<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2078</title>
    <subtitle>Update DICOM to reflect changes in IHTSDO SNOMED CT-DICOM Subset for JUL 2020 INT Release</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/11/20</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                 xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>2020/09/08</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2078</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Update DICOM to reflect changes in IHTSDO SNOMED CT-DICOM Subset for JUL 2020 INT Release</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The following concepts have been inactivated in the July 2020 INT release</para>
                    <itemizedlist>
                        <listitem>
                            <para>110421000 Traumatic aneurysm ... no replacement yet - no action in this CP yet</para>
                        </listitem>
                        <listitem>
                            <para>180933005 Fifth ventricle - replace with 74968005 Structure of cave of septum pellucidum - UMLS considers these synonymous</para>
                        </listitem>
                        <listitem>
                            <para>23583003 Inflammation - replace with 409774005 Inflammatory morphology (French synonym of "infection" seems dubious)</para>
                        </listitem>
                        <listitem>
                            <para>244251006 Septal artery - no replacement yet ? restore BARI code ?- no action in this CP yet</para>
                        </listitem>
                        <listitem>
                            <para>24891006 Sodium diatrizoate-containing product - replace with 12335007 Product containing amidotrizoate (medicinal product)</para>
                        </listitem>
                        <listitem>
                            <para>277630003 Left ventricular basal septal segment - no replacement - delete</para>
                        </listitem>
                        <listitem>
                            <para>277631004 Left ventricle basal lateral segment - no replacement - delete</para>
                        </listitem>
                        <listitem>
                            <para>408720008 Left ventricular posterobasal segment - no replacement - delete</para>
                        </listitem>
                        <listitem>
                            <para>293638001 Allergy to X-ray contrast media - no replacement - delete</para>
                        </listitem>
                        <listitem>
                            <para>371951007 Vena anonyma - replace with 8887007 Structure of brachiocephalic vein (innominate vein)</para>
                        </listitem>
                        <listitem>
                            <para>372881000 Vasoconstrictor - replace with 870406003 Vasopressor</para>
                        </listitem>
                        <listitem>
                            <para>373262009 Cephalosporin antibacterial - replace with 764147003 Cephalosporin</para>
                        </listitem>
                        <listitem>
                            <para>40020002 Structure of middle lobe of lung - replace with 72481006 Structure of middle lobe of right lung</para>
                        </listitem>
                        <listitem>
                            <para>404846007 Gadopentetate dimeglumine-containing product - replace with 109216000 Gadopentetate dimeglumine (sunstance) </para>
                        </listitem>
                        <listitem>
                            <para>8361002 Tunica intima - replace with 87483006 Tunica intima of vessel</para>
                        </listitem>
                        <listitem>
                            <para>8568009 Abdominal lymph node structure - replace with 818991007 Structure of abdominal lymph node</para>
                        </listitem>
                        <listitem>
                            <para>95377006 Injection site reaction - replace with 95376002 Injection site disorder</para>
                        </listitem>
                    </itemizedlist>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        
        
        
        
        <section label="CID 12" status="3" xml:id="sect_CID_12">
            <title>Radiographic Contrast Agent</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c75a1725-0dae-4ed7-842c-42f8e12bf962">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_12.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_12.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_12.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.10.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_28d258c3-109d-4fe2-b45f-0a659465ba3c">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a787355e-f0d1-4a4f-870e-654aed92204b">
                            <emphasis role="bold"><emphasis role="strikethrough">20190817</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_96c21a04-cd66-4ff1-a740-a04183b20c25">
                            <emphasis role="bold">1.2.840.10008.6.1.10</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 12" rules="all" xml:id="table_CID_12">
                <caption>Radiographic Contrast Agent</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e93b6cd6-56fe-4621-aa65-6dd9c70a24f4">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de800243-bd1e-46fa-b17c-0ae87795d89d">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e71b400a-d759-4772-856d-de1b6aafe838">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cafd2be4-f594-466e-b8d2-bee7ccbf8c8b">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_548782ac-b577-4c6f-b672-e24e3cfe93a1">UMLS Concept Unique ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b50e2478-0428-4031-9813-40fec2459a64">Trade Name (Informative)</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a07c57a-0a31-4e6e-b075-b7e306ffadec">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5770b498-d851-44f2-a733-753c9b823870">
                                <link xl:href="http://snomed.info/id/12335007" xl:show="new">12335007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_69d1205c-0225-43be-bb1a-dc4f6148a8f4">Diatrizoate</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d1bff8a-a12c-4ec0-9f49-bb75da0a99f0">
                                <link xl:href="http://snomed.info/id/12335007" xl:show="new">C-B0317</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b49bfa3-941a-4784-9327-9ef139cf4ca8">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0012004" xl:show="new">C0012004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_24cc05e2-3087-44d4-a94c-90a5429d9def">Angiovist™(Berlex), Cardiografin™(Bracco), Cystografin™(Bracco), Gastrografin™(Bracco), Gastrovist™(Berlex), Hypaque™(GE), MD-nn™(Mallinckrodt), Reno-nn™(Bracco), Renografin™(Bracco), Renovist™(Bracco), Sinografin™(Bracco), Urovist™(Berlex)</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_88019b31-a60a-47d0-8261-4fc86ac5539c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4594d8ac-ed54-4506-81c9-f94fdcbe546c">
                                <link xl:href="http://snomed.info/id/47192000" xl:show="new">47192000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c35bcb7c-28d9-4e7d-a2e2-5c613a09f7f7">Meglumine diatrizoate</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cfc49270-718b-4ce2-9764-0efcc08c7ec4">
                                <link xl:href="http://snomed.info/id/47192000" xl:show="new">C-B0345</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90498d60-5e7d-47d9-94aa-d94cf06b218e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0012005" xl:show="new">C0012005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4cf378cd-f514-4ecd-9b41-4bf385d8faf7">Angiovist™(Berlex), Cardiografin™(Bracco), Cystografin™(Bracco), Gastrografin™(Bracco), Gastrovist™(Berlex), <emphasis role="bold"><emphasis role="strikethrough">Hypaque™(GE), </emphasis></emphasis>MD-nn™(Mallinckrodt), Reno-nn™(Bracco), Renografin™(Bracco), Renovist™(Bracco), Sinografin™(Bracco), Urovist™(Berlex)</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8b5e39d-b7bc-4d45-ac7a-a80b750ff495"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf4d94bb-45cc-4ac6-9076-27a0403c78b6">
                                <link xl:href="http://snomed.info/id/24891006" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">24891006</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c333ac45-5e12-490f-b7dc-47e52676730d"><emphasis role="bold"><emphasis role="strikethrough">Sodium diatrizoate</emphasis><emphasis role="underline"/></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b09ba7bf-ff60-4ac0-bb52-b80df96dc5f2">
                                <link xl:href="http://snomed.info/id/24891006" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C-B0347</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87e28bcd-f4bb-4a8f-84d6-4172dacfb705">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0012007" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0012007</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3b37d2ee-7a4b-4231-9b15-78a7258dd153"><emphasis role="bold"><emphasis role="strikethrough">Angiovist™(Berlex), Gastrografin™(Bracco), Gastrovist™(Berlex), Hypaque™(GE), MD-nn™(Mallinckrodt), Renografin™(Bracco), Renovist™(Bracco), Urovist™(Berlex)</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0da7c943-b805-4633-880e-f572a28f5228">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4937d9e3-030a-4303-b83c-4465ebbef9ce">
