role="bold"><emphasis role="underline">(371439000, SCT, "Specimen type")</emphasis></emphasis></link>
                           </para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para/>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">B<xref linkend="sect_CID_8103" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                           </para>
                       </td>
                   </tr>
                   <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d9b18251-7e2e-4030-826d-67379c7d36a8">3</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6354e858-27a5-4f98-b7ed-e34d806d6811">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3887bee0-9e13-4e4c-a03d-dd6529e28e6b">EV <link linkend="DCM_111701" xrefstyle="select: nopage">(111701, DCM, "Processing type")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_aa1e3dee-bda9-45e4-a41b-6920b79bc4c2">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7c407a99-b190-4300-8ac1-5f0e2eed9fe2">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5cd5631c-27dd-4761-8809-5a591e88d54a"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_74c2a23e-5ad9-41e9-b486-d603e4c0711d">D<xref linkend="sect_CID_8111" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fa268db5-ed45-41cd-8969-058f33a31d0c">4</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cfe8b5d3-5edb-435e-85f3-6738d3af470c">DATETIME</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_132f72d0-c3cf-4ab0-a1c3-b7b8d511384c">DT <link linkend="DCM_111702" xrefstyle="select: nopage">(111702, DCM, "DateTime of processing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d1f9b76d-b936-49d9-bbec-0e02a23fabae">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5c072485-57a8-479f-8cdb-342cc59a646a">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_44768508-eec3-4241-974f-a751bd5c7b85"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d86bdf4-5e6a-42b0-b71a-6ccc97627f96"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1a27ea6b-d162-4ac6-973f-f95d44707e64">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9efe9d99-3f4d-4ebc-841d-96169137932f">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c6676d2d-d32c-4c8d-b19f-05717363019d">DT <link linkend="DCM_111703" xrefstyle="select: nopage">(111703, DCM, "Processing step description")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_47bc4688-81b9-4cd1-a4f6-6637e7d38eca">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c42a30f0-e8fc-4aa6-9e21-7e462f3bebdc">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_76f733c2-48e5-428e-88d4-7b032d76c212"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c1b28735-2ed1-469f-a19c-e9216ba957ce"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_49e1eb7f-c49a-472a-a88b-f67c837dcfa8">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_98e4f078-1759-4640-beb8-ea7dce68f138">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bcc5ee6b-462f-41d2-b89f-a026d85cf740">DT <link linkend="DCM_111703" xrefstyle="select: nopage">(111703, DCM, "Processing step description")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3b9989b7-db50-4218-862e-74944b8636e0">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_03fa29a8-605b-4f9b-9704-da2b47027440">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dcda806e-2dcb-4394-9713-3ece924de82c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9e15ca07-e978-40ff-864c-6ed9a81146d6">D<xref linkend="sect_CID_8113" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_163c7c16-cf63-4adc-9b7c-06fe32f9b2af">7</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a05aa89d-48b9-4041-a5fc-87b21887ff69">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_45dc3020-5e39-4207-a9b9-e1104a292173">DT <link xl:href="http://snomed.info/id/17636008" xl:show="new">(17636008, SCT, "Specimen Collection")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d4b2e1f5-c72d-42d7-b71c-1a5bc7778866">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_16f4083c-a581-4e96-a1f8-c9d399f334fa">MC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_24afbed2-f8df-475e-9906-dbd6d49d24ca">IFF Row 3 Processing Type value is <link xl:href="http://snomed.info/id/17636008" xl:show="new">(17636008, SCT, "Specimen Collection")</link>
                        </para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ee3c2913-daaf-4a7e-bfb7-0642dce797e5">B<xref linkend="sect_CID_8109" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bd95a952-2c8e-48fb-9ae4-e31b34b28641">8</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_482eebdc-f748-46a7-8756-4c932819c713">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_06f60bdb-0bf1-4283-925e-f0f58456a0c6">D<xref linkend="sect_TID_8002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_84a3c007-26a1-4236-8866-3cd7b8c0f4a1">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d7c8f515-e48f-4df2-b87b-cf027b4018f7">MC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9c40317b-a310-4473-840d-7519c6297909">IFF Row 3 Processing Type value is <link xl:href="http://snomed.info/id/433465004" xl:show="new">(433465004, SCT, "Specimen Sampling")</link>
                        </para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5ce4ef5b-d7c1-4a19-a074-a09e3b8809ae"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1c12a9f1-d3bf-416f-b3eb-343382727f4f">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4ce11d43-0295-41e6-8f36-ad963c7d6cd5">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_664fe5e2-d53a-4613-925f-dc68988c60f5">D<xref linkend="sect_TID_8003" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4d3691c1-3a01-40cb-a63b-b7b73fcfcc34">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ffbd6a68-0ef1-419c-a7b0-c61a369899fd">MC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_59ecbc2e-dda8-4cf5-a75e-8b18142a6442">IFF Row 3 Processing type value is <link xl:href="http://snomed.info/id/127790008" xl:show="new">(127790008, SCT, "Staining")</link>
                        </para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a98a12e3-f196-4aca-96d3-b630508cd773"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f4568fb0-d31b-4ec7-93aa-f4102134ecb7">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1c97945e-804c-4d7f-89f6-3203b3b4f621">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_72d323dc-91ac-42a1-bd01-a2127872839b">DT <link xl:href="http://snomed.info/id/430864009" xl:show="new">(430864009, SCT, "Tissue Fixative")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c888c9b4-b94f-4905-9d38-2284cb8acff5">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a65a74da-f5d9-43ec-b8e2-24c3af6d598a">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_32a37086-0546-466c-b7ae-272c3908a33f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bc0e6a77-f188-4cac-a6fa-57bef4be498e">B<xref linkend="sect_CID_8114" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5238eddb-4ef4-4cf2-90a1-c248ad796f8b">11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_757f276d-421e-40ef-9df1-8e1ffb09c2ec">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_003c24b8-cb28-41cc-bf98-91c8e986cab4">DT <link xl:href="http://snomed.info/id/430863003" xl:show="new">(430863003, SCT, "Embedding medium")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6b2780f3-d221-437d-b683-9514c7c08fb4">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_821a8c00-ddeb-424d-a6ce-60e76c48e687">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f4a2041a-5f1e-47c6-bad8-3ede6d9c4ca1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e6e89ad9-8a54-4c0a-b7a6-69e110a69d48">B<xref linkend="sect_CID_8115" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_79e1b4b9-1f83-4e38-b96c-329d4c046a7b">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_befc4d5b-8a12-479a-ac1b-e11bf2674e3b">Row 1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0162fbb1-184a-46ea-b844-f998c5343649">For sampling steps (which create a child specimen from a parent), the ID is that of the child specimen. For other preparation steps, the ID of a specimen does not change during the processing.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aa164932-bed9-4f12-b0e9-d5e828fdd600">Row 2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f1c65c6c-beb8-4db3-9a37-8d0e41269b5d">The issuer shall be formatted in accordance with the HL7v2 Hierarchic Designator Data Type. That format is [ 
                <emphasis role="italic">Namespace ID</emphasis>]^[ 
                <emphasis role="italic">Universal ID</emphasis>^ 
                <emphasis role="italic">Universal ID Type</emphasis>], where 
                <emphasis role="italic">Namespace ID</emphasis>identifies an entity within the local namespace or domain, 
                <emphasis role="italic">Universal ID</emphasis>is a universal or unique identifier for an entity, and 
