  <title>CP-2176</title>
    <subtitle>Add Category of Finding to TID 1500</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2021/11/14</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>Markus Daniel Herrmann <link
            xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:MDHERRMANN@MGH.HARVARD.EDU"/></para>
        <para>IDC</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>2021/09/05</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2176</para></td>
    </tr>
    <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Category of Finding to TID 1500</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
          <para>PS3.16</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Rationale for Correction:</para>
          <para>There is an inconsistency between SR (TID 1410, 1411, and 1501) and segmentations (SEG) and annotations (ANN). For SEG/ANN, one is required to specify the property category and type, while in SR one can only specify (121071, DCM, "Finding"), which corresponds to the property type ("finding type") (added in CP 1465).</para>
          <para>There is no template row to specify the finding category. This is problematic for at least two reasons:</para>
          <itemizedlist>
              <listitem>
                  <para>It complicates interpretation, compared to what is possible with the SEG. E.g., is the category of a finding a normal anatomic structure or a morphologic abnormality?</para>
              </listitem>
              <listitem>
                  <para>When providing additional ROI measurements of referenced segments, information about the category (from the SEG) is not communicated.</para>
              </listitem>
          </itemizedlist>
          <para><emphasis role="italic">[Ed.Note: The existing SCT code 276214006 (with the FSN "Findings category type (qualifier value)"), with the DICOM synonym "Finding category", is used rather than creating a new DCM-specific code. CRS Request ID# 764392.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: TID 1501 uses TID 300, so does not reference segmentations, hence the absence of the comment cross-referencing segmentation-specific attributes; the category concept is still useful and appropriate, however.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note; Should we add default context groups for findingcategories and findings, to match those reference in the PS3.3 uses of Segmented Property Category Code Sequence (0062,0003) and Segmented Property Type Code Sequence (0062,000F), specifically CID 7150 and CID 7151 respectively? Certainly the categories are a short list that are reusable beyond the segmentation role; the segmentation type concepts may be too specific and not sufficient for generic TID 1500 use cases; the categories are tied to specific invocations of segmentation type context groups, however.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Is it not high time we replaced (121071, DCM, "Finding") with a concept from a more generic source that is included in UMLS, e.g., (LA9042-8, LN, "Finding") == (C61036, NCIt, "[Investigation ]Finding") == (C0243095, UMLS, "Finding")? If so, this should be done as a separate CP and generally applied, since it affects many more templates than these.]</emphasis></para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>
    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Amend DICOM PS3.16 as follows:</emphasis></para></td></tr>
      </informaltable>


