<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2082</title>
    <subtitle>Add acquisition codes and template for fluorescence and immunohistochemistry in microscopy</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2022/04/25</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>IDC</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>2020/09/28</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2082</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add acquisition codes and template for fluorescence and immunohistochemistry in microscopy</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.6, PS3.16, PS3.17</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Immunohistochemistry involves a process similar to conventional staining but does not use traditional staining agents.
                        Instead it uses a substance (such as a monoclonal antibody) that is taken up by a receptor, to which is attached some means of visualizing that substance
                        (e.g., a chromogen, a substance, itself without definite color, which may be transformed into a pigment, or
                        a fluorophore, a fluorescent chemical compound that can re-emit light upon light excitation).</para>
                    <para>Accordingly, a new "Processing Type" of "Immunohistochemistry procedure" is added, with a corresponding templates and context groups to describe the "Component investigated" and the chromogen or fluorophore, as well as various other related attributes.</para>
                    <para>Also, it has become apparent that not all stains are valid substances, staining methods may involve complex processes and multiple substances, and SNOMED is invalidating these concepts, so DICOM needs to describe these by their technique code instead of a substance (that does not exist in the real world, e.g., an "acid-fast stain substance").</para>
                    <para>Also, when an excitation wavelength is not know, but it is known that fluorescence was performed, add a generic "narrow" (spectrum) value to use for the (required) illuminant.</para>
                    <para>Also, change all templates to make order not significant, since the interpretation of the content items is not dependent on their order.</para>
                    <para><emphasis role="italic">[Ed.Note: Using SCT:246094008 "Component investigated" rather than C25702,NCIt,"Target" .]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: ? use 406858009,SCT,"Fluorescent staining" rather than 117617002, SCT, "Immunohistochemistry", since not all fluorescent stains use antibodies (e.g., phalloidin (a toxin) for staining actin).]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Channel is allowed to be 1-n, but what does this mean (same step used for multiple optical paths, e.g., DAPI process repeated multiple times?) - should probably just repeat it.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: GH: Defined for IHE APSR; re-use codes (for DICOM Specimen Preparation Sequence Content Item) as TID 8001: Row 3: DCM:111701 "Processing Type" = SCT:117617002 "Immunohistochemistry procedure"; New Row: SCT:246094008 "Component investigated" (no children) (? SCT:259943009 "Cellular analyte" or SCT:259776003 "Immunology analyte" or SCT:259777007 "Immunochemistry analyte", or SCT:116647005 "Receptor" (which is parent of things like ER)) = SCT:23307004 "Estrogen receptor" (etc.). Need to make list of SCT components for receptors etc.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: CRS Request ID #nnnnnn to add to subset 703857004, 708056006, 246094008, 406858009, 117617002, 406979008 - sync with changes in SNOMED to technique (qualifier value).]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: CRS Request ID #769287 to add "Narrow spectrum" to use in place of generic qualifier value 134223000 "Narrow"]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: TBD. PS3.17 examples of DAPI-AT, Alexa 647 KI-67, HRP DAB KI-67, Alexa Fluor 350 Phalloidin, or similar]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: CRS Request ID #769280 - inactivate 406976001|Acid fast stain (substance) - SNOMED has also inactivated 67122001 | Acid fast stain method (procedure) and replaced it with 708056006 | Acid fast stain technique (qualifier value)</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Will need new technique (qualifier value) for Z-N (currently a procedure) (CRS#769280)]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Is there going to be a technique (qualifier value) replacement for 104210008 Hematoxylin and eosin stain method (CRS#769280)]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Will SNOMED retire 127790008 Staining method (procedure) (CRS#769280)? Replace with 703857004 | Staining technique (qualifier value) in template and context groups for now, to illustrate the impact of this upcoming SNOMED change.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note; Should just remove "staining" entry from CID 8130 Staining Protocols (rather than replacing 127790008 with 703857004), since otherwise just results in staining = staining, which is meaningless.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Should the removal/replacement of stain substances that are not real substances like 406976001 Acid fast stain (substance) (CRS ID#769280) be done in a separate CP?]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: TBD. Replace other uses of DCM codes for ER etc. with SCT.? separate CP]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        
        <section label="TID 8001" status="3" xml:id="sect_TID_8001">
            <title>Specimen Preparation</title>
            <para xml:id="para_c4365a93-570f-4d99-8525-25b31068c5fe">This Template describes a single specimen preparation step.</para>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_64f3ad96-5514-49f4-b944-7253995c5ced">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_1ac7c20d-78f9-4990-b187-6015f0dbd6c6">
                            <emphasis role="bold"><emphasis role="underline"><emphasis role="bold">Non-</emphasis></emphasis>Significant</emphasis>
                        </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_75ab5e52-b409-4a32-bf70-bfe321d48310">
                        <emphasis role="bold">No</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 8001" rules="all" xml:id="table_TID_8001">
               <caption>Specimen Preparation</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_35bea843-6064-4665-a18b-33324d700a20"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_20a81a6e-5ec1-4ab7-8781-3c6801a35b91">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_80c76678-4936-4e9c-bc5d-dd6408b081ec">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_02e3f65f-9283-452f-87b2-d20ce2412b4b">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_de3be3dd-e988-42d8-9a2d-afc8e01e5a21">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_faf72b56-4f3c-489b-bfc5-e34fbeb31fcf">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_13818311-b83c-4d85-a001-5fd9b818cb6f">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c4ad2d80-ef61-43ae-9ded-072282b70450">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_27fae3f8-ce30-42c8-801c-4fde4092f35e">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_911bdcd9-68c8-4d70-b7cb-988a6583e6ee">EV <link linkend="DCM_121041" xrefstyle="select: nopage">(121041, DCM, "Specimen Identifier")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_69ea33d3-cd87-4a5a-ade5-bb0e61a32a09">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1aa2b4dc-7494-406e-bbb0-e4a67a6a7d4f">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cd9d5877-accf-4959-87fb-6692fb0ecb40"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_32f9864c-f812-4b45-a82a-011f10e9c747"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7793136e-9d58-44ef-a030-8e964ad521a3">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dd603f2e-9d1a-4b76-9c51-eafccc7684a9">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_605a2f2e-806f-4300-a237-108ffa75cada">EV <link linkend="DCM_111724" xrefstyle="select: nopage">(111724, DCM, "Issuer of Specimen Identifier")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_758b4786-6bcf-4669-8ba9-da424da53652">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a8bcb41f-e828-485a-966f-68a302156e9d">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e6f0e9fd-3d5f-4ba2-b0c3-1d0b6cb46510"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a41c02f8-d35c-4e79-a3b4-81e129a3d20b"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d9b18251-7e2e-4030-826d-67379c7d36a8">3</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6354e858-27a5-4f98-b7ed-e34d806d6811">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3887bee0-9e13-4e4c-a03d-dd6529e28e6b">EV <link linkend="DCM_111701" xrefstyle="select: nopage">(111701, DCM, "Processing type")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_aa1e3dee-bda9-45e4-a41b-6920b79bc4c2">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7c407a99-b190-4300-8ac1-5f0e2eed9fe2">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5cd5631c-27dd-4761-8809-5a591e88d54a"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_74c2a23e-5ad9-41e9-b486-d603e4c0711d">D<xref linkend="sect_CID_8111" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fa268db5-ed45-41cd-8969-058f33a31d0c">4</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cfe8b5d3-5edb-435e-85f3-6738d3af470c">DATETIME</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_132f72d0-c3cf-4ab0-a1c3-b7b8d511384c">DT <link linkend="DCM_111702" xrefstyle="select: nopage">(111702, DCM, "DateTime of processing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d1f9b76d-b936-49d9-bbec-0e02a23fabae">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5c072485-57a8-479f-8cdb-342cc59a646a">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_44768508-eec3-4241-974f-a751bd5c7b85"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d86bdf4-5e6a-42b0-b71a-6ccc97627f96"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1a27ea6b-d162-4ac6-973f-f95d44707e64">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9efe9d99-3f4d-4ebc-841d-96169137932f">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c6676d2d-d32c-4c8d-b19f-05717363019d">DT <link linkend="DCM_111703" xrefstyle="select: nopage">(111703, DCM, "Processing step description")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_47bc4688-81b9-4cd1-a4f6-6637e7d38eca">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c42a30f0-e8fc-4aa6-9e21-7e462f3bebdc">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_76f733c2-48e5-428e-88d4-7b032d76c212"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c1b28735-2ed1-469f-a19c-e9216ba957ce"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_49e1eb7f-c49a-472a-a88b-f67c837dcfa8">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_98e4f078-1759-4640-beb8-ea7dce68f138">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bcc5ee6b-462f-41d2-b89f-a026d85cf740">DT <link linkend="DCM_111703" xrefstyle="select: nopage">(111703, DCM, "Processing step description")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3b9989b7-db50-4218-862e-74944b8636e0">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_03fa29a8-605b-4f9b-9704-da2b47027440">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dcda806e-2dcb-4394-9713-3ece924de82c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9e15ca07-e978-40ff-864c-6ed9a81146d6">D<xref linkend="sect_CID_8113" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">6b</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">TEXT</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">EV <link xl:href="http://snomed.info/id/255592004" xl:show="new">(255592004, SCT, "Channel")</link></emphasis></emphasis>
                            </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">1-n</emphasis></emphasis></para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para/>
                     </td>
                  </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">6c</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">TEXT</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">EV <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C25472" xl:show="new">(C25472, NCIt, "Cycle")</link></emphasis></emphasis>
                           </para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para/>
                       </td>
                   </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">6d</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">TEXT</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><link linkend="DCM_ddd003" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">EV (ddd003, DCM, "Subcycle")</emphasis></emphasis></link>
                            </para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para/>
                       </td>
                   </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para xml:id="para_163c7c16-cf63-4adc-9b7c-06fe32f9b2af">7</para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para xml:id="para_a05aa89d-48b9-4041-a5fc-87b21887ff69">CODE</para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para xml:id="para_45dc3020-5e39-4207-a9b9-e1104a292173">DT <link xl:href="http://snomed.info/id/17636008" xl:show="new">(17636008, SCT, "Specimen Collection")</link>
                           </para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para xml:id="para_d4b2e1f5-c72d-42d7-b71c-1a5bc7778866">1</para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para xml:id="para_16f4083c-a581-4e96-a1f8-c9d399f334fa">MC</para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para xml:id="para_24afbed2-f8df-475e-9906-dbd6d49d24ca">IFF Row 3 Processing Type value is <link xl:href="http://snomed.info/id/17636008" xl:show="new">(17636008, SCT, "Specimen Collection")</link>
                           </para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para xml:id="para_ee3c2913-daaf-4a7e-bfb7-0642dce797e5">B<xref linkend="sect_CID_8109" xrefstyle="select: labelnumber quotedtitle nopage"/>
                           </para>
                       </td>
                   </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para xml:id="para_bd95a952-2c8e-48fb-9ae4-e31b34b28641">8</para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para xml:id="para_482eebdc-f748-46a7-8756-4c932819c713">INCLUDE</para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para xml:id="para_06f60bdb-0bf1-4283-925e-f0f58456a0c6">D<xref linkend="sect_TID_8002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                           </para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para xml:id="para_84a3c007-26a1-4236-8866-3cd7b8c0f4a1">1</para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para xml:id="para_d7c8f515-e48f-4df2-b87b-cf027b4018f7">MC</para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para xml:id="para_9c40317b-a310-4473-840d-7519c6297909">IFF Row 3 Processing Type value is <link xl:href="http://snomed.info/id/433465004" xl:show="new">(433465004, SCT, "Specimen Sampling")</link>
                           </para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para xml:id="para_5ce4ef5b-d7c1-4a19-a074-a09e3b8809ae"/>
                       </td>
                   </tr>
                   <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1c12a9f1-d3bf-416f-b3eb-343382727f4f">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4ce11d43-0295-41e6-8f36-ad963c7d6cd5">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_664fe5e2-d53a-4613-925f-dc68988c60f5">D<xref linkend="sect_TID_8003" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4d3691c1-3a01-40cb-a63b-b7b73fcfcc34">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ffbd6a68-0ef1-419c-a7b0-c61a369899fd">MC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_59ecbc2e-dda8-4cf5-a75e-8b18142a6442">IFF Row 3 Processing type value is
                            <link xl:href="http://snomed.info/id/127790008" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">(127790008, SCT, "Staining"</emphasis></emphasis>)</link>
                            <link xl:href="http://snomed.info/id/703857004" xl:show="new"><emphasis role="bold"><emphasis role="underline">(703857004, SCT, "Staining"</emphasis></emphasis>)</link>
                        </para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a98a12e3-f196-4aca-96d3-b630508cd773"/>
                     </td>
                  </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">9b</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">INCLUDE</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">D<xref linkend="sect_TID_x8005" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                            </para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">MC</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">IFF Row 3 Processing type value is <link xl:href="http://snomed.info/id/117617002" xl:show="new">(117617002, SCT, "Immunohistochemistry")</link></emphasis></emphasis>
                            </para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para/>
                       </td>
                   </tr>
                   <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f4568fb0-d31b-4ec7-93aa-f4102134ecb7">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1c97945e-804c-4d7f-89f6-3203b3b4f621">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_72d323dc-91ac-42a1-bd01-a2127872839b">DT <link xl:href="http://snomed.info/id/430864009" xl:show="new">(430864009, SCT, "Tissue Fixative")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c888c9b4-b94f-4905-9d38-2284cb8acff5">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a65a74da-f5d9-43ec-b8e2-24c3af6d598a">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_32a37086-0546-466c-b7ae-272c3908a33f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bc0e6a77-f188-4cac-a6fa-57bef4be498e">B<xref linkend="sect_CID_8114" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5238eddb-4ef4-4cf2-90a1-c248ad796f8b">11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_757f276d-421e-40ef-9df1-8e1ffb09c2ec">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_003c24b8-cb28-41cc-bf98-91c8e986cab4">DT <link xl:href="http://snomed.info/id/430863003" xl:show="new">(430863003, SCT, "Embedding medium")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6b2780f3-d221-437d-b683-9514c7c08fb4">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_821a8c00-ddeb-424d-a6ce-60e76c48e687">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f4a2041a-5f1e-47c6-bad8-3ede6d9c4ca1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e6e89ad9-8a54-4c0a-b7a6-69e110a69d48">B<xref linkend="sect_CID_8115" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_79e1b4b9-1f83-4e38-b96c-329d4c046a7b">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">...</td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0162fbb1-184a-46ea-b844-f998c5343649"/>
                     </td>
                  </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Row 6b</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">May be used to indicate which Optical Path Identifier (0048,0106) value(s) in the image corresponds to this processing step, such as when different substances with different fluorescent characteristics are used simultaneously.</emphasis></emphasis></para>
                       </td>
                   </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Rows 6c, 6d</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">May be used to describe in which cycle or sub-cycle of a multi-cycle procedure (e.g., successive cycle of clearing and staining) this step was performed.</emphasis></emphasis></para>
                       </td>
                   </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Rows 3, 9</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Previously, <link xl:href="http://snomed.info/id/127790008" xl:show="new">(127790008, SCT, "Staining method (procedure)")</link> was used with the meaning "Staining", but has been replaced by <link xl:href="http://snomed.info/id/703857004" xl:show="new">(703857004, SCT, "Staining technique (qualifier value)")</link>.</emphasis></emphasis></para>
                       </td>
                   </tr>
               </tbody>
            </informaltable>
         </section>
        <section label="TID 8002" status="3" xml:id="sect_TID_8002">
            <title>Specimen Sampling</title>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_19f92109-b9ea-4a10-ab97-94a725729351">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_a79bd364-d1c2-49a2-9552-a645efdf6703">
                            <emphasis role="bold"><emphasis role="underline">Non-</emphasis>Significant</emphasis>
                        </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_329efbca-46f7-462a-8403-e9edad84c5fb">
                        <emphasis role="bold">No</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 8002" rules="all" xml:id="table_TID_8002">
               <caption>Specimen Sampling</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_549bb678-9dac-4423-a14e-c7fd3ceb744b"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_60f29a99-ab8e-4abe-ac4c-91511f54130c">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_98565fce-8a7f-431d-9e33-3e340d77f1b8">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_17a167df-9a9d-4291-8c20-d53cf2aef0db">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f5be70a1-258e-4ef0-aa24-7b229f0723a3">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4538d3dc-1b24-49b7-b426-8cc953cb1e05">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0f110527-bbb8-4188-8533-9ec22a8c0132">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6a970ff2-c0ae-4a7d-8bed-ef5276ecc027">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5c1b3c99-92e0-40ef-a1ae-fccfed31b03c">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6fafd691-f245-496b-b593-bc0c1409e120"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_468064f9-ef5a-45a8-99ea-ca57d0205400"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3dda7631-4d8e-42ba-9211-158437298bac"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cd99240e-5a67-4b42-b9e7-4b530ecf12f4"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b6d57135-8167-4358-9866-d9d7814a8e77"> </para>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>
        <section label="TID 8003" status="3" xml:id="sect_TID_8003">
            <title>Specimen Staining</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_191deb4d-e7eb-4611-87b7-bed4f4854f6d">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Order:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_951f5e42-44e2-4e31-81ea-6507d1dd46fe">
                            <emphasis role="bold"><emphasis role="underline"><emphasis role="bold">Non-</emphasis></emphasis>Significant</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Root:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_0d948b8a-16c3-4f5f-801b-567a88e508b2">
                            <emphasis role="bold">No</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="TID 8003" rules="all" xml:id="table_TID_8003">
                <caption>Specimen Staining</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7fde5b82-a9be-43d0-836b-53770a041150"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4e19545-49aa-45f0-8848-1869b0a97ac7">VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7e9a0b9-0c37-49c9-9869-75910cf4afa1">Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eec21473-a21c-4a67-86a2-da4670150b9a">VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f10542a1-3d34-405b-a2ad-fd16a54b7df2">Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_258f94fe-853a-4b4c-81f5-71c7d44b7084">Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f67cd29-5e01-4a9e-a78f-26377b0aeeff">Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e2e0b7f4-65f3-43cd-b039-2cd8d803516e">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4b16696e-fafd-4e50-ab4f-1b480776202a">CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_16a47d8f-0836-4b3c-86ec-8d0724eef711">DT <link xl:href="http://snomed.info/id/424361007" xl:show="new">(424361007, SCT, "Using substance")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2750f26c-6e5f-488d-8c7a-7a94160f3d99">1-n</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fafe30de-0480-45d8-b16b-4790cceae58f">MC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1238d700-98c5-43bc-8ff1-5accece7cc03">IF Row<emphasis role="bold"><emphasis role="underline">s</emphasis></emphasis> 2<emphasis role="bold"><emphasis role="underline">, 3, 4</emphasis></emphasis> not present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f4df2483-e570-463b-b435-edaabc78b95a">D<xref linkend="sect_CID_8112" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cff09821-fce0-4aec-a7c6-2fa5cfa3bce1">2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f6e1abdd-6fb7-4d30-a791-62e59470da94">TEXT</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a318dae4-d729-492d-90f0-dc87ce6d1dd2">DT <link xl:href="http://snomed.info/id/424361007" xl:show="new">(424361007, SCT, "Using substance")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8de2a30d-2a29-46fa-83aa-5bc6b4ab2009">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96774a96-64ab-429c-85db-845b1adb4c3e">MC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2a3c8902-8770-46f3-ac86-fb3409285304">IF Row<emphasis role="bold"><emphasis role="underline">s</emphasis></emphasis> 1<emphasis role="bold"><emphasis role="underline">, 3, 4</emphasis></emphasis> not present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_92a3fb74-07ec-4e4d-a6db-21868ed37632"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">DT <link xl:href="http://snomed.info/id/703857004" xl:show="new">(703857004, SCT, "Staining")</link></emphasis></emphasis>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">MC</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IF Rows 1, 2, 4 not present</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>D<xref linkend="sect_CID_8130" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">4</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">TEXT</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">DT <link xl:href="http://snomed.info/id/703857004" xl:show="new">(703857004, SCT, "Staining")</link></emphasis></emphasis>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">MC</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IF Rows 1, 2, 3 not present</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        <section label="TID 8004" status="3" xml:id="sect_TID_8004">
            <title>Specimen Localization</title>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_1b6a0974-3d12-47d5-9b8a-04c11ab06356">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_567314de-e3ab-454d-ab50-08abf6362cbb">
                            <emphasis role="bold"><emphasis role="underline">Non-</emphasis>Significant</emphasis>
                        </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_06566586-c088-457c-8100-fcf954d542b4">
                        <emphasis role="bold">No</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 8004" rules="all" xml:id="table_TID_8004">
               <caption>Specimen Localization</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e615ba5f-6223-45b6-882f-c433927811a8"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_734654f0-7248-423b-a2e5-af19c95a17d7">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_650ae54e-c0df-4582-bd4b-ad660a40c301">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b177794f-47f7-42a2-87aa-d9cef0699f36">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c96c2054-16b1-46b6-b941-a6ee47eff787">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5e9bd52f-018a-4e85-b0d2-614090b520bf">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b59ce34f-4d02-4ef3-9f85-5ef3563f64fb">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4590a69c-07fe-40a7-b7c5-26a81ede1ef6">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6a149289-4d69-4d45-bc3e-5d1d3edce47e">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4145c09a-e8af-4386-a53d-e4a30354d537"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a84d216c-9d4e-4db7-bdbf-63efcbf024e7"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2585be7d-1268-4261-b44f-947f7bc0238c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_237876ac-9b6c-42c5-8228-a8738f4fe924"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f0b56db5-a410-4f9c-a5ee-31698b459f0c"/>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>




        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new templates to DICOM PS3.16:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="TID x8005" status="3" xml:id="sect_TID_x8005">
            <title>Immunohistochemistry</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Order:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold"><emphasis role="bold">Non-</emphasis>Significant</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Root:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">No</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="TID x8005" rules="all" xml:id="table_TID_x8005">
                <caption>Immunohistochemistry</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://snomed.info/id/246094008" xl:show="new">(246094008, SCT, "Component investigated")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>MC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>IF Row 2 not present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>D<xref linkend="sect_CID_x8116" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>TEXT</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://snomed.info/id/424361007" xl:show="new">(246094008, SCT, "Component investigated")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>MC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>IF Row 1 not present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C2480" xl:show="new">(C2480, NCIt, "Tracer")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>D<xref linkend="sect_CID_x8117" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>4</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>INCLUDE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><xref linkend="sect_TID_x8006" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>MC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>IFF Row 3 Tracer value is <link linkend="DCM_ddd001" xrefstyle="select: nopage">(ddd001, DCM, "Chromogen")</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>5</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>INCLUDE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><xref linkend="sect_TID_x8007" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>MC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>IFF Row 3 Tracer value is <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0598447" xl:show="new">(C0598447, UMLS, "Fluorophore")</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>6</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://snomed.info/id/424361007" xl:show="new">(424361007, SCT, "Using substance")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1-n</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>7</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>TEXT</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://snomed.info/id/424361007" xl:show="new">(424361007, SCT, "Using substance")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>8</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>DT <link xl:href="http://snomed.info/id/703857004" xl:show="new">(703857004, SCT, "Staining technique")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>D<xref linkend="sect_CID_8130" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>9</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>TEXT</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>DT <link xl:href="http://snomed.info/id/703857004" xl:show="new">(703857004, SCT, "Staining technique")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>10</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>TEXT</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C37925" xl:show="new">(C37925, NCIt, "Clone")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>11</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>TEXT</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0947322" xl:show="new">(C0947322, UMLS, "Manufacturer Name")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>12</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>TEXT</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link linkend="DCM_111529" xrefstyle="select: nopage">(111529, DCM, "Brand Name")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>13</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>NUMERIC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4281604" xl:show="new">(C4281604, UMLS, "Dilution")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>UNITS = EV (1, UCUM, "No units")</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>14</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>NUMERIC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://snomed.info/id/255592004" xl:show="new">(255592004, SCT, "Exposure Time")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>UNITS = DT (s, UCUM, "s")</para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <para>
                <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>Rows 1, 2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Describes the target of the process. Either a CODE or TEXT or both may be present.</para>
                        </td>
                    </tr>
                </tbody>
            </informaltable>
        </section>
        
<section label="TID x8006" status="3" xml:id="sect_TID_x8006">
            <title>Color Immunohistochemistry</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Order:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold"><emphasis role="bold">Non-</emphasis>Significant</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Root:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">No</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="TID x8006" rules="all" xml:id="table_TID_x8006">
                <caption>Color Immunohistochemistry</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    
                    
                    
                    
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link linkend="DCM_ddd001" xrefstyle="select: nopage">(ddd001, DCM, "Chromogen")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>UC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>IF Row 2 not present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>D<xref linkend="sect_CID_x8118" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>TEXT</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link linkend="DCM_ddd001" xrefstyle="select: nopage">(DCM_ddd001, DCM, "Chromogen")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>UC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>IF Row 1 not present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link linkend="DCM_ddd002" xrefstyle="select: nopage">(ddd002, DCM, "Reporter enzyme")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>UC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>IF Row 4 not present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>D<xref linkend="sect_CID_x8119" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>4</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>TEXT</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link linkend="DCM_ddd002" xrefstyle="select: nopage">(DCM_ddd002, DCM, "Reporter enzyme")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>UC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>IF Row 3 not present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
            <para>
                <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>Rows 1, 2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Either a CODE or TEXT or both may be present.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>Rows 3, 4</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Either a CODE or TEXT or both may be present.</para>
                        </td>
                    </tr>
                </tbody>
            </informaltable>
        </section>
        
        <section label="TID x8007" status="3" xml:id="sect_TID_x8007">
            <title>Fluorescence Immunohistochemistry</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Order:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold"><emphasis role="bold">Non-</emphasis>Significant</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Root:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">No</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="TID x8007" rules="all" xml:id="table_TID_x8007">
                <caption>Fluorescence Immunohistochemistry</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0598447" xl:show="new">(C0598447, UMLS, "Fluorophore")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>UC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>IF Row 1 not present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>D<xref linkend="sect_CID_x8129" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>TEXT</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>EV <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0598447" xl:show="new">(C0598447, UMLS, "Fluorophore")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>UC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>IF Row 2 not present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
            <para>
                <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>Rows 1, 2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Either a CODE or TEXT or both may be present.</para>
                        </td>
                    </tr>
                </tbody>
            </informaltable>
        </section>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new context groups to DICOM PS3.16:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="CID x8116" status="3" xml:id="sect_CID_x8116">
            <title>Specimen Components Investigated</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_x8116.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_x8116.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_x8116.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/uuux8116.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">uuux8116</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID x8116" rules="all" xml:id="table_CID_x8116">
                <caption>Specimen Components Investigated</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/23307004" xl:show="new">23307004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Estrogen receptor</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/23307004" xl:show="new">F-B8520</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0034804" xl:show="new">C0034804</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/61078009" xl:show="new">61078009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Progesterone receptor</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/61078009" xl:show="new">F-B8550</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0034833" xl:show="new">C0034833</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/44368005" xl:show="new">44368005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Oncogene protein HER-2/neu</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/44368005" xl:show="new">F-E3260</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0069515" xl:show="new">C0069515</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C17675" xl:show="new">C17675</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>KI-67 Antigen</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0208804" xl:show="new">C0208804</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C94697" xl:show="new">C94697</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>PDCD1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0135710" xl:show="new">C0135710</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>UMLS</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2744928" xl:show="new">C2744928</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Adenine-Thymine</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2744928" xl:show="new">C2744928</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID x8117" status="3" xml:id="sect_CID_x8117">
            <title>Immunohistochemistry Tracer Type</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_x8117.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_x8117.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_x8117.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/uuux8117.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">uuux8117</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID x8117" rules="all" xml:id="table_CID_x8117">
                <caption>Immunohistochemistry Tracer Type</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link linkend="DCM_ddd001" xrefstyle="select: nopage">ddd001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Chromogen</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>UMLS</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0598447" xl:show="new">C0598447</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Fluorophore</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0598447" xl:show="new">C0598447</link>
                            </para>
                        </td>
                    </tr>
                    
