<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2000</title>
    <subtitle>Angle measurement codes and templates</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/07/04</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top">Imaging Data Commons (IDC)</td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/12/27</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2000</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Angle measurement codes and templates</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3, PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para>
                    <para>There are no standard template structures or codes defined for recording angle measurements on images, or for describing vectors, or approximate spatial locations. Add them.</para>
                    <para>The significance of the order of the points when more than one is present is not specified. Clarify.</para>
                    <para>A line segment code for linear distances is also added.</para>
                    <para>See also CP 2036 "Add optional Source Concept Name for otherwise anonymous image, waveform and coordinate Content Items in SR".</para>
                    <para><emphasis role="italic">[Ed.Note: SNOMED CRS Request ID 748352 for code 285285000, Request ID #751234 for 260753009.]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.3 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="C.18.6" status="3" xml:id="sect_C.18.6">
            <title>Spatial Coordinates Macro</title>
            <para xml:id="para_57685ded-86b7-42d1-84f1-8db0e61ac3d8">
                <xref linkend="table_C.18.6-1" xrefstyle="select: label"/> specifies the Attributes that convey Spatial Coordinates in an SCOORD Content Item. An SCOORD Content Item shall always be the Source Content Item of one or more SELECTED FROM Relationships with IMAGE Target Content Items. Each IMAGE Target Content Item shall contain a reference to one single-frame or multi-frame Image.</para>
            <note>
                <para xml:id="para_75722d9c-dfc1-4f59-b258-93f218c72a1c">The same set of spatial coordinates may be selected from more than one single-frame image, or more than one frame of a multi-frame image when the purpose of reference is applicable to multiple images. For example, the spatial coordinates may specify the outline of a sampling region at the same spatial location on multiple images acquired over time.</para>
            </note>
            <table frame="box" label="C.18.6-1" rules="all" xml:id="table_C.18.6-1">
                <caption>Spatial Coordinates Macro Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fb16c104-bbd3-4c65-8ecc-e611706a39ec">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_040ef21d-1f18-4d23-84bc-94daa1e46849">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d8dfe25-9542-4b5d-b7c2-337eb338fd72">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ede1b99-347c-488a-b154-089ade0e3979">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bd0d82b4-d3b5-4fbd-b997-61584465b5f9">Graphic Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef5ec2ae-a9d5-4d0d-b878-d6dc631c770a">(0070,0022)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4191e523-3cda-4f79-8328-def0c68fb272">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8911574e-fccd-403b-b988-7bd3f926e555">An ordered set of (column,row) pairs that denote positions in an image specified with sub-pixel resolution such that the origin at the TLHC of the TLHC pixel is 0.0\0.0, the BRHC of the TLHC pixel is 1.0\1.0, and the BRHC of the BRHC pixel is Columns\Rows. The values must be within the range 0\0 to Columns\Rows. The maximum values are those contained in the referenced image in Attributes Columns (0028,0011) and Rows (0028,0010), or in the case of spatial coordinates with Pixel Origin Interpretation (0048,0301) value VOLUME, in Attributes Total Pixel Matrix Columns (0048,0006) and Total Pixel Matrix Rows (0048,0007).</para>
                            <para xml:id="para_69a3113b-0b9d-48d8-8e61-5a2cdf4c6d1b">See <xref linkend="sect_C.18.6.1.1" xrefstyle="select: label"/> for further explanation.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cb797e6c-c63e-49de-958c-9366d61817dd">Graphic Type</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c87f044-5f08-4d95-937d-249834c5feb2">(0070,0023)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b7a457b5-da53-4b7b-bf8f-b6673c41f2cf">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_550c1293-f796-4c98-a5c6-b077914911da">See <xref linkend="sect_C.18.6.1.2" xrefstyle="select: label"/> for Enumerated Values.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bd6eccd4-50ce-42b0-be3d-7003d1c87182">Pixel Origin Interpretation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3587a23-1baf-46b1-97ae-ff28fd61b0a8">(0048,0301)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d3d0efef-cf2c-46ba-b6ca-a4d1101787b2">1C</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3f0d17cb-eeee-420a-9fb6-7d4b96371adc">For a referenced multi-frame image, specifies whether the Graphic Data (0070,0022) values are to be interpreted relative to the individual frame pixel origins, or relative to the Total Pixel Matrix origin (see <xref linkend="sect_C.8.12.4.1.4" xrefstyle="select: label"/>).</para>
                            <para xml:id="para_bdc64395-2da3-447e-9cf8-524889c11b57">Required if the value of Referenced SOP Class UID (0008,1150) of the referenced image is 1.2.840.10008.5.1.4.1.1.77.1.6 (VL Whole Slide Microscopy Image). May be present otherwise.</para>
                            <variablelist spacing="compact">
                                <title>Enumerated Values:</title>
                                <varlistentry>
                                    <term>FRAME</term>
                                    <listitem>
                                        <para xml:id="para_ca2fe150-f33c-4fa9-a094-9f3384a02b23">relative to individual frame</para>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>VOLUME</term>
                                    <listitem>
                                        <para xml:id="para_ed1ca24a-0865-4ad8-95cc-0fd1fcef5a29">relative to Total Image Matrix</para>
                                    </listitem>
                                </varlistentry>
                            </variablelist>
                            <para xml:id="para_de6f0d64-c1fa-42b9-9954-d9353ce58cf6">If not present, Graphic Data values are defined relative to the frame pixel origin.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_eb5ed33c-3fba-4dd5-b0ef-55f7b2821b07">Fiducial UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fff70cc9-36f5-4ce6-aa9f-df33cc4fd879">(0070,031A)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0b596f13-0bd6-4d5d-99cc-a94808da1b30">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9ed48d44-1668-4abb-ba99-4ead4d4ef166">The globally unique identifier for this fiducial Item.</para>
                            <note>
                                <para xml:id="para_4c8b125c-6aa3-4ed3-b3aa-f877beccd8e2">The fiducial UID can be used to associate this set of graphics with other Content Items.</para>
                            </note>
                        </td>
                    </tr>
                </tbody>
            </table>
            <section label="C.18.6.1" status="4" xml:id="sect_C.18.6.1">
                <title>Spatial Coordinates Macro Attribute Descriptions</title>
                <section label="C.18.6.1.1" status="5" xml:id="sect_C.18.6.1.1">
                    <title>Graphic Data</title>
                    <para xml:id="para_82c23f4e-72db-4a43-b60f-a2554596f5db">Graphic Data may be used to associate an anatomic or spatial Concept with a defined subset of one or more images. Graphic Data may be explicitly defined as a single point (i.e., to denote the epicenter of an anatomic site or lesion) or more than one point (i.e., representing a set of points or an open or closed polygon).</para>