                                <link xl:href="http://snomed.info/id/404846007" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">404846007</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/109216000" xl:show="new"><emphasis role="bold"><emphasis role="underline">109216000</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_781bf74f-675c-4727-a34a-ef0fdedb35de">Gadopentetate dimeglumine</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9e1dbe3-c264-4851-9d0f-2aebef2122fb">
                                <link xl:href="http://snomed.info/id/404846007" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C-B014D</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/109216000" xl:show="new"><emphasis role="bold"><emphasis role="underline">C-B0321</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fcaf5e3d-9589-4925-9036-86e5ab0f9ca5">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0060934" xl:show="new">C0060934</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_65d5bb1f-c73f-419b-9cff-a78e174c4abb">Magnevist™(Berlex)</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 622" status="3" xml:id="sect_CID_622">
            <title>Medication Type Code Type from Anesthesia Quality Initiative (AQI)</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c5417ba4-31b2-45bd-a504-2734eb44ad27">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_622.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_622.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_622.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1087.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1d13b496-984f-42e9-aadc-5e56e54fd0e9">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1ee32ac4-d498-449d-8e37-ed00807212cd">
                            <emphasis role="bold"><emphasis role="strikethrough">20190817</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_eb732c7f-841b-4253-894c-87d9f7439faf">
                            <emphasis role="bold">1.2.840.10008.6.1.1087</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 622" rules="all" xml:id="table_CID_622">
                <caption>Medication Type Code Type from Anesthesia Quality Initiative (AQI)</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_28ded19d-6cfd-4cc3-b5bb-d3b92f43c582">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b748ba06-cfa9-4de0-9efe-9c5105225c2e">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_927fa79c-b7ff-4d01-95be-62db9d7448fd">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a662d96-b1f7-4eae-b493-5cc81b3302ca">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22354493-726c-4dcf-90b6-94fd936142ce">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1eda157e-9abf-48cf-8162-d10a5c933783">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ba2a605-dcc4-4a42-b766-0ef3e8a6a55b">
                                <link xl:href="http://snomed.info/id/373262009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">373262009</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/764147003" xl:show="new"><emphasis role="bold"><emphasis role="underline">764147003</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d0d0bcdb-8df4-456e-8d08-44cf61ae4abc">Cephalosporin antibiotic</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a0fd6e6-8fe0-4992-92aa-ea2a229901e4">
                                <link xl:href="http://snomed.info/id/373262009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C-0021C</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_10ce033e-82df-437d-8ef6-cb14cfa302bf">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C3536856" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C3536856</emphasis></emphasis></link>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4706514" xl:show="new"><emphasis role="bold"><emphasis role="underline">C4706514</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98da0fcf-96f0-424d-8067-3ab3d44370dc">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5271ee8c-8489-48cd-b5b0-16716ee222ee">
                                <link xl:href="http://snomed.info/id/372881000" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">372881000</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/870406003" xl:show="new"><emphasis role="bold"><emphasis role="underline">870406003</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a430eb59-85f3-42f2-ad76-67b4d92c822d"><emphasis role="bold"><emphasis role="strikethrough">Vasoconstrictor</emphasis><emphasis role="underline">Vasopressor</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d5fe177-892a-4ecf-a7b9-6caa4a5dc1d8">
                                <link xl:href="http://snomed.info/id/372881000" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">F-619AA</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fd670581-e632-4b61-a97e-a0452bfa824c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0042397" xl:show="new">C0042397</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <para xml:id="para_73953910-f830-47fc-8fdf-8353c472d724">The AQI value "Vasopressor" corresponds to <link xl:href="http://snomed.info/id/870406003" xl:show="new">(<emphasis role="bold"><emphasis role="strikethrough">372881000</emphasis><emphasis role="underline">870406003</emphasis></emphasis>, SCT, "<emphasis role="bold"><emphasis role="strikethrough">Vasoconstrictor</emphasis><emphasis role="underline">Vasopressor</emphasis></emphasis>")</link>.</para>
            </note>
        </section>
        
        <section label="CID 1200" status="3" xml:id="sect_CID_1200">
            <title>Contraindications For CT Imaging</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_fc776978-712e-404c-ba3b-067fed3bb4be">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_1200.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_1200.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_1200.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1131.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6983fc52-f387-46f5-811d-053040aee96c">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_dcbc4525-2126-47f6-8cdf-18376c3bda80">
                            <emphasis role="bold"><emphasis role="strikethrough">20160905</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a3d3eabc-dd6d-4d5a-94db-1bae6fc020a9">
                            <emphasis role="bold">1.2.840.10008.6.1.1131</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 1200" rules="all" xml:id="table_CID_1200">
                <caption>Contraindications For CT Imaging</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_745ddac5-6da4-4e77-b45c-de7281df4fb2">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a74ef94f-4176-4d12-8c50-38d7a208c1b8">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9b622c5-3eb8-47e3-bb74-5e9efbca415f">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c3a4b7fb-6e4d-4fbd-81cc-4bbcb84ae3ab">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0b59fe61-8987-40b9-a641-1f1d6a505fa1">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2dfb6e3-1f20-4515-8b46-130ca789ce06"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9adbe6b-5c02-4cd8-bc41-624e7fc2096c">
                                <link xl:href="http://snomed.info/id/293638001" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">293638001</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d0ac3aa9-0f90-4e51-b013-fb9770f29a1e"><emphasis role="bold"><emphasis role="strikethrough">X-ray Contrast Media Allergy</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_112cd8f7-180b-4f22-b6bb-46793a23badd">
                                <link xl:href="http://snomed.info/id/293638001" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">DF-10F42</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_863e6d69-354a-4ea7-b6ad-46a09eb73810">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0570563" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0570563</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d9c9c76-baad-4b17-a91d-84eee7df9347">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3812a43-72b9-4221-b335-90335e411fc6">
                                <link xl:href="http://snomed.info/id/293637006" xl:show="new">293637006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5a1edfaf-af9a-4d50-8a8e-e916859c2d82">Contrast Media Allergy</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e30d07c8-0e70-4477-a2fd-0dbbd76ca706">
                                <link xl:href="http://snomed.info/id/293637006" xl:show="new">DF-10F41</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_adf54b8b-bef7-438e-b62b-fbbb91a4b3c3">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0570562" xl:show="new">C0570562</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6778bbe2-bb29-4680-8a01-3ff2aa0f98c3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6e64427-9652-45ac-828b-3208c1fd1a58">
                                <link xl:href="http://snomed.info/id/77386006" xl:show="new">77386006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_785f6002-5e58-43cc-9766-3f096d14db68">Patient currently pregnant</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08dedb7c-ac38-4ca3-ab39-da57c80dcec7">
                                <link xl:href="http://snomed.info/id/77386006" xl:show="new">F-84000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7fd3ab97-b1b1-480e-95ab-92233c1eb272">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0549206" xl:show="new">C0549206</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7231a1d4-9d9a-4133-a967-76fce7513e10">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62c712c2-dd2d-4aae-ae69-658c450810e4">
