<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2067</title>
    <subtitle>Add more specific tumor graft histologic types and sites</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2021/01/20</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie <link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie <link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/07/30</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2067</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add more specific tumor graft histologic types and sites</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>More specific tumor graft types and related anatomic sites are needed.</para>
                    <para><emphasis role="italic">[Ed.Note: SNOMED Request ID #753808 includes 
                        
                        254582000	Adenocarcinoma of rectum
                        76909002	Ewing's sarcoma
                        363443007	Malignant tumor of ovary
                        255046005	Neuroendocrine tumor
                        19897006	Malignant peripheral nerve sheath tumor
                        88195001	Alveolar soft part sarcoma
                        71400007	Mesothelium structure
                        61005006	Peripheral nerve myelin sheath
                        
                        ]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.16 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        <section label="CID 639" status="3" xml:id="sect_CID_639">
            <title>Tumor Graft Histologic Type</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c591c0cc-24fb-4cc0-b235-752052bae187">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_639.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_639.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_639.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1104.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_14c96ae2-a115-43f6-8b68-633f058265ff">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_9be5797b-e65c-4401-80d2-25dbe0933812">
                            <emphasis role="bold"><emphasis role="strikethrough">20200117</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a6dffa53-d938-48bb-b2ff-ee76c0b260da">
                            <emphasis role="bold">1.2.840.10008.6.1.1104</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 639" rules="all" xml:id="table_CID_639">
                <caption>Tumor Graft Histologic Type</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa3cae1e-a99b-41e4-9384-d49bdca55b0e">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12629443-4740-4e0c-b3b5-52c6a4c39da1">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c0c9761-c681-483e-9c60-c9cdb9eb4731">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a18224b3-484e-4506-9908-20b7d2de25e7">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cfaf20a9-59d4-42de-9987-fc5b2f25265a">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_235b3b40-fbd5-469f-bc1d-959b3b1ecafd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a29ff5d5-8b75-4868-9924-43ae2c928107">
                                <link xl:href="http://snomed.info/id/35917007" xl:show="new">35917007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e2b09667-6f60-4c30-9e55-b0bbae9f6a19">Adenocarcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_780ffaf3-b945-4d31-9655-d8c9bcf65a1d">
                                <link xl:href="http://snomed.info/id/35917007" xl:show="new">M-81403</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8495ecbe-7644-415a-89e4-3d57bb64437c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0001418" xl:show="new">C0001418</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3dc63561-f3ab-4f1a-bcda-71db9499bdaa">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc9ef4ef-3f62-48cd-bfaa-487df554d7ed">
                                <link xl:href="http://snomed.info/id/408645001" xl:show="new">408645001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_98906a55-a780-4b3b-a8fb-71e814451e3f">Adenocarcinoma of large intestine</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4607399-4e98-4b1e-89b4-c06eab516e80">
                                <link xl:href="http://snomed.info/id/408645001" xl:show="new">DF-00736</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a6f8666-fae7-4b27-a5a2-b42eff201717">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1319315" xl:show="new">C1319315</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93370c38-a6a5-475c-baad-699abc871a7d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f6e291f-74dd-4d97-aa23-46e14ac32244">
                                <link xl:href="http://snomed.info/id/254626006" xl:show="new">254626006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_229bf2c1-cf3f-4577-832f-f87dd3850687">Adenocarcinoma of lung</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e8532fac-b7f5-4617-ab40-dcd38efe1e48">
                                <link xl:href="http://snomed.info/id/254626006" xl:show="new">D2-F1105</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6739d66e-e437-497a-b8c2-b327bead7c4c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0152013" xl:show="new">C0152013</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a5e86cb-e8bc-4380-ad41-71a6dad90ec5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a4d663d8-32c7-4229-be09-ed00a193a7e9">
                                <link xl:href="http://snomed.info/id/700423003" xl:show="new">700423003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4b95e70b-a23e-4bd1-990e-1d1a8c3bbe89">Adenocarcinoma of pancreas</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6711f1cf-e970-4bfe-8f67-6d99aa722cde">
                                <link xl:href="http://snomed.info/id/700423003" xl:show="new">R-FB79B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d478fbe8-23e7-4587-9e09-94987d0e3856">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0281361" xl:show="new">C0281361</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/254582000" xl:show="new"><emphasis role="bold"><emphasis role="underline">254582000</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Adenocarcinoma of rectum</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/254582000" xl:show="new"><emphasis role="bold"><emphasis role="underline">D5-F1404</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0149978" xl:show="new"><emphasis role="bold"><emphasis role="underline"><emphasis role="bold">C0149978</emphasis></emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/88195001" xl:show="new"><emphasis role="bold"><emphasis role="underline">88195001</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Alveolar soft part sarcoma</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/88195001" xl:show="new"><emphasis role="bold"><emphasis role="underline">M-95813</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0206657" xl:show="new"><emphasis role="bold"><emphasis role="underline"><emphasis role="bold">C0206657</emphasis></emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b900219a-3f04-4caa-949d-a337ccc01282">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f35a9cc1-2927-4f63-9b9f-297faaa9bd2c">
                                <link xl:href="http://snomed.info/id/70594002" xl:show="new">70594002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c391528d-efee-4dc2-b864-5a4775a5cb42">Amelanotic melanoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd1fe16d-847b-4f5b-b321-32f767e6072d">
                                <link xl:href="http://snomed.info/id/70594002" xl:show="new">M-87303</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ed6791e-3c26-4499-b48f-5ddab6b8057a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0206735" xl:show="new">C0206735</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a5904cc-573e-4808-ab0b-5b48bdabcf7d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0ceba05-f607-4194-8010-d51eae317eb8">
                                <link xl:href="http://snomed.info/id/38713004" xl:show="new">38713004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_709b8033-2a84-4ce3-929d-f02450eb7595">Astrocytoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3470a9a-f7f2-4635-8f55-fbfa694caec6">