                    <note>
                        <para xml:id="para_b4f36a81-4d05-43d2-a35f-6ebc51d0a801">Spatial coordinates may be used to associate observational data with a set of Image features. Spatial coordinates also may be used to convey coordinates that are input data for a measurement.</para>
                    </note>
                </section>
                <section label="C.18.6.1.2" status="5" xml:id="sect_C.18.6.1.2">
                    <title>Graphic Type</title>
                    <para xml:id="para_e1569678-a43c-4c51-87d0-39c54b4fdc96">When annotation applies to an image, this Attribute defines the type of geometry of the annotated region of interest.</para>
                    <variablelist spacing="compact">
                        <title>Enumerated Values:</title>
                        <varlistentry>
                            <term>POINT</term>
                            <listitem>
                                <para xml:id="para_afa0a51e-1aac-4782-b89f-aaa3a98f4cf5">a single pixel denoted by a single (column,row) pair</para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>MULTIPOINT</term>
                            <listitem>
                                <para xml:id="para_58a9bf90-5471-45ee-a2e3-bb0d5cfdbafc">multiple pixels each denoted by an (column,row) pair</para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>POLYLINE</term>
                            <listitem>
                                <para xml:id="para_788d63e8-81db-47d6-b916-950ee768a901">a series of connected line segments with ordered vertices denoted by (column,row) pairs; if the first and last vertices are the same it is a closed polygon</para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>CIRCLE</term>
                            <listitem>
                                <para xml:id="para_b1c96c35-bba3-494a-b76a-67b16a1a68e3">a circle defined by two (column,row) pairs. The first point is the central pixel. The second point is a pixel on the perimeter of the circle.</para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>ELLIPSE</term>
                            <listitem>
                                <para xml:id="para_57094a0c-0837-4e8f-84d2-9cd6760a55e0">an ellipse defined by four pixel (column,row) pairs, the first two points specifying the endpoints of the major axis and the second two points specifying the endpoints of the minor axis of an ellipse</para>
                            </listitem>
                        </varlistentry>
                    </variablelist>
                    <note>
                        <orderedlist>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">The order of encoding of successive points for any particular Graphic Type is significant, but its meaning is not specified. The meaning of the order may be defined by a particular Template that uses them. For example, a closed POLYLINE may be encoded with a clockwise (right) or counter-clockwise (left) winding order (when viewed from a specified direction). A two-point POLYLINE used to encode a vector with a direction might be expected to originate at the first encoded point and be directed towards the second encoded point, but that is not specified.</emphasis></emphasis></para>
                            </listitem>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">A Polygon encoded as a POLYLINE is not restricted to being a simple polygon, unless so specified by the Template that uses it.</emphasis></emphasis></para>
                            </listitem>
                        </orderedlist>
                    </note>
                </section>
            </section>
        </section>
        
        <section label="C.18.9" status="3" xml:id="sect_C.18.9">
            <title>3D Spatial Coordinates Macro</title>
            <para xml:id="para_fc4faee0-6fce-4049-9ed8-5330c91a795f">
                <xref linkend="table_C.18.9-1" xrefstyle="select: label"/> specifies the Attributes that convey 3D Spatial Coordinates in an SCOORD3D Content Item.</para>
            <table frame="box" label="C.18.9-1" rules="all" xml:id="table_C.18.9-1">
                <caption>3D Spatial Coordinates Macro Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6614d56-6814-45d3-86eb-f51994976da3">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5f89ce77-8bca-40df-abaa-06ad5819ba66">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3c87b83-3760-4c19-9534-9522721101c4">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ace84746-e60d-42a6-afd3-0de20e53271d">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_14610131-0a52-4367-8ebe-36688ff8305d">Referenced Frame of Reference UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b7039e8-120c-4f4e-bc2a-fc5d38e770ef">(3006,0024)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c313fb7-8b16-4198-aa6c-fe255a8991d6">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7c7851c2-ed0a-42ae-8ed9-6c0e609da550">Uniquely identifies the Frame of Reference within which the coordinates are defined.</para>
                            <note>
                                <orderedlist>
                                    <listitem>
                                        <para xml:id="para_5de7a5aa-e19a-4de1-a387-ccdc605c83cc">There is no requirement that the Frame of Reference be the same for all SCOORD3D Content Items in the same SR SOP Instance, nor is there any requirement that the <xref linkend="sect_C.7.4.1" xrefstyle="select: title"/> be present.</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_7974ffc6-802d-42f9-866d-a4d2f03d651e">The Frame of Reference may be any type of DICOM Reference Coordinate System, whether it be patient-relative (Patient Based Coordinate System), volume-relative (including acquired and presentation state volumes), or whole slide relative (Slide Coordinate System).</para>
                                    </listitem>
                                </orderedlist>
                            </note>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_66e16444-e11b-44de-a9bb-088229fb2f59">Graphic Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ae128bf-91d0-4112-90db-854417ada6df">(0070,0022)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2f3c46e-acda-43ea-a5fe-774ce2ccd23e">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_36b3d404-9d13-4e10-baf0-b51801d5568c">An ordered set of (x,y,z) triplets (in mm and may be negative) that define a region of interest in the patient-relative Reference Coordinate System defined by Referenced Frame of Reference UID (3006,0024). See <xref linkend="glossentry_ReferenceCoordinateSystem"/>.</para>
                            <para xml:id="para_e78140bb-4ee9-402f-b2ea-59388865c887">See <xref linkend="sect_C.18.9.1.1" xrefstyle="select: label"/> for further explanation.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1c595803-cecb-470d-8340-aa80c0e6e5e6">Graphic Type</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df9a6c51-d499-404d-b092-661bc168e8ec">(0070,0023)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c515a224-1f96-4bd7-a7ba-ec2be897e979">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bd6c32af-1c49-4c96-a1c2-9e0b0d05ba2f">See <xref linkend="sect_C.18.9.1.2" xrefstyle="select: label"/> for Enumerated Values.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bb1f4f0e-c88b-4d4d-ab97-76b0bd18f932">Fiducial UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78164857-6598-4e12-beab-c69858e0d6d4">(0070,031A)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa8e1315-89d0-4773-8003-65943855a707">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0d063562-efce-4409-a877-399b37943a2b">The globally unique identifier for this fiducial Item.</para>
                            <note>
                                <para xml:id="para_998c59ec-8216-4d36-a678-e8ad63ab7276">The fiducial UID can be used to associate this set of graphics with other Content Items.</para>
                            </note>
                        </td>
                    </tr>