                                <link xl:href="http://snomed.info/id/236423003" xl:show="new">236423003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_828a7304-3492-455b-92c3-c22ddac57279">Impaired Renal Function</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eeeabd1b-84eb-4fad-906e-de862d73a98e">
                                <link xl:href="http://snomed.info/id/236423003" xl:show="new">D7-11007</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_591c0cf8-2fa7-454c-96de-b7f92baaf93d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1565489" xl:show="new">C1565489</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        
        
        <section label="CID 3014" status="3" xml:id="sect_CID_3014">
            <title>Coronary Artery Segments</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_8e854698-1709-4537-aec8-6508df836fbd">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_3014.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_3014.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_3014.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.47.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d9f4b303-a727-4c37-b8de-aa72f1abb5f1">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_28af8ee1-6cf4-43a2-88bd-d915cc410f5c">
                            <emphasis role="bold"><emphasis role="strikethrough">20180325</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_cd346765-3da2-4e08-852e-a193bae480fa">
                            <emphasis role="bold">1.2.840.10008.6.1.47</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 3014" rules="all" xml:id="table_CID_3014">
                <caption>Coronary Artery Segments</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a079f946-c672-40ba-b254-fb20962e09d1">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a4ef8f84-4a3f-489c-b2a1-2a4a64efa21c">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46f4be6a-8c5f-4ff1-b756-1caaa987c32d">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d96641d-ece6-4be8-a4d1-e8d75a935a24">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e9309ba-515d-4d6d-82b0-0d3900be8f9c">UMLS Concept Unique ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec27b343-9c0f-40ee-877b-c83549dc8f78">Equivalent BARI Code</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c46b8cf7-4eb8-482b-90aa-e2b97af6c74b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eed009a9-b826-4559-b3f1-368a6d38d56c">
                                <link xl:href="http://snomed.info/id/244251006" xl:show="new">244251006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_40ab268d-86e7-4fd3-842b-8a7ed2b54e11">1st Septal Coronary Artery</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e36a2ee6-f618-42ee-b58e-1d5d616c22be">
                                <link xl:href="http://snomed.info/id/244251006" xl:show="new">T-43002</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ffc6ee26-6dee-445b-b214-28f23638fcce">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0447058" xl:show="new">C0447058</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60d88d7a-f6f3-40f0-8c98-aa54585767b3">17</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
 
 <section label="CID 3808" status="3" xml:id="sect_CID_3808">
            <title>Aneurysm Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1952625d-ebdd-4afe-a9e8-b6e6eea58665">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_3808.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_3808.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_3808.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.269.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c1c955a5-0f25-44b6-97f0-038bf15d5c56">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5d23ffbc-5595-4900-aef1-d172f4f2ae87">
                            <emphasis role="bold"><emphasis role="strikethrough">20180325</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_0854b4d9-d76e-4835-8c03-9914f3d98bb9">
                            <emphasis role="bold">1.2.840.10008.6.1.269</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 3808" rules="all" xml:id="table_CID_3808">
                <caption>Aneurysm Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9d5080d-25e1-4c92-bcf3-c5f232608877">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09b2b5f9-474c-4e83-adca-265bb21d9d8b">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_621ede59-bea1-466c-8631-050b6bacf119">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd9f75c4-8574-48de-abc0-51e4c3cc7906">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6145286c-1a92-449e-a8be-6862595003cc">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e23fb86-5614-4f35-9d7d-35667effcde5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e0938b6-be1b-4f88-a708-1ddbc5bb3603">
                                <link xl:href="http://snomed.info/id/110421000" xl:show="new">110421000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_070e5bd2-7529-4ef2-884e-ff6120e78725">traumatic aneurysm</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47d9e0c4-45ae-4a80-b4e9-4ca7f49a0471">
                                <link xl:href="http://snomed.info/id/110421000" xl:show="new">M-32210</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59fc6e6e-33bb-4589-b2ae-b45b3b7a133c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1527161" xl:show="new">C1527161</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        <section label="CID 3607" status="3" xml:id="sect_CID_3607">
            <title>Venous Source Locations</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6abcf3a9-50be-482e-9e1c-c6a901a8cceb">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_3607.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_3607.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_3607.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.157.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_3f4dabe8-627c-4498-a65b-d62e7dc5aafd">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f8e90d7e-7fb3-4df8-bdd8-65dd80efc90e">
                            <emphasis role="bold"><emphasis role="strikethrough">20180605</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_17a9fcef-6237-4713-822d-ceba611bb44c">
                            <emphasis role="bold">1.2.840.10008.6.1.157</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 3607" rules="all" xml:id="table_CID_3607">
                <caption>Venous Source Locations</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_471fd3e3-175c-42db-849b-4844dee0b71a">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91eeace1-7e07-465e-a778-80323120549c">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e547e0c6-7350-42dc-a755-3c8e10961680">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f60e8e6c-7fc9-4676-b892-82b39cb93e00">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e4112ce-f774-4c6f-bd08-7844fe88ef68">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2396079-7712-4a20-9175-7414e3eb468d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_122ca074-1da1-43c0-89c2-4b3c13801b17">
                                <link xl:href="http://snomed.info/id/8887007" xl:show="new">8887007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_001fb950-c67b-4d96-9375-c4da1a75fc6c">Innominate vein</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22cb99ee-94e9-4532-98f5-c21c9241e7d7">
                                <link xl:href="http://snomed.info/id/8887007" xl:show="new">T-48620</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f30acd7b-2fa7-4da1-b387-8a4c4e52a5e9">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0006095" xl:show="new">C0006095</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1d104af-3b29-4055-872c-cc919a208d0f"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40150473-e9e8-4261-8b51-6df3ad9f87cb">
                                <link xl:href="http://snomed.info/id/371951007" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">371951007</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_587cf2e8-658e-441a-bda7-b3a18802faa8"><emphasis role="bold"><emphasis role="strikethrough">Vena anonyma</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b58d8660-d484-49ce-acf3-8ccfe3e2e2c5">
                                <link xl:href="http://snomed.info/id/371951007" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">R-003AA</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7a3310f-f52e-47af-97b1-111b4952a71a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1299265" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C1299265</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 3718" status="3" xml:id="sect_CID_3718">
            <title>Myocardial Wall Segments in Projection</title>
            <para xml:id="para_7ec0478f-8782-4f1b-bf75-fe1eb6df25bd">This context group specifies the left ventricular myocardial wall segments as seen in typical right anterior oblique (RAO) and left anterior oblique (LAO) angiographic projections.</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6d22ffe9-0b87-42ec-8c62-2c0cc6568ed8">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_3718.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_3718.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_3718.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.219.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_215b9f3d-8177-4c20-a249-f725ca42710a">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_cbd9f32f-0ab8-4588-b883-cc73621059fd">
                            <emphasis role="bold"><emphasis role="strikethrough">20030614</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6519f7f8-c8f0-4800-aa27-9da36dae7f40">
