<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2047</title>
    <subtitle>Add Couinaud Liver Segments</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/06/15</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie <link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Harald Zachmann <link xl:href="mailto:Harald.Zachmann@ca.ibm.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/04/23</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2047</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Couinaud Liver Segments</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.6, PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Concepts are need for liver segmental anatomy for segmentation and lesion sites</para>
                    <para><emphasis role="italic">[Ed.Note. CRS Request# 752533 for 71133005,277956007,277957003,277958008,277959000,277960005,277961009,277962002]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.16 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="CID 7154" status="3" xml:id="sect_CID_7154">
         <title>Abdominal Segmentation Types</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_bb3e5735-ae54-46b6-bbae-38af15052348">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7154.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7154.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7154.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.500.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_a5cb6c30-9785-4f07-b55e-8cb259c0741a">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_1fd88322-9cc5-42b3-b3c2-ceee0fa27314">
                            <emphasis role="bold"><emphasis role="strikethrough">20200310</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f724c996-d27f-478f-91d1-f83319853bfc">
                     <emphasis role="bold">1.2.840.10008.6.1.500</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7154" rules="all" xml:id="table_CID_7154">
            <caption>Abdominal Segmentation Types</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_11991a50-7ca4-4387-8351-175c1e994971">Coding Scheme Designator</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_6a4bc776-41e7-4165-9f32-4abecc6c8dfd">Code Value</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_8e1bd18a-d3e7-4614-988d-16b0a921ccc9">Code Meaning</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_db0cf5bd-ce6e-4c1e-8506-00c7de462510">SNOMED-RT ID</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_acfe6557-f813-4aee-b6fb-3627b755d0d5">UMLS Concept Unique ID</para>
            </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_91832597-16ca-47db-a3dd-928de44f97c9">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b1454d5f-42e7-48b7-acb4-014c1140720e">
                        <link xl:href="http://snomed.info/id/113345001" xl:show="new">113345001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_db881caa-edf0-4bc6-8318-88a59d07a0b3">Abdomen</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_24a70e82-c4c2-4492-9a1e-1fc469b4b9a4">
                        <link xl:href="http://snomed.info/id/113345001" xl:show="new">T-D4000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0586751d-786b-4b97-889d-dd982b4471dc">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0000726" xl:show="new">C0000726</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8c6c2029-12e3-4984-a523-872b578e31e2">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_33383000-55cf-43e9-9544-2f94109cddee">
                        <link xl:href="http://snomed.info/id/52731004" xl:show="new">52731004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0f19c97e-45dc-4683-9666-febc9aea23fa">Abdominal cavity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bc9bf7df-989c-468d-8cc5-c57432e79381">
                        <link xl:href="http://snomed.info/id/52731004" xl:show="new">T-D4010</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d8472df1-963b-4c75-9ffc-a830bf82d9f6">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0230168" xl:show="new">C0230168</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ba55fd86-4692-49b3-ada9-55bfec130799">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a1a24c4d-24bf-4169-b4f0-dda2b07d6c4e">
                        <link xl:href="http://snomed.info/id/195879000" xl:show="new">195879000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_12266b56-c826-44c2-a267-77cc65a09547">Abdominal wall muscle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_24495fc2-3a0c-40db-92de-f90ee4ae8f45">
                        <link xl:href="http://snomed.info/id/195879000" xl:show="new">T-14001</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f5f60032-419b-4162-a0fd-e473f232b192">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1279385" xl:show="new">C1279385</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_12fc3780-b4c1-4814-aaec-8cc35a4c6dcf">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_836f1f57-71eb-42d0-a50e-42d45676ce5d">
                        <link xl:href="http://snomed.info/id/23451007" xl:show="new">23451007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f4dadc22-1c55-4e37-b335-0b251dd51d7b">Adrenal gland</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_addd9cdc-5bd5-4816-b5d9-2c8e2f559ec2">
                        <link xl:href="http://snomed.info/id/23451007" xl:show="new">T-B3000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7fded38b-75b5-47d4-931b-ec440c113d58">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0001625" xl:show="new">C0001625</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_593b4640-6f69-466c-aa02-d6761c8c97e7">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2b92b6ed-6ace-42cd-8415-2e8f2241dee1">
                        <link xl:href="http://snomed.info/id/7832008" xl:show="new">7832008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_366ce443-3d61-4f90-a740-3721ff857274">Abdominal aorta</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_107508b9-5154-4413-918b-fda915ab72ac">
                        <link xl:href="http://snomed.info/id/7832008" xl:show="new">T-42500</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_81504a0a-a69f-46f1-8582-55eb50fa3a99">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0003484" xl:show="new">C0003484</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a7e6ab33-a1b3-4c2c-86f1-5c3ed638946a">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d116b8e7-ef47-4035-834d-d75714bef395">
                        <link xl:href="http://snomed.info/id/28273000" xl:show="new">28273000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e6cea74b-1945-4494-ac17-c9e145adba47">Bile Duct</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d5c30db3-c849-446e-b3c1-751d76f464b3">
                        <link xl:href="http://snomed.info/id/28273000" xl:show="new">T-60610</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_83e3278a-6cc2-48aa-88a8-16b0316a707c">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0005400" xl:show="new">C0005400</link>
                     </para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7a1b6eaf-4f9d-4df6-9b61-71c02ab5e6de">SCT</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_13ad82ab-9ebe-48c6-9b6a-da453ae8d882">
                            <link xl:href="http://snomed.info/id/28231008" xl:show="new">28231008</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e9ed4de1-6537-4662-a7b2-96c41c374c39">Gallbladder</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b427bd13-f078-4cec-9f21-5b6c8bf5a4a9">
                            <link xl:href="http://snomed.info/id/28231008" xl:show="new">T-63000</link>
                        </para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_69bc4295-0aad-46cc-bb27-7437e77d9250">
