<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-2167</title>
    <subtitle>Add more brain segmentation labels</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>January 2022 Voting Packet</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2021/11/14</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
            xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>2021/07/24</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2167</para></td>
    </tr>
    <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add more brain segmentation labels</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
          <para>PS3.16</para>
      </td>
    </tr>
    <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para>
                    <para>Some more labels are needed for labelling the output of neuroimaging tools, some of which are more specific than currently present, and others of which are not actual brain structures but are outputs of the process.</para>
                    <para>For the concept of "Non-brain", have supplied a more generic "Tissue not of interest" concept, which will suffice in context and be reusable for other organs.</para>
                    <para>See, for example: <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://bids-specification.readthedocs.io/en/stable/05-derivatives/03-imaging.html#common-image-derived-labels"/></para>
                    <para><emphasis role="italic">[Ed.Note: CRS Request ID#nnnnn for 301766008; request new codes for FMA 223151]</emphasis></para>
                </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>
    <section>
      <title></title>
        <informaltable rules="all" frame="box">
            <tr><td><para><emphasis role="italic">Add new Context Group to DICOM PS3.16 as follows:</emphasis></para></td></tr>
        </informaltable>
        
        <section label="CID cccc1" status="3" xml:id="sect_CID_cccc1">
            <title>Anatomically Localized Lesion Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_cccc1.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_cccc1.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_cccc1.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu1.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                                <emphasis role="bold">yyyymmdd</emphasis>
                            </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uuu1</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID cccc1" rules="all" xml:id="table_CID_cccc1">
                <caption>Anatomically Localized Lesion Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/301766008" xl:show="new">301766008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Lesion of Brain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/301766008" xl:show="new">F-A004A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0221505" xl:show="new">C0221505</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr><td><para><emphasis role="italic">Amend DICOM PS3.16 as follows:</emphasis></para></td></tr>
        </informaltable>
        
        <section label="CID 7140" status="3" xml:id="sect_CID_7140">
            <title>Brain Structures for Volumetric Measurements</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d81798c6-65ef-4ed3-a68e-f92eb3c72e78">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7140.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7140.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7140.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.967.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_36face7e-90ba-4f81-96aa-3f47b61beacf">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c5b7521c-60da-4fbc-90cb-1fb33c9c889b">
                                <emphasis role="bold"><emphasis role="strikethrough">20210328</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                            </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_b0e5191e-1862-4cae-b156-b24a9fd2e131">
                            <emphasis role="bold">1.2.840.10008.6.1.967</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7140" rules="all" xml:id="table_CID_7140">
                <caption>Brain Structures for Volumetric Measurements</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87b0a399-dfe7-4115-b068-15ceae33568f">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c6ed55a-ddb1-4626-9840-51c46a3c81a9">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d078468-c5cc-4a57-ac10-69879ef1b21a">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9fbcbe0-f817-41a1-ba97-8ecdaa2b9c9a">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22b3752b-a69e-428b-95a2-fec9c6bbdf4a">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_429f2bb9-9229-4fe6-a48b-30e76bf1e6d7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec21e06a-71ec-4867-860f-73c68e9e1283">
                                <link xl:href="http://snomed.info/id/4958002" xl:show="new">4958002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f6a1daf8-bff1-44e5-9a03-c6b105344e1a">Amygdala</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8896184d-6c64-42ec-95f2-26b623bf8f72">
                                <link xl:href="http://snomed.info/id/4958002" xl:show="new">T-A3230</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57326c88-5012-45ae-9237-97eb04c8b11c">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0002708" xl:show="new">C0002708</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f290a18b-61a6-4faa-a733-8efbcb59cdf6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7dc87cd9-4478-4f0b-83e3-9b0b702d4659">
                                <link xl:href="http://snomed.info/id/119238007" xl:show="new">119238007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b851a023-5546-4d1c-9576-1e21989a1337">Brain Stem</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8b50f4aa-c3a5-470a-9baa-6ed52d2bb8f9">
                                <link xl:href="http://snomed.info/id/119238007" xl:show="new">T-D0558</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f805bb00-28f1-4521-b724-34f0c719b7f1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1268144" xl:show="new">C1268144</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1b1e8f5-b534-478b-9481-17fb6cc7eac9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8cc91fb3-7830-4ba1-a86a-53f10760b0a4">
                                <link xl:href="http://snomed.info/id/11000004" xl:show="new">11000004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4be273b1-fa8a-4a52-b184-d680a0a0ed0c">Caudate Nucleus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_113726fc-6bc8-4053-9f2f-7d88733546c4">
                                <link xl:href="http://snomed.info/id/11000004" xl:show="new">T-A3200</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c7cae0cb-871a-458f-9e5d-72d7ab9fefa4">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007461" xl:show="new">C0007461</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff72f873-9e52-434f-8037-4faa69ad56b7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3672bfe8-32bf-473b-96c7-8e9c86f26a38">
                                <link xl:href="http://snomed.info/id/25991003" xl:show="new">25991003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ec307cb7-fff3-405b-8ec9-3836e0e088ab">Cerebellar Cortex</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19d6ce2b-5733-4f56-9755-0090fbe8b30e">
                                <link xl:href="http://snomed.info/id/25991003" xl:show="new">T-A6040</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bdfbeb75-c78b-41bf-94bd-95201e37c041">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007759" xl:show="new">C0007759</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b1e3d9cc-f164-417b-99c9-9f4b1ae87755">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3937aad8-7296-42f0-93a5-b86d25e4b414">
                                <link xl:href="http://snomed.info/id/33060004" xl:show="new">33060004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cc7df3d5-05f2-4629-b3eb-b5709a48e215">Cerebellar White Matter</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8bf56a2-2ed8-48e1-bb21-a4049ff23561">
                                <link xl:href="http://snomed.info/id/33060004" xl:show="new">T-A6080</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7cd3709d-e2e8-41d3-99a2-2a918861c5e9">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152381" xl:show="new">C0152381</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                    <link xl:href="http://snomed.info/id/113305005" xl:show="new"><emphasis role="bold"><emphasis role="underline">113305005</emphasis></emphasis></link>
                                </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Cerebellum</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                    <link xl:href="http://snomed.info/id/113305005" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-A6000</emphasis></emphasis></link>
                                </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                    <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007765" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0007765</emphasis></emphasis></link>
                                </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21b898c6-ddb9-475b-b714-10489951b05a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8655b8ba-f71b-49d8-b8a1-b9e2cc2481a9">
                                <link xl:href="http://snomed.info/id/40146001" xl:show="new">40146001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b56f1c32-53a9-47f1-b8ad-df55ae107038">Cerebral Gray Matter</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f71d524-cece-45b6-8df9-4505730872eb">
                                <link xl:href="http://snomed.info/id/40146001" xl:show="new">T-A2020</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2b7cb7c7-f50a-47fb-9a94-daf578836e13">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007776" xl:show="new">C0007776</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47935571-825a-497e-84e6-2afee38cbf35">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b39064c-548c-497c-af17-02fa3f8ed283">
                                <link xl:href="http://snomed.info/id/68523003" xl:show="new">68523003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9849121f-4eae-4d55-b823-3f7a5a78d113">Cerebral White Matter</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11107683-cb78-4c7f-bcfd-2b3ee83e33bc">
                                <link xl:href="http://snomed.info/id/68523003" xl:show="new">T-A2030</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e46cef7a-e451-47df-ac4a-bb8748ccc442">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152295" xl:show="new">C0152295</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19cd0c70-c00a-4921-a9b1-7693e1408740">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_13a10324-c8f5-465f-a8de-2b82a9b37984">
                                <link xl:href="http://snomed.info/id/1101003" xl:show="new">1101003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_54aab7fd-0d81-4cab-9ca0-d6cc6114fed2">Cranial Cavity</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7bf04f6b-4732-4621-8b76-558aba5ae552">
                                <link xl:href="http://snomed.info/id/1101003" xl:show="new">T-D1400</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1cce42b5-be78-4038-9495-634a4ce10abc">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0230041" xl:show="new">C0230041</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a44ad48-239d-4c30-b70f-2d8aca081763">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ffa4c0d-9578-439d-b691-c9bddc19d8f0">
                                <link xl:href="http://snomed.info/id/33930006" xl:show="new">33930006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f99ad5a4-8548-4de8-963d-04f681742775">Cranial Subarachnoid Space</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6a034ffc-0521-4608-9ef9-e5e560460fad">
                                <link xl:href="http://snomed.info/id/33930006" xl:show="new">T-A1502</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_332991f0-7584-417e-9fb2-10bdeaca3b27">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0228145" xl:show="new">C0228145</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1370ca48-23da-4ca9-ba03-cdc4437d0821">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_511e5621-1b5c-4e27-8ea9-5a62186c40ca">
                                <link xl:href="http://snomed.info/id/74968005" xl:show="new">74968005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_94cb2957-84d6-451d-8ff9-ca7b6c8f7307">Cavum of septum pellucidum</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7c0b4899-7d8b-4ad6-b1b1-a41e958d311e">
                                <link xl:href="http://snomed.info/id/74968005" xl:show="new">T-A1630</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_919c3cda-1933-402b-8bb5-017cfe814e21">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0228158" xl:show="new">C0228158</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_066c4151-dfd3-453f-886e-a419a25f975e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8fc9a8e-5461-4360-b5c2-6794283b2052">
                                <link xl:href="http://snomed.info/id/35918002" xl:show="new">35918002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_76a6ee5f-2eab-4d36-8a18-1890bb267be8">Fourth Ventricle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f7f8890-7088-449a-bc01-50563ab32cfb">
                                <link xl:href="http://snomed.info/id/35918002" xl:show="new">T-A1820</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56d34367-6b16-4fc6-8823-14b61b53d310">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0149556" xl:show="new">C0149556</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3fc05675-3ae2-422f-b7d6-bdd5e4591271">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c08d230-9516-4eaf-8bac-173f82259477">
                                <link xl:href="http://snomed.info/id/14738005" xl:show="new">14738005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_621ebfde-3703-4790-a60a-8b85c84b13ac">Globus Pallidus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_55e7eb72-b821-4fbe-a5eb-0ee78de48b3f">
                                <link xl:href="http://snomed.info/id/14738005" xl:show="new">T-A3500</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fde072d6-3382-4ac6-8d5d-360009af3874">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0017651" xl:show="new">C0017651</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_61b8ba8d-3687-400d-9800-e8a114029e20">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7bfb6e86-a992-4552-9501-a00263e5e647">
                                <link xl:href="http://snomed.info/id/5366008" xl:show="new">5366008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b02b8741-85cc-4774-927c-0ba995afd10b">Hippocampus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6184ac4d-234f-4479-870c-5c06f19b5a72">
                                <link xl:href="http://snomed.info/id/5366008" xl:show="new">T-A2570</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8f065bae-e203-4ed2-bb1f-d9e7367506ed">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0019564" xl:show="new">C0019564</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_044bafd8-5cdf-4e8b-840c-63a74fbe130c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8edc92d7-934d-48a1-a29e-46c26f5f1d48">
                                <link xl:href="http://snomed.info/id/263972004" xl:show="new">263972004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_318c9829-842f-415a-9058-6c0eac317a59">Cerebellar Subarachnoid Space</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e85e89df-1086-46b8-9f8e-fbfc50947e84">
                                <link xl:href="http://snomed.info/id/263972004" xl:show="new">T-A1509</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6dd76299-ed7b-4e15-a5d5-edbaecb16374">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0446676" xl:show="new">C0446676</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_407019ce-e8a8-4bbd-a3ce-4abb84cfcec6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_07525d13-cc6d-41d0-9d35-cce3c2f28551">