                    
                </tbody>
            </table>
        </section>
        
        <section label="CID x8118" status="3" xml:id="sect_CID_x8118">
            <title>Chromogens for Immunohistochemistry</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_x8118.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_x8118.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_x8118.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/uuux8118.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">uuux8118</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID x8118" rules="all" xml:id="table_CID_x8118">
                <caption>Chromogens for Immunohistochemistry</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>PUBCHEM_CID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://pubchem.ncbi.nlm.nih.gov/compound/8588" xl:show="new">8588</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Aminoethyl carbazole</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>PUBCHEM_CID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://pubchem.ncbi.nlm.nih.gov/compound/7071" xl:show="new">7071</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Diaminobenzidine</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>PUBCHEM_CID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://pubchem.ncbi.nlm.nih.gov/compound/41206" xl:show="new">41206</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Tetramethylbenzidine</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>PUBCHEM_CID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://pubchem.ncbi.nlm.nih.gov/compound/11787" xl:show="new">11787</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Chloronaphthol</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    
                 </tbody>
            </table>
        </section>
        
        <section label="CID x8119" status="3" xml:id="sect_CID_x8119">
            <title>Reporter Enzymes for Immunohistochemistry</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_x8119.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_x8119.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_x8119.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/uuux8119.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">uuux8119</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID x8119" rules="all" xml:id="table_CID_x8119">
                <caption>Reporter Enzymes for Immunohistochemistry</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/64652000" xl:show="new">64652000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Horseradish peroxidase</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/64652000" xl:show="new">C-30781</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0019941" xl:show="new">C0019941</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/57056007" xl:show="new">57056007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Alkaline phosphatase</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/57056007" xl:show="new">F-6A2F8</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0002059" xl:show="new">C0002059</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID x8129" status="3" xml:id="sect_CID_x8129">
            <title>Fluorophores for Immunohistochemistry</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_x8129.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_x8129.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_x8129.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/uuux8129.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">uuux8129</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID x8129" rules="all" xml:id="table_CID_x8129">
                <caption>Fluorophores for Immunohistochemistry</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C122989" xl:show="new">C122989</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>NCIt</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>DAPI</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0057142" xl:show="new">C0057142</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0062907" xl:show="new">C0062907</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>UMLS</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Hoechst 33342</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0062907" xl:show="new">C0062907</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Alexa Fluor 488</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4278267" xl:show="new">C4278267</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>UMLS</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Alexa Fluor 555</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4278267" xl:show="new">C4278267</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C3489916" xl:show="new">C3489916</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>UMLS</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Alexa Fluor 647</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C3489916" xl:show="new">C3489916</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
         <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="CID 8111" status="3" xml:id="sect_CID_8111">
            <title>Specimen Preparation Procedure</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_462740b7-c4d6-4dfa-ba8d-263c63e207b0">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8111.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_8111.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_8111.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1049.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ee9ee9ef-a2b4-423e-89de-1afd8073f1f4">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5c093f74-bf87-4b25-9deb-1a2c6d1c0462">
                            <emphasis role="bold"><emphasis role="strikethrough">20080626</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6d43f1b5-22c6-4eeb-8f72-2ae179973d83">
                            <emphasis role="bold">1.2.840.10008.6.1.1049</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8111" rules="all" xml:id="table_CID_8111">
                <caption>Specimen Preparation Procedure</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fcd31b0a-c3b4-4120-b0cf-6fa21f1dc167">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9a05652e-2dfa-482a-8086-a7165cab6438">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_134c21c3-fd9d-4d5e-9098-4c75e7fa6a57">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_327a3012-2154-4027-a124-8ce59f8d5446">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_68a837b3-3c1f-4636-b96e-9f04d05b75ea">UMLS Concept Unique ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_237ffa2d-62ca-4163-9060-26a959bd0a08">HL7 v3 ActClass equivalent</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7b07dc3-d3e3-4c97-a5da-72f27cb0f288">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59074903-67a3-438e-ade2-5fae8e280ad8">
                                <link xl:href="http://snomed.info/id/17636008" xl:show="new">17636008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_94ed8a00-2b83-4745-80f8-cda22a5360c8">Specimen collection</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9885c69b-c3cc-49aa-bc46-150e41d79e6f">
                                <link xl:href="http://snomed.info/id/17636008" xl:show="new">P3-02000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e6c0d16-8ddd-4f0f-a540-c16e25dd5204">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0200345" xl:show="new">C0200345</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ac5a1c0-e4d5-4c2f-9f09-22b8d305fb3a">SPECCOLLECT</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_51ccbb1d-9c15-4db3-8fcc-741c5801ff2a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4dfa0632-58e3-4706-b4b1-e3eeacaab5d3">
                                <link xl:href="http://snomed.info/id/428995007" xl:show="new">428995007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7456adc5-17ff-4ddb-9629-2b4484ebe947">Specimen receiving</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f1d4201-99c9-4def-aba5-caa12090c3bd">
                                <link xl:href="http://snomed.info/id/428995007" xl:show="new">P3-05013</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_65c315f1-1587-4c4e-85ee-9b9d34693b99">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1997702" xl:show="new">C1997702</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b34e38d7-22fc-4b68-b79a-fdaf92d9a4ce">CONTREG</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99179c25-70a0-4494-9ec4-4eee1450fa0e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_75b89348-2486-45c9-aeb6-5d1aab28aea9">
                                <link xl:href="http://snomed.info/id/433465004" xl:show="new">433465004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_09e09197-c912-4d86-bbe2-e122ac11e8ae">Sampling of tissue specimen</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_811555c6-b0fa-40b7-bff0-4b9b969865b6">
                                <link xl:href="http://snomed.info/id/433465004" xl:show="new">P3-4000A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3f9c0cd-1a35-48e0-8a9b-cb7476c4b76b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2316400" xl:show="new">C2316400</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e458592-85dd-4828-9348-164ba4dd2715">PROC</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_52848ead-c7ba-459e-b4bd-4e0a74c82018">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb53807e-989f-44fe-8092-0e90ba8dfdd5">
                                <link xl:href="http://snomed.info/id/127790008" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">127790008</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/127790008" xl:show="new"><emphasis role="bold"><emphasis role="underline">703857004</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6f585110-c118-4bd6-b584-fe952911d6de">Staining</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_159d42a2-64d2-4605-8c0b-1f0c6c8b408c">
                                <link xl:href="http://snomed.info/id/127790008" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">P3-00003</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/127790008" xl:show="new"><emphasis role="bold"><emphasis role="underline">R-FBDF9</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_51c8aa52-818c-4d8d-b7df-10597d4c916b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0487602" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0487602</emphasis></emphasis></link>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C3839348" xl:show="new"><emphasis role="bold"><emphasis role="underline">C3839348</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_489415c7-2130-43d1-8ee1-5931b6d0ddef">SPCTRT</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50ada286-6f31-486f-bcda-031a9b65f565">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af693443-0a9c-4b85-8d7d-abf84aa907ef">
                                <link xl:href="http://snomed.info/id/9265001" xl:show="new">9265001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7e34759b-4e9c-4074-860e-8fbdb7ff640e">Specimen processing</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a60d282a-bef9-4201-ae44-a1a491cada16">
                                <link xl:href="http://snomed.info/id/9265001" xl:show="new">P3-05000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3fcb2e04-4d79-4760-898b-e3bd593c0df2">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0037793" xl:show="new">C0037793</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9cd2331-6aa1-49fa-933c-b848cd3d3152">SPCTRT</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a528e465-c05b-47db-aaed-aeea144bcb5e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc892e19-9caa-40da-9ec6-708d9d19988f">
                                <link linkend="DCM_111729" xrefstyle="select: nopage">111729</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_649b7c6b-165b-4ef3-9495-f5a143391f70">Specimen storage</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f2b4375-3573-4d6e-9539-d7cdaca52f37"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f315cb9-ace0-4a5e-b50b-3ade1adeb15e"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6ad33b7-864c-4dc3-8861-18e955f59f57">STORE</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/117617002" xl:show="new"><emphasis role="bold"><emphasis role="underline">117617002</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Immunohistochemistry</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/117617002" xl:show="new"><emphasis role="bold"><emphasis role="underline">P3-44150</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0021044" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0021044</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <para><emphasis role="bold"><emphasis role="underline">Previously, <link xl:href="http://snomed.info/id/127790008" xl:show="new">(127790008, SCT, "Staining method (procedure)")</link> was used with the meaning "Staining", but has been replaced by <link xl:href="http://snomed.info/id/703857004" xl:show="new">(703857004, SCT, "Staining technique (qualifier value)")</link>.</emphasis></emphasis></para>
            </note>
        </section>
        
