<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2002</title>
    <subtitle>Add to well known brain atlas frames of reference</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/01/29</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/01/04</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2002</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add to well known brain atlas frames of reference</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.6</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para>
                    <para>Supplement 73 Spatial Registration Storage SOP Classes introduced various well-known frames of reference for the brain defined by UIDs.</para>
                    <para>Since then, more atlases have been defined and are used for brain segmentation and analysis. These are used for such things as AI/ML based segmentation challenges.</para>
                    <para>Add corresponding well-known frame of reference UIDs.</para>
                    <para>Also, update ICBM atlas links, since LONI has moved from UCLA to USC.</para>
                    <para><emphasis role="italic">[Open Issue: Do we need to add the MNI152 atlas (aka. ICBM152 - so what should we call it?) and what is the best reference and what are the linear and non-linear and asymmetric and symmetric variants, and what about the already "linearly transformed to Talairach space" comment? See <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://nist.mni.mcgill.ca/?page_id=714">http://nist.mni.mcgill.ca/?page_id=714</link>. What about the MNI-ICBM2009c version vs. 2009a etc.?]</emphasis></para>
                    <para><emphasis role="italic">[Open Issue: Do we need to add MNI305? See <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://nist.mni.mcgill.ca/?p=957">http://nist.mni.mcgill.ca/?p=957</link>. What about the differenttly sampled variants discussed in <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://onlinelibrary.wiley.com/doi/full/10.1002/hbm.20345">http://onlinelibrary.wiley.com/doi/full/10.1002/hbm.20345</link> ? Do we need a generic/nominal "MNI coordinates" (a la Talairach atlas 1.2.840.10008.1.4.​1.​1) FoR when no specific template is referenced?]]</emphasis></para>
                    <para><emphasis role="italic">[Open Issue: Do we need to add the MNI Pediatric atlases?]</emphasis></para>
                    <para><emphasis role="italic">[Open Issue: Do we need to distinguish existing ICBM452 from ICBM452/warp5, and ICBM452/air12 variants, and if so should we retire the existing UID as ambiguous? See <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://bmap.ucla.edu/portfolio/atlases/ICBM_452_T1_Atlas/">http://bmap.ucla.edu/portfolio/atlases/ICBM_452_T1_Atlas/</link>.]</emphasis></para>
                    <para><emphasis role="italic">[Open Issue: Do we need to add more ICBM templates, e.g. ICBM DTI-81?]</emphasis></para>
                    <para><emphasis role="italic">[Open Issue: Do we need to add any animal atlases?]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.6 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>

        <section label="A" status="1" xml:id="chapter_A">
            <title>Registry of DICOM Unique Identifiers (UIDs) (Normative)</title>
            <table frame="box" label="A-1" rules="all" xml:id="table_A-1">
                <caption>UID Values</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89103697-fd54-4c3f-abbe-5655ae35308b">
                                <emphasis role="bold">UID Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb5b6b8a-9aec-44f2-8cdc-800a7cd327b7">
                                <emphasis role="bold">UID Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08eb5599-7f50-4d17-bd10-6617063c6e31">
                                <emphasis role="bold">UID Type</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42e221e9-efb2-49d7-8712-69266c9bc2d4">
                                <emphasis role="bold">Part</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_adaae4b9-b941-4326-a652-1423bcf7d61d">1.2.840.10008.1.4.​1.​1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2fe1f30f-d275-4bba-898c-e50e5740a6da">Talairach Brain Atlas Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e16863ee-ca15-40b7-88fe-ef4385ddc2c2">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c55ad4bd-88f0-49e5-a160-1845359f2b8e"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7815b2bf-f1c2-4ba5-8d28-eb0c485882b7">1.2.840.10008.1.4.​1.​2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1062d9cb-5cad-4249-b743-4c610ad2ad40">SPM2 T1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2f3fe6c1-b2c5-4d0d-830a-56a7de7fd0fa">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d6996627-55d0-41bc-87f6-6354ffaabe02"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aceea512-e066-4d22-babb-d505de7e5832">1.2.840.10008.1.4.​1.​3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cdfda993-9f30-4945-bcfb-c97d600cb107">SPM2 T2 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1f8f36cf-15b7-4536-b8a5-a6b6cc96ec27">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b9c22aa1-c82d-4dcf-ab52-b107e8edf6da"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_637be4ec-825a-4806-ba0b-434261e0968e">1.2.840.10008.1.4.