<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-2179</title>
    <subtitle>Add Pathology Annotation Codes</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2021/11/14</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>Markus Daniel Herrmann <link
            xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:MDHERRMANN@MGH.HARVARD.EDU"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>2021/10/17</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2179</para></td>
    </tr>
    <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Pathology Annotation Codes</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
          <para>PS3.16, PS3.17</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Rationale for Correction:</para>
          <para>Additional context groups and concepts are needed for slide microscopy image annotations. Specifically:</para>
          <itemizedlist>
              <listitem>
                  <para>For Anatomical structure (histology) – using SNOMED-CT body structure or cell structure – possibly for inclusion into CID 7192 "Anatomical Structure Segmentation Property Types".</para>
                  <itemizedlist>
                      <listitem>
                          <para>new CID XXXA1 "Tissue Structure" (connective tissue, epithelium, basal membrane, etc.)</para>
                      </listitem>
                      <listitem>
                          <para>new CID XXXA2 "Cell Structure" (cell, nucleus, mitochondrium, etc.) ??? reuse or rename Sup 222 CID 8135 "Microscopy Annotation Property Types" (not currently referenced)</para>
                      </listitem>
                  </itemizedlist>
              </listitem>
              <listitem>
                  <para>Morphologically Abnormal Structure (histopathology) – SNOMED-CT finding or morphologic abnormality (but not disorder) – possibly for inclusion into CID 7194 "Morphologically Abnormal Structure Segmentation Property Types".</para>
                  <itemizedlist>
                      <listitem>
                          <para>new CID XXXM1 "Epithelial Tumor Structure" (adenocarcinoma, squamous cell carcinoma, adenoma, etc.)</para>
                      </listitem>
                      <listitem>
                          <para>new CID XXXM2 Connective Tissue Tumor Structure" (leiomyosarcoma, liposarcoma, chondroma, etc.)</para>
                      </listitem>
                  </itemizedlist>
              </listitem>
          </itemizedlist>
          <para>Also, add examples in new informative Annex for PS3.17.</para>
          <para><emphasis role="italic">[Ed.Note: TBD. In examples, is it good practice to include generic type of neaoplasm, and modifier with more specific type, e.g., adenocarcinoma, or should the specific type be illustrated as adenocarcinoma without a modifier (and the recipient expected to have an ontology if they care to recognize that adenocarcinoma are neoplasms..]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Examples are predicated on separate CP "Add Category of Finding to TID 1500".]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note. Examples are predicated on separate CP "Add Anatomy to Microscopy Bulk Simple Annotations".]</emphasis></para>
          <para><emphasis role="italic">[Ed.Note: TBD. Is it necessary to explicitly code in SR examples the Associated Topography, ot since this replicates Finding Site, should instead be mentioned tindescription of Finding Site.]</emphasis></para>
          <para><emphasis role="italic">[Ed.Note: SNOMED CRS Request ID# for additional concepts in DICOM subset.]</emphasis></para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>
    <section>
      <title></title>
        
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Amend DICOM PS3.16 as follows:</emphasis></para></td></tr>
      </informaltable>

        <section label="CID 7192" status="3" xml:id="sect_CID_7192">
            <title>Anatomical Structure Segmentation Property Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_dbf185e1-8810-4bd1-854b-09f43f3346a5">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7192.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7192.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7192.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1191.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d098bbb3-5a91-4176-80b3-a1e2d03f6d8b">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_34b12ae7-7a8e-40c9-adfb-131d77e341ed">
                                <emphasis role="bold"><emphasis role="strikethrough">20170914</emphasis><emphasis role="underline">yyymmdd</emphasis></emphasis>
                            </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ab4be288-98c0-41b5-ab3d-95bd8c63217d">
                            <emphasis role="bold">1.2.840.10008.6.1.1191</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7192" rules="all" xml:id="table_CID_7192">
                <caption>Anatomical Structure Segmentation Property Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21a96aa5-0e2f-4df9-8759-28980473fae5">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a27ffb2c-bdc9-42fa-96a6-a93567b19872">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2c01df9-4aed-4dc6-b3f4-12786d6a1288">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_425c8ed7-ee63-4fde-a631-01e81c13b2a0">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2efbded0-c32f-458f-b901-a24673b224d3">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_14ef616a-94da-4569-88b5-d0ac1c8634d9">