                            <emphasis role="bold">1.2.840.10008.6.1.219</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 3718" rules="all" xml:id="table_CID_3718">
                <caption>Myocardial Wall Segments in Projection</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21cd0b29-a6c7-4ddd-b448-b91bee0212a8">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_671d290a-d5d2-4170-814d-30438190b6e3">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6dafa835-a1ca-40a4-b67b-4e3d36bd777d">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76fdff95-da9e-4191-a37d-b2c4ee7deaf4">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7332418c-9ae3-4cc4-b50a-61824f30aabc">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1a4cdf1-9366-47c8-93df-d8c3e2a54beb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ad1a751-ab24-4d29-810c-3032093db750">
                                <link xl:href="http://snomed.info/id/264850008" xl:show="new">264850008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_18f7363b-67fe-4568-96b0-5c22a402dbc2">left ventricle basal anterior segment</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d90d03b6-f5c2-429b-a5a0-c7c1e1e4f372">
                                <link xl:href="http://snomed.info/id/264850008" xl:show="new">T-32619</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef9ce5f6-9dd8-4589-9314-8b48f7d093c0">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0555926" xl:show="new">C0555926</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d33f08d3-77b0-47b5-88fb-ecbea5b3c8e6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8ad31398-da70-4f7e-b475-ba388e4267ad">
                                <link xl:href="http://snomed.info/id/73050001" xl:show="new">73050001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bae7f76e-a0ee-4e4e-9dd5-4bd72b75ef97">myocardium of anterolateral region</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d20cbfe1-7d12-45c2-a3dc-1991dc1ad476">
                                <link xl:href="http://snomed.info/id/73050001" xl:show="new">T-32634</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47009a8f-c374-4c9d-b541-e089a965c7aa">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0225907" xl:show="new">C0225907</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c91b65f-2d5c-4c7f-90e0-5247d0fcf33d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6879c52-d029-48ba-86b8-6ee9c8b679ed">
                                <link xl:href="http://snomed.info/id/47962008" xl:show="new">47962008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_27759ed1-1c06-442b-a534-dd8dd80368db">myocardium of apex of heart</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5bf16776-50a7-4afc-967a-f9bf4dc33ca5">
                                <link xl:href="http://snomed.info/id/47962008" xl:show="new">T-32636</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e77a5ca-a9e7-4b7f-8a7c-a2c8bc437613">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0225909" xl:show="new">C0225909</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_88d05f05-2f84-490e-9aba-6118c0aee502">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d914d69-2496-4185-9e87-b799c24bed28">
                                <link xl:href="http://snomed.info/id/72542009" xl:show="new">72542009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a6a4b933-76f1-4d1a-b411-6d597234614d">myocardium of diaphragmatic region</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0d1d347-1251-4e15-91d7-2271cbedde2a">
                                <link xl:href="http://snomed.info/id/72542009" xl:show="new">T-32632</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8888448d-fbb0-4a0f-9c79-6c158b8118b8">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0225905" xl:show="new">C0225905</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a0aeb68e-cf2d-4206-8afc-e13095de3e7c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a0823008-1acd-44aa-be23-9e379e7667fc">
                                <link xl:href="http://snomed.info/id/264846001" xl:show="new">264846001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_247e8e67-8204-4096-8cc3-c367a7262e8d">left ventricle basal inferior segment</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a461cbd1-3b19-4e6c-b474-16256766db0d">
                                <link xl:href="http://snomed.info/id/264846001" xl:show="new">T-32615</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e37b7948-1a31-4f40-8398-5b8f5da4e395">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0555929" xl:show="new">C0555929</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f9432c0a-7a66-4705-bbdc-3f0a8c495755"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5100ba8a-db53-4b14-9bb1-c619e45f45e3">
                                <link xl:href="http://snomed.info/id/277631004" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">277631004</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8eba0f0a-7943-4a33-8693-cf7a91f7b6dd"><emphasis role="bold"><emphasis role="strikethrough">left ventricle basal lateral segment</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf1ba7aa-0226-4693-b1b9-8c0a964988af">
                                <link xl:href="http://snomed.info/id/277631004" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">T-32603</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fed0d5c4-64fc-46c3-98af-5998bb5b146a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0559192" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0559192</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b603b712-412f-49f6-b09a-71540852968a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04d1356b-b7fd-4ba6-82c8-e104ad05b779">
                                <link xl:href="http://snomed.info/id/33272004" xl:show="new">33272004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a748394f-e981-4967-8217-e2091b3617c1">myocardium of posterolateral region</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96c49919-671e-4e60-89e3-31bfbc2fcc42">
                                <link xl:href="http://snomed.info/id/33272004" xl:show="new">T-32633</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99156ffa-9be9-4238-a788-9cec374499e0">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0225906" xl:show="new">C0225906</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc925474-d62f-4297-b362-31c23d765c97">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42b1fa6b-7262-40eb-9385-11ff328e0973">
                                <link xl:href="http://snomed.info/id/16239001" xl:show="new">16239001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bac8e3bc-c6cc-40ef-a6c2-f16516b073e8">myocardium of inferolateral region</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_714f5010-9621-4326-bfc9-ee7052b9f6aa">
                                <link xl:href="http://snomed.info/id/16239001" xl:show="new">T-32637</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c96a23a7-ffdc-422e-9ffb-b8a51c041f00">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0225910" xl:show="new">C0225910</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e717c806-cb2c-4e7e-9011-706243b53f1a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3357b9d4-7fcf-4191-a813-5a7fb27f1c2a">
                                <link xl:href="http://snomed.info/id/264845002" xl:show="new">264845002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_61fdbc88-9274-4262-a817-beaca7e91081">left ventricle apical septal segment</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ec73bde-598f-466a-970c-4eb6c40b3c5c">
                                <link xl:href="http://snomed.info/id/264845002" xl:show="new">T-32614</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa7e7409-9e54-4b83-ad25-79ac5f1624f1">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0555923" xl:show="new">C0555923</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8113fba5-b363-4bd8-a779-f053c5a8eef9"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a94250f7-6bd1-44bd-8214-21a82888a5e4">
                                <link xl:href="http://snomed.info/id/277630003" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">277630003</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a872f0b6-ab5e-4392-a15a-1c7139b25a1b"><emphasis role="bold"><emphasis role="strikethrough">left ventricular basal septal segment</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2416084f-4d28-4518-abc4-68de08f6ff2a">
                                <link xl:href="http://snomed.info/id/277630003" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">T-32601</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_882ad4a9-3917-4cc3-8192-cba6c6a20647">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0559191" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0559191</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f902101a-f68c-4865-925c-75ce7590d5d8"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89bb8825-bf5b-4f9b-b11c-cf2458c72796">
                                <link xl:href="http://snomed.info/id/408720008" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">408720008</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c8f8cf6d-73e5-402f-a1b8-76773dbacf03"><emphasis role="bold"><emphasis role="strikethrough">left ventricular posterobasal segment</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_176aeeef-3447-46da-be61-8f41048e0237">