                    <section label="TID 1410" status="3" xml:id="sect_TID_1410">
                <title>Planar ROI Measurements and Qualitative Evaluations</title>
                <para xml:id="para_47a24b81-ef09-41fc-b6aa-1cd54a1889dd">...</para>
                <table frame="box" label="TID 1410" rules="all" xml:id="table_TID_1410_Parameters">
                    <caption>Parameters</caption>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">...</td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d66def76-9bff-4401-8087-e8ac8d5333bd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">$FindingCategory</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Category of the finding</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ea4ba14-5fde-42b2-a4eb-73fc0f3ecc05">$FindingType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57719c85-9ca2-4dcb-9ee1-50fccf227fa1">Type of the finding</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74d8b5ea-e27b-410a-8891-b7a92fd01592">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db3b4725-36df-4f2c-a3ea-fb0bed91a3c4"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <table frame="box" label="TID 1410" rules="all" xml:id="table_TID_1410">
                    <caption>Planar ROI Measurements and Qualitative Evaluations</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30b4aee0-ea2f-4145-8208-793586b42cc7"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2114728-d791-431b-9191-bc8f10b33fb6">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebe5dfb8-ae20-4bef-910d-06c15730b75b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11076f1d-2653-47e3-867d-98687bcf34d3">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e28dd32-3fea-42af-ba33-fb3836638cf4">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b53dfca1-52dc-4c1a-86ae-6e7da6594631">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdfbf0aa-9607-43d3-8888-66cb7b9ecd25">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98188a1d-f8c2-4703-b93c-1bbbda3c1e56">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4191d21b-4639-4e6b-9acf-3961b18247e2">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bda96106-9fc7-43dd-a450-a91a0a6e6fca">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71a85977-09a6-44a2-8acd-8142481e9370"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_489b564d-d244-477d-bd40-a3039fc941b6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6aa1279-28cf-49b4-9778-3eec192f8b70">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f372076d-6d4d-4f09-bbdc-e10f7d314c85">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6fcff3e-4c4d-4a1d-a7ea-d26a8443c9e3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da8a0eb6-8b06-4635-a02a-cba4d9ce5d6d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71881a64-73b5-48d6-b0b0-fbe9806900be"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07f57d22-61b8-4875-bd89-d3283d0dbdcc"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb0e53f7-4360-4bdc-90f3-8a0eceeb1ef5">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_156f7617-86c4-4f6c-b54b-caf1b3189fbb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_276c3053-b014-48d2-a7a7-55cfc41f878f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41a9d7d3-bf90-4341-8ad3-9837ad16c24f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a7b3a52-1412-4e42-9d2d-0cfa9e7d62a0"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f859274b-a604-4548-87e7-eb0fd5b28d7b"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c455c16d-f3e3-455e-be7f-b95a4ac1edd5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea4722b2-6f7c-4c8e-bb0d-8a806ebab8fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3890255-829a-4c67-ac45-36643d998a30"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61eea44b-9345-4adf-bd2b-da7e4f0cfd3f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6518a43-bd91-477f-8163-22f87ce8399a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3163fac-58ce-4b74-9c4d-ae5b5c3b1c4a">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7eb648d-b8c3-4a65-aea0-241b45a29080">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d75bac53-c1ad-41a2-9c6a-a414c5433710">EV <link linkend="DCM_112040" xrefstyle="select: nopage">(112040, DCM, "Tracking Unique Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc70b867-32f5-4e46-aafc-6b8f9d0de090">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae34cf1e-1f42-4f16-99c9-ab9ad6234a8d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0f122bd-cf31-413e-893f-166a3d9a537b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c54c8c1-09f4-4a16-9006-a14f147d192a">$TrackingUID</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">3a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CONTAINS</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">EV <link xl:href="http://snomed.info/id/276214006" xl:show="new">(276214006, SCT, "Finding category")</link></emphasis></emphasis>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">$FindingCategory</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8764a019-df85-47b1-bc38-1eeac537d7ac">3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da585f62-2c12-4888-8125-d7a6c7e62263">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4ac1cac-ee86-4a86-865a-8137ebe1bd95">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfd59901-9eaf-4594-86b4-d9df83d9972f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_360e0c20-ef41-4422-9ab8-8263e4d3ae4a">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07010f85-ccd1-4d84-bd56-83e480764378">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81d25198-eea2-4721-bfea-3acb1f82456f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46aabbca-0393-4351-9e8d-723c2187ff69"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dc7e2f2-b912-4670-8550-e10372be23c2">$FindingType</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_ec816b00-2bbf-4e9a-a729-6c2563b25135">...</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_53d9f483-05bc-473d-9729-30abe88771a6"/>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_ac2e31c3-79c7-4311-9f39-d601da51e09b"/>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_00d7dcee-a829-48f9-be89-57c073497cce"/>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_5a96f36a-6706-46a2-b5c5-88f0de5adf09"/>