                                <link xl:href="http://snomed.info/id/38713004" xl:show="new">M-94003</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_65db04fa-ef3c-48d9-a7c8-e03ee898c06d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0004114" xl:show="new">C0004114</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_206ad659-6743-4eb7-a53c-41b3dde6a760">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f604f7f8-9981-445b-9ea5-0e24803fba93">
                                <link xl:href="http://snomed.info/id/399326009" xl:show="new">399326009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8cd1c283-e3c7-44db-84b5-d7129820be14">Bladder cancer</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f2e5a59-42fc-4011-9cb6-01988949d7e7">
                                <link xl:href="http://snomed.info/id/399326009" xl:show="new">D7-10012</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c3db537a-16e6-41e9-97e7-bd3e65efeddb">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0005684" xl:show="new">C0005684</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ce82f638-27bc-468c-b299-b2293da3c23c">NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_622570a4-6b19-46d6-b881-054db99fde3c">
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C2923" xl:show="new">C2923</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cf9dad31-b6c7-44f0-b7ed-cf9bf6b4e845">Bronchioloalveolar adenocarcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9baef9fb-32a2-4b45-865c-425928e1d78a"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a6a3dae-3e02-4a04-b1c0-2530fa1b035b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007120" xl:show="new">C0007120</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e995ce78-e9de-4eda-b39c-1a96fee15bd1">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2fcfb1a-9ddf-4fd4-8254-5f6e36b2204e">
                                <link xl:href="http://snomed.info/id/363354003" xl:show="new">363354003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_53b330c9-7c29-475c-809a-db434a719c1d">Cancer of cervix</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a2e61354-ba16-46c3-94e2-d48934e7d5d8">
                                <link xl:href="http://snomed.info/id/363354003" xl:show="new">DF-0040E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1f85dc68-5454-4cbc-9f59-b62920b4a67a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4048328" xl:show="new">C4048328</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1f1c1796-527b-40fc-a1c3-909658c264f3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0ac6f73-c7d0-4e73-b3c8-d8645d327dcb">
                                <link xl:href="http://snomed.info/id/363406005" xl:show="new">363406005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2b6d7dfd-b517-4889-b5b3-3bfad65252e7">Cancer of colon</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b0b1899-13d1-417f-902a-dc69c0c4a8c4">
                                <link xl:href="http://snomed.info/id/363406005" xl:show="new">DF-0044A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_67d6cb91-775a-48ac-99ed-3a555f0c39e3">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007102" xl:show="new">C0007102</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_49bcd01e-6160-4df3-9f07-626395587848">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c885e62e-fb9c-4aa7-8768-d31554063658">
                                <link xl:href="http://snomed.info/id/255072001" xl:show="new">255072001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_52cd530b-c3c6-4daf-858a-4c9145fb6cf0">Cancer of salivary gland</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c1e0239-6be5-466c-a640-0661c83a8a85">
                                <link xl:href="http://snomed.info/id/255072001" xl:show="new">D5-20002</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5185c090-d2ac-43e2-8093-5abbc6985842">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0220636" xl:show="new">C0220636</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d288eef-9a0d-4c43-bf32-63f3023d45cf">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_866da144-d9c0-41ef-85b6-ba9b761266d0">
                                <link xl:href="http://snomed.info/id/68453008" xl:show="new">68453008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3b9c0205-cebe-487a-b663-f609dd3a850c">Carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3be4a85d-efdd-4050-9ab1-f2a2d220e28b">
                                <link xl:href="http://snomed.info/id/68453008" xl:show="new">M-80103</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_898f7e33-d7f6-4b19-8909-2f0c5c92f647">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007097" xl:show="new">C0007097</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_064f62c5-7fd7-417e-ab79-902772c07e42">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53be619b-5df6-4104-bf7b-e191b96c2fac">
                                <link xl:href="http://snomed.info/id/63264007" xl:show="new">63264007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4dc0220c-8531-4a4d-87af-815b1073e89e">Carcinosarcoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8b1be550-0a55-4ce3-a7fb-575d768fae1a">
                                <link xl:href="http://snomed.info/id/63264007" xl:show="new">M-89803</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83e85ac8-80dc-429c-a633-3c306edbe1dc">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007140" xl:show="new">C0007140</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_368153e4-aa2d-44ef-97d4-f1fe62afa0cf">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f14f2c7-609e-4c1e-9585-d5c6820c410c">
                                <link xl:href="http://snomed.info/id/702369008" xl:show="new">702369008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ae56a9b9-4f7b-4050-b183-9d1943d6a902">Carcinosarcoma of uterus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8516d9b-4c23-40a5-9a50-3250277619e3">
                                <link xl:href="http://snomed.info/id/702369008" xl:show="new">R-FB829</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9850a230-1b80-4979-a784-7f4abd6a0870">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0280630" xl:show="new">C0280630</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9862c314-bf13-448a-850e-81fd0ee47ca6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1f13b48e-4c8b-4332-a0aa-a864f8661314">
                                <link xl:href="http://snomed.info/id/21008007" xl:show="new">21008007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5c82a04a-07de-491c-88d9-e1cb7473c8e5">Cystadenocarcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96a39e06-b2ce-40a8-bab0-266d3cbaa565">
                                <link xl:href="http://snomed.info/id/21008007" xl:show="new">M-84403</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_138f9fa3-782d-4204-9f7d-6c24f6fc23bd">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0010631" xl:show="new">C0010631</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/76909002" xl:show="new"><emphasis role="bold"><emphasis role="underline">76909002</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Ewing's sarcoma</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/76909002" xl:show="new"><emphasis role="bold"><emphasis role="underline">M-92603</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0553580" xl:show="new"><emphasis role="bold"><emphasis role="underline"><emphasis role="bold">C0553580</emphasis></emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7d9c33b-ec90-4dc9-b86b-4917a88d66cd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff81444b-448d-4e83-ab97-2bb92771404e">
                                <link xl:href="http://snomed.info/id/703707001" xl:show="new">703707001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0ff02100-a49e-4b62-ae2e-5ff204667051">Ewing sarcoma / peripheral neuroectodermal tumor</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c4bc9dfc-278d-4594-819c-776739d594a4">