​1.​4</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0429b126-705d-43a5-9ddd-faaa6f8495ce">SPM2 PD Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a51ba643-c7a9-48ae-80aa-0e50d95f4874">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6fe073b9-31e0-4052-9023-e4b4e53cf8d0"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6688fc98-8f0b-407c-8204-6cf198eabfe1">1.2.840.10008.1.4.​1.​5</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5403e197-f7e6-4642-9fc7-71da96cf1eeb">SPM2 EPI Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_540dccf2-308c-4c0e-acc3-72d72268c2b6">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ea2e2e1e-0e2d-4142-8e5e-5c6560596fd7"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_505c1678-aef4-4f1d-8a56-9de5d82dde88">1.2.840.10008.1.4.​1.​6</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e5108098-6c20-4d21-be89-013cfe51492e">SPM2 FIL T1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2a3c141a-d29f-4952-89f9-bce1989570e1">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bcaf79b0-9725-4d1c-886d-60c922fb1d14"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c0dcb087-dfbf-42b2-bce7-041ee0b91464">1.2.840.10008.1.4.​1.​7</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d2b40923-787f-4007-9ecc-68005e93ed23">SPM2 PET Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f398a237-42ba-4b5f-b8a5-5424fba9f8e6">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc9e1896-ab85-4cf7-a85b-577328bb37a0"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0fc8c008-79ae-4153-9ac4-80eecf7a40f5">1.2.840.10008.1.4.​1.​8</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9b8a32e7-1a08-43d6-ba46-ceab66f04283">SPM2 TRANSM Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9d875081-f8a5-44c0-9362-1df94b9c4e1a">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ed850c47-978d-4b97-b6d5-b4939a2b6676"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_03ee6c06-ae11-41ea-9c3f-778b78688658">1.2.840.10008.1.4.​1.​9</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a6c7d921-4a78-40f6-a7c4-a665f3b9e5af">SPM2 SPECT Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1280eec9-f895-41af-adb2-943b49c7dde3">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_36613f6e-8f6c-41c3-8cd3-39d2f31201bc"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_22097949-bfe2-4348-844c-1638a22ea81b">1.2.840.10008.1.4.​1.​10</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_84d666fa-a0f6-456b-b8db-ecaf55922e52">SPM2 GRAY Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8d62de02-ea80-4918-96e5-42ba49a0e55e">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0af9d89c-c09a-4b5e-8bf8-1bf9c6bf1bae"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5791b048-dff9-4566-8be6-01414c0ba301">1.2.840.10008.1.4.​1.​11</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a35a20f2-07e7-4998-b970-093db7198db2">SPM2 WHITE Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_edbaec07-1811-467b-ade8-1936b06e0bce">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_907ff504-334e-4a78-9daf-c93de0fd6227"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a74e658f-3b67-45b6-b5f7-22da7294939e">1.2.840.10008.1.4.​1.​12</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a388a9b6-ab14-476a-9743-f22aa72010b7">SPM2 CSF Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a9f9e198-62cf-422b-b6ce-ccd9f862778c">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93e97bae-f3dd-4a55-a96a-0c907305399f"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9c199158-6b38-4fe6-9a36-321227f64d65">1.2.840.10008.1.4.​1.​13</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3143db6a-cc69-4481-b90e-c6f94bb16066">SPM2 BRAINMASK Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5013bdc0-af85-4194-a708-f95eb7250b96">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89cb040c-546f-414e-9d5d-11b323b1ec04"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a6ba340c-982e-41e5-abf4-0e4f5bb335a6">1.2.840.10008.1.4.​1.​14</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f671c7af-4917-41ac-a94e-2d5e8a972451">SPM2 AVG305T1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_695dd7e0-2e55-4937-b3f6-67b306d60e89">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ca8b12cc-f4ba-447d-8074-db04e2f85508"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_54e7e59d-93fb-4cf3-871f-dcd5ff548cb3">1.2.840.10008.1.4.​1.​15</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e894fec2-f410-43e1-b429-a6e46d4a357e">SPM2 AVG152T1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_42354472-dc2d-456b-8194-9c4cfd0bd40f">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef8edeac-efe4-4fb5-8fa5-fb4b5896541d"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5449af3a-c41a-4602-88fe-3c11cece3faf">1.2.840.10008.1.4.​1.​16</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5c4f9290-6ce2-465e-a4db-f7963785b466">SPM2 AVG152T2 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c9859bc8-4807-4c28-bca5-2168d81ac71c">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c440ae61-8f02-4831-b652-7c45543e839c"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0c8ab9bd-d956-4c86-979a-9a48145d2417">1.2.840.10008.1.4.​1.