                <emphasis role="italic">Universal ID Type</emphasis>specifies the standard format of the Universal ID (see HL7 v2 Section 2.A.33).</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>
        
        <section label="TID 8002" status="3" xml:id="sect_TID_8002">
            <title>Specimen Sampling</title>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_19f92109-b9ea-4a10-ab97-94a725729351">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_a79bd364-d1c2-49a2-9552-a645efdf6703">
                        <emphasis role="bold">Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_329efbca-46f7-462a-8403-e9edad84c5fb">
                        <emphasis role="bold">No</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 8002" rules="all" xml:id="table_TID_8002">
               <caption>Specimen Sampling</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_549bb678-9dac-4423-a14e-c7fd3ceb744b"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_60f29a99-ab8e-4abe-ac4c-91511f54130c">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_98565fce-8a7f-431d-9e33-3e340d77f1b8">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_17a167df-9a9d-4291-8c20-d53cf2aef0db">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f5be70a1-258e-4ef0-aa24-7b229f0723a3">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4538d3dc-1b24-49b7-b426-8cc953cb1e05">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0f110527-bbb8-4188-8533-9ec22a8c0132">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6a970ff2-c0ae-4a7d-8bed-ef5276ecc027">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5c1b3c99-92e0-40ef-a1ae-fccfed31b03c">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6fafd691-f245-496b-b593-bc0c1409e120">DT <link linkend="DCM_111704" xrefstyle="select: nopage">(111704, DCM, "Sampling Method")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_468064f9-ef5a-45a8-99ea-ca57d0205400">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3dda7631-4d8e-42ba-9211-158437298bac">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cd99240e-5a67-4b42-b9e7-4b530ecf12f4"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b6d57135-8167-4358-9866-d9d7814a8e77">B<xref linkend="sect_CID_8110" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c6211e10-c948-4d02-ad9c-b7ea2abfd350">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d0654e29-bc56-4bf1-8759-b464ae72bc8e">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6be3c863-4342-43d7-b626-dda00ca7c668">DT <link linkend="DCM_111705" xrefstyle="select: nopage">(111705, DCM, "Parent Specimen Identifier")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_dde3d699-231f-4c7d-9d8e-630b3537af87">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5c9434d8-0dfa-4ee7-be7a-7ce8e09b30ff">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3da32369-e53a-4baa-9078-6402d21080bc"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b47194a7-432d-490f-a62f-062b49d8997e"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_087aaf77-9729-4e51-8f6a-1840cb12fa5d">3</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ec649157-d317-43ce-85a3-6164314ea57d">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52852a4c-9e8c-41f4-8025-5702f6f5dd93">DT <link linkend="DCM_111706" xrefstyle="select: nopage">(111706, DCM, "Issuer of Parent Specimen Identifier")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_461bfc19-7af4-4491-bd65-a4a5e9d5b78f">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3484ab4e-6022-4dc7-9d13-6bef5702be1c">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_73239b3e-4244-4321-a0b5-8b56a1ef8f48"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_09d9e126-86ab-42d9-8fbd-870f9bcd94d7"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e52421d1-deb8-477d-9cbc-1ece20da1138">4</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e8051d33-496a-46df-b41f-618580eb252e">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_63f54331-41b4-4b59-a016-69da0738c0e4">DT <link linkend="DCM_111707" xrefstyle="select: nopage">(111707, DCM, "Parent specimen type")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_33a741f2-26a2-46e6-8ccd-3b89295c2837">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d58ef027-c197-4045-935c-5d30c784dd98">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5eb42d37-4da6-4629-8d36-306385abc563"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2e37040c-ae38-4153-8352-d7f7d316c319">B<xref linkend="sect_CID_8103" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a6c9fd83-2c1d-45a3-946a-b4a25743ed8c">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6ce65144-c8ff-4938-8623-0a02a231a9d8">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9954afa3-a561-4454-9ef8-4f9a1c808e95">DT <link linkend="DCM_111708" xrefstyle="select: nopage">(111708, DCM, "Position Frame of Reference")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b8538998-5e57-4c49-9d39-588aebf7c730">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d522d338-1837-42b6-ba93-35022c88c299">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fd746af7-cfd4-4fa9-83e2-1d303838c6be"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c43f7a78-9da7-40d7-a5ea-5f38d95ff87d"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cb855572-6388-4ffe-b99f-e992e93219ff">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_61a4fdb2-a6d0-4ae5-bd23-3971dcf26724">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ca38ab4c-e888-4385-b785-49e0ce6de7a0">DT <link linkend="DCM_111709" xrefstyle="select: nopage">(111709, DCM, "Location of sampling site")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0d17b9cc-ca5e-4d8c-832a-203318b60893">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_af02fc43-94d2-49b1-9a5e-12fc8764a3e2">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_90f4d53b-a5c9-4620-bfbe-ea4918a0d796"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_45152d47-f2ed-4cff-884c-be794873ab13"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_00c42838-0f43-412e-b33d-6315ef70ff0b">7</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5e94e124-4708-4278-aeae-e1b2a472ff9d">NUMERIC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_83700bc3-e5ff-4779-88b0-8d9572dae07e">DT <link linkend="DCM_111710" xrefstyle="select: nopage">(111710, DCM, "Location of sampling site X offset")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cea81a32-5b8f-4e1b-9e15-0735023152b1">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fd06e38b-cba0-4bb3-b6d3-9b3cc31bee49">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_03d7d4bb-e2d0-4485-baaa-30ef7aec0955"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aa580bde-7767-4e83-ad11-c1d3de06baf5"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0dc137ab-8f51-49fc-b631-2b9129361955">8</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_31f9ae33-e841-4890-a1cd-905efb7d57b5">NUMERIC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f1d82f75-9c37-4a32-b447-72b2314503ab">DT <link linkend="DCM_111711" xrefstyle="select: nopage">(111711, DCM, "Location of sampling site Y offset")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4738ac30-cf30-4d41-8153-b0119a8cb481">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8455a04f-f863-450a-a8e7-c4b0012da8a6">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_de0524ae-bf54-4cd2-8ba2-f85a21b9e4db"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dc978d74-de1c-49e7-9d7b-9b73e4767546"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9c9105bc-7142-4cea-b247-c2ba2bcfa8b3">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_764b6108-3d07-4d34-8df1-f211f61df87a">NUMERIC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9fdb89ff-c3b8-41d8-a255-2fd9e29706f9">DT <link linkend="DCM_111712" xrefstyle="select: nopage">(111712, DCM, "Location of sampling site Z offset")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ff4659e1-d50b-4e2c-9004-860be28a4af8">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_53073e77-4fdf-48b0-946e-6c050b6068c3">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_31420b25-b3dc-4c28-8dd8-f49d1f7a4124"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_33c217a8-3a10-447b-905e-7e30b4f2b833"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5f084496-4a64-4eac-b6e8-5b970f2569c0">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e8c42e8-a1e6-4331-914b-e0861cf3ea53">IMAGE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bb11ab86-1c70-437e-a8dd-137930f051e7">DT <link linkend="DCM_111709" xrefstyle="select: nopage">(111709, DCM, "Location of sampling site")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c71024d3-dbdd-4726-9600-6b4ae669ac77">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_125c8614-be82-4323-8d38-802876c9a453">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3645c45c-d9cb-469f-8064-86a282e67d88"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_15c0811d-b194-40d9-90a3-a4f968ff2a98"/>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_cf92eb81-3bca-437e-bf7b-15689814aaa5">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c03268c1-0d8c-4163-890a-aa7256c80024">Row 3</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52867bd1-47b0-4ff4-b040-b00d6d8f7351">The Issuer of Specimen Identifier shall be formatted in accordance with the