                                <link xl:href="http://snomed.info/id/703707001" xl:show="new">R-FBD63</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_443d11f6-5777-4cc1-af15-fbb0844baa8e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0684337" xl:show="new">C0684337</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/53654007" xl:show="new"><emphasis role="bold"><emphasis role="underline">53654007</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Fibrosarcoma</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/53654007" xl:show="new"><emphasis role="bold"><emphasis role="underline">M-88103</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0016057" xl:show="new"><emphasis role="bold"><emphasis role="underline"><emphasis role="bold">C0016057</emphasis></emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_570c0b0f-d8a0-4cb1-b6ff-68189c6feaa0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a700250-30d5-45d1-8d04-5d9ec4c02309">
                                <link xl:href="http://snomed.info/id/63634009" xl:show="new">63634009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f0895b40-33cf-442f-9e12-f030b7684a5f">Glioblastoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a058fe3e-24ca-4b5e-abe4-89ceb56f046a">
                                <link xl:href="http://snomed.info/id/63634009" xl:show="new">M-94403</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_abc55734-8f79-4aa7-9b15-4cc2f5462a6e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0017636" xl:show="new">C0017636</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_10180aa8-0756-4fe0-8603-8a59bb9936c1">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1241ea3-3721-420b-a770-c8d15c48a567">
                                <link xl:href="http://snomed.info/id/408643008" xl:show="new">408643008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6f04766d-1cd3-4994-9906-920a2d6f8df6">Infiltrating ductal carcinoma of breast</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44f7168a-c9e2-49e4-addc-0294759aad00">
                                <link xl:href="http://snomed.info/id/408643008" xl:show="new">D0-F0369</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ab12ecd4-fcd3-49fc-a66a-64aaf8910d5f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1134719" xl:show="new">C1134719</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8fcb3e13-6175-4885-8377-7351fdec53c8">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e78d6406-d0e2-423a-be35-f1ab922e76c0">
                                <link xl:href="http://snomed.info/id/22687000" xl:show="new">22687000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_39f8f94a-315e-4ba6-8cea-0e0b883da97c">Large cell carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fe4eccc4-9122-471a-882e-43b7f0e5a2e7">
                                <link xl:href="http://snomed.info/id/22687000" xl:show="new">M-80123</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0406973a-3ef5-4519-be67-1358b0fdf6d6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0206704" xl:show="new">C0206704</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c581407c-25e5-423d-bb7f-607bfa62ad2a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d00b0b1d-1801-4384-9750-0d9ab555f85c">
                                <link xl:href="http://snomed.info/id/93143009" xl:show="new">93143009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_db11a7a6-982f-4cc9-884b-82443438a34c">Leukemia</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e105738-5850-42e0-99b2-4e8165bc81b4">
                                <link xl:href="http://snomed.info/id/93143009" xl:show="new">DC-F4113</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9c6cc8c-bc13-4421-be2e-c6b2baecb2de">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0023418" xl:show="new">C0023418</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_35163bbf-e2a6-4750-9340-42682c84d4fd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f40d0b77-c380-422f-9f2a-4d893ac89407">
                                <link xl:href="http://snomed.info/id/93880001" xl:show="new">93880001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1690d3c5-f10f-4f53-a295-8675ef4575a7">Lung cancer</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e36c2e7-e90e-4ee0-bd5f-d08fc515c474">
                                <link xl:href="http://snomed.info/id/93880001" xl:show="new">D2-F1103</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_324bb938-a9a3-4df0-8eed-06a0f4c9a8ba">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1306460" xl:show="new">C1306460</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc943483-875b-493f-830c-e90eba6e09de">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c26f90d8-9167-43e8-bfa6-4c5210b1d3a1">
                                <link xl:href="http://snomed.info/id/62064005" xl:show="new">62064005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e936d5e9-6cc2-463a-a761-c2866889a00b">M<emphasis role="bold"><emphasis role="underline">alignant m</emphasis></emphasis>esothelioma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93747b44-5879-4156-919d-a9860ca40ca5">
                                <link xl:href="http://snomed.info/id/62064005" xl:show="new">M-90503</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1b5ee995-409d-4230-974b-c801cbd58757">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0025500" xl:show="new">C0025500</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/19897006" xl:show="new"><emphasis role="bold"><emphasis role="underline">19897006</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Malignant peripheral nerve sheath tumor</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/19897006" xl:show="new"><emphasis role="bold"><emphasis role="underline">M-95403</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0751690" xl:show="new"><emphasis role="bold"><emphasis role="underline"><emphasis role="bold">C0751690</emphasis></emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c3b9c5c4-18eb-440d-ab41-3aa0d31c17ec">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a0f9732-49a5-496d-ba75-f3c0a5d774cc">
                                <link xl:href="http://snomed.info/id/2092003" xl:show="new">2092003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2de8d846-1677-4e00-8a97-1c51211dced7">Melanoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7baa5acb-24c8-45ff-bb35-a49c72a05400">
                                <link xl:href="http://snomed.info/id/2092003" xl:show="new">M-87203</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8cfcfc58-7d38-4731-8edc-a252d353fc6d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0025202" xl:show="new">C0025202</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_07cda80b-eb77-42db-87db-4a5bbd2bac47">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a1318bcb-9527-40f4-95fc-adb0dc58bde1">
                                <link xl:href="http://snomed.info/id/253001006" xl:show="new">253001006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9cb69ebb-23df-4bcf-9177-bfc9e4c451d0">Merkel cell carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9f1d4f1b-2b93-4c4a-a09b-13165461b2fa">
                                <link xl:href="http://snomed.info/id/253001006" xl:show="new">D0-F00E0</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b2291f11-3934-45b5-9ec4-5a99cdf8730d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007129" xl:show="new">C0007129</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ae39b19-c5c5-4201-8528-73840689af66">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b88beaf3-f74b-419a-bd6d-a40784ca89c5">
                                <link xl:href="http://snomed.info/id/21326004" xl:show="new">21326004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fc7bf7bb-0c88-4eeb-aba1-b31b8880bcdb">Mixed small cell carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d8c0270-3ec0-4cca-be26-f7f77cdf3ffd">
                                <link xl:href="http://snomed.info/id/21326004" xl:show="new">M-80453</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_864ea1d1-8fc7-4f5d-a7f7-326d0c5fd325">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0334240" xl:show="new">C0334240</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/255046005" xl:show="new"><emphasis role="bold"><emphasis role="underline">255046005</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Neuroendocrine tumor</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/255046005" xl:show="new"><emphasis role="bold"><emphasis role="underline">DF-004BC</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0206754" xl:show="new"><emphasis role="bold"><emphasis role="underline"><emphasis role="bold">C0206754</emphasis></emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2c2c4b5-0c33-4125-a513-e1e3f81e1eb6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ce8689d-cb1f-46c9-9526-a247f57b33ad">