                                <link xl:href="http://snomed.info/id/408720008" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">R-101C0</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14aba0cc-d913-449b-9ccb-db376f7a7b84">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1443269" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C1443269</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 6031" status="3" xml:id="sect_CID_6031">
            <title>Benign Pathology Codes from BI-RADS®</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5be503ba-a49b-4db1-a7ae-164223e2324b">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6031.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_6031.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_6031.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.361.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f1b45b0f-85c3-42e9-8b51-7a8356a8bdf0">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6a94c1aa-ac49-4b32-bf8d-6be23cef18b8">
                            <emphasis role="bold"><emphasis role="strikethrough">20170914</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_550e41ad-6cc1-4ab9-b861-c81ebd44dfe7">
                            <emphasis role="bold">1.2.840.10008.6.1.361</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 6031" rules="all" xml:id="table_CID_6031">
                <caption>Benign Pathology Codes from BI-RADS®</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0adf0d14-1f57-4cbb-8bf0-403fce79482b">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e85db16d-e237-4f9b-ba30-eddc24225659">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c3e7d026-1891-4b81-b14a-d9813e31ac64">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3ee4e95-c670-4350-be55-7c8abea55e3f">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_49cb9df7-2078-404f-844c-f94f32aff421">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f3a0154-423f-489f-af2a-040d1141cb53">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ffb49d2-2e86-4122-a291-52181e93ca6c">
                                <link xl:href="http://snomed.info/id/23583003" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">23583003</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/409774005" xl:show="new"><emphasis role="bold"><emphasis role="underline">409774005</emphasis></emphasis></link>               
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_db7c2585-e67a-4bf7-9d7f-e52d3c1919c9">Inflammation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ecfb0557-d558-49e8-8f7d-4968a6e93a63">
                                <link xl:href="http://snomed.info/id/23583003" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">M-40000</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/409774005" xl:show="new"><emphasis role="bold"><emphasis role="underline">M-0100C</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f03acf0-c8aa-4ee7-b302-f84403c50d92">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0021368" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0021368</emphasis></emphasis></link>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1444073" xl:show="new"><emphasis role="bold"><emphasis role="underline">C1444073</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 6126" status="3" xml:id="sect_CID_6126">
            <title>Location in Lung</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_965fdf46-32b4-4332-8b44-0e5f1e12d855">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6126.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_6126.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_6126.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.446.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_83981db0-b31a-42e3-9579-9988c2698e51">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d51263a0-8b39-4a30-ba7d-f8246c38e457">
                             <emphasis role="bold"><emphasis role="strikethrough">20030108</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_297d7460-0df7-41ea-9f0e-e3c426a1f237">
                            <emphasis role="bold">1.2.840.10008.6.1.446</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 6126" rules="all" xml:id="table_CID_6126">
                <caption>Location in Lung</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb4b980e-ddb4-43ff-9b3f-0fd53fa0518f">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7872918b-3cf7-4cf6-a71a-9d52aedc6650">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9efa64d0-650a-4a72-ba3c-b9d0188ae22c">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6c6c4c8-c062-48be-8283-b4edc2cf9a61">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e4a4928-6e50-4481-8747-7e85e546891c">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_861a111f-beb5-4493-b106-40bf796b6726">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022044c1-9443-496a-bde2-cffdc59528ab">
                                <link xl:href="http://snomed.info/id/281392002" xl:show="new">281392002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3ae7abed-091f-491a-a978-2f66301cc293">Upper zone of lung</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa618db6-03de-43c8-a295-7b2d6bc3a992">
                                <link xl:href="http://snomed.info/id/281392002" xl:show="new">T-D3208</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e39d93d-974c-42cb-84c8-7f655d5e4753">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0559286" xl:show="new">C0559286</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2036d38d-75be-43be-a058-5b481ef9971d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eef5259d-93d5-4fb4-97c8-b160bddf3996">
                                <link xl:href="http://snomed.info/id/281393007" xl:show="new">281393007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3163ccbe-d444-49c1-ba12-671930be790e">Middle zone of lung</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e3b0c0e-2eb3-4bff-87e3-97c2a6504b05">
                                <link xl:href="http://snomed.info/id/281393007" xl:show="new">T-D3209</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6857b27c-97d5-48fe-a0c3-9585f9869b13">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0559287" xl:show="new">C0559287</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8fdbdaca-d0cc-48a5-80ac-5cb91162dc3c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_69e42b35-82c5-4517-8bfa-c69a0e8dbee3">
                                <link xl:href="http://snomed.info/id/281394001" xl:show="new">281394001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2a6fbb9e-e6bc-4186-8db0-7ca53b852d7c">Lower zone of lung</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2fd77cb5-d6c7-4b60-9c7f-32e30f9021ad">
                                <link xl:href="http://snomed.info/id/281394001" xl:show="new">T-D320A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_32b39f7d-bd95-4ebe-88b3-245a22092259">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0559288" xl:show="new">C0559288</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_33d68c4f-fd95-4c32-9c69-12495f5729ab">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60bf90ae-7036-42b9-b7fa-88eaaaa6dca7">
                                <link xl:href="http://snomed.info/id/45653009" xl:show="new">45653009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_da2603b7-33cf-4189-b913-4403aaf0f8d4">Upper lobe of lung</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f40a2cfd-5086-4d15-8f89-ec1cb7fa076d">
                                <link xl:href="http://snomed.info/id/45653009" xl:show="new">T-28820</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ded74c9b-c433-4dc8-bc2a-8d49f639bf47">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0225756" xl:show="new">C0225756</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bf52680c-3b0b-405b-9006-2edcef28c20d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_758961a7-a318-4f19-a85e-956f0d7fa820">
                                <link xl:href="http://snomed.info/id/40020002" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">40020002</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/72481006" xl:show="new"><emphasis role="bold"><emphasis role="underline">72481006</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_56f7428d-6046-47a9-bbc0-dfb70186997b">Middle lobe of <emphasis role="bold"><emphasis role="underline">right</emphasis></emphasis>lung</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8fc6ed8b-ed0c-4803-95c6-b06dd911d8ee">
                                <link xl:href="http://snomed.info/id/40020002" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">T-28825</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/72481006" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-28300</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2fa221b-fe43-49b8-bfac-3380c5e1020d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0225757" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0225757</emphasis></emphasis></link>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4281590" xl:show="new"><emphasis role="bold"><emphasis role="underline">C4281590</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a10e650e-2f0f-4dbb-be85-bd41e0aeb5fd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_719a3564-5b8b-43d7-a125-a3c1cb4438e1">
                                <link xl:href="http://snomed.info/id/90572001" xl:show="new">90572001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_057554be-d13b-4a7b-bcac-db56f5d04d36">Lower lobe of lung</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2bfbd56-da4a-4649-bcf3-a8a7a458ed21">
