    <title>CP-2116</title>
    <subtitle>More dates, times, datetimes and selector attributes need de-identification</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2021/03/25</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Joël Spaltenstein</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top">2021/02/26</td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2116</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: More dates, times, datetimes and selector attributes need de-identification</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.15</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Frame Acquisition DateTime, Frame Reference DateTime and Radiopharmaceutical Start DateTime and various other Date, Time and DateTime Attributes (including Version Attributes that do not have DateTime in their names, and retired Attributes that may still be used in Standard Extended SOP Classes) are not included in Table E.1-1.</para>
                    <para>Various Selector Attributes are also missing.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.15 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
     <section label="E.1.1" status="3" xml:id="sect_E.1.1">
                <title>De-identifier</title>
                <table frame="box" label="E.1-1" rules="all" xml:id="table_E.1-1">
                    <caption>Application Level Confidentiality Profile Attributes</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5e6e8ba-34e0-4e31-90b5-bd9ed7086ddd">
                                    <emphasis role="bold">Attribute Name</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d02d5580-8438-4a00-8c30-ba93530bcd31">
                                    <emphasis role="bold">Tag</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_705936dc-2c42-4198-b406-ba0e61b35e99">
                                    <emphasis role="bold">Retd. (from <olink targetdoc="PS3.6" targetptr="PS3.6" xrefstyle="select: labelnumber"/>)</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8387cac-386f-4ad9-96b3-b3dcb1b1010c">
                                    <emphasis role="bold">In Std. Comp. IOD (from <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>)</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc0ff9a1-5780-4d06-861a-24ae0ba38b47">
                                    <emphasis role="bold">Basic Prof.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19ddb67a-a5d6-474d-a13f-8df27d28b707">
                                    <emphasis role="bold">Rtn. Safe Priv. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b335431-5276-4cc0-bddf-93b6d107226e">
                                    <emphasis role="bold">Rtn. UIDs Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8317e0cf-0080-48f9-8040-1f49a4478c0f">
                                    <emphasis role="bold">Rtn. Dev. Id. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ba661a2-a572-420a-95c1-bc1bf694a70e">
                                    <emphasis role="bold">Rtn. Inst. Id. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_796841da-6b27-4558-99c9-99503edccc6c">
                                    <emphasis role="bold">Rtn. Pat. Chars. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edac8181-290b-4f9c-945d-5dfc7b1a43fc">
                                    <emphasis role="bold">Rtn. Long. Full Dates Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6305752d-56e7-4f4d-b9d8-e5052fcd6eea">
                                    <emphasis role="bold">Rtn. Long. Modif. Dates Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84f3b128-8fe5-45bc-b04e-abc483377b06">
                                    <emphasis role="bold">Clean Desc. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0adc5d55-1196-4265-8ee1-b205103c96f1">
                                    <emphasis role="bold">Clean Struct. Cont. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e74e547-b6fd-410e-9c09-b271915c3eeb">
                                    <emphasis role="bold">Clean Graph. Opt.</emphasis>
                                </para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Approval Status DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0044,0004)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Assertion DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0044,0104)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Assertion Expiration DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0044,0105)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Attribute Modification DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0400,0562)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Context Group Local Version</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0008,0107)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Context Group Version</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0008,0106)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Contrast/Bolus Start Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1042)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Contrast/Bolus Stop Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1043)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Contribution DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,A002)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Creation Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(2100,0040)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Creation Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(2100,0050)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A121)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Date of Document or Verbal Transaction (Trial)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A110)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Date of Last Calibration</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1200)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Date of Last Detector Calibration</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,700C)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X/D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Date of Secondary Capture</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1012)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A120)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">DateTime of Last Calibration</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1202)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Decay Correction DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,9701)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Digital Signature DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0400,0105)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Discharge Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0038,0030)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Discharge Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0038,0032)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Effective DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0068,6226)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Ethics Committee Approval Effectiveness End Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0012,0087)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Ethics Committee Approval Effectiveness Start Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0012,0086)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Exclusion Start DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,9804)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Findings Group Recording Date (Trial)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A023)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Findings Group Recording Time (Trial)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A024)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Frame Acquisition DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,9074)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Frame Reference DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,9151)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Functional Sync Pulse</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,9623)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Hanging Protocol Creation DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,000A)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">HL7 Document Effective Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,E004)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Information Issue DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0068,6270)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Instance Creation Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0008,0012)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X/D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Instance Creation Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0008,0013)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X/Z/D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Instruction Performed DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,9919)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Z/D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Intended Fraction Start Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(3010,0085)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Interpretation Approval Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(4008,0112)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Interpretation Approval Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(4008,0113)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Interpretation Recorded Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(4008,0100)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Interpretation Recorded Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(4008,0101)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Interpretation Transcription Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(4008,0108)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Interpretation Transcription Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(4008,0109)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Intervention Drug Start Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,0035)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Intervention Drug Stop Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,0027)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Issue Date of Imaging Service Request</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,2004)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Issue Time of Imaging Service Request</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,2005)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Modified Image Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0020,3403)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Modified Image Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0020,3405)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Observation DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A032)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X/D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Observation Start DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A033)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Participation DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A082)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Z</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Presentation Creation Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0070,0082)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Presentation Creation Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0070,0083)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Product Expiration DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0044,000B)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Radiopharmaceutical Start DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1078)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Radiopharmaceutical Start Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1072)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Radiopharmaceutical Stop DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1079)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Radiopharmaceutical Stop Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1073)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Referenced DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A13A)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Review Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(300E,0004)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Z</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Review Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(300E,0005)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Z</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Safe Position Exit Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(3008,0162)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Safe Position Exit Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(3008,0164)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Safe Position Return Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(3008,0166)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Safe Position Return Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(3008,0168)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Scheduled Admission Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0038,001A)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Scheduled Admission Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0038,001B)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Scheduled Discharge Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0038,001C)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Scheduled Discharge Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0038,001D)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Scheduled Study Start Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,1000)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Scheduled Study Start Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,1001)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Scheduled Study Stop Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,1010)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Scheduled Study Stop Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,1011)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector AS Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,005F)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector DA Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,0061)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector DT Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,0063)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector LO Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,0066)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector LT Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,0068)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector OB Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,0065)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector PN Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,006A)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector SH Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,006C)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector ST Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,006E)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector TM Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,006B)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector UN Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,006D)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector UR Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,0071)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Selector UT Value</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0072,0070)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SOP Authorization DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0100,0420)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Source Strength Reference Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(300A,022C)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Source Strength Reference Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(300A,022E)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Study Arrival Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,1040)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Study Arrival Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,1041)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Study Completion Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,1050)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Study Completion Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,1051)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Study Read Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,0034)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Study Read Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,0035)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Study Verified Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,0032)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Study Verified Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0032,0033)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Substance Administration DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0044,0010)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Template Local Version</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,DB07)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Template Version</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,DB06)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A122)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Time of Document or Verbal Transaction (Trial)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A112)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Time of Last Calibration</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1201)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Time of Last Detector Calibration</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,700E)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X/D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Time of Secondary Capture</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0018,1014)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Treatment Control Point Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(3008,0024)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Treatment Control Point Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(3008,0025)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Verification DateTime</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0040,A030)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">K</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                </tbody>
                </table>
            </section>
        
        
    </chapter>
</book>