                                <link xl:href="http://snomed.info/id/53118009" xl:show="new">53118009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_791240fa-c229-4425-b76d-8c20da6d0b76">Inferior Horn of Lateral Ventricle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb65bde4-389b-4622-b439-a03a556f0741">
                                <link xl:href="http://snomed.info/id/53118009" xl:show="new">T-A1720</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_30c968e6-a042-4c8e-8aac-e581b9038fc8">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152283" xl:show="new">C0152283</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2b7e4a97-cb37-4319-a5a5-f25e35d2f85d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd6b028b-5741-4695-a89e-24ec3298390f">
                                <link xl:href="http://snomed.info/id/66720007" xl:show="new">66720007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1991b9b7-940c-4650-934f-e219d592c1dd">Lateral Ventricle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e498709c-ccfe-4dcd-83b0-6460b762873f">
                                <link xl:href="http://snomed.info/id/66720007" xl:show="new">T-A1650</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_459ccc44-76ac-44d3-810b-69742632c936">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152279" xl:show="new">C0152279</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47b3d5d9-4e4b-4be8-a36f-7a9f3c38c44b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ebc18792-8279-4912-ab40-89328bc14ffa">
                                <link xl:href="http://snomed.info/id/427667007" xl:show="new">427667007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_27a88635-e10b-4fd5-aaec-65ad9d27b798">Nucleus Accumbens</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e231ec19-47e2-4f93-a018-b74b5381e21e">
                                <link xl:href="http://snomed.info/id/427667007" xl:show="new">T-A0149</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a23baf9d-5b58-4609-b062-94d7cae7328c">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0028633" xl:show="new">C0028633</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e52acfb7-d891-4cd3-a95f-41fc95c40c85">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f31bf2ba-d7b0-459f-9259-d492190af42f">
                                <link xl:href="http://snomed.info/id/128319008" xl:show="new">128319008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8deedc4e-8123-4b33-90a0-2535d7b65558">Intracranial structure</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0acfcbfa-756e-4a54-91c7-b1e58400806a">
                                <link xl:href="http://snomed.info/id/128319008" xl:show="new">T-A0190</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4fc5cdc3-b774-4f77-9856-5d92ce19e09d">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1267697" xl:show="new">C1267697</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f3c880a-06ed-4580-895f-32297b7b9e0b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e7da0c71-a13f-4ed8-9d4b-30fcdef0bb0b">
                                <link xl:href="http://snomed.info/id/89278009" xl:show="new">89278009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bdd1eacd-8ae5-4228-9724-3d91a97a3702">Putamen</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_001c7680-7bf5-468e-b468-25129243ce46">
                                <link xl:href="http://snomed.info/id/89278009" xl:show="new">T-A3400</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4c4fc6a-f53c-4705-99b2-375450d339d5">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0034169" xl:show="new">C0034169</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c630180-f0f6-4e47-b454-faef1736f2bf">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ce0a784-f250-421f-9fac-ecf18f64bc84">
                                <link xl:href="http://snomed.info/id/119406000" xl:show="new">119406000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4644df54-d34e-4bf4-964c-d8e1619d1aaf">Thalamus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2b8ecc7-d16d-453a-b2a7-15e3d151dd74">
                                <link xl:href="http://snomed.info/id/119406000" xl:show="new">T-D0593</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b67f756c-fcac-41f2-bcfc-4d68c95a2abb">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0458271" xl:show="new">C0458271</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0039a83-9934-45f3-a7ec-a06e51a1f5cc">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6c5c176e-01da-4c4a-84ed-e91e06033cce">
                                <link xl:href="http://snomed.info/id/49841001" xl:show="new">49841001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6cbdd839-f7fa-4f11-a115-e8b273c9aae8">Third ventricle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_460e19f5-f8f4-47c3-a369-be73047e0750">
                                <link xl:href="http://snomed.info/id/49841001" xl:show="new">T-A1740</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ba0150c-2aef-452a-8d08-6e67326af10c">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0149555" xl:show="new">C0149555</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_255e9cfc-41e8-41fd-a471-1572ce6e644c">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66ec881c-91a5-42e0-822d-ae13bcc57006">
                                <link linkend="DCM_110700" xrefstyle="select: nopage">110700</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a8da6501-de0f-4777-9b6b-f4d20b0ccff8">Ventral Diencephalon</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8665fef2-ca2d-4cd5-a263-a01d67599c98"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e71fabc-8bc2-4a0f-8987-ed0aa5ec70bd"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37be207c-106f-4435-852f-b18d29c33619">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c6d91fa6-024c-4aef-955d-d426a2c01822">
                                <link linkend="DCM_110701" xrefstyle="select: nopage">110701</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c137dd65-1895-4c6c-b8cb-46fb255bf454">White Matter T1 Hypointensity</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd2629bc-27ee-46fe-be19-40c08b5092fe"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_61046322-2284-4603-8dc1-d93d80dca20d"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e800ccf2-bb3a-403d-b03b-48574fb031fe">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80f340d0-46db-41bd-af9d-cff666d2048e">
                                <link linkend="DCM_110702" xrefstyle="select: nopage">110702</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_98da2f6e-b77c-41ae-b403-dd699dc2febd">White Matter T2 Hyperintensity</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6456a6ba-3b3f-47fa-bb93-800ef49ade31"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1eb817e1-72ec-43e2-bdf1-4d54e9c1c343"/>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <orderedlist numeration="arabic">
                    <listitem>
                        <para xml:id="para_f3927fab-3f9c-4244-8c97-ce7bae2f1b6e">
                            <link xl:href="http://snomed.info/id/88454005" xl:show="new">(1101003, SCT, "Cranial Cavity")</link> may be used to describe the volume of the entire intra-cranial space (intra-cranial volume or ICV) though the coded concept used is "structure of" rather than "entire" to be consistent with normal DICOM practice.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_1930387d-5602-4844-8a20-3fa24e7bdfd7">
                            <link xl:href="http://snomed.info/id/25991003" xl:show="new">(25991003, SCT, "Cerebellar Cortex")</link> is the gray matter of the cerebellum (as distinct from <link xl:href="http://snomed.info/id/33060004" xl:show="new">(33060004, SCT, "Cerebellar white matter")</link>).</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_557ae3cc-ad54-410a-892f-b3f4498c8fab">
                            <link xl:href="http://snomed.info/id/33930006" xl:show="new">(33930006, SCT, "Cranial Subarachnoid Space")</link> may be used to describe the volume of the exterior CSF (surrounding the brain, excluding the ventricles).</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_8f75c726-2b21-46f6-a9f0-1184cd970ef6">
                            <link xl:href="http://snomed.info/id/263972004" xl:show="new">(263972004, SCT, "Cerebellar Subarachnoid Space")</link> may be used to describe the volume of the inferior intracranial CSF space (infra-tentorial).</para>
                    </listitem>
                </orderedlist>
            </note>
        </section>
        
        <section label="CID 7153" status="3" xml:id="sect_CID_7153">
            <title>CNS Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_8f671764-6ce2-4002-9d43-6f7303e9711f">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7153.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7153.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7153.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.499.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_87c85f02-4286-476e-8e33-47a5b316ba2f">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_db355be4-8712-4668-a34e-345ce0e30752">
                            <emphasis role="bold"><emphasis role="strikethrough">20200309</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                            </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_9855fa3b-87e5-4eb6-81d3-606cfa41c164">
                            <emphasis role="bold">1.2.840.10008.6.1.499</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7153" rules="all" xml:id="table_CID_7153">
                <caption>CNS Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9a37db76-533e-41b1-acf8-c6ea34eeee3b">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_195bb38d-ddc9-4756-becf-ea26976a2b98">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37769f6f-da17-40cf-acf6-d338a2eb2de5">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b28dffc3-c774-400f-a235-0a93076edf2a">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7cc9750-81c7-4a23-b5fd-6fd95b3c55ec">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0afe2bd-09ac-42c6-9711-27d2b979fed3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_152cab37-4db5-4768-9fab-e0848b7ce88f">
                                <link xl:href="http://snomed.info/id/62818001" xl:show="new">62818001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1d620992-f946-4070-95a9-2985123846ae">Adenohypophysis</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1002f75-7193-498c-b103-2fb7ecf4ee31">
                                <link xl:href="http://snomed.info/id/62818001" xl:show="new">T-B1100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_560ed0c6-83bb-424c-b216-b3e01500305f">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0032008" xl:show="new">C0032008</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc58b97a-4069-4a44-a1c5-c35cde1fffed">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c6d2a5f-2542-40a2-8e4a-d4f9067ed1ef">
                                <link xl:href="http://snomed.info/id/4958002" xl:show="new">4958002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_89499293-c5a2-457a-b7bd-35e751486a52">Amygdala</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8441a901-715e-4b24-bba6-296ef4936c22">
                                <link xl:href="http://snomed.info/id/4958002" xl:show="new">T-A3230</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_975ac31c-38c3-4917-82d1-d6473ed937df">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0002708" xl:show="new">C0002708</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_52e2aea2-4b17-477f-a393-3390b8e8b08e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_991691e8-81e0-42fc-a0f7-6603c1eaa7f0">
                                <link xl:href="http://snomed.info/id/75042008" xl:show="new">75042008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_588bd33b-42b0-44c0-ab74-158c8dd56734">Arachnoid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b26f197e-2c4e-427e-bc3b-791fbb446d07">
                                <link xl:href="http://snomed.info/id/75042008" xl:show="new">T-A1220</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bdc91274-497c-4299-9b4f-fac3073ddaee">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0003707" xl:show="new">C0003707</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59971535-93d7-4475-b23b-072c4923e826">FMA</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3eb7d8e8-3b4e-4985-ab9b-b0cb38d90b13">
                                <link xl:href="http://purl.org/sig/ont/fma/fma276650" xl:show="new">276650</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_daf8b8b9-ddf6-4c81-9098-51ab0fab1886">Arcuate Fasciculus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c9d7378-749e-4fee-8107-997b28e88e0d"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3af7914-6ec7-407f-8195-08862c84e312">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2329633" xl:show="new">C2329633</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85696285-b064-4753-b811-6aab041a207a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6a4d32b-9b19-42b2-adc9-6eafeac4c9ab">
                                <link xl:href="http://snomed.info/id/12738006" xl:show="new">12738006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4e4eee9e-5439-4203-a080-f01b88fdcc9d">Brain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4dcdc678-ba35-43ac-a6c9-9aaf6a6c663e">
                                <link xl:href="http://snomed.info/id/12738006" xl:show="new">T-A0100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8d80f3d-b93f-4244-bbcc-aaea989bbad2">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0006104" xl:show="new">C0006104</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_358161d6-bce3-433b-a3aa-4cb998309557">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ec23579-47a8-4813-9111-01c5b4062f02">
                                <link xl:href="http://snomed.info/id/280371009" xl:show="new">280371009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_eb7b6c79-c093-4591-8aec-759e3cf23d40">Brain cerebrospinal fluid pathway</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f5ca0099-4be0-4813-aa98-4fdacb25ec1b">
                                <link xl:href="http://snomed.info/id/280371009" xl:show="new">T-A0109</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_41019a4f-58a4-4758-92bb-1a86a436b27e">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0459387" xl:show="new">C0459387</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e89cb4f-5033-472f-b2d3-900fec12396f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2b924113-998f-485a-ab76-8938606da341">
                                <link xl:href="http://snomed.info/id/119238007" xl:show="new">119238007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ac6dc203-0cc0-4c23-8355-e1c2f2502044">Brain stem</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_edf53424-6618-444d-b654-cb20e9cb0c57">
                                <link xl:href="http://snomed.info/id/119238007" xl:show="new">T-D0558</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5fba1687-6201-42c3-a276-7b70fc9ce83d">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1268144" xl:show="new">C1268144</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6e7ef9b-4bb6-44bc-b3b8-55ebe24cd7ce">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_73cec448-91c2-4f12-96f7-bab72d265634">
                                <link xl:href="http://snomed.info/id/35764002" xl:show="new">35764002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4571138a-79c1-401c-ab33-dba7b8e0aba7">Brain ventricle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8ee2b55-6197-43f4-b3a2-fc67438a7bf1">
                                <link xl:href="http://snomed.info/id/35764002" xl:show="new">T-A1600</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5363fdfa-eac9-47da-8421-3967c6fbbdd8">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007799" xl:show="new">C0007799</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0975a28d-5171-42b0-8048-ff60d4e083b2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b1ce0f7-1b74-4683-b8a7-5e6b940bace1">