                                <link xl:href="http://snomed.info/id/90572001" xl:show="new">T-28830</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b1dd822d-33fe-4403-b07e-3b59eee7b97b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0225758" xl:show="new">C0225758</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d6ae55cf-3bb6-418a-985c-3603ac630504">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0f0a491-41ff-497e-af2a-d96f3eecb654">
                                <link linkend="DCM_112153" xrefstyle="select: nopage">112153</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e1d956fc-a8a6-435e-8e35-7500e407d05c">Subpleural</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0a3542b-a759-4355-a9aa-e3d990fac92e"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ccf9d4c-1859-43dc-b01e-e56dc35e303b"/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 7140" status="3" xml:id="sect_CID_7140">
            <title>Brain Structures for Volumetric Measurements</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d81798c6-65ef-4ed3-a68e-f92eb3c72e78">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7140.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7140.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7140.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.967.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_36face7e-90ba-4f81-96aa-3f47b61beacf">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c5b7521c-60da-4fbc-90cb-1fb33c9c889b">
                            <emphasis role="bold"><emphasis role="strikethrough">20170914</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_b0e5191e-1862-4cae-b156-b24a9fd2e131">
                            <emphasis role="bold">1.2.840.10008.6.1.967</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7140" rules="all" xml:id="table_CID_7140">
                <caption>Brain Structures for Volumetric Measurements</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87b0a399-dfe7-4115-b068-15ceae33568f">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c6ed55a-ddb1-4626-9840-51c46a3c81a9">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d078468-c5cc-4a57-ac10-69879ef1b21a">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9fbcbe0-f817-41a1-ba97-8ecdaa2b9c9a">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22b3752b-a69e-428b-95a2-fec9c6bbdf4a">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1370ca48-23da-4ca9-ba03-cdc4437d0821">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_511e5621-1b5c-4e27-8ea9-5a62186c40ca">
                                <link xl:href="http://snomed.info/id/180933005" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">180933005</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/74968005" xl:show="new"><emphasis role="bold"><emphasis role="underline">74968005</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_94cb2957-84d6-451d-8ff9-ca7b6c8f7307"><emphasis role="bold"><emphasis role="strikethrough">Fifth Ventricle</emphasis><emphasis role="underline">Cavum of septum pellucidum</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7c0b4899-7d8b-4ad6-b1b1-a41e958d311e">
                                <link xl:href="http://snomed.info/id/180933005" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">T-A1604</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/74968005" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-A1630</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_919c3cda-1933-402b-8bb5-017cfe814e21">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0228158" xl:show="new">C0228158</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        <section label="CID 7156" status="3" xml:id="sect_CID_7156">
            <title>Vascular Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_7b05c55a-ff83-4470-a0ae-d972e9e5c5b6">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7156.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7156.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7156.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.502.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6ebad58b-c4c9-41aa-878f-f71d8498388f">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_3c91cd29-27e2-44e8-8f10-f45cb2e08428">
                            <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f2d6d802-5e2d-4642-a5ce-8bb5b4111630">
                            <emphasis role="bold">1.2.840.10008.6.1.502</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7156" rules="all" xml:id="table_CID_7156">
                <caption>Vascular Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_782039f5-ed6f-4c63-b9fd-034a0668f0f7">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46e2669d-e2ab-4f96-872d-1c77cf413777">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a4bf954-fc22-497e-a363-e754ce2f2acc">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c678405c-7f19-4257-9b86-ff498b9ee23c">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_349bdda0-2607-435f-9965-f3b3648ea499">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c21ebf7-ac25-456a-90fa-944502c80df5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d064e58-07e5-4874-9283-b22cda5eb1e8">
                                <link xl:href="http://snomed.info/id/8361002" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">8361002</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/87483006" xl:show="new"><emphasis role="bold"><emphasis role="underline">87483006</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_05a150c0-4c49-4634-8769-c6da299f0344">Intima</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_586388e9-9cb3-4817-9e29-a2b07a82e5ec">
                                <link xl:href="http://snomed.info/id/8361002" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">T-1A170</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/87483006" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-40200</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d33dc101-9991-4ddc-b764-a7127fa76c0f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0162864" xl:show="new">C0162864</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        <section label="CID 7159" status="3" xml:id="sect_CID_7159">
            <title>Lesion Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_091d9c60-0554-4643-824b-efbd4b9a9994">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7159.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7159.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7159.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.505.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_bb393902-4078-44bd-9ae0-4875b2517a86">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_504d4909-831f-40e7-a7c8-ae2d1693887d">
                            <emphasis role="bold"><emphasis role="strikethrough">20190327</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_9e2a9b52-125c-4848-a39e-2553eefba12e">
                            <emphasis role="bold">1.2.840.10008.6.1.505</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7159" rules="all" xml:id="table_CID_7159">
                <caption>Lesion Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c361624d-3f16-4891-9e29-7eed9774cf94">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78efd284-51a8-4fff-b247-4984c6c10b86">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a4b3364-06dc-40e7-b361-36483cb66291">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56308830-2323-4fc3-b59e-d4f889e18fc5">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad839f1e-076f-4b1d-aa66-a984e12a0fb1">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_549455d9-df11-4da7-bb3e-75e82137ae55">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d4325cd-2123-4c14-b465-2bc590105e1c">
                                <link xl:href="http://snomed.info/id/23583003" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">23583003</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/409774005" xl:show="new"><emphasis role="bold"><emphasis role="underline">409774005</emphasis></emphasis></link>               
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b0767a0d-ee52-45c8-bcd0-c22e12976a0c">Inflammation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d496b87f-5a0b-45bf-bd6c-0b8e6260f1b4">
                                <link xl:href="http://snomed.info/id/23583003" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">M-40000</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/409774005" xl:show="new"><emphasis role="bold"><emphasis role="underline">M-0100C</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_97ad421c-ab60-407e-a593-07d8ac245212">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0021368" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0021368</emphasis></emphasis></link>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1444073" xl:show="new"><emphasis role="bold"><emphasis role="underline">C1444073</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 7600" status="3" xml:id="sect_CID_7600">
            <title>Lymph Node Anatomic Sites</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_b949dace-26f8-4144-a7ef-3fe8b82d03db">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7600.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7600.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7600.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1011.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a6ff8e8c-26da-4856-851d-30ecfd810aa7">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ae358b80-ee55-4a15-b815-065983d8d5f3">
                            <emphasis role="bold"><emphasis role="strikethrough">20190817</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1716ab31-4db7-4b0d-944f-85155f66fe12">