                </tbody>
            </table>
            <section label="C.18.9.1" status="4" xml:id="sect_C.18.9.1">
                <title>3D Spatial Coordinates Macro Attribute Descriptions</title>
                <section label="C.18.9.1.1" status="5" xml:id="sect_C.18.9.1.1">
                    <title>Graphic Data</title>
                    <para xml:id="para_2da82bd8-93a4-40ec-ac95-a382aff4358a">Graphic Data may be used to associate an anatomic or spatial Concept with a defined set of patient relative 3D locations in a defined Frame of Reference, independent of any image. Graphic Data may be defined explicitly as a single point (i.e., to denote the epicenter of an anatomic site or lesion) or more than one point (i.e., representing a set of points or an open or closed polygon).</para>
                </section>
                <section label="C.18.9.1.2" status="5" xml:id="sect_C.18.9.1.2">
                    <title>Graphic Type</title>
                    <para xml:id="para_e3d83580-0d2c-4ef3-9e10-098993aa01ad">This Attribute defines the type of geometry of the region of interest.</para>
                    <variablelist spacing="compact">
                        <title>Enumerated Values:</title>
                        <varlistentry>
                            <term>POINT</term>
                            <listitem>
                                <para xml:id="para_a65eaff1-522e-4797-aef0-08b266b40bca">a single location denoted by a single (x,y,z) triplet</para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>MULTIPOINT</term>
                            <listitem>
                                <para xml:id="para_9355618b-6718-48a4-b703-31cc42bfc881">multiple locations each denoted by an (x,y,z) triplet; the points need not be coplanar</para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>POLYLINE</term>
                            <listitem>
                                <para xml:id="para_ec60e3cf-f3f2-4c43-9586-29cd6f535727">a series of connected line segments with ordered vertices denoted by (x,y,z) triplets; the points need not be coplanar</para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>POLYGON</term>
                            <listitem>
                                <para xml:id="para_f62db998-21f3-4474-9f2c-c2f869722fd5">a series of connected line segments with ordered vertices denoted by (x,y,z) triplets, where the first and last vertices shall be the same forming a polygon; the points shall be coplanar</para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>ELLIPSE</term>
                            <listitem>
                                <para xml:id="para_a24115f8-4147-4346-b86d-295c80c4eaa1">an ellipse defined by four (x,y,z) triplets, the first two triplets specifying the endpoints of the major axis and the second two triplets specifying the endpoints of the minor axis</para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>ELLIPSOID</term>
                            <listitem>
                                <para xml:id="para_0650c75e-62bd-4edc-96d0-de64ca15ab67">a three-dimensional geometric surface whose plane sections are either ellipses or circles and contains three intersecting orthogonal axes, "a", "b", and "c"; the ellipsoid is defined by six (x,y,z) triplets, the first and second triplets specifying the endpoints of axis "a", the third and fourth triplets specifying the endpoints of axis "b", and the fifth and sixth triplets specifying the endpoints of axis "c"</para>
                            </listitem>
                        </varlistentry>
                    </variablelist>
                    <note>
                        <orderedlist numeration="arabic">
                            <listitem>
                                <para xml:id="para_b214c73a-ee8d-4f31-be6a-8d547fc39376">A circle is a special case of ELLIPSE where the major and minor axis points are equidistant from the center.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_c8edeb1e-e1a4-4ceb-8328-429ce986c7cf">Coplanar is in the mathematical sense and is not necessarily related to a specific Image Instance.</para>
                            </listitem>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">The order of encoding of successive points for any particular Graphic Type is significant, but its meaning is not specified. The meaning of the order may be defined by a particular Template that uses them. For example, a closed POLYGON may be encoded with a clockwise (right) or counter-clockwise (left) winding order (when viewed from a specified direction). A two-point POLYLINE used to encode a vector with a direction might be expected to originate at the first encoded point and be directed towards the second encoded point, but that is not specified.</emphasis></emphasis></para>
                            </listitem>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">A POLYGON is not restricted to being a simple polygon, unless so specified by the Template that uses it.</emphasis></emphasis></para>
                            </listitem>
                        </orderedlist>
                    </note>
                </section>
            </section>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.16 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
         <section label="TID 300" status="3" xml:id="sect_TID_300">
            <title>Measurement</title>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_ab8fefe1-5cfb-4d98-bd8f-473072340e65">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_ef0dbab2-a679-4f50-95d5-3f82597e6279">
                        <emphasis role="bold">Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_a17f8f3a-4c87-4b2e-8c92-218843e7986f">
                        <emphasis role="bold">No</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300">
               <caption>Measurement</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_72040574-5d06-4448-92d3-65d64029aec2"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6dc1a5bb-799d-4ce7-b116-2de6f00399b0">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ada3f541-03e1-4c32-aca3-f7f3d0de93e9">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_34201b00-0939-4acb-975d-63b09c385b07">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_104a2ec7-1391-48f6-b7dc-c5f94a8bb57a">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0699ebc9-be03-4846-a7b1-e8c504fd0ae9">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_40849f85-f55e-4dd9-bc80-7af5c0e2a872">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cd9bf78e-2ee9-47a9-8a55-5cf98072a759">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9856b597-aeef-4056-a98c-25b47f0aabcf">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8e932889-0764-40b5-9f5e-ac3845d6f933">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4b175a93-7c5c-48bc-a5e5-380db6283009"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6ec6fe93-5cb0-4758-8adc-deef5678010b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5fe8320f-931e-4eec-91a8-f8d7ae6d7f00">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_48165cbf-5ff1-4353-9c7b-c05569a0066b">$Measurement</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a6d1fd64-a1d1-4245-8dc5-88b325d3094c">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5ab6a36e-54ef-41db-a7c7-de35a9843624">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5043dfda-6fa9-4044-b601-cb8254bff80b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b0e7cc06-ed22-40d7-ae42-3e8831a76b76">UNITS = $Units</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c515a4c2-545c-43c4-8e41-ade857100b6a">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c94a32ec-4213-4104-9bab-c3f6db880f93">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_689822ca-4490-4ddc-ab4b-fa40eaaf2ee0">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7fdc1a0e-c8a0-46d7-96d9-6c3d8ee2531c">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1b0eebe5-a3b6-4489-8519-995ab0fb2387">$ModType</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_72a99565-a981-43c6-b839-2ea70017869b">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9f7c2de4-d8f4-4da7-b290-b85c8d6374a9">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f35b74d0-e5b2-43a6-aa54-fe99d4fb9621"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e9202f3c-77aa-4877-8002-f52a780921c3">$ModValue</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d1a38665-2780-47a2-8288-b2ac487c6998">3</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b94e2514-7250-42fa-9b08-6b893ad01093">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_30586168-f816-4111-8cdc-f11f95a81d0b">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f382fab9-034b-41e1-aa6f-a7185be151b9">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1b72d8b6-ed15-4a08-9b5b-289774f7cf5c">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c07f112c-405c-4d23-be39-6a581360dcae">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_838f090d-85d8-4634-8fd7-e2fa6f6039b1">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f6560d8a-8154-45bf-94d2-37153ca9099f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2db623f9-eb56-4064-970f-909c99c2a31f">$Method</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e5425fb-b11e-4ce9-8481-bf4a3747daf4">4</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d6b34bf6-827a-40ba-8b4b-be7b2de154d3">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_04f58196-f7fe-45be-b29e-ae83c4d92fdc">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5542c40a-7059-4932-b225-434e716ad737">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7b90b1fb-e270-4b78-800b-1d187de4e1d5">EV <link linkend="DCM_121401" xrefstyle="select: nopage">(121401, DCM, "Derivation")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ca8df5bb-1433-4349-8f74-72b58b00b6d9">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cda9ee73-45c3-402d-8c97-9b7488003a2b">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dabc7969-5f11-4e95-90a1-c456bcbdb6a0"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4c43c691-50c8-4531-a525-c7ee0892e657">$Derivation</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_842a90c7-9b2c-4e1b-9d86-07032d12440c">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e5831500-d717-4acd-b9f0-e1830aa51c47">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5bcc1fd5-adc6-40f2-9d60-ac63e06e3ae6">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52d994f1-7970-430c-98c6-d6f793b4fc94">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5eb269ab-ac5b-4d94-8a57-65f11a3120c3">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_620460a5-326b-427c-bbf4-b91e1aadb9f0">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a5fb68de-67b6-48ad-a052-670d176b1a63">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_721786ea-c21c-4c3a-9548-550c54e19cd9"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5ecabefa-537a-4f14-8b77-f5d7e7abc868">$TargetSite</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d351ac50-bc5b-4990-95e0-590c7c311491">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2ea5b580-7476-4ccd-bf8d-1c4aae332342">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_53959fa5-9bba-4765-80fd-5b7a9880ddc8">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e500ea97-1971-4b1e-b316-09423b1e2458">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_55011eae-faab-453d-89c5-60f2b8e7a403">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0961a671-0b3c-4ded-978a-5830e6c0880e">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_27501979-c2eb-4352-a929-85fa10dc148c">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d067a1e3-0284-4cfc-beac-2c127ea50637"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                         <para xml:id="para_8ea85369-73ab-4414-bc58-9e5098ac7d70">$TargetSiteLaterality</para>
                         <para xml:id="para_760eb9f5-5cb5-4415-930b-9df9a996ac58">Defaults to D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c84a9a9d-404b-45f3-95e6-a0788c85a1e4">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9fb178ea-cdaa-40bc-be05-5206fc09fbf1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_69f456db-3070-400c-bc29-ee9e3e11d64f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c49d44f8-3d49-40da-a2f4-70949603f29c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ae97e081-9e86-4c97-90d2-d44ff283b411"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2ce576e6-dbff-44ee-a636-8edcd0056567"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d790e090-8302-446a-a659-1c295bfc889d"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4031f3f1-b19e-47da-b68d-974b820fddb1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_588bdde1-6eb6-4381-9df6-bebc5afefb83"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_770d16b5-21b5-4887-96bd-6aeaf6afd2c8">13</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_10c8009f-cdf8-481e-a705-02fa7087fc41">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b3918619-21e2-4ed1-b694-45f56b4953aa"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_161efed5-07f7-4bc4-9c2f-baffaed7e8f1">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                         <para xml:id="para_bf78b3b7-4ed9-47bf-88a9-18efa573270c">DTID 320 "Image or Spatial Coordinates"<!--<xref linkend="sect_TID_320" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e1a45d45-0533-4a14-8fba-e85f2a151d8f">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_72e4002f-993f-410a-99d7-d699a37f8340">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eaaa3c9a-40ef-4fa0-82e2-39369442ba24"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_22d6c3ff-aaca-45d7-b0a6-d0109f903293">$Purpose = $ImagePurpose</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0f1f348a-5796-4a87-9ba3-f2889749259b">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_451e74d0-aac0-48d2-99fe-d88c8f19c95e"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_efe5adcc-e9c9-4812-badf-d6d44e61aa4b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c40f07c9-ca79-4b2f-8065-7325242d588b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e79da970-e41b-4528-b581-450ab8af39d1"> </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c274ef43-d146-4065-9802-fbe6c4f48ca2"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3e6d8f0a-39ac-4c87-972c-e242109f5fe1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8ea7f370-a961-4816-867e-e6d3d41763d2"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_594b4882-e970-47db-9edb-c64c94f3421c"/>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_c568a2c1-03b8-4849-9910-d9efaf957365">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_effc493f-84f6-437c-84af-31ff7bf9c06e">Rows 2, 3, 4, 5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_33fc3488-12f8-4222-ad96-24b55739f20d">The HAS CONCEPT MOD items allow the explicit definition of terms for post-coordination of the measurement concept name. Additional post-coordinated modifier terms may be included in a SOP Instance based on this Template, in accordance with section 6.2.4, or as defined by Templates that invoke this Template and explicitly define additional post-coordinated modifiers (e.g., TID 5203).</para>
                     </td>
                  </tr>
                  <tr>
                     <td align="left" colspan="1">
                        <para xml:id="para_fcb505ed-af0f-4b3c-a679-ff3afdfa0d41">Row 5</para>
                     </td>
                     <td align="left" colspan="1">
                        <para xml:id="para_eb15fbee-f367-4d74-9be2-986aab9259f2">Finding site may be multiple when a region of interest spans multiple anatomical locations and there is not a single pre-coordinated code describing the combination of locations. E.g., when a maligant, inflammatory or traumatic process spans actual or defined anatomical boundaries. There is no requirement that the multiple locations be contiguous.</para>
                     </td>