                                <emphasis role="italic">Include <xref linkend="sect_CID_4" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_c5db7615-7291-4b8d-8497-d9e7df89ed54">
                                <emphasis role="italic">Include <xref linkend="sect_CID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_491ed758-150c-44c2-9133-423553ce32dc">
                                <emphasis role="italic">Include <xref linkend="sect_CID_3827" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_513ecfc9-2e43-48ca-9968-3f31d39b43bb">
                                <emphasis role="italic">Include <xref linkend="sect_CID_3829" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_8ac7d7ee-a34b-4a2d-b273-329ee07b5a54">
                                <emphasis role="italic">Include <xref linkend="sect_CID_4028" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_18694c72-2159-4a3f-a625-0dab7c5db687">
                                <emphasis role="italic">Include <xref linkend="sect_CID_4030" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_5a057d8a-e9da-46b7-99e6-7b8cad48c66b">
                                <emphasis role="italic">Include <xref linkend="sect_CID_4040" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_7d9ad3f5-2094-45ad-bdfc-6fa2ff3f4beb">
                                <emphasis role="italic">Include <xref linkend="sect_CID_6110" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_c5c28cd4-7c4b-490e-b836-71f50c40343c">
                                <emphasis role="italic">Include <xref linkend="sect_CID_6111" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_3181556e-013b-4a1e-910c-8363c9a7f982">
                                <emphasis role="italic">Include <xref linkend="sect_CID_6112" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_0f00c06b-3685-4952-b62b-0aecd5d302e0">
                                <emphasis role="italic">Include <xref linkend="sect_CID_6113" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_f453a1bd-a7ae-418d-8fa7-67c035f56d8b">
                                <emphasis role="italic">Include <xref linkend="sect_CID_6114" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_46b20a38-3177-4eef-a399-09aeaa3eb3e3">
                                <emphasis role="italic">Include <xref linkend="sect_CID_6116" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_61b1af06-830c-4078-9a3c-2554cd388c0b">
                                <emphasis role="italic">Include <xref linkend="sect_CID_6117" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_df36db4d-881b-4ba3-93d5-ebb3df76a2d9">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7152" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_628eb0ca-a4dc-4a91-b37b-43beedf6d69a">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7153" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_6ece6b66-1a01-4f4a-a2e1-77df977bb726">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7154" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_64a5ca60-8f2c-4677-aa15-c4687330ee9e">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7155" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_a70a1877-aed9-4867-a0e0-2221d174b8e2">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7156" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_92539b6b-0392-4c11-8270-782cc4079bd7">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7160" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_1a829a3c-30de-4782-81ec-fc8c6a6d784b">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7167" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_682440b9-2dfd-4c90-b610-087e095da92d">
                                <emphasis role="italic">Include <xref linkend="sect_CID_4273" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_XXXA1" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_XXXA2" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 7194" status="3" xml:id="sect_CID_7194">
            <title>Morphologically Abnormal Structure Segmentation Property Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_26b362c3-b2ad-4e24-9d20-99b75e8fae37">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7194.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7194.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7194.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1193.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_e31fe5ce-2f45-4d02-962d-809df26fb59a">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a5c6c063-4280-4642-8c39-c6ee94b12434">
                            <emphasis role="bold"><emphasis role="strikethrough">20170914</emphasis><emphasis role="underline">yyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_3a2a1722-f2bd-4941-9b05-3ca491357236">
                            <emphasis role="bold">1.2.840.10008.6.1.1193</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7194" rules="all" xml:id="table_CID_7194">