​17</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b8fa57b9-7acb-4224-be05-5e97d8c15617">SPM2 AVG152PD Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_53637325-d01e-44e9-98c3-23b54dfb0c67">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa8a875d-93d7-4b97-a55f-c428247e2498"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_64c238f7-061d-48ed-9a4e-5580ddf01a25">1.2.840.10008.1.4.​1.​18</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d92371e2-eee1-4b76-940d-c0ed3837ff25">SPM2 SINGLESUBJT1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_88df3e89-8ff9-4652-89d9-61e838f43618">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_663db888-453f-4bd8-90c8-d1b588382bcc"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_286dfe49-686e-47a6-bddc-4f1bf049df03">1.2.840.10008.1.4.​2.​1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a875f7f3-0981-4d25-98bd-15cb4196ee4a">ICBM 452 T1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_af4a1288-f94a-4a52-b66a-a5c8b3726b5c">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_be1784d4-e34a-49bf-966d-40747f4d9dc5"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_487d84d6-ae07-4907-a65a-6c5b25b0b5a1">1.2.840.10008.1.4.​2.​2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_932797b4-d7e9-4713-b8a4-62ccd88784a0">ICBM Single Subject MRI Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_783077c7-7134-4444-986a-89974928a975">Well-known frame of reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42a44966-7c08-4591-8573-2956eda235e5"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.4.​2.​X1</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SRI24 Frame of Reference</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Well-known frame of reference</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.4.​2.​Y1</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Colin27 Frame of Reference</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Well-known frame of reference</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.4.​2.​Z1</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">LPBA40/AIR Frame of Reference</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Well-known frame of reference</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.4.​2.​Z2</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">LPBA40/FLIRT Frame of Reference</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Well-known frame of reference</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.4.​2.​Z3</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">LPBA40/SPM5 Frame of Reference</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Well-known frame of reference</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
            
            <table frame="box" label="A-2" rules="all" xml:id="table_A-2">
                <caption>Well-known Frames of Reference</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b2f66e8-4232-407f-88b9-06ac0bfc17ec">UID Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9bebba6d-8bc7-4a06-b87e-68dd2ab7be42">UID Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ca9a076-9357-4809-b6d0-9b785557e11f">Normative Reference</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_398f82f3-0659-4c0a-b4fa-080261fa8808">1.2.840.10008.1.4.​1.​1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5c73178a-e314-4f5f-8812-331d2c13a045">Talairach Brain Atlas Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cdb89db0-3271-460d-bf73-b1a8504bc74e">Talairach J. and Tournoux P. Co-Planar stereotactic atlas of the human brain. Stutgart: Georg Thieme Verlag, 1988.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b961d129-b9c6-4fe0-9d99-b09775bf2540">1.2.840.10008.1.4.​1.​2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f407fce3-a31f-4bf6-adb1-65f4ef42a401">SPM2 T1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9e14ab04-d31c-4ff0-8e9e-d73674aa7d6f">
                                <link xl:href="http://github.com/spm/spm2/blob/master/templates/T1.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/templates/T1.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2df36919-3189-458d-a146-a97d419d5e09">1.2.840.10008.1.4.​1.​3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d9f708d7-24c1-4107-a9a5-81c3b1cdb843">SPM2 T2 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_90fdfc3a-20ef-47f9-a29b-c46df276c573">
                                <link xl:href="http://github.com/spm/spm2/blob/master/templates/T2.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/templates/T2.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_85a20fa2-f232-4f34-87c2-50a5a20c0123">1.2.840.10008.1.4.​1.​4</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_98165335-d6e4-4e35-a7c3-8aa44c8e020e">SPM2 PD Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_66c04baf-6f6b-4959-958e-e2ea4a4bee29">
                                <link xl:href="http://github.com/spm/spm2/blob/master/templates/PD.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/templates/PD.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6b6b41a6-b650-4903-86d2-f2fa8a848ef7">1.2.840.10008.1.4.​1.​5</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e7b7331a-8722-4434-9a20-246ef7792645">SPM2 EPI Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e25debf5-020a-4c2f-b43b-53474bda30bd">