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0016976" xl:show="new">C0016976</link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e6ea6d83-9c67-4547-8c69-f0ce5882733c">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_48d015b9-5e6a-4100-b737-a517546607f6">
                        <link xl:href="http://snomed.info/id/64131007" xl:show="new">64131007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_32611fa7-62a4-4d0b-8803-7364f35eb086">Inferior vena cava</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f4582552-b95d-4512-a722-dbf73630da6d">
                        <link xl:href="http://snomed.info/id/64131007" xl:show="new">T-48710</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4b6d8f78-d344-4479-b3a9-6012c7406cbd">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0042458" xl:show="new">C0042458</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f060f01f-08fd-4c27-9e4d-c7c940cf735b">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7ed9ce76-b0d5-40b2-b521-0684b2cc2de0">
                        <link xl:href="http://snomed.info/id/64033007" xl:show="new">64033007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fabb9762-0069-4671-ab0e-49752805d6e9">Kidney</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bdb5a4f3-5296-4f32-ba0d-6bffa7acd010">
                        <link xl:href="http://snomed.info/id/64033007" xl:show="new">T-71000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9dbf913b-79c9-4c26-834e-7f345cb0e5b5">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0022646" xl:show="new">C0022646</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1fd5d5a3-dfd4-460e-bf80-182fd8e2c98a">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5730128e-48e2-4740-8849-2b78e38e8b77">
                        <link xl:href="http://snomed.info/id/10200004" xl:show="new">10200004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e5e03d0e-bd06-426e-a0db-192c34aaba40">Liver</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_eb56ec49-bf68-4ebd-aa05-962ce6e45b8d">
                        <link xl:href="http://snomed.info/id/10200004" xl:show="new">T-62000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a47a90d9-2cc8-4340-98fb-dd4fa554f7f6">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0023884" xl:show="new">C0023884</link>
                     </para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e7daab91-27f5-4f01-83f8-f04d9ee54707">FMA</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3a5106c4-08b7-45fd-9790-dff5e6a8340b">
                            <link xl:href="http://purl.org/sig/ont/fma/fma17891" xl:show="new">17891</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8f4fa1b2-6fd6-4dfa-8ca0-184a3d4e2168">Lumen of gallbladder</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_087ad489-0d59-468a-87d8-f971e0f7a063"/>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_766eb000-3ce3-4a5f-b22b-0226995bd2d4">
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0736580" xl:show="new">C0736580</link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_32f3cfe2-262f-4b64-8e9e-0cc4c441e9f6">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f4786939-06db-473f-ac68-214455fd83c1">
                        <link xl:href="http://snomed.info/id/27398004" xl:show="new">27398004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_df65816b-44c6-4363-b925-cdf691d8519a">Omentum</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7e26265e-7d42-4c1e-b432-0be6f5352e09">
                        <link xl:href="http://snomed.info/id/27398004" xl:show="new">T-D4600</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_251284ba-a82f-4ff7-9c64-508e2cfe7e7e">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0028977" xl:show="new">C0028977</link>
                     </para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_531864af-41e1-4728-b1bd-e94192f2ae88">SCT</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3922ab97-3ca9-4bf9-94f0-312063c8b49a">
                            <link xl:href="http://snomed.info/id/15776009" xl:show="new">15776009</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_946bf6ef-8ec9-409b-a3ad-0ae5afad7c81">Pancreas</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a03ac9ac-3f72-4994-9335-d03c8ca7487d">
                            <link xl:href="http://snomed.info/id/15776009" xl:show="new">T-65000</link>
                        </para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8fccdae2-5375-4767-81d1-1199a64e1531">
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0030274" xl:show="new">C0030274</link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1b37b390-bdd3-457d-b96d-c81d6c1f7c68">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0f2aa563-01a8-4b6e-8729-c044e5b42f04">
                        <link xl:href="http://snomed.info/id/83670000" xl:show="new">83670000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_bd0ae909-4c68-493e-9c3c-763289e16376">Peritoneal cavity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d2f52811-4e09-49d1-adb5-7d2de0c5a752">
                        <link xl:href="http://snomed.info/id/83670000" xl:show="new">T-D4425</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_216ecbfa-42e6-4176-90c9-502c02bc7ca0">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1704247" xl:show="new">C1704247</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f6d431bb-e555-4056-ae6f-7eb0bdcd718b">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aebc5b3d-ac50-41a7-b9a0-f21030e4939a">
                        <link xl:href="http://snomed.info/id/15425007" xl:show="new">15425007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a33540e8-528b-4b22-b7a3-8ce2f47bde76">Peritioneum</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_03e0a041-f5ee-4fde-8016-2f2ab493e437">
                        <link xl:href="http://snomed.info/id/15425007" xl:show="new">T-D4400</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_72b0377c-4d1b-4427-ac56-2b5b20da5093">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0031153" xl:show="new">C0031153</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_eebba1a7-2a46-4f22-aad7-fb110b2321e4">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ce6ecd1d-e3fa-449e-a5fa-b8c4e8142094">
                        <link xl:href="http://snomed.info/id/82849001" xl:show="new">82849001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4854ae61-cb24-47d8-b657-036e9c5317ce">Retroperitoneal space</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7e87ae1d-5b04-46c8-80dd-d235cf9171a7">
                        <link xl:href="http://snomed.info/id/82849001" xl:show="new">T-D4900</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_194d12bf-a25a-4dd1-a9ea-1dbf35fc0302">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0035359" xl:show="new">C0035359</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f07bf21d-3661-4845-98d8-4b2886a20678">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_68cef690-d6a0-41c7-a4e6-1495a9e13ce1">
                        <link xl:href="http://snomed.info/id/75093004" xl:show="new">75093004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_559e63e3-0fcb-4714-9da9-4dba5049a07f">Skin of abdomen</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dbc893f2-9a57-444a-9384-ac6ab00746c4">
                        <link xl:href="http://snomed.info/id/75093004" xl:show="new">T-02480</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bbe16263-ca35-40f8-993a-ce733f0bfd76">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0222166" xl:show="new">C0222166</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_69a38d22-5648-4aca-ab0f-cf3dc3a3f70c">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_720a109e-b216-4f25-ac7d-72311a250ce8">
                        <link xl:href="http://snomed.info/id/30315005" xl:show="new">30315005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8b31bcd3-ef0b-416f-a458-21cbc8a16bd5">Small Intestine</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c6c4e25f-f923-49fc-9dbc-06fa66103964">