                                <link xl:href="http://snomed.info/id/128632008" xl:show="new">128632008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_54fb36e8-73cd-4b12-b47f-d27384512e17">Non-small cell carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8847b7d-1246-4087-8501-df3566ff69c5">
                                <link xl:href="http://snomed.info/id/128632008" xl:show="new">M-80463</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c889eea8-4653-4826-afc3-bd7ea4d611af">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1266002" xl:show="new">C1266002</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ea67a44-e4e8-46f6-be0c-c3b0565f83e5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d63428c9-9a5e-424a-ac05-4943dc5cd8d3">
                                <link xl:href="http://snomed.info/id/254637007" xl:show="new">254637007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1acd50ac-90f1-4c65-8527-5fededf57f40">Non-small cell lung cancer</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7386ddf-87f1-4e5c-a6f3-bee2a13a0229">
                                <link xl:href="http://snomed.info/id/254637007" xl:show="new">D2-F1007</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_25b96185-44f7-426f-ba61-82b43bf05fa4">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007131" xl:show="new">C0007131</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f470af78-03ec-4f29-a1a8-b6a0d7e83dd6">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f9cf0925-145a-463b-bae0-9935e8f70673">
                                <link linkend="DCM_130406" xrefstyle="select: nopage">130406</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8832f176-9a62-48ee-96f1-f959d1b502ba">Non-uterine leiomyosarcoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fd1209f3-ee92-419f-b45c-46250c545dc3"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2260612-4e18-42a1-80cf-cd56c8ffc2ea"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c249e385-8f1b-4386-a62a-7c2e6dcecd88">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6fcbfa63-9399-40c0-bf5a-b8a7ab7284d4">
                                <link xl:href="http://snomed.info/id/21708004" xl:show="new">21708004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aa119214-0a08-4810-ab1c-2af1bd8f042e">Osteosarcoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c4183ef-c318-4913-8558-75ca246521e0">
                                <link xl:href="http://snomed.info/id/21708004" xl:show="new">M-91803</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6eb74e3d-db2f-4709-86fb-488de626d68d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0029463" xl:show="new">C0029463</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/363443007" xl:show="new"><emphasis role="bold"><emphasis role="underline">363443007</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Ovarian cancer</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/363443007" xl:show="new"><emphasis role="bold"><emphasis role="underline">DF-0046D</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1140680" xl:show="new"><emphasis role="bold"><emphasis role="underline"><emphasis role="bold">C1140680</emphasis></emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2fc951e3-ad13-4e9b-889e-33f67553b256">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d62d798e-fdb3-47dd-9fbb-37f72fb191b3">
                                <link xl:href="http://snomed.info/id/255029007" xl:show="new">255029007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b9b1917c-93c7-4b3f-ab86-99638bbd2abb">Papillary thyroid carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_911eae98-bad9-4a02-bec3-fb846920e7f2">
                                <link xl:href="http://snomed.info/id/255029007" xl:show="new">DB-F0107</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_72e31280-9fa3-47d8-90a2-5c09ae9a2f21">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0238463" xl:show="new">C0238463</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8bf90370-3e45-45ff-a086-3c0202f345bd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1ef3d95-6ba8-4851-b78a-fc4a2d8853e8">
                                <link xl:href="http://snomed.info/id/702391001" xl:show="new">702391001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_603facce-a09c-4625-807b-40d9a3166347">Renal cell carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4b5829b-ec75-44d0-aa6e-ff4e6354424d">
                                <link xl:href="http://snomed.info/id/702391001" xl:show="new">R-FB83F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b12f9e8-c324-477f-a182-b1eca6d14315">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007134" xl:show="new">C0007134</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4302682a-f477-4c03-9955-7e75b61b3b5e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f09452e-eca0-4eb5-ba45-c7c5a3f73eb6">
                                <link xl:href="http://snomed.info/id/2424003" xl:show="new">2424003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e77eb2f4-4a56-4008-9c36-692ba212346d">Sarcoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e843d516-64e2-450f-bb37-40a50970a075">
                                <link xl:href="http://snomed.info/id/2424003" xl:show="new">M-88003</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3c1f5a1c-ded5-4a80-98b0-48b19ae99258">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1261473" xl:show="new">C1261473</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_33d77ec0-0031-438c-b399-8d81695bd02d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2fa2833c-9506-4103-83aa-9a989cc79d3e">
                                <link xl:href="http://snomed.info/id/424952003" xl:show="new">424952003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4e930946-5611-41c5-8127-7704e31e444c">Sarcoma of soft tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fbc3d232-d1b5-4989-add1-53e3c561c5b8">
                                <link xl:href="http://snomed.info/id/424952003" xl:show="new">DF-007B5</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_638369e2-917a-4531-bf6e-5a7581eaf70c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4551687" xl:show="new">C4551687</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c7ec500d-028b-4649-884f-79701c5261fb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_563aed2b-abfc-4283-afb4-ecbb76648b20">
                                <link xl:href="http://snomed.info/id/74364000" xl:show="new">74364000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d8e1e5fe-65fc-4b9e-a8c4-4ce1da69922a">Small cell carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8710188d-bfe6-4ccb-86b2-5ec57fe50091">
                                <link xl:href="http://snomed.info/id/74364000" xl:show="new">M-80413</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_663754c9-8e6c-4a3b-860f-d1b7ed0e4e74">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0262584" xl:show="new">C0262584</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b9a16822-e16b-4383-a515-9576b5da2121">NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6eeaccbc-9581-4b23-ba7a-de812e28bd18">
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C148457" xl:show="new">C148457</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f6152c96-d7eb-4491-85ee-ac1693cd1ca8">Soft tissue sarcoma, excluding rhabdomyosarcoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f19e5df9-59c1-4b17-91e3-e885a688b4ab"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b135694a-b6d8-49a3-98b5-2eff1711be1d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4725047" xl:show="new">C4725047</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bcd76e14-baa7-43a1-9f06-4dac778a491e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85f62a2c-0c17-4fda-86dd-0ff17eea7edd">