                <caption>Morphologically Abnormal Structure Segmentation Property Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6736f0d7-1cee-4e88-8c00-9f0210fff097">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2f3dcf3-8c60-473c-aa0c-6e76c217ee18">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa317fb5-789d-4afa-aabc-912fd00a93ae">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_07801d49-167b-4708-b5d2-22eddadacec3">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2912ff2-2199-4254-89f8-9522b56fa30f">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_acd6515d-811f-4f73-ae61-0a5eef1a57ec">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7159" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_XXXM1" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_XXXM2" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="CID 8135" status="3" xml:id="sect_CID_8135">
            <title>Microscopy Annotation Property Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_dec801b3-34a1-4dff-a94c-35fd34bf3b74">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8135.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_8135.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_8135.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1365.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_9333dd8d-457b-4e24-95d7-5ebe8b85dea8">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_27cc6645-76c1-42f4-83ed-0f9d7a18cfc9">
                            <emphasis role="bold">20210712</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_44f17f95-f1cd-447a-9fc4-f7849df3bbcd">
                            <emphasis role="bold">1.2.840.10008.6.1.1365</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8135" rules="all" xml:id="table_CID_8135">
                <caption>Microscopy Annotation Property Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1f27f6c9-a329-4684-85e8-93f2405045ed">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5893144e-8e04-4742-8ec1-cbdf9a59ea35">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d605e56c-b60c-4d8c-a120-027174e8ef47">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d32bf707-223c-4ab1-bcf7-7a0a309b078a">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6013269-0625-43cc-991a-5acac6ce6172">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ded66c4-c1be-4d8d-b1b6-d6b7d65fb6da">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89797cf7-1ed3-4817-8345-a379bf0298f9">
                                <link xl:href="http://snomed.info/id/4421005" xl:show="new">4421005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f40a3495-3c32-4c95-b8d7-125b31bf008c">Cell</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b5d49e59-640e-407b-a1a6-f16e95ff0234">
                                <link xl:href="http://snomed.info/id/4421005" xl:show="new">T-E0000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d4a7141-353e-413c-976d-55adb26f30a7">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007634" xl:show="new">C0007634</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e067a369-cbe7-4f0a-beab-4695a271fd44">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a61127df-05ab-4089-8c5a-0a2328817ba3">
                                <link xl:href="http://snomed.info/id/84640000" xl:show="new">84640000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f6b2b3a4-70bf-48d6-b888-71af064ed5a0">Nucleus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_43ac3059-bab3-4877-a680-f0323b96c086">
                                <link xl:href="http://snomed.info/id/84640000" xl:show="new">T-E0100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e05edc55-3154-453e-bd26-a0564bc98094">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007610" xl:show="new">C0007610</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        <informaltable rules="all" frame="box">
            <tr><td><para><emphasis role="italic">Add new Context Gropus to DICOM PS3.16 as follows:</emphasis></para></td></tr>
        </informaltable>
        
        <section label="CID XXXA1" status="3" xml:id="sect_CID_XXXA1">
            <title>Tissue Structure Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_XXXA1.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_XXXA1.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_XXXA1.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.UUUA1.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.UUUA1</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID XXXA1" rules="all" xml:id="table_CID_XXXA1">
                <caption>Tissue Structure Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/21793004" xl:show="new">21793004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Connective tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/21793004" xl:show="new">T-1A200</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0009780" xl:show="new">C0009780</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID XXXA2" status="3" xml:id="sect_CID_XXXA2">
            <title>Cell Structure Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_XXXA2.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_XXXA2.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_XXXA2.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.UUUA2.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.UUUA2</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID XXXA2" rules="all" xml:id="table_CID_XXXA2">