                            <emphasis role="bold">1.2.840.10008.6.1.1011</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7600" rules="all" xml:id="table_CID_7600">
                <caption>Lymph Node Anatomic Sites</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_785ce584-3802-4872-a0df-609f03e91d76">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b5c50b4-7575-493e-8fd8-c275673c715f">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e4f253b-2395-4c35-be6d-d3f14fecb709">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8b4c2c18-089c-49c7-b015-78aa7c1e1804">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_968a7f57-d515-4180-83e9-816be4e07f2b">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e29ac6b6-8e1d-405a-9808-846134e22180">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1db04256-1a7d-4713-b711-878ed0b25c31">
                                <link xl:href="http://snomed.info/id/8568009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">8568009</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/818991007" xl:show="new"><emphasis role="bold"><emphasis role="underline">818991007</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e5976959-5bff-4cd3-bec1-c492f13a77ca">abdominal lymph node</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96f74dfa-d05b-4623-ab03-586bfcff8c68">
                                <link xl:href="http://snomed.info/id/8568009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">T-C4400</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_67f4dd4d-8a07-49a5-9613-dab2e7a9f55e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0588058" xl:show="new">C0588058</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 10043" status="3" xml:id="sect_CID_10043">
            <title>Intravenous Extravasation Symptoms</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_491a0eba-4b81-4c09-a3ba-e05b32351b80">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_10043.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_10043.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_10043.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.975.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_e495cb71-c930-4057-93cc-c4a798a95250">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_2e2a6e06-9a2d-429f-89b3-8b2586cb6fca">
                            <emphasis role="bold"><emphasis role="strikethrough">20140419</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_cc7aea2d-c4cc-4010-a188-b655ed607a57">
                            <emphasis role="bold">1.2.840.10008.6.1.975</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 10043" rules="all" xml:id="table_CID_10043">
                <caption>Intravenous Extravasation Symptoms</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4df380d-5c1a-4b2d-8c41-c8a2c0c76e6e">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_894b6b43-c5e5-4a09-a1df-7e83da48f026">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d7fa080-1b12-4a4c-8b10-4f537b7b5ca4">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a417ecc-c71a-4998-91ca-87f686c2c0bc">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e9330b2-7351-4821-9c9d-f38ff1572ace">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_524a2ad9-0673-4fc0-9883-95ede0635df4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4dd8d18b-8349-4f2d-bab9-829603ae69ca">
                                <link xl:href="http://snomed.info/id/95376002" xl:show="new">95376002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c6748b85-9fc5-4f12-8238-7a828c9049a6">Injection site disorder</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_521ae2ad-32ed-4518-8d7b-c9ec544c668b">
                                <link xl:href="http://snomed.info/id/95376002" xl:show="new">D0-B0300</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dd39ef4a-4d3f-4ead-b2a9-0861b4f3ff43">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0521497" xl:show="new">C0521497</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_51d9c068-6e42-4953-9643-b79b6904263e"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9a3d3b77-fc43-4af6-862b-dbed09500893">
                                <link xl:href="http://snomed.info/id/95377006" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">95377006</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8ea1c070-7be4-4f54-96ba-7eaec67350af"><emphasis role="bold"><emphasis role="strikethrough">Injection site reaction</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8d99e0f-0853-4348-9300-7e5f99a2fd71">
                                <link xl:href="http://snomed.info/id/95377006" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">D0-B0310</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46643b1c-bbd1-47b5-97f1-e6b8e8be2416">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0151735" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0151735</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 12292" status="3" xml:id="sect_CID_12292">
            <title>Cardiac Ultrasound Coronary Arteries Finding Sites</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5c4bc94f-bc8f-4201-9c96-7fb2442d6779">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_12292.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_12292.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_12292.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.872.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_9c2182ba-1087-4089-9787-1019dedbe8d5">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_dee2e9f1-aa49-413a-804b-75d8be15f970">
                            <emphasis role="bold"><emphasis role="strikethrough">20170914</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c1f0b442-a030-4888-8b26-3f103b78f892">
                            <emphasis role="bold">1.2.840.10008.6.1.872</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 12292" rules="all" xml:id="table_CID_12292">
                <caption>Cardiac Ultrasound Coronary Arteries Finding Sites</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_525758f3-f8e3-43f3-9018-cb62d0e6c565">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_414da97d-43ef-459b-b679-b06e5f511c62">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ca09eea-46bd-47e8-9d1a-63cec3d19a37">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e22410c2-afdd-40c0-933c-09d0dc90847a">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1690f2e8-f1bb-4afd-b63e-89bd932d4942">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c98158dd-f0f0-408f-89d9-9b0a891792c0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_974d1698-9e04-46c5-b30e-2e7a55ae4235">
                                <link xl:href="http://snomed.info/id/244251006" xl:show="new">244251006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a3e30378-ed46-40e3-9d93-4635c2fa59f0">Septal Artery</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0bea664-9191-44bd-b3cf-dd243f9a727c">
                                <link xl:href="http://snomed.info/id/244251006" xl:show="new">T-43002</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b19506ad-1198-4c90-8959-470a564c2bf1">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0447058" xl:show="new">C0447058</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            
            
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">
                                <emphasis role="bold">Definition</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">
                                <emphasis role="bold">Notes</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd003"><emphasis role="bold"><emphasis role="underline">ddd003</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">.</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="E" status="1" xml:id="chapter_E">
      <title>French Language Meanings of Selected Codes Used in the DCMR (Normative)</title>
      <table frame="box" label="E-1" rules="all" xml:id="table_E-1">
         <caption>French Language Meanings of Selected Codes</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_090f9188-a249-49a9-82d7-0a9851688cea">Coding Scheme Designator</para>
            </th>
               <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_238a2497-22be-41cd-af6f-3df3a3689ee9">Coding Scheme Version</para>
            </th>
               <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_0467362d-e7f7-4d4d-a1aa-8a096bbb1a7b">Code Value</para>
            </th>
               <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_b2226261-7655-49c3-a0bc-c0295572a723">Code Meaning English Language</para>
            </th>
               <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_036bfbde-f73b-46a0-883b-c655056c459f">Code Meaning French Language</para>
            </th>
            </tr>
         </thead>
         <tbody>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_72ef7485-3499-4bbd-8809-74162da52c85">SCT</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1a20cad9-b24e-40db-af0e-518d20d03394"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_0ab21771-7e43-47c3-b80c-ce7f9dddb8ac">
                      <link xl:href="http://snomed.info/id/23583003" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">23583003</emphasis></emphasis></link>
                      <link xl:href="http://snomed.info/id/409774005" xl:show="new"><emphasis role="bold"><emphasis role="underline">409774005</emphasis></emphasis></link>               