        <section label="CID 8112" status="3" xml:id="sect_CID_8112">
            <title>Specimen Stains</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_fef963e7-d2c4-44b0-93e0-98cff03bba01">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8112.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_8112.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_8112.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1050.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_89801f74-bb90-4152-990a-604b6827a96d">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f7a34b2d-6bd3-4a23-8a7e-79e48444d9a8">
                            <emphasis role="bold"><emphasis role="strikethrough">20190817</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5d221105-c38e-42bd-9ca7-7fdb3a195b41">
                            <emphasis role="bold">1.2.840.10008.6.1.1050</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8112" rules="all" xml:id="table_CID_8112">
                <caption>Specimen Stains</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a025b12-a914-446c-90c3-a991ec9ecda7">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80234dd8-cd42-4cc9-8031-458eb03f1258">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a1983bf7-9962-4cc2-ba99-79222f171cc3">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66894a6d-4307-4e73-bd35-b33bccebe377">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f68c57ec-fc09-4d7c-adef-7087c4fa6db2">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c62c654b-fdbe-4e64-aaa7-c6f7a646137e"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12e8c7b4-4972-4853-b06f-84b30dac18b1">
                                <link xl:href="http://snomed.info/id/406976001" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">406976001</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_380b1bae-8e8a-4428-bd4a-6f5880e2d9b2"><emphasis role="bold"><emphasis role="strikethrough">acid fast stain</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_511155c6-94bb-45fc-be4d-1c4d41f398ce">
                                <link xl:href="http://snomed.info/id/406976001" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C-22860</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_26a28e50-6fdf-4968-b983-a91711ecf4f9">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318720" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C1318720</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3b11ba7-2627-41c1-a906-bfb7307b0788">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff15af4c-9b79-45e3-abaa-61141dcefdfe">
                                <link xl:href="http://snomed.info/id/255792001" xl:show="new">255792001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_73fc1c5f-ab6e-4f57-a87a-f91760d08462">acid phosphatase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d086bded-014a-443a-a03d-ff0d77e1d63e">
                                <link xl:href="http://snomed.info/id/255792001" xl:show="new">C-2280A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff836701-eeb4-4b46-9c5c-5ec4b982ebcb">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440036" xl:show="new">C0440036</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e033d71-b330-49db-9b20-b1719e5802d9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ce06261e-0d8a-4d32-a075-41abcc295c07">
                                <link xl:href="http://snomed.info/id/255793006" xl:show="new">255793006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bd306f79-3977-4a05-b8df-a7807b28a0a2">Albert's stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a591d04b-c508-4c39-9cfb-192c431872d8">
                                <link xl:href="http://snomed.info/id/255793006" xl:show="new">C-2280B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a560b77f-d757-4f8a-9e0e-1f6f6d3d75df">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440037" xl:show="new">C0440037</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2059c8b7-8fcb-4bc9-833a-a8f9cbb62363">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9189d018-c7d5-4709-a284-346125888aea">
                                <link xl:href="http://snomed.info/id/4656000" xl:show="new">4656000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fd7b1169-f5c0-4cff-a5f0-676c98bae16c">alcian blue 8GX stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_67c9e37e-2923-4351-8c22-5acbafaed155">
                                <link xl:href="http://snomed.info/id/4656000" xl:show="new">C-22963</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_33a2ba81-6b30-4bb1-b960-a614f12227f0">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0001933" xl:show="new">C0001933</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e660634a-fdd4-482a-94a3-2f3b3b512394">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f7c75f8-92bb-4c43-a2f1-5920f7b5db19">
                                <link xl:href="http://snomed.info/id/47995002" xl:show="new">47995002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_df93a33e-f156-4cf3-ae6d-67546dda8194">alcohol soluble nigrosine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e17748ce-fb66-4fdd-87ed-61d27f74e7fe">
                                <link xl:href="http://snomed.info/id/47995002" xl:show="new">C-22932</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3f332eb-153f-46cd-8cf8-88552bf8096d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303908" xl:show="new">C0303908</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_68cbd883-d3be-4228-9bf6-03f8306bf86e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c63979e-37e5-4279-b2f9-792a1f3443fc">
                                <link xl:href="http://snomed.info/id/406981005" xl:show="new">406981005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3bca47fa-a90d-48a7-bc1e-a393a989e3f0">aldehyde fuchsin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06e8e175-900c-4617-b6ab-26858d588dcb">
                                <link xl:href="http://snomed.info/id/406981005" xl:show="new">C-2286D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f333d323-558a-49e8-b54d-ab1db852fa9c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0491984" xl:show="new">C0491984</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d9196d9-9e0a-43d2-bf39-5bc2bbf2fbba">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cac0c7b-029a-404e-a292-a05c2851103f">
                                <link xl:href="http://snomed.info/id/54432009" xl:show="new">54432009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7f243a95-fa55-4329-9abe-b19908815688">alizarin blue S stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57050316-0510-4101-9847-fe7248f9853f">
                                <link xl:href="http://snomed.info/id/54432009" xl:show="new">C-22961</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc4be4dd-499d-443d-a66f-c74ab9ee1e6f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303917" xl:show="new">C0303917</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b636ebad-7022-4c33-bc25-43113c56eb18">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_661e98ce-fda1-48c2-a25a-9023e9553cf5">
                                <link xl:href="http://snomed.info/id/21951008" xl:show="new">21951008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9b3bbd11-496b-4602-b277-289e23675cf6">alizarin cyanine green stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91fccf9e-fdfc-4f7b-929b-df0d9177caaf">
                                <link xl:href="http://snomed.info/id/21951008" xl:show="new">C-22959</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_878a209c-2816-46a1-bb4b-be98e747b90f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303916" xl:show="new">C0303916</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dced6d74-cfbb-422b-8f66-5ed82c8e95af">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87becee3-e560-4bae-8f7a-c085739ae01d">
                                <link xl:href="http://snomed.info/id/65580004" xl:show="new">65580004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1437ef31-18bf-4c30-9614-6619875c88b9">alizarin red S stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ee4eebe-d381-474d-a811-dd459755a36a">
                                <link xl:href="http://snomed.info/id/65580004" xl:show="new">C-22953</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_95c9b92c-dbc3-4388-adce-c964861f7a9e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0051165" xl:show="new">C0051165</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8bc76649-d11f-4cfe-afa7-f4d3ae760fa7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_146d6717-60e0-4a96-91c0-ca65ac385f1b">
                                <link xl:href="http://snomed.info/id/27016007" xl:show="new">27016007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_88867c15-3a81-434f-b288-94007b0f9cb5">alizarin yellow GG stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_32b3bf70-dffa-4219-b064-89b53f20f324">
                                <link xl:href="http://snomed.info/id/27016007" xl:show="new">C-22813</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f34f67a-6261-4cb1-bb06-e2a96b41dd43">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303861" xl:show="new">C0303861</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9951a912-eea6-4de9-81b7-7ea5cb65df8a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6aa2c260-caa0-4b9a-b164-0c48e0bf08f7">
                                <link xl:href="http://snomed.info/id/28622002" xl:show="new">28622002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bae5dd16-e46c-4d02-a0ef-d83dc2e4dcd9">alizarin yellow R stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef166663-4fc1-46eb-ae05-129d389f63ad">
                                <link xl:href="http://snomed.info/id/28622002" xl:show="new">C-22814</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2668be9e-a702-4526-9440-2988552af8ff">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0619792" xl:show="new">C0619792</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2519194d-5be0-4777-bf8e-bfc9349494d9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7be2f155-0be7-4b12-a033-d2b54a8667b6">
                                <link xl:href="http://snomed.info/id/406971006" xl:show="new">406971006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a432798d-024a-4cd8-99aa-7d38009d4965">alkaline phosphatase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f359c018-afe3-489e-a8b4-33dfb236500b">
                                <link xl:href="http://snomed.info/id/406971006" xl:show="new">C-2285B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f83b7f6-e883-49ad-8d6c-63c93b5476aa">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318717" xl:show="new">C1318717</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7399424-11b3-4b76-9c18-702e1e1bdfa7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38adc7b0-073d-48d7-b087-15cfd9346e9b">
                                <link xl:href="http://snomed.info/id/406990003" xl:show="new">406990003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9433e191-1c51-482c-a60c-937d0d305572">aniline blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c5906986-2a29-449f-8ac5-d4a6ecad338d">
                                <link xl:href="http://snomed.info/id/406990003" xl:show="new">C-2287E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_74c0aafc-a1bb-4f91-a52f-47dd309b69a7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1321796" xl:show="new">C1321796</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a3d077a-3330-489a-9dac-e526e4715c50">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b4c887db-d676-44ff-a41a-2aa04470739b">
                                <link xl:href="http://snomed.info/id/255794000" xl:show="new">255794000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_de83890b-79bf-49e4-ad3a-a4bc77b84151">auramine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_13bc2b89-6c45-481e-a15e-60cc860a8539">
                                <link xl:href="http://snomed.info/id/255794000" xl:show="new">C-2280C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6eed8419-2e13-4c6e-a18c-5eb866209d1a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440038" xl:show="new">C0440038</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fb086f59-56e0-4038-a0cb-694b3944c005">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0fd8a12d-67f5-44b9-90c3-9e135eff9de8">
                                <link xl:href="http://snomed.info/id/85066006" xl:show="new">85066006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5a595ff3-6cf4-4406-8783-efabee6d6d99">azo black stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f5277b3d-ed4c-4aab-ba9d-04b984adb079">
                                <link xl:href="http://snomed.info/id/85066006" xl:show="new">C-22873</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e856c00e-265b-401c-860d-35ba06105722">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0058437" xl:show="new">C0058437</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92b5a5f8-fd25-44a1-be46-d89621885e77">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cad9b49a-4d82-4c61-b072-f0b2b6062b86">
                                <link xl:href="http://snomed.info/id/76048000" xl:show="new">76048000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ffb372dc-10b8-44fa-bb75-037cec437cd0">azocarmine G (GX) stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53342282-8a48-4a40-8413-14792cf70c65">
                                <link xl:href="http://snomed.info/id/76048000" xl:show="new">C-22929</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da0827d8-867e-4c8e-86ea-bb5126c05dfe">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303907" xl:show="new">C0303907</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d5c5202c-f79b-4a22-9905-d668ddbb7d05">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76705f27-d135-49f7-91f9-7596bce65ff1">
                                <link xl:href="http://snomed.info/id/35609001" xl:show="new">35609001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ae0406dd-5ab7-4f97-9a98-fee37f0e66b6">azophloxin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc65cde5-31f1-4aec-8c0b-4820f6cf473c">
                                <link xl:href="http://snomed.info/id/35609001" xl:show="new">C-22842</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_633f9757-276a-4c6a-9fdb-edd589b3bab0">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0073022" xl:show="new">C0073022</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a6164824-ef52-45f6-ad50-896981444d57">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f54c550-0fdd-4b8c-86d3-5bdf13f3286f">
                                <link xl:href="http://snomed.info/id/2159007" xl:show="new">2159007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ac311f3c-2ab2-4a0b-a068-f36077d1041d">azorubin S stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3251ddd-f152-4012-831a-b9f49390584e">
                                <link xl:href="http://snomed.info/id/2159007" xl:show="new">C-22831</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_48e6b9c6-03ad-40cb-9a47-e92b7d5ae5df">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0002406" xl:show="new">C0002406</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cbff2b8d-19c0-47df-8330-a6133f08a9f1">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19e3b686-9dd0-435f-85b9-86f6bb2a291e">
                                <link xl:href="http://snomed.info/id/16836001" xl:show="new">16836001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_30100ecc-3a0b-4fc4-a43c-060c09d96271">azure A stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20f4153a-a4e5-4121-9d85-92db754a0f8b">
                                <link xl:href="http://snomed.info/id/16836001" xl:show="new">C-22945</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fadc17f0-2440-4a20-b912-62ae48c86d64">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0052826" xl:show="new">C0052826</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9d0bdbf-d72f-4840-b0ea-a04e87ab4ffa">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42058ba3-11b0-4efe-b497-15cc5701bd7e">
                                <link xl:href="http://snomed.info/id/8926000" xl:show="new">8926000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bd3ea2d9-818c-4fe0-82a0-714c4a666653">azure B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fec2610c-f300-4813-8143-83754ddc127f">
                                <link xl:href="http://snomed.info/id/8926000" xl:show="new">C-22946</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76524a60-69d0-488f-9781-00f0004bf3ca">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0052827" xl:show="new">C0052827</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19021ae0-7423-45b1-9e10-7005ea520299">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dbbc0a4b-7a52-4ab0-b3af-c10cfdf1d440">
                                <link xl:href="http://snomed.info/id/11069001" xl:show="new">11069001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0ec86880-673c-4fd7-9e21-cb736d6b8c42">azure C stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99aab696-b86b-4e24-9cf0-e740893acbaf">
                                <link xl:href="http://snomed.info/id/11069001" xl:show="new">C-22944</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b61b7828-9c2e-4fbf-be99-9350ea12e94f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0052828" xl:show="new">C0052828</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6c19672a-6519-4b59-b551-f25a16837b95">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_16285686-caf7-4ee5-a7e0-b88e14750b46">
                                <link xl:href="http://snomed.info/id/406982003" xl:show="new">406982003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_63df535b-4226-4aeb-a821-2514a25dcf40">bauer's chromic acid leucofuchsin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89235fac-0724-40ed-9511-cae85dbacdf0">
                                <link xl:href="http://snomed.info/id/406982003" xl:show="new">C-2286E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3fd1ebe-7cd4-45fd-b2dd-56f94fb443ef">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318723" xl:show="new">C1318723</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_478cc6a3-afc5-4617-af22-8790e5b842d4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e98b58d-0f2f-4531-bf6f-86a521fbaa7c">
                                <link xl:href="http://snomed.info/id/27844007" xl:show="new">27844007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_40488736-fdc4-4b82-8a20-2d62a947a954">benzo fast scarlet stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bcf3915d-c78f-4ab5-9d93-bf82a7d914b9">
                                <link xl:href="http://snomed.info/id/27844007" xl:show="new">C-22872</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1b931099-1c9f-4e4d-906d-e66ab411b137">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303882" xl:show="new">C0303882</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_545899be-673b-4d13-9a0c-8e441a351606">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ee349f33-2238-4170-ab01-b4868d86ab28">
                                <link xl:href="http://snomed.info/id/255795004" xl:show="new">255795004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dd424fd0-8990-4ab5-819c-0c7dbbcf6deb">beta-glucuronidase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ae8a2cb-b5b2-42d5-9c63-a7cf70bb41f1">
                                <link xl:href="http://snomed.info/id/255795004" xl:show="new">C-2280D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6880bd63-ec65-4b43-84f4-12c5c7768c61">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440039" xl:show="new">C0440039</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54c22d23-02f2-4b50-b498-99b8b52e4840">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d39afce8-4c38-4279-a0f8-02ad4b72aaa4">
                                <link xl:href="http://snomed.info/id/76605005" xl:show="new">76605005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8239b8d5-403d-453b-afae-1e8107949a60">biebrich scarlet stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8705bfea-bc23-4757-b663-cc5454d7e247">
                                <link xl:href="http://snomed.info/id/76605005" xl:show="new">C-22866</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ef20156-e717-4d6f-a776-47f25fe99724">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303878" xl:show="new">C0303878</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b7ef4fe7-16fa-4ea8-94a2-ad3454111982">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54cbba18-b29d-4d57-af1d-a2841e9e9d00">
                                <link xl:href="http://snomed.info/id/44488008" xl:show="new">44488008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1adfd957-c7c0-4caa-bcf0-ef1f79636263">bismark brown R stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6cbe8c97-783a-4390-a34e-65e121c0e636">
                                <link xl:href="http://snomed.info/id/44488008" xl:show="new">C-22849</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f9550390-15a7-4ae6-9e4c-a9124b24f7bd">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303872" xl:show="new">C0303872</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21f3f776-72a6-4fac-b9c6-a9d1582e3652">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_118bff7d-369a-4cad-9ebb-e11c5e25ccb2">
                                <link xl:href="http://snomed.info/id/85190005" xl:show="new">85190005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_df1e7e75-cf7a-4fe4-bc87-806401de41d7">bismark brown Y stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04c22e1c-7916-488f-9535-38459b85d6bf">
                                <link xl:href="http://snomed.info/id/85190005" xl:show="new">C-22848</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_962d68e1-6ab0-437f-9170-561b849be96a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303871" xl:show="new">C0303871</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a424fc09-3e09-40f0-9447-a9d30f47bf75">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f86f049f-b9f8-436e-a91f-48214d16997a">
                                <link xl:href="http://snomed.info/id/1346008" xl:show="new">1346008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d0e4fa7e-9ccb-49c1-97e7-94c5f304e727">blue shade eosin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f181d7a-109b-42d2-9563-e879186fb4bd">
                                <link xl:href="http://snomed.info/id/1346008" xl:show="new">C-22921</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85502215-f77c-4c8a-95d9-dc348bed32d3">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303904" xl:show="new">C0303904</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87b3d08e-1e65-4d67-8446-e40d0d5d64a3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0422fa7-cbc8-43ba-9041-590c79baf27f">
                                <link xl:href="http://snomed.info/id/41750006" xl:show="new">41750006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_72430f97-a42b-4c95-830d-961d1a5ffad0">brazilin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f40c908e-e7c4-433c-b99f-db28b48709f6">
                                <link xl:href="http://snomed.info/id/41750006" xl:show="new">C-22965</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62fa9775-b1c8-4978-9ada-558fa43a3545">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0054031" xl:show="new">C0054031</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a649280d-eee8-4f7b-8ddd-0212ff4f76ce">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3b3a876-041e-402c-85aa-2cdc135a6d65">
                                <link xl:href="http://snomed.info/id/8342001" xl:show="new">8342001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_88f81ae9-aabd-4ab0-b728-49fed04dfe92">brilliant cresyl blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3dcc6cd7-2cd6-4c52-88e8-3ad01cf229d1">
                                <link xl:href="http://snomed.info/id/8342001" xl:show="new">C-22934</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cdc369ba-5b6f-4926-bce4-fbfb754a924b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0054052" xl:show="new">C0054052</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7c6a9094-b896-4142-bf12-9265703f2a76">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1003de0-0333-47c4-bdc9-35b07f0bac39">
                                <link xl:href="http://snomed.info/id/86541009" xl:show="new">86541009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ba524336-4a5a-41ef-8ab1-1a29881d03a7">brilliant crocein stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_33a34bea-0614-42c9-9bb1-8d27a8887ed4">
                                <link xl:href="http://snomed.info/id/86541009" xl:show="new">C-22869</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b15e418f-d7f1-4da3-b0ad-3d1ade125a3d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303880" xl:show="new">C0303880</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9627cd0f-6955-4308-933c-07be13809acc">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b789dd09-729e-413e-ab15-0919c5e17b85">
                                <link xl:href="http://snomed.info/id/8429000" xl:show="new">8429000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7658819b-f069-46ca-b448-9eadc863367c">brilliant orange stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8eda0a92-e6ed-4d57-ac3b-8b51454edd7f">
                                <link xl:href="http://snomed.info/id/8429000" xl:show="new">C-22865</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e8b1f1d0-0e7e-402d-a73c-4d59a1462125">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303877" xl:show="new">C0303877</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_48e52799-2c0f-4285-894e-938ab9c59ce6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4afe3b42-27d5-4075-b55c-6047e1b93b35">
                                <link xl:href="http://snomed.info/id/57753006" xl:show="new">57753006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c1d81e43-441d-4f3c-bd44-fccd825d1bc9">brilliant yellow stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3c15912-1ec5-4342-b40e-94b2d9d3151e">
                                <link xl:href="http://snomed.info/id/57753006" xl:show="new">C-22857</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_899f9884-74cf-4a96-87b6-fc0a5147e57e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0058441" xl:show="new">C0058441</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_313d238d-dfc0-47a9-8034-68014d1b724e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_285524e4-4e36-4b35-8cb9-ac0361ed634c">
                                <link xl:href="http://snomed.info/id/406955006" xl:show="new">406955006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8f032c1c-e8f4-4688-91d2-54f652c9b993">butyrate esterase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_827eef73-e582-41ce-88e7-4286008596e3">
                                <link xl:href="http://snomed.info/id/406955006" xl:show="new">C-2283C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1fd8b9ec-3b2a-4df2-916b-6d7a01fbcabd">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1321545" xl:show="new">C1321545</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eaa9adc2-9113-4939-aa74-ec29f88bcbbd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d432770f-bc27-4d9f-9827-262c47eca18d">
                                <link xl:href="http://snomed.info/id/764166003" xl:show="new">764166003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a93033fc-1ec5-4d01-96bd-89371b40aa25">carbol fuchsin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6bbaf83f-5b19-41c0-9793-aa4d57963cf8"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0f78153-5c23-498e-9999-dd799e196f9a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0054697" xl:show="new">C0054697</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5bafaf8-e0b9-4b54-9692-2e8303dc381a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80837aba-2ebe-48fe-8e1c-5f359c9a9742">
                                <link xl:href="http://snomed.info/id/73892005" xl:show="new">73892005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_454e3265-d59a-47c1-8bbb-c849f282a75c">carmine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78684c90-e84a-4090-994c-114af24627ce">
                                <link xl:href="http://snomed.info/id/73892005" xl:show="new">C-22971</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_958e33ae-db0b-4f94-93ef-e196cefdb1f5">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007250" xl:show="new">C0007250</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad7ed414-cbf3-4e4d-a756-e872c2befd4c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fd2e8a21-dd4e-44c9-9293-19b8d386e99a">
                                <link xl:href="http://snomed.info/id/432003" xl:show="new">432003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0523602f-e3cd-4b49-bcf4-b03be79736be">carminic acid stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d233bc09-6d35-434a-b8f4-dace6277423a">
                                <link xl:href="http://snomed.info/id/432003" xl:show="new">C-22972</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f1e0cf3-71c9-40cf-8690-0e17b4c286f1">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0054801" xl:show="new">C0054801</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5750b5e6-22f7-44cc-bbc6-448ce36a8239">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ccfdb996-8f2f-4caa-9571-54ec95118390">
                                <link xl:href="http://snomed.info/id/37575004" xl:show="new">37575004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e9ea4f52-11e1-4753-9b74-486f5f3fe830">carmoisine A stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_81c5367d-4889-4121-bb06-afa3078113c4">
                                <link xl:href="http://snomed.info/id/37575004" xl:show="new">C-22822</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc37497f-95b7-4bed-8bc5-523b22825596">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0052799" xl:show="new">C0052799</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b8820b7-6f7a-4d9f-835e-560f047e514c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9af18132-2bcd-4cf6-9198-14c48a3c5999">
                                <link xl:href="http://snomed.info/id/38707008" xl:show="new">38707008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_146179f9-2c39-4b67-ac7f-b84418c7b8af">celestine blue B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1fc400a-c12f-4969-9c37-d507030519f3">
                                <link xl:href="http://snomed.info/id/38707008" xl:show="new">C-22936</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_68a1c3b1-bc2c-440b-852c-3305ea2d2fae">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0055019" xl:show="new">C0055019</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_731517c3-ac1b-4044-a409-2248988ae5ea">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ee88e53-dff0-4e54-855c-1acff4ee09e8">
                                <link xl:href="http://snomed.info/id/255796003" xl:show="new">255796003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_da7e4f93-f5c0-41e6-85fc-3bb868c310d5">chloroacetate esterase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa5e7d0a-7089-46d1-b0e3-ccc04b44bc6d">
                                <link xl:href="http://snomed.info/id/255796003" xl:show="new">C-2280E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84b33c3b-4cca-4626-b1c4-5e78beed4392">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440040" xl:show="new">C0440040</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0608efc4-89c5-47bb-b43e-a721a4d0663d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3018e992-63ef-4229-95fd-f77f2a8d5389">
                                <link xl:href="http://snomed.info/id/406986000" xl:show="new">406986000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_47e9710b-da86-42ee-96c9-87f7070c41d5">chromic acid stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a078cfe3-92ed-4142-95fd-9610fbb37199">
                                <link xl:href="http://snomed.info/id/406986000" xl:show="new">C-2287B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2786fbf-f4d1-4ca6-a2d7-f9541e4a3407">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1321562" xl:show="new">C1321562</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66e3ce4f-fcde-4b0f-988b-4ef6ca3cea58">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8109f740-401a-4372-9f20-1b522b2dddd2">
                                <link xl:href="http://snomed.info/id/85981002" xl:show="new">85981002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8ea56428-ef44-4b74-9cde-8077ef95eca6">chromotrope 2R stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2093dc3c-6162-4f39-9fa7-bec7e903b3e2">
                                <link xl:href="http://snomed.info/id/85981002" xl:show="new">C-22838</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_25adbb80-b4d9-4407-9aa9-481fdfe65871">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0109683" xl:show="new">C0109683</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b7f5f621-93ab-471b-ac57-d4be419c3cdb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82fda8df-73a4-4241-b2c7-cfa5f427628b">
                                <link xl:href="http://snomed.info/id/10247008" xl:show="new">10247008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_75cadace-3351-4360-a082-490f08cda1b2">chrysoidine R stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_323b26c5-6d06-44dc-97f6-3468bf53af6a">
                                <link xl:href="http://snomed.info/id/10247008" xl:show="new">C-22806</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a6bab1de-5368-4364-8937-b320af106565">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0109694" xl:show="new">C0109694</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2b5e36f-6136-4ecc-921b-faf0dfb402b5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_539bc4aa-9123-41b0-a2a9-19e1c01b6b58">
                                <link xl:href="http://snomed.info/id/16943008" xl:show="new">16943008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e6a43839-4448-4423-b8e4-64f63bce9e5a">chrysoidine Y stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e31ae41-6b34-4a36-bff2-db498e726371">
                                <link xl:href="http://snomed.info/id/16943008" xl:show="new">C-22805</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58456a8b-2b58-4b27-a9d5-8ae5dfc363dd">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0055663" xl:show="new">C0055663</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b32aede0-757c-408f-b41a-97895ac5b703">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e009e20-3f83-4d8e-a242-e4d16b2b002c">
                                <link xl:href="http://snomed.info/id/91606004" xl:show="new">91606004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c0a39517-2de8-4544-ad1e-a3ad2849ee2d">cochineal stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e46259f-7aed-4f41-a252-b188d4bd85b1">
                                <link xl:href="http://snomed.info/id/91606004" xl:show="new">C-22973</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a0ea4ea5-e2e8-48e4-8ac9-16912671c51f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0110382" xl:show="new">C0110382</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e03cb580-ccd8-4caa-8600-318377f18df8">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c831672-772e-4ab2-a594-18b630eab633">
                                <link xl:href="http://snomed.info/id/406952009" xl:show="new">406952009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b6634eb6-551e-43a5-aa03-b76805b12842">colloidal iron stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e803349b-4a9c-44a1-96f7-f8b8de15c040">
                                <link xl:href="http://snomed.info/id/406952009" xl:show="new">C-22837</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f098852-4a8e-4d4a-886f-1357c45e0584">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318877" xl:show="new">C1318877</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5625da4b-98a1-408b-bcf1-befa3ed7cf7e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22d05ab3-cf6f-43f3-a7d4-6bef9a853b2a">
                                <link xl:href="http://snomed.info/id/45106005" xl:show="new">45106005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_68dc6fce-1a20-409e-8311-ae35d6c7dafd">Congo red stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_68721a6d-3d89-4bd6-af6c-66f6401a9a35">
                                <link xl:href="http://snomed.info/id/45106005" xl:show="new">C-22851</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_574aca64-c998-4afc-8686-725883750387">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0009742" xl:show="new">C0009742</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d498dbf3-de3f-4d6f-91ee-c0be32866748">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_abf5a0ef-2b24-46e2-86c0-c6d0601f43f7">
                                <link xl:href="http://snomed.info/id/406960005" xl:show="new">406960005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_58324a82-4fdf-465f-a436-f4a779d15ddd">cresyl echt violet stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c86ec522-0817-4f4d-af60-d5d0781a5d92">
                                <link xl:href="http://snomed.info/id/406960005" xl:show="new">C-22847</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c8d7abc-b61f-434c-81a2-caafd5990559">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318879" xl:show="new">C1318879</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4cb8c971-27f6-4398-a57a-69474763a75e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42982ea5-c621-45d2-b4eb-e364754634d6">
                                <link xl:href="http://snomed.info/id/406959000" xl:show="new">406959000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b9cf2e69-91b5-4204-b954-e2a53b07a3de">cresyl violet stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4567fd78-515f-4762-ba42-055de62e6f35">
                                <link xl:href="http://snomed.info/id/406959000" xl:show="new">C-22840</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ad4c801-ec63-4066-9d31-5892224984ae">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0056484" xl:show="new">C0056484</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a9bfb22-aa84-4d46-89cb-83cacff2a244">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c62cac82-e44d-4467-93c2-9595b6a9931e">
                                <link xl:href="http://snomed.info/id/68459007" xl:show="new">68459007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0b3823c5-898a-4b08-ba92-b4fa5af3befb">crystal ponceau stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d8db96d9-99f7-4bd7-b7d9-378a91b43c35">
                                <link xl:href="http://snomed.info/id/68459007" xl:show="new">C-22833</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f962fd3a-1425-4e2a-93b9-9488eaf97cb6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303867" xl:show="new">C0303867</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4cebfae8-f022-49e2-bfae-f34bf08b8dd8">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b7eccf4f-54d0-4999-8320-ea74f8e27326">
                                <link xl:href="http://snomed.info/id/89028002" xl:show="new">89028002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ad50fc4d-2f2c-4623-ae98-001d79cbd493">curcumin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef78e377-7ec8-41ce-8bfa-a15087e90249">
                                <link xl:href="http://snomed.info/id/89028002" xl:show="new">C-22966</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3093103d-bdab-4fe2-83b3-d10da3c7431a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0010467" xl:show="new">C0010467</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9762d6f6-aaf9-454b-80d8-71e000dcce04">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a47a3b7-86e3-4d39-a7c6-21397b9df3ea">
                                <link xl:href="http://snomed.info/id/72572003" xl:show="new">72572003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cb39dcbe-a2b7-46da-9b62-c79958ad5e9d">diamond black stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c9e5b4a-7c21-4375-9191-b7bcc4de1416">
                                <link xl:href="http://snomed.info/id/72572003" xl:show="new">C-22826</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db3292fc-d192-4d0f-805a-eb1f180fc7ed">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303866" xl:show="new">C0303866</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4602fa3-ba60-49f5-bdbf-f90fa7bdab89">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64ac22c5-c79d-41e0-9738-f699d5caeecc">
                                <link xl:href="http://snomed.info/id/11780008" xl:show="new">11780008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_77a7c7e4-f172-466c-b4dc-3826f23e60e8">durazol red stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e85d24e8-b9b2-49a5-89a4-674a64dcd1e3">
                                <link xl:href="http://snomed.info/id/11780008" xl:show="new">C-22871</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b9b3929-d623-4160-a3fd-b3f401a61e15">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303881" xl:show="new">C0303881</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e79d724-d125-40c0-8e97-7dc54e0c7d5d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3c38b2c-972f-4eed-b80a-54f0cb8a5e0f">
                                <link xl:href="http://snomed.info/id/40076005" xl:show="new">40076005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d8939cf7-c342-42f0-a50d-99b6a205b861">erie garnet stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bfa5d33d-d498-4de6-8c6f-13d268d7d7c8">
                                <link xl:href="http://snomed.info/id/40076005" xl:show="new">C-22852</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b76c9813-4cfd-4cfe-876f-900995091b55">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303873" xl:show="new">C0303873</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09bf5693-b779-4fc7-8420-cf0e32bccd8c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_304bddb9-b1c0-4106-8338-1e20b3fb886b">
                                <link xl:href="http://snomed.info/id/58631000" xl:show="new">58631000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1ce372ea-27a4-4374-87fb-ff5d65c1a3cb">eriochrome blue black SE stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fe66476c-8032-4e61-8df7-91b46a36c3c2">
                                <link xl:href="http://snomed.info/id/58631000" xl:show="new">C-22839</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f26364c3-1131-4494-b160-a2b9d54914bc">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0059526" xl:show="new">C0059526</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56b8735c-fa7d-4c04-842f-b07cb1883309">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0cd10e7-99d5-4c28-81a2-40ac56a31673">
                                <link xl:href="http://snomed.info/id/7434003" xl:show="new">7434003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4b17ce84-80e6-4664-9820-1ecdac00e0b6">erythrosin B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f097d29d-5c66-4edd-b852-859140808796">
                                <link xl:href="http://snomed.info/id/7434003" xl:show="new">C-22924</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_801678df-bce5-4490-825e-9e4f214d929e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0014824" xl:show="new">C0014824</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3ff2a6d2-5c99-427b-ba04-03058695419f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a4b51168-b7cc-432a-bc06-02401a899657">
                                <link xl:href="http://snomed.info/id/5043000" xl:show="new">5043000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_86cb645e-35ce-4e8a-b3e0-53bd1b0e7ff7">erythrosin Y stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8abcbbe-e900-492b-9ac6-6aeb7ad82359">
                                <link xl:href="http://snomed.info/id/5043000" xl:show="new">C-22923</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54d9b17b-fb70-4d36-8831-25087a85ef36">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303905" xl:show="new">C0303905</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92548ee8-6afe-41c4-9728-db2414100e62">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f58d247-2864-4bbb-96dd-3fdfc7d431f1">
                                <link xl:href="http://snomed.info/id/22931006" xl:show="new">22931006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3f1b03b4-4544-492e-b257-4a6d28cff789">Evans blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b522a59c-5a29-4819-8ed7-cff4b633b65d">
                                <link xl:href="http://snomed.info/id/22931006" xl:show="new">C-22854</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0376b44e-342f-463b-84b5-00c4f113f34a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0015205" xl:show="new">C0015205</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91a9792e-a520-441a-8034-d0ba27544b45">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_faf4b1f9-b5eb-4d2f-adfe-8bc710bfd965">
                                <link xl:href="http://snomed.info/id/34700000" xl:show="new">34700000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6282e083-5354-4a43-840b-acd5547d328a">fast blue B salt stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a6579e1-f4f6-4e8e-a6b0-8cd20abba873">
                                <link xl:href="http://snomed.info/id/34700000" xl:show="new">C-22883</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b49078f-fd94-45a3-874c-c477107e1b1d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303888" xl:show="new">C0303888</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ce327234-d3ef-4e9a-8fbe-27430fe5dd6f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_906dae84-4295-4e6c-840d-48219b64fd9f">
                                <link xl:href="http://snomed.info/id/91295002" xl:show="new">91295002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2d167fd6-e805-406b-8852-c5e486d79f39">fast blue BB salt stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b08c8df-156a-4467-a399-5f5d94047afa">
                                <link xl:href="http://snomed.info/id/91295002" xl:show="new">C-22881</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9206a9d4-4663-4299-a1a4-282833657721">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0060085" xl:show="new">C0060085</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_432e9341-b92c-4163-a1fc-92f5d194d26b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d811e7a-4259-486d-92dd-a20e88fe688e">
                                <link xl:href="http://snomed.info/id/64112001" xl:show="new">64112001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ec2a6a22-ba19-4b2d-af23-9a2c64631d63">fast blue RR salt stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5521b73a-438a-4be2-b008-e5aaa29c0276">
                                <link xl:href="http://snomed.info/id/64112001" xl:show="new">C-22878</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62fdc6fe-3afb-4c36-8e05-9219f55f4340">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303885" xl:show="new">C0303885</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e047c57e-04d2-41c0-98f8-b1266afacde0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9e3e869-6574-4a13-8d4b-c05d1697e7fa">
                                <link xl:href="http://snomed.info/id/89148006" xl:show="new">89148006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e8a173c2-a151-42ec-ae51-81c0a36288dc">fast garnet GBC salt stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4aa4c05a-ba3f-46f6-8019-d4c68d310c11">
                                <link xl:href="http://snomed.info/id/89148006" xl:show="new">C-22882</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c702897b-a623-42e3-9c94-5d699a87c40e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303887" xl:show="new">C0303887</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76963de6-bf4a-4df0-9c68-50d9204ab0cd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ab42e02c-ec99-466f-ae87-72d9e68ac892">
                                <link xl:href="http://snomed.info/id/24167004" xl:show="new">24167004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0a4b2e0b-35db-4b45-95c3-5e4abfbb965d">fast green FCF stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8bfe4058-1c38-455c-9d39-e59119ab4031">
                                <link xl:href="http://snomed.info/id/24167004" xl:show="new">C-22886</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c8deeab-3c89-443d-8715-4a8523a4d272">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0060087" xl:show="new">C0060087</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21e4456a-0fcf-432b-9b5d-b937021e94a1">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54056da9-d933-482d-9dc7-b01bfcf16ec3">
                                <link xl:href="http://snomed.info/id/40718007" xl:show="new">40718007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3b0673dc-f237-479a-b149-97661ef6e29a">fast red B salt stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7237ad11-0a25-4927-9356-af4ba4e28f53">
                                <link xl:href="http://snomed.info/id/40718007" xl:show="new">C-22876</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bbf7d64c-116a-42af-85da-b1b4841370c8">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303883" xl:show="new">C0303883</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fece7e20-05e1-47ce-ae80-d53691bdf433">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20607448-ee74-49bf-9272-412374e5b2f0">
                                <link xl:href="http://snomed.info/id/47486002" xl:show="new">47486002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3020ae7c-e6a3-4c90-90d3-c1260fdb07cc">fast red ITR stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e923354-f281-47c3-8338-4729151ace98">
                                <link xl:href="http://snomed.info/id/47486002" xl:show="new">C-22877</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5685e2aa-67e9-491f-8c73-d4b1723f5fef">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303884" xl:show="new">C0303884</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5141b4e3-8c09-419f-aff3-0d4e59f2b203">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b921b097-0852-470d-a177-4b68b80472bf">
                                <link xl:href="http://snomed.info/id/76633005" xl:show="new">76633005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_42cf1b1e-542a-44da-8fb4-272adea72973">fast red TR salt stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a4975621-e09f-40a5-a13f-44b33cddc889">
                                <link xl:href="http://snomed.info/id/76633005" xl:show="new">C-22875</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_062aba20-9361-460d-9197-6de214d052e6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0950478" xl:show="new">C0950478</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7dd80746-bccf-4673-9978-3cf6eb32e5d9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37dab10a-9f79-48e5-879d-a6e61249f847">
                                <link xl:href="http://snomed.info/id/88660000" xl:show="new">88660000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b0272f90-c7fc-4481-8490-26c2b6e26af8">fast sulfon black F stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7fb74fa3-cf2a-4105-80dc-b1a9b498c7d6">
                                <link xl:href="http://snomed.info/id/88660000" xl:show="new">C-22867</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_41d93613-c32f-4469-ac21-50444c8fdb53">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303879" xl:show="new">C0303879</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b98abb64-8507-4f5e-b200-58830875eef5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8e98296d-195e-4a73-9cd7-94926c0e29e6">