                  </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Row 13</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Multiple SCOORD content items may be necessary to describe the source of the measurement. E.g., the measurement of an angle between two non-intersecting line segments requires two separate POLYLINE SCOORD content items with the concept name of <link linkend="DCM_ddd001" xrefstyle="select: nopage">(ddd001, DCM, "Arm of angle")</link> conveyed in $Purpose.</emphasis></emphasis></para>
                       </td>
                   </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f8478bcd-4ae8-41d3-99e5-3029ac1c531d">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8adf7435-8928-478a-a82f-a4eabcc8d850"/>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>
        
        <section label="TID 1500" status="3" xml:id="sect_TID_1500">
            <title>Measurement Report</title>
            <para xml:id="para_451fd560-e4eb-4e0d-bbbe-a2b2bc35cfdb">This Root Template encodes a list of Measurement Groups each containing lists of measurements, together with any derived measurements.</para>
            <para xml:id="para_05032633-832f-4009-aa1a-4cd0169bbcf6">Each Measurement Group is identified by Tracking ID and UIDs.</para>
            <para xml:id="para_ae0f46e9-777b-41b2-9bcb-f73d2d26cdc4">An image library is available to describe characteristics of the images referenced by the measurements, if any.</para>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_dc288621-3a74-4a7d-96e1-b497f9db2c31">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_3d90285a-5fef-466c-a809-b84a2ea3bd77">
                        <emphasis role="bold">Non-Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_554a2a02-c45c-4450-86e5-c176d0b47f9a">
                        <emphasis role="bold">Yes</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 1500" rules="all" xml:id="table_TID_1500">
               <caption>Measurement Report</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7f96ef72-3739-4709-a6f5-d3c609e4ec05"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_eb663436-d709-454e-ac93-98682212c9f0">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6142a93b-0f6d-44a4-8494-fc3299ba7c21">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_81a6fa58-162c-4816-971a-d0a224744ee1">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_97622db7-889d-46d0-a1c0-605bfed0f4c7">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_feb517dd-7464-42f5-9f1d-496753de6be4">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_220e6ae8-5f33-4f58-b426-f41cd8fd2bf4">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9af3785d-8f23-4d07-809d-5639784468c9">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_80f6672b-b0af-4725-adc3-e4e8c7e83695">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3321887d-8899-4314-b289-3d0e04bcdf8f">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fe0e84e0-be0d-437f-8baa-f2478513e5ee"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d8ae3ff8-c9ea-42bf-96e0-2414f44efbcf"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_85dac8a4-19f9-4283-bd59-d51aa905412d"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6e81e20b-a511-403a-893f-29ce62ab8e77"> </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5b5a81ce-2cb2-47bf-9730-858f4fea4387"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0b360053-7fdd-4be5-91bf-eaea1c56d55d"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ca0229a7-7804-4c95-b314-b59248fade6c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c53c5359-96e3-44c4-8875-94dba07faea0"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e00ee47b-e07a-4063-9295-f00b8f902998">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_75af0046-0485-49d9-8863-6ce205f822c6">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aa985cec-610b-4445-b7f1-2ebbab06936b">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_51feb8fa-c5e0-46a7-afcb-b82dc0f31423">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_afa5de9d-884c-4de6-8af3-0f259624c15e">D<xref linkend="sect_TID_1501" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f0cc25ff-0ec1-44cd-a6c4-4ba948d2a1ae">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2c07259d-38bc-4ccd-94bd-f6802ad60bf1">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_87d9dd51-a193-4405-b81d-59c4610661d1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_17c5d93d-3fbc-4a4b-9dc6-71a477409861">$Measurement = B<xref linkend="sect_CID_218" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                         <para><emphasis role="bold"><emphasis role="underline">$ImagePurpose = B<xref linkend="sect_CID_ccc2" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                            </para>
                        <para xml:id="para_56c17377-8203-49db-abf1-3e609e9ce931">$Units = B<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_33b0e4c5-3954-4eb8-89c2-efc8fe79d202">$Derivation = B<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_2b135bc8-4839-49ce-9cf7-18949e1ba320">$Method = B<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                         <para xml:id="para_35455f5c-df30-44e1-831c-09a7456f8614">$QualModType = B<xref linkend="sect_CID_210" xrefstyle="select: labelnumber quotedtitle nopage"/>
                         </para>
                         <para xml:id="para_4f5fbccd-7f99-468b-af89-55ae995e7628">$QualModValue = B<xref linkend="sect_CID_211" xrefstyle="select: labelnumber quotedtitle nopage"/>
                         </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f35f1012-6565-4615-94b4-a578329d628c">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8ccf6dc7-6bfa-4c00-a480-e01762c81728"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bddc1cb2-753b-4cfb-afb9-4e7d0a9a5b88"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_20defab9-20a6-4f11-8d8d-5dc3d112bce6"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_41dd250a-8b5b-4dbf-8841-b031757426a3"> </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_22a0c72b-ee47-4b01-8193-4fccee14c0f8"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_86f3c834-9d4e-457b-9727-a65324c488fe"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_30d76f5b-1438-404c-8012-2bfb78dc0bc3"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_87acdb58-5f9a-4c02-b01a-4e3975a65b68"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a8f1ea39-3c67-465b-a6c0-e5ec9e55e62b">14</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a53b3bf9-cfde-4fbf-b60a-268f596778ec">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ba2a86fd-3a78-4582-a15a-dc5e41d48a6a">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7ccaf0d9-7de6-4a29-abe8-fad1e57f1783">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_365d761d-516b-4a79-a9f1-19553ce85870"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e2921fd2-68c6-4638-bf28-994fd99a0d2b">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c2054dbc-f637-457f-8b1c-ab6c08b8c103">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ec6954c3-d4e2-422d-92bd-d2a4be05f8f6"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e5a385a8-29ef-49cb-9bf6-181e68405efc"/>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_868f2065-cd1a-426f-a9fe-19f831d32718">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                   <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fa575819-a7dc-4043-ad84-1d6ce95c8b7b">Rows 7, 8, 9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5a0d0919-bb63-4e2f-a517-75d44bd1afe1">The baseline context group allows for generic intensity, size, texture and other feature measurements, regardless of the geometry of the ROI (e.g., linear distance can be measured on volumes, or volume can be estimated from a linear distance), and being baseline, do not constrain the invoker from using other appropriate concepts specific to the application.</para>
                        <para xml:id="para_e1a80820-6ce7-44fd-ad80-00960d5bae8b">Different measurements of the same real world lesion made using different types of measurements (different templates) can be correlated by a shared value of Tracking Unique Identifer.
