<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2050</title>
    <subtitle>More Deidentification Data Elements</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>November 2020 Voting Packet</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/11/02</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie <link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Mathieu Malaterre <link xl:href="mailto:mathieu.malaterre@gmail.com"/></para>
                    <para>David Clunie <link xl:href="mailto:dclunie@dclunie.com"/></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/05/25</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2050</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: More Deidentification Data Elements</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.15</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The Nonconforming Modified Attributes Sequence and Nonconforming Data Element Value data elements were added by CP 1766 but were not added to the de-identification profile to be handled in the same manner as the existing Modified Attributes Sequence.</para>
                    <para>add IssuerOfPatientID UniversalEntityDeidentification</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.15 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        <section label="E.1" status="2" xml:id="sect_E.1">
            <title>Application Level Confidentiality Profiles</title>

            
            
            
            
            
            <section label="E.1.1" status="3" xml:id="sect_E.1.1">
                <title>De-identifier</title>
                
                


                
                
                
                
                
                <table frame="box" label="E.1-1" rules="all" xml:id="table_E.1-1">
                    <caption>Application Level Confidentiality Profile Attributes</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5e6e8ba-34e0-4e31-90b5-bd9ed7086ddd">
                                    <emphasis role="bold">Attribute Name</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d02d5580-8438-4a00-8c30-ba93530bcd31">
                                    <emphasis role="bold">Tag</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_705936dc-2c42-4198-b406-ba0e61b35e99">
                                    <emphasis role="bold">Retd. (from <olink targetdoc="PS3.6" targetptr="PS3.6" xrefstyle="select: labelnumber"/>)</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8387cac-386f-4ad9-96b3-b3dcb1b1010c">
                                    <emphasis role="bold">In Std. Comp. IOD (from <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>)</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc0ff9a1-5780-4d06-861a-24ae0ba38b47">
                                    <emphasis role="bold">Basic Prof.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19ddb67a-a5d6-474d-a13f-8df27d28b707">
                                    <emphasis role="bold">Rtn. Safe Priv. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b335431-5276-4cc0-bddf-93b6d107226e">
                                    <emphasis role="bold">Rtn. UIDs Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8317e0cf-0080-48f9-8040-1f49a4478c0f">
                                    <emphasis role="bold">Rtn. Dev. Id. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ba661a2-a572-420a-95c1-bc1bf694a70e">
                                    <emphasis role="bold">Rtn. Inst. Id. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_796841da-6b27-4558-99c9-99503edccc6c">
                                    <emphasis role="bold">Rtn. Pat. Chars. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edac8181-290b-4f9c-945d-5dfc7b1a43fc">
                                    <emphasis role="bold">Rtn. Long. Full Dates Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6305752d-56e7-4f4d-b9d8-e5052fcd6eea">
                                    <emphasis role="bold">Rtn. Long. Modif. Dates Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84f3b128-8fe5-45bc-b04e-abc483377b06">
                                    <emphasis role="bold">Clean Desc. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0adc5d55-1196-4265-8ee1-b205103c96f1">
                                    <emphasis role="bold">Clean Struct. Cont. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e74e547-b6fd-410e-9c09-b271915c3eeb">
                                    <emphasis role="bold">Clean Graph. Opt.</emphasis>
                                </para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24cd2819-47c4-4216-b367-e24870678c75">Modified Attributes Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d76b4d6-34a4-4988-8968-d15fb6762beb">(0400,0550)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9752181-07fd-44c5-b57d-cb0661becccc">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bbe33cd-4d3f-4c1a-832c-072eff2e25ac">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f45c1255-b380-47f5-8729-73a338c22f21">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Nonconforming Modified Attributes Sequence</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">(0400,0551)</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Nonconforming Data Element Value</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">(0400,0552)</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        
                    </tbody>
                    
                </table>
            </section>
            
            
        </section>

    </chapter>
</book>