                                <link xl:href="http://snomed.info/id/72371006" xl:show="new">72371006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_493acb56-4b10-4e56-9870-48a4f13236b0">fast violet B salt stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e9f6c84-116f-4961-b90b-13baf8a328d1">
                                <link xl:href="http://snomed.info/id/72371006" xl:show="new">C-22879</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba0c9532-a733-42f2-86f9-841559e38ec9">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303886" xl:show="new">C0303886</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8baa7ca7-818f-4972-9397-7c3c403ecbbe">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0987f190-a9aa-4aec-8480-2c44ba98e279">
                                <link xl:href="http://snomed.info/id/76439002" xl:show="new">76439002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0173681c-f5be-4cab-90df-4c117ddc1734">fat red 7B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3428ea6-9852-4354-bb85-046f5c94bc16">
                                <link xl:href="http://snomed.info/id/76439002" xl:show="new">C-22859</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04c07b76-c810-4814-a0ae-48d0a4600587">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0117300" xl:show="new">C0117300</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78f4cc71-35d5-433f-82eb-e5fd080a8f4e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_365a9a34-eb10-4982-92fa-0fc4dd677239">
                                <link xl:href="http://snomed.info/id/255797007" xl:show="new">255797007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_27710b3f-63ba-4bdc-9d00-d8fe396579eb">Feulgen reaction stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b830e2af-1701-4fde-b212-094509011284">
                                <link xl:href="http://snomed.info/id/255797007" xl:show="new">C-2280F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec68140b-e6b8-4c55-ba6b-1dc856430bb6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440041" xl:show="new">C0440041</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a340da27-4aff-47ed-8a8f-aa6bfa192a95">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_991c8036-afcb-479c-b7cf-853f0f7765d9">
                                <link xl:href="http://snomed.info/id/255798002" xl:show="new">255798002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_05c98283-2201-4736-b8af-48fcd575c0e9">field's stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b7ab365c-3089-4816-8db7-51d9efe3ce7d">
                                <link xl:href="http://snomed.info/id/255798002" xl:show="new">C-22810</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66467edd-8540-42ab-9df3-27ce69d032bf">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440042" xl:show="new">C0440042</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d70040b0-450f-4b8b-bd9c-4022998c3bb0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3f84740-f45e-421f-9005-9e72a8d5bc46">
                                <link xl:href="http://snomed.info/id/255799005" xl:show="new">255799005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1c5c21ea-d29a-446d-b279-bb73e1505080">Flagellar stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ddfac1ff-9c78-4d80-9fe5-3a65bf0b7a97">
                                <link xl:href="http://snomed.info/id/255799005" xl:show="new">C-22816</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_15a13932-4e57-4c4a-ac5d-b2ab81a91c82">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440043" xl:show="new">C0440043</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a74dfd22-e72f-4adf-914e-928c103c4136">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d2099cc-c577-4f50-8a8e-3d0d14312062">
                                <link xl:href="http://snomed.info/id/35352008" xl:show="new">35352008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f7206c83-381d-4a2e-a90a-221b6d5c2e0e">fluorescent stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f02d8b26-654a-4675-b89c-8c02c5b709b4">
                                <link xl:href="http://snomed.info/id/35352008" xl:show="new">C-22A00</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e1ceb58c-e2f4-45cb-a112-3d4df4bcec8e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303920" xl:show="new">C0303920</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_48392716-eca0-4d4e-98f7-4db898f395b2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_75e92bba-d28e-47cb-836a-bd9a1822b7c6">
                                <link xl:href="http://snomed.info/id/406980006" xl:show="new">406980006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_80ac2aef-973f-45d2-9430-8d88c6c28c03">fouchet stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0493a580-ddf6-4f43-84f2-e64097f59a27">
                                <link xl:href="http://snomed.info/id/406980006" xl:show="new">C-2286C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44698a59-7b7f-4906-ae71-6399199a1487">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318722" xl:show="new">C1318722</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ea1d82e-e3db-46fa-9876-3c0ae33ec3ab">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_166a0564-0190-44db-b22b-22e69c5c260f">
                                <link xl:href="http://snomed.info/id/60920007" xl:show="new">60920007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_33af0214-4865-43ab-af2e-f740f93ac06e">fuchsin acid stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08cd9372-0508-4d09-8667-a1d90fd50eea">
                                <link xl:href="http://snomed.info/id/60920007" xl:show="new">C-22902</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fcc8eaa5-5d04-4258-90b4-c71a1794b132">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0252873" xl:show="new">C0252873</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_138ac8bc-f748-40c3-9504-de52ebffacc6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4bcc0786-c958-4b62-86b6-3bb2b80261b9">
                                <link xl:href="http://snomed.info/id/50062004" xl:show="new">50062004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5adef829-32ff-4a9c-8e3a-465d73aed373">fuchsin basic stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_383cf2d8-c0fb-48c5-866c-33d22d674f5c">
                                <link xl:href="http://snomed.info/id/50062004" xl:show="new">C-22889</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c793d4e0-7d56-4d1c-b6f9-5884380dcdee">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0073578" xl:show="new">C0073578</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aac12298-ecda-4a4c-80c7-ddc683e8f44e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c489ab8e-a507-46ba-a91d-fb510257c512">
                                <link xl:href="http://snomed.info/id/8836009" xl:show="new">8836009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7d7278ea-57e0-4ce2-b22d-7208e348c503">gallocyanine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98c931fa-f669-496c-9414-71fd631021e0">
                                <link xl:href="http://snomed.info/id/8836009" xl:show="new">C-22935</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90fe516d-7ba7-49d6-9816-a696c5e6253f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0061013" xl:show="new">C0061013</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_670386e2-3c94-44df-bc0b-9f32261ede15">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_33d4208c-f35a-4814-bf32-ed595be48620">
                                <link xl:href="http://snomed.info/id/373646006" xl:show="new">373646006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7dea245d-489b-497f-9d50-9706bad13d18">giemsa stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4dffe50e-938d-4e47-933d-fe0e6b431749">
                                <link xl:href="http://snomed.info/id/373646006" xl:show="new">F-61968</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2a88ec4-3c88-458a-88a4-115747c252b4">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0017542" xl:show="new">C0017542</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62d302c1-79ac-4b94-83c2-55f0d5cada32">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4b122c3-80ab-49f2-86d1-9f4abc69c50d">
                                <link xl:href="http://snomed.info/id/385484003" xl:show="new">385484003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1a549fb9-83a6-4dd3-beae-d0f64e8bd5c9">gram stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1296e2e4-2996-4cb3-92ca-ca45968ba392">
                                <link xl:href="http://snomed.info/id/385484003" xl:show="new">C-22830</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96aba706-a554-41f2-b4b9-538b6b7fa181">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0061856" xl:show="new">C0061856</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c44557a8-c170-4ba4-b8ad-68aad3780106">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd633b7b-41d6-41d7-9051-381974d47e14">
                                <link xl:href="http://snomed.info/id/406983008" xl:show="new">406983008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0380f8a5-d08c-40fd-b8f6-1a37086db2fb">hansel stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_744c1302-ffb5-4fc9-b545-84b8d18d29e3">
                                <link xl:href="http://snomed.info/id/406983008" xl:show="new">C-2286F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f45f35c-2a61-4cd4-a304-388262277b90">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318724" xl:show="new">C1318724</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f79cb8ca-ba0a-4a48-b364-8eb97ac723e4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_51e941fa-3a31-4d3f-ac6b-b119bd3a32df">
                                <link xl:href="http://snomed.info/id/75956008" xl:show="new">75956008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a8c7265b-e8f7-421b-9117-f1565a6dca6a">hematein stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b0301a0b-1963-44b9-b50a-afa3fe47bca5">
                                <link xl:href="http://snomed.info/id/75956008" xl:show="new">C-22967</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_801f1ebd-ddfc-44b0-8d08-e4f0515b7b06">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0062204" xl:show="new">C0062204</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ffb9d794-19c9-430a-9d40-4c96ad515c7e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ade9d40d-a90d-4e70-8d96-a3ede53ab1fd">
                                <link xl:href="http://snomed.info/id/12710003" xl:show="new">12710003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_85c1674d-7aa4-40a4-a73c-72facffd28eb">hematoxylin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86b23904-e23a-48b4-810f-a59c80a52b5e">
                                <link xl:href="http://snomed.info/id/12710003" xl:show="new">C-22968</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2baac38-6aab-40cd-a439-02e1ba6c47e7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0018964" xl:show="new">C0018964</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc97eef1-041b-41ad-8e70-cb8b9141cbc4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63d6cfe9-7ab9-47b6-bc10-464a8cd44753">
                                <link xl:href="http://snomed.info/id/255800009" xl:show="new">255800009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c885fe5e-1822-4d99-b090-3728ca910ca0">immunofluorescent stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6937e4d-a5a3-421b-8a9d-3ab577e3ace3">
                                <link xl:href="http://snomed.info/id/255800009" xl:show="new">C-22817</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_30e54c14-bd48-4920-81fc-b7408740015b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0183489" xl:show="new">C0183489</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3092da17-9ed6-47ff-9f38-afa5318e92b4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc205e7e-a7bb-4b5a-b8de-cc2ae993afd9">
                                <link xl:href="http://snomed.info/id/406972004" xl:show="new">406972004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e4c31397-ae02-4af5-a18a-c2134721e94b">India ink stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96a7767e-bc2e-4a97-bfcd-1a986d5bbabe">
                                <link xl:href="http://snomed.info/id/406972004" xl:show="new">C-2285C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ec3b7f1-d8ff-46d6-8a9f-82bb5f61b6c7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0123471" xl:show="new">C0123471</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1fd4b6ca-e840-4e14-acc6-fb97717341c0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9fdf1f94-fbcd-4474-9154-d515e3b5c52c">
                                <link xl:href="http://snomed.info/id/45475000" xl:show="new">45475000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8ba7bb26-356e-4a29-8959-899d85fbd43d">indigo carmine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_48789deb-b6d2-4e53-aef7-c228efdcf366">
                                <link xl:href="http://snomed.info/id/45475000" xl:show="new">C-22962</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78a3ad1e-f286-4961-bc64-6d8db36f0c6d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0021219" xl:show="new">C0021219</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f85757ec-fbec-4038-b0e9-16accd493475">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1bf43388-f97e-4677-860e-5e14fa114e36">
                                <link xl:href="http://snomed.info/id/11727009" xl:show="new">11727009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_31a55325-858a-4318-a24f-9b5667f3227a">indophenol from naphthol stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5d3f8cd-5515-4f71-912c-eeef5d240c13">
                                <link xl:href="http://snomed.info/id/11727009" xl:show="new">C-22927</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56c900e4-46d1-405d-a56d-dc55606ff80d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303906" xl:show="new">C0303906</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_385afc9c-6022-488f-93ca-175df7e5d0ca">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1126f3cc-1773-4215-8857-db87c5dc01f8">
                                <link xl:href="http://snomed.info/id/47030008" xl:show="new">47030008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_74b975bf-e924-4c32-8885-1dd92694b6e5">insoluble berlin blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46b972aa-9f0d-4304-910d-1e3dd17c7cf6">
                                <link xl:href="http://snomed.info/id/47030008" xl:show="new">C-22974</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6af3dd63-e734-44ef-bcc6-f269430f16d4">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303918" xl:show="new">C0303918</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44fe4b79-622e-49ef-99b6-ab5e18269fc3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9b92e441-04d3-4a19-a3be-5a24d565e305">
                                <link xl:href="http://snomed.info/id/68263003" xl:show="new">68263003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fe70e784-1563-4bcd-aeb5-c8ebac689578">janus green B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_51caf50b-b1fd-4188-adf7-75a726aeda2a">
                                <link xl:href="http://snomed.info/id/68263003" xl:show="new">C-22804</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_afa58b0d-9bfc-4953-8a22-ef1ecf2da3fb">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0064136" xl:show="new">C0064136</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19881092-085e-4487-a879-2482ab599177">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7c58f16-06f5-4171-82b4-ebd9bd870378">
                                <link xl:href="http://snomed.info/id/255801008" xl:show="new">255801008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ab24a961-7824-461c-8e32-323a66b9956b">Jenner-Giemsa stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ab0aa8b-8a37-4a6a-baa9-cf47403e7915">
                                <link xl:href="http://snomed.info/id/255801008" xl:show="new">C-22818</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a78e950-a6e5-4ed3-ba77-d330b35a95be">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440044" xl:show="new">C0440044</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bf460493-a82e-4c43-9307-8df7213bee04">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1bc95376-6992-43e4-98ce-e381673b0bc5">
                                <link xl:href="http://snomed.info/id/29342009" xl:show="new">29342009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_97e4d20c-f015-443b-a9d5-096b95ab9070">kenacid blue R stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0bdbde86-072c-4c35-a812-77cbcb1c8139">
                                <link xl:href="http://snomed.info/id/29342009" xl:show="new">C-22899</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_554e2b68-fa83-4132-9152-733496194210">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303892" xl:show="new">C0303892</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_434f370e-6b3c-429a-88b0-356d2b0304d7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_829dcc7b-99a6-4282-a494-0bceb08c25cf">
                                <link xl:href="http://snomed.info/id/35724001" xl:show="new">35724001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4ec5490d-0831-4c34-94b3-2b2be7782d0c">lacmoid stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ab5e862-4d19-42b9-b83e-0907b37d808c">
                                <link xl:href="http://snomed.info/id/35724001" xl:show="new">C-22942</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a0fbf303-e0ba-401e-a51d-1d81355634e1">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303910" xl:show="new">C0303910</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e1961c0f-9a0f-4046-a1a0-d52b4bcf2764">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57fe0db6-eb67-4f88-9b4e-e990de9324b5">
                                <link xl:href="http://snomed.info/id/255802001" xl:show="new">255802001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d578e487-3eba-4c4f-ab11-e3c3aba6121b">Leishman stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_51ae0bc9-3689-4efa-ac21-1f3b30b8f11a">
                                <link xl:href="http://snomed.info/id/255802001" xl:show="new">C-22819</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da856f90-3ae2-473e-90d4-98b904bd3365">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440052" xl:show="new">C0440052</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8164641-63c1-4743-906c-ab27a033deac">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_02705484-0bf6-49b1-8c84-9b6f31da5e1d">
                                <link xl:href="http://snomed.info/id/89139001" xl:show="new">89139001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_647e8aa3-501d-4fae-a3ba-5536507fb802">light green SF stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63b3286f-c9b4-466c-a99f-af41efc93656">
                                <link xl:href="http://snomed.info/id/89139001" xl:show="new">C-22887</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_afb990f9-2fe4-4099-80c1-2dc5a5edeacd">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0064970" xl:show="new">C0064970</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f7692e7-4ca6-41e7-a587-4281349e8441">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8a96a360-8590-47ed-bf63-a2700d0aa641">
                                <link xl:href="http://snomed.info/id/6701008" xl:show="new">6701008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f9ce184d-da4c-4718-9d87-06a8a8bfdcfd">lissamine fast red B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c5bd8e09-3dc5-4017-a7fd-e1fd7395f93c">
                                <link xl:href="http://snomed.info/id/6701008" xl:show="new">C-22841</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_113f9568-1fe4-4ae0-b813-4e0f1e2e6703">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303868" xl:show="new">C0303868</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5670f125-9201-4bfc-b1a9-aec6dcd5d536">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d0e4a27-1ae9-4720-acb6-b73c23d589f3">
                                <link xl:href="http://snomed.info/id/25079009" xl:show="new">25079009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_84390b88-6026-4031-8ef0-669d3f253956">lissamine fast yellow stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d9d52b4-7bf5-4c32-85c2-af8da7000003">
                                <link xl:href="http://snomed.info/id/25079009" xl:show="new">C-22843</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9a3702d5-d206-4ea1-8b76-16163487442d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303869" xl:show="new">C0303869</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fb49472c-7d1b-45bd-8661-638dfdbe5c96">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4615b479-121b-4dab-80dc-118264502efd">
                                <link xl:href="http://snomed.info/id/38543004" xl:show="new">38543004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_06721b9c-0fdd-4e08-a670-1123d804648e">lissamine green B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c53b1c8e-feaf-47ac-98fc-b10049c9d24e">
                                <link xl:href="http://snomed.info/id/38543004" xl:show="new">C-22914</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8124352f-5048-40fd-bf86-7177c1970ea2">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0061890" xl:show="new">C0061890</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e58efb11-ec22-4665-bbed-21c3b055b0ae">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7984b9d-078d-4d2a-a7cf-f3b9f105a706">
                                <link xl:href="http://snomed.info/id/111102009" xl:show="new">111102009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4eb4886a-c4a6-4741-a37a-2feb7723ffd6">lissamine rhodamine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a38d8155-8326-4cec-85be-1d5917380884">
                                <link xl:href="http://snomed.info/id/111102009" xl:show="new">C-22917</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6b19c3f-4158-4cca-9344-e94aef1c32ce">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303900" xl:show="new">C0303900</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f94ff0bd-c316-4f82-9664-bbb82d653091">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df5e8140-c6fa-4f16-a197-43b4d30b50b0">
                                <link xl:href="http://snomed.info/id/406958008" xl:show="new">406958008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_88638d5c-e711-443d-9779-5659222ec3ae">luxol fast blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4010e5a1-e0a3-484a-b0d0-f816fef422fa">
                                <link xl:href="http://snomed.info/id/406958008" xl:show="new">C-2283F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3edee4f-8612-4962-8831-9bcd80b27be7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0065274" xl:show="new">C0065274</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_31185fcc-53cc-4901-bd51-6410a9e05c82">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_856ef1ce-f4d8-4a91-a188-dec3eba37bc8">
                                <link xl:href="http://snomed.info/id/27120008" xl:show="new">27120008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a92dfa64-69ab-4b70-b24f-14ba8de84d5f">malachite green stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc0ce676-392c-4d81-a4ed-c1b05adff70b">
                                <link xl:href="http://snomed.info/id/27120008" xl:show="new">C-22890</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24becada-232f-4676-bae8-742c97b32b3c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0065555" xl:show="new">C0065555</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_387a135d-62e4-42d0-af00-40affca705e9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_341c4712-fa22-450d-8057-fe53a04cf52a">
                                <link xl:href="http://snomed.info/id/406953004" xl:show="new">406953004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_47e02914-78aa-41d7-bb3f-daf33b8884e8">Mallory bleach stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87111c5c-bc33-43f8-ad78-b7cce44e92b0">
                                <link xl:href="http://snomed.info/id/406953004" xl:show="new">C-2283A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1eb1003-2b4c-48a2-8cf3-bae8b68b7d56">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318878" xl:show="new">C1318878</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b5857ba5-9301-4855-8c3e-0bec2252da10">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7fc2d6b0-a525-42f5-b10b-7d01db29c562">
                                <link xl:href="http://snomed.info/id/46139004" xl:show="new">46139004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_57c31f96-b51e-4aaf-8125-854a97a013e4">martius yellow stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_567376c5-4acf-494b-8750-8e5e2de4db62">
                                <link xl:href="http://snomed.info/id/46139004" xl:show="new">C-22802</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da6d7576-e3cf-4ddf-8f3c-695b02ed8847">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303860" xl:show="new">C0303860</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d8b0c6f4-3b73-4e56-a3e9-354173fb0826">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_522376e9-dd8b-4e6c-a2d9-41bcc34f0a48">
                                <link xl:href="http://snomed.info/id/255803006" xl:show="new">255803006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_155a9a6a-2455-4c29-b797-1afb6326fca6">may-Grunwald giemsa stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5464ec9e-568b-4c4e-9e77-b02c14d50940">
                                <link xl:href="http://snomed.info/id/255803006" xl:show="new">C-2281A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_439ad5e4-3b2d-4b2c-9c23-0c9f0833b93b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0065757" xl:show="new">C0065757</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_425524de-a843-4f0d-9dff-d5f8f6f299dc">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3bb5c98e-7816-45f4-8dda-dff6bde72908">
                                <link xl:href="http://snomed.info/id/24516006" xl:show="new">24516006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a8b5d72d-663d-42b1-ad3b-961581e000de">meldola blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53b24560-fcd2-48c5-85ac-abc65782319c">
                                <link xl:href="http://snomed.info/id/24516006" xl:show="new">C-22937</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_409a487a-bf0d-4640-80d6-db325560b1b8">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0065912" xl:show="new">C0065912</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_02c2fbc4-e0d3-4942-8fb0-4617bac1579c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b272736-1b0f-4425-928d-881a93433fa4">
                                <link xl:href="http://snomed.info/id/54791001" xl:show="new">54791001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c895bce1-d469-4aba-9d19-ce07d52b4e0a">metanil yellow stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df9de634-d18d-41ee-abad-b835730f1eab">
                                <link xl:href="http://snomed.info/id/54791001" xl:show="new">C-22811</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a1eb06d2-977d-40f2-a42a-945244601607">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0066052" xl:show="new">C0066052</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0924f1ca-123f-41cd-8e37-1735ac855ed2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f34b9a5-1d6a-4b04-b404-6b07b5ee202e">
                                <link xl:href="http://snomed.info/id/9010006" xl:show="new">9010006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_59f93ff7-6b3e-4f4e-85ff-5dd18240bdc5">methyl blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f0c3f2b-313e-486a-bf98-df7fe811e3f6">
                                <link xl:href="http://snomed.info/id/9010006" xl:show="new">C-22907</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6022754-4062-4f5a-9e53-5b4891b0a1e6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303897" xl:show="new">C0303897</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_434b8674-ddf0-4719-afe7-9dd408db0f20">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a027dde-fa3b-416c-903a-f952b58c32d7">
                                <link xl:href="http://snomed.info/id/255804000" xl:show="new">255804000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a61c6e26-0221-406d-984b-450804fbbf8a">methyl green pyronin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_34f7a8f1-a728-49c5-bb3d-34951a6651a2">
                                <link xl:href="http://snomed.info/id/255804000" xl:show="new">C-2281B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de715134-5a35-4ff8-ad78-2f335b9db315">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440045" xl:show="new">C0440045</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ef43165-9947-4ef4-a148-50a5afc0c215">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_083bd5b3-fd4e-4070-96b4-ba488cd1253a">
                                <link xl:href="http://snomed.info/id/42248000" xl:show="new">42248000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dd7ed866-610a-4c2e-b608-a3694d8dcd6e">methyl orange stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_55fd1d5b-b920-4f1e-9a30-5b1f0487e144">
                                <link xl:href="http://snomed.info/id/42248000" xl:show="new">C-22809</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_210adef3-c30d-47ba-863a-7f824c150ae7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0066274" xl:show="new">C0066274</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d565436-b899-4d19-bd6d-c47d04e98996">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4cb997b4-a7d8-4240-845f-2cbcde4eb898">
                                <link xl:href="http://snomed.info/id/13744001" xl:show="new">13744001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e445819e-710c-4c02-98c0-3cec88fe17f0">methyl red stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d27310a9-acb8-453a-a0e6-388e15071b56">
                                <link xl:href="http://snomed.info/id/13744001" xl:show="new">C-22808</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de9e02d8-84d4-479e-82b8-c9e077e59b25">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0066279" xl:show="new">C0066279</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b7e8cf9b-5fce-4d47-a2b5-9a95dc1aaf63">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e18dd472-0613-49d9-810c-9ca123241a4f">
                                <link xl:href="http://snomed.info/id/387239001" xl:show="new">387239001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_40a83240-321d-4cd1-bddd-d6962312ffc3">methyl violet stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_708210c7-dc36-4c42-9298-840d69fb7f7a">
                                <link xl:href="http://snomed.info/id/387239001" xl:show="new">F-61A76</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66a4d3cc-063f-4c77-a5e6-b431dc6dc41a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0017440" xl:show="new">C0017440</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2ac911c-341c-4d92-bc2b-77c1219826eb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62bb4aa2-5d84-4280-bfab-1569dea887ad">
                                <link xl:href="http://snomed.info/id/6725000" xl:show="new">6725000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9cc6c647-b9f7-4edc-adf2-60cbb205ca13">methylene blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2580484-821a-4be3-a66f-acf8bc4c565a">
                                <link xl:href="http://snomed.info/id/6725000" xl:show="new">C-22947</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_393b4301-d3d2-40f2-9f4f-746cc43a3c2a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0025746" xl:show="new">C0025746</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2ae3deb-a624-4b2a-89a0-a249c63f312c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_229b248a-bc68-45c4-8fcf-1ec0a623b1f0">
                                <link xl:href="http://snomed.info/id/406961009" xl:show="new">406961009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6ffa7887-33a5-4f2c-af0d-5b22225bf187">methylene violet stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92de8d29-c223-4b13-ac5f-da50db625ab6">
                                <link xl:href="http://snomed.info/id/406961009" xl:show="new">C-2284A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf81022a-af2f-4d3e-83bf-f26572fdfa3e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0492805" xl:show="new">C0492805</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_151fa9f2-ccbe-42a2-a5c6-6ad271f24b68">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7eff9266-989b-47ce-bd33-7f8fdf5a8a78">
                                <link xl:href="http://snomed.info/id/31260003" xl:show="new">31260003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3c282b7d-510e-482a-8f84-c4bf06ccc3cd">methylene violet stain (Bernthsen)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0fbc38ee-a251-4291-bf5f-24e68efb6355">
                                <link xl:href="http://snomed.info/id/31260003" xl:show="new">C-22952</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c9af51d-1fed-4fc2-aaf8-8b0ce26b800d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303911" xl:show="new">C0303911</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4587b8ec-18bf-401b-9c96-a4b5036ae6c7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9048d389-49a4-4429-ab99-22b6b3c57e4c">
                                <link xl:href="http://snomed.info/id/406991004" xl:show="new">406991004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1c15103c-ea4c-4bd7-887c-189bb9e17f45">modified trichrome stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef35d96e-5f60-480c-8779-4bd12cfc1f0c">
                                <link xl:href="http://snomed.info/id/406991004" xl:show="new">C-2287F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1237b62d-9cb7-4f7d-8cbd-125fb8ede8ed">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318726" xl:show="new">C1318726</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef438835-8af8-4229-9761-9653d1b6093d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_058c8595-2234-4fb5-bea4-9e84deef19fc">
                                <link xl:href="http://snomed.info/id/406964001" xl:show="new">406964001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4458950c-e064-498f-8e36-ed39ef5a2504">mucicarmine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b824af4e-276e-4b27-8dce-cd6ef56bb332">
                                <link xl:href="http://snomed.info/id/406964001" xl:show="new">C-2284B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f236ff30-eaf1-48e2-a521-75a33efdb7a0">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0066912" xl:show="new">C0066912</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14c021b1-171a-4d18-b6cf-c70c1a166e8c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d3068d4-c758-4947-b581-20ccb877a91b">
                                <link xl:href="http://snomed.info/id/255805004" xl:show="new">255805004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d924cdf3-e3dd-4c49-980a-56218fd8eb54">myeloperoxidase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92569509-ca51-467a-b5b7-3d30c3723811">
                                <link xl:href="http://snomed.info/id/255805004" xl:show="new">C-2281C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ee3a281-7fde-4e73-944f-41998b6fc197">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440053" xl:show="new">C0440053</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92ab1421-1ef7-4fda-96c6-6003921c7636">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11d193e8-2382-4318-a52f-87cb3d478242">
                                <link xl:href="http://snomed.info/id/16788000" xl:show="new">16788000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_47e11a33-b04b-4c91-b191-b6fb61f2b3bd">naphthalene black 12B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56cf1410-f227-49bc-9590-84788e51b934">
                                <link xl:href="http://snomed.info/id/16788000" xl:show="new">C-22846</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3858f36-bb92-4fd4-9440-cbc362a681ea">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303870" xl:show="new">C0303870</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d76fcdff-d5a6-47e1-9f2e-3e45b460f593">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef114e7e-e759-42f2-9eee-b59f825eefde">
                                <link xl:href="http://snomed.info/id/14958002" xl:show="new">14958002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5a39a1cc-f112-433f-b9ee-a05a0721d903">naphthol green B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3d102a8-720f-4f81-bf40-ee443819c790">
                                <link xl:href="http://snomed.info/id/14958002" xl:show="new">C-22801</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83afa1d7-0d73-4c53-8ffa-980f8995cf89">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303859" xl:show="new">C0303859</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6bd84b19-b869-4f40-aac4-96488113ea15">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c60ed309-bde2-47d8-81d3-de8f1222c72f">
                                <link xl:href="http://snomed.info/id/111101002" xl:show="new">111101002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_62b218c0-e243-4af5-9c50-bc4c1a9975b2">naphthol yellow S stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_936035ab-01a2-4f1f-948e-b67bfe90927d">
                                <link xl:href="http://snomed.info/id/111101002" xl:show="new">C-22803</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60a11525-16cf-4ad8-acf2-24cf4d429024">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0068424" xl:show="new">C0068424</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2b201f81-8c68-4c07-93b6-9c6fd0064add">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a25cacd9-b258-446f-a373-bd71bdaed83a">
                                <link xl:href="http://snomed.info/id/406973009" xl:show="new">406973009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e58e8d8a-60e6-4804-8df6-12f06b568c48">naphthol-AS-D-chloracetate esterase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a75d9121-6d05-41a6-9ed1-561690e1ba72">
                                <link xl:href="http://snomed.info/id/406973009" xl:show="new">C-2285D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56470096-1218-4d39-9b84-26a4caa01b4a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318718" xl:show="new">C1318718</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_72a82f77-ccd8-4adb-b4d5-a76f0b1b1787">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4997123e-75e8-4a36-85c8-bfdb9e2a64c1">
                                <link xl:href="http://snomed.info/id/67956008" xl:show="new">67956008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2b4f804b-19c7-4e8e-9a54-c62f72c94bfe">neutral red stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90237ffe-f824-4c54-a60a-e4dc0679face">
                                <link xl:href="http://snomed.info/id/67956008" xl:show="new">C-22928</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9907cda-a475-4626-a66c-67713829b5bc">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0027941" xl:show="new">C0027941</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b65eb55a-37d0-45d1-a2b0-61ee535c4bbf">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e81b23b8-e93d-45f9-9278-ebeb58f5e2ab">
                                <link xl:href="http://snomed.info/id/255806003" xl:show="new">255806003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_852c319c-d9c4-47bf-8c96-05ec5c7e7f98">neutrophil alkaline phosphatase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76664535-61cb-4aa5-85e0-56dbdf7f5385">
                                <link xl:href="http://snomed.info/id/255806003" xl:show="new">C-2281D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa4343d4-a925-4554-8734-fbf555278e90">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440046" xl:show="new">C0440046</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1301bdb-38ce-48ad-839f-b8a67c18901e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a947b422-2ced-4b40-b4d8-9dd0e857841d">
                                <link xl:href="http://snomed.info/id/31714001" xl:show="new">31714001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bffb552c-d4ff-41a8-a3d7-853b936d6dda">new fuchsin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6efb0f44-a879-40f9-afd6-b38bb06d2da4">
                                <link xl:href="http://snomed.info/id/31714001" xl:show="new">C-22891</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5675086d-7cb9-4ae7-bebc-dab2db65a0f4">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0068661" xl:show="new">C0068661</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da0983e6-0fb8-46ab-b2ad-7f82631df3d3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9318c37-6be8-4a0c-8378-1926045ce765">
                                <link xl:href="http://snomed.info/id/406965000" xl:show="new">406965000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9a5b6577-78ab-4fe8-8869-abace031720a">night blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47bfd712-b4ed-4a1e-8267-4f695d86ebf5">
                                <link xl:href="http://snomed.info/id/406965000" xl:show="new">C-2284C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8dec915-30a0-4b21-a94b-521da600474d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0068751" xl:show="new">C0068751</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2c2a92e-80b0-4743-884f-2d43d6decf91">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ca779d6-4faa-4a5d-9d43-ee05a52eb0b1">
                                <link xl:href="http://snomed.info/id/77073008" xl:show="new">77073008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ad187718-869d-4b16-bc61-d38418144346">nile blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c76f1a0-7dde-4119-b4a6-5e1bcf4e6d71">
                                <link xl:href="http://snomed.info/id/77073008" xl:show="new">C-22941</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f55652b9-20ea-44c1-af82-dccee13c6ae6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0068765" xl:show="new">C0068765</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_29beeeba-a46d-4bcc-82ef-c7af5b6cd6e9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff2a7a20-757f-4f77-8bb7-0517f7a47665">
                                <link xl:href="http://snomed.info/id/86750008" xl:show="new">86750008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6aa1cd2f-211f-4610-aefa-b733171b122f">nitrazine yellow stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc7c462f-cc38-42b2-b915-f18eb40efc5d">
                                <link xl:href="http://snomed.info/id/86750008" xl:show="new">C-22823</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b41bc091-60f5-4521-a9ec-c105d3d3a8a3">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0068806" xl:show="new">C0068806</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d451c61e-b130-4199-a320-b5ac998808ee">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83e795e2-f82d-443c-bdc9-ea4bb92e4b6d">
                                <link xl:href="http://snomed.info/id/255807007" xl:show="new">255807007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6396b9de-150d-4c4d-9ff3-314f97cf8bc9">nonspecific esterase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0d6f1a90-b5a1-4401-8b93-7476592432cc">
                                <link xl:href="http://snomed.info/id/255807007" xl:show="new">C-2281E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8bb84702-c942-4045-9804-fe45be143399">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440047" xl:show="new">C0440047</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70b574b0-104f-4551-9d21-9c8fe7cb72e9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1a5743b-dcbe-461e-b222-40df23077561">
                                <link xl:href="http://snomed.info/id/78869007" xl:show="new">78869007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1e7067c1-4617-4c1a-b1cd-4efc228903be">nuclear fast red stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96bcf88f-9a67-4b07-b02a-454ab728a61d">
                                <link xl:href="http://snomed.info/id/78869007" xl:show="new">C-22955</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38bca27a-5277-4f24-8b65-dadb6d265cd1">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303913" xl:show="new">C0303913</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6536385e-c15a-4001-b0a2-3aab81534f93">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d02b627b-a90d-4a00-8c91-64d5921db092">
                                <link xl:href="http://snomed.info/id/40808006" xl:show="new">40808006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9f3210e4-9439-4a56-b6b9-79c7b7a4f689">oil red O stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3a1b0c6-c068-4e60-97be-a034836c8ba6">
                                <link xl:href="http://snomed.info/id/40808006" xl:show="new">C-22863</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04301df6-14a5-4f18-870c-69a4fadabbe9">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0069388" xl:show="new">C0069388</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad21957c-c5a9-4657-81d0-98f85f4df747">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_48dccfd5-cf19-40bd-846c-57e874d1fd0a">
                                <link xl:href="http://snomed.info/id/54221006" xl:show="new">54221006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8dd946f0-fc50-4ab2-8945-83592bf095e3">orange G stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b2578b94-5871-433a-bf0d-194e9e9d69e4">
                                <link xl:href="http://snomed.info/id/54221006" xl:show="new">C-22832</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_345c6a72-ca28-4930-bf8e-1fcbbd478df3">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0069591" xl:show="new">C0069591</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c689aa4-a829-4963-8859-57d221c39969">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fdcbc1cf-6f67-488c-b5e8-6be11de5b63f">
                                <link xl:href="http://snomed.info/id/25941002" xl:show="new">25941002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_147e637a-b4f4-4e93-8504-9b2e67315276">orange II stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3aea8227-d47f-4b67-be5a-598dbf0d3eef">
                                <link xl:href="http://snomed.info/id/25941002" xl:show="new">C-22824</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5be05eec-6ed6-4020-a07d-bf408df9b30b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0069592" xl:show="new">C0069592</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0544aca-1aad-4953-b52d-0241fbae4174">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb4cf67e-591d-4b59-ad9a-186817ba0465">
                                <link xl:href="http://snomed.info/id/406966004" xl:show="new">406966004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_534f69dc-c5d5-4c66-804f-de4048920f37">orcein stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_13e920fe-52c5-46dd-8507-772597298af3">
                                <link xl:href="http://snomed.info/id/406966004" xl:show="new">C-2284D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_95aeaa03-4f6d-4851-a874-d999da806ee6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0069596" xl:show="new">C0069596</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_236de937-5bf7-43dc-bc3f-46a867d9299a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2d8d4d2-8ad2-4a03-9ec6-8d3e63da71dd">
                                <link xl:href="http://snomed.info/id/5442001" xl:show="new">5442001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2abd12de-b422-4b8c-a74f-bfa87025edd8">page blue 83 stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7cc1f98-1ef0-445c-8c3b-04f4a0878478">
                                <link xl:href="http://snomed.info/id/5442001" xl:show="new">C-22901</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_381fcfa7-c699-42b5-8137-763fed614d85">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303893" xl:show="new">C0303893</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89051809-19ae-449b-a0ae-78d7c74925b8">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d7116a0-2cb1-4cc5-a4dc-f8db9ec96e2f">
                                <link xl:href="http://snomed.info/id/2088005" xl:show="new">2088005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e0b0f953-4549-4424-9200-bb836e2757ff">page blue G-90 stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_79010b8b-f31d-46e1-91b4-c22d5239080c">
                                <link xl:href="http://snomed.info/id/2088005" xl:show="new">C-22898</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dac4b708-8180-4679-98f4-71a8905038ea">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0056270" xl:show="new">C0056270</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_685b2338-f8d6-49fd-86c2-2b2556ee767a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ab67a06e-7f00-463e-9671-74468c7419b2">
                                <link xl:href="http://snomed.info/id/48540004" xl:show="new">48540004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7327206e-2ac0-40af-8e74-77877a8f6bb1">patent blue V sodium salt stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6bb7d4d5-a91d-4f46-8177-aef25c27be5b">
                                <link xl:href="http://snomed.info/id/48540004" xl:show="new">C-22885</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5f2da9b-d756-43c4-bd02-6d63717cc3a2">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0116465" xl:show="new">C0116465</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f412048a-cc75-492a-90a4-93c0a2ffe98e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99ee6cb0-fb08-439d-a378-236290f7820b">
                                <link xl:href="http://snomed.info/id/255808002" xl:show="new">255808002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_48635bd1-2111-4015-a77d-3a74e14f6129">periodic acid Schiff stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0da571e7-3bc0-4ecf-b79f-061be5e45971">
                                <link xl:href="http://snomed.info/id/255808002" xl:show="new">C-2281F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_773a751e-5d68-443c-966f-4aaa9a6f2379">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440048" xl:show="new">C0440048</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0578ecdf-6942-48ed-b222-39efba649585">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9332ea10-30fa-494a-a2b7-95726f5abeaa">
                                <link xl:href="http://snomed.info/id/333111009" xl:show="new">333111009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d2e1da46-2ab3-4c8c-9a71-ff683a64ee14">permethrin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb13e5cc-d152-4c39-9ae7-b459e056a81e">
                                <link xl:href="http://snomed.info/id/333111009" xl:show="new">R-F748A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cdb914b1-5dff-4bcc-811c-d8228d9ab7cc">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1446695" xl:show="new">C1446695</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6246b6b6-bfe2-48df-9271-21773bf058c2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7ae9151-c0ec-4e14-84a5-22bb6162f0a8">