                  HL7 v2 Hierarchic Designator data type (see HL7 v2.6 Section 2.A.33), i.e., [
                    <emphasis role="italic">Namespace ID</emphasis>]^[ <emphasis role="italic">Universal ID^Universal ID Type</emphasis>]</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e81e539c-1eba-4e82-88f8-b1e386fde6fa">Row 5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_37807fd0-69a2-4e53-93df-cd5122a69254">Description of coordinate system and origin reference point on parent specimen or parent specimen container used for localizing the sampling site</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_96911528-abbd-4965-885e-80e40660f3a0">Rows 7-9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_008b74b4-29f8-409a-9e38-84bb09ff70bd">The X, Y and Z locations are used as needed to describe the sampling site; not all may be needed. E.g., resection from 10 cm along the colon may be described as only a Y dimension location.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6ac19276-a86f-48d8-8829-f124a54e9935">Row 10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fe0446c9-4118-4fe9-996e-99065bb3f253">Reference to image of parent specimen localizing the sampling site; may include referenced Presentation State object</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>
        
        <section label="CID 8101" status="3" xml:id="sect_CID_8101">
            <title>Container Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_01b8e2b0-dcf3-4788-a55d-06d14ef3b714">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8101.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-8101-ContainerTypes.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-8101-ContainerTypes.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1043.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f8217bcc-7c46-41b0-aa7b-bdb6fafb9586">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f9bdfda5-b5d5-43dc-9186-b743f04ffc6e">
                            <emphasis role="bold">20080626</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_8d4d2f5f-5d72-4ccf-97be-88570c5790b7">
                            <emphasis role="bold">1.2.840.10008.6.1.1043</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8101" rules="all" xml:id="table_CID_8101">
                <caption>Container Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8bad6506-cd9c-4c83-8530-0d9a26fc057a">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5c7c1e45-cbea-4027-a4f3-2b2aa4d6b568">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_349c7f27-f896-40e9-af3f-629d17cc062b">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_336ebc1f-5195-4c0d-ae59-5defa87d7855">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e09dd8b-a9b6-43a3-92d1-b91660a43c18">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dcfcf7ef-4edb-4c19-ad8f-0b01716d65cd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e145bed-0a9f-4041-a5ca-0bd18af82e03">
                                <link xl:href="http://snomed.info/id/434464009" xl:show="new">434464009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_32b10e49-9a7e-4b83-925d-055f3798f711">Tissue cassette</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_827eb104-ff19-44e0-bdaa-1145750e3873">
                                <link xl:href="http://snomed.info/id/434464009" xl:show="new">A-0101E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cc9eb79-9146-4d54-966a-61413a6b3e45">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0183953" xl:show="new">C0183953</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09775f22-368e-4e1c-96bc-be5ca6bdf37d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba30bb70-ea7a-4eea-84ee-a7854d86394b">
                                <link xl:href="http://snomed.info/id/434708008" xl:show="new">434708008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9d87ff34-ee3c-4cf9-97cc-767ef94a86a5">Tissue microarray cassette</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c50931d8-b014-4ecd-bc72-8ed3968eefec">
                                <link xl:href="http://snomed.info/id/434708008" xl:show="new">A-01022</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06807332-7a22-47ac-bb29-436fbe70ef21">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2315967" xl:show="new">C2315967</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6afe7716-c282-4b92-9a7d-ad5e09840cf0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c65c965-874e-4ffc-b992-2213d40a440d">
                                <link xl:href="http://snomed.info/id/434746001" xl:show="new">434746001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e987774d-5fb7-4c75-8613-35fdd7b6a7c6">Specimen vial</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ed8b091-b325-449d-9408-86a823349a46">
                                <link xl:href="http://snomed.info/id/434746001" xl:show="new">A-01024</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd530aae-d8ef-432d-8dfb-85f5cdb427ea">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2316421" xl:show="new">C2316421</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b3947d5-6f0f-410c-9821-2949d389ccda">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e1532d1a-db31-49d8-a42e-f1db85eaf682">
                                <link xl:href="http://snomed.info/id/433466003" xl:show="new">433466003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ea309ef1-0de8-4c35-9e9c-04ab80006ed2">Microscope slide</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df0d6638-5166-4e62-86bc-4607ec2ea4aa">
                                <link xl:href="http://snomed.info/id/433466003" xl:show="new">A-0101B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8f1733e3-9a8d-4c63-9b5c-4a0b3525cef3">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0026017" xl:show="new">C0026017</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3496464-d866-4933-8097-3cd7055fe9f0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b71f7e43-c574-4946-b756-5db3d283f8d8">
                                <link xl:href="http://snomed.info/id/434711009" xl:show="new">434711009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ab71977e-2709-4701-9fa7-d95a20972ab7">Specimen container</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3ae0684e-d517-4c30-83d5-cd568943238e">
                                <link xl:href="http://snomed.info/id/434711009" xl:show="new">A-01023</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91800039-17fe-468a-b40b-419feafaf4f1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0183391" xl:show="new">C0183391</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c32cfe46-2fc1-41d7-b1cf-9366e777e035">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e776b92-51d5-45a4-9e22-23edb754945e">
                                <link xl:href="http://snomed.info/id/434533009" xl:show="new">434533009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d4e175ef-f009-4103-9c4e-924289e16cab">Electron microscopy grid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e69bce37-3723-4de5-9970-4a7618c67f23">
                                <link xl:href="http://snomed.info/id/434533009" xl:show="new">A-01021</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8b1c52d-b32f-4617-b7bb-ca6fec3aa7f5">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2316945" xl:show="new">C2316945</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9da50bff-6274-4833-8bf9-b777396e9e79">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8d3bacf-15de-4055-8f75-850e280a2a3d">
                                <link xl:href="http://snomed.info/id/434822004" xl:show="new">434822004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1891fb71-daf7-4967-8c10-46a4deb32065">Specimen well</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8f967b15-1547-459e-a6df-feeca36bd144">
                                <link xl:href="http://snomed.info/id/434822004" xl:show="new">A-01025</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54cabfe6-1fbc-4752-90f6-2c5643b893c1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2316030" xl:show="new">C2316030</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 8103" status="3" xml:id="sect_CID_8103">
