<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1961</title>
    <subtitle>Allow more general ultrasound report document titles</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/10/27</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                 xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/07/28</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1961</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Allow more general ultrasound report document titles</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Various ultrasound report templates have single enumerated values for document titles,
                    which is problematic when more specific titles are needed when only partial content is used,
                    and when alternative codes in external schemes become available or need to be used (especially
                    when DCM codes are currently used).</para>
                    <para>Generalize the document titles by using baseline context groups, as well as retiring
                    DCM codes in favor of appropriate external codes.</para>
                    <para><emphasis role="italic">[Ed.Note: Do we want to use synonyms for LOINC terms that include the word "report" (à la CID 7000) and/or are less cryptic, e.g., ""Doppler US of" rather than "US.Doppler"?]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: There does not seem to be LOINC code for vessels without explicit mention of Doppler.]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        
        <section label="TID 5100" status="3" xml:id="sect_TID_5100">
            <title>Vascular Ultrasound Report</title>
            <para xml:id="para_c7129653-1404-4fd3-ac4d-343f6a9f78ec">This is the Template for the root the content tree for the vascular ultrasound proceduhre report.</para>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_4613073c-2142-4dca-a44d-dda6c787458e">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_05152e73-53b1-401c-9cf3-1bcc949d34f7">
                        <emphasis role="bold">Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_5e7e3c51-572b-41f0-b220-53ec17030c0d">
                        <emphasis role="bold">No</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 5100" rules="all" xml:id="table_TID_5100">
               <caption>Vascular Ultrasound Report</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_892c5825-fbe3-49b2-838c-eb4703616af8"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_504173d7-4393-4fd8-8021-af9100b4974d">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_31db01ff-f798-42f0-8707-a5d0f93a2d2a">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9c74b4b3-5f79-4cae-aa7d-2cf08636040c">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_68683e46-2e85-48af-808e-98e00ff84f37">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b727a28b-9072-4586-abcb-059e66499024">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2fe361f1-8561-4e27-b21e-fb7432547850">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_af5c16cc-af69-4619-8861-e186894d7faa">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6ffce94c-8544-442d-8338-378575336c6f">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7af4d315-17d6-4af1-97a0-e883a58a893c">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_44e86df6-0353-42d9-a89c-979d6123a3a6"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5eace2c4-8695-4f16-871f-eb001492c8ec"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_175b23a6-fe1d-4237-b866-10b74c7b489c">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_786cfa65-82d9-49d4-85f6-9828caffc937"><emphasis role="bold"><emphasis role="strikethrough">EV <link linkend="DCM_125100" xrefstyle="select: nopage">(125100, DCM, "Vascular Ultrasound Procedure Report")</link></emphasis><emphasis role="underline">B<xref linkend="sect_CID_ccc01" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                            </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_60790a5f-84d7-4eac-a265-afb2bf163dfb">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f3de121a-66ba-4fd4-b900-993e1b09dfa8">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_46131dd7-1800-46dd-a935-1ef26a5bbd00"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9adb7a25-7e68-49f9-8dba-567a9ffd492c"/>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_97cc3983-4564-4403-b910-e17f7ac6fcab">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_360bac3c-8a47-47d0-b4a1-548b06c93756"><emphasis role="bold"><emphasis role="underline">Row 1</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_caa6764e-43c0-48e2-a241-8c125722cc18"><emphasis role="bold"><emphasis role="underline">Previously, an Enumerated Value of <emphasis role="strikethrough"><link linkend="DCM_125100" xrefstyle="select: nopage">(125100, DCM, "Vascular Ultrasound Procedure Report")</link></emphasis> was specified for the Concept Name. This code has been rertired in favor of codes from external schemes, as well as permitting alternative codes to be used for more specific reports, e.g., for a Carotid Artery report. See PS3.16 20xxz.</emphasis></emphasis></para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>

        
        