                                <link xl:href="http://snomed.info/id/65692009" xl:show="new">65692009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3e5dba5c-0815-4112-8bcd-18621ebaffc8">Spindle cell carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc7f23f3-37ba-41b2-923f-33f0cb220eb0">
                                <link xl:href="http://snomed.info/id/65692009" xl:show="new">M-80323</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c656db70-2623-479d-9d3f-f36ee93d7be6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205697" xl:show="new">C0205697</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fbe775fc-cd5a-451c-aa15-824828edd125">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c10dc82-2e96-4713-b542-737177508ad3">
                                <link xl:href="http://snomed.info/id/28899001" xl:show="new">28899001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f165a014-6f4a-4088-925a-57272fe47e90">Squamous cell carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9b5eaef2-cd5a-442e-becb-16175462ec69">
                                <link xl:href="http://snomed.info/id/28899001" xl:show="new">M-80703</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_35f3c423-679a-462e-af94-7b30bb2a578c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007137" xl:show="new">C0007137</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b4405fe8-a562-4846-9dd1-9e0be1248386">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59369e4d-b755-4a72-97e7-d455fa3d7602">
                                <link xl:href="http://snomed.info/id/723265000" xl:show="new">723265000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8832a6a1-fb72-48f3-a051-6de1ff3ccfcc">Squamous cell carcinoma of anus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3315703d-46ec-4a67-af90-ef8496ccd6ae"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_16566042-182b-41fb-8cb1-3f14abb11866">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4301961" xl:show="new">C4301961</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2114fb5b-77c6-48ee-a2c5-41ff0542fa31">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8e0dc5db-63ff-4682-941b-bd0e97051682">
                                <link xl:href="http://snomed.info/id/723265000" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">723265000</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/716659002" xl:show="new"><emphasis role="bold"><emphasis role="underline">716659002</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_62e83cad-273e-49e4-be52-18d857ec8516">Squamous cell carcinoma of head and neck</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e31f62b-b8b6-4f61-b741-4a22e61a228d">
                                <link xl:href="http://snomed.info/id/723265000" xl:show="new">R-FF982</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_02313676-027f-4fa9-b635-924db20299d5">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1168401" xl:show="new">C1168401</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bf2830f1-c5fb-4a94-835f-4ad2979a044c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0d4d93da-fc1c-4c3f-82e4-5290bb1cbc78">
                                <link xl:href="http://snomed.info/id/707357005" xl:show="new">707357005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a21e30d7-7f16-4266-a5d7-2956aeb0bb83">Squamous cell carcinoma of laryngeal cartilage</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_252604a1-4d87-4ae1-8151-9bb0ad78d0ba">
                                <link xl:href="http://snomed.info/id/707357005" xl:show="new">R-FC628</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_334a922f-bf41-4959-9698-050f7c8bc7a6">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C3873422" xl:show="new">C3873422</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3bb74bb4-81c3-4fdf-a8c3-d8da301b2ed0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6019c772-a700-4150-8d19-d6b89e1f965c">
                                <link xl:href="http://snomed.info/id/254634000" xl:show="new">254634000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f9734dbe-2246-44b7-8d2e-c830e9b72582">Squamous cell carcinoma of lung</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad1d0fe2-b8cf-46a3-8223-8a001d7454d4">
                                <link xl:href="http://snomed.info/id/254634000" xl:show="new">D2-F110E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82051943-6369-47f1-9c69-f68faeaceb45">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0149782" xl:show="new">C0149782</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3f72662-752a-4dc3-a519-fb73dd61de3a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef95db7d-8de1-46ab-9092-b553bc1f51de">
                                <link xl:href="http://snomed.info/id/307502000" xl:show="new">307502000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_561f0646-8f78-4921-8d53-82efeb108bef">Squamous cell carcinoma of mouth</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_67a8bc02-520e-4ea0-8e29-2eda0c91ac2f">
                                <link xl:href="http://snomed.info/id/307502000" xl:show="new">D5-F0519</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2fb6b148-5cf8-40d3-881d-40211343ecf5">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0585362" xl:show="new">C0585362</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4192000-753b-426e-8eb7-6147756d921d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ba2c02a-799f-4949-b956-64637319aab3">
                                <link xl:href="http://snomed.info/id/254651007" xl:show="new">254651007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ca2765e7-f670-4bc8-892a-4598622d1aae">Squamous cell carcinoma of skin</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6278811-61a2-4000-9920-497fed8f02ae">
                                <link xl:href="http://snomed.info/id/254651007" xl:show="new">D0-F0005</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9f4a69db-8ddf-4c35-91e9-5f057e21d7cf">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0553723" xl:show="new">C0553723</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_256960a1-150b-40c2-a9ac-668076de0e99">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d6d27b66-b210-431e-8ea1-5132edd787f4">
                                <link xl:href="http://snomed.info/id/27090000" xl:show="new">27090000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b0da824f-2668-4409-a991-5f8f9419cee4">Transitional cell carcinoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ee600b4-c740-4bdc-b272-fe74a131404f">
                                <link xl:href="http://snomed.info/id/27090000" xl:show="new">M-81203</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c4392dd4-8086-4fe9-989c-2d59565136e5">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007138" xl:show="new">C0007138</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
<section label="CID 645" status="3" xml:id="sect_CID_645">
            <title>Exogenous Substance Tissue of Origin</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_bf06037b-6772-41d1-92a0-16a00114d9e2">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_645.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_645.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_645.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1110.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_4f10a4e4-4018-4106-9d44-ec0d9aae3afa">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_8cbd2686-dca2-4a72-9515-79075407eff1">
                            <emphasis role="bold"><emphasis role="strikethrough">20200117</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_54b927fc-eaa6-4986-8d6b-62a56f4783b8">
                            <emphasis role="bold">1.2.840.10008.6.1.1110</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 645" rules="all" xml:id="table_CID_645">