            <title>Anatomic Pathology Specimen Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f2ecc9e3-2028-4e2f-90ca-09f8dc8111f3">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8103.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-8103-AnatomicPathologySpecimenTypes.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-8103-AnatomicPathologySpecimenTypes.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1045.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_675c0809-3785-469b-afa2-b9be58b464ff">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_b0b3bd64-871a-4a70-bbfb-8fe212b58b4b">
                            <emphasis role="bold">20220115</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_4f78b32e-dd9a-463d-843e-1345f6b877a0">
                            <emphasis role="bold">1.2.840.10008.6.1.1045</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8103" rules="all" xml:id="table_CID_8103">
                <caption>Anatomic Pathology Specimen Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b9911023-cb0e-4044-83a4-c64090e7a3ea">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9904f845-0020-4850-9457-b93191f85ddc">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a19335b-b391-4729-9340-6c2108799431">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7423458b-fd72-4135-8ee9-136f5932067d">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7291500b-6e66-40a6-9ccf-7792b02eae34">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2fb4a0ae-e008-4dcc-bf58-9fc28d6db488">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de7f44c7-689d-4441-bbff-424a5347aa25">
                                <link xl:href="http://snomed.info/id/38266002" xl:show="new">38266002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_89540ccb-2103-43e4-bd9b-c9268eaa89de">Entire body</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64fb8325-fec1-4d7a-b88a-552ea0dec437">
                                <link xl:href="http://snomed.info/id/38266002" xl:show="new">T-D0010</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0cc9134b-9f36-407b-a1f7-3303aa71b392">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0229960" xl:show="new">C0229960</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df0a8b8c-6c50-4bf4-ae88-7090fdd9a2d9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_45c9ea01-93d5-4a74-b6a9-290dccc080c7">
                                <link xl:href="http://snomed.info/id/309050000" xl:show="new">309050000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5ae0f8a9-8471-4047-b337-bcee845eef8c">Body substance sample</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d5020ad2-4367-410c-83b7-24a650354792">
                                <link xl:href="http://snomed.info/id/309050000" xl:show="new">G-80A5</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9692103-3ad4-47b8-a4d0-960cf4511518">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0586522" xl:show="new">C0586522</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f19842ed-bdfc-4e22-9efa-5284c8c1d77d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_018fe094-f177-4984-8a30-d821ecb84785">
                                <link xl:href="http://snomed.info/id/309051001" xl:show="new">309051001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ebf561a0-4bc0-4cfe-b4d3-6471f2214a03">Body fluid sample</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b851821d-e39d-49d2-aa07-d781b14f5af6">
                                <link xl:href="http://snomed.info/id/309051001" xl:show="new">G-80A6</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83b1e7e7-a6bd-4e71-9aab-cd7716f34353">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1292527" xl:show="new">C1292527</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_237e6dff-27d9-4390-9cf6-361870a462e7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de6157db-5380-4923-8594-8ba507cbca44">
                                <link xl:href="http://snomed.info/id/119376003" xl:show="new">119376003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cab67e80-69d3-4487-9b71-390fdd77aece">Tissue specimen</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e4e95aa-0540-4f1b-a52e-51f2588db990">
                                <link xl:href="http://snomed.info/id/119376003" xl:show="new">G-8300</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d53a21ae-b92d-42ea-a9bf-b239fa6e9bf2">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1292533" xl:show="new">C1292533</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e41222f7-dd90-409a-8396-6be7e2a7489e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aefc1693-2bf6-4356-8375-544027383138">
                                <link xl:href="http://snomed.info/id/430861001" xl:show="new">430861001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1c163c99-b9e5-49de-b74e-f704745304aa">Gross specimen</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ce04c81a-fab7-4ac2-8677-c40f0e884825">
                                <link xl:href="http://snomed.info/id/430861001" xl:show="new">G-843A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c837bbfa-46d0-44fb-a4cf-67e68feda249">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2316367" xl:show="new">C2316367</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ddd6e8e0-9d81-4cb3-980b-6dec4901f4b5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b1e39079-0606-403e-bb62-4796396d865e">
                                <link xl:href="http://snomed.info/id/430856003" xl:show="new">430856003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d26d3abd-1e6b-4520-a899-db4b23b56a05">Tissue section</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_940b8f1b-9184-49b3-a833-a3b3de427ef4">
                                <link xl:href="http://snomed.info/id/430856003" xl:show="new">G-8439</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1fe0185c-35d6-4b45-8cfe-4f88d9caaf63">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2316368" xl:show="new">C2316368</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53b9a14c-4761-41c4-98b5-dcd2277de519">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eaaae75d-6ff7-4f65-8bb1-3c38ef6be75c">
                                <link xl:href="http://snomed.info/id/430970004" xl:show="new">430970004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5dcb837c-68d9-4aac-a284-ba6af7149985">Core sample of tissue block</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5431bc7e-f696-4699-9113-836fb97518c7">
                                <link xl:href="http://snomed.info/id/430970004" xl:show="new">G-843B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5046a607-8e52-4a0c-919d-19ca6c0faf01">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2316369" xl:show="new">C2316369</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e003a06a-fce9-4b42-8425-df9a3c16d8a0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5937dbc8-0fed-4114-b67c-1c2a579b09e9">
                                <link xl:href="http://snomed.info/id/431196006" xl:show="new">431196006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_de39b8f4-b68c-4c79-8b9a-ae51b07cb8c2">Tissue spot</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2a49b78-623e-41ab-a05b-1a8dea6b2794">
                                <link xl:href="http://snomed.info/id/431196006" xl:show="new">G-843C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ab35234-c140-45bd-b814-6561142e4ae2">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2316370" xl:show="new">C2316370</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c773d33b-599a-4120-8b01-dc46cbdc3868">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4eb6c022-c715-434d-963c-d774ad0deffd">
                                <link xl:href="http://snomed.info/id/1179252003" xl:show="new">1179252003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a264f206-6428-4ec5-8226-e96a2f717284">Slide</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b659019e-c967-4afa-a8b8-2f72633bf10a"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a8f942f-df81-4871-8ab5-97586cc4e796"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64c44970-30f0-45ea-9e49-23ee8f532bc3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3483b661-61cb-4021-8e3d-754cdc1402e8">
                                <link xl:href="http://snomed.info/id/258433009" xl:show="new">258433009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_64809cc8-7b8c-4b0b-9133-9cf56bc90c20">Smear sample</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_126e46b2-7f83-4e07-96ce-bda07e3cb57d">
                                <link xl:href="http://snomed.info/id/258433009" xl:show="new">G-803C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_15b94264-8860-44e5-b53d-5ad68e38cb93">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0444086" xl:show="new">C0444086</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_951be588-3af5-4991-a693-8973c539a618">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6ba0852-2021-462f-8d9c-25bfb4a79ab4">