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            
            
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">
                                <emphasis role="bold">Definition</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">
                                <emphasis role="bold">Notes</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_125100"><emphasis role="italic">125100</emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_b7d83fd2-1ec0-4faa-b8ba-20af5e8021aa"><emphasis role="italic">Vascular Ultrasound Procedure Report</emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_f0246b3c-26ea-4c05-9f3a-9c0eb171fec6"><emphasis role="italic">Root Document Title for ultrasound vascular evidence reports (worksheets).</emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_ef0ca47b-76c2-4ae2-aeac-212bf5d33716"><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired. replaced by (XXXX, LN, "Vascular Ultrasound").</emphasis></emphasis></emphasis></para>
            </td>
        </tr>
                </tbody>
            </table>
        </section>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new Conext Group to DICOM PS3.16 :</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="CID ccc01" status="3" xml:id="sect_CID_ccc01">
            <title>Vascular Ultrasound Report Document Titles</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_ccc01.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_ccc01.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_ccc01.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu01.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uuu01</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID ccc01" rules="all" xml:id="table_CID_ccc01">
                <caption>Vascular Ultrasound Report Document Titles</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">SNOMED-RT ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://s.details.loinc.org/LOINC/24616-5.html" xl:show="new">24616-5</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>US Carotid arteries<emphasis role="italic"> [Report]</emphasis></para>
                        </td>
                        <td align="center">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0881849" xl:show="new">C0881849</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://s.details.loinc.org/LOINC/46375-2.html" xl:show="new">46375-2</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>US Artery<emphasis role="italic"> [Report]</emphasis></para>
                        </td>
                        <td align="center">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1830089" xl:show="new">C1830089</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://s.details.loinc.org/LOINC/39036-9.html" xl:show="new">39036-9</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>US Vein<emphasis role="italic"> [Report]</emphasis></para>
                        </td>
                        <td align="center">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1543157" xl:show="new">C1543157</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://s.details.loinc.org/LOINC/39445-2.html" xl:show="new">39445-2</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>US.doppler Vessels <emphasis role="italic">[Report]</emphasis></para>
                        </td>
                        <td align="center">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1543521" xl:show="new">C1543521</link>
                            </para>
                        </td>
                    </tr>
                    <tr>
                        <td align="center" colspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/48526000" xl:show="new">48526000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1">Peripheral vascular ultrasound<emphasis role="italic"> [Report]</emphasis></td>
                        <td align="center">
                            <para>
                                <link xl:href="http://snomed.info/id/48526000" xl:show="new">P5-B0111</link>
                            </para>
                        </td>
                        <td align="center" colspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0412527" xl:show="new">C0412527</link>
                            </para>
                        </td>
                    </tr>
                    
                    
                    
                </tbody>
            </table>
        </section>
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference unchanged, DICOM PS3.16 other report title usage:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="TID 2000" status="3" xml:id="sect_TID_2000">
            <title>Basic Diagnostic Imaging Report</title>
            <para xml:id="para_69241d4f-fe25-484d-a1ee-e67ee2494d6b">Basic report Template for general diagnostic imaging interpretation reports.</para>
            <para xml:id="para_eb159548-dfc3-43e0-b384-8abece09223c">Can only be instantiated at the root node and cannot be included in other Templates.</para>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_4ecc5d1d-c868-47f8-bd4a-494c1c70c97c">
                        <emphasis role="bold">Non-Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_be65ea30-c386-4866-831d-08e3441a37f4">
                        <emphasis role="bold">Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_0462a00c-d705-4573-99ec-1e206bdc510c">
                        <emphasis role="bold">Yes</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 2000" rules="all" xml:id="table_TID_2000">
               <caption>Basic Diagnostic Imaging Report</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_97f008fe-9987-4ce2-b139-32b48c69c861"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6b1f54c8-ea91-4c58-aa78-5cefc38189c4">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e650b853-8900-45b3-80ca-1f25a57d805b">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_448c9c5a-248e-42e4-bdfa-70a6ab6a6067">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_57b0ed18-2847-421d-b94f-1294d35bd62f">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_85f60694-14a0-451a-b66c-7d9f1538f6db">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a9f4f574-66a9-43b7-89a4-37883ae69766">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e59cf6ee-2af0-4cbe-8550-e7514897158a">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_efd98bb3-86f5-42d8-9780-faad20880c87">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cfef6f10-5479-47ed-9618-32a48b212299">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_25656471-98ce-4870-bc98-f941d9a9ba46"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_46c21dfd-0518-47a2-b6ec-da590efe5d0f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9b8233f3-a905-46fc-aa27-e593f67c69b5">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ac517288-790e-43ff-bbcb-2fdfdc370ba6">B<xref linkend="sect_CID_7000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4c247dc5-219a-407f-a1a7-c2e2ebd50a63">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_efa17dbe-034a-424d-b76e-925838e0acee">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d8c1300-8cad-4f49-9515-f1e602ed2f4e"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_60eb87e7-d476-40c9-ad80-8383383df7cf">Root node</para>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>
        