                <caption>Exogenous Substance Tissue of Origin</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d4b688b-5b92-4753-9a07-b0a316c2c945">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2080d0f9-eeb0-45ac-8ee7-1716d15e5ee9">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9a2f8e3f-3c2c-4707-b916-e412689db89f">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ab35f19-d207-4850-8257-7e26327bda9a">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46e230cb-0579-45c9-9d5c-0a41b09932e1">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6d517aa-7fe6-48f7-85b4-093b72070cd6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9de90b3-e741-4f31-9dc5-58c4452c3dff">
                                <link xl:href="http://snomed.info/id/53505006" xl:show="new">53505006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_034d740d-857b-462e-a7e0-dc60fdc514f1">Anus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_808feb40-c853-4925-87c4-cefadaf19ff5">
                                <link xl:href="http://snomed.info/id/53505006" xl:show="new">T-59900</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dfdf1a6b-513e-4145-a2d4-cf1c86723e5a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0003461" xl:show="new">C0003461</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58318a93-9c64-4752-b2e0-b547841924ad">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c926f3a-6a4d-4d4d-9ea6-c4150e93bba7">
                                <link xl:href="http://snomed.info/id/409615008" xl:show="new">409615008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_55c5d09d-dc93-4faa-970f-e94d60986b0a">Ascitic fluid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37e43d0c-bfc1-4731-9597-2a7590ac2168">
                                <link xl:href="http://snomed.info/id/409615008" xl:show="new">T-D04AC</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_977362c4-be76-4188-bae4-cfa55fd5675a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0003964" xl:show="new">C0003964</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0b2bc0b5-4749-4782-947a-37cba2848ae3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_94bcf79c-b0cd-4fc5-8f7b-1497f54df784">
                                <link xl:href="http://snomed.info/id/89837001" xl:show="new">89837001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6f80395c-0ae0-4e71-af5d-213b28d4c687">Bladder</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd0ba399-5c85-4b9e-9031-2ede36c5fdab">
                                <link xl:href="http://snomed.info/id/89837001" xl:show="new">T-74000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d378e27-5423-47d2-aa3c-8040b034a4dc">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0005682" xl:show="new">C0005682</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90f439e6-d833-4fe6-be85-e6b8a56372f0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d95f9646-29e2-4148-9039-4b6eb259386f">
                                <link xl:href="http://snomed.info/id/272673000" xl:show="new">272673000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b4cbabfd-5fc5-4ef8-9005-682ae3a99de7">Bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7195945c-981f-406c-80ee-6b6cca181414">
                                <link xl:href="http://snomed.info/id/272673000" xl:show="new">T-D016E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_65325a46-a4e0-4beb-bd78-5eee7ee94d75">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0262950" xl:show="new">C0262950</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_494d36e6-0c26-495d-9899-459e686a5c90">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d392e087-53e9-476c-85d2-7d1041ca76af">
                                <link linkend="DCM_130407" xrefstyle="select: nopage">130407</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a31b0e58-78b3-4f72-b0ed-868a5ba3f157">Bone and soft tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ab3cccb-34bb-42ca-a07a-51d7176ad3c1"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86028394-a09c-476a-b8db-0cbba4a9b43f"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c544c59-0d7a-4661-bc36-8e808bef8e42">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80204506-4697-4ddd-ab1b-8faf9346219d">
                                <link xl:href="http://snomed.info/id/12738006" xl:show="new">12738006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_22ab1c40-96ac-4489-935d-1b062b8ef4c4">Brain</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_816c53e0-ae37-4bf0-a542-0e58aa3dc27a">
                                <link xl:href="http://snomed.info/id/12738006" xl:show="new">T-A0100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c14877f-3625-401e-845d-92a20f0fed2d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0006104" xl:show="new">C0006104</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1eb650b2-0396-4148-8f20-bf95720573cb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96961ae1-e329-4e7f-9bec-8967d6889044">
                                <link xl:href="http://snomed.info/id/76752008" xl:show="new">76752008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bf2f8b2b-0b4c-4ad4-9c61-e01327911261">Breast</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ce1d2f5-5675-46e8-8b7d-3b54aca535aa">
                                <link xl:href="http://snomed.info/id/76752008" xl:show="new">T-04000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3fc6e7c4-c555-4659-bf83-27ffa6b2852a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0006141" xl:show="new">C0006141</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50888de6-94ab-4681-a7a2-e747d6c129c5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85d78a23-07c0-41fc-964d-aacc7ae5ef9c">
                                <link xl:href="http://snomed.info/id/21483005" xl:show="new">21483005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_855242c7-5688-4218-ab78-5527b3c8a0ae">Central nervous system</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50cf7707-6e51-4cf7-9f2b-6aaab957afb0">
                                <link xl:href="http://snomed.info/id/21483005" xl:show="new">T-A0090</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9fc16f3e-f644-4ffc-9260-2520fd572807">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0927232" xl:show="new">C0927232</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_72ce86d9-08a2-41ad-8a6e-960c1d0555c4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df32b9dc-865b-4fd6-896f-fb12051321a6">
                                <link xl:href="http://snomed.info/id/71252005" xl:show="new">71252005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_426276fc-6600-4b87-adf1-779861b5b5ab">Cervix</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da0733a8-196b-4b6a-b4e4-0df61369d99c">
                                <link xl:href="http://snomed.info/id/71252005" xl:show="new">T-83200</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04af7159-6408-41c4-8e48-75031f026c9d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0007874" xl:show="new">C0007874</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_662f638f-453e-422d-bfaa-cd813c50a670">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9aa53573-b126-480d-936c-ce203660325a">
                                <link xl:href="http://snomed.info/id/71854001" xl:show="new">71854001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6965b21f-3714-4900-a6ac-6b2da2791dbb">Colon</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5191aca7-2dbe-4598-88d9-f374bf7b342e">
                                <link xl:href="http://snomed.info/id/71854001" xl:show="new">T-59300</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aaa53c2-00d5-4e5a-a9e6-f08384685d0e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0009368" xl:show="new">C0009368</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_31c930d5-ebfa-4920-a3e2-e733f72dd344">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_74d4a5f9-4afb-4a52-99e4-5ba5818559bf">
                                <link xl:href="http://snomed.info/id/21793004" xl:show="new">21793004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ac03cb59-72a6-4f94-85b3-ecbf48f60c0d">Connective tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96c60215-96b8-40f3-a3c1-94717d75423e">