                                <link xl:href="http://snomed.info/id/11000004" xl:show="new">11000004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c41d5567-8232-4815-9775-eace3921084a">Caudate nucleus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9867521-ec9c-4def-8f35-47905127d665">
                                <link xl:href="http://snomed.info/id/11000004" xl:show="new">T-A3200</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7359910e-c98d-4121-b028-e82c2e94ff81">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007461" xl:show="new">C0007461</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b39e910f-8cc1-4531-a0ef-5dbe8d413523">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_302cbd38-0f35-49bd-858e-eed33684d993">
                                <link xl:href="http://snomed.info/id/21483005" xl:show="new">21483005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0fa86e43-bd19-42b9-b422-f498e8d1cfae">Central nervous system</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e271be6c-ec4c-4308-b1b8-a21d5b84de88">
                                <link xl:href="http://snomed.info/id/21483005" xl:show="new">T-A0090</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_45f4717c-ad0c-40ad-bb9b-2bc6295cafe1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0927232" xl:show="new">C0927232</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a65069f8-3960-43c0-972a-51e33e644a1b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87922862-0592-4ef3-8b12-823fd654af21">
                                <link xl:href="http://snomed.info/id/33060004" xl:show="new">33060004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_23ff8a1f-8949-49b3-adc8-d7486381ca78">Cerebellar white matter</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_656ca2d7-1d7a-40a8-b688-de6b1e121233">
                                <link xl:href="http://snomed.info/id/33060004" xl:show="new">T-A6080</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90954ed2-1104-4b29-8f08-92bf40e2d4f1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152381" xl:show="new">C0152381</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/113305005" xl:show="new"><emphasis role="bold"><emphasis role="underline">113305005</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Cerebellum</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/113305005" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-A6000</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007765" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0007765</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1334fb87-162b-4b33-8438-6576805b35c2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_61a2246a-c15e-4180-a5b5-bd37c0a825d8">
                                <link xl:href="http://snomed.info/id/80447000" xl:show="new">80447000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6bed1eed-6335-4b41-860c-b3f7754de6ac">Cerebral aqueduct</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_18ee5465-3f39-49db-93b1-3bd5149c369e">
                                <link xl:href="http://snomed.info/id/80447000" xl:show="new">T-A1800</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0b02047-f036-4926-9137-bbea0b2f2506">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007769" xl:show="new">C0007769</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5520570-d07d-47e1-949f-7b813a69593d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0b34f311-5fef-4155-aa6c-f76195f1b0b0">
                                <link xl:href="http://snomed.info/id/40146001" xl:show="new">40146001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bae7f7a1-c63e-47ca-a901-78b21601893f">Cerebral cortex</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_094427d0-1c78-40e0-80bb-69392278b460">
                                <link xl:href="http://snomed.info/id/40146001" xl:show="new">T-A2020</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cdc73182-eebb-42ac-a269-f97300e75431">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007776" xl:show="new">C0007776</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_efc0fe43-e1dc-4e17-970e-b93fd66d26d2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d3de464-1855-4a1b-884e-2174af11c820">
                                <link xl:href="http://snomed.info/id/87463005" xl:show="new">87463005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e95e852f-c133-40cc-808a-8aa1dfe3e240">Cerebral fornix</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70b0ab59-adac-4ce4-b232-74862ab59fb0">
                                <link xl:href="http://snomed.info/id/87463005" xl:show="new">T-A2970</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9905b9d-ae2a-40f8-a5f9-453d60adf744">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152334" xl:show="new">C0152334</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0b4c77c9-76ee-447d-9466-2b33b157ae51">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47da7154-dcd7-41b5-9a00-49f99456e001">
                                <link xl:href="http://snomed.info/id/40146001" xl:show="new">40146001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2e268fd1-48fa-471e-85f4-96b9c4ef8bd3">Cerebral Gray Matter</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_296406a7-ebc0-4df7-8a35-547a6f5d38f0">
                                <link xl:href="http://snomed.info/id/40146001" xl:show="new">T-A2020</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09612b8b-a60d-43db-b969-8d2ece980ba8">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007776" xl:show="new">C0007776</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_780f4e53-1c32-40cb-b839-acb2fbab224c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d087ca03-60e9-4890-a734-d49698391fde">
                                <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=372073000" xl:show="new">372073000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_117d0eb6-ca5c-427e-a18c-dd60d3b6b863">Cerebral hemisphere</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ec00fcc-c574-496b-8cf6-d240f5e56580">
                                <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=372073000" xl:show="new">T-A010F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c5c59e47-2045-4d8c-9d71-f38201f995b8"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bcc5aa10-5e87-4b0b-a9b3-b13c740664e2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_176f826b-7adb-4d87-8493-c6fcdb68c9ce">
                                <link xl:href="http://snomed.info/id/68523003" xl:show="new">68523003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d7700fda-543f-4d10-b84a-38e007340046">Cerebral White Matter</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ec677aa-01aa-4a1c-a246-62f851696853">
                                <link xl:href="http://snomed.info/id/68523003" xl:show="new">T-A2030</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e37ab0f7-f195-4be2-8126-42d62bdbd55c">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152295" xl:show="new">C0152295</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f9d23e9b-d962-4012-a07c-3c85b403a77a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f85bfa4a-ddce-42bf-ac9e-eac85bdc7db7">
                                <link xl:href="http://snomed.info/id/65216001" xl:show="new">65216001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f8b4d11d-3645-4a7b-9063-ad29f0df3fdf">Cerebrospinal Fluid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_01332d27-ea3b-478f-be3c-a88c112d034d">
                                <link xl:href="http://snomed.info/id/65216001" xl:show="new">T-A1000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df0190d1-3582-4322-ac20-d065101cc917">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007806" xl:show="new">C0007806</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c34093b0-7b52-47f5-8bef-843173c05d60">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7dfe7fda-9031-4827-aefc-303db2039393">
                                <link xl:href="http://snomed.info/id/37035000" xl:show="new">37035000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0441fc8e-b943-4370-8246-648cfa390fa5">Cingulum</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7c77fb18-fe43-4be1-b934-8995ea02bc5c">
                                <link xl:href="http://snomed.info/id/37035000" xl:show="new">T-A2840</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9d76bd8-de86-4e73-99a3-9e7cac410cbc">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0228272" xl:show="new">C0228272</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_15a3d0a9-a075-46ff-9523-6171ced58bdc">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c778f139-9d86-4dd5-960c-d5a22bbd7ddc">
                                <link xl:href="http://snomed.info/id/88442005" xl:show="new">88442005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d0e45b60-fa17-44f8-9675-2acf48e53565">Corpus callosum</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_263cbbba-2e76-4321-a3a0-d14300d8fac0">
                                <link xl:href="http://snomed.info/id/88442005" xl:show="new">T-A2700</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9be846d9-6ce6-472c-a974-b12bbf194891">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0010090" xl:show="new">C0010090</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db2c418f-9fa2-4dd2-91ca-d7d763114c9b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62dab932-74f1-4744-90b6-7cfbb732aca1">
                                <link xl:href="http://snomed.info/id/31428008" xl:show="new">31428008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9f16423b-eb3f-49e8-bb9f-0270e3d4e62f">Corpus striatum</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7df777cd-0799-498b-b0f2-c52c00535329">
                                <link xl:href="http://snomed.info/id/31428008" xl:show="new">T-A3100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90847d69-fe8f-4e32-8395-5d9a32ed3d98">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0010097" xl:show="new">C0010097</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_488eaeaf-77e7-4d2f-a938-9b2b130cc595">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a5343464-dca2-4671-91d8-5c4be76afb9d">
                                <link xl:href="http://snomed.info/id/87563008" xl:show="new">87563008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0b06c4ee-a91f-4d9c-9b77-d5e18357f22b">Diencephalon</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_571fbd4e-5f27-452f-ba87-919f2e8337b9">
                                <link xl:href="http://snomed.info/id/87563008" xl:show="new">T-A0102</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1cd27156-8a59-4d94-9763-0871366e0b71">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0012144" xl:show="new">C0012144</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4dc29352-864e-4cfa-ba8c-151e0a70f51b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8727deeb-1b5d-4251-b489-2801910c7295">
                                <link xl:href="http://snomed.info/id/18545000" xl:show="new">18545000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_de391d7b-6f80-4d3e-b545-df0df1a1d55a">Dura mater</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f457648d-0859-4b72-b5ee-568af92e92a6">
                                <link xl:href="http://snomed.info/id/18545000" xl:show="new">T-A1120</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a0e9c960-aeff-4967-9c20-4a97d7fc6e86">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0013313" xl:show="new">C0013313</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bf3498be-e164-4d69-b26b-1656d187ad35">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60e083bc-e46f-4237-af21-f86dbbd0b364">
                                <link xl:href="http://snomed.info/id/3937002" xl:show="new">3937002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bd73af98-3c16-4eb0-ab6e-08a2f1ad8d0b">Entorhinal Cortex</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9beda05f-4e8a-4d53-97fa-383e0d30ae8c">
                                <link xl:href="http://snomed.info/id/3937002" xl:show="new">T-A2594</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e9d327e-01a6-47ae-b4ba-4a69ca1f8d86">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0175196" xl:show="new">C0175196</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_94110030-6afd-4b59-97ac-6a146d48372c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dd1acfe0-427e-413d-a1c1-25203dcadfdb">
                                <link xl:href="http://snomed.info/id/35918002" xl:show="new">35918002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_518ec159-0398-4e18-bfa2-ca587a87050e">Fourth ventricle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d9b5ece-675c-471b-b9da-2b916813a54e">
                                <link xl:href="http://snomed.info/id/35918002" xl:show="new">T-A1820</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3c0c38a-91ea-44e5-b541-dc59e555cfb6">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0149556" xl:show="new">C0149556</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8e502d7-44ad-48c0-b49b-7922db6558b0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b5554dbd-5304-4f86-bf00-4d3a7a9f9f39">
                                <link xl:href="http://snomed.info/id/83251001" xl:show="new">83251001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b967b289-f58d-4008-8bb9-cb2d0343be6f">Frontal lobe</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e5185e9-2994-473d-bf6d-4f324fe159c1">
                                <link xl:href="http://snomed.info/id/83251001" xl:show="new">T-A2200</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ca7a09ec-773e-4cbd-920c-173aecabc9a5">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0016733" xl:show="new">C0016733</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_748b5d8d-0cc4-4d2f-aa05-42c1c3a71c21">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_97ae4861-b9a6-4eeb-b8f9-1148e21224f4">
                                <link xl:href="http://snomed.info/id/14738005" xl:show="new">14738005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4cf27a8f-1041-446f-83cf-5e80ce260afc">Globus pallidus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_17aab040-ad18-43e7-918c-c9c8cd99cc59">
                                <link xl:href="http://snomed.info/id/14738005" xl:show="new">T-A3500</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d22fd69-3d49-46a0-a378-68b7deb1c89e">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0017651" xl:show="new">C0017651</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b96230a-b29a-4bb1-b464-f976f7cddc60">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1432c1f8-658c-47e4-aa1c-9d9d5ab8be65">
                                <link xl:href="http://snomed.info/id/389081007" xl:show="new">389081007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d9eac82e-1f1a-48da-b192-9b4077447b95">Gray Matter</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0eaefc2c-3aa3-4ddf-a09a-8362f2f4da7c">
                                <link xl:href="http://snomed.info/id/389081007" xl:show="new">T-A0096</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b59256be-5581-47db-82aa-be7111ccf79e">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1300312" xl:show="new">C1300312</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c90ef71-c1bd-465c-8086-785e0ce3799f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_defd0b7b-2ff9-4fba-815c-dee8d49ad346">
                                <link xl:href="http://snomed.info/id/5366008" xl:show="new">5366008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_966a8422-0cd4-4278-aed9-9caa7f9a357e">Hippocampus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3eb742a4-c252-4c1a-9894-23f555dfadce">