                        <link xl:href="http://snomed.info/id/30315005" xl:show="new">T-58000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bfaed8af-b448-420b-999c-60de2f38143d">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0021852" xl:show="new">C0021852</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d54a34e4-80fa-42e9-8b65-77b9d50df9e8">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a765c64a-ca56-4a7d-af6d-5f425ee9a56a">
                        <link xl:href="http://snomed.info/id/78961009" xl:show="new">78961009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c20cd5e1-aef5-42fd-933d-cee5fc2ba5f2">Spleen</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_56e5baa5-2596-432e-b93b-9e11c5416279">
                        <link xl:href="http://snomed.info/id/78961009" xl:show="new">T-C3000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d3cbe266-dd78-413c-a4d4-a7c469a64cc0">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0037993" xl:show="new">C0037993</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dbe29004-4de1-48ba-8187-285e6af17eec">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d5d7c52e-56d7-48a3-aeb9-b1cafae208ac">
                        <link xl:href="http://snomed.info/id/122489005" xl:show="new">122489005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4c38e5dc-620a-4067-ae16-3b243175aba2">Urinary system</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5eb29a1f-8cb2-44c1-a719-a84173cb682b">
                        <link xl:href="http://snomed.info/id/122489005" xl:show="new">T-70001</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_62ce1d72-e214-4209-99de-9446f23af0ae">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1508753" xl:show="new">C1508753</link>
                     </para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cec73700-7af9-4e78-8218-952708cf375f">FMA</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4cedc8aa-1f8b-47e5-a7eb-909761edac37">
                            <link xl:href="http://purl.org/sig/ont/fma/fma14657" xl:show="new">14657</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c91f5b6c-9819-409b-b716-bade6b5db761">Wall of gallbladder</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_12b98ef6-44ac-4436-b751-5fa29f626fd4"/>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9c5fc806-8b8f-4105-972f-e4d62e02da0a">
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0734014" xl:show="new">C0734014</link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="5" rowspan="1">
                        <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_ccc2" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                        </emphasis></emphasis></emphasis>
                            </para>
                    </td>
                </tr>
            </tbody>
         </table>
      </section>
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new context group to PS3.16 as follows:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
      <section label="CID ccc1" status="3" xml:id="sect_CID_ccc1">
          <title>Couinaud Liver Segments</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para>
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_ccc1.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_ccc1.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_ccc1.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu1.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para>
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para>
                            <emphasis role="bold"><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para>
                     <emphasis role="bold">1.2.840.10008.6.1.uuu1</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID ccc1" rules="all" xml:id="table_CID_ccc1">
             <caption>Couinaud Liver Segments</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                <para>Coding Scheme Designator</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para>Code Value</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para>Code Meaning</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para>SNOMED-RT ID</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para>UMLS Concept Unique ID</para>
            </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para>SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/71133005" xl:show="new">71133005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para>Couinaud hepatic segment I</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/71133005" xl:show="new">T-62023</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0227489" xl:show="new">C0227489</link>
                            </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para>SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277956007" xl:show="new">277956007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para>Couinaud hepatic segment II</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277956007" xl:show="new">T-D054F</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0457139" xl:show="new">C0457139</link>
                            </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para>SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277957003" xl:show="new">277957003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para>Couinaud hepatic segment III</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277957003" xl:show="new">T-D0567</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0457140" xl:show="new">C0457140</link>
                            </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para>SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277958008" xl:show="new">277958008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para>Couinaud hepatic segment IV</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277958008" xl:show="new">T-D056A</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0457141" xl:show="new">C0457141</link>
                            </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para>SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277959000" xl:show="new">277959000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para>Couinaud hepatic segment V</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277959000" xl:show="new">T-D056B</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0457142" xl:show="new">C0457142</link>
                            </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para>SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277960005" xl:show="new">277960005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para>Couinaud hepatic segment VI</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277960005" xl:show="new">T-D056C</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0457143" xl:show="new">C0457143</link>
                            </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para>SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277961009" xl:show="new">277961009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para>Couinaud hepatic segment VII</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277961009" xl:show="new">T-D056D</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0457144" xl:show="new">C0457144</link>
                            </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para>SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277962002" xl:show="new">277962002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para>Couinaud hepatic segment VIII</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="http://snomed.info/id/277962002" xl:show="new">T-D056E</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0457145" xl:show="new">C0457145</link>
                            </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
        