                <caption>Cell Structure Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/4421005" xl:show="new">4421005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Cell</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/4421005" xl:show="new">T-E0000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007634" xl:show="new">C0007634</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/84640000" xl:show="new">84640000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Nucleus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/84640000" xl:show="new">T-E0100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007610" xl:show="new">C0007610</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID XXXM1" status="3" xml:id="sect_CID_XXXM1">
            <title>Epithelial Tumor Structure</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_XXXM1.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_XXXM1.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_XXXM1.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.UUUM1.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.UUUM1</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID XXXM1" rules="all" xml:id="table_CID_XXXM1">
                <caption>Epithelial Tumor Structure</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/35917007" xl:show="new">35917007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Adenocarcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/35917007" xl:show="new">M-81403</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0001418" xl:show="new">C0001418</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID XXXM2" status="3" xml:id="sect_CID_XXXM2">
            <title>Connective Tissue Tumor Structure</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_XXXM2.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_XXXM2.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_XXXM2.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.UUUM2.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.UUUM2</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID XXXM2" rules="all" xml:id="table_CID_XXXM2">
                <caption>Connective Tissue Tumor Structure</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/51549004" xl:show="new">51549004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Leiomyosarcoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/51549004" xl:show="new">M-88903</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0023269" xl:show="new">C0023269</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <informaltable rules="all" frame="box">
            <tr><td><para><emphasis role="italic">Add new Informative Annex to DICOM PS3.17 as follows:</emphasis></para></td></tr>
        </informaltable>
        
        <section label="XXXX" status="1" xml:id="XXXX">
            <title>Anatomic Pathology Whole Slide Image Annotation (Informative)</title>
            <section label="XXXX.1" status="2" xml:id="sect_XXXX.1">
                <title>Examples of Coding Tumor Morphology and Topography (Primary Site)</title>
                <section label="XXXX.1.1" status="2" xml:id="sect_XXXX.1.1">
                    <title>In Structured Reports</title>
                    <para>(276214006, SCT, "Finding category") = (49755003, SCT, "Morphologically Abnormal Structure")</para>
                    <para>(121071, DCM, "Finding") = (108369006, SCT, "Neoplasm")</para>
                    <para>(363698007, SCT, "Finding Site") = (39607008, SCT, "Lung")</para>
                    <para>(116676008, SCT, "Associated Morphology") = (35917007, SCT, "Adenocarcinoma") - ??? should we add a Finding Modifier instead to parallel SEG/ANN pattern</para>
                    <para>(116677004, SCT, "Associated Topography") = (39607008, SCT, "Lung") - ??? this is redundant with Finding modifier</para>
                 </section>
                <section label="XXXX.1.2" status="2" xml:id="sect_XXXX.1.2">
                    <title>In Segmentations</title>
                    <para>Segmented Property Category Code Sequence (0062,0003) = (49755003, SCT, "Morphologically Abnormal Structure")</para>
                    <para>Segmented Property Type Code Sequence (0062,000F) = (108369006, SCT, "Neoplasm")</para>
                    <para>Segmented Property Type Modifier Code Sequence (0062,0011) = (35917007, SCT, "Adenocarcinoma")</para>
                    <para>Primary Anatomic Structure Sequence (0008,2228) = (39607008, SCT, "Lung")</para>
                </section>
                <section label="XXXX.1.3" status="2" xml:id="sect_XXXX.1.3">
                    <title>In Bulk Annotations</title>
                    <para>Annotation Property Category Code Sequence (006A,0009) = (49755003, SCT, "Morphologically Abnormal Structure")</para>
                    <para>Annotation Property Type Code Sequence (006A,000A) = (108369006, SCT, "Neoplasm")</para>
                    <para>Annotation Property Type Modifier Code Sequence (006A,000B) = (35917007, SCT, "Adenocarcinoma"), (39607008, SCT, "Lung")</para>
                    <para>Primary Anatomic Structure Sequence (0008,2228) = (39607008, SCT, "Lung")</para>
                </section>
            </section>
        </section>



    </section>
  </chapter>
</book>