                            </td>
                            <td align="center" colspan="1">
                                <para xml:id="para_124dd689-9d01-4d90-aed8-72524cdd2bfd"/>
                            </td>
                            <td align="center" colspan="1">
                                <para xml:id="para_96f48934-c179-4085-9b02-50a32669d76b"/>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_890d613c-4d02-4ef5-9bb5-c34464f943f2"/>
                            </td>
                            <td align="left" colspan="1"><para/></td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_12f34dea-c5d4-4127-b3fd-5f2adff0a8ef">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65e892e1-ba0e-48e9-943a-c83cbb9853e3">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbf64cb0-8a44-4981-95d9-33e71bf19d91"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_676d3cf2-7665-45d7-8a2e-ead357a99bd7">Rows 2, 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48b5a5c1-401f-4c09-876b-7abed9278926">The Tracking Identifier and Tracking Unique Identifier are defined as a text label or unique identifier (respectively) used for tracking a finding or feature, potentially across multiple reporting objects, over time. As such, they are distinct from the Observation UID (0040,A171), which is unique identifier of the specific Content Item and its subsidiary Content Items that constitute an individual observation, and would be different for different observations on different occasions of the same finding or feature. The values of these content items shall match the corresponding values of Tracking ID (0062,0020) and Tracking UID (0062,0021), if present, in the corresponding Segment of any Segmentation instance referenced in Row 7.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e17b68a-7939-456c-8b99-579be487c98d">Row<emphasis role="bold"><emphasis role="underline">s 3a,</emphasis></emphasis> 3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0f5afd6-90cf-424c-9ab1-9ca35f66c302">The <emphasis role="bold"><emphasis role="underline">category and </emphasis></emphasis>type of the finding describe<emphasis role="bold"><emphasis role="strikethrough">s</emphasis></emphasis> whatever entity (finding or feature) is identified by Rows 2 and 3. E.g., a finding might be a lesion, a tumor, or a reference region (as distinct from its anatomical location, which is encoded in a different content item (Finding Site).<emphasis role="bold"><emphasis role="underline"> When spatial localization is by reference to a Segmentation, the category and type may correspond to the values of Segmented Property Category Code Sequence (0062,0003) and Segmented Property Type Code Sequence (0062,000F), respectively.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c53d2751-c9e1-4f42-b8cb-2db8762be074">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91888c98-d413-40db-985e-f81f83c2ebb0"/>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1411" status="3" xml:id="sect_TID_1411">
                <title>Volumetric ROI Measurements and Qualitative Evaluations</title>
                <para xml:id="para_cbcf130c-59d0-43ea-b71c-7f7d5b19c70b">....</para>
                <table frame="box" label="TID 1411" rules="all" xml:id="table_TID_1411_Parameters">
                    <caption>Parameters</caption>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12bc1135-1528-4f57-af74-985a2a957dcc">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ef5c685-327f-43bc-ab4d-385b2bfdc3cd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">$FindingCategory</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Category of the finding</emphasis></emphasis></para>
                            </td>
                        </tr>                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0fd4697-f42d-4c3f-b519-1710f342e862">$FindingType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b08d0544-14c8-49fe-987b-b61c35159355">Type of the finding</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <table frame="box" label="TID 1411" rules="all" xml:id="table_TID_1411">
                    <caption>Volumetric ROI Measurements and Qualitative Evaluations</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87e5605c-30ef-40ab-9e54-e5a160ac1e4c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b792ca18-4b6b-4780-8c36-f0872b923a62">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4548b0a2-dafe-4ffe-b5ff-6f4b746b5f37">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b48ed64-9046-488b-aaab-3e437093e793">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_037bfccf-fcbf-4646-a614-7d3edd7495e1">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4416f1f-b2da-48e2-afc1-6d1916588c9f">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d7ea4d1-7d0f-4df2-9d64-44c4151c48a8">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c44f7e5-e932-432b-ae62-83dc4ba5d58f">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6daad6dd-d304-4d58-b580-ab3f55ee692f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bd991eb-9642-42a0-9c93-87848af2ac98">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9797c7cc-b481-4eec-8d93-ae08fb873fac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eab96362-2bfa-41eb-9637-0bf9efdfb87c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bcea660-1791-4428-9783-86bf458b9f04">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2b51594-f8ef-4ee7-8448-f3dfaa51b3a9">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8912904-0922-489a-85ba-f80c0b80db5e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06cf9952-1268-4f7b-a9fe-915d8d26cd3c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91c8a03f-d2c8-4731-b118-5c6353303797"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac09d88a-4385-4f34-9717-b507f6b6dc0e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_877bb76f-4c64-41b3-bfab-0eea84a49504">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b700d29-3e4b-4bd9-bd54-da1cbfda3b27"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_939f9e7a-0ff4-45cd-be67-8501659ec0a1