<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-nnnn</title>
    <subtitle>Add keywords for Context Groups in PS3.16</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Submitted</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2021/10/20</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2021/10/20</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-nnnn</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add keywords for Context Groups in PS3.16</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>FHIR resources that are copies of DICOM PS3.16 Context Groups contain a keyword attribute that is also used in the filename of the resource.</para>
                    <para>This needs to be predictable, not subject to the vagaries of automated generation from the Context Group section/table title as is currently done,
                        and preferably follow similar rules as other keywords in DICOM (including capitalization of conjunctions).</para>
                    <para>Programmatically, toolkits, services and APIs that support management of DICOM Context Groups would also be well served by having standard keywords even if they were not using standard representations of resources or files instantiating Context Group content.</para>
                    <para><emphasis role="italic">[Ed.Note: One form of keyword proposed is of the form "dicom-cid-n-XXX" where n is the CID and XXX is derived from the text of the title with special characters and white space removed, etc. This is what is used for the "keyword" element in the FHIR resource. This is different from other keywords in DICOM (such as for data elements and UIDs, which omit the system (dicom) and the scope (cid) and just include the name. That would work too, since the FHIR keyword could be constructed unambiguously from such an unscoped entry. Alternatively both could be explicitly specified, as is illustrated in the current draft.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Once complete, updated FHIR JSON and XML resource URLs to use keyword rather than current default,
                        e.g., ValueSet-dicom-cid-6007-CharacteristicsOfMarginFromBIRADS instead of ValueSet-dicom-cid-6007-CharacteristicsofMarginfromBIRADS.]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.16 as follows, according to this pattern:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        <section label="CID 2" status="3" xml:id="sect_CID_2">
            <title>Anatomic Modifier</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f79bfe2d-c731-462b-bc87-562511d7f00e">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_2.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-2-AnatomicModifier.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-2-AnatomicModifier.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold"><emphasis role="underline">Keyword:</emphasis></emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold"><emphasis role="underline">AnatomicModifier</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold"><emphasis role="underline">FHIR Keyword:</emphasis></emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold"><emphasis role="underline">dicom-cid-2-AnatomicModifier</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_49fff8bd-28af-4b8e-8147-3f6a707881c2">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1f9d5e1e-e22c-4c79-9334-d0fc855fb49e">
                            <emphasis role="bold">20190118</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_01f68e19-ed20-4d72-9402-1d4703778571">
                            <emphasis role="bold">1.2.840.10008.6.1.1</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            
        </section>
        
        <section label="CID 65" status="3" xml:id="sect_CID_65">
            <title>Pre-medication For Imaging Agent Administration</title>
            <para xml:id="para_7ef066e9-d1ce-4539-9c55-bfd96e7340b7">The following list of pre-medication agents was obtained from the ACR Manual of Contrast Media.</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_3cd36025-5649-46bb-8a96-2c6a8dc7813a">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_65.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-65-PremedicationForImagingAgentAdministration.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-65-PremedicationForImagingAgentAdministration.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1255.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold"><emphasis role="underline">Keyword:</emphasis></emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold"><emphasis role="underline">PreMedicationForImagingAgentAdministration</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold"><emphasis role="underline">FHIR Keyword:</emphasis></emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold"><emphasis role="underline">dicom-cid-65-PreMedicationForImagingAgentAdministration</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_23ee2508-ebd5-4284-9a70-6bae05ff6cfa">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1b1d8d16-421d-4688-9029-df7512c95fe3">
                            <emphasis role="bold">20190817</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_2dc7931c-38c7-480a-859c-59dd6d47b136">
                            <emphasis role="bold">1.2.840.10008.6.1.1255</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
        </section>
    
        <section label="CID 6007" status="3" xml:id="sect_CID_6007">
            <title>Characteristics of Margin from BI-RADS®</title>
            <note>
                <para xml:id="para_6b895c9b-2928-4d35-a015-10633c5b82dc">From BI-RADS®</para>
            </note>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_15cc18bb-77c7-40b0-9b02-d915287fcfa1">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6007.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-6007-CharacteristicsofMarginfromBIRADS.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-6007-CharacteristicsofMarginfromBIRADS.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.337.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold"><emphasis role="underline">Keyword:</emphasis></emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold"><emphasis role="underline">CharacteristicsOfMarginFromBIRADS</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold"><emphasis role="underline">FHIR Keyword:</emphasis></emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold"><emphasis role="underline">dicom-cid-6007-CharacteristicsOfMarginFromBIRADS</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ecab4036-d687-4a84-9809-1698ad5adb9f">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_46fbbf84-fb02-45c2-9f65-5efe0de485a1">
                            <emphasis role="bold">20050822</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_fb3396f3-06f0-4060-aa72-8b84c24bc768">
                            <emphasis role="bold">1.2.840.10008.6.1.337</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
        </section>

    </chapter>
</book>