                                <link xl:href="http://snomed.info/id/5366008" xl:show="new">T-A2570</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aec7a866-ed3e-49c8-8865-a89193132b19">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0019564" xl:show="new">C0019564</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_17f8a109-d992-4670-a090-10341d728786">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f9e32765-221d-4fb7-aec6-f1b42b6afdc0">
                                <link xl:href="http://snomed.info/id/67701001" xl:show="new">67701001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fbadc22c-86c0-449f-b1c2-cd956c1e2027">Inferior cerebellar peduncle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5988ba9e-0a74-43ad-8a1f-b024a8de391d">
                                <link xl:href="http://snomed.info/id/67701001" xl:show="new">T-A6640</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66c0ed6d-81c4-4fbe-b872-37a2c7ea4c5f">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152393" xl:show="new">C0152393</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d09c040d-56c2-46c4-8b85-b655c00f4ccf">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1b0c5614-4166-40ae-8d5d-51aefdbe8e5c">
                                <link xl:href="http://snomed.info/id/55233005" xl:show="new">55233005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5608eb11-b89f-4fbd-ae23-f66f4a1fb0d0">Inferior longitudinal fasciculus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_29babfda-b198-48d1-9ccb-faec26879969">
                                <link xl:href="http://snomed.info/id/55233005" xl:show="new">T-A2850</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_019e8492-fd0a-4b78-90fc-7aff43bacfbd">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0228273" xl:show="new">C0228273</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9dc4fdee-e355-4536-b79f-42854828b650">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_621ec33b-8e6d-4b91-be41-a7c092eb31f6">
                                <link xl:href="http://snomed.info/id/36169008" xl:show="new">36169008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3d78f883-5efc-4371-98a6-4ee84f766e17">Insula</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8e65bb95-c711-4fe6-a790-5c135b98949b">
                                <link xl:href="http://snomed.info/id/36169008" xl:show="new">T-A2610</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c39e74d6-e31f-4066-950b-e29275117935">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0021640" xl:show="new">C0021640</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_05633f46-f98a-4582-b597-540fceafbe0e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e09e0437-6a20-4818-bba5-ea77ec464d0f">
                                <link xl:href="http://snomed.info/id/461002" xl:show="new">461002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b1050b3b-7214-4807-a88b-c0a9e1e08f93">Lateral corticospinal tract</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc13df6f-001a-470f-9a4c-d62b0465fd65">
                                <link xl:href="http://snomed.info/id/461002" xl:show="new">T-A7093</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_287225e3-b76b-4d01-a1ea-86bd52885597">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152402" xl:show="new">C0152402</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a69e534-536b-4003-aab5-49a00efb7d9c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9a199704-523b-4e1c-959d-e8f2f85b8fb8">
                                <link xl:href="http://snomed.info/id/66720007" xl:show="new">66720007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7c8d65dd-797f-4098-9fa5-40bbea932e61">Lateral ventricle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_163100cd-a7b2-4d7a-b1a4-207dbc619634">
                                <link xl:href="http://snomed.info/id/66720007" xl:show="new">T-A1650</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f8a911b-efc8-4dcb-ae73-2c457f648395">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152279" xl:show="new">C0152279</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4e291dd-75f2-45ed-883b-fa2c78ba2320">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b375a7c9-652a-4f00-915a-c76ddbee1866">
                                <link xl:href="http://snomed.info/id/279215006" xl:show="new">279215006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5b45fc3c-ed73-4883-a9f0-e15a15fcc787">Limbic lobe</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3087defd-bd1b-42f7-9926-fe88da79bd75">
                                <link xl:href="http://snomed.info/id/279215006" xl:show="new">T-A0036</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d935442-0dad-4a80-bc49-311c80d5dd42">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0458337" xl:show="new">C0458337</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5de0e89-0652-4919-8712-896e17226f96">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eda39d0c-cf1c-4b28-8c7a-c34ce0458c70">
                                <link xl:href="http://snomed.info/id/30114003" xl:show="new">30114003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_63cdef00-6a10-440f-bddd-0c3932c9553d">Medial Lemniscus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19e51243-b0ad-4d5b-9032-3ffe67e86170">
                                <link xl:href="http://snomed.info/id/30114003" xl:show="new">T-A5271</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5829f6e5-9beb-440b-970d-ff7e6336ea58">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0228420" xl:show="new">C0228420</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0df0f3b6-1364-4a9c-8405-187dddcd98f4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91df09c9-ff7f-47d7-bc09-707cc5d4d49a">
                                <link xl:href="http://snomed.info/id/1231004" xl:show="new">1231004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_91c7b5ce-37cf-4ebc-a308-98399ed21024">Meninges</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98059078-4dd1-4c71-861b-a9af3c15afd5">
                                <link xl:href="http://snomed.info/id/1231004" xl:show="new">T-A1110</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_52ef490f-7d09-44d2-9902-aea5489d58a0">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0025285" xl:show="new">C0025285</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf1c4473-5d8f-4c68-99e4-abec7415a003">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd847526-43a6-4df4-b944-e60fa77640ea">
                                <link xl:href="http://snomed.info/id/61962009" xl:show="new">61962009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cc0bb02d-633a-4dc0-8433-58f48260717a">Midbrain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1690eec0-2c9b-4154-b815-72dcb8fa71b4">
                                <link xl:href="http://snomed.info/id/61962009" xl:show="new">T-A5100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_beaffed5-ee0b-4b34-841d-eba6956f1ba2">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0025462" xl:show="new">C0025462</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3046092f-63a4-42be-8d21-c53ddf644d7e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6636336b-4231-45e6-916c-03b3a248ead0">
                                <link xl:href="http://snomed.info/id/33723005" xl:show="new">33723005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d13b0b94-fa03-49af-a22e-08f47a8b015a">Middle cerebellar peduncle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9387a915-c7b9-4a8c-a84c-69a559da39b9">
                                <link xl:href="http://snomed.info/id/33723005" xl:show="new">T-A6630</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8ff28baf-8ee1-4a28-8df2-0f68ff079c94">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152392" xl:show="new">C0152392</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3b35465-4741-4e2c-8bcb-f8c88cb4bf3b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5bf58161-ac64-44a8-8798-5b6e4737033d">
                                <link xl:href="http://snomed.info/id/427667007" xl:show="new">427667007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_46b141a8-cd35-423a-9431-ccf30897c972">Nucleus accumbens</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_451543f0-f7b3-4855-bbbb-517f7cd99e4e">
                                <link xl:href="http://snomed.info/id/427667007" xl:show="new">T-A0149</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fbc50cc8-83be-4bc8-9639-fc45babe7535">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0028633" xl:show="new">C0028633</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8858fe3f-257a-482c-a209-309e437e93f3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_577a9d07-64f9-4b50-8c3d-2c851055a2e9">
                                <link xl:href="http://snomed.info/id/37512009" xl:show="new">37512009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5f28aa9f-8235-4001-8091-7a3906e75eea">Neurohypophysis</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b56ff034-5e23-43c7-8400-063d2b6514f6">
                                <link xl:href="http://snomed.info/id/37512009" xl:show="new">T-B1200</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_debe090c-8f1b-45f0-8149-35ff96491147">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0032009" xl:show="new">C0032009</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_73d12253-8680-4751-ac0a-90309ca9eb6c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87c081e5-f187-414b-8c18-3b055230ca92">
                                <link xl:href="http://snomed.info/id/31065004" xl:show="new">31065004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8710d98c-fbda-44c6-98ed-f8924870070e">Occipital lobe</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f89aed83-e16f-45cb-8ffc-928a5bcba3c4">
                                <link xl:href="http://snomed.info/id/31065004" xl:show="new">T-A2400</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a6073e1-7d75-413e-a2af-a0d5f6977ded">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0028785" xl:show="new">C0028785</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3998ddd-e1ea-4d78-934a-bba680392b19">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e247470f-a634-4beb-a912-84ae70006ceb">
                                <link xl:href="http://snomed.info/id/244453006" xl:show="new">244453006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a99bf762-849d-4704-b763-4fdc74667620">Optic chiasm</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8f6b5843-2ec1-4f5b-9839-6f5ac2b23479">
                                <link xl:href="http://snomed.info/id/244453006" xl:show="new">T-A800B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e8e68d7-4817-4376-a966-bc2593ac36e9">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0029126" xl:show="new">C0029126</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_28a7595f-b222-4c86-b93a-3043bea48010">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e598e438-f650-4e6b-8a76-4829def56dc0">
                                <link xl:href="http://snomed.info/id/70105001" xl:show="new">70105001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2dd6e698-a47c-4cb6-ac2c-a249f6ddc5b7">Optic radiation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_51fc2fac-e11e-45d5-8f73-bf33bb21088b">
                                <link xl:href="http://snomed.info/id/70105001" xl:show="new">T-A2880</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_efde1d4d-5666-478d-91dc-c4c91eed7c12">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0228277" xl:show="new">C0228277</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7fb449ac-217a-4ade-92ad-8806a863dbf9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b00e3046-d8e8-4480-98a5-4408f2992366">
                                <link xl:href="http://snomed.info/id/53238003" xl:show="new">53238003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dea7247e-cef2-4330-9642-602cdcc322cf">Optic tract</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aec83a9c-8f06-4361-86a8-73bcfd4ff003">
                                <link xl:href="http://snomed.info/id/53238003" xl:show="new">T-A8060</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fd786591-4eef-4057-a11f-2d9d182fa819">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152405" xl:show="new">C0152405</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47ee5a0e-344f-4f65-9d2b-3913ec25e466">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f41181ae-b92e-4652-ab33-1c627334410a">
                                <link xl:href="http://snomed.info/id/16630005" xl:show="new">16630005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aa1035f3-477f-4f8b-8d87-e8fa6d02eea2">Parietal lobe</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_49e7db6e-11f9-489e-801e-b30371906e5f">
                                <link xl:href="http://snomed.info/id/16630005" xl:show="new">T-A2300</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_635034df-56c4-454f-9acb-2c260bc9e106">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0030560" xl:show="new">C0030560</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_001a59b3-b577-4906-9ee9-4a6e12ffbabb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2999dc10-3757-45ac-bac9-3411a15a9e8d">
                                <link xl:href="http://snomed.info/id/23180006" xl:show="new">23180006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_35de55e8-15cf-4875-9566-b82a66f5465a">Pia mater</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f01b0853-3805-495b-a90f-cda304744a39">
                                <link xl:href="http://snomed.info/id/23180006" xl:show="new">T-A1280</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c2e0f80-883b-4a3e-a793-4e66700dac20">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0031869" xl:show="new">C0031869</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e831cbad-b886-4b9a-8e6d-bf174f842696">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_723bdb0d-57bf-4cfc-85fc-cab7cc28a43b">
                                <link xl:href="http://snomed.info/id/45793000" xl:show="new">45793000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c3be2def-47c9-409c-845e-d095db78ce01">Pineal Gland</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bcfac061-d144-4204-b293-dc5cfffccd5d">
                                <link xl:href="http://snomed.info/id/45793000" xl:show="new">T-B2000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a4f2be3c-6c63-4ce8-b386-3094089399b4">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0031939" xl:show="new">C0031939</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_547d216e-7e71-467c-ac17-28761d3d5b3a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d89bc837-8344-4046-9e4b-23b7d3dbb6f9">
                                <link xl:href="http://snomed.info/id/56329008" xl:show="new">56329008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e58889ab-6f7c-49d7-bcc8-c1f36a34813e">Pituitary</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_73091c3e-6ec5-4e14-b6d9-c09d8295e543">
                                <link xl:href="http://snomed.info/id/56329008" xl:show="new">T-B1000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f4090781-5c7e-4684-8de7-7ab615d8a0de">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0032005" xl:show="new">C0032005</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3ff7b7e6-9ca8-42dc-8a15-b4b3160dd459">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ae22893-64db-49ab-8239-135d15518ca6">
                                <link xl:href="http://snomed.info/id/279336005" xl:show="new">279336005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_80514b92-bbbb-473e-9510-337fe77d9d2d">Posterior cerebral commissure</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_079dc7b7-528f-4f92-a7e3-b3a313d04618">
                                <link xl:href="http://snomed.info/id/279336005" xl:show="new">T-A4904</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4195caf7-31ad-48fa-af3f-1225ea7986f2">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152327" xl:show="new">C0152327</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_086ae816-65d3-40f1-80c4-94c9ac489025">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6264e2a1-8fa2-47ec-a2fe-549606316955">