        <section label="TID 1500" status="3" xml:id="sect_TID_1500">
            <title>Measurement Report</title>
            <para xml:id="para_451fd560-e4eb-4e0d-bbbe-a2b2bc35cfdb">This Root Template encodes a list of Measurement Groups each containing lists of measurements, together with any derived measurements.</para>
            <para xml:id="para_05032633-832f-4009-aa1a-4cd0169bbcf6">Each Measurement Group is identified by Tracking ID and UIDs.</para>
            <para xml:id="para_ae0f46e9-777b-41b2-9bcb-f73d2d26cdc4">An image library is available to describe characteristics of the images referenced by the measurements, if any.</para>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_dc288621-3a74-4a7d-96e1-b497f9db2c31">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_3d90285a-5fef-466c-a809-b84a2ea3bd77">
                        <emphasis role="bold">Non-Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_554a2a02-c45c-4450-86e5-c176d0b47f9a">
                        <emphasis role="bold">Yes</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 1500" rules="all" xml:id="table_TID_1500">
               <caption>Measurement Report</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7f96ef72-3739-4709-a6f5-d3c609e4ec05"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_eb663436-d709-454e-ac93-98682212c9f0">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6142a93b-0f6d-44a4-8494-fc3299ba7c21">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_81a6fa58-162c-4816-971a-d0a224744ee1">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_97622db7-889d-46d0-a1c0-605bfed0f4c7">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_feb517dd-7464-42f5-9f1d-496753de6be4">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_220e6ae8-5f33-4f58-b426-f41cd8fd2bf4">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9af3785d-8f23-4d07-809d-5639784468c9">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_80f6672b-b0af-4725-adc3-e4e8c7e83695">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3321887d-8899-4314-b289-3d0e04bcdf8f">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fe0e84e0-be0d-437f-8baa-f2478513e5ee"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d8ae3ff8-c9ea-42bf-96e0-2414f44efbcf"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_85dac8a4-19f9-4283-bd59-d51aa905412d">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6e81e20b-a511-403a-893f-29ce62ab8e77">D<xref linkend="sect_CID_7021" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5b5a81ce-2cb2-47bf-9730-858f4fea4387">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0b360053-7fdd-4be5-91bf-eaea1c56d55d">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ca0229a7-7804-4c95-b314-b59248fade6c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c53c5359-96e3-44c4-8875-94dba07faea0">Root node</para>
                     </td>
                  </tr>
                  
                  
                  
                  
                  
                   
                   
                  
                  
                  
                   
                   
                  
                   
                   
                   
                  