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c2a24f6-d223-4764-9bc5-f445a2517571"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4e1a46f-5ec2-439f-8ac6-82a7ec89529f"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bf8ef93-0eec-4a8d-a65d-95d52d0bb5a7"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ecb62e6-4ce5-4d1a-9602-fd6d1a6f2b53"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e1259d1-10b4-4705-822c-766dcb020a35"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eda1d8ee-c6de-417f-ab61-06a118c97fd2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf74cec9-f15f-438d-9dd4-a885feb024c1">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0559edc8-3c87-43df-add8-def43d9014b7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81a22fff-1270-40ec-882c-448005cc4a4f">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5ce8862-5514-4f83-945e-5b8e56055553">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea3123b4-9fae-472b-b922-d585a7764e0a">EV <link linkend="DCM_112040" xrefstyle="select: nopage">(112040, DCM, "Tracking Unique Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_748cfd62-5864-4587-aa83-af2a2740a5cb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c36bd25f-4297-4bb2-a529-31cdd7442342">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc703b24-b317-424a-999e-d746c19d966e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91566137-769b-4552-bc4a-be670b7d455d">$TrackingUID</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">3a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CONTAINS</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">EV <link xl:href="http://snomed.info/id/276214006" xl:show="new">(276214006, SCT, "Finding category")</link></emphasis></emphasis>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">$FindingCategory</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_920b74c4-855e-47b7-84ce-0920ae970626">3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcf02cf5-a072-4884-a248-4fe807755965">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dbb8ab4-5274-4fe3-964f-d75547c0548b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5024bb8e-45db-468d-8e23-91ebb51db0f3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a12b91cd-78a7-4cea-80bf-f9da3f99f2ac">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_624ea517-02f8-46d1-8020-204497b41eb8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_107515d3-d48d-46bc-822b-4ac1adf5269e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5064a512-9d40-4dab-ba88-e5b4ff674e97"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b1655ce-a87e-481f-b815-42f7ee423074">$FindingType</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_27a9c34a-fcae-4ed8-8732-afb5e81e5a32">...</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_d4807728-76ac-43df-b946-1135aa8eff4a">&gt;</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_8a82726e-ef2a-4c3c-9e63-df33c70ca466">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_e248355d-0f8e-4ed7-9419-3f6bd509c337">CODE</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_c7eff386-fd52-4799-8e97-ecea7805338c">EV <link linkend="DCM_130400" xrefstyle="select: nopage">(130400, DCM, "Geometric purpose of region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1">
                                <para xml:id="para_4475a4af-fca2-40bb-92bb-335400817776">1</para>
                            </td>
                            <td align="center" colspan="1">
                                <para xml:id="para_ef0bb4c3-bb91-4929-98a9-5aa160f8390d">U</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_600181dd-395e-410b-b039-a89e7984ca3d"/>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_c23c0a68-48b6-40e9-ae52-b1312ef836dd">B<xref linkend="sect_CID_219" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_b60fecd1-f50d-462d-ba6a-1c914b17ae75">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98364871-818d-44d3-a6f0-ef67074f001b">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b73102a7-f750-481b-be22-11897e50d2bf"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dafae3b5-f47f-41cd-a930-6538f8379303">Rows 2, 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa55f4b1-10ac-48b8-82b3-633aaa9b08fc">The Tracking Identifier and Tracking Unique Identifier are defined as a text label or unique identifier (respectively) used for tracking a finding or feature, potentially across multiple reporting objects, over time. As such, they are distinct from the Observation UID (0040,A171), which is unique identifier of the specific Content Item and its subsidiary Content Items that constitute an individual observation, and would be different for different observations on different occasions of the same finding or feature. The values of these content items shall match the corresponding values of Tracking ID (0062,0020) and Tracking UID (0062,0021), if present, in the corresponding Segment of any Segmentation instance referenced in Row 7.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb0af1a7-e4ba-410b-b63c-a73919ca01e8">Row<emphasis role="bold"><emphasis role="underline">s 3a,</emphasis></emphasis>  3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ff69ac9-4f87-41e5-bc56-02182bb54e8e">The <emphasis role="bold"><emphasis role="underline">category and </emphasis></emphasis>type of the finding describe<emphasis role="bold"><emphasis role="strikethrough">s</emphasis></emphasis> whatever entity (finding or feature) is identified by Rows 2 and 3. E.g., a finding might be a lesion, a tumor, or a reference region (as distinct from its anatomical location, which is encoded in a different content item (Finding Site).<emphasis role="bold"><emphasis role="underline"> When spatial localization is by reference to a Segmentation, the category and type may correspond to the values of Segmented Property Category Code Sequence (0062,0003) and Segmented Property Type Code Sequence (0062,000F), respectively.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_fa1588d5-c0b0-4ae6-8a21-dd4e203ad93b">...</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_5b259016-1702-407a-b89e-f8937befa83e"/>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>