                                <link xl:href="http://snomed.info/id/89278009" xl:show="new">89278009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9bd2a9d8-75f6-49b3-a686-50ea256d1493">Putamen</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3228837f-79a4-4986-af18-b1bab7abbbe6">
                                <link xl:href="http://snomed.info/id/89278009" xl:show="new">T-A3400</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_52eadfcd-215a-46af-b99b-75de258ca43d">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0034169" xl:show="new">C0034169</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8b808edb-a597-4fbe-9a56-3ebbdaab0996">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0af2451-aa4e-48be-8a57-b92e35920157">
                                <link xl:href="http://snomed.info/id/280401006" xl:show="new">280401006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a8716c89-6bf3-4f3b-805a-82526ad69df5">Spinal cerebrospinal fluid pathway</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e9974a6-5144-40e2-9c0d-6a189fe67519">
                                <link xl:href="http://snomed.info/id/280401006" xl:show="new">T-D0721</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1411781-fc99-4c3b-a75c-40988adc8789">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0459413" xl:show="new">C0459413</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8e4511e2-32e0-45a8-8e5e-948510837bf7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5891072d-9e8b-425b-a3e7-5e553bcb7863">
                                <link xl:href="http://snomed.info/id/2748008" xl:show="new">2748008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_44d1bc6b-d3b3-4e79-b1dd-34a5b5b09a5e">Spinal cord</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91061758-4957-407c-8612-bd8ea4aae5b9">
                                <link xl:href="http://snomed.info/id/2748008" xl:show="new">T-A7010</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a336a0c2-003d-409f-8505-380d58c4eb93">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0037925" xl:show="new">C0037925</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a42fa5f1-e1e7-4b8a-87e1-2ef3cc1d1f13">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e7853de-8a05-45c7-96ed-c33ca4e0b3cf">
                                <link xl:href="http://snomed.info/id/12958003" xl:show="new">12958003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_205cad7e-7beb-42e6-9ab3-e1e751bb018d">Spinal cord gray matter</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b0b3ae2e-5c60-4553-8368-116ce49e3507">
                                <link xl:href="http://snomed.info/id/12958003" xl:show="new">T-A7020</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_55d5c5eb-84a6-4174-8c82-155287ed017c">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0475853" xl:show="new">C0475853</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_049df81b-0ea1-496c-91c0-295517cb9244">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0e31269f-fcd0-41af-ba3c-46ae6f6f1811">
                                <link xl:href="http://snomed.info/id/27088001" xl:show="new">27088001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_756043de-db25-438c-af57-ca35824808a8">Spinal cord white matter</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7262897-27b3-41c3-a178-10326b75743d">
                                <link xl:href="http://snomed.info/id/27088001" xl:show="new">T-A7070</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b8dcfb2-9cfd-4007-b5c5-5feb1528b9a0">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0458457" xl:show="new">C0458457</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86034a12-047d-40ff-89a6-42194fe4c019">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7186238a-b498-4ce0-ace5-8e68ef509fd6">
                                <link xl:href="http://snomed.info/id/35951006" xl:show="new">35951006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b5c162e9-b852-4a84-9f15-8e9bb531d5ad">Subarachnoid space</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d8fecec3-16ba-48b0-8e5f-efb02b11e61a">
                                <link xl:href="http://snomed.info/id/35951006" xl:show="new">T-A1500</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f18bb0c-85e9-4385-94a7-b498a4ddc092">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0038527" xl:show="new">C0038527</link>
                            </para>
                        </td>
                    </tr>
                        <tr>
                            <td align="center" colspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">FMA</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1">
                                <para>
                                    <link xl:href="http://purl.org/sig/ont/fma/fma223151" xl:show="new"><emphasis role="bold"><emphasis role="underline">223151</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="left" colspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Subcortical gray matter</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1">
                                <para/>
                            </td>
                            <td align="center" colspan="1">
                                <para>
                                    <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0038590" xl:show="new"><emphasis role="bold"><emphasis role="underline">C2333161</emphasis></emphasis></link>
                                </para>
                            </td>
                        </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a0537685-64d7-4141-acdb-480625e8abfd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d9d53bb-ccfe-42ee-abf4-a7993db223cb">
                                <link xl:href="http://snomed.info/id/70007007" xl:show="new">70007007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a4cc6d01-c249-4073-8c8e-64f911970883">Substantia nigra</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_be99f546-2e72-4ad3-9559-ff355eee7734">
                                <link xl:href="http://snomed.info/id/70007007" xl:show="new">T-A5160</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62d9beb0-2a82-48c4-b1e9-3b385098b028">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0038590" xl:show="new">C0038590</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db513ec8-040a-446a-9838-58ea345d697d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_25ddbf93-1a61-4e34-bda0-e2fa40ab00a2">
                                <link xl:href="http://snomed.info/id/11089000" xl:show="new">11089000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e9428377-a18b-4f26-85e0-39a6fb01a1ee">Superior cerebellar peduncle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de8d05fe-1d68-4283-a6cc-05dc46438335">
                                <link xl:href="http://snomed.info/id/11089000" xl:show="new">T-A6620</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a5806add-4931-45a2-adad-de1f56766f9c">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0152391" xl:show="new">C0152391</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4bec46af-5fe1-4fc9-8a79-db8cce571cd2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9efe375-1534-472c-8cb4-ef3271f8ddbb">
                                <link xl:href="http://snomed.info/id/89202009" xl:show="new">89202009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7f05674a-dd83-42a0-93e2-039a03812669">Superior longitudinal fasciculus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0925079d-c048-48f2-9cde-8b6701c72402">
                                <link xl:href="http://snomed.info/id/89202009" xl:show="new">T-A2820</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cbe3fab-0034-43a2-b0c0-928078708f42">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0228270" xl:show="new">C0228270</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc3cba9e-c7e2-4d69-a465-51f29d720b35">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac878dca-47c5-49a6-9eaf-fe6859a2a8db">
                                <link xl:href="http://snomed.info/id/11628009" xl:show="new">11628009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_23a3ca61-6a9f-4a11-b0f8-c76a0e4c59a9">Telencephalon</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fdb5ae86-0d54-4c66-954f-d0b06e28f638">
                                <link xl:href="http://snomed.info/id/11628009" xl:show="new">T-A0103</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_79824782-bb8a-4221-a48d-d10d052f179d">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0039452" xl:show="new">C0039452</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f926fbe1-e0a5-49e7-ac29-b706f6b0c652">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f35bf267-52b6-4227-bfc3-963dcc448aa2">
                                <link xl:href="http://snomed.info/id/78277001" xl:show="new">78277001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b7827cc9-f663-421e-a504-5e453554076b">Temporal lobe</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ab77d1f-8765-4faa-b8f1-9d280bb4a45f">
                                <link xl:href="http://snomed.info/id/78277001" xl:show="new">T-A2500</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e87f4fd-c589-4e6a-8468-f5f628e2a913">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0039485" xl:show="new">C0039485</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66342b04-37f3-4865-bbcc-50f75ef8a864">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b9875bba-6fe2-4507-872c-83bdcce6abfb">
                                <link xl:href="http://snomed.info/id/42695009" xl:show="new">42695009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4461d67b-b1cc-4477-b1a9-43bf2eafe40c">Thalamus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ad9157a-c5cf-47b8-b931-47b41afc0697">
                                <link xl:href="http://snomed.info/id/42695009" xl:show="new">T-A4000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_01afe517-487a-4214-b74a-75f9af535c5b">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0039729" xl:show="new">C0039729</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a22213e2-d684-4ab0-82c5-4cba65f9174e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1eeb1f75-6a42-4d74-9ba6-0469328de8bb">
                                <link xl:href="http://snomed.info/id/49841001" xl:show="new">49841001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c173d335-fc21-4107-9aa1-f17c363417a4">Third ventricle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c186011-3c41-4f78-8b77-25cc8d902681">
                                <link xl:href="http://snomed.info/id/49841001" xl:show="new">T-A1740</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0b510225-d092-4414-9d54-fa9370e74f2f">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0149555" xl:show="new">C0149555</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_464d3581-573d-4b9b-8272-116de9bef3b6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec94daa2-6fd7-410b-aefd-86914928c89c">
                                <link xl:href="http://snomed.info/id/26230003" xl:show="new">26230003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6c0d3100-866d-4800-9821-556d88c964fb">Uncinate fasciculus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_afc783c2-0c3e-41be-a95e-5a57b4af411e">
                                <link xl:href="http://snomed.info/id/26230003" xl:show="new">T-A2830</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9c687a0-848d-461c-8db6-7da42a0a38cd">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0228271" xl:show="new">C0228271</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec85b965-314b-4857-bfd8-3703e4481bf3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b50e1288-3875-4c14-b600-2d99594a54f8">
                                <link xl:href="http://snomed.info/id/389080008" xl:show="new">389080008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_801e4d4d-6a72-4fe3-9b73-0c242d9c665d">White Matter</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f424b85-4343-44eb-9e22-e719564175e3">
                                <link xl:href="http://snomed.info/id/389080008" xl:show="new">T-A0095</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09668f75-4545-4050-ac7a-40b8ef273287">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1300311" xl:show="new">C1300311</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 7159" status="3" xml:id="sect_CID_7159">
            <title>Lesion Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_091d9c60-0554-4643-824b-efbd4b9a9994">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7159.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7159.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7159.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.505.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_bb393902-4078-44bd-9ae0-4875b2517a86">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_504d4909-831f-40e7-a7c8-ae2d1693887d">
                            <emphasis role="bold">20210328</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_9e2a9b52-125c-4848-a39e-2553eefba12e">
                            <emphasis role="bold">1.2.840.10008.6.1.505</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7159" rules="all" xml:id="table_CID_7159">
                <caption>Lesion Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c361624d-3f16-4891-9e29-7eed9774cf94">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78efd284-51a8-4fff-b247-4984c6c10b86">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a4b3364-06dc-40e7-b361-36483cb66291">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56308830-2323-4fc3-b59e-d4f889e18fc5">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad839f1e-076f-4b1d-aa66-a984e12a0fb1">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_18d0a25a-78ea-46f7-ae04-fa9aef7844fb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_352d204f-e20e-41ab-b132-50584ef842dc">
                                <link xl:href="http://snomed.info/id/44132006" xl:show="new">44132006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_28f5911a-cb20-47df-a091-6be8dbf77ba7">Abscess</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19719d99-bffd-43d8-9775-57f296f9f4aa">
                                <link xl:href="http://snomed.info/id/44132006" xl:show="new">M-41610</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc1222fd-e3a0-4d9b-9ed0-a25ae695b9bf">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0000833" xl:show="new">C0000833</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_13b9ce5f-4d59-48d4-ae64-e101fc750fe2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7c6aefe2-b1d3-401a-9111-4aadd064f976">
                                <link xl:href="http://snomed.info/id/75753009" xl:show="new">75753009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_47704296-de19-481f-9722-6fb95b95e28e">Blood clot</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f94d8f27-0cd2-4850-9ac1-bf4eb1068d10">
                                <link xl:href="http://snomed.info/id/75753009" xl:show="new">M-35000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_94d7c08a-7ac4-42fc-8a18-55cfd376d69b">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0302148" xl:show="new">C0302148</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_abbfb316-bad7-41b0-a401-ae9e04e0cd93">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86a0bd89-a057-464e-ae47-7c78aa0c5fc9">
                                <link xl:href="http://snomed.info/id/367643001" xl:show="new">367643001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f11d9b33-1652-4a4a-95c2-9ccb81ca4da2">Cyst</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_362d3ab0-a5c0-4096-af2a-5e037be9a4a2">
                                <link xl:href="http://snomed.info/id/367643001" xl:show="new">M-3340A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2a02b2d-aa08-4cad-b8b9-e9ef705f64bc">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0010709" xl:show="new">C0010709</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0055f25f-b905-4fb0-98e4-3c1e2ef31817">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_246bfd64-2e37-4a30-9417-15a1c312cd13">