        <section label="CID ccc2" status="3" xml:id="sect_CID_ccc2">
            <title>Liver Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_ccc2.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_ccc2.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_ccc2.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu2.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold"><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uuu2</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID ccc2" rules="all" xml:id="table_CID_ccc2">
                <caption>Liver Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para>
                                <emphasis role="italic">Include <xref linkend="sect_CID_ccc1" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        
        
        <section label="G" status="1" xml:id="chapter_G">
      <title>English Code Meanings of Selected Codes (Normative)</title>
      <table frame="box" label="G-1" rules="all" xml:id="table_G-1">
         <caption>English Code Meanings of Selected Codes</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                <para>Coding Scheme Designator</para>
            </th>
               <th align="center" colspan="1" rowspan="1">
                <para>Code Value</para>
            </th>
               <th align="center" colspan="1" rowspan="1">
                <para>Code Meaning</para>
            </th>
            </tr>
         </thead>
         <tbody>
             <tr valign="top">
                 <td align="center" colspan="1" rowspan="2">
                     <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                 </td>
                 <td align="center" colspan="1" rowspan="2">
                     <para>
                         <link xl:href="http://snomed.info/id/71133005" xl:show="new"><emphasis role="bold"><emphasis role="underline">71133005</emphasis></emphasis></link>
                            </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Couinaud hepatic segment I</emphasis></emphasis></para>
                 </td>
             </tr>
             <tr valign="top">
                 <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Caudate lobe of liver</emphasis></emphasis></para>
                 </td>
             </tr>
         </tbody>
      </table>
   </section>
                 