                                <link xl:href="http://snomed.info/id/406974003" xl:show="new">406974003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d7c8d538-3e42-4e61-af04-ecc2e60f18db">peroxidase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8062cc5-edda-4d4a-a8be-07b1c545908b">
                                <link xl:href="http://snomed.info/id/406974003" xl:show="new">C-2285E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a78aef0a-44b8-4e58-94c3-e6dbceae8cf7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318719" xl:show="new">C1318719</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47564183-a12e-4a50-938b-4596966074ba">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dbdc98f7-58fe-4c93-aecc-1c76d9c24d73">
                                <link xl:href="http://snomed.info/id/71957009" xl:show="new">71957009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_85a8cc87-b6cf-4b70-911d-e938a47d1f31">phloxin B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_307a9958-a4b5-4106-9bbc-04a7ec03884a">
                                <link xl:href="http://snomed.info/id/71957009" xl:show="new">C-22922</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4fdc40ec-ac9d-44b7-81ad-d450b908d568">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0031567" xl:show="new">C0031567</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4a1fa46-ce06-471a-9685-9866feefbd87">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04d9e9eb-0b71-4df1-a843-cceca35a1426">
                                <link xl:href="http://snomed.info/id/406967008" xl:show="new">406967008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6e9c4863-0775-4aa1-b240-04a5426c2a6d">phosphotungstic acid-hematoxylin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0726370-6776-4e8b-9a3d-41f035de04c6">
                                <link xl:href="http://snomed.info/id/406967008" xl:show="new">C-2284E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3537f81-d2cc-4575-a73a-622ea8f72e62">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0491956" xl:show="new">C0491956</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e2141fd-1dc2-4768-965b-6ea08d83760e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fbb8cb66-263b-44b8-bd2a-dbc58f2a71db">
                                <link xl:href="http://snomed.info/id/65730007" xl:show="new">65730007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_68a0fa0b-ad58-41d0-986b-f02fdcf7f7e9">ponceau 3R stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4045e98e-d58b-4b0e-9d15-93653b053c11">
                                <link xl:href="http://snomed.info/id/65730007" xl:show="new">C-22829</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_02b4fc67-fe77-4554-8203-78325c21b8ab">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0071718" xl:show="new">C0071718</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6fc59e0-410a-4d7d-9010-4456cbfb66c7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_72758cc2-c87e-4d12-bdf3-eb3a7ddfd5ce">
                                <link xl:href="http://snomed.info/id/89856006" xl:show="new">89856006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a9b81fbe-8366-436c-b9d6-aedf50db09b5">ponceau S stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b0793d31-3320-4f3f-bdb5-71fc02d24d19">
                                <link xl:href="http://snomed.info/id/89856006" xl:show="new">C-22868</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_61b0103e-6bab-4b19-8394-8e0a4b8f8f26">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0071720" xl:show="new">C0071720</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2adcf0ad-399b-4979-81d0-c18d51964e57">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c97ad9c4-7384-40ee-b63b-ac1310e6631f">
                                <link xl:href="http://snomed.info/id/70520000" xl:show="new">70520000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f2075b86-1cfa-4883-8131-39d1fa23f461">ponceau xylidine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bcb92052-b190-4ae1-9d4d-02ce4491125a">
                                <link xl:href="http://snomed.info/id/70520000" xl:show="new">C-22828</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_34695b46-ba00-44ff-9d8b-cee5c531e1aa">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0950345" xl:show="new">C0950345</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d8e9c351-cb97-424b-bd6d-5a13a0a0d829">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_71828f55-8f4f-4bc5-8903-a455f6a27640">
                                <link xl:href="http://snomed.info/id/89577003" xl:show="new">89577003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3c18e992-d88a-45a0-9abf-9448f7adf23b">pontamine sky blue 5BX stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3518b869-0741-4910-98b5-23d824a08074">
                                <link xl:href="http://snomed.info/id/89577003" xl:show="new">C-22855</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_28f0c923-b8e3-4f39-8443-3ffe40720ce9">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303874" xl:show="new">C0303874</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91a9d40e-aa3b-41fa-b3f3-48dea6ae122f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1aa5b8b5-042d-4019-a95a-fdbebcd1cee2">
                                <link xl:href="http://snomed.info/id/80305003" xl:show="new">80305003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_806eb7d5-b0fb-4537-8e67-4676ffb52bd6">pontamine sky blue 6BX stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_16d6e49c-35c8-43f3-accb-e0620020b927">
                                <link xl:href="http://snomed.info/id/80305003" xl:show="new">C-22856</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e06b240b-14a5-4dc4-b74d-f1ac70716fa6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303875" xl:show="new">C0303875</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7def7a87-b47c-4094-b8fb-c00d431f8af3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb29bdd1-fa3f-4c26-84b8-973d05e29f16">
                                <link xl:href="http://snomed.info/id/34763001" xl:show="new">34763001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_66820bdf-447b-45d0-9626-719c7d31214d">potassium hydroxide stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0834aea-50c9-49a4-a91b-c01050157951">
                                <link xl:href="http://snomed.info/id/34763001" xl:show="new">C-10330</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_23302fc7-f3b9-411f-b2fd-fad090d612c3">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0071767" xl:show="new">C0071767</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5df05b6f-694a-49d9-8e7f-b55bf7d63d89">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_45cdf9d2-55eb-4d20-8e5e-d5f06f5de8e5">
                                <link xl:href="http://snomed.info/id/24900003" xl:show="new">24900003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cf508e53-3e4d-448f-9037-9d2235a830d5">procion brilliant blue MRS stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8023006-2bec-4636-82d3-4c337186acb0">
                                <link xl:href="http://snomed.info/id/24900003" xl:show="new">C-22956</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_45be9c62-5bd8-41f2-ba17-4a19d2c1f8aa">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303914" xl:show="new">C0303914</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ed8112a-3c56-4d45-9ead-b3962877eb4a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7adfca43-5d19-4616-b33e-ac4321005400">
                                <link xl:href="http://snomed.info/id/406993001" xl:show="new">406993001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_324350a7-a633-4ca1-ad7d-63c6461400bd">protargol S stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c40c25f-d204-4b58-bfe1-0fe7a8aec3dc">
                                <link xl:href="http://snomed.info/id/406993001" xl:show="new">C-2288A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08ced0ef-ec26-407b-9b04-6b6e41b5c618">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0492806" xl:show="new">C0492806</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_36d5658a-8103-499d-bf14-05cace6c3467">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df98567a-4964-4b6f-8d1e-16e3f51b61f6">
                                <link xl:href="http://snomed.info/id/406452004" xl:show="new">406452004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_455a28b8-2fdf-4128-9a3b-f9fdb80c5457">Prussian blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4701963-f23b-4331-a88d-269539b897c9">
                                <link xl:href="http://snomed.info/id/406452004" xl:show="new">C-13036</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5adbd7cc-9d50-4c45-93b8-6c4496fcd726">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0060234" xl:show="new">C0060234</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1462f87a-4a43-455c-bc32-8bc6d6fcd389">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5acf53fb-fc1b-4e6b-ba71-1fd30133adce">
                                <link xl:href="http://snomed.info/id/406968003" xl:show="new">406968003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b0941d0a-0c80-4cbb-84f6-d9b9ab5c2a62">quinacrine fluorescent stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66df337c-85da-4807-81e6-8a3aa331dcfe">
                                <link xl:href="http://snomed.info/id/406968003" xl:show="new">C-2284F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f963ad4d-0a34-409a-8b82-0122caa70a2c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318715" xl:show="new">C1318715</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_18c6241c-f6d5-4e55-b344-2db93de844e4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba564484-d091-4739-bee1-d03bd55592e1">
                                <link xl:href="http://snomed.info/id/406977005" xl:show="new">406977005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_57f959d5-8120-4c5e-9f94-006dbb3bb2ea">rhodamine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53a81773-7a7c-40d8-80ab-9a623040df59">
                                <link xl:href="http://snomed.info/id/406977005" xl:show="new">C-2286A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64044afb-6b35-4106-86d6-ac1a634d5e48">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0600322" xl:show="new">C0600322</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8afebba0-3fd3-4f67-b588-aa2529de3e57">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1123c9c1-dc47-4890-a8d7-4f2c8c9ab221">
                                <link xl:href="http://snomed.info/id/255810000" xl:show="new">255810000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_107a1342-180d-4d27-a1f6-ee215636bd05">Romanowsky stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1fde5d6c-3608-41fe-9795-596b5ef708af">
                                <link xl:href="http://snomed.info/id/255810000" xl:show="new">C-2282A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b702f66-0148-44a2-af2c-fd3aebfd7070">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440055" xl:show="new">C0440055</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1883d2a6-9b49-47f2-94a8-0987825539d9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57a7b0f1-bc06-41c9-90cc-776fecf40677">
                                <link xl:href="http://snomed.info/id/408742009" xl:show="new">408742009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_838df9c9-b4b4-42e7-b6ca-4397d7cee183">rose bengal stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_530ad494-6ae1-4f47-9dce-3102a6c82f8d">
                                <link xl:href="http://snomed.info/id/408742009" xl:show="new">R-10223</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eab65313-5dba-4754-8c20-83873f94ed8d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0035857" xl:show="new">C0035857</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0532545b-99af-4c44-b492-694e20de6c28">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_41096053-97d4-44b8-9f5d-c749e01af63e">
                                <link xl:href="http://snomed.info/id/15529003" xl:show="new">15529003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_965f50c3-2ae4-4e13-bcc3-aeca0cbcdbe1">rosolic acid sodium salt stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c7502bb-0f36-49ed-9b16-92ea8a77e0d3">
                                <link xl:href="http://snomed.info/id/15529003" xl:show="new">C-22908</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a6ea681-7e85-4837-bee5-c6b1d33a8601">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303898" xl:show="new">C0303898</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_31a5eeab-e226-4f63-93a5-f929beae0cf9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c5e1aaf-9ff1-4a23-b66b-af88a48a3628">
                                <link xl:href="http://snomed.info/id/38271009" xl:show="new">38271009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1caed189-4856-4915-9db4-dfb7c40f9fee">saffron stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_530cbe7b-c08c-4f65-873c-8b09708e6ca2">
                                <link xl:href="http://snomed.info/id/38271009" xl:show="new">C-22964</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e522a88-e7b3-41dd-b134-88061c81aa7b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0162753" xl:show="new">C0162753</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6047f9cc-7716-4da2-b3d2-dcdd0500cd73">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6bb62f3c-7c41-4726-9ce5-42e021aeac53">
                                <link xl:href="http://snomed.info/id/406988004" xl:show="new">406988004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_73f20668-fc21-4581-8da2-6680ccc15de8">safranin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9b0e0145-4a12-4cb4-b799-715ae3057da7">
                                <link xl:href="http://snomed.info/id/406988004" xl:show="new">F-61DA5</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9115f60-2e08-4d33-84a3-d1161e8e9c26">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0073949" xl:show="new">C0073949</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc4c7185-cc9c-483a-a4c4-89b7eb1c0d91">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0257a5e-7355-4694-bb7d-212e4d028fce">
                                <link xl:href="http://snomed.info/id/406985001" xl:show="new">406985001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aa2b7ac8-549b-4f83-8b1d-f6a9b9e9fe44">silver nitrate stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a20ef378-47f1-42c7-b35f-424a7dd36c18">
                                <link xl:href="http://snomed.info/id/406985001" xl:show="new">C-2287A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2bf32239-3774-43d1-be55-8b05daec04f1">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1321600" xl:show="new">C1321600</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb70c7be-baca-4c14-84ff-e7e5656fa231">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60155214-8e04-46a9-88e8-3d50ddf9bbfa">
                                <link xl:href="http://snomed.info/id/406951002" xl:show="new">406951002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fc2478fc-ea6e-4e73-a39e-c018ad3d2a39">silver stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e006f44c-7e40-4943-aa85-109334e1e073">
                                <link xl:href="http://snomed.info/id/406951002" xl:show="new">C-22836</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2135fe6b-282b-4fbc-8cd1-04834eb46a34">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318876" xl:show="new">C1318876</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b61c28b5-05ee-4675-97f2-49c7a74c0997">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_251967cd-6bc8-4bf6-8aaf-bd070d84de64">
                                <link xl:href="http://snomed.info/id/51567006" xl:show="new">51567006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d9535be3-0add-4aa6-a921-fd645069b693">sirius red F3B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a4beb4c-ee6e-4a38-b05e-39c5a4373e68">
                                <link xl:href="http://snomed.info/id/51567006" xl:show="new">C-22874</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b1ac9eb-748f-456e-bd68-c281e50f63f3">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0071047" xl:show="new">C0071047</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2effdf8-4d08-4178-ae42-80b83c3efa0e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8b0ef78d-7689-4d07-84d9-263cd95c2ad7">
                                <link xl:href="http://snomed.info/id/43549000" xl:show="new">43549000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_eb37b529-a68c-44ea-b100-33c0dc6e1f92">solochrome azurine (BS) stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b5bbc14-01d9-4116-b75b-4398dfc6bc0b">
                                <link xl:href="http://snomed.info/id/43549000" xl:show="new">C-22912</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4894e79-532b-4236-a7aa-f7f0a5bb0818">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303899" xl:show="new">C0303899</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aceb4000-e03f-473e-bf3f-6ddb34611d0f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b4edc154-72f6-4b5f-b0d7-fae800baef66">
                                <link xl:href="http://snomed.info/id/11201005" xl:show="new">11201005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d9251733-b1f3-48c4-b79d-f870d5a2a644">solochrome black 6B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38cf2437-761f-43bd-a345-6fca469435b7">
                                <link xl:href="http://snomed.info/id/11201005" xl:show="new">C-22821</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d8356d8-42d1-4938-880a-2da184fb94e5">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303864" xl:show="new">C0303864</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_074911d1-56e9-44e7-84e1-8781524f8615">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50ba12b3-877f-4266-853e-1724e1a20dfe">
                                <link xl:href="http://snomed.info/id/25091000" xl:show="new">25091000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_60436980-3228-4a68-8808-f16b47d41483">solochrome cyanine R stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0fb8194-355b-4afb-8e8c-1a62668116b0">
                                <link xl:href="http://snomed.info/id/25091000" xl:show="new">C-22909</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ff053c3-8320-4e52-b214-4bc208ad532c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0074807" xl:show="new">C0074807</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f5032da-fdc1-4982-9ba8-5e41dcfe9309">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f717e3b-ff1e-4e55-8bbc-bb898d8ae48c">
                                <link xl:href="http://snomed.info/id/38902009" xl:show="new">38902009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c7cecd57-e1d7-48d1-8f6c-15ef3893214b">solochrome dark blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ca8883e7-e0ee-4a89-a1de-ecd8c05c5eb6">
                                <link xl:href="http://snomed.info/id/38902009" xl:show="new">C-22825</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ec80c73-0c8f-4353-98e4-39d389db9995">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0054495" xl:show="new">C0054495</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cefdf91e-1b4c-415e-82ce-ca5885f47fda">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a14c218-39b3-482f-8e72-6b7919385749">
                                <link xl:href="http://snomed.info/id/64991008" xl:show="new">64991008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_12cc7a4c-641d-45e7-9dd0-84045ea72592">soluble berlin blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6840ee64-3d01-4d0e-9ca9-6fb5f9213ce8">
                                <link xl:href="http://snomed.info/id/64991008" xl:show="new">C-22975</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a6b731a-f1df-4df1-9935-670a6799f5a7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303919" xl:show="new">C0303919</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1eb021c5-8a4c-4df1-9a70-e2d4338731ef">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85e8e313-05f0-4187-8a60-78d2db45182d">
                                <link xl:href="http://snomed.info/id/11645004" xl:show="new">11645004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_677af3ad-e79a-4ad6-bd8d-30b1020acdad">spirit soluble aniline blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d77e5797-498d-4301-bb7e-6aff8dbc177f">
                                <link xl:href="http://snomed.info/id/11645004" xl:show="new">C-22906</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b60e814-c504-468d-9a24-08eda1d0846d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1260876" xl:show="new">C1260876</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7c3c57d2-4e57-4a5c-8e16-fdd8289fc6a5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_801532b1-9c6a-4d4b-8e98-ec71ac22c561">
                                <link xl:href="http://snomed.info/id/83600004" xl:show="new">83600004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8bd510a2-d313-40c4-978c-c356fa184c40">spirit soluble eosin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e3c8930-0aa5-4ac8-b31d-154fe5224af7">
                                <link xl:href="http://snomed.info/id/83600004" xl:show="new">C-22920</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5638f9f8-7082-4007-8c2e-af419193bdb0">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303903" xl:show="new">C0303903</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_432ba577-ea00-43c5-8486-daed9970b1b3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12d978b9-8be0-4efa-b8e4-38a8dfc7b3b7">
                                <link xl:href="http://snomed.info/id/255811001" xl:show="new">255811001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_488c265c-03ba-4b28-8ed8-ca96ea8a0ebc">spore stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0bc64c0-013b-48a3-b301-be079d081a4f">
                                <link xl:href="http://snomed.info/id/255811001" xl:show="new">C-2282B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dfe4f8b6-1533-46d8-bfa9-e162598b7a3b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440049" xl:show="new">C0440049</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2eb70ce-8f39-417e-b7bf-d0d9e94cce0b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5485cbcf-af97-492a-b2ca-0b7d19af4611">
                                <link xl:href="http://snomed.info/id/314900004" xl:show="new">314900004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_48db0217-a834-46d8-9949-3d118f664d92">Sudan stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8e92db2-abee-499c-8cab-52c210c7ddc2">
                                <link xl:href="http://snomed.info/id/314900004" xl:show="new">C-2282D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8d179ca-6db8-4b1d-be04-51fbca344cfc">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1282434" xl:show="new">C1282434</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64bf7635-fb0b-4717-9b98-e413f3f3ae1a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e204def-4d87-4cd3-a951-6f60a4c6cade">
                                <link xl:href="http://snomed.info/id/22968009" xl:show="new">22968009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e98f0de3-993b-44ec-a7ee-ffda75bc1aff">sunset yellow FCF stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a505e566-5028-46f1-9837-fa8c40007ade">
                                <link xl:href="http://snomed.info/id/22968009" xl:show="new">C-22827</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f190ab54-8c77-4451-9e9e-ed200d40502b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0060120" xl:show="new">C0060120</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_242762ba-6b35-445b-bedf-2fd85a8d9ca3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46a40411-ff1e-4200-b914-af774f9f9e76">
                                <link xl:href="http://snomed.info/id/21592006" xl:show="new">21592006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_544e6bff-b087-4c5c-994c-35e80554edde">tartrazine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8951cca8-b940-4d1e-98e8-27b857a4fa27">
                                <link xl:href="http://snomed.info/id/21592006" xl:show="new">C-22844</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0ec27ea-224f-4261-901e-069028cd0910">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0039329" xl:show="new">C0039329</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_915b4488-7938-4c1d-a2e6-af4121f10ee0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6242ae64-8950-40bb-b51f-3edbe4ccb74d">
                                <link xl:href="http://snomed.info/id/406975002" xl:show="new">406975002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_51c799e0-e038-41d3-8a57-631be83f5618">terminal deoxynucleotidyl transferase stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a5758c3-4cbd-47f7-b8dc-26132c714d7d">
                                <link xl:href="http://snomed.info/id/406975002" xl:show="new">C-2285F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e66259dd-797e-4251-af55-a6fc3da2bd13">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0687124" xl:show="new">C0687124</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de07dfae-6dd7-4aa3-9af1-93d496deec70">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4049ebfa-7586-4424-bb8d-488de34f9fca">
                                <link xl:href="http://snomed.info/id/406995008" xl:show="new">406995008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_febf66e1-f915-465e-89b2-259902c44a60">thioflavine S stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fcc628f5-c026-48b8-b31a-5803268b3523">
                                <link xl:href="http://snomed.info/id/406995008" xl:show="new">C-2288D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ecdc72eb-c12c-4077-b795-59cdcafe1459">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0952039" xl:show="new">C0952039</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f420c85c-0a3b-4418-b1e4-b99457f1aabb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_384679f9-cfe8-4b8b-875d-f67c8bb0e981">
                                <link xl:href="http://snomed.info/id/61068006" xl:show="new">61068006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8aea939a-8647-4b30-adba-f2b6e85af1c2">thioflavine T stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86964b40-60a0-4898-8b23-9b93b2493f22">
                                <link xl:href="http://snomed.info/id/61068006" xl:show="new">C-22926</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a277e59d-c084-4754-be5c-91a8e762d0fe">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0076466" xl:show="new">C0076466</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9af96543-34f9-4f33-ac2b-18c1241f3552">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87da32f3-898c-4ac0-9693-84596c9a0a0e">
                                <link xl:href="http://snomed.info/id/406969006" xl:show="new">406969006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6ab0edc8-a9ec-43af-96db-3d8582d42847">thionin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e0f0546-83b0-4688-a1a0-a80ade5333c5">
                                <link xl:href="http://snomed.info/id/406969006" xl:show="new">C-22850</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6a315a55-604e-4d1d-952c-3b6a74cadc99">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0076494" xl:show="new">C0076494</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_758fc694-cb71-4fec-8839-dab070b80cfa">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dde95290-06eb-4725-8d02-f8a143a99694">
                                <link xl:href="http://snomed.info/id/12001002" xl:show="new">12001002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_19805450-209d-4d5f-a2c8-c75c3c64cba4">thionine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9829152-2f4a-416b-a6bb-9ad7b7d61a98">
                                <link xl:href="http://snomed.info/id/12001002" xl:show="new">C-22943</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c40c5a0-1972-4e74-b44e-c4cd2a1e1d23">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0076494" xl:show="new">C0076494</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f7da279-51c9-4aa3-9040-6c9c3816c419">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_94bca6a2-55ba-4d00-9f1a-8e20608cd3c7">
                                <link xl:href="http://snomed.info/id/84217005" xl:show="new">84217005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_81e730ea-ea20-408f-88b4-1bebf4753c98">titan yellow stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cbdf872e-c8ef-40e6-9097-4c020ef04b7b">
                                <link xl:href="http://snomed.info/id/84217005" xl:show="new">C-22845</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a21f835-b388-456e-8511-8366d1462b50">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0076731" xl:show="new">C0076731</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e419092d-f943-44ea-8736-13c9a59a17d3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ea52f7b-6a71-4943-bc80-a9669f9a0b70">
                                <link xl:href="http://snomed.info/id/406989007" xl:show="new">406989007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_223bea2d-cdb3-47b9-ba30-3b29a95ea0be">trichrome stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6345ca0e-9c7f-425f-b056-1f2cf555e64d">
                                <link xl:href="http://snomed.info/id/406989007" xl:show="new">C-2287D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ac18664-67bb-487b-ae88-934e8e802e7a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0077066" xl:show="new">C0077066</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b712bd9-c8ed-4f9d-ae5c-d739dd3b9cf5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b7ff9a39-fc9d-456b-b554-939f14248eda">
                                <link xl:href="http://snomed.info/id/35094004" xl:show="new">35094004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bad29742-bba6-4aa5-b9d8-c052895d6356">tropaeolin O stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_67a99383-da43-4daa-987c-ad82b73a3285">
                                <link xl:href="http://snomed.info/id/35094004" xl:show="new">C-22815</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f194f4b-f2c8-4204-8d29-9bca08c48bc1">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303863" xl:show="new">C0303863</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_343fe611-527c-4e94-9a68-948d5b938c9d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_975c0f03-cf98-4e8e-b983-709092c43dbc">
                                <link xl:href="http://snomed.info/id/53511009" xl:show="new">53511009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1048ac5e-fb87-43d1-8d35-d5d716ad65c9">tropaeolin OO stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6380d57a-517c-4f6e-a2ce-f5d1ff092340">
                                <link xl:href="http://snomed.info/id/53511009" xl:show="new">C-22812</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_676303fe-7e83-4135-bdbd-53082f29b07c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0077384" xl:show="new">C0077384</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_468541f6-e691-4e1c-9fb1-51e4b91c84d4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14a4d28b-b725-40aa-ad4c-a27c3c426578">
                                <link xl:href="http://snomed.info/id/60441008" xl:show="new">60441008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b4610f4c-c916-4382-9c12-e22e8ac2770b">trypan blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a030c549-1b14-42c0-b15f-8f351d64eea5">
                                <link xl:href="http://snomed.info/id/60441008" xl:show="new">C-22853</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_74dc0c4a-5090-4a29-ae16-4fa846f82166">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0041213" xl:show="new">C0041213</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d56821b0-a1f8-4f20-b6e5-f1aa29904ba5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8a546bbb-9d2f-44f1-a8cc-998d1bdc0b07">
                                <link xl:href="http://snomed.info/id/406957003" xl:show="new">406957003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7a791245-42cd-4fcc-bc3e-d3d083ad2c75">Van Gieson stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc64f44a-9538-4bc2-9f5f-7f3603bd70ab">
                                <link xl:href="http://snomed.info/id/406957003" xl:show="new">C-2283E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_01ad054d-8547-4dc0-8d8a-e4ad221d5a84">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0491963" xl:show="new">C0491963</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a732816-ede8-4daf-b8c2-43f91d3c2333">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf62212d-6d40-4728-ac60-1631e06c0994">
                                <link xl:href="http://snomed.info/id/406992006" xl:show="new">406992006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_afb46018-3960-42cb-9881-9b0d6dbc9ce6">verhoeff's hematoxylin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e635ce12-b3da-462c-afc9-ee4d54f00713">
                                <link xl:href="http://snomed.info/id/406992006" xl:show="new">C-22880</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c838ff06-573b-47fe-a574-7ed503cb1ec2">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1319311" xl:show="new">C1319311</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc2e3519-1aa6-4b67-ad72-abf9fdb2626d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_556d297c-d3f4-4b60-95c7-bd146007f6d8">
                                <link xl:href="http://snomed.info/id/20230008" xl:show="new">20230008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e2d1903a-3499-475b-a003-048937fac038">vital new red stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9bc3234e-982e-40c1-a204-9948e88a0e2f">
                                <link xl:href="http://snomed.info/id/20230008" xl:show="new">C-22858</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09326848-fc92-4c65-abac-828d995efc9f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303876" xl:show="new">C0303876</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f568289e-ead9-46e4-827e-3fdc7edba642">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dcbfda94-8ffe-4d5b-a01a-6e02d462dfcb">
                                <link xl:href="http://snomed.info/id/88625006" xl:show="new">88625006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_99edfcad-5a98-4a5a-8465-38f11e33c482">water soluble aniline blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fda40f26-0d06-418a-bfd2-cbcfe206f005">
                                <link xl:href="http://snomed.info/id/88625006" xl:show="new">C-22904</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c53680d7-b24a-4c7b-af81-9cc9c0a1c8ab">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1321796" xl:show="new">C1321796</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7707deb9-4f63-43de-bd76-52e2c994408c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_72b03b4a-5bf8-4e44-9844-29cb01050a0a">
                                <link xl:href="http://snomed.info/id/58755002" xl:show="new">58755002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d19f6ecc-16b3-4d93-8b3f-ca65be4f2160">water soluble anthracene brown stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ced7b76-17db-4831-a05e-33e68c7803c8">
                                <link xl:href="http://snomed.info/id/58755002" xl:show="new">C-22954</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ace14b36-b587-4b54-9816-2e6861486b90">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303912" xl:show="new">C0303912</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9470c34-423f-4ffe-8d01-43bf0cc1aa67">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d214dbe-4b62-40c8-961a-c63d7b97a4ec">
                                <link xl:href="http://snomed.info/id/12119009" xl:show="new">12119009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bac7b5f0-7257-4441-a733-8d814b400dce">water soluble nigrosine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b209e42d-406f-466c-a37e-8bb0b527c8da">
                                <link xl:href="http://snomed.info/id/12119009" xl:show="new">C-22933</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ecdcdd99-cf73-47d5-8d84-f6f1dd29b0b7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303909" xl:show="new">C0303909</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d800df9e-558a-4b23-ac58-c1967d86a1db">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7e23611-2258-498a-93d6-26248b423c0e">
                                <link xl:href="http://snomed.info/id/60739006" xl:show="new">60739006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_58367ff9-cdde-4b15-9438-8adbdcac6344">waxoline blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6848d9da-77ac-45da-b8c7-4ab4ebee37fb">
                                <link xl:href="http://snomed.info/id/60739006" xl:show="new">C-22957</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8faa5bfb-33c8-4125-8966-42b19eb120eb">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303915" xl:show="new">C0303915</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44bca1ca-a577-45ff-883f-dc5df7e7b1ab">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ec1512d-2672-4cc2-92a8-af09f4511f5f">
                                <link xl:href="http://snomed.info/id/409549005" xl:show="new">409549005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9142d1b4-38cb-4958-a731-f57da993c0f8">wayson stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_74ecd932-08dd-4b84-b56f-d8c2d3e34641">
                                <link xl:href="http://snomed.info/id/409549005" xl:show="new">F-61E5A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d5257148-314d-4300-a445-060b67ed35a1">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1443889" xl:show="new">C1443889</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a2feb79-cb31-49a0-8309-5fd7efb66b99">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e411eb18-2456-4559-84cf-d1544004bf99">
                                <link xl:href="http://snomed.info/id/373682001" xl:show="new">373682001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_02823b6d-b2f4-407b-98da-15e7e4eb23fe">wright stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_023eb176-0c7e-4a9e-83be-9bbd09406c53">
                                <link xl:href="http://snomed.info/id/373682001" xl:show="new">F-619B7</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e1f8a401-ca27-44e0-b6c9-c4567e064c3c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1261259" xl:show="new">C1261259</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_29ae188b-b980-4bc3-b66c-b366530d1cfe">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37f50b88-77d8-42ed-a9db-6bcae0557f4a">
                                <link xl:href="http://snomed.info/id/55831004" xl:show="new">55831004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1564d5b1-c013-49b5-a4ed-1a0a6ccdab80">xylene cyanol FF stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0625b8f7-5ac5-42b2-a269-fd866249f94a">
                                <link xl:href="http://snomed.info/id/55831004" xl:show="new">C-22888</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_837a584f-864a-4f99-bc87-c402e5c848ec">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303889" xl:show="new">C0303889</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6fc2fc40-a643-4adc-9fc6-43c1b60f14b9"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14c8f851-4238-4282-afca-9223189ec2ea">
                                <link xl:href="http://snomed.info/id/255813003" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">255813003</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dca880f3-7016-4203-a527-62ba865f7a72"><emphasis role="bold"><emphasis role="strikethrough">Ziehl-Neelsen stain</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc9a2996-d2a5-46f1-a7f5-374a91a870fe">
                                <link xl:href="http://snomed.info/id/255813003" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C-2282C</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac2c2bcd-02e1-4e57-b0a5-74078edc0ca4">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0440051" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0440051</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22d9605a-a632-4930-9876-759dc7d2a20f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0da2a47e-09a3-4ee4-8fb3-0150e6a4b17b">
                                <link xl:href="http://snomed.info/id/29252006" xl:show="new">29252006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0488262a-ef52-4e1a-83f7-75611a00e026">acridine orange stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9ea6767-5c7d-4edc-a4e0-b8f80bb53f8d">
                                <link xl:href="http://snomed.info/id/29252006" xl:show="new">C-22A08</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b101d1bf-7d91-4353-91dd-b8e9629efdcd">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0001185" xl:show="new">C0001185</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e94aaaa-df5e-4a72-8433-4b4a733ca478">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f938d828-cb0c-43b8-8b71-3686f4983daf">
                                <link xl:href="http://snomed.info/id/17693003" xl:show="new">17693003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1c8f1376-ad4f-4577-b386-35b86c964627">acriflavine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d76f5e0b-eaa1-4bd1-bae3-b860916aeff8">
                                <link xl:href="http://snomed.info/id/17693003" xl:show="new">C-22A07</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53c71a56-26eb-421b-8845-4def0d040461">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0001187" xl:show="new">C0001187</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ea2e81c-62b1-425e-b2b8-b5f705a16143">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e7f9f7d-e841-430a-b07b-72990708bdee">
                                <link xl:href="http://snomed.info/id/84656005" xl:show="new">84656005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7cccf9b5-8cbe-4af5-b8c9-4848b4442828">atebrin FS stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_033a6f96-045b-4e25-a296-7b4b7a72bb01">
                                <link xl:href="http://snomed.info/id/84656005" xl:show="new">C-22A03</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_465010a2-74cf-42eb-bc6c-fc5cef23dc18">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303922" xl:show="new">C0303922</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c26100d0-fcbe-463e-8aa7-84114d41b5f4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20658803-8b35-423b-b9f7-4598d5237094">
                                <link xl:href="http://snomed.info/id/73251007" xl:show="new">73251007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bc7a6eff-2729-4fd8-b2ed-3dac0866f273">auramine G stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1a21f88-2e0e-46bf-8d3a-36fccfbf64b6">
                                <link xl:href="http://snomed.info/id/73251007" xl:show="new">C-22A02</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96bd3089-e974-45f9-93f4-da483c13b21d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303921" xl:show="new">C0303921</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_005ae9cb-86f2-4e90-8653-17865c7a38a0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91b96136-689f-482f-897f-f2d7e9a535e2">
                                <link xl:href="http://snomed.info/id/81397005" xl:show="new">81397005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f0ba1250-512e-4148-9a6e-5823ac228f5c">auramine O stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9816f97e-0868-4e60-976c-a1ca535e1565">
                                <link xl:href="http://snomed.info/id/81397005" xl:show="new">C-22A01</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76701990-feb3-4606-af35-5bc131badedc">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0878260" xl:show="new">C0878260</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a151c10-b9f5-4106-83fd-8fc1c515780e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09eebfab-0c42-49d1-899c-c26c8cbaf33c">
                                <link xl:href="http://snomed.info/id/49687009" xl:show="new">49687009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8fbd6deb-4547-45b5-91bb-889d5874c37e">coriphosphine stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d3c4846-679c-4e39-a4f0-9b0162154a30">
                                <link xl:href="http://snomed.info/id/49687009" xl:show="new">C-22A11</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2d82d24-a206-4c50-9d38-0e9f9ae123b2">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0056341" xl:show="new">C0056341</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7f1b99b-4153-442b-9b65-298ba6badf62">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2d5b9e0-29ed-49e2-b023-cd9fc149b450">
                                <link xl:href="http://snomed.info/id/85596006" xl:show="new">85596006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e44fac60-f764-4786-aa8f-be2005c876a4">fluorescein stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2f1e0aa-ec80-4203-898f-a6c94755b8fa">
                                <link xl:href="http://snomed.info/id/85596006" xl:show="new">C-22A05</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a5553322-068e-4246-a064-c969b398c8db">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0060520" xl:show="new">C0060520</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82fdaa55-743c-4272-a3b3-7f440b5e080f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66c9bbf4-8cda-489d-9fc8-3aaec22df3f7">
                                <link xl:href="http://snomed.info/id/108880002" xl:show="new">108880002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_13e8f71e-e055-425a-94e2-dd7f3f0419a1">fluorexon stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40e93557-1981-4ab9-91af-4546c00ffb01">
                                <link xl:href="http://snomed.info/id/108880002" xl:show="new">C-22AA1</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd845812-c152-44d9-86c6-cde30b155053">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0060549" xl:show="new">C0060549</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e0d303e-ffb7-4138-ac8e-2d3344959aca">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b9dc9eab-d542-4148-aa7f-83f6fb04224a">
                                <link xl:href="http://snomed.info/id/27671009" xl:show="new">27671009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2fc710c2-c7d6-4116-a99f-93925331560a">rhodamine B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04d92c3d-983f-47d9-a368-2621858f0b3e">
                                <link xl:href="http://snomed.info/id/27671009" xl:show="new">C-22A04</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8920d433-bd6e-4d55-ba65-0196a50fe955">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0073194" xl:show="new">C0073194</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_75c93699-3574-4ece-af5a-0d6714ed3910">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad7282f8-af64-41d1-b997-84214080fd5c">
                                <link xl:href="http://snomed.info/id/25351006" xl:show="new">25351006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_21ef3076-0eab-4e9a-8392-3da1bd904bab">Fluorescein sodium stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8950664d-1ba7-40a2-a6b4-51588f405418">
                                <link xl:href="http://snomed.info/id/25351006" xl:show="new">C-22A06</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c6d286f6-be21-4c21-90b5-5abb749a3f89">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0147866" xl:show="new">C0147866</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_95794b89-cf92-4bb2-8f18-8329e11609c6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1c65690-f667-44db-b981-f82ac5cdf57d">
                                <link xl:href="http://snomed.info/id/36572009" xl:show="new">36572009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a9c3d80e-75b6-4ccb-9df8-ca89b61daa69">Sudan black B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85cfd779-c48e-49b0-936f-5c151789ff1b">
                                <link xl:href="http://snomed.info/id/36572009" xl:show="new">C-22864</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df905537-5834-4d1a-99b4-ffe2eb6ef0bb">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0075489" xl:show="new">C0075489</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_edebb7da-f752-495c-aabc-5fb9a02c391f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dfba58f6-a3ae-48e1-948b-49be17d11381">
                                <link xl:href="http://snomed.info/id/310805002" xl:show="new">310805002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6cba0bea-7d23-4220-ade9-8e8c38ade013">Sudan black stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eaa167db-aae8-40c2-8aac-2d6046f2d82d">
                                <link xl:href="http://snomed.info/id/310805002" xl:show="new">C-2282E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91a1c6da-58e8-406b-a8c7-56fd06ac2a0c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0588374" xl:show="new">C0588374</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1f733e45-2d8f-45fc-9ac3-735cd6f9a21e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ffdf222-ee37-4ac6-bc7d-8635ea22ea2e">
                                <link xl:href="http://snomed.info/id/10740006" xl:show="new">10740006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c2773e93-748f-4459-925b-02f3bf3fa239">Sudan blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a496bff-8639-4063-b476-cf6dd7002519">
                                <link xl:href="http://snomed.info/id/10740006" xl:show="new">C-22958</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08dc6788-febb-492f-a924-caf1e0fbc3f6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0075490" xl:show="new">C0075490</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_52fb7496-1476-4154-bc97-de1ea091b595">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_25414c35-a0bc-4331-8532-3e37d656d28c">
                                <link xl:href="http://snomed.info/id/12030009" xl:show="new">12030009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_614d8a52-85b0-4302-af61-c28bc0a68ada">Sudan II stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b4f8c36e-0bbe-4388-b0f1-fc7119b65760">
                                <link xl:href="http://snomed.info/id/12030009" xl:show="new">C-22807</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d6b772d3-f8e0-4b40-8200-ebc70fb142fe">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0075492" xl:show="new">C0075492</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3bbe4260-c9ac-493d-8d05-68b5ae81e10b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44d09f17-3dd4-49e7-873a-4f5ee2db5338">
                                <link xl:href="http://snomed.info/id/39777001" xl:show="new">39777001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d9ec714f-9ec8-4f49-af1b-3694ff587aeb">Sudan III stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b38e401-04be-44e0-b9f8-93d61adfb1f9">