                             See also <olink targetdoc="PS3.17" targetptr="sect_RRR.5" xrefstyle="select: docname label quotedtitle"/>.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_91fbabf7-ecd2-4d86-9c01-2fdf528ac2c1">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ec84ec1d-b331-4604-8b00-7dc0200beeeb">...</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3e5dd0ff-8e30-48ec-8878-f4820e8e310d">Row 9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d1f9849b-4c4f-4bad-976d-800ab017f460">Generic measurements include those specified on an image as a whole or by unconstrained graphic coordinates. These may be used for such things as whole image scores or quality measures, and for linear distance meaurements, such as for RECIST or WHO tumor treatment response criteria evaluation<emphasis role="bold"><emphasis role="underline">, or angle measurements</emphasis></emphasis>.</para>
                        <para xml:id="para_14d2d51c-ea81-4ee8-8690-833d8c7aabac">A Measurement Group is used to contain one or more individual measurements that are invocations of TID 300, consistent with TIDs 1410 and 1411, which both already have Measurement Group containers as their roots.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_82f87e16-acb0-46aa-82f0-768cc05a326c">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_de8abf94-49ad-4bc0-b8e8-2dc451035fca">...</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>

        
        <section label="CID 218" status="3" xml:id="sect_CID_218">
            <title>Quantitative Image Features</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a2bab1dc-184d-485d-b9fb-f8e27a47ecfc">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_218.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_218.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_218.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1269.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a646ab0f-a25b-438a-9782-0e8a50a97bf5">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6e7d7d34-d49c-4ab3-87e5-29cf530458b2">
                            <emphasis role="bold"><emphasis role="strikethrough">20190121</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_635c2ffc-1539-4753-9ad9-364a30b56d0f">
                            <emphasis role="bold">1.2.840.10008.6.1.1269</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 218" rules="all" xml:id="table_CID_218">
                <caption>Quantitative Image Features</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db9b8522-643e-499d-b954-556e108f0f3b">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_411434a9-beb0-4491-a58d-c8256f1d9911">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2034efa-0792-43df-83e0-971c0b52a939">Code Meaning</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_dd17c90b-fd05-4593-8a9d-8d10d312cbb6">
                                <emphasis role="italic">Include CID 7468 "Texture Measurements"<!--<xref linkend="sect_CID_7468" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_bbb76df2-d60e-42e7-b5e1-166d1b9f47e4">
                                <emphasis role="italic">Include <!--CID 7469 "Generic Intensity and Size Measurements"--><xref linkend="sect_CID_7469" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_1bb6ce95-2aee-43c2-91d9-0a902dfb923f">
                                <emphasis role="italic">Include CID 7477 "Global Shape Descriptors"<!--<xref linkend="sect_CID_7477" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_ccc1" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                        </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="CID 7469" status="3" xml:id="sect_CID_7469">
            <title>Generic Intensity and Size Measurements</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ea2a84ce-a848-449d-84af-90cbbda52580">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7469.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7469.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7469.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1003.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6a75cc1e-2f95-46f0-90c5-21190e6aadd5">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_13f55a11-9c24-4c6d-a016-2b62890b7f2e">
                            <emphasis role="bold">20141110</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f80d1bb6-18fd-4f46-8aae-803475085f16">
                            <emphasis role="bold">1.2.840.10008.6.1.1003</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7469" rules="all" xml:id="table_CID_7469">
                <caption>Generic Intensity and Size Measurements</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da4f3e26-0e58-41c4-afd2-f5e0c5437d96">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af75bce2-f7e4-4337-a1c2-49a7bdc2c504">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5bbae1bf-f764-40af-ad33-0fd180a5741d">Code Meaning</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_7d5813fe-198b-458c-83fd-61d902ef1a01">
                                <emphasis role="italic">Include CID 7180 "Abstract Multi-dimensional Image Model Component Semantics"<!--<xref linkend="sect_CID_7180" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_7ecdc418-171c-4e3c-89f7-daa2f7e3fade">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7470" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_83fcba24-f472-47b1-babe-50d2ad9d4266">
                                <emphasis role="italic">Include CID 7471 ""Area Measurements<!--<xref linkend="sect_CID_7471" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_c5867b3e-d47d-4a74-baa6-d9b6a9e33900">
                                <emphasis role="italic">Include CID 7472 "Volume Measurements"<!--<xref linkend="sect_CID_7472" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        <section label="CID 7470" status="3" xml:id="sect_CID_7470">
         <title>Linear Measurements</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_97af33c9-cee2-40a6-b1bb-f286e6e6deca">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7470.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7470.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7470.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.524.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_b7c3dce4-6f9c-4192-a0d9-3e3a05302c15">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_9cb45d1f-f56c-429c-83c7-e8491d9e7dd9">
                            <emphasis role="bold"><emphasis role="strikethrough">20190121</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_a6bd7eb7-1fc7-41b3-a6fc-19ad9ec87cbf">
                     <emphasis role="bold">1.2.840.10008.6.1.524</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7470" rules="all" xml:id="table_CID_7470">
            <caption>Linear Measurements</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_24969e98-4ae5-475e-9ff0-6b235aca8c99">Coding Scheme Designator</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_4d26164c-b971-4386-90a3-4bc7f37ab49e">Code Value</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_177bb067-8968-49d4-ba5b-e00896064f59">Code Meaning</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_9b25c0f1-af74-4c20-a0a8-cc40b34ce046">SNOMED-RT ID</para>
            </th>
                  <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_30ed8af4-c33f-4c5a-8f06-53cc84d3229d">UMLS Concept Unique ID</para>
            </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e84a5c40-73ad-4959-9b27-6a2f95250a71">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_794e7979-20bb-44ae-b536-ee9d2375365d">
                        <link xl:href="http://snomed.info/id/410668003" xl:show="new">410668003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a42b3c38-c045-4875-bfe3-c687d1ec17ea">Length</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d54d0cd4-f149-4b0e-802a-4b2ea598ca72">
                        <link xl:href="http://snomed.info/id/410668003" xl:show="new">G-D7FE</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2e397078-1ba2-46e8-afc3-785c3b0ef252">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1444754" xl:show="new">C1444754</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_35a0d118-4c85-4e38-82f1-35b76929f488">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d65d7536-321c-447f-9936-21a57156a853">
                        <link linkend="DCM_121211" xrefstyle="select: nopage">121211</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0b6c63ed-5e06-4c32-82b2-3bc6c63596d0">Path length</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cfd55bbb-efda-4bdb-8fb3-95d8b146fb05"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ffe6bdab-5c32-4ab7-8612-6199713cf0f5"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5555ff59-2a52-4d52-9b13-1294624c1a40">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e74723e3-376d-4bda-93d4-ccbbbedb688b">
                        <link linkend="DCM_121206" xrefstyle="select: nopage">121206</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_bbf59580-5679-4157-b00c-4979785ac591">Distance</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dd405118-8542-467c-9739-1dbcb7d0c815"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4cc4f88e-6b88-4aab-b9e8-214a605ea82c"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_18984073-2fa4-4cd9-8aeb-99cdcd99985b">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d0c881b7-78b5-4efb-a36b-868fa207fa4e">
                        <link xl:href="http://snomed.info/id/103355008" xl:show="new">103355008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3e5b8948-6c25-45da-9bd3-5af188a20a2f">Width</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0f84fd04-5c57-4ab3-8216-526c3f12d9a7">
                        <link xl:href="http://snomed.info/id/103355008" xl:show="new">G-A220</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_33aa8f48-9b00-4043-94a4-e75bf9b0097a">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0487742" xl:show="new">C0487742</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6d910954-a416-403d-8abd-0aff53213264">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a75473a6-8797-4c44-a0c2-197d384b6859">
                        <link xl:href="http://snomed.info/id/131197000" xl:show="new">131197000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_905164a2-ceb0-4f81-834f-94fc96482bae">Depth</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b3288ac-6e6d-4a8a-960e-7837b60b7563">