                                <link xl:href="http://snomed.info/id/79654002" xl:show="new">79654002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4fa99328-28cf-4c24-911a-6b8e5580276d">Edema</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3eb23ed1-e51b-481b-b827-b056754c2d1f">
                                <link xl:href="http://snomed.info/id/79654002" xl:show="new">M-36300</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7308cc8f-2a74-4ec8-af8c-b771a6b242ec">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0013604" xl:show="new">C0013604</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c746599-4ea9-4f39-93ff-f3154cafde15">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_618e2de5-285d-4247-b76d-ec0bc1efeeeb">
                                <link xl:href="http://snomed.info/id/55584005" xl:show="new">55584005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b4ced2be-07ee-4bfa-acac-0a5bb95a2b56">Embolus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de958931-2698-40a8-9caa-12e66535fcd9">
                                <link xl:href="http://snomed.info/id/55584005" xl:show="new">M-35300</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a2e97f2d-58ee-45b8-ab37-1382161b9741">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1704212" xl:show="new">C1704212</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a335382-c4b4-4216-8525-0ae139614dd7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d2d8c27-2034-4206-b253-4373b1e846ec">
                                <link xl:href="http://snomed.info/id/50960005" xl:show="new">50960005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_13927946-aa08-459b-8da0-d00767dd1d44">Hemorrhage</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_173eb5ba-6e98-42e1-8595-c516487f6ffb">
                                <link xl:href="http://snomed.info/id/50960005" xl:show="new">M-37000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f7f3f96-d574-41eb-9399-3bb8f694a040">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0019080" xl:show="new">C0019080</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_549455d9-df11-4da7-bb3e-75e82137ae55">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d4325cd-2123-4c14-b465-2bc590105e1c">
                                <link xl:href="http://snomed.info/id/409774005" xl:show="new">409774005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b0767a0d-ee52-45c8-bcd0-c22e12976a0c">Inflammation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d496b87f-5a0b-45bf-bd6c-0b8e6260f1b4">
                                <link xl:href="http://snomed.info/id/409774005" xl:show="new">M-0100C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_97ad421c-ab60-407e-a593-07d8ac245212">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1444073" xl:show="new">C1444073</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                    <link xl:href="http://snomed.info/id/52988006" xl:show="new"><emphasis role="bold"><emphasis role="underline">52988006</emphasis></emphasis></link>
                                </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Lesion</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                    <link xl:href="http://snomed.info/id/52988006" xl:show="new"><emphasis role="bold"><emphasis role="underline">M-01100</emphasis></emphasis></link>
                                </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                    <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0221198" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0221198</emphasis></emphasis></link>
                                </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_543a8342-6d2f-4462-b7f6-5944c9e50573">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4fbf23e6-89e5-4e65-993c-d17f49223497">
                                <link xl:href="http://snomed.info/id/4147007" xl:show="new">4147007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cd13bfee-a257-41bd-9c41-745364bfc16c">Mass</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_30da2ffe-5e49-4f2b-9632-81ed03373071">
                                <link xl:href="http://snomed.info/id/4147007" xl:show="new">M-03000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24a88a55-0e49-4f90-8973-7277ef6acc4b">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0577559" xl:show="new">C0577559</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9516c69b-ed4b-47be-afe3-8834c0f802d3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_18d8aa84-9915-4dd4-986d-f9a317466c9e">
                                <link xl:href="http://snomed.info/id/6574001" xl:show="new">6574001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b2c274ca-9c71-4776-a1fe-5b7c30de453d">Necrosis</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_664a0027-d4f0-4317-9c9c-9a7ed7edaade">
                                <link xl:href="http://snomed.info/id/6574001" xl:show="new">M-54000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b95b3c74-43f1-4d03-b88c-f9607142bbf7">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0027540" xl:show="new">C0027540</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3574017-2576-42ca-b5c7-41cf97576994">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4aeb7ac0-e998-4d78-8d21-fa739ec105d3">
                                <link xl:href="http://snomed.info/id/108369006" xl:show="new">108369006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_203db3e4-017a-481c-b153-3b92d6236df9">Neoplasm</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3bae22f1-33e8-4429-8ba2-df6ca4be29cc">
                                <link xl:href="http://snomed.info/id/108369006" xl:show="new">M-8FFFF</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8fe3deb-d225-4c60-b713-988e6fa8e05b">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0027651" xl:show="new">C0027651</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c3b6b251-e2ed-4f90-9fa1-c8815d37ed72">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a5bf824c-fd85-43f3-856b-6bbfa08ecd12">
                                <link xl:href="http://snomed.info/id/86049000" xl:show="new">86049000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b2aaafc8-eecc-4d41-9ebc-73186c6e23f5">Neoplasm, Primary</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f87f6b9-91ef-4dbd-8e2d-2824846bb63e">
                                <link xl:href="http://snomed.info/id/86049000" xl:show="new">M-80003</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cefd0d29-cb2d-4633-b6d6-45273444aafb">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1306459" xl:show="new">C1306459</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a8b3e95-4d07-4e6b-bc7c-5063302f080a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e69e75f-5096-49b0-a1af-a71badb28654">
                                <link xl:href="http://snomed.info/id/14799000" xl:show="new">14799000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d9c74878-06dc-4757-886f-ac48826f2f12">Neoplasm, Secondary</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_05d3e9a2-faf4-4122-9b5e-d0817cf5cf12">
                                <link xl:href="http://snomed.info/id/14799000" xl:show="new">M-80006</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e0b61f5-a082-4d87-9eb1-72dd4de23f36">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2939419" xl:show="new">C2939419</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58203c7b-4936-47f5-b511-56f70483764c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1178a27-a39a-4eea-8949-6d87366ee13a">
                                <link xl:href="http://snomed.info/id/27925004" xl:show="new">27925004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_eae74b19-05a8-4139-bb1e-cbcc886bfe2d">Nodule</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b432597-d204-4d5e-8ad9-3f52fadd9651">
                                <link xl:href="http://snomed.info/id/27925004" xl:show="new">M-03010</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_698e5774-1b45-4c5d-9d07-d36517953d10">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0028259" xl:show="new">C0028259</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_05ac044a-4e4b-42dd-a10b-50628bed7b31">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7168" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="CID 7165" status="3" xml:id="sect_CID_7165">
            <title>Abstract Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5ec35d24-e3d3-4cc6-b24b-2d684792f229">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7165.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7165.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7165.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.962.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_220eb06b-c564-4139-bcac-0e274e63f85b">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_005e75d8-afe8-4b7a-9b63-70448c857010">
                                <emphasis role="bold"><emphasis role="strikhthrough">20190327</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                            </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_06e531b7-9cdb-4d92-84a4-a6375fc86e96">
                            <emphasis role="bold">1.2.840.10008.6.1.962</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7165" rules="all" xml:id="table_CID_7165">
                <caption>Abstract Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e571185d-29d6-4fca-a1fd-0916cff4a7df">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0f62517-6c6c-4d8b-af0a-ee09f0617da1">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb1a83dc-ff1e-4cc4-8d03-417aa4c48bc6">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_77cdabc8-83ab-4867-8ff9-eadd1cd71583">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0f0971b-cd40-4275-9244-8ad7129ec07e">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4d6663b-fb75-44ea-bcfb-cce6541e42a2">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6a01981-ff93-4623-af3f-5695b7cbfbd8">
                                <link linkend="DCM_125040" xrefstyle="select: nopage">125040</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b3d8ec0d-f176-44b8-8950-dbcb84a97895">Background</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6dfb3647-f08d-4776-91f7-afd3614958c2"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8651ae03-b69f-49c7-b980-b8670342790d"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06d30d2a-f78f-4f65-b51f-6cf569442841">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9571e3f3-495e-4941-87eb-f38808f24c8d">
                                <link xl:href="http://snomed.info/id/85756007" xl:show="new">85756007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3516fdc7-c20c-4d0c-9e02-94eea781c407">Tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83e44d96-16db-4ab3-9bf5-d90c1ff7a65f">
                                <link xl:href="http://snomed.info/id/85756007" xl:show="new">T-D0050</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3b1192a-5475-4b59-a119-cecbc2737118">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0040300" xl:show="new">C0040300</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">DCM</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                    <link linkend="DCM_ddd001" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">ddd001</emphasis></emphasis></link>
                                </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Tissue not of interest</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_30c75ef1-5499-4ee7-8154-823e8594c35b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6970d7b2-dc89-4b10-aea3-576318b3efa4">
                                <link xl:href="http://snomed.info/id/289925000" xl:show="new">289925000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_63e541f3-bb54-439e-9c6a-6b98315c48b0">Waste Material</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6fd9c956-5852-4c49-8b17-d8136533e38c">
                                <link xl:href="http://snomed.info/id/289925000" xl:show="new">F-61779</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ea59d69-f3d5-4754-ae9f-ac09a79ce30e">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0043045" xl:show="new">C0043045</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58bae4cc-672b-4d65-90e7-bd777eed3719">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_273e0355-d9e3-4798-92fa-2797bd10022d">
                                <link linkend="DCM_125041" xrefstyle="select: nopage">125041</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6daaf652-c38c-47ff-9a77-7969ff2b6bf7">Registration Input</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8d4baef-4ecb-4d83-b39c-ec69269c7766"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_52321a07-9e31-40bf-96de-d06c1360852d"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_396b9fc2-c879-4314-92df-6b9ebcc047e2">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9b61d8d1-9f32-45bc-a90d-70ecee1ad81d">
                                <link linkend="DCM_113132" xrefstyle="select: nopage">113132</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_43c34797-7ec0-45b2-82bd-ce91bcc4ca71">Single subject extracted from group</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e32176a7-a5cc-4966-9874-1d21dad65ebb"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_23b939f0-18d4-46d5-84cc-c8b4f0ddffea"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7afa073c-2fa2-41cf-85a8-aa4d5e4c3ac1">NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b08b860a-7cb2-449c-964e-94bfde0a9527">
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C94970" xl:show="new">C94970</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e236dc01-226c-40bf-9965-8680964709c3">Reference Region</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a2d9d14-d3ef-4265-aa3a-94b995daa9f2"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_457447b8-638c-4c2e-85ca-edee7cbaf417">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2986814" xl:show="new">C2986814</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8f5727a-0a46-42d3-99de-63bbbcf263ca">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80f26431-f0fb-4357-9407-e51f4271e2a3">
                                <link xl:href="http://snomed.info/id/17621005" xl:show="new">17621005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_18b7f84e-3a0d-4b90-b5fc-c0a59281927a">Normal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ab50ecfe-918c-4353-80b4-1e7cdd5d34c3">
                                <link xl:href="http://snomed.info/id/17621005" xl:show="new">G-A460</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50b8a69b-2799-4a5a-bd79-c5bff3f119d5">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0205307" xl:show="new">C0205307</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <para xml:id="para_5d14544b-81c5-41f8-87e6-cd59e0fe5583">The concept <link xl:href="http://snomed.info/id/17621005" xl:show="new">(17621005, SCT, "Normal")</link> is a general normality qualifier used here to mean normal in the context of the structural or functional image being segmented, whether it be "normal tissue" or "normal function". Normal may be distinguished from background (e.g., where there is no tissue at all).</para>
            </note>
        </section>
        
        <section label="CID 7166" status="3" xml:id="sect_CID_7166">
            <title>Common Tissue Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a5db6324-9a7b-44e7-9f47-0d743f75b387">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7166.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7166.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7166.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.963.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5d0431aa-23ad-4b72-9a77-4f90182de9e3">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_04355deb-fe56-48c6-807e-fca6950b8bed">
                            <emphasis role="bold">20200921</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_113cd489-f308-4493-9041-60afe15f8b0c">