                                <link xl:href="http://snomed.info/id/39777001" xl:show="new">C-22861</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2442a566-7217-4a76-8edb-3de5efbd98df">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0075491" xl:show="new">C0075491</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c040cf76-4649-42a2-8d93-aa497a6f2c74">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89299f2f-a47e-4d56-bef5-3fdf44be9bd7">
                                <link xl:href="http://snomed.info/id/69133007" xl:show="new">69133007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4c129334-14fa-441e-b6fa-ee483f32797b">Sudan IV stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f90d2975-32c8-4836-8b64-4f3cf93c911a">
                                <link xl:href="http://snomed.info/id/69133007" xl:show="new">C-22862</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eaf3afd8-1a3e-40fa-9573-87c379058304">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0074127" xl:show="new">C0074127</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91c3d504-495e-4063-95bc-1c1b5ea1c449">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0cc151aa-21b6-4a99-8cda-951235822062">
                                <link xl:href="http://snomed.info/id/76925007" xl:show="new">76925007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c240729d-c3b4-477e-b81c-a0f5fbbb56f7">alkali blue 5B (4B) stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac0dca22-1a3a-4673-b059-2296ef31309f">
                                <link xl:href="http://snomed.info/id/76925007" xl:show="new">C-22903</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7483ad4e-fac5-4cc9-84a8-6d649f8f628c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303894" xl:show="new">C0303894</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c83e195f-cbb8-422b-9977-6410f2ba36d7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e1913b64-fbf8-4897-817b-61a74ce8a004">
                                <link xl:href="http://snomed.info/id/63929007" xl:show="new">63929007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_64076a7c-0b19-4486-9e1a-b28f6d3e1040">alkali blue 6B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0480a15-d3f0-4540-be66-206e0112aeeb">
                                <link xl:href="http://snomed.info/id/63929007" xl:show="new">C-22905</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d9fd68d-e5e3-473d-8fa9-43d99ecbb078">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303895" xl:show="new">C0303895</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fba0335a-e206-4a3b-b1ab-c71f8e8f7f0f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_480b109e-fdd8-4bce-97b9-740f21c606f6">
                                <link xl:href="http://snomed.info/id/34128002" xl:show="new">34128002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6386a831-b55c-4b50-9cfc-7015c1e7cf33">chrome azurol S stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0b5b6a5-5d76-4359-a52b-96d159b685f2">
                                <link xl:href="http://snomed.info/id/34128002" xl:show="new">C-22911</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70039d1a-d73d-4163-8b8b-4893a83472d2">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0055614" xl:show="new">C0055614</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_447b4373-b6d0-426c-a32f-a23788acc12f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e46f0382-8e3c-4b85-888b-d6d4984eb9f6">
                                <link xl:href="http://snomed.info/id/17172002" xl:show="new">17172002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_841aeb0a-280d-4edf-a914-bef9f0265002">dibromofluorescein stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dff3e3a0-30b3-4695-8acf-fe2409ae9b73">
                                <link xl:href="http://snomed.info/id/17172002" xl:show="new">C-22918</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1cd78b0-8864-4c90-bc8e-8e0f83ca4e68">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303901" xl:show="new">C0303901</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_378802a0-d2eb-4931-b2b5-cf50a7940746">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f5ff9c04-382c-43e8-b66a-912ec7118a85">
                                <link xl:href="http://snomed.info/id/65445001" xl:show="new">65445001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_14c093b5-a5d9-4a8e-aed1-03d022207748">ethyl violet stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89ef65ec-5997-4912-8ffd-8763326fe935">
                                <link xl:href="http://snomed.info/id/65445001" xl:show="new">C-22897</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_976142af-e60f-40b7-bfb5-52fe9001ead0">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0059784" xl:show="new">C0059784</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5fd6ee9b-edcf-452a-bf5d-6bd011efd495">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_133fbd6d-4508-4bbc-a78a-9d677a9b9c74">
                                <link xl:href="http://snomed.info/id/22021002" xl:show="new">22021002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0e4dfd17-151f-49e6-aa1f-943200d28642">methyl green stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7dbf1ff-634a-498e-96ba-c8d9924b6bf9">
                                <link xl:href="http://snomed.info/id/22021002" xl:show="new">C-22896</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8fb3f15-31aa-4559-8a85-79102967032c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0025701" xl:show="new">C0025701</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ac10d65-7f85-4ee3-b778-7a4538539bb6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6d9ee7a-1a06-4d70-83e7-1677bbe79440">
                                <link xl:href="http://snomed.info/id/15896008" xl:show="new">15896008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c02ed753-ef2c-4410-87ff-796ac6d89352">methyl violet 2B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a278a7ae-1fcd-4e56-9d63-8af03da64f2a">
                                <link xl:href="http://snomed.info/id/15896008" xl:show="new">C-22892</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9f835a7b-52a3-4c33-87cc-a1f0b48984fa">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303890" xl:show="new">C0303890</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_29479746-d184-4fed-950a-56fc54f2493a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2bf7705b-158b-4172-a9cc-5996468ca6c6">
                                <link xl:href="http://snomed.info/id/14544006" xl:show="new">14544006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_737cc028-ae74-4f25-89d3-840b52511c86">methyl violet 6B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e18a64d-ad79-4eb1-94ee-70811f2618a2">
                                <link xl:href="http://snomed.info/id/14544006" xl:show="new">C-22894</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cc8a42b-d27f-45f2-9796-689521018cee">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303891" xl:show="new">C0303891</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac7c0ff7-9a23-43a3-9bb2-4e66c2ce3207">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cde6620a-1e9d-489d-939f-cb2ed9289f93">
                                <link xl:href="http://snomed.info/id/76001002" xl:show="new">76001002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c7316f7b-d865-4416-8616-68c4db766347">pyronine B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd264a10-e9fa-4738-a952-cdebd0b12ba3">
                                <link xl:href="http://snomed.info/id/76001002" xl:show="new">C-22916</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_39c5006a-fd75-40e8-b9d5-94ff33c4cff9">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0072769" xl:show="new">C0072769</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1b555137-5a14-4953-b4dc-1494ff15b72e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58b22f3f-c8fc-440f-b51f-14f3eb049a9b">
                                <link xl:href="http://snomed.info/id/43106008" xl:show="new">43106008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_55a1b14a-94fd-4a4c-9194-298b429d6bd1">pyronine G stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7aad5767-430a-45b0-a586-6f05ba51e9af">
                                <link xl:href="http://snomed.info/id/43106008" xl:show="new">C-22915</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d97e0da4-59d6-4381-8919-b3d9a8636323">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0034316" xl:show="new">C0034316</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44928e72-387f-47a8-90bc-5e1f17873044">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c21cde35-99fe-4a2e-9e13-67459582bf71">
                                <link xl:href="http://snomed.info/id/29522004" xl:show="new">29522004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b0cb656e-cb15-4f47-b837-fc0c9947e468">toluidine blue stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c4a74ab-9b73-425f-b8a3-15eeafe9f764">
                                <link xl:href="http://snomed.info/id/29522004" xl:show="new">C-22951</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_17b8098f-8b2c-4d34-af55-fbe601ba2253">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0040380" xl:show="new">C0040380</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2cbba4c-4ba1-4ed7-a885-44c20b5db971">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_255dbc32-5006-487a-9e5c-a8f1968072c5">
                                <link xl:href="http://snomed.info/id/82682000" xl:show="new">82682000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8477ddc0-1651-48ed-9eb3-704c28a32539">victoria blue 4R stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_005c8d95-c0c1-4cc3-867e-3a332fac7481">
                                <link xl:href="http://snomed.info/id/82682000" xl:show="new">C-22895</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d93dbb1f-90c9-4574-8bdc-ccc676e6a16f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0078233" xl:show="new">C0078233</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8ac7fba5-422c-4c88-b5ca-9aef59c78f3b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb33b797-a7d9-481d-9d20-e793f67875d7">
                                <link xl:href="http://snomed.info/id/22749001" xl:show="new">22749001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0bc1b89d-fb5c-45dc-8ef7-771f757d50aa">victoria blue B stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86e7d921-1812-424d-a962-f065382791c9">
                                <link xl:href="http://snomed.info/id/22749001" xl:show="new">C-22913</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a0dc7856-69c9-4da0-9506-713fdc2141e0">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0078234" xl:show="new">C0078234</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d31b0e8-1fd0-4db9-8f7a-9989cfad11d2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c6971b0-0c0a-4eca-90c5-33bb61dd3e9b">
                                <link xl:href="http://snomed.info/id/36879007" xl:show="new">36879007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_93e46ec6-d6ff-499a-bf6a-df4192f5b884">water soluble eosin stain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb507dec-63c5-417f-aa6a-b9708cafdda5">
                                <link xl:href="http://snomed.info/id/36879007" xl:show="new">C-22919</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_75339817-bda2-4a8a-a18e-cd174c04c680">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0303902" xl:show="new">C0303902</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="CID 8122" status="3" xml:id="sect_CID_8122">
            <title>Microscopy Illuminator and Sensor Color</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_adcb5f70-e9aa-4139-b86d-66e8c67dcdea">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8122.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-8122-MicroscopyIlluminatorandSensorColor.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-8122-MicroscopyIlluminatorandSensorColor.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.899.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_fb723524-595e-4f78-80e3-cd2ccb4db554">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_82f25fc2-6c71-45ee-afc2-1aae6c9ec231">
                            <emphasis role="bold"><emphasis role="strikethrough">20100824</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_b50a18e7-70cd-4863-9d2e-9ad4a0ebbb9e">
                            <emphasis role="bold">1.2.840.10008.6.1.899</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8122" rules="all" xml:id="table_CID_8122">
                <caption>Microscopy Illuminator and Sensor Color</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b62f2956-144e-46b7-992c-bc50d1d68cb1">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44ffbeb0-3815-4024-af36-0612bb960edc">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99e53f2d-a930-430a-aa1b-795cc3dc15c7">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_542452e0-02ba-41fd-bf20-941a550fa2ad">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7774406-1c7c-4147-9936-983beca544aa">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa087895-bb3c-4d0e-b5f8-e69d2dc7001e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_23e8b1e1-918f-4cd4-bcba-119fcf52cc0d">
                                <link xl:href="http://snomed.info/id/414298005" xl:show="new">414298005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1cac0770-5d05-403d-b3d0-6d2aed109266">Full Spectrum</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ebdee86f-1cdd-4cdf-9c9e-cf76595577c0">
                                <link xl:href="http://snomed.info/id/414298005" xl:show="new">R-102C0</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6bf3ecad-9a9c-4e04-990b-743d33463b7b">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1532530" xl:show="new">C1532530</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/134223000" xl:show="new"><emphasis role="bold"><emphasis role="underline">134223000</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Narrow</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/134223000" xl:show="new"><emphasis role="bold"><emphasis role="underline">R-41727</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0333164" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0333164</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8db8694-796a-458b-ae45-2a50b156d428">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4c3372f-020d-407b-8a91-e24f8713b672">
                                <link xl:href="http://snomed.info/id/414497003" xl:show="new">414497003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7497dc75-1675-461b-8c17-dddd21a5adee">Infrared</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0718da00-9043-40b7-a819-c989fbd4b885">
                                <link xl:href="http://snomed.info/id/414497003" xl:show="new">R-102BE</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc997f6c-308b-4346-b4eb-511a0efc4719">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1532326" xl:show="new">C1532326</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4454c484-563a-486c-b028-0b8c3f4a28aa">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12857038-73ce-471d-8f10-11560bead70a">
                                <link xl:href="http://snomed.info/id/371240000" xl:show="new">371240000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f0abc920-cd6b-41f3-9f32-60ad8e3fce7d">Red</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70220e76-f271-4aee-b7a1-3b1149a2762f">
                                <link xl:href="http://snomed.info/id/371240000" xl:show="new">G-A11A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dd3dc585-5bc5-49a9-9a8e-161e21ae905b">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1260956" xl:show="new">C1260956</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6a8a31dc-df56-46ee-ad69-5865336fee70">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4a0a6d6-75d6-44c6-a644-f11fcfa9d0ac">
                                <link xl:href="http://snomed.info/id/371246006" xl:show="new">371246006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5d409789-554a-43fd-8b55-b55774318b99">Green</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f69fb494-29cb-4ae7-9425-d4bfd0f4def7">
                                <link xl:href="http://snomed.info/id/371246006" xl:show="new">G-A11E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6186548-0b7e-4de7-99f9-adf2c9842956">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0332583" xl:show="new">C0332583</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a5c52289-f828-45ed-af9a-b3f317555a77">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aec992da-fedf-47a7-a7b2-372cd2790501">
                                <link xl:href="http://snomed.info/id/405738005" xl:show="new">405738005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0080918b-b75c-4d4d-8533-28114af83d2a">Blue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a2c2fde4-31e1-483d-a0d7-1fd00b646931">
                                <link xl:href="http://snomed.info/id/405738005" xl:show="new">G-A12F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a054d7e3-e9b7-4951-ae4a-9f8da37d3453">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1260957" xl:show="new">C1260957</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92d0c203-e139-4cff-8902-0087f412ee84">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c7c43edb-9d75-47f9-a059-fa30e4a254b7">
                                <link xl:href="http://snomed.info/id/415770004" xl:show="new">415770004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b681ae88-6ae0-4968-a86b-706f2068fd6e">Ultraviolet</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a9be629-1547-4ae2-92d6-d8079161a504">
                                <link xl:href="http://snomed.info/id/415770004" xl:show="new">R-102BF</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2d439a7-e106-4128-92be-fdeaf3a829df">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1532472" xl:show="new">C1532472</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 8130" status="3" xml:id="sect_CID_8130">
            <title>Staining Protocols</title>
            <para xml:id="para_66245ba4-72e8-4be1-ac62-e84c4ee3a7b0">This Context Group is intended for use in the Scheduled Protocol Code Sequence (0040,0008) and the Performed Protocol Code Sequence (0040,0260) attributes for an automated slide stainer. When so used, an Item with value <link xl:href="http://snomed.info/id/127790008" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">(127790008, SCT, "Staining")</emphasis></emphasis></link>
                <link xl:href="http://snomed.info/id/703857004" xl:show="new"><emphasis role="bold"><emphasis role="underline">(703857004, SCT, "Staining")</emphasis></emphasis></link> will also include a Protocol Context Sequence (0040,0440) <emphasis role="bold"><emphasis role="strikethrough">using</emphasis><emphasis role="underline">which may use</emphasis></emphasis>
                <xref linkend="sect_TID_8003" xrefstyle="select: labelnumber quotedtitle"/> to identify the specific stain substance<emphasis role="bold"><emphasis role="underline"> or specify a more specific stain method</emphasis></emphasis>.</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c392bb33-7455-400e-8300-8d4127ee1cf6">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8130.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-8130-StainingProtocols.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-8130-StainingProtocols.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.944.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_3eeaa64b-7985-4dde-8a9a-a664bacdd6c8">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_417d41f6-3fcb-4e9f-ad5a-9456ce58f464">
                            <emphasis role="bold"><emphasis role="strikethrough">20111028</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_840992fe-783d-4cdc-b12c-6f9bba6f1bfa">
                            <emphasis role="bold">1.2.840.10008.6.1.944</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8130" rules="all" xml:id="table_CID_8130">
                <caption>Staining Protocols</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_681b7c2c-8971-4021-a091-9080d013daf0">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6958e90-b53b-4a3e-8321-ac2d2fca3e38">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_67e8586a-d59b-441a-8101-41a1d0d88718">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_121842c8-5763-4350-b0b0-625dafdb701d">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1cf3d7a-de55-48d5-94d2-99165c2af185">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_888a7867-2c4e-476e-a344-d78b03158b41">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9bff0085-edca-4ab7-9197-40d1da07a999">
                                <link xl:href="http://snomed.info/id/127790008" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">127790008</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/703857004" xl:show="new"><emphasis role="bold"><emphasis role="underline">703857004</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cc817ba4-16f9-43ca-8b1a-a6a04b1e4711">Staining</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3352b079-5a52-488e-8c84-e50cf75966b8">
                                <link xl:href="http://snomed.info/id/127790008" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">P3-00003</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/703857004" xl:show="new"><emphasis role="bold"><emphasis role="underline">R-FBDF9</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2bd03d2-50a2-496c-9a62-62950314f57b">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0487602" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0487602</emphasis></emphasis></link>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C3839348" xl:show="new"><emphasis role="bold"><emphasis role="underline">C3839348</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_39e0df0c-a110-4b0a-a70c-c0cc65c32228">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f608176-2a20-43d0-b0a2-a670cbe2886d">
                                <link xl:href="http://snomed.info/id/104210008" xl:show="new">104210008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bbc00318-3572-4af5-8fad-ba0de11070dd">Hematoxylin and eosin stain method</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2adf4fc7-ecf3-4c69-83ef-3de139fb41e5">
                                <link xl:href="http://snomed.info/id/104210008" xl:show="new">P3-50495</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66347e1e-dd99-4eef-934e-1f50daa1feb4">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0523207" xl:show="new">C0523207</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/708056006" xl:show="new"><emphasis role="bold"><emphasis role="underline">708056006</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Acid fast stain technique</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/708056006" xl:show="new"><emphasis role="bold"><emphasis role="underline">R-FF04E</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0200974" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0200974</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/406979008" xl:show="new"><emphasis role="bold"><emphasis role="underline">406979008</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Ziehl-Neelsen stain method</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/406979008" xl:show="new"><emphasis role="bold"><emphasis role="underline">P3-00068</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1318721" xl:show="new"><emphasis role="bold"><emphasis role="underline">C1318721</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <para><emphasis role="bold"><emphasis role="underline">Previously, <link xl:href="http://snomed.info/id/127790008" xl:show="new">(127790008, SCT, "Staining method (procedure)")</link> was used with the meaning "Staining", but has been replaced by <link xl:href="http://snomed.info/id/703857004" xl:show="new">(703857004, SCT, "Staining technique (qualifier value)")</link>.</emphasis></emphasis></para>
            </note>
        </section>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">DICOM PS3.16 as follows for reference unchanged:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="CID 8113" status="3" xml:id="sect_CID_8113">
            <title>Specimen Preparation Steps</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_219c1929-6783-4d1d-a86a-fbe2b0262780">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8113.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_8113.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_8113.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1051.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_3e7d95cc-a35d-430b-b2f9-2ae194b66d97">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_352ca7f8-d58a-48d2-b0ab-ac519d32fd6b">
                            <emphasis role="bold">20080626</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5bfd8923-5afb-4930-b648-284b31a88121">
                            <emphasis role="bold">1.2.840.10008.6.1.1051</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8113" rules="all" xml:id="table_CID_8113">
                <caption>Specimen Preparation Steps</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1f033ae8-337b-413e-a3a7-c72e39035441">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f17433a-5ac6-447c-a190-8990589c7c74">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_427f7a12-8947-4dfd-ae5e-26b21c052db9">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c50abb3-8b1f-49b1-82eb-16bf33a8ef02">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f2e65bd-c67f-415a-8e09-1c80348127ff">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4509499e-01f9-44db-a1a8-5891d96f0ed9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ca5032e-8f33-41e0-8161-6cf95d32a161">
                                <link xl:href="http://snomed.info/id/433455005" xl:show="new">433455005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_22bd6b75-9c54-4b3a-8417-56bce95209a5">Specimen microwave heating</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b0f26de1-1c79-4661-9e85-be1422ca6ea0">
                                <link xl:href="http://snomed.info/id/433455005" xl:show="new">P3-40005</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_458be293-3d60-4c0d-9505-86da9868f44a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2317595" xl:show="new">C2317595</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc26a503-843d-4556-8ed8-890853670475">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb1d0281-bfc2-41ce-8aca-39ad38ce8244">
                                <link xl:href="http://snomed.info/id/433457002" xl:show="new">433457002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_eb61b070-edc8-4aa7-a6c4-5c1fb083fa4e">Specimen steam heating</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e0bb04b-35a8-4be0-94d6-b44b6f4e3dbe">
                                <link xl:href="http://snomed.info/id/433457002" xl:show="new">P3-40009</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8e8b5a3-e531-4019-b2dc-d912bbd7fad9">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2316565" xl:show="new">C2316565</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c33e0098-1936-4a40-a1f2-c16212eaa14a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0e68f59e-e2f9-49bd-b4bd-262133c39d97">
                                <link xl:href="http://snomed.info/id/433456006" xl:show="new">433456006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6c2420ef-ce6b-4888-b417-d3c024229082">Protease digestion of tissue specimen</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4e7c4a5-4cc6-4020-a5f8-c301f130ec83">
                                <link xl:href="http://snomed.info/id/433456006" xl:show="new">P3-40006</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_75781526-a84a-40e6-b51a-783bf872d025">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2316566" xl:show="new">C2316566</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19f85480-f320-408f-9597-7f2ae6b576fb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_97a89b39-1fb7-47ce-b566-6685199e5bb5">
                                <link xl:href="http://snomed.info/id/433470006" xl:show="new">433470006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_13a576c9-0679-4b18-931e-8d9109c34211">Specimen dehydration</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5816d940-1bd2-4502-870b-69d01f21e74f">
                                <link xl:href="http://snomed.info/id/433470006" xl:show="new">P3-4000B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99b4804a-fa69-4f4d-a567-131313d36df6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2317330" xl:show="new">C2317330</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_00444d45-63e5-4278-bea0-0bf5a5f2c265">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9549e1a-0e33-4885-9227-05faa91df0f9">
                                <link xl:href="http://snomed.info/id/27872000" xl:show="new">27872000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c14a100a-f97c-47bd-bbbe-13c4a2cd5c3c">Specimen freezing</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dfd9feba-d77a-4b93-961c-8c49df3b7954">
                                <link xl:href="http://snomed.info/id/27872000" xl:show="new">P3-05050</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_253a9a41-bf83-4ead-ba00-a814fa3c938e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0200367" xl:show="new">C0200367</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_555faa71-2bde-4801-aab2-e9800be3e3f2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_303c34ac-1072-4c88-8008-cbf40958a144">
                                <link xl:href="http://snomed.info/id/433452008" xl:show="new">433452008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e0cf8d29-e49d-44bc-9bac-fe8befbe7185">Specimen clearing</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_359a1502-5cf3-4c43-a1c1-b61f1b207aba">
                                <link xl:href="http://snomed.info/id/433452008" xl:show="new">P3-40003</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf284088-5d63-4e7c-a71e-d502900ec05a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2316366" xl:show="new">C2316366</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="CID 8114" status="3" xml:id="sect_CID_8114">
            <title>Specimen Fixatives</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f5f7fb39-d40c-4c3f-95db-7da5e6a575a1">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8114.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_8114.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_8114.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1052.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_40231843-492d-460e-86e9-6f5a837bc555">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a2771a38-c479-453b-ab4c-6cb72f79d64f">
                            <emphasis role="bold">20190124</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_8edeee68-16ce-41ba-bc7a-0a84f51eebe5">
                            <emphasis role="bold">1.2.840.10008.6.1.1052</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8114" rules="all" xml:id="table_CID_8114">
                <caption>Specimen Fixatives</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04a6c796-f771-41b2-8b99-20409356c1f0">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8b9c492-1bc9-4b71-925e-da085d53280f">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb901d0a-14a8-488f-8889-94e3571906b9">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_41552d50-ab7a-4c49-8515-6de46d701449">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ea5f7d0-e65a-44b8-88b8-50fd714b4b4c">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e435e4d3-7e4c-4a10-ad63-e988d59c9960">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_edc139fc-6651-4631-95cc-f0d702d44927">
                                <link xl:href="http://snomed.info/id/434162003" xl:show="new">434162003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4ae13cec-af76-4540-9fb7-ff8528b68593">Neutral Buffered Formalin</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b83d051-6174-4e83-8a77-52c62825c5fc">
                                <link xl:href="http://snomed.info/id/434162003" xl:show="new">C-2141C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2066da99-afce-4ff2-9bac-2b5bc07f9987">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0492002" xl:show="new">C0492002</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89956982-f6f6-4c5a-8759-180cae39be55">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1fddd0bb-6971-4886-a43a-08db01bd2f10">
                                <link xl:href="http://snomed.info/id/433474002" xl:show="new">433474002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5321f41e-237f-4f51-a05e-e5615cd9a75d">Bouin's fluid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d32197c5-af01-4f31-9d8a-9750c9ab288d">
                                <link xl:href="http://snomed.info/id/433474002" xl:show="new">F-62235</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53ec8f15-547c-4800-bff9-0a1b8842184b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0053963" xl:show="new">C0053963</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_15f55fae-d17c-4129-9597-e2b20d2a56f7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a78ed5c-e1b6-4bdf-beb0-fb027b29421a">
                                <link xl:href="http://snomed.info/id/431510009" xl:show="new">431510009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ba96d6cb-3241-4693-b11a-0ee511e8de0b">Formalin</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_05e10beb-1589-443e-aaf2-b13e4d6549ab">
                                <link xl:href="http://snomed.info/id/431510009" xl:show="new">C-2141B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_536a0596-c230-4194-91a9-31d17dc4a320">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0949307" xl:show="new">C0949307</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_629033ed-c767-42dc-9bad-4936c609d6dc">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_caea43c8-6d51-4583-af3d-d530d376d7e1">
                                <link xl:href="http://snomed.info/id/433338005" xl:show="new">433338005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9d778d54-049e-487f-b06b-f0d73823f7b7">Carnoy's fluid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4bdb0c5a-8338-40c1-9400-159978be976a">
                                <link xl:href="http://snomed.info/id/433338005" xl:show="new">F-62231</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b4c9717b-aa3d-4ebb-bf7b-4fef9524405c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2317379" xl:show="new">C2317379</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62c2e71f-978c-4f64-8d73-83f72dfe56de">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1cef7707-cbf5-4b0f-8cb8-bed1bf9b9e25">
                                <link xl:href="http://snomed.info/id/434295000" xl:show="new">434295000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ac435e3b-ac1f-437f-9587-9b98f35853c2">Formol sublimate</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_457097ed-e018-4d48-a290-c711457b7688">
                                <link xl:href="http://snomed.info/id/434295000" xl:show="new">F-62238</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8890d7f2-74d1-405f-a8dc-268b0e5aa4c9">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0621539" xl:show="new">C0621539</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a5df0d60-eda3-4665-b2a2-d940f043fa07">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1204559-1b74-4059-aa84-07023dbe5d7d">
                                <link xl:href="http://snomed.info/id/433471005" xl:show="new">433471005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7435ca08-3a5b-4b63-b78a-785ace47fa81">Helly's fluid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e70c868e-778f-42ef-8648-1e96982aa53b">
                                <link xl:href="http://snomed.info/id/433471005" xl:show="new">F-62233</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3ab4fcfd-c604-4634-872a-29505583737f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2317380" xl:show="new">C2317380</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0feb0bd8-ca8f-4d76-b66d-a8292e6232c4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66a73885-3f4f-4c4a-a0c2-711e870da1e5">
                                <link xl:href="http://snomed.info/id/430028007" xl:show="new">430028007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_17681877-7b67-4a70-adf7-86ec1a496e15">Michel's medium</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5c0052f-0e94-4f52-9862-158325ce7f5d">
                                <link xl:href="http://snomed.info/id/430028007" xl:show="new">F-6220F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4582072-50fb-4636-a6c9-c5e5ff44af20">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1550080" xl:show="new">C1550080</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56ee661b-fd62-453e-9f94-986cd2520cbb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9630a4d1-28d6-4e33-91b3-70eff8fe32f8">
                                <link xl:href="http://snomed.info/id/433473008" xl:show="new">433473008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_13f70424-7653-44a6-9b5f-3a9cb9553381">Zenker's fluid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e52faef-602e-4c64-bb7a-2b079d238471">
                                <link xl:href="http://snomed.info/id/433473008" xl:show="new">F-62234</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ef11e01-450d-4491-bf6c-62ecbdc26869">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2317478" xl:show="new">C2317478</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b4ffd823-b2f7-459a-8bce-7bd2ccfa8e21">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9fa30f5e-b1d2-4b9f-879a-c7aab58e1d4d">
                                <link xl:href="http://snomed.info/id/52836003" xl:show="new">52836003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6626e766-84cf-49c5-ae50-904cc36352b3">Paraformaldehyde</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de6c3950-82c9-46ee-9cc6-12772d801e6a">
                                <link xl:href="http://snomed.info/id/52836003" xl:show="new">C-21403</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ffd4b8b8-1bd4-40b3-b20b-46ce75837efe">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0070066" xl:show="new">C0070066</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6889935-449d-4578-b46b-4eb49d4a98e3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8030fd4a-b235-466b-96b3-9542a2e90e27">
                                <link xl:href="http://snomed.info/id/2869004" xl:show="new">2869004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a0ad0c1d-d5f4-4ee2-a746-de2469098637">Acetic acid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47e99e4a-1625-44f4-b4f6-017576b8f6e0">
                                <link xl:href="http://snomed.info/id/2869004" xl:show="new">C-21624</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d123e79c-06d2-4497-a3a4-0d4a771b28ae">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0000983" xl:show="new">C0000983</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63545499-9e08-4982-91e0-6f55ccf2c55f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac0841f0-3e61-48ba-b64d-2e3c57f39310">
                                <link xl:href="http://snomed.info/id/259153006" xl:show="new">259153006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ce33c656-0a66-49ad-b31c-26a8483f4ef3">Chloroform</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1241c717-0c2e-46b4-a771-1b7a2a998c2d">
                                <link xl:href="http://snomed.info/id/259153006" xl:show="new">C-20830</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d140bdb-6362-494e-80d7-941a469d3335">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0008238" xl:show="new">C0008238</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c91cddab-1abe-478b-9a70-fad2dcdf8d5b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b8fa2dc-c814-40f6-8831-83632957c3a2">
                                <link xl:href="http://snomed.info/id/430821002" xl:show="new">430821002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d1d9d2ab-b572-4335-a731-ce2402dfa85a">Chromium trioxide</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54336e9f-35a3-4dcc-8ac3-1989cdef685f">
                                <link xl:href="http://snomed.info/id/430821002" xl:show="new">C-12916</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d81880b2-bfcb-4473-8dc3-7e95d8cdb96d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0055630" xl:show="new">C0055630</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83fa7ce9-eb2e-4843-8b49-f9e14267c79e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40d5c07f-2fda-434f-919e-c3ebc264c523">
                                <link xl:href="http://snomed.info/id/419442005" xl:show="new">419442005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_be090b86-48cd-4d9e-ac61-e4607851304c">Ethanol</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d5fa7b7-1e1d-4cd9-9edb-f662e9bf7c13">
                                <link xl:href="http://snomed.info/id/419442005" xl:show="new">C-21047</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ee18e23-fad2-49f6-8d2a-7e4e2f91443a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0001962" xl:show="new">C0001962</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c21976f0-9cd0-48ad-b407-ca19d3d1f5cd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb68683a-257a-43cd-8b08-e164631b6df0">
                                <link xl:href="http://snomed.info/id/111095003" xl:show="new">111095003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6ccd8781-5004-4cfb-9135-bf2cbeb86d00">Formaldehyde</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f437611e-890e-4f98-bb36-6ea6e379080f">
                                <link xl:href="http://snomed.info/id/111095003" xl:show="new">C-21402</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e70f27d5-ddb4-4b42-9eb3-3591330b82d3">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0016564" xl:show="new">C0016564</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_41c3ece1-3d38-4971-a6d6-e5f961a623e1">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9682bc3c-f061-47a6-86e8-5313403d4958">
                                <link xl:href="http://snomed.info/id/11496005" xl:show="new">11496005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dde2c9e9-4811-48a5-b71b-543a94dacdee">Mercuric chloride</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_32f17ffd-3abd-4174-afa6-1f7c5942932d">
                                <link xl:href="http://snomed.info/id/11496005" xl:show="new">C-13321</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_30d03541-f34c-4071-ba25-a0dca9d7e09a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0025417" xl:show="new">C0025417</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57a6a821-a9a6-4d2b-955a-9cc3004ccba9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_81191421-3b62-4dc7-bccd-039fd5b68d23">
                                <link xl:href="http://snomed.info/id/259221006" xl:show="new">259221006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9a2255b7-83c9-4c8e-b785-26c4ec844dac">Methanol</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_803aae05-7087-42ec-a408-81785c9b474e">
                                <link xl:href="http://snomed.info/id/259221006" xl:show="new">C-2102B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3b8c519-dc8b-47b0-bd84-91cf31f9daee">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0001963" xl:show="new">C0001963</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1547935d-7c7c-4d8d-bd60-ee4dadb61eb1">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50dfe8db-bb49-4380-97f6-3448ecee1809">
                                <link xl:href="http://snomed.info/id/13931001" xl:show="new">13931001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2df75783-da1c-40e1-960a-bf0f57c6f202">Osmium tetroxide</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d45d0c1a-c4e2-48a7-aed1-7a7735746ad4">
                                <link xl:href="http://snomed.info/id/13931001" xl:show="new">C-15211</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38b77ffb-e3d1-4356-a4d7-4585624c6f03">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0029385" xl:show="new">C0029385</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_69444fe8-2e39-4220-b4d6-9741bb6e328f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d4888ca-1931-447c-a0fa-0530a35c8eaf">
                                <link xl:href="http://snomed.info/id/24215009" xl:show="new">24215009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a9d90fcb-f59c-4c62-bbe9-c0b6fa062211">Picric acid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9eaf4f58-affe-45cb-96e8-b7bf9b73839a">
                                <link xl:href="http://snomed.info/id/24215009" xl:show="new">C-21919</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e5a0b9a-a1bc-41ee-8144-4045b122f33d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0071044" xl:show="new">C0071044</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e507000-00be-4c15-bfbc-1758dfc594d5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21a57f8f-243c-4028-9848-f87a501662f8">
                                <link xl:href="http://snomed.info/id/19893005" xl:show="new">19893005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5834575c-dac8-4817-88a5-5c6ee237e510">Potassium dichromate</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a93564fb-d265-47b1-ba06-5ea2561897ce">
                                <link xl:href="http://snomed.info/id/19893005" xl:show="new">C-13518</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb2074bb-2ac7-4098-849e-484c5edde1da">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0032829" xl:show="new">C0032829</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        <section label="CID 8115" status="3" xml:id="sect_CID_8115">
            <title>Specimen Embedding Media</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_efd01aa4-23ee-4690-bb4e-cd54c87b15a9">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8115.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_8115.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_8115.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1053.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c34cb3db-b8e1-4e9a-8bd5-83d47f14931c">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c764f76c-fae3-45d4-940f-e018d5064ea9">
                            <emphasis role="bold">20080626</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_57d2cb75-57a6-44a5-abee-ca8c6823247f">
                            <emphasis role="bold">1.2.840.10008.6.1.1053</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8115" rules="all" xml:id="table_CID_8115">
                <caption>Specimen Embedding Media</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bef038ea-046c-43ff-9a74-babefd8cc7c5">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9829b1a-2d59-4147-9a5f-060fe368b993">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_71d42b3f-c3da-40eb-81d6-949974048cbd">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6fc87174-3c19-4fe6-b2c0-cfc94ded2a57">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f18e8233-5817-4984-9799-cc36b3097345">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db02edcd-956a-4e19-993f-b72e276834cc">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_118204f6-c6ea-4800-b930-c2d153bf2e7b">
                                <link xl:href="http://snomed.info/id/311731000" xl:show="new">311731000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_26f2727c-d820-4a9e-a829-5a33329ba388">Paraffin wax</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b2527560-025b-4ec3-8717-6428a468c5bd">
                                <link xl:href="http://snomed.info/id/311731000" xl:show="new">F-616D8</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3c76218-ece4-4b31-aa84-33e31c35dfd2">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0030415" xl:show="new">C0030415</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b152f70-2036-49c2-9125-7b1bbd808c32">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_10329132-1ba2-4c22-a1a2-6f3f913cdadf">
                                <link xl:href="http://snomed.info/id/433469005" xl:show="new">433469005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0e7ef518-3c4a-4fe6-9e80-f85f19d6048c">Tissue freezing medium</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64102684-f4e9-4bfd-a456-1d1269fe6e1e">
                                <link xl:href="http://snomed.info/id/433469005" xl:show="new">F-62232</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_198cfbbe-8d7c-4095-ab3c-f47b0ad28e75">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2315537" xl:show="new">C2315537</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99788b6a-55ba-4be1-8731-2e354e2f8e56">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_640dd372-1cea-4a92-9c67-506441dfad18">
                                <link xl:href="http://snomed.info/id/61088005" xl:show="new">61088005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dd3aed71-8708-466c-8310-218b640b0534">Plastic</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_75e515e4-f8ca-4d7c-926d-f57dd5132073">
                                <link xl:href="http://snomed.info/id/61088005" xl:show="new">C-2A000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a683d97-687c-4c3a-8f10-a5ffae122056">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0032167" xl:show="new">C0032167</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef550bd7-080c-4f6d-b0b6-6059a2481fa9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c35dcec7-b67b-4840-8706-8d999148b1b5">
                                <link xl:href="http://snomed.info/id/10249006" xl:show="new">10249006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b872fa62-6d71-407d-929e-aeb64de5781e">Agar</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b5bbd732-c6f5-41d5-98f4-fbad51c93f0f">
                                <link xl:href="http://snomed.info/id/10249006" xl:show="new">C-84085</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84f4ffef-c5f8-4368-9e23-f89b343f3188">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0001771" xl:show="new">C0001771</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6fbce843-51e5-4e8f-8584-dc20c2f6ef32">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_30e15ff3-9dd2-47ee-9bbc-f019e41d6eab">
                                <link xl:href="http://snomed.info/id/65345002" xl:show="new">65345002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ae06ea05-214a-45a9-a185-6b3c9a45b089">Epoxy resin</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c91fa1d3-006c-4c30-814e-36e4e6d2e88a">
                                <link xl:href="http://snomed.info/id/65345002" xl:show="new">C-2A400</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ceb0eba-3fd5-48e6-9750-b044f69916de">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0014631" xl:show="new">C0014631</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78118a04-f915-4191-a581-55e3e8a36a96">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85f137d6-0167-41d3-8aa5-ede8bc9bd54d">
                                <link xl:href="http://snomed.info/id/261712009" xl:show="new">261712009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1ad25c86-2aa6-4d37-afd6-f134abe2c32b">Acrylic resin</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59157ff6-5267-4719-9fb3-f72217d97bf2">
                                <link xl:href="http://snomed.info/id/261712009" xl:show="new">C-100EA</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fb33b501-464b-4840-9e62-ee13333833d8">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0444831" xl:show="new">C0444831</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        