                                <link xl:href="http://snomed.info/id/21793004" xl:show="new">T-1A200</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63ec817d-1be6-4380-8fbe-95456a80afe0">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0009780" xl:show="new">C0009780</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7dcd662-7f15-4658-866c-58667f6803b8">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7797b0ba-bc64-4190-8e6c-df281621468b">
                                <link linkend="DCM_127801" xrefstyle="select: nopage">127801</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6054df7b-6bc8-491b-b0fc-fe1851f8b60c">Embryonic kidney</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7bbc6110-df80-4cf6-80ac-6f6b33895c80"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9117e015-2ca3-4807-adc6-c871337f2a47"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a14daa90-7094-4fcc-9c0b-6b03e55caaa9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_084f2c52-62e9-4e4d-8789-3f9fd3f78af1">
                                <link xl:href="http://snomed.info/id/774007" xl:show="new">774007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2f3c2f11-f753-47e9-9d31-3a707deb03a4">Head and neck</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90d69523-7244-440b-a65a-f903f6bd34d3">
                                <link xl:href="http://snomed.info/id/774007" xl:show="new">T-D1000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0b8d2d4-c3b9-492e-8c1c-96ee63d14623">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0460004" xl:show="new">C0460004</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_305ed0c9-eb50-4ce1-9f28-74c2caf8caf9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0191baed-0993-4437-8af3-f7c672348d8f">
                                <link xl:href="http://snomed.info/id/64033007" xl:show="new">64033007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_819aebb3-5cfb-43e1-8f50-7f93fcb0fcff">Kidney</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53ea3e82-7c64-4275-9940-5d7f49ea31e5">
                                <link xl:href="http://snomed.info/id/64033007" xl:show="new">T-71000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_461872fe-bba3-414d-825e-ea5b871585f5">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0022646" xl:show="new">C0022646</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b1acb17b-342a-4b93-b838-d1d0384666af">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0539de95-71d8-4d58-8ea8-b945b7b0284c">
                                <link xl:href="http://snomed.info/id/4596009" xl:show="new">4596009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3171ba77-20a0-42ed-b505-761e522fc5ff">Larynx</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8e13d0e-0141-4c7f-b8ee-6a528888ce0e">
                                <link xl:href="http://snomed.info/id/4596009" xl:show="new">T-24100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70d01ac7-f626-44ac-a880-b3cba031a09d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0023078" xl:show="new">C0023078</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc3f8869-69f7-46e6-8416-cf2f66e59b39">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d4453a8-1f24-46ad-b3e0-85495f6e4478">
                                <link xl:href="http://snomed.info/id/39607008" xl:show="new">39607008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_83d2a74e-2a38-4380-a6a9-515f0296886f">Lung</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa59518c-a6ac-4c49-85ae-a8e3f1806802">
                                <link xl:href="http://snomed.info/id/39607008" xl:show="new">T-28000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8fd1b845-48ff-465c-8e18-3959be650f30">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0024109" xl:show="new">C0024109</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3317b934-70b4-4f7c-a7a5-28f8e73d318b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af3e46d1-07ad-431c-837e-52b0c8b4a9b3">
                                <link xl:href="http://snomed.info/id/38000004" xl:show="new">38000004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_77bfcc79-5d8a-4435-9f7e-fd32c827fb00">Lymph</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d90ccc5d-4e8f-4d63-bd8c-f9961a720713">
                                <link xl:href="http://snomed.info/id/38000004" xl:show="new">T-C6020</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_05f614a0-7e17-4af8-98ee-8fabaf17c20b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0024202" xl:show="new">C0024202</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c00dc3da-24a2-40bc-88a6-a470f4c09e18">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c18a919c-b1a6-4965-95ce-a4188bf729a1">
                                <link xl:href="http://snomed.info/id/181768009" xl:show="new">181768009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b8b887ce-102c-4e39-8d83-52d6c29860ef">Lymphatic tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_05a4fd82-7941-4903-8957-5d0a9541ae23">
                                <link xl:href="http://snomed.info/id/181768009" xl:show="new">T-D03C2</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f789d5cc-ff9c-4b4b-9b34-65daaee6413c">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0024296" xl:show="new">C0024296</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40ae4471-d48b-4552-9017-9f05d0a928f6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3168e28-4ea1-45c6-bbba-36cfdf97cc0d">
                                <link xl:href="http://snomed.info/id/59441001" xl:show="new">59441001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_55b57ecf-d7b8-42be-b148-443afdadd59f">Lymph Node</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_651b4d16-232c-4ede-89cf-24723ab574be">
                                <link xl:href="http://snomed.info/id/59441001" xl:show="new">T-C4000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c8292a6-85e9-4266-ab52-e34c6fa97424">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0024204" xl:show="new">C0024204</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/71400007" xl:show="new"><emphasis role="bold"><emphasis role="underline">71400007</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Mesothelium</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/71400007" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-1A120</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0086610" xl:show="new"><emphasis role="bold"><emphasis role="underline"><emphasis role="bold">C0086610</emphasis></emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_571ae894-aff3-49ea-99e1-23d7253c0c32">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6849705-1622-43d8-8db8-82f01c87d889">
                                <link xl:href="http://snomed.info/id/128462008" xl:show="new">128462008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_59e20696-75e1-4e5c-8bbf-c312e96af278">Metastasis</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7fd8e3c-10bb-42e8-8ef7-84490d296781">
                                <link xl:href="http://snomed.info/id/128462008" xl:show="new">DF-00436</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fab02487-c50f-4d33-9255-043e26a7bcd3">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2939419" xl:show="new">C2939419</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6bc83669-a9aa-457f-86f5-727088bc4df6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac90341e-7f8a-48ca-8cc9-0bbcd192d248">
                                <link xl:href="http://snomed.info/id/123851003" xl:show="new">123851003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1e5bc6e0-0999-4fc7-ad94-10d90d132a6f">Mouth</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_152eb419-0537-4113-92be-86aaea1f74dd">
                                <link xl:href="http://snomed.info/id/123851003" xl:show="new">T-D0662</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_815bd4c8-9101-4a5c-9cba-4615117fee3d">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0230028" xl:show="new">C0230028</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2e37e02-9827-4a32-a2b1-734171df0d50">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2b238e30-327f-413a-85e5-38ae76102165">
                                <link xl:href="http://snomed.info/id/15497006" xl:show="new">15497006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cf46265b-4cae-4f67-9fdb-8ea7f0ff8e9b">Ovary</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_414b9cc3-23ea-4cb8-a032-cef187f75866">