               </tbody>
            </table>
            
            
         </section>
        

<section label="CID 7000" status="3" xml:id="sect_CID_7000">
         <title>Diagnostic Imaging Report Document Titles</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_86f2a288-7f01-4854-b489-4182509bedde">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7000.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7000.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7000.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.481.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_e23c07f2-8d91-4bdb-b941-dc288e4c4334">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f62c024d-392a-4bce-8725-7435a9b26f10">
                     <emphasis role="bold">20140102</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_e1b79fe9-da49-4381-b7ba-28ad932da64f">
                     <emphasis role="bold">1.2.840.10008.6.1.481</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7000" rules="all" xml:id="table_CID_7000">
            <caption>Diagnostic Imaging Report Document Titles</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_32b569c3-3a42-4529-9b54-6ecb6e6e6bfb">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c7e35e52-c8fb-4a18-b5e2-55a52c9a59c9">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_039097c8-9d3f-469d-9a28-07599cbc75b0">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e80f0908-c895-4939-8c95-a86617ded568">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_23e746ce-9f26-40d9-849f-681a61ffd7a4">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e8eaf405-621d-4bb2-861e-4deef5754f65">
                        <link xl:href="http://s.details.loinc.org/LOINC/18745-0.html" xl:show="new">18745-0</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_78199b4f-3e77-4a81-8c69-002cd91c5bff">Cardiac Catheterization Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_623b0bb3-8adb-4f53-bf29-3ea98869d258">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801759" xl:show="new">C0801759</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4a1d6e4a-75ef-4aa0-9b0e-cabf8ee245d7">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e8c519f8-c899-4968-99d2-d54201e62c7a">
                        <link xl:href="http://s.details.loinc.org/LOINC/11540-2.html" xl:show="new">11540-2</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_918cbc5e-2279-4827-a7d6-f66bf1e39776">CT Abdomen Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ca5db71c-beaa-4d87-bd63-4c9c8391f991">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0551722" xl:show="new">C0551722</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8b724fee-5978-43d3-b747-01fbc52f9813">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_44081b40-2ede-4c47-8393-f1a0257a6ffd">
                        <link xl:href="http://s.details.loinc.org/LOINC/11538-6.html" xl:show="new">11538-6</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b21e1bbc-cc9a-4cf8-8da7-8e34426eb5f6">CT Chest Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f955f16f-c435-4b1d-acac-8b046d2d9afb">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0551723" xl:show="new">C0551723</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b28d9607-932c-4ec6-9510-91740ac36e8b">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_86c352f6-7715-4de4-b663-afde5122805e">
                        <link xl:href="http://s.details.loinc.org/LOINC/11539-4.html" xl:show="new">11539-4</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6cff99a9-a595-4deb-9e8d-c76766291bdb">CT Head Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8ee42336-f196-443e-94ad-e21a9775d752">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0551724" xl:show="new">C0551724</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cd09bf89-22b3-4390-a9ef-a7f6a084697e">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_27cce705-038d-4605-86c2-a411dba72a1f">
                        <link xl:href="http://s.details.loinc.org/LOINC/18747-6.html" xl:show="new">18747-6</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e90b855c-7159-497e-aa17-9a6c570d33cd">CT Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9dcabf37-c996-4fc8-85e0-085c7b5f3feb">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801761" xl:show="new">C0801761</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7b2f1224-6422-41da-86b9-e62e80578f50">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_380ff44a-1253-4d14-a1e4-a967cc0fc915">
                        <link xl:href="http://s.details.loinc.org/LOINC/18748-4.html" xl:show="new">18748-4</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_2712d5ca-6873-4167-b6df-3df3610c4c4d">Diagnostic Imaging Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1bc4632c-b372-4c63-bbc6-831dd9f81435">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801762" xl:show="new">C0801762</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6dd9027b-2dba-4151-8746-6c5c768d770a">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1b61fb0f-87d8-45ce-a346-1b7497f9e5e9">
                        <link xl:href="http://s.details.loinc.org/LOINC/11522-0.html" xl:show="new">11522-0</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_65f76851-1edf-47fb-a68e-62fb59599101">Echocardiography Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6d382332-d082-49a1-a936-eac0464c1aac">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0551715" xl:show="new">C0551715</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c0ba23b0-2767-4d9d-beb1-24a1f5436e4a">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_31a35cbc-3b69-48a3-aa5a-132d7818a6e8">