                                <link xl:href="http://github.com/spm/spm2/blob/master/templates/EPI.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/templates/EPI.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_559684c2-74d6-4099-bf74-16ac05bccbbe">1.2.840.10008.1.4.​1.​6</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a19025dc-7f31-47f0-b23a-12a498d248f7">SPM2 FIL T1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_addf0f2f-19eb-47d0-9784-bef62f97966c">
                                <link xl:href="http://github.com/spm/spm2/blob/master/templates/filT1.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/templates/filT1.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4f550a7b-1750-4e5a-a89c-8e0ffd7c2afe">1.2.840.10008.1.4.​1.​7</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e7bf0a78-880a-420c-a35d-64f1f691b814">SPM2 PET Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_05eab5fa-f8ab-4fce-b5ab-64bcf3792c84">
                                <link xl:href="http://github.com/spm/spm2/blob/master/templates/PET.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/templates/PET.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bd3a2733-db54-42b3-89bb-67bb985b168b">1.2.840.10008.1.4.​1.​8</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4d99db4e-7e92-4cc7-89ea-3d18ffa4944b">SPM2 TRANSM Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5206bcd9-d696-415c-8a50-e89c4dc570e5">
                                <link xl:href="http://github.com/spm/spm2/blob/master/templates/Transm.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/templates/Transm.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b9148817-4095-438d-9195-fefd74b2844c">1.2.840.10008.1.4.​1.​9</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_65990304-95f5-4ce5-9e63-9fe0ef01a3ea">SPM2 SPECT Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7448f39d-496a-461f-8f9a-ca91957bbb46">
                                <link xl:href="http://github.com/spm/spm2/blob/master/templates/SPECT.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/templates/SPECT.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_532ddb47-9916-4f33-9722-8e5f6e1b0a9c">1.2.840.10008.1.4.​1.​10</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c97f1a0f-a013-4244-8493-865fa3536983">SPM2 GRAY Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_743afa4c-068d-4340-a1a7-084327c0b9a4">
                                <link xl:href="http://github.com/spm/spm2/blob/master/apriori/gray.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/apriori/gray.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0fbecded-f358-4ef5-bd19-5ff885781eb9">1.2.840.10008.1.4.​1.​11</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b1c85e48-3490-4452-ba89-b37746bdc9a9">SPM2 WHITE Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f2e9f48a-2a92-40f0-8301-5092d274846d">
                                <link xl:href="http://github.com/spm/spm2/blob/master/apriori/white.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/apriori/white.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_72b35a97-8002-4f26-8a30-43f68c29779d">1.2.840.10008.1.4.​1.​12</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4dc13ba0-e801-41f3-bc39-2f1fe0eab0fa">SPM2 CSF Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fbbea0ca-09f5-4fa5-a1f3-ef3a37e1f4a0">
                                <link xl:href="http://github.com/spm/spm2/blob/master/apriori/csf.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/apriori/csf.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9941eb03-d37b-4592-bd5b-f3f0222b347a">1.2.840.10008.1.4.​1.​13</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8c40e107-6d45-4e57-a97a-e21efa6ce77b">SPM2 BRAINMASK Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a5ffd55b-e238-4c4f-90f6-07700c11c4a7">
                                <link xl:href="http://github.com/spm/spm2/blob/master/apriori/brainmask.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/apriori/brainmask.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_653e192a-3a2f-494f-ab12-4fb50b9b07c3">1.2.840.10008.1.4.​1.​14</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_752ad7b2-40f9-4936-aff1-f6d2e6900dad">SPM2 AVG305T1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_df1a54e9-db21-4778-b159-8927ff24c9e5">
                                <link xl:href="http://github.com/spm/spm2/blob/master/canonical/avg305T1.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/canonical/avg305T1.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8c477109-0f1b-4191-9f1b-6fdf57ca8a25">1.2.840.10008.1.4.​1.​15</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a65f8743-ca2a-4e66-86a1-d6a727ccba39">SPM2 AVG152T1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_26b5675c-c452-4b9b-9e74-a4a9fa3faf66">
                                <link xl:href="http://github.com/spm/spm2/blob/master/canonical/avg152T1.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152T1.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_49595c8c-ba19-498d-8ac1-017a047402c7">1.2.840.10008.1.4.​1.​16</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f075e94d-919a-4ad9-b3c6-947bf2091e95">SPM2 AVG152T2 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f6ad5a2b-2538-40b3-ae55-e296357c3984">