                        <link xl:href="http://snomed.info/id/131197000" xl:show="new">G-D785</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_892078bb-644a-4f61-b6d2-781303ccf8f2">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205125" xl:show="new">C0205125</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_951b7ad6-54f7-489a-a4b2-c8a5a6643d88">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_21e72804-e3d0-45fe-83ae-0e27ee54f79b">
                        <link xl:href="http://snomed.info/id/81827009" xl:show="new">81827009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_70c5ddf9-cdae-44d7-8b58-b4f6d1ff261d">Diameter</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_45b6c7e3-5c87-4e3f-8568-6f2612a1532e">
                        <link xl:href="http://snomed.info/id/81827009" xl:show="new">M-02550</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c05cca22-4531-493e-9f2c-88a627d3602c">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1301886" xl:show="new">C1301886</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_154becd3-efe3-406c-98da-70858d3ff151">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_673e6aee-8855-456b-ae64-c0f8d3184929">
                        <link xl:href="http://snomed.info/id/103339001" xl:show="new">103339001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_946a10d2-0b0b-4919-8d5a-66ac71d03a73">Long Axis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e1f67cd8-29f2-4b3c-a904-a778c4ecaa20">
                        <link xl:href="http://snomed.info/id/103339001" xl:show="new">G-A185</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_006a3534-ff27-4284-aba3-1d7026e4d27b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522487" xl:show="new">C0522487</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_de6e7a38-70c6-4554-9d62-b73d37c59617">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_48de58cc-2a27-4f1a-948a-717636a7487e">
                        <link xl:href="http://snomed.info/id/103340004" xl:show="new">103340004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_60db2604-71ba-4a3e-8566-cbc41a07ed05">Short Axis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6fad58e0-9ec7-48fc-8e9b-b8c61c451769">
                        <link xl:href="http://snomed.info/id/103340004" xl:show="new">G-A186</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fc73f69d-abc9-4446-85dd-849c5e17fc6c">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522488" xl:show="new">C0522488</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_de8c7f24-2d8c-4529-89ba-cf8f63c3f4ae">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2eb90a61-a232-41f0-af0e-c94e56245800">
                        <link xl:href="http://snomed.info/id/131187009" xl:show="new">131187009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9b37f283-3ff0-4261-a8ef-c226b2452e88">Major Axis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b4d85f50-167c-4d59-ad1c-21033494a3db">
                        <link xl:href="http://snomed.info/id/131187009" xl:show="new">G-A193</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf0341ab-82ec-42d2-8363-0c6d63ef2603">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295723" xl:show="new">C1295723</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ca2aa0ed-0636-45bc-ae24-79ecba7dc9bb">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f2327e72-3c13-49d2-9fd3-3f68be3efb79">
                        <link xl:href="http://snomed.info/id/131188004" xl:show="new">131188004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ac49cfcf-19c6-4e77-b1d5-fe50947f3b9a">Minor Axis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2817190f-5fd0-47e0-af66-0e2f2bcf0368">
                        <link xl:href="http://snomed.info/id/131188004" xl:show="new">G-A194</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f992a3e1-f708-4e25-9284-d80f09b82314">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295724" xl:show="new">C1295724</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf5d6ba3-9762-4ead-9151-10ac0b7ed8f0">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f5739ac2-838f-4b35-8b5b-fe59d9a0fd01">
                        <link xl:href="http://snomed.info/id/131189007" xl:show="new">131189007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_04a8cc8a-ff45-43c3-a923-51bb139438e8">Perpendicular Axis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ab00b12f-88a0-44bd-8e35-478d28ed5360">
                        <link xl:href="http://snomed.info/id/131189007" xl:show="new">G-A195</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0f345e8a-b682-4265-b503-eaf2b26169af">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295725" xl:show="new">C1295725</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_12c0d2cb-fdf3-4bb6-a741-5ec1c0ef9ce9">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_964de4e6-8184-4c87-b141-9f6317de78ed">
                        <link xl:href="http://snomed.info/id/131190003" xl:show="new">131190003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_18293b98-66f9-441a-b181-bcd88969d1ee">Radius</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f983ae55-8c52-4f71-b29c-854bf041c151">
                        <link xl:href="http://snomed.info/id/131190003" xl:show="new">G-A196</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2cece962-870c-4951-96b1-4ccae5dfb63b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1306504" xl:show="new">C1306504</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e75c1ad3-652f-419a-ab6e-27e6491289a5">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_33e30405-12bf-4699-89c3-ae43853e95b2">
                        <link xl:href="http://snomed.info/id/131191004" xl:show="new">131191004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_aad4dd37-8d10-4f70-b428-170b763cb6bc">Perimeter</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cad4bb29-db9c-4c5b-9efc-83cedeadd772">
                        <link xl:href="http://snomed.info/id/131191004" xl:show="new">G-A197</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5e2ea613-19bd-4a99-9511-4dc6648922f8">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295726" xl:show="new">C1295726</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d4ad059d-e6ef-49fc-a331-509811a7c040">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8e50255c-2ba1-49f8-84e5-468aaaa428a4">
                        <link xl:href="http://snomed.info/id/74551000" xl:show="new">74551000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_810a0827-cc9a-4173-8cbd-36bfee34e03c">Circumference</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_17d76d1e-0c3e-45e5-bada-166908a27310">
                        <link xl:href="http://snomed.info/id/74551000" xl:show="new">M-02560</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_be610b92-1d9f-4285-a13e-33ef358843a1">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0332520" xl:show="new">C0332520</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6519ef4d-2f56-4573-8cd7-a6fc0b3c7bd2">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cba2ac1a-763a-45c5-bf21-98f0e7bc5590">
                        <link xl:href="http://snomed.info/id/131192006" xl:show="new">131192006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_427c3890-3b1e-4da7-a50e-86960680b3a3">Diameter of circumscribed circle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_050a987a-b3c3-49a7-a920-76c7902c8301">
                        <link xl:href="http://snomed.info/id/131192006" xl:show="new">G-A198</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_80c9896f-db55-4cb0-b0d4-5f08b1b747de">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295727" xl:show="new">C1295727</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9ff42a7f-d809-42d2-8a1a-1b0139b2e260">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8b8028a5-424c-41eb-a802-4c5e838f9eab">
                        <link linkend="DCM_121207" xrefstyle="select: nopage">121207</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9f511551-3ca0-4c4e-bd2e-a7f9c4c8e17f">Height</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a08f7998-26b3-496e-86e4-b85254e38dc8"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_20831e26-e9e3-4101-ad48-53eeeee28eaf"/>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">DCM</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                                <link linkend="DCM_ddd005" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">ddd005</emphasis></emphasis></link>
                            </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Line segment</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para/>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para/>
                    </td>
                </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_277742ae-c0fb-45d7-838d-4b9d293c2431">IBSI</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b3d7b18f-4a33-4e2f-96dc-37dbeb943e34">L0JK</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_622e8915-8cc2-4127-82b4-593dcd93a731">Maximum 3D Diameter of a Mesh</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ffd31c20-2ac2-4fee-943a-d537df63c1bf"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e21aef15-ef34-4c8c-9e24-74b3fdd9a826"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e304838f-13dd-41ca-934f-32f50e2ff9d2">IBSI</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_58123093-1a53-4f32-943f-b6a0fe28f5c3">TDIC</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_2f2a5255-c6a3-4a06-a28e-30817cd75c9d">Major Axis in 3D Length</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9a06bd8f-3a1c-4e9e-8624-67e8c6a29af6"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_86297734-1a4e-407f-8e73-a951d4957656"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5ad29768-d9ca-44c1-9d51-8178238cbbd6">IBSI</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7a4803da-838a-49bb-b9f3-8dd5f207b18f">P9VJ</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ad458704-c041-4944-9c54-a92ae78345a4">Minor Axis in 3D Length</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_00436861-3bc3-4f03-8a67-8abb4a504539"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8fd8e851-9ece-4ee0-87f5-0a34adae99ff"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_75560426-fba9-47e0-a8b4-4f3c54189355">IBSI</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cc2ee7d8-a526-476e-a92d-24b93b5ac43f">7J51</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_865936a5-9dd4-411d-8d58-66a13f8b8fc5">Least Axis in 3D Length</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a389bc10-7234-49a1-ad30-90aa826a5927"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3159eb82-7f31-4f3b-856a-f69e3ce0356b"/>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.16 to add new Context Groups:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="CID ccc1" status="3" xml:id="sect_CID_ccc1">