                                <link xl:href="http://snomed.info/id/430855004" xl:show="new">430855004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_02a4add5-8ebb-4c2a-a21c-95eb17e81c2b">Touch preparation cytologic material</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eab64bd7-25a2-4ef5-b4c0-831b8af63ff4">
                                <link xl:href="http://snomed.info/id/430855004" xl:show="new">T-1A404</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87b5af8b-ee80-470e-9cc8-96b19682ba62">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2316942" xl:show="new">C2316942</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1624f05-c2c0-4e5a-8518-1a9447e83e4b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ddc1f260-ce09-4c15-a25f-f81a39a92b9c">
                                <link xl:href="http://snomed.info/id/430346005" xl:show="new">430346005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4b5a5d31-13dc-45cc-8202-a4eac1071e8b">Liquid based cytologic material</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80bc9788-d00f-481b-a655-db1e2e39561c">
                                <link xl:href="http://snomed.info/id/430346005" xl:show="new">T-1A403</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_00788ec7-14c0-4c93-8152-a7be8e703732">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2315942" xl:show="new">C2315942</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec34a41c-4ae0-4c73-a7e2-c53352dcadde">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_841b42ee-ff4b-4b7e-802b-a0c2ef2a0724">
                                <link xl:href="http://snomed.info/id/119295008" xl:show="new">119295008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c7a10ff9-1548-415c-875b-23b2856d5bfb">Aspirate</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df35a4df-3ad3-42d1-ab64-1460de298ede">
                                <link xl:href="http://snomed.info/id/119295008" xl:show="new">G-8003</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bdf81880-a90b-4295-b24d-3308a727879a">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0370199" xl:show="new">C0370199</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2711f5c7-e3cd-4c2b-ac81-832ea1e703e4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d5d183fb-97e3-44e2-ada1-48b11e1bbe88">
                                <link xl:href="http://snomed.info/id/258562007" xl:show="new">258562007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c91dba4d-9ae3-4376-ad33-89da529698fa">Genetic sample</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ecf62b70-eb43-47ce-8dfd-65c54123b99c">
                                <link xl:href="http://snomed.info/id/258562007" xl:show="new">G-81A0</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_29d856b9-feba-4d63-a0c2-ab9174ab13cf">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0444241" xl:show="new">C0444241</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_8646bfa5-d363-47be-a0c5-4984130d5d83">
                                <emphasis role="italic">Include <xref linkend="sect_CID_8104" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3a15a5d-9aec-4bd6-9619-e69e400e7735"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_72b0fecc-9d3f-4689-87bc-8d671a89bec8"/>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <para xml:id="para_c0473299-0681-49ef-b9b0-4a0158f5e677">The SNOMED CT concepts for specimens rather than corresponding concepts for physical objects are used in this Context Group.
                    <link xl:href="http://snomed.info/id/258661006" xl:show="new">(258661006, SCT, "Slide (specimen)")</link>
                    has been inactivated by SNOMED and replaced with
                    <link xl:href="http://snomed.info/id/1179252003" xl:show="new">(1179252003, SCT, "Slide submitted as specimen (specimen)"</link>.</para>
            </note>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr><td><para><emphasis role="italic">Amend DICOM PS3.17 as follows:</emphasis></para></td></tr>
        </informaltable>
        
        <section label="NN.4.1" status="3" xml:id="sect_NN.4.1">
            <title>One Specimen Per Container</title>
            <para xml:id="para_f62fb58a-176f-4b19-b253-6de3d00e29f5">In normal clinical practice, when there is one specimen per container, the value of the specimen identifier and the value of the container identifier will be the same. In <xref linkend="figure_NN.4-1" xrefstyle="select: label"/>, each slide is prepared from a single tissue sample from a single block (cassette).</para>
            <para xml:id="para_69ff5cc7-1b94-49ed-93ae-b102c291b388">
                <figure label="NN.4-1" pgwide="1" xml:id="figure_NN.4-1">
                    <title>Sampling for one specimen per container</title>
                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="cp2194/PS3.17_NN.4-1.svg"/>
                            <!--<imagedata fileref="figures/PS3.17_NN.4-1.svg"/>-->
                            <!--<imagedata fileref="part17_fromword_files/image343.png"/>-->
                        </imageobject>
                    </mediaobject>
                </figure>
            </para>
        </section>
        
                        <para xml:id="para_bdde4f8f-e68a-49ce-9ede-f242c42c5b0e">The example Specimen Preparation Sequence first describes the most recent processing of the slide (staining), then goes back to show its provenance. Notice that there is no sampling process for the slide described here; the LIS did not record the step of slicing of blocks into slides.</para>
                <table frame="box" label="NN.6-4" rules="all" xml:id="table_NN.6-4">
                    <caption>Specimen Preparation Sequence for Slide</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_864bb96e-f60a-4860-9f9c-ef29ad63dd23">
                                    <emphasis role="bold">Specimen Preparation Sequence - Item #</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52419eb6-3ee5-46f2-bcc8-2afea7293c23">
                                    <emphasis role="bold">Specimen Prep. Step Content Item Sequence - Item #</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_468abab7-5489-4387-8638-f902d7d35472">
                                    <emphasis role="bold">Template / Row</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7cba060a-3dd2-4f17-9a6f-dec2ca944475">
                                    <emphasis role="bold">Value Type (0040,A040)</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93e87f41-830c-441f-b242-c2281238ee6a">
                                    <emphasis role="bold">Concept Name Code Sequence (0040,A043)</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca0727bb-1edd-4634-9073-96571fd6925f">
                                    <emphasis role="bold">Example Value</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cac5974-cbb5-41a2-a8b2-5ddd3b7d96a5">
                                    <emphasis role="bold">Comments</emphasis>
                                </para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="8">
                                <para xml:id="para_3711c0fc-7ce1-4337-8ba1-1d0cd99be43f">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f56e214-629b-4d50-83be-b761efb28bb5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9a37953-13af-4c86-a507-e592ab775f06">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55129dc9-d80a-4362-bff8-b4dd18e3e02e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b876f67a-b8ad-4749-a99d-0337d95d163a">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c540d8d-f57f-4a3e-a886-500476717982">S07-100 A</para>
                            </td>
                            <td align="left" colspan="1" rowspan="8">
                                <para xml:id="para_8e6e61fd-b905-49fd-bfc6-d1e62df17811">Part Collection in OR.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20aa8564-919a-4ecc-91a0-869fa9d3395e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_957cbdc0-2703-4ba9-a929-584552a98360">8001 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5b4d10a-549d-428e-bfc4-8d7872bdb69f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84b619d1-de3e-44fd-ac25-d1beb3ebc05c">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111724">(111724, DCM, "Issuer of Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dba6e2d-c635-4af1-af4e-0500d07846a1">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                            <link xl:href="http://snomed.info/id/434711009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434711009, SCT, "Specimen container")</emphasis></emphasis></link>