                                <link xl:href="http://github.com/spm/spm2/blob/master/canonical/avg152T2.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152T2.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2ecc2d91-f970-4871-99a4-a69977d066db">1.2.840.10008.1.4.​1.​17</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_00c20b5c-ab49-403c-b626-ddcb4966e843">SPM2 AVG152PD Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7220b027-e0a8-40fe-b743-a950b594b90d">
                                <link xl:href="http://github.com/spm/spm2/blob/master/canonical/avg152PD.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152PD.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_adaf7fe5-7fee-41de-897c-f59c0caa5575">1.2.840.10008.1.4.​1.​18</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ba57cb14-7b11-444f-a1ae-75bd0b930df7">SPM2 SINGLESUBJT1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_14500d05-ab32-4cfd-8be5-ad6fef629bf3">
                                <link xl:href="http://github.com/spm/spm2/blob/master/canonical/single_subj_T1.mnc?raw=true">http://​github.com/​spm/​spm2/​blob/​master/canonical/single_subj_T1.mnc</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_295f9ca4-3681-4ad1-86b7-c1692c44bff4">1.2.840.10008.1.4.​2.​1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_79bf4820-28d6-49e8-9426-f2a9402dbfd8">ICBM 452 T1 Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_867ce26c-42a9-4003-98e4-e64c4656b2a6">ICBM452 T1 Atlas</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_caeaff79-9ec1-42e6-8491-d598ccf41526">1.2.840.10008.1.4.​2.​2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_77be23f6-adba-4b3f-8e94-acc80d494153">ICBM Single Subject MRI Frame of Reference</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_609d73d9-07e7-4fd4-9044-85543dc778ab">ICBM Single Subject MRI Anatomical Template</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.4.​2.​X1</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SRI24 Frame of Reference</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><link xl:href="http://www.nitrc.org/projects/sri24/"><emphasis role="bold"><emphasis role="underline">http://www.nitrc.org/projects/sri24/</emphasis></emphasis></link></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.4.​2.​Y1</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Colin27 Frame of Reference</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><link xl:href="http://www.bic.mni.mcgill.ca/ServicesAtlases/Colin27"><emphasis role="bold"><emphasis role="underline">http://www.bic.mni.mcgill.ca/ServicesAtlases/Colin27</emphasis></emphasis></link></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.4.​2.​Z1</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">LPBA40/AIR Frame of Reference</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><link xl:href="http://resource.loni.usc.edu/atlasfiles/LPBA40_AIR_Atlas_NIFTI_format.zip"><emphasis role="bold"><emphasis role="underline">http://resource.loni.usc.edu/atlasfiles/LPBA40_AIR_Atlas_NIFTI_format.zip</emphasis></emphasis></link></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.4.​2.​Z2</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">LPBA40/FLIRT Frame of Reference</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><link xl:href="http://resource.loni.usc.edu/atlasfiles/LPBA40_FLIRT_Atlas_NIFTI_format.zip"><emphasis role="bold"><emphasis role="underline">http://resource.loni.usc.edu/atlasfiles/LPBA40_FLIRT_Atlas_NIFTI_format.zip</emphasis></emphasis></link></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.4.​2.​Z3</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">LPBA40/SPM5 Frame of Reference</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><link xl:href="http://resource.loni.usc.edu/atlasfiles/LPBA40_SPM5_atlas_NIFTI_format.zip"><emphasis role="bold"><emphasis role="underline">http://resource.loni.usc.edu/atlasfiles/LPBA40_SPM5_atlas_NIFTI_format.zip</emphasis></emphasis></link></para>
                        </td>
                    </tr>
                </tbody>
            </table>


            <para xml:id="para_fccd9fc4-425c-4295-aa40-ab552dc93eb2">SPM2 (Statistical Parametric Mapping) templates are available at <link xl:href="http://github.com/spm/spm2/"/>, and they are described at <link xl:href="http://github.com/spm/spm2/blob/master/spm_templates.man"/>.</para>
            <para xml:id="para_9544e09f-7fb9-4a5d-98d1-35436754ba0f">ICBM templates are available at
                <link xl:href="http://www.loni.ucla.edu/ICBM/ICBM_ICBMAtlases.html"><emphasis role="bold"><emphasis role="strikethrough">http://www.loni.ucla.edu/ICBM/ICBM_ICBMAtlases.html</emphasis></emphasis></link>
                <link xl:href="http://resource.loni.usc.edu/resources/atlases-downloads/"><emphasis role="bold"><emphasis role="underline">http://resource.loni.usc.edu/resources/atlases-downloads/</emphasis></emphasis></link>
                and
                <link xl:href="http://bmap.ucla.edu/portfolio/atlases"><emphasis role="bold"><emphasis role="underline">http://bmap.ucla.edu/portfolio/atlases</emphasis></emphasis></link>
                .</para>


        </section>
    </chapter>
</book>