         <title>Angle Measurements on Images</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>Resources:</term>
               <listitem>
                  <para>
                     <emphasis role="bold">
                         <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_ccc1.html" xl:show="new">HTML</link>
                         | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_ccc1.json" xl:show="new">FHIR JSON</link>
                         | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_ccc1.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu1.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>Type:</term>
               <listitem>
                  <para>
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>Version:</term>
               <listitem>
                  <para>
                     <emphasis role="bold">yyyymmdd</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>UID:</term>
               <listitem>
                  <para>
                     <emphasis role="bold">1.2.840.10008.6.1.uuu1</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         
            <table frame="box" label="CID ccc1" rules="all" xml:id="table_CID_ccc1">
             <caption>Angle Measurements on Images</caption>
             <thead>
                 <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                         <para>Coding Scheme Designator</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                         <para>Code Value</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                         <para>Code Meaning</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                         <para>SNOMED-RT ID</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                         <para>UMLS Concept Unique ID</para>
                     </th>
                 </tr>
             </thead>
             <tbody>
                 <tr valign="top">
                     <td align="center" colspan="1" rowspan="1">
                         <para>SCT</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                         <para>
                             <link xl:href="http://snomed.info/id/285285000" xl:show="new">285285000</link>
                         </para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                         <para>Cobb angle</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                         <para>
                             <link xl:href="http://snomed.info/id/285285000" xl:show="new">F-00E5C</link>
                         </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                         <para>
                             <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0563192" xl:show="new">C0563192</link>
                         </para>
                     </td>
                 </tr>
                 <tr valign="top">
                     <td align="center" colspan="1" rowspan="1">
                         <para>DCM</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                         <para>
                             <link linkend="DCM_ddd002" xrefstyle="select: nopage">ddd002</link>
                         </para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                         <para>Acetabular angle</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                         <para/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                         <para/>
                     </td>
                 </tr>
             </tbody>
         </table>
      </section>
        
        <section label="CID ccc2" status="3" xml:id="sect_CID_ccc2">
            <title>Generic Purpose of Reference to Images and Coordinates in Measurements</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>Resources:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_ccc2.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_ccc2.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_ccc2.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu2.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>Type:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>Version:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>UID:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uuu2</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            
            <table frame="box" label="CID ccc2" rules="all" xml:id="table_CID_ccc2">
                <caption>Generic Purpose of Reference to Images and Coordinates in Measurements</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para>
                                <emphasis role="italic">Include <xref linkend="sect_CID_ccc3" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para>
                                <emphasis role="italic">Include <xref linkend="sect_CID_ccc4" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID ccc3" status="3" xml:id="sect_CID_ccc3">
            <title>Generic Purpose of Reference to Images in Measurements</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>Resources:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_ccc3.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_ccc3.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_ccc3.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu3.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>Type:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>Version:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>UID:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uuu3</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            
            <table frame="box" label="CID ccc3" rules="all" xml:id="table_CID_ccc3">
                <caption>Generic Purpose of Reference to Images in Measurements</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link linkend="DCM_121112" xrefstyle="select: nopage">121112</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Source of Measurement</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/260753009" xl:show="new">260753009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Source</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/260753009" xl:show="new">G-C05F</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0449416" xl:show="new">C0449416</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="CID ccc4" status="3" xml:id="sect_CID_ccc4">
            <title>Generic Purpose of Reference to Coordinates in Measurements</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>Resources:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_ccc4.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_ccc4.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_ccc4.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu4.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>Type:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>Version:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>UID:</term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uuu4</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            
            <table frame="box" label="CID ccc4" rules="all" xml:id="table_CID_ccc4">
                <caption>Generic Purpose of Reference to Coordinates in Measurements</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link linkend="DCM_ddd001" xrefstyle="select: nopage">ddd001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Arm of angle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link linkend="DCM_ddd003" xrefstyle="select: nopage">ddd003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Vector</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link linkend="DCM_ddd004" xrefstyle="select: nopage">ddd004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Approximate spatial location</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.16 to add new codes:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        

        
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            
            
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">Definition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">Notes</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd001">ddd001</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Arm of angle</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>A line segment that is an arm of a pair of arms that defines an angle, whether or not those line segments share a common vertex.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd002">ddd002</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Acetabular angle</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>The angle between a line drawn an AP radiograph of the pelvis horizontally through the inferior aspect of both triradiate cartilages (Hilgenreiner's line) and a line parallel to the acetabular roof.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Used to evaluate developmental dysplasia of the hip.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd003">ddd003</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Vector</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>An entity that has both a magnitude and a direction.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd004">ddd004</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Approximate spatial location</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>The approximate geometric location on an image or in space where an entity is located.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Intended for use when it is known that the source of the information, such as a crude hand-drawn pointer, is in the neighborhood of the entity, but is not expected to be accurate.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd005">ddd005</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Line segment</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>That part of a line (a straight object having no curvature with negligible width and depth) that is bounded by two distinct end points and contains every point on the line between its end points, including both of the two end points.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Derived from <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://en.wikipedia.org/wiki/Line_(geometry)#Line_segment">https://en.wikipedia.org/wiki/Line_(geometry)#Line_segment</link>.</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
    </chapter>
</book>