                  </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_98092cbf-de64-45c7-9ed8-da693f483614">Inflammation</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6f48ade1-0c87-402e-97ca-47b43e5fd2b4" xml:lang="fr"><emphasis role="bold"><emphasis role="strikethrough">Infection</emphasis><emphasis role="underline">Inflammation</emphasis></emphasis></para>
               </td>
            </tr>
             <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0917b47a-0e1b-4cc4-ae37-313106fd0fee">SCT</para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_05fb9972-4159-4ad2-9cc9-10a5fc2b6cdc"/>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_732c8bdc-725d-4b52-8dcf-fc7c707b027b">
                         <link xl:href="http://snomed.info/id/40020002" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">40020002</emphasis></emphasis></link>
                         <link xl:href="http://snomed.info/id/72481006" xl:show="new"><emphasis role="bold"><emphasis role="underline">72481006</emphasis></emphasis></link>
                     </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_21591916-ef09-4a2e-9a6c-23bb987d511e">Middle lobe of <emphasis role="bold"><emphasis role="underline">right</emphasis></emphasis>lung</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5be60bf9-f478-43c2-8690-6f2abfdbd37e" xml:lang="fr">Lobe moyen du poumon<emphasis role="bold"><emphasis role="underline"> droit</emphasis></emphasis></para>
                 </td>
             </tr>
         </tbody>
      </table>
   </section>
        
        <section label="F" status="1" xml:id="chapter_F">
      <title>Japanese Language Meanings of Selected Codes Used in The DCMR (Normative)</title>
      <table frame="box" label="F-1" rules="all" xml:id="table_F-1">
         <caption>Japanese Language Meanings of Selected Codes</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_0a2ebcad-b99b-4ed7-abb6-1044db248781">Coding Scheme Designator</para>
            </th>
               <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_72126191-efa7-4aef-81a7-3e4ab94ce310">Coding Scheme Version</para>
            </th>
               <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_d41965ca-6e67-4f76-80aa-514d54300e66">Code Value</para>
            </th>
               <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_799e56ce-9686-474e-98c4-b95f6d408b86">Code Meaning English Language</para>
            </th>
               <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_ed2ca850-ba13-4e52-b40a-dc809e58b83f">Code Meaning Japanese Language</para>
            </th>
            </tr>
         </thead>
         <tbody>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_3abc0e35-21dd-4e45-bcb5-34ca57dadec6">SCT</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5db0d783-1f87-4d89-84c8-6387b3f22467"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_85e2ff83-df77-4f37-8a65-3925def4e8f4">
                      <link xl:href="http://snomed.info/id/23583003" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">23583003</emphasis></emphasis></link>
                      <link xl:href="http://snomed.info/id/409774005" xl:show="new"><emphasis role="bold"><emphasis role="underline">409774005</emphasis></emphasis></link>               
                  </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_549a19e0-8eaf-4e92-ab9a-63beef0d09ef">Inflammation</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5447bfe4-f435-4412-b45e-6cf73a6597b8" xml:lang="ja">感染</para>
               </td>
            </tr>
         </tbody>
      </table>
   </section>
        
        <section label="J" status="1" xml:id="chapter_J">
            <title>SNOMED Retired Codes</title>
            
            
            
            <table frame="box" label="J-1" rules="all" xml:id="table_J-1">
                <caption>SNOMED Codes Retired from DICOM Use</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba15f948-561c-4cf6-a7c8-451b15b4d601">
                                <emphasis role="bold">Retired Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64a0b043-59fc-410d-a39e-81671a662f04">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a1e2c06a-1e64-4fd5-9ffb-0da12a76aeb2">
                                <emphasis role="bold">Replacement Code</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_246a7171-2a92-45ac-80b1-7ed33ffc877b">
                                <emphasis role="bold">Notes</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b71714a0-ad07-4114-98a2-4b9bf712262b">C-B03AA</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_141597d6-53f6-4221-bdc4-c6764947873f">Dimeglumine gadopentetate</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dbf55ecf-1371-45e5-9289-7a895179f46e">
                                <link xl:href="http://snomed.info/id/404846007" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">404846007</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/109216000" xl:show="new"><emphasis role="bold"><emphasis role="underline">109216000</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_53093118-8a88-4b82-b562-a293176d87e9">Replacement code has meaning of "Gadopentetate dimeglumine (<emphasis role="bold"><emphasis role="strikethrough">product</emphasis><emphasis role="underline">substance</emphasis></emphasis>)".</para>
                            <para xml:id="para_babcb0a7-3dbf-4d93-a34d-f9360f57234f">Retired code is inactive in SNOMED CT (Duplicate).</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/404846007" xl:show="new"><emphasis role="bold"><emphasis role="underline">404846007</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Gadopentetate dimeglumine</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/109216000" xl:show="new"><emphasis role="bold"><emphasis role="underline">109216000</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Gadopentetate dimeglumine (substance)".</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">180933005</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Fifth Ventricle</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">74968005</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning "Structure of cave of septum pellucidum (body structure)".</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">23583003</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Inflammation</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">409774005</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning "Inflammatory morphology".</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">24891006</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Sodium diatrizoate</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">No replacement code.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">277630003</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Left ventricular basal septal segment</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">No replacement code.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">277631004</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Left ventricle basal lateral segment</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">No replacement code.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">408720008</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Left ventricular posterobasal segment</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">No replacement code.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">293638001</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Allergy to X-ray contrast media</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">No replacement code.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">371951007</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Vena anonyma</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">8887007</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning "Structure of brachiocephalic vein".</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">372881000</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Vasoconstrictor</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">870406003</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning "Vasopressor".</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">373262009</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Cephalosporin antibotic</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">764147003</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning "Cephalosporin".</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">40020002</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Middle lobe of lung</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">72481006</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning "Structure of middle lobe of right lung".</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">8361002</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Intima</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">87483006</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning "Tunica intima of vessel".</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">8568009</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Abdominal lymph node</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">818991007</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning "Structure of abdominal lymph node".</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">95377006</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Injection site reaction</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">95376002</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning "Injection site disorder".</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        
    </chapter>
</book>