<section label="TID 1501" status="3" xml:id="sect_TID_1501">
                <title>Measurement and Qualitative Evaluation Group</title>
                <para>...</para>
                <table frame="box" label="TID 1501" rules="all" xml:id="table_TID_1501_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3aed916a-5ecd-4156-864c-342338106c58">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10711228-3f87-414f-adee-cb3b75652b81">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">...</td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a5e95a1-bc37-4997-88aa-cf5b64863b8d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">$FindingCategory</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Category of the finding</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2e6781e-d015-4b25-836e-ed3b007634f4">$FindingType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4abf161f-5742-4eba-8593-3031d8c0b706">Type of the finding</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3185e69-d385-40be-9d6d-0098f450efa9">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb9be0ef-447b-49c3-995a-55e383d4f6c5"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <table frame="box" label="TID 1501" rules="all" xml:id="table_TID_1501">
                    <caption>Measurement and Qualitative Evaluation Group</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6cf3eeee-bde3-41f2-9cd2-d2a7c2fd15de"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a753304a-333e-44a2-b1de-6a357d827b35">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b361704-3515-44f8-bc8d-8b4c7bbd3bd6">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f88f263-0608-4fda-9eb2-629f8f00ab90">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_472206d9-066c-4c71-9bbd-2114d729f75b">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8720acfb-54df-451c-b098-dc55f146f6bd">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_789f5c1b-14da-47e9-8b2d-91afa2c9f6ce">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e618c06c-2ed8-4cc8-86d8-570049b0290b">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50c97dbc-38b3-4780-8666-e80d0e960f39">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e553294-3b91-4308-9dd5-cab5993fc271">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c32e330b-8290-4360-a024-2bf2bd867a5a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7999f1a1-e780-4573-be47-540a1718b75b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b3f4a25-408c-4c4d-8be6-1d600c149895">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cc549fc-754a-4eaa-a2d3-6291e8750353">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fcc4ffad-bb0d-49ad-b7fa-967199743ff2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b73d3ca3-05ba-48ac-9eab-b2f0e7f0df78">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d35f0bc7-9294-4136-b82c-6d7c23f702b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03be1fcd-9618-44fa-a630-706e645c6bf3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff2f07db-7c32-467f-bb12-fe971b409b38">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a520a91-4690-4471-b566-ea4eb14543a2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8115766b-050b-4d5d-852f-e4e581690f79"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f646f123-7cea-4bca-a381-029fde6fc59a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddaa1d32-2d8c-4385-ba25-45d27dfc1f25"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ae01147-d156-41b1-b8cf-80bae1934d65"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_023d7269-c7d0-45a6-a134-2c3f9b57a170"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32313350-d035-44c7-a8fc-f965aee4cbf2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c95f2e03-ddbc-422c-a9cb-5b0e4fc1c254">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da5e6932-bf43-44a4-938e-ac0c4b59398e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab41450b-9a57-44b3-a073-5189b9a1a7e7">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a1db4e4-6c27-4a6d-899e-84e3b03c4909">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86f7fc17-109b-4be9-b280-75e7ff74bf08">EV <link linkend="DCM_112040" xrefstyle="select: nopage">(112040, DCM, "Tracking Unique Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89fbfd41-6a43-4dab-bf53-300d3424bb25">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b73b7f0f-b17f-4f69-b42f-fc99b82a8053">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79b85cb5-6190-4869-ab85-fcfd27f5f661"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0aae53a9-4e88-4004-b47d-4f60ea6e939e">$TrackingUID</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">3a</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CONTAINS</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">EV <link xl:href="http://snomed.info/id/276214006" xl:show="new">(276214006, SCT, "Finding