                            <emphasis role="bold">1.2.840.10008.6.1.963</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7166" rules="all" xml:id="table_CID_7166">
                <caption>Common Tissue Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_226e8e9b-5c9a-4d59-b15b-2164ddd17b54">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9a4d1dd1-2c57-485d-911d-aa30651d8f7c">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d211ac5-2fe9-4c27-b21d-8816c89171d1">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0dc66fe-3bd4-431d-88b6-08a4bb41a469">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ef95191-e073-4f82-bcc2-4973634a09a0">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40bb4fc8-b2c1-452b-9740-decbfa73b7e3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e14d21c8-adde-4a49-8dbd-c78bc174e9aa">
                                <link xl:href="http://snomed.info/id/51114001" xl:show="new">51114001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a76991e6-61c3-42da-a7b3-d0a6ce4145c2">Artery</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0cec746-86a1-4c30-9712-7d2a482b0674">
                                <link xl:href="http://snomed.info/id/51114001" xl:show="new">T-41000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21931f5c-2d33-47fb-9b43-34de6a675945">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0003842" xl:show="new">C0003842</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cef3cc19-b66e-4842-8ca2-bf78912c9d4d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d20e3b3-2a6a-4dee-8748-cdbf246c177b">
                                <link xl:href="http://snomed.info/id/87612001" xl:show="new">87612001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aeff2818-1fbb-4def-8f89-da650ca83cf0">Blood</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9777745-8f3f-4906-9bf8-acadb3b9ba17">
                                <link xl:href="http://snomed.info/id/87612001" xl:show="new">T-C2000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_507a7572-37fb-4215-af44-8fda34ce7821">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0005767" xl:show="new">C0005767</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f27fd652-afdf-4b09-bb8b-8edbbe8e12ac">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a20d04eb-8d21-44ad-b14d-03a3e42eb0bb">
                                <link xl:href="http://snomed.info/id/59820001" xl:show="new">59820001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9d777c6a-e2f4-4594-b692-81666f9cc1c7">Blood vessel</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db58823b-e93b-469d-ab90-cc5fd63fc7c0">
                                <link xl:href="http://snomed.info/id/59820001" xl:show="new">T-40000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_911116d2-4f39-48b1-97e5-0279c2461056">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0005847" xl:show="new">C0005847</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f4cde15c-2bcb-4f7e-accc-cf95d0de77e1">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6c53b07-5f69-40cb-8ed5-17ef6cbecf6c">
                                <link xl:href="http://snomed.info/id/248300009" xl:show="new">248300009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4a2b12c7-fcd4-4107-a115-f4247fa54d26">Body fat</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_635cb458-5ee9-49f8-9baf-ff3583a4cf08">
                                <link xl:href="http://snomed.info/id/248300009" xl:show="new">F-03D38</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b395f8da-e211-499e-9a65-e5fef673fac3">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0344335" xl:show="new">C0344335</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df78a135-fba3-46e5-93f2-3ac0c3dd6351">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a0aefe24-4385-4850-ac23-5b957b86ee72">
                                <link xl:href="http://snomed.info/id/272673000" xl:show="new">272673000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_15543707-51f6-4513-ac99-fe4d3eaa2fe7">Bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b16fa08c-39b1-4e13-aaea-84340ee41739">
                                <link xl:href="http://snomed.info/id/272673000" xl:show="new">T-D016E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6803ae5-8939-4cd9-8507-4427d13c5ceb">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0262950" xl:show="new">C0262950</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_877e6279-fb06-4287-a9ad-1d0d66ea58ab">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5e5a2ca-1bf7-4366-a76c-d545e49f6aca">
                                <link xl:href="http://snomed.info/id/20982000" xl:show="new">20982000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ab4b12ec-954c-4646-9579-7387e9a291fb">Capillary</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ee5b6868-c3e7-4cb3-b4c3-1d0dafb76b4c">
                                <link xl:href="http://snomed.info/id/20982000" xl:show="new">T-40050</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_093da5bf-b379-4035-841b-7ac96524b547">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0006901" xl:show="new">C0006901</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a296743-4e8a-47eb-a68b-425c6009dde0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60f9ce68-399f-4cb7-a4e0-ca60866b3050">
                                <link xl:href="http://snomed.info/id/309312004" xl:show="new">309312004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_66d7bf56-09c8-4037-8b91-0bfc89bd848b">Cartilage</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8f669aea-7c8f-4f1b-aba6-dbfdea8f9992">
                                <link xl:href="http://snomed.info/id/309312004" xl:show="new">T-D021B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62dee049-2718-4644-baf6-eda086dd7d44">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007301" xl:show="new">C0007301</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ebbe11b-bddb-4eac-a5ab-124836753051">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d8e874e7-acc0-4937-ac03-a66dee9c0006">
                                <link xl:href="http://snomed.info/id/21793004" xl:show="new">21793004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b440813b-6105-4cae-8afd-08b7daf652c7">Connective tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9d163e2-e76a-4c2a-ba53-6ad5076282e1">
                                <link xl:href="http://snomed.info/id/21793004" xl:show="new">T-1A200</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89084d1f-875e-4841-811b-e441832ee603">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0009780" xl:show="new">C0009780</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a79e57db-3c10-4b2e-8afe-100a5e672034">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a99502bd-c1b1-4d49-8515-e5c52ae0edab">
                                <link xl:href="http://snomed.info/id/52082005" xl:show="new">52082005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4950bcf1-b3a5-427a-85da-9483d596491b">Ligament</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_edc7407a-2e0a-4c4b-8b4b-599ffe5f4c77">
                                <link xl:href="http://snomed.info/id/52082005" xl:show="new">T-18010</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ced0249a-f711-4e6b-9773-cecbfe232d40">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0023685" xl:show="new">C0023685</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ed241471-077f-42a6-8bbf-5fcfb9192e14">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1cbffe0-a0c1-4eb5-b697-05103ac997cf">
                                <link xl:href="http://snomed.info/id/59441001" xl:show="new">59441001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_192074b7-8ca9-40c3-a5c9-c789d4e4b744">Lymph node</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3af09aa2-9ec2-4807-b3f7-b36549aa271f">
                                <link xl:href="http://snomed.info/id/59441001" xl:show="new">T-C4000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b719d6d6-9bc4-4153-bb90-290fde229b44">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0024204" xl:show="new">C0024204</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd77d88f-aecf-4084-8d15-805796e4305e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9193ec80-ab95-494d-986e-13e04c62e118">
                                <link xl:href="http://snomed.info/id/89890002" xl:show="new">89890002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f2a0c67c-8ff1-451f-aa98-1f8ee76ca02c">Lymphatic system</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3035ece5-df40-41dc-b047-bc6455cbd1ed">
                                <link xl:href="http://snomed.info/id/89890002" xl:show="new">T-C6000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0b160b7f-b586-4f08-a0df-420aab789fa7">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0024235" xl:show="new">C0024235</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c708902c-5800-48ae-810b-ec2cd483627e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc09bfec-29c6-4770-a743-0bdb8f7726f7">
                                <link xl:href="http://snomed.info/id/83555006" xl:show="new">83555006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_76894835-f0d0-4adb-949d-62bd5a910aa0">Lymphatic vessel</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bcb65d6d-110a-46f3-92dc-4d073824d2e8">
                                <link xl:href="http://snomed.info/id/83555006" xl:show="new">T-C6010</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5c8fa37e-2017-47e0-95a2-860bf749fdae">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0229889" xl:show="new">C0229889</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_32775289-ae22-4a10-aaa5-708186b60122">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3977f3ac-a3ab-4c2e-a965-865d064d6ada">
                                <link xl:href="http://snomed.info/id/74135004" xl:show="new">74135004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_197c917a-6bbc-4d96-9bff-2e0d1bd0ae56">Meniscus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f4f8f4d3-f0a6-4b6b-9268-057d42dcbd4a">
                                <link xl:href="http://snomed.info/id/74135004" xl:show="new">T-15009</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e55dcad-1a97-491a-b562-33dbcd4fbfb1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0224498" xl:show="new">C0224498</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_610ec4a8-e467-4583-968f-0c4c46ec8a2b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9c3f151-6269-4155-9b4c-7ae711ff5104">
                                <link xl:href="http://snomed.info/id/71616004" xl:show="new">71616004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_80568543-a9ea-4c0a-ae19-c01e514ff9c5">Muscle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af737868-8ebe-45a7-b600-a1f8e712f532">
                                <link xl:href="http://snomed.info/id/71616004" xl:show="new">T-13001</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11ec9506-82bb-4e5e-a067-8e7d2e9fd5e6">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0026845" xl:show="new">C0026845</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_01264865-bb7c-444f-8215-4fad6358cf30">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22a0028e-9f9d-4014-bbbc-1fde26cf5950">
                                <link xl:href="http://snomed.info/id/119410002" xl:show="new">119410002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4152b59f-2123-478c-92c4-85d5c1b98bc5">Nerve</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0e51eb6c-2277-40a6-b80d-6ab08efab035">
                                <link xl:href="http://snomed.info/id/119410002" xl:show="new">T-D0598</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c5da668d-f05d-4919-a4a6-932fa381f360">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1268169" xl:show="new">C1268169</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fcb40137-060d-4222-89f5-2fd56e7e9edb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e60c325-585c-45fa-87e0-7ae2613e86d0">
                                <link xl:href="http://snomed.info/id/113343008" xl:show="new">113343008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5f748273-63f4-4069-ba88-a068cf546b1f">Organ</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2fe6b1c5-15cf-4b80-b004-2b5a99519d2f">
                                <link xl:href="http://snomed.info/id/113343008" xl:show="new">T-D0060</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0cdff002-dfc7-4459-bc6a-b7210a220e6a">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0229983" xl:show="new">C0229983</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e2607d8-2dde-40d5-9536-3b2a791b8737">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb8c6270-0091-4f2a-91c5-72d68d343612">
                                <link xl:href="http://snomed.info/id/39937001" xl:show="new">39937001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3948a545-d41d-4832-b256-492191f57347">Skin</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a81313f-27f6-412f-b408-a4019114e3b0">
                                <link xl:href="http://snomed.info/id/39937001" xl:show="new">T-01000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_484b166a-018d-4ebf-ad5c-dc03ec7ff294">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1123023" xl:show="new">C1123023</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b392fcd0-9774-44f7-b6d3-a580b5da66f7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20a4ea19-c499-447d-88a0-d95198bb195f">
<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=87784001" xl:show="new">87784001</link>
</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4587f2a5-dfdd-4e9a-a841-eac9776ec5ba">Soft tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_120a2b9f-3fa8-441f-a30e-a409bb26edfb">
<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=87784001" xl:show="new">T-1A000</link>
</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dd1adec6-a233-4c0d-b0d3-c214ba337736">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0225317" xl:show="new">C0225317</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fbd41c21-7029-403b-acdd-c973d69fad97">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d181805-4ad1-4ee8-aad9-764209c5fc37">
                                <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=71966008" xl:show="new">71966008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f9593944-f38c-4667-a50c-656c92965a12">Subcutaneous tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06414aa3-586f-4a69-a3b0-cc70a6f97c1d">
                                <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=71966008" xl:show="new">T-03000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_442ae46e-17c9-4a2d-a218-da526f72f447">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0278403" xl:show="new">C0278403</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_95164e27-3b77-4a14-a6f2-3bb1387c8500">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_009289cd-0f10-43ae-8f8c-b40a7a092dbe">
                                <link xl:href="http://snomed.info/id/13024002" xl:show="new">13024002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5e4b32aa-81cb-4266-a996-ef8b99ffc6c6">Tendon</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d5c49372-13bb-4995-b8b0-a8b4dd7051b7">
                                <link xl:href="http://snomed.info/id/13024002" xl:show="new">T-17010</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_745cba8a-424a-40c8-b160-6724d3ad7c73">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0039508" xl:show="new">C0039508</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c33684e6-29db-4870-92fd-23bbf79d7b4a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0aa0e93-e007-4ee4-a4e7-8e8c9fa3d3d4">
                                <link xl:href="http://snomed.info/id/85756007" xl:show="new">85756007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_946b0cb6-c4e7-4d74-9b62-2e9238a944c3">Tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0e06f87c-9153-4b07-ba9b-8319163e4cf6">