                                <link xl:href="http://snomed.info/id/15497006" xl:show="new">T-87000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_74aa313b-7968-4bcd-88bd-8f5e9bde1ad7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0029939" xl:show="new">C0029939</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0b13e5c6-57e9-420e-86d5-a652bc2575c9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_478abe20-8a8a-4409-962a-b6e4886dc88c">
                                <link xl:href="http://snomed.info/id/15776009" xl:show="new">15776009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_386fd957-fe1d-46a0-8d51-e3d30858cc41">Pancreas</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_71414420-9805-4841-873a-313f9bf2aa78">
                                <link xl:href="http://snomed.info/id/15776009" xl:show="new">T-65000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82e4ff59-fb79-40af-aa0d-e5de26aa8a5a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0030274" xl:show="new">C0030274</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/61005006" xl:show="new"><emphasis role="bold"><emphasis role="underline">61005006</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Peripheral nerve myelin sheath</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/61005006" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-A0610</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0228098" xl:show="new"><emphasis role="bold"><emphasis role="underline"><emphasis role="bold">C0228098</emphasis></emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0bfc98ce-5e06-43e8-bfa2-a3ba81e18dc0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_651c32eb-1938-43b2-98d0-851464dd5be5">
                                <link xl:href="http://snomed.info/id/60046008" xl:show="new">60046008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fb435c05-57e5-40fc-b265-577b9bf445b9">Pleural effusion</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc79fa40-e2d6-4d0d-b672-36c24e0f0da7">
                                <link xl:href="http://snomed.info/id/60046008" xl:show="new">D2-80100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93d4173a-6115-4cbf-b0b1-228a96f6263b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0032227" xl:show="new">C0032227</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b0bafd8-bcf2-4abc-ad47-32068aad8adf">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5f954c37-4cd0-49d8-b836-e4823a5793ac">
                                <link xl:href="http://snomed.info/id/41216001" xl:show="new">41216001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cc5d0f84-952e-4f5f-8ff2-3f335394f7e6">Prostate</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7561142-77ee-4f00-9168-e74398797e98">
                                <link xl:href="http://snomed.info/id/41216001" xl:show="new">T-92000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e8c7d203-e4da-416f-92b5-e6ec5cfc294a">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0033572" xl:show="new">C0033572</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e67ba51c-cf58-4c84-b54b-45a2d2880662">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1fbe8ded-985c-4bf8-b0ff-6051c4a143a0">
                                <link xl:href="http://snomed.info/id/94391008" xl:show="new">94391008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8a63c9bd-c232-426f-acab-5e346d996e44">Pulmonary metastasis</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ecea04ad-47fa-44d0-9d89-c0a0f7805aa5">
                                <link xl:href="http://snomed.info/id/94391008" xl:show="new">D2-F1106</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf6a5e96-6768-4baa-8fd4-1ce0f8c6b7ce">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0153676" xl:show="new">C0153676</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/34402009" xl:show="new"><emphasis role="bold"><emphasis role="underline">34402009</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Rectum</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/34402009" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-59600</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0034896" xl:show="new"><emphasis role="bold"><emphasis role="underline"><emphasis role="bold">C0034896</emphasis></emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2c14551-8675-48a6-a324-d473b660f6de">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a91b14d-527f-457b-b1bc-90d7bf1766eb">
                                <link xl:href="http://snomed.info/id/385294005" xl:show="new">385294005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e664cc7d-3c8e-4f62-8d31-983897ada8e4">Salivary gland</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6528b862-62c0-460a-a35a-05f04aa21885">
                                <link xl:href="http://snomed.info/id/385294005" xl:show="new">T-61007</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f00ac90a-12b1-4585-9d16-7700af1d48c4">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0036098" xl:show="new">C0036098</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8470f051-d3d5-4466-bc18-cb6f4f9be5c5">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53e34218-c2ab-475b-9195-787bc9e82ff8">
                                <link xl:href="http://snomed.info/id/39937001" xl:show="new">39937001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1ec5e375-dfb6-4e54-91ae-ac997c872385">Skin</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_faf9dc34-dff5-4dc7-bff9-931d7f4092b8">
                                <link xl:href="http://snomed.info/id/39937001" xl:show="new">T-01000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_05030aa6-2122-4990-94be-3a286845263b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0221911" xl:show="new">C0221911</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e031ce1-726b-4fc2-aa0a-183961de9858">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bfcd5a73-acef-48b0-8a9f-ebd201566774">
                                <link xl:href="http://snomed.info/id/87784001" xl:show="new">87784001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_07e113cd-ac90-4d2c-9b9a-a705f0dcc8a4">Soft tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9993643-f360-4e82-8c1d-45724d2b53a8">
                                <link xl:href="http://snomed.info/id/87784001" xl:show="new">T-1A000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d76ab800-39c1-4795-87d3-a77d13182525">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0225317" xl:show="new">C0225317</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c4bf7124-435b-4fdb-9f63-2d90675369c4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_05673468-645c-437f-9be1-9305bcf4ea2b">
                                <link xl:href="http://snomed.info/id/69748006" xl:show="new">69748006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cddc81f7-cbbc-42c1-b0ea-306ac573c18f">Thyroid</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c260a266-d7ab-4e53-8170-4ec6b2e8a46e">
                                <link xl:href="http://snomed.info/id/69748006" xl:show="new">T-B6000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f6fcb1f-c8da-4c31-85a7-9b636d2eaa26">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0040132" xl:show="new">C0040132</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b30135e7-1850-4723-86f3-a9dfe69367e9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d97189e8-5d7c-4fcb-9023-f163e74069b8">
                                <link xl:href="http://snomed.info/id/35039007" xl:show="new">35039007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a6f4c14a-60a9-40ab-b09f-82e2f7a0ee18">Uterus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f453646a-58d2-4e62-82fd-65871f0c060e">
                                <link xl:href="http://snomed.info/id/35039007" xl:show="new">T-83000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_45c87327-d46d-488b-b11b-ec1b8db8a4c9">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0042149" xl:show="new">C0042149</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>        
    </chapter>
</book>