                        </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                            <link xl:href="http://snomed.info/id/434711009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434711009, SCT, "Specimen container")</emphasis></emphasis></link>
                        </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                            <link xl:href="http://snomed.info/id/371439000" xl:show="new"><emphasis role="bold"><emphasis role="underline">(371439000, SCT, "Specimen type")</emphasis></emphasis></link>
                        </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/38866009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(38866009, SCT, "Anatomic part")</emphasis></emphasis></link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_812ca00a-a93b-4025-8532-6c15f66baa52">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16a84c9e-2b1e-439f-b325-7c1c85cca365">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29b33f75-60be-4f10-90a2-709fc0935ff9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f8efa24-fb03-4098-bcae-0574d6dacbb5">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59fb12ee-f30b-4929-910a-4239d46de219">
                                    <link xl:href="http://snomed.info/id/17636008" xl:show="new">(17636008, SCT, "Specimen collection")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb72b63b-9ccd-40f7-b7c5-dba7de79296a">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b410485e-56d4-47f1-9e5a-84f10d08be35">8001 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a270f57-b011-4f2b-a72d-ee43e9f8c135">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cb1d7cb-0991-4638-b0a9-dd948cd75b4d">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111702">(111702, DCM, "DateTime of processing")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e9ea21e-2cf4-492e-a755-1cae267f5085">200703230827</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72312b55-bfea-4974-99af-967f449434d1">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d294adf2-150e-4469-925a-30524cb40881">8001 / 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2ac2984-6c31-4a32-8b01-c4026399de26">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f80694ac-b6f9-43c8-8b3d-7e807ea18d59">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111703">(111703, DCM, "Processing step description")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc529ba4-c295-4e71-a8cc-9554ed826d52">Taken</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0088a772-2f60-44e6-b64b-09dd6f7b5287">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_caac58cc-b7c1-47ae-a388-81f9f5507bf6">8001 / 8</para>
                                <para xml:id="para_3265e4fb-d072-493b-b133-fba87d8a2490">8002 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5938e79-0440-469d-9a36-ce1a6efd4091">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5970ab00-f116-4daf-8c91-8ecb53e3fff6">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111704">(111704, DCM, "Sampling Method")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9b5288f-4df1-40c9-bbee-3235eb29ec8b">
                                    <link xl:href="http://snomed.info/id/65801008" xl:show="new">(65801008, SCT, "Excision")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="6">
                                <para xml:id="para_03fa8b59-99d5-4ca8-83f5-63166bd5eea2">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a24d43b0-a606-4a26-acf9-92a1910185c8">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f821c8e-f236-46b8-9aff-3770ac7b99ae">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77e149dd-6205-4144-a1c4-1c49bff00508">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f732c04b-444e-4c34-bd7c-de85767cbd86">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1fd1b25-fd14-47ee-a4d3-336914d8db20">S07-100 A</para>
                            </td>
                            <td align="left" colspan="1" rowspan="6">
                                <para xml:id="para_29cb7d10-c06c-492f-a5df-ea0611bc05a8">Specimen received in Pathology department</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e65db98-366b-45cb-a512-675708c2771b">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ccf6650-3e63-4823-8b76-a5e7b261d8d9">8001 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f31ec3b5-243e-4eb7-a7b0-070ba4d7de5e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b849ff9b-3824-4eb4-82cf-cc81862c8502">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111724">(111724, DCM, "Issuer of Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45b25cca-4b4e-4ed1-8f77-9075289b5908">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/434711009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434711009, SCT, "Specimen container")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/434711009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434711009, SCT, "Specimen container")</emphasis></emphasis></link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/371439000" xl:show="new"><emphasis role="bold"><emphasis role="underline">(371439000, SCT, "Specimen type")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/38866009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(38866009, SCT, "Anatomic part")</emphasis></emphasis></link>
                        </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df3fdce7-fe8b-4751-8a77-b9891a5100af">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63863117-8d7e-47de-8135-c7bc53f3652a">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21ac811b-04d9-4990-ba6a-f13f17e1119c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_930f6f40-d0ae-4419-a058-614cebe06f6e">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eecca750-0086-4b86-a76b-9d5df8a7f9d2">
                                    <link xl:href="http://snomed.info/id/428995007" xl:show="new">(428995007, SCT, "Specimen Receiving")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4218d740-c9dc-4ffd-9fa1-a5a3d3985514">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7d4e2b2-f094-428b-93f5-cefb156b36fb">8001 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37c9ba3e-5abe-4ddc-af27-d9a26b4aa1d5">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be903ba6-fc43-4385-a50e-4c38ba8ec040">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111702">(111702, DCM, "DateTime of processing")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5762b46-664e-4670-b13b-c105d31a4477">200703230943</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="11">
                                <para xml:id="para_fdc7d8b2-24e3-4c3d-925e-f1630b622d72">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27fedfe5-bedb-48bb-9db1-045bb8808a97">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9f85827-b53d-4489-a8b1-2bd2fdc880bf">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ab05fe9-4230-4285-a9b1-f552f647de5f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aecd330a-f89f-4d27-adc1-f298ca6ffe79">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c15057e-7c57-40da-9c35-02c74d330012">S07-100 A 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="10">
                                <para xml:id="para_9cae2e80-ec3f-4181-893b-09172cfdee5e">Sampling to block</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed0fb0c2-2ac9-499a-af34-74c8d6665b19">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8a29396-5635-4055-bc2a-cf4e5ccdba22">8001 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7999c6f-cee3-4c72-8efe-a695949beb78">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ba24d48-8e7c-44e1-8edd-ab2db979c630">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111724">(111724, DCM, "Issuer of Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fee35fcd-262f-4e10-befe-ac8c6d790635">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/434711009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434711009, SCT, "Specimen container")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/434464009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434464009, SCT, "Tissue cassette")</emphasis></emphasis></link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/371439000" xl:show="new"><emphasis role="bold"><emphasis role="underline">(371439000, SCT, "Specimen type")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/430861001" xl:show="new"><emphasis role="bold"><emphasis role="underline">(430861001, SCT, "Gross specimen")</emphasis></emphasis></link>
                        </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d01f3d1-d90c-48a9-9fc4-e30d7ed3a087">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c7495a0-b075-46d8-8506-f391b1599958">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f55249d1-482b-4b5c-95f1-58fe6990d6c5">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ee5bb84-45b9-449f-8c83-5cadc06f171f">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab3329d4-e0d0-4cfc-ba01-c6e49e4dfae9">