                                <link xl:href="http://snomed.info/id/85756007" xl:show="new">T-D0050</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d719cc86-0bc5-4bd8-948e-1c5ff462be0e">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0040300" xl:show="new">C0040300</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_81a5ffc4-a9f9-4889-9560-6c3e54f3524f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c3ae4dc-c7a8-41ec-801b-19e28b4a586b">
                                <link xl:href="http://snomed.info/id/29092000" xl:show="new">29092000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_26683fee-872d-41ba-b8d2-b04b9d847764">Vein</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f169af39-9072-4d8f-860d-b3033c40b761">
                                <link xl:href="http://snomed.info/id/29092000" xl:show="new">T-48000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_31a7e39e-7ef1-4d03-b473-b8a11ab22941">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0042449" xl:show="new">C0042449</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <para xml:id="para_5ce60564-f129-43b6-bd91-51bdeaaa33e6">Blood and body fat are considered tissues rather than body substances because they are cellular.</para>
            </note>
        </section>
        
        <section label="CID 7168" status="3" xml:id="sect_CID_7168">
            <title>Brain Lesion Segmentation Types With Necrosis</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a901accb-8a70-4327-a265-9969bb4c7b74">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7168.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7168.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7168.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu1.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_e43a6f38-ce63-4e45-b8a1-4d3977d3c02a">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_8968f42e-b1e5-419a-9c04-f3dc70fa8ea2">
                            <emphasis role="bold">20190327</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c2a7ea96-5d1c-49d2-adf6-3998f0f18c08">
                            <emphasis role="bold">1.2.840.10008.6.1.1280</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7168" rules="all" xml:id="table_CID_7168">
                <caption>Brain Lesion Segmentation Types With Necrosis</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc642a3a-fd19-4c8a-a69c-70969a2c93fb">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59909a64-95c0-466e-a537-8d092d38cec4">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_970bfe2a-718d-4761-9481-8537179f9858">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dfdd9566-094a-4194-ae50-ba1c65926e74">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f2e1a37-57ab-4add-bf18-7d800ec8fc22">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_8a18a357-aae1-4e1f-8769-f688e6663e34">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7169" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fcc0c0af-d8c8-4d53-9c8f-097a5f66dcc1">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c61e073e-e5cb-4a44-97d7-74f70acb7636">
                                <link xl:href="http://snomed.info/id/6574001" xl:show="new">6574001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_50450d5c-e9a3-47a9-a112-cdccf8561ab0">Necrosis</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a847204d-7b63-4fac-b66c-ae9fc2b9ceec">
                                <link xl:href="http://snomed.info/id/6574001" xl:show="new">M-54000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eaacaa6a-0c12-4765-8a41-75ea6a1e9a9a">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0027540" xl:show="new">C0027540</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <para xml:id="para_10383cef-e230-4824-919d-636d13fb4c5f">The same concept for non-enhancing tumor is used in this Context Group and when included in <xref linkend="sect_CID_7169" xrefstyle="select: labelnumber quotedtitle nopage"/>. When used in this Context Group, non-enhancing tumor excludes any necrotic region, whereas when used in <xref linkend="sect_CID_7169" xrefstyle="select: labelnumber nopage"/>, it does not.</para>
            </note>
        </section>
        
        <section label="CID 7169" status="3" xml:id="sect_CID_7169">
            <title>Brain Lesion Segmentation Types Without Necrosis</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c1c6c875-034e-46d3-af23-1e5eddad6cc8">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7169.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7169.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7169.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu2.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_faeb89dd-188c-42ea-bf5a-51861959290a">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_31169ab6-e1c7-41d9-ad94-76348b338c4c">
                            <emphasis role="bold">20190327</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_7531ed8b-e700-4ddf-9102-999f6a55fa97">
                            <emphasis role="bold">1.2.840.10008.6.1.1281</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7169" rules="all" xml:id="table_CID_7169">
                <caption>Brain Lesion Segmentation Types Without Necrosis</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_456446de-5f7c-4ebb-8274-22935f2ba891">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57eff057-7954-424d-85b4-5158ce9d3b64">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d34f8900-e392-4936-b627-32291d421a4e">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ee4baba9-b1cf-4f22-9e80-72d222d0acd1">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cca59486-6bf3-49ba-81a5-bfda30ce1787">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d512fc8-eacf-4e0b-b4a0-7c0fa9f26f73">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a58b79b-21cc-48cb-8abc-46e6fb72f11f">
                                <link linkend="DCM_125040" xrefstyle="select: nopage">125040</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f3e46397-b507-45ae-a8fa-2928a062a2da">Background</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1dbbf6a-4152-476a-95eb-9ec462cef0d4"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_61b6793e-0cb6-4703-9e9b-aa3af370c17c"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fd38aec1-8518-4bbf-9a51-8335206241ae">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f894971-1912-4770-9211-1f4e8c31a44e">
                                <link xl:href="http://snomed.info/id/17621005" xl:show="new">17621005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cd6d0e40-a44f-460b-a89e-009cff7a36b8">Normal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bf73928e-c49d-4e8e-ae96-c197c4a0b5fb">
                                <link xl:href="http://snomed.info/id/17621005" xl:show="new">G-A460</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37f555ae-a98b-49e3-a5bf-3c5fd4aa4052">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0205307" xl:show="new">C0205307</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1e9ee36-b322-431f-b0e4-766e6f33bffa">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46505dc3-714e-4f53-ab92-3795dd3fd49e">
                                <link xl:href="http://snomed.info/id/79654002" xl:show="new">79654002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ea3eb21f-3ae8-41a9-af53-1e07e0414aa9">Edema</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc7774f9-9e66-46da-9d00-15f3123ea339">
                                <link xl:href="http://snomed.info/id/79654002" xl:show="new">M-36300</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5c93c838-1ff7-4b79-b8d8-00486219cb74">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0013604" xl:show="new">C0013604</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_35667b26-9484-41cb-8412-bb642cc346bd">NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a326d57e-c0a9-44ef-a756-2c23fe6442b7">
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C81175" xl:show="new">C81175</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_37b2e462-9693-487e-b1f9-443d469f422f">Non-Enhancing Lesion</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a66f888-94b4-449a-921a-aaf6a7f41b2c"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b842b7af-19fb-4cce-b4b7-e0362c121476">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2825493" xl:show="new">C2825493</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8ee8e64-3c7a-4f88-b3c2-3720f65778e9">NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_74327d68-da63-4023-b641-4a3bfdc7fff6">
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C113842" xl:show="new">C113842</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a30bab8c-8633-4331-84a5-586c26e8826d">Enhancing Lesion</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bdc6c95d-9edd-45ad-a237-500570916801"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8eff2ea8-dc37-4db6-a872-ee73b311cc8b">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C3830314" xl:show="new">C3830314</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <orderedlist>
                    <listitem>
                        <para xml:id="para_dfb6e772-f55f-4e9c-a36e-779d03c900de">The concept (17621005, SCT, "Normal") is a general normality qualifier used here in context to mean normally appearing brain tissue on an imaging study. Some coding schemes contain more specific concepts such as "normal tissue" (but may be part of a coding scheme for histopathology rather than imaging) or "normal brain" or "normal white matter". Normal may be distinguished from background (e.g., where there is no tissue at all).</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_dc63bc00-a658-4fde-b75f-9d011785712c">A generic concept for edema is used for consistency with other segmentation-related Context Groups, rather than a more specific anatomy or tumor-related concept such as (C121674, NCIt , "Peritumoral Brain Edema") UMLS:C4054192.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_5266b241-7b18-4370-a21a-b1dd02413836">The same concept for non-enhancing tumor is used in this Context Group and when included in <xref linkend="sect_CID_7168" xrefstyle="select: labelnumber quotedtitle nopage"/>. When used in this Context Group, non-enhancing tumor includes any necrotic region, whereas when used in <xref linkend="sect_CID_7168" xrefstyle="select: labelnumber nopage"/>, it does not.</para>
                    </listitem>
                </orderedlist>
            </note>
        </section>
        
        <section label="CID 7194" status="3" xml:id="sect_CID_7194">
            <title>Morphologically Abnormal Structure Segmentation Property Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_26b362c3-b2ad-4e24-9d20-99b75e8fae37">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7194.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7194.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7194.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1193.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_e31fe5ce-2f45-4d02-962d-809df26fb59a">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a5c6c063-4280-4642-8c39-c6ee94b12434">
                                <emphasis role="bold"><emphasis role="strikethrough">20170914</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                            </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_3a2a1722-f2bd-4941-9b05-3ca491357236">
                            <emphasis role="bold">1.2.840.10008.6.1.1193</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7194" rules="all" xml:id="table_CID_7194">
                <caption>Morphologically Abnormal Structure Segmentation Property Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6736f0d7-1cee-4e88-8c00-9f0210fff097">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2f3dcf3-8c60-473c-aa0c-6e76c217ee18">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa317fb5-789d-4afa-aabc-912fd00a93ae">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_07801d49-167b-4708-b5d2-22eddadacec3">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2912ff2-2199-4254-89f8-9522b56fa30f">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_acd6515d-811f-4f73-ae61-0a5eef1a57ec">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7159" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para>
                                    <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_cccc1" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                            </emphasis></emphasis></emphasis>
                                </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        
        
       
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">Definition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">Notes</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_125040">125040</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1b754389-0270-439c-8c8d-c2712837de5e">Background</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6ecb099f-b117-4b81-8dfe-93e9fe7ee507">That which is not part of an object.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bec0855f-4989-4f57-b312-7525bf27a7e0">E.g., background of an image (that which might be encoded with Pixel Padding Value, or a Segmentation Property Type.</para>
                        </td>
                    </tr>
                    
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_ddd001"><emphasis role="bold"><emphasis role="underline">ddd001</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="underline">Tissue not of interest</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="underline">Tissue that is other than that of interest for the purpose of the task.</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1"><emphasis role="bold"><emphasis role="underline">
                                        <para>E.g., segmented non-brain tissue in an image where the primary purpose is to segment the brain and/or its structure, and non-brain tissue that is distinct from background needs to be identified.</para>
                                    </emphasis></emphasis></td>
        </tr>
                </tbody>
            </table>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr><td><para><emphasis role="italic">Add new Context Group UIDs to DICOM PS3.6 as follows:</emphasis></para></td></tr>
        </informaltable>
        
        <table frame="box" label="A-3" rules="all" xml:id="table_A-3">
            <caption>Context Group UID Values</caption>
            <thead>
                <tr valign="top">
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3322bcc5-7ea4-44d1-9b17-499a6a5e512c">
                            <emphasis role="bold">Context UID</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_225c7fe6-91ef-424b-812b-249ecd55f194">
                            <emphasis role="bold">Context Identifier</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_25349958-e4d1-4bb0-aaa9-33d5cb03df93">
                            <emphasis role="bold">Context Group Name</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_21c2633a-2b79-49c4-baa8-d930649479d0">
                            <emphasis role="bold">Comment</emphasis>
                        </para>
                    </th>
                </tr>
            </thead>
            <tbody>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para>1.2.840.10008.6.​1.​uuu1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para>
                            <!--<olink targetdoc="PS3.16" targetptr="sect_CID_cccc1" xrefstyle="select: labelnumber"/>-->
                            <xref linkend="sect_CID_cccc1" xrefstyle="select: labelnumber"/>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para>
                            <!--<olink targetdoc="PS3.16" targetptr="sect_CID_cccc1" xrefstyle="select: title"/>-->
                            <xref linkend="sect_CID_cccc1" xrefstyle="select: title"/>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para/>
                    </td>
                </tr>
            </tbody>
        </table>
        
        
        
        
        
    </section>
  </chapter>
</book>