category")</link></emphasis></emphasis>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">$FindingCategory</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9763279f-53e8-43d1-93fb-258bb884ecd4">3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac4af6c3-1dcc-4524-8692-d4695beb2066">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd27ece4-d1f8-4748-8a12-89a095d269da">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3dff116-887c-4d97-8e6d-0778055cfb5a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba69039d-644a-4d45-80ee-6671449d6a6c">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_649c608f-4175-4b85-a096-755a335e4d50">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29ae51ab-d234-4bc1-bf27-1f8dc7e556fa">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cca1812a-ebe6-4087-bb4e-5229dac621b7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67353bf7-139b-420c-89d2-1e6f09417848">$FindingType</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22e44b23-abc9-45af-9498-597a62ef13cf">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cc64775-2655-4f1e-80b9-533bc6a4890b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c8f186e-bdec-4cad-9d7f-ef02fed767c6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46d1d522-0ecb-4608-8c37-a43d6482f14a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a792ad4d-8aa9-470c-9cea-a5731f1a4443"></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89a7b9c0-3c88-43b8-82ee-3e6589c7fbc8"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71ef31a4-9567-4dfa-a1b8-2d601cf8d07c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dd345d9-6f9c-4e7e-9958-6ca13d3bf742"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94bcaef0-dbfd-43bc-9386-fbf03ef452ba"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_c6830046-1dab-4cc0-aaf8-fd119bd48c1e">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96280a7d-623e-4e89-a8a0-fd292a80eecc">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e69cade8-84bc-4519-8b50-52ce0104173d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_626354d7-f51a-46ac-9117-d6e798d955c3">Rows 2, 3, 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8cda662-f6a6-48e6-b639-993d5d10a3fc">The included TID 300 contains an optional inclusion of TID 1408 Tracking Identifier as a child of the NUM measurement, which in turns allows for either or both Tracking Identifier and Tracking Unique Identifier Content Items; the intent of Rows 2 and 3 is not to send these Content Items twice, but rather to factor them out into a common location for multiple measurements, and to be consistent with TID 1410 and TID 1411.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c6031d1-d1d8-49c2-ac8e-4edb0e12cbb8">Row<emphasis role="bold"><emphasis role="underline">s 3a,</emphasis></emphasis> 3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_677438e3-51dc-4c5c-be25-4ee955801807">The <emphasis role="bold"><emphasis role="underline">category and </emphasis></emphasis>type of the finding describe<emphasis role="bold"><emphasis role="strikethrough">s</emphasis></emphasis> whatever entity (finding or feature) is identified by Rows 2 and 3. E.g., a finding might be a lesion, a tumor, or a reference region (as distinct from its anatomical location, which is encoded in a different content item (Finding Site).</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_d3de4176-5cc8-4b45-8203-27a4bd55e6c9">...</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_a991a0a9-5062-4554-8f32-188e6058d31b"/>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        
        <section label="G" status="1" xml:id="chapter_G">
            <title>English Code Meanings of Selected Codes (Normative)</title>
            <table frame="box" label="G-1" rules="all" xml:id="table_G-1">
                <caption>English Code Meanings of Selected Codes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37309cee-1fc3-4a9c-94ea-8ef8cdbaa5bb">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_149479f8-a549-4f0a-a8ed-d301cfbe996b">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a650cc21-6a0a-4bce-8340-4c616facbb36">Code Meaning</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="2">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="2">
                            <para>
                                    <link xl:href="http://snomed.info/id/276214006" xl:show="new"><emphasis role="bold"><emphasis role="underline">276214006</emphasis></emphasis></link>
                                </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Finding category</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Findings category type</emphasis></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
                
        
        
        
        

        
        
        
        

        
                 
      
      
       
        
        
        
        
        
    </section>
  </chapter>
</book>