                                    <link xl:href="http://snomed.info/id/433465004" xl:show="new">(433465004, SCT, "Sampling of tissue specimen")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fec21f80-5ce3-497c-aa87-d4420446e726">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f53590a-297f-490c-a499-4740f99e5a25">8001 / 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffa9d535-6e8a-4584-b369-431674709b2b">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c027442-130e-4fab-820e-115c092d4a84">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111703">(111703, DCM, "Processing step description")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6d26d03-d700-4a23-a91b-3d6ca2a972ed">Block Creation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b0a4a5b-e4aa-4a3b-b3d8-d3ed91cb444b">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e79117f1-6cb4-4490-8ce1-70b1d903fa8c">8001 / 8</para>
                                <para xml:id="para_e9be9b2d-e3ae-4c8d-aeb9-7cbf6e9c0d34">8002 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b4cdf9e-5b0e-4849-80b7-44fa3511cf72">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b09805d6-3822-478d-a976-f50e64562bab">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111704">(111704, DCM, "Sampling Method")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c13ee2e5-a302-40c7-84d4-c950b2219b12">
                                    <link xl:href="http://snomed.info/id/122459003" xl:show="new">(122459003, SCT, "Dissection")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db293887-cc36-4144-952d-7a9441f5d444">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f67f97d9-0c1e-4c16-941b-0a7107705084">8001 / 8</para>
                                <para xml:id="para_ac16ba92-71c1-4759-a66f-4dfbb5fbbcbd">8002 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f0d14bc-6ab5-47a2-a31c-28d652498fa8">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d38112ff-4eb0-4902-9d12-7e23a257676a">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111705">(111705, DCM, "Parent Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f9bf3e4-b102-4bc0-9a90-344a90ec1377">S07-100 A</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86370f3e-0bdd-455a-8640-ba89fe4d8e23">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be15c27c-98c7-4262-b5b8-55537694095b">8001 / 8</para>
                                <para xml:id="para_b3aab40e-225d-4c13-aaba-16dfbcede1ab">8002 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1bc3ad8-5653-4aee-bb4a-506e692863b8">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02a10084-ef4f-458a-9e9b-7f17681e2df6">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111706">(111706, DCM, "Issuer of Parent Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24e0387b-c9b9-4fb9-bc83-883ae35afcca">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89bf16d7-b19d-4c31-a70a-4a3391caf771">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b3c5f4d-43fe-4ffd-9c23-72cbe883bd33">8001 / 8</para>
                                <para xml:id="para_3de8f881-4088-454f-b9ac-74e7ace016ad">8002 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa0c28de-f1e9-4e13-85d7-29a55806b4ba">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ccd5804-8370-4354-906f-d5148b149ba4">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111707">(111707, DCM, "Parent specimen type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0748b818-4683-431b-8e57-e9e7c110caf3">
                                    <link xl:href="http://snomed.info/id/38866009" xl:show="new">(38866009, SCT, "Anatomic part")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93280c1c-b670-4b07-8a73-59db13e29941">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c92d583-725b-4f83-9ae3-852b4a941210">8001 / 8</para>
                                <para xml:id="para_2ce44d58-3b97-4e34-9fa7-49091853f071">8002 / 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01e4eabb-8b44-41c7-89eb-a7eaed1059ca">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1acc765-cbae-4fbd-a868-c0f2864bf2bf">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111709">(111709, DCM, "Location of sampling site")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eea458e7-81db-4911-9ea2-bef2b1e55e3d">Mass</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d5cd052-89a9-408e-b3cb-bae57a51804b">This is coming from the summary of blocks field in the LIS</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="8">
                                <para xml:id="para_01a54c1e-10b1-4d09-9059-fbe828629733">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08621d0c-fe41-4d20-a15b-afa414f82c25">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0aab35d2-6395-4600-b360-5e597484094a">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa4efdcf-0801-4c0c-a0ee-53f9372ec7bc">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1eb114b-e994-4ed1-9d6c-b4a40eaef4c7">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44091566-929e-4dc0-b9ff-cd2f84a4704e">S07-100 A 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="8">
                                <para xml:id="para_9ae50e74-384e-428b-ab3f-78c27ab47bb2">Block Processing</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_995a7600-22c6-45c8-9bf7-e4e9c774696e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0d3c8f6-3410-43ef-b2b7-58dd7f0210cc">8001 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9534b618-0c71-4410-a216-4c4ac2924e2e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1b7743c-e653-4cb9-b2bf-e2db17cc9357">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111724">(111724, DCM, "Issuer of Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21820955-5eab-4ffc-abd1-1e54dad81436">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/434711009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434711009, SCT, "Specimen container")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/434464009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434464009, SCT, "Tissue cassette")</emphasis></emphasis></link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/371439000" xl:show="new"><emphasis role="bold"><emphasis role="underline">(371439000, SCT, "Specimen type")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/430861001" xl:show="new"><emphasis role="bold"><emphasis role="underline">(430861001, SCT, "Gross specimen")</emphasis></emphasis></link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4682f82-a11b-438d-b4f2-6229ce3ca563">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8621f43-fbe6-4747-a3f1-e8fd9ed050f8">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae3bbd9d-473a-48bc-bbc5-96ba80f8bab3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bd7e4c1-6e0a-4162-bb1a-d3832ff9e960">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55cb36e2-7db2-4f08-ab80-9e5df0be0943">
                                    <link xl:href="http://snomed.info/id/9265001" xl:show="new">(9265001, SCT, "Specimen Processing")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62e27498-2949-4597-89fc-61fbfa3e5420">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4f95146-6c0e-41da-a93e-cf3ef45aa5f4">8001 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71bd4e7e-0966-4877-be48-3d489ce68bf8">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f269496a-dc54-46cb-a321-70665bdaff46">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111702">(111702, DCM, "DateTime of processing")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c574592-6c62-4b1e-852d-1f18db25a11e">200703231900</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_528ded3f-ef3a-417e-923a-2c5dabbbca34">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5053bfae-66a6-4617-a3e8-3cec256bfa00">8001 / 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc1505cf-9195-405f-9491-2c2aeacd421d">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4021cc8-c472-4d44-aaf3-f367a7a7fd0c">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111703">(111703, DCM, "Processing step description")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e6a8bfc-69dd-49ab-933e-e07ca51b28a7">Standard Block Processing (Formalin)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_757aa67c-d253-434e-99de-67e5043c97b6">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23d12185-61ae-470b-90ab-aadbc05c9c24">8001 / 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8aa97d06-a890-4203-b0e5-3fceb1bc336e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a7011b8-ccdd-4abf-90ff-88d04150b553">
                                    <link xl:href="http://snomed.info/id/430864009" xl:show="new">(430864009, SCT, "Tissue Fixative")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_186011cd-4ce2-444d-bc9e-ff6d7147b051">