         


        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.6 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <table frame="box" label="A-3" rules="all" xml:id="table_A-3">
            <caption>Context Group UID Values</caption>
            <thead>
                <tr valign="top">
                    <th align="center" colspan="1" rowspan="1">
                        <para>
                            <emphasis role="bold">Context UID</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para>
                            <emphasis role="bold">Context Identifier</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para>
                            <emphasis role="bold">Context Group Name</emphasis>
                        </para>
                    </th>
                </tr>
            </thead>
            <tbody>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para>...</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para>...</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para>...</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.6.​1.​uuu1</emphasis></emphasis></para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="underline"><emphasis role="bold">
                            <xref linkend="sect_CID_ccc1" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_ccc1" xrefstyle="select: labelnumber"/>--></emphasis></emphasis>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para>
                            <emphasis role="bold"><emphasis role="underline"><xref linkend="sect_CID_ccc1" xrefstyle="select: title"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_ccc1" xrefstyle="select: title"/>--></emphasis></emphasis>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.6.​1.​uuu2</emphasis></emphasis></para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="underline"><emphasis role="bold">
                            <xref linkend="sect_CID_ccc2" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_ccc2" xrefstyle="select: labelnumber"/>--></emphasis></emphasis>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para>
                            <emphasis role="bold"><emphasis role="underline"><xref linkend="sect_CID_ccc2" xrefstyle="select: title"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_ccc2" xrefstyle="select: title"/>--></emphasis></emphasis>
                        </para>
                    </td>
                </tr>
            </tbody>
        </table>
        
        
        
        
        
        
        
         

    </chapter>
</book>