<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2101</title>
    <subtitle>Clarify multiple frames used as tiles in planar ROI</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2021/01/12</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Markus Daniel Herrmann</para><para><link xl:href="mailto:MDHERRMANN@MGH.HARVARD.EDU"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/15/05</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2101</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Clarify multiple frames used as tiles in planar ROI</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Multiple frames may be used as tiles in planar ROI, rather than every frame being in a different plane as for radiology cross-sectional imaging.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
       <section label="TID 1410" status="3" xml:id="sect_TID_1410">
            <title>Planar ROI Measurements and Qualitative Evaluations</title>
            <para xml:id="para_47a24b81-ef09-41fc-b6aa-1cd54a1889dd">This Template provides a general structure to report measurements for some metric, e.g., density, flow, or concentration, and/or qualitative evaluations, over a planar region of interest in an image.
                The ROI may be specified by an SCOORD on an image, by a Segmentation Image, by an SCOORD3D defining an area relative to a 3D Frame of Reference, or by a reference to an ROI defined in a radiotherapy Structure Set.</para>
            <table frame="box" label="TID 1410" rules="all" xml:id="table_TID_1410">
               <caption>Planar ROI Measurements and Qualitative Evaluations</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_30b4aee0-ea2f-4145-8208-793586b42cc7"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e2114728-d791-431b-9191-bc8f10b33fb6">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ebe5dfb8-ae20-4bef-910d-06c15730b75b">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_11076f1d-2653-47e3-867d-98687bcf34d3">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0e28dd32-3fea-42af-ba33-fb3836638cf4">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b53dfca1-52dc-4c1a-86ae-6e7da6594631">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fdfbf0aa-9607-43d3-8888-66cb7b9ecd25">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_98188a1d-f8c2-4703-b93c-1bbbda3c1e56">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4191d21b-4639-4e6b-9acf-3961b18247e2">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d5a0bc4-a020-44ab-a211-f17a9fa83246">7</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dafa9592-2b76-411a-9dfb-b07bf3f4bdb5">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_37c5f744-ec7b-4ecc-96c5-ce5e33d14f03">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1e873d36-d3af-4f1c-9fd1-79cc437ae752">IMAGE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0840dc73-1210-4877-a6fe-5c287e00c5b6">EV <link linkend="DCM_121214" xrefstyle="select: nopage">(121214, DCM, "Referenced Segmentation Frame")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3c544407-674c-4954-98c4-405cae664c59">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2f37e245-08d0-46b3-b446-4b1b9955370b">MC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                         <para xml:id="para_7b26463d-cb66-40bc-a179-c245a1aa6541">XOR Row 5, 7b</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_24dd541b-fcbc-4cc8-9364-0a8fee6741cd">Reference shall be to a Segmentation Image<emphasis role="bold"><emphasis role="strikethrough">, with a single value specified in Referenced Frame Number, and</emphasis></emphasis> with a single value specified in Referenced Segment Number<emphasis role="bold"><emphasis role="underline">.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">For tiled images, one or more values shall be specified in Referenced Frame Number and shall select tiles in the same plane.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">For non-tiled images  a single value shall be specified in Referenced Frame Number.</emphasis></emphasis></para>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_12f34dea-c5d4-4127-b3fd-5f2adff0a8ef">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                   <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2babd6ee-8440-4df7-87f8-8cfc79a2f2e2">Rows 6, 7</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_48197dd3-b070-41ae-b65f-61265a57f1b3">Referenced Frame Number (0008,1160) is an attribute of the IMAGE Content Item, and shall be present with a single value.</para>
                        <para xml:id="para_6dab3616-4bba-44c5-92fa-571941f4ada2">If the Referenced Segmentation SOP Instance has Segmentation Type (0062,0001) value BINARY, it identifies the area of defined (measured) region of interest by pixel values in the referenced frame with value 1. For Segmentation Type value FRACTIONAL, the area is computed by an implementation dependent method.</para>
                        <para xml:id="para_f5322076-0cc8-427a-ab7b-a6f22534be34">Frame number shall be specified even if the Segmentation SOP Instance has only a single frame. <emphasis role="bold"><emphasis role="underline">It may reference multiple frames in the same plane for tiled Segmentation Images (such as segmentations of Whole Slide Microscopy images).</emphasis></emphasis></para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section> 

        
        
        
        

        
        
               
        
        
        
        
    </chapter>
</book>