                                    <link xl:href="http://snomed.info/id/111095003" xl:show="new">(111095003, SCT, "Formalin")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="8">
                                <para xml:id="para_d080b277-668f-42f4-b9c5-91dc5a8902f4">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38ad8281-c88d-4704-b449-374ad630c780">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_447c93ec-fbce-4885-b499-f82eaf620ff0">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_245164f9-a350-41e6-b437-954734dcefbf">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b873be77-e4ef-4063-8527-fe86fef56680">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee94285e-3c23-42f4-922a-6bcf9aff35bd">S07-100 A 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="8">
                                <para xml:id="para_72f96072-3e98-4a64-99aa-e60d0fdbc497">Block embedding</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf4e6dd2-aef0-410e-b3e4-024ae5902e9d">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17fe59cc-5142-4a04-9b3b-8932b90e4d98">8001 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe27eef1-1f4d-4b24-9620-4846169807b1">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fed23a55-2c90-4fb8-81e1-f8ba8aa51b0e">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111724">(111724, DCM, "Issuer of Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eca40f52-eb21-441a-afa6-6754aa8ba7a8">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/434711009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434711009, SCT, "Specimen container")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/434464009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434464009, SCT, "Tissue cassette")</emphasis></emphasis></link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/371439000" xl:show="new"><emphasis role="bold"><emphasis role="underline">(371439000, SCT, "Specimen type")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/430861001" xl:show="new"><emphasis role="bold"><emphasis role="underline">(430861001, SCT, "Gross specimen")</emphasis></emphasis></link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6e3faa5-d6be-4d65-804d-890f3d5c8753">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d133423-d0b5-4fb3-8689-aeea40c5c4b2">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae453e40-1c76-4f73-9f7c-76a72be960b6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_929d97fd-a4cb-4613-8ad5-c62007cc07c5">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbb1a881-2963-43b9-b92e-b4a74c661ae5">
                                    <link xl:href="http://snomed.info/id/9265001" xl:show="new">(9265001, SCT, "Specimen Processing")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b6bd0dd-5f14-4545-bbf4-d2b7b61cf4de">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_884efc24-585b-4c9b-bcea-5fbff0f8a7e9">8001 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89071637-762f-4242-935d-6f18d97d55f7">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29cbd656-5402-4a98-89fd-6d3bec2cd42a">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111702">(111702, DCM, "DateTime of processing")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a28afc23-e0d1-46f7-bb61-17587f2863e5">200703240500</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a89acb85-0395-44b1-94c1-cd205ac05a02">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f224d3c-0771-4894-a4d5-f113b9cb0bd5">8001 / 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c489cc7-c76a-432b-a9b2-5e416533d432">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fef5c903-3e45-49ae-babe-d673a57437d5">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111703">(111703, DCM, "Processing step description")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cba14c5-1185-4e7c-b8a3-5fdfaa92d0f9">Embedding (paraffin)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cc89fd1-5021-4919-9af6-5d69f8144e87">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfb99f98-600b-4c05-bc22-3b148a6407c9">8001 / 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d48527b2-6c39-469a-a219-53f29f127940">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42e2983d-e96b-4323-9ca8-24f479bd8cdb">
                                    <link xl:href="http://snomed.info/id/430863003" xl:show="new">(430863003, SCT, "Embedding medium")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ade1ecb-984e-4b77-98e0-a432de33aa65">
                                    <link xl:href="http://snomed.info/id/255667006" xl:show="new">(255667006, SCT, "Paraffin")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="7">
                                <para xml:id="para_ceb24d5f-d3ca-46c1-b42c-29b69d4e7e77">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c18cae9-ae09-4f71-980b-9ff3f6fb9574">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_584da3c9-ca86-4f98-9511-8c185daee413">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c7868d4-68a0-4a73-9a00-9b09f98e0db1">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f104306-d94e-42fa-9696-1333cb315c94">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_070ca49c-b6e5-43b2-b045-62a5f009e8d0">S07-100 A 5 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="7">
                                <para xml:id="para_6fe66002-0a01-4653-bca5-1e41e482a730">Slide Staining</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/434711009" xl:show="new"><emphasis role="bold"><emphasis role="underline">(434711009, SCT, "Specimen container")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/433466003" xl:show="new"><emphasis role="bold"><emphasis role="underline">(433466003, SCT, "Microscope slide")</emphasis></emphasis></link>
                        </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 2b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/371439000" xl:show="new"><emphasis role="bold"><emphasis role="underline">(371439000, SCT, "Specimen type")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/1179252003" xl:show="new"><emphasis role="bold"><emphasis role="underline">(1179252003, SCT, "Slide")</emphasis></emphasis></link>
                        </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1c815f7-206f-45bb-a369-58d402888fe4">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_164ade27-257b-4d02-9db7-abbe75700ec1">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6b09ddb-ce2f-4f2c-91a9-fd2cf6804de3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af23e1fb-3718-40fe-8940-d29e8a44fdfd">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dd5cf82-3329-4f3f-9ede-bb28b9c1cf69">
                                    <link xl:href="http://snomed.info/id/127790008" xl:show="new">(127790008, SCT, "Staining")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0c6fe8b-faef-4486-a426-e1ebf307068b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcd8f694-81c3-4584-aabc-6e0ae2b7628f">8001 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0208be4c-f9bf-4b77-a2a8-31312adc230c">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f644c8e-7973-4234-95ce-06d8a4f32cbb">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111702">(111702, DCM, "DateTime of processing")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e294da9f-08c3-4fe0-9100-32160fab9d7b">200703240700</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37b64ad8-b911-4b34-baef-f367a12c3af6">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8907d92d-d5ab-483c-b96a-c6b3e615c1f3">8001 / 9</para>
                                <para xml:id="para_85f0aaff-e78f-4d9e-9793-0e229c4dce3b">8003 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8420dcbd-0e22-4acd-91e1-d9cf8f7c9178">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a5ee542-7333-4f60-b31a-1ba69f80da44">
                                    <link xl:href="http://snomed.info/id/424361007" xl:show="new">(424361007, SCT, "Using substance")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b821850b-0625-412e-8bc6-2ecbb718e16b"><link xl:href="http://snomed.info/id/12710003" xl:show="new">(12710003, SCT, "hematoxylin stain")</link></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>8001 / 9</para>
                                <para>8003 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <link xl:href="http://snomed.info/id/424361007" xl:show="new">(424361007, SCT, "Using substance")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><link xl:href="http://snomed.info/id/36879007" xl:show="new">(36879007, SCT, "water soluble eosin stain")</link></para>
                            </td>
                        </tr>
                    </tbody>
                </table>

        
        
    
        

    </chapter>
</book>