        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new terms to DICOM PS3.16:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            
            
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">
                                <emphasis role="bold">Definition</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">
                                <emphasis role="bold">Notes</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd001">ddd001</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Chromogen</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>A substance, itself without definite color, which may be transformed into a pigment.</para>
                            <para>E.g., as used to visualize a monoconal antibody to a receptor for immunohistochemistry.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>From <link xl:href="http://medical-dictionary.thefreedictionary.com/chromogen">http://medical-dictionary.thefreedictionary.com/chromogen</link></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd002">ddd002</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Reporter enzyme</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Enzyme that performs a chemical reaction that produces a color compound.</para>
                            <para>E.g., as used to visualize a monoconal antibody to a receptor for immunohistochemistry.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd003">ddd003</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Subcycle</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>A subordinate event in a sequence of subordinate events to a parent event in a sequence of events.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        
        
        
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new context group UIDs to DICOM PS3.6:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="A" status="1" xml:id="chapter_A">
            <title>Registry of DICOM Unique Identifiers (UIDs) (Normative)</title>
            <table frame="box" label="A-3" rules="all" xml:id="table_A-3">
                <caption>Context Group UID Values</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3322bcc5-7ea4-44d1-9b17-499a6a5e512c">
                                <emphasis role="bold">Context UID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_225c7fe6-91ef-424b-812b-249ecd55f194">
                                <emphasis role="bold">Context Identifier</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_25349958-e4d1-4bb0-aaa9-33d5cb03df93">
                                <emphasis role="bold">Context Group Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21c2633a-2b79-49c4-baa8-d930649479d0">
                                <emphasis role="bold">Comment</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>uuux8116</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <xref linkend="sect_CID_x8116" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_x8116" xrefstyle="select: labelnumber"/>-->
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <xref linkend="sect_CID_x8116" xrefstyle="select: title"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_x8116" xrefstyle="select: title"/>-->
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>uuux8117</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <xref linkend="sect_CID_x8117" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_x8117" xrefstyle="select: labelnumber"/>-->
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <xref linkend="sect_CID_x8117" xrefstyle="select: title"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_x8117" xrefstyle="select: title"/>-->
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>uuux8118</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <xref linkend="sect_CID_x8118" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_x8118" xrefstyle="select: labelnumber"/>-->
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <xref linkend="sect_CID_x8118" xrefstyle="select: title"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_x8118" xrefstyle="select: title"/>-->
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>uuux8119</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <xref linkend="sect_CID_x8119" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_x8119" xrefstyle="select: labelnumber"/>-->
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <xref linkend="sect_CID_x8119" xrefstyle="select: title"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_x8119" xrefstyle="select: title"/>-->
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>uuux8129</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <xref linkend="sect_CID_x8129" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_x8129" xrefstyle="select: labelnumber"/>-->
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <xref linkend="sect_CID_x8129" xrefstyle="select: title"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_x8129" xrefstyle="select: title"/>-->
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.17:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="NN.6.2" status="3" xml:id="sect_NN.6.2">
                <title>Slide</title>
                <para xml:id="para_c5f53ae1-9659-4f60-901b-b7e7e3a22b19">...</para>
                <para xml:id="para_bdde4f8f-e68a-49ce-9ede-f242c42c5b0e">The example Specimen Preparation Sequence first describes the most recent processing of the slide (staining), then goes back to show its provenance. Notice that there is no sampling process for the slide described here; the LIS did not record the step of slicing of blocks into slides.</para>
                <table frame="box" label="NN.6-4" rules="all" xml:id="table_NN.6-4">
                    <caption>Specimen Preparation Sequence for Slide</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_864bb96e-f60a-4860-9f9c-ef29ad63dd23">
                                    <emphasis role="bold">Specimen Preparation Sequence - Item #</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52419eb6-3ee5-46f2-bcc8-2afea7293c23">
                                    <emphasis role="bold">Specimen Prep. Step Content Item Sequence - Item #</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_468abab7-5489-4387-8638-f902d7d35472">
                                    <emphasis role="bold">Template / Row</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7cba060a-3dd2-4f17-9a6f-dec2ca944475">
                                    <emphasis role="bold">Value Type (0040,A040)</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93e87f41-830c-441f-b242-c2281238ee6a">
                                    <emphasis role="bold">Concept Name Code Sequence (0040,A043)</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca0727bb-1edd-4634-9073-96571fd6925f">
                                    <emphasis role="bold">Example Value</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cac5974-cbb5-41a2-a8b2-5ddd3b7d96a5">
                                    <emphasis role="bold">Comments</emphasis>
                                </para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="6">
                                <para xml:id="para_3711c0fc-7ce1-4337-8ba1-1d0cd99be43f">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f56e214-629b-4d50-83be-b761efb28bb5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9a37953-13af-4c86-a507-e592ab775f06">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55129dc9-d80a-4362-bff8-b4dd18e3e02e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b876f67a-b8ad-4749-a99d-0337d95d163a">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c540d8d-f57f-4a3e-a886-500476717982">S07-100 A</para>
                            </td>
                            <td align="left" colspan="1" rowspan="6">
                                <para xml:id="para_8e6e61fd-b905-49fd-bfc6-d1e62df17811">Part Collection in OR.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20aa8564-919a-4ecc-91a0-869fa9d3395e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_957cbdc0-2703-4ba9-a929-584552a98360">8001 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5b4d10a-549d-428e-bfc4-8d7872bdb69f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84b619d1-de3e-44fd-ac25-d1beb3ebc05c">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111724">(111724, DCM, "Issuer of Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dba6e2d-c635-4af1-af4e-0500d07846a1">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_812ca00a-a93b-4025-8532-6c15f66baa52">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16a84c9e-2b1e-439f-b325-7c1c85cca365">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29b33f75-60be-4f10-90a2-709fc0935ff9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f8efa24-fb03-4098-bcae-0574d6dacbb5">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59fb12ee-f30b-4929-910a-4239d46de219">
                                    <link xl:href="http://snomed.info/id/17636008" xl:show="new">(17636008, SCT, "Specimen collection")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb72b63b-9ccd-40f7-b7c5-dba7de79296a">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b410485e-56d4-47f1-9e5a-84f10d08be35">8001 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a270f57-b011-4f2b-a72d-ee43e9f8c135">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cb1d7cb-0991-4638-b0a9-dd948cd75b4d">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111702">(111702, DCM, "DateTime of processing")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e9ea21e-2cf4-492e-a755-1cae267f5085">200703230827</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72312b55-bfea-4974-99af-967f449434d1">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d294adf2-150e-4469-925a-30524cb40881">8001 / 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2ac2984-6c31-4a32-8b01-c4026399de26">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f80694ac-b6f9-43c8-8b3d-7e807ea18d59">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111703">(111703, DCM, "Processing step description")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc529ba4-c295-4e71-a8cc-9554ed826d52">Taken</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0088a772-2f60-44e6-b64b-09dd6f7b5287">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_caac58cc-b7c1-47ae-a388-81f9f5507bf6">8001 / 8</para>
                                <para xml:id="para_3265e4fb-d072-493b-b133-fba87d8a2490">8002 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5938e79-0440-469d-9a36-ce1a6efd4091">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5970ab00-f116-4daf-8c91-8ecb53e3fff6">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111704">(111704, DCM, "Sampling Method")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9b5288f-4df1-40c9-bbee-3235eb29ec8b">
                                    <link xl:href="http://snomed.info/id/65801008" xl:show="new">(65801008, SCT, "Excision")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="4">
                                <para xml:id="para_03fa8b59-99d5-4ca8-83f5-63166bd5eea2">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a24d43b0-a606-4a26-acf9-92a1910185c8">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f821c8e-f236-46b8-9aff-3770ac7b99ae">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77e149dd-6205-4144-a1c4-1c49bff00508">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f732c04b-444e-4c34-bd7c-de85767cbd86">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1fd1b25-fd14-47ee-a4d3-336914d8db20">S07-100 A</para>
                            </td>
                            <td align="left" colspan="1" rowspan="4">
                                <para xml:id="para_29cb7d10-c06c-492f-a5df-ea0611bc05a8">Specimen received in Pathology department</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e65db98-366b-45cb-a512-675708c2771b">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ccf6650-3e63-4823-8b76-a5e7b261d8d9">8001 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f31ec3b5-243e-4eb7-a7b0-070ba4d7de5e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b849ff9b-3824-4eb4-82cf-cc81862c8502">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111724">(111724, DCM, "Issuer of Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45b25cca-4b4e-4ed1-8f77-9075289b5908">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df3fdce7-fe8b-4751-8a77-b9891a5100af">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63863117-8d7e-47de-8135-c7bc53f3652a">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21ac811b-04d9-4990-ba6a-f13f17e1119c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_930f6f40-d0ae-4419-a058-614cebe06f6e">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eecca750-0086-4b86-a76b-9d5df8a7f9d2">
                                    <link xl:href="http://snomed.info/id/428995007" xl:show="new">(428995007, SCT, "Specimen Receiving")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4218d740-c9dc-4ffd-9fa1-a5a3d3985514">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7d4e2b2-f094-428b-93f5-cefb156b36fb">8001 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37c9ba3e-5abe-4ddc-af27-d9a26b4aa1d5">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be903ba6-fc43-4385-a50e-4c38ba8ec040">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111702">(111702, DCM, "DateTime of processing")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5762b46-664e-4670-b13b-c105d31a4477">200703230943</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="9">
                                <para xml:id="para_fdc7d8b2-24e3-4c3d-925e-f1630b622d72">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27fedfe5-bedb-48bb-9db1-045bb8808a97">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9f85827-b53d-4489-a8b1-2bd2fdc880bf">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ab05fe9-4230-4285-a9b1-f552f647de5f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aecd330a-f89f-4d27-adc1-f298ca6ffe79">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c15057e-7c57-40da-9c35-02c74d330012">S07-100 A 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="8">
                                <para xml:id="para_9cae2e80-ec3f-4181-893b-09172cfdee5e">Sampling to block</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed0fb0c2-2ac9-499a-af34-74c8d6665b19">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8a29396-5635-4055-bc2a-cf4e5ccdba22">8001 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7999c6f-cee3-4c72-8efe-a695949beb78">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ba24d48-8e7c-44e1-8edd-ab2db979c630">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111724">(111724, DCM, "Issuer of Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fee35fcd-262f-4e10-befe-ac8c6d790635">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d01f3d1-d90c-48a9-9fc4-e30d7ed3a087">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c7495a0-b075-46d8-8506-f391b1599958">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f55249d1-482b-4b5c-95f1-58fe6990d6c5">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ee5bb84-45b9-449f-8c83-5cadc06f171f">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab3329d4-e0d0-4cfc-ba01-c6e49e4dfae9">
                                    <link xl:href="http://snomed.info/id/433465004" xl:show="new">(433465004, SCT, "Sampling of tissue specimen")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fec21f80-5ce3-497c-aa87-d4420446e726">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f53590a-297f-490c-a499-4740f99e5a25">8001 / 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffa9d535-6e8a-4584-b369-431674709b2b">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c027442-130e-4fab-820e-115c092d4a84">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111703">(111703, DCM, "Processing step description")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6d26d03-d700-4a23-a91b-3d6ca2a972ed">Block Creation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b0a4a5b-e4aa-4a3b-b3d8-d3ed91cb444b">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e79117f1-6cb4-4490-8ce1-70b1d903fa8c">8001 / 8</para>
                                <para xml:id="para_e9be9b2d-e3ae-4c8d-aeb9-7cbf6e9c0d34">8002 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b4cdf9e-5b0e-4849-80b7-44fa3511cf72">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b09805d6-3822-478d-a976-f50e64562bab">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111704">(111704, DCM, "Sampling Method")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c13ee2e5-a302-40c7-84d4-c950b2219b12">
                                    <link xl:href="http://snomed.info/id/122459003" xl:show="new">(122459003, SCT, "Dissection")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db293887-cc36-4144-952d-7a9441f5d444">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f67f97d9-0c1e-4c16-941b-0a7107705084">8001 / 8</para>
                                <para xml:id="para_ac16ba92-71c1-4759-a66f-4dfbb5fbbcbd">8002 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f0d14bc-6ab5-47a2-a31c-28d652498fa8">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d38112ff-4eb0-4902-9d12-7e23a257676a">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111705">(111705, DCM, "Parent Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f9bf3e4-b102-4bc0-9a90-344a90ec1377">S07-100 A</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86370f3e-0bdd-455a-8640-ba89fe4d8e23">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be15c27c-98c7-4262-b5b8-55537694095b">8001 / 8</para>
                                <para xml:id="para_b3aab40e-225d-4c13-aaba-16dfbcede1ab">8002 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1bc3ad8-5653-4aee-bb4a-506e692863b8">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02a10084-ef4f-458a-9e9b-7f17681e2df6">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111706">(111706, DCM, "Issuer of Parent Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24e0387b-c9b9-4fb9-bc83-883ae35afcca">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89bf16d7-b19d-4c31-a70a-4a3391caf771">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b3c5f4d-43fe-4ffd-9c23-72cbe883bd33">8001 / 8</para>
                                <para xml:id="para_3de8f881-4088-454f-b9ac-74e7ace016ad">8002 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa0c28de-f1e9-4e13-85d7-29a55806b4ba">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ccd5804-8370-4354-906f-d5148b149ba4">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111707">(111707, DCM, "Parent specimen type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0748b818-4683-431b-8e57-e9e7c110caf3">
                                    <link xl:href="http://snomed.info/id/38866009" xl:show="new">(38866009, SCT, "Anatomic part")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93280c1c-b670-4b07-8a73-59db13e29941">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c92d583-725b-4f83-9ae3-852b4a941210">8001 / 8</para>
                                <para xml:id="para_2ce44d58-3b97-4e34-9fa7-49091853f071">8002 / 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01e4eabb-8b44-41c7-89eb-a7eaed1059ca">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1acc765-cbae-4fbd-a868-c0f2864bf2bf">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111709">(111709, DCM, "Location of sampling site")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eea458e7-81db-4911-9ea2-bef2b1e55e3d">Mass</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d5cd052-89a9-408e-b3cb-bae57a51804b">This is coming from the summary of blocks field in the LIS</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="6">
                                <para xml:id="para_01a54c1e-10b1-4d09-9059-fbe828629733">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08621d0c-fe41-4d20-a15b-afa414f82c25">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0aab35d2-6395-4600-b360-5e597484094a">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa4efdcf-0801-4c0c-a0ee-53f9372ec7bc">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1eb114b-e994-4ed1-9d6c-b4a40eaef4c7">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44091566-929e-4dc0-b9ff-cd2f84a4704e">S07-100 A 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="6">
                                <para xml:id="para_9ae50e74-384e-428b-ab3f-78c27ab47bb2">Block Processing</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_995a7600-22c6-45c8-9bf7-e4e9c774696e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0d3c8f6-3410-43ef-b2b7-58dd7f0210cc">8001 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9534b618-0c71-4410-a216-4c4ac2924e2e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1b7743c-e653-4cb9-b2bf-e2db17cc9357">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111724">(111724, DCM, "Issuer of Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21820955-5eab-4ffc-abd1-1e54dad81436">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4682f82-a11b-438d-b4f2-6229ce3ca563">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8621f43-fbe6-4747-a3f1-e8fd9ed050f8">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae3bbd9d-473a-48bc-bbc5-96ba80f8bab3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bd7e4c1-6e0a-4162-bb1a-d3832ff9e960">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55cb36e2-7db2-4f08-ab80-9e5df0be0943">
                                    <link xl:href="http://snomed.info/id/9265001" xl:show="new">(9265001, SCT, "Specimen Processing")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62e27498-2949-4597-89fc-61fbfa3e5420">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4f95146-6c0e-41da-a93e-cf3ef45aa5f4">8001 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71bd4e7e-0966-4877-be48-3d489ce68bf8">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f269496a-dc54-46cb-a321-70665bdaff46">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111702">(111702, DCM, "DateTime of processing")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c574592-6c62-4b1e-852d-1f18db25a11e">200703231900</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_528ded3f-ef3a-417e-923a-2c5dabbbca34">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5053bfae-66a6-4617-a3e8-3cec256bfa00">8001 / 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc1505cf-9195-405f-9491-2c2aeacd421d">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4021cc8-c472-4d44-aaf3-f367a7a7fd0c">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111703">(111703, DCM, "Processing step description")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e6a8bfc-69dd-49ab-933e-e07ca51b28a7">Standard Block Processing (Formalin)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_757aa67c-d253-434e-99de-67e5043c97b6">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23d12185-61ae-470b-90ab-aadbc05c9c24">8001 / 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8aa97d06-a890-4203-b0e5-3fceb1bc336e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a7011b8-ccdd-4abf-90ff-88d04150b553">
                                    <link xl:href="http://snomed.info/id/430864009" xl:show="new">(430864009, SCT, "Tissue Fixative")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_186011cd-4ce2-444d-bc9e-ff6d7147b051">
                                    <link xl:href="http://snomed.info/id/111095003" xl:show="new">(111095003, SCT, "Formalin")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="6">
                                <para xml:id="para_d080b277-668f-42f4-b9c5-91dc5a8902f4">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38ad8281-c88d-4704-b449-374ad630c780">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_447c93ec-fbce-4885-b499-f82eaf620ff0">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_245164f9-a350-41e6-b437-954734dcefbf">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b873be77-e4ef-4063-8527-fe86fef56680">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee94285e-3c23-42f4-922a-6bcf9aff35bd">S07-100 A 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="6">
                                <para xml:id="para_72f96072-3e98-4a64-99aa-e60d0fdbc497">Block embedding</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf4e6dd2-aef0-410e-b3e4-024ae5902e9d">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17fe59cc-5142-4a04-9b3b-8932b90e4d98">8001 / 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe27eef1-1f4d-4b24-9620-4846169807b1">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fed23a55-2c90-4fb8-81e1-f8ba8aa51b0e">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111724">(111724, DCM, "Issuer of Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eca40f52-eb21-441a-afa6-6754aa8ba7a8">Case Medical Center</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6e3faa5-d6be-4d65-804d-890f3d5c8753">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d133423-d0b5-4fb3-8689-aeea40c5c4b2">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae453e40-1c76-4f73-9f7c-76a72be960b6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_929d97fd-a4cb-4613-8ad5-c62007cc07c5">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbb1a881-2963-43b9-b92e-b4a74c661ae5">
                                    <link xl:href="http://snomed.info/id/9265001" xl:show="new">(9265001, SCT, "Specimen Processing")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b6bd0dd-5f14-4545-bbf4-d2b7b61cf4de">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_884efc24-585b-4c9b-bcea-5fbff0f8a7e9">8001 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89071637-762f-4242-935d-6f18d97d55f7">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29cbd656-5402-4a98-89fd-6d3bec2cd42a">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111702">(111702, DCM, "DateTime of processing")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a28afc23-e0d1-46f7-bb61-17587f2863e5">200703240500</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a89acb85-0395-44b1-94c1-cd205ac05a02">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f224d3c-0771-4894-a4d5-f113b9cb0bd5">8001 / 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c489cc7-c76a-432b-a9b2-5e416533d432">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fef5c903-3e45-49ae-babe-d673a57437d5">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111703">(111703, DCM, "Processing step description")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cba14c5-1185-4e7c-b8a3-5fdfaa92d0f9">Embedding (paraffin)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cc89fd1-5021-4919-9af6-5d69f8144e87">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfb99f98-600b-4c05-bc22-3b148a6407c9">8001 / 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d48527b2-6c39-469a-a219-53f29f127940">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42e2983d-e96b-4323-9ca8-24f479bd8cdb">
                                    <link xl:href="http://snomed.info/id/430863003" xl:show="new">(430863003, SCT, "Embedding medium")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ade1ecb-984e-4b77-98e0-a432de33aa65">
                                    <link xl:href="http://snomed.info/id/255667006" xl:show="new">(255667006, SCT, "Paraffin")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="6">
                                <para xml:id="para_ceb24d5f-d3ca-46c1-b42c-29b69d4e7e77">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c18cae9-ae09-4f71-980b-9ff3f6fb9574">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_584da3c9-ca86-4f98-9511-8c185daee413">8001 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c7868d4-68a0-4a73-9a00-9b09f98e0db1">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f104306-d94e-42fa-9696-1333cb315c94">
                                    <olink targetdoc="PS3.16" targetptr="DCM_121041">(121041, DCM, "Specimen Identifier")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_070ca49c-b6e5-43b2-b045-62a5f009e8d0">S07-100 A 5 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="6">
                                <para xml:id="para_6fe66002-0a01-4653-bca5-1e41e482a730">Slide Staining</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1c815f7-206f-45bb-a369-58d402888fe4">2</para>
                            </td>
                            
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_164ade27-257b-4d02-9db7-abbe75700ec1">8001 / 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6b09ddb-ce2f-4f2c-91a9-fd2cf6804de3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af23e1fb-3718-40fe-8940-d29e8a44fdfd">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111701">(111701, DCM, "Processing type")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dd5cf82-3329-4f3f-9ede-bb28b9c1cf69">
                                    <link xl:href="http://snomed.info/id/127790008" xl:show="new">(127790008, SCT, "Staining")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0c6fe8b-faef-4486-a426-e1ebf307068b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcd8f694-81c3-4584-aabc-6e0ae2b7628f">8001 / 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0208be4c-f9bf-4b77-a2a8-31312adc230c">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f644c8e-7973-4234-95ce-06d8a4f32cbb">
                                    <olink targetdoc="PS3.16" targetptr="DCM_111702">(111702, DCM, "DateTime of processing")</olink>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e294da9f-08c3-4fe0-9100-32160fab9d7b">200703240700</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37b64ad8-b911-4b34-baef-f367a12c3af6">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8907d92d-d5ab-483c-b96a-c6b3e615c1f3">8001 / 9</para>
                                <para xml:id="para_85f0aaff-e78f-4d9e-9793-0e229c4dce3b">8003 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8420dcbd-0e22-4acd-91e1-d9cf8f7c9178">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a5ee542-7333-4f60-b31a-1ba69f80da44">
                                    <link xl:href="http://snomed.info/id/424361007" xl:show="new">(424361007, SCT, "Using substance")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b821850b-0625-412e-8bc6-2ecbb718e16b">
                                    <link xl:href="http://snomed.info/id/12710003" xl:show="new">(12710003, SCT, "hematoxylin stain")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a41f4c66-6ca1-4907-a10f-886533ba4cda">8001 / 9</para>
                                <para xml:id="para_6d273eea-d5a3-4703-b856-be1db270d068">8003 / 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d93c938-27c1-4240-9ad5-33ffe2c959bd">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_adf8b7d6-db0c-4515-b8f7-0885167ce253">
                                    <link xl:href="http://snomed.info/id/424361007" xl:show="new">(424361007, SCT, "Using substance")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c1b38ba-e207-4b2e-bd76-8f5b117d3b05">
                                    <link xl:href="http://snomed.info/id/36879007" xl:show="new">(36879007, SCT, "water soluble eosin stain")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">6</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">8001 / 9</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">8003 / 3</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                <emphasis role="bold"><emphasis role="underline"><link xl:href="http://snomed.info/id/127790008" xl:show="new">(127790008, SCT, "Staining")</link></emphasis></emphasis>
                            </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <emphasis role="bold"><emphasis role="underline"><link xl:href="http://snomed.info/id/104210008" xl:show="new">(104210008, SCT, "Hematoxylin and eosin stain method")</link></emphasis></emphasis>
                            </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        
        
        
        
        
    </chapter>
</book>