                        <link xl:href="http://s.details.loinc.org/LOINC/18760-9.html" xl:show="new">18760-9</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e5ac62d5-924e-44de-a600-c04a276b3241">Ultrasound Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_05e96e67-b95a-4ba4-8167-7a641596f07d">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801774" xl:show="new">C0801774</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5e89cecc-efd0-42be-bf84-1d65ad3de65e">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7412f474-1e8b-4323-8e49-19441edf829e">
                        <link xl:href="http://s.details.loinc.org/LOINC/11541-0.html" xl:show="new">11541-0</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0a47767f-7975-4434-8b96-688cc8d66adc">MRI Head Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_12a8abe9-9d58-464d-8112-a1d7b209f11b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0551725" xl:show="new">C0551725</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e38d9af0-121a-401b-bf3d-469d553b88d7">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5a53d8fb-0ddd-4770-81bd-94f0d13b071a">
                        <link xl:href="http://s.details.loinc.org/LOINC/18755-9.html" xl:show="new">18755-9</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_20add492-dfce-48f1-978e-7f74c89c4f8d">MRI Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c9bbe8cf-fa40-4b69-9f34-3baa9a24fe75">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801769" xl:show="new">C0801769</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6bee9a38-a93c-4452-809f-4750492d1104">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8b5e620e-a281-4946-8a9a-ee3a2ff4d14f">
                        <link xl:href="http://s.details.loinc.org/LOINC/18756-7.html" xl:show="new">18756-7</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6858657e-c217-4bd6-b61e-b44f1eac7624">MRI Spine Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_80209484-9999-429a-b0ec-0848a53cd499">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801770" xl:show="new">C0801770</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2d1582e0-ef4e-454a-91c5-8a6b79cff88f">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_939b6a30-986a-4fa8-8db7-58cc9b72f56f">
                        <link xl:href="http://s.details.loinc.org/LOINC/18757-5.html" xl:show="new">18757-5</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3384a805-4311-4a02-bd2c-a9d325b4865b">Nuclear Medicine Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_176f293e-2475-4b64-ba58-eef47b567633">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801771" xl:show="new">C0801771</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a14915fd-7871-4c2f-b084-891f065f88ce">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_28e4908d-9530-4852-ad8a-d40e6dbecbb5">
                        <link xl:href="http://s.details.loinc.org/LOINC/17787-3" xl:show="new">17787-3</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_57c8a2de-f163-43f4-9bbc-836ec2ece4a9">Nuclear Medicine Thyroid Scan Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_21a4be72-dfd5-449a-9b6a-b8d3f2bd4859">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0800894" xl:show="new">C0800894</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fe2a16c0-0e7d-403e-9ac4-ccbc40c5211c">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_87d431ac-65c7-4b16-b1b4-5f07d6bdb683">
                        <link xl:href="http://s.details.loinc.org/LOINC/11525-3.html" xl:show="new">11525-3</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3bb6aef1-1d43-4e19-bcac-2ad677e1603e">Ultrasound Obstetric and Gyn Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9a75fc14-3835-4005-8a53-c4b9987a06eb">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0551717" xl:show="new">C0551717</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a3c41a66-c007-4405-98cf-dbe64289c3f3">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_48c427b2-4052-44f2-a0ee-bbf2fa690fa2">
                        <link xl:href="http://s.details.loinc.org/LOINC/18758-3.html" xl:show="new">18758-3</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d0608760-f00e-473e-bf32-012b1a35f780">PET Scan Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_24fa9e85-34cf-4c9a-8c9a-9abc4bd67b49">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801772" xl:show="new">C0801772</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_73918f9b-7d20-47fc-9618-d12fd277a850">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_92a1634b-1c07-473e-bbe2-506caadd27bd">
                        <link xl:href="http://s.details.loinc.org/LOINC/11528-7.html" xl:show="new">11528-7</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_db711841-d759-4b0e-ac54-02c6436659c2">Radiology Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ff83ac8d-b386-41b7-a39e-d196711b7630">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0551720" xl:show="new">C0551720</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d6e6438d-8275-4f85-9cb5-12a51cb67595">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f7d93797-35c6-4d14-b3b2-40b0abbe21ef">
                        <link xl:href="http://s.details.loinc.org/LOINC/18750-0.html" xl:show="new">18750-0</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_19ae2489-5af6-491a-97db-d7a60ac6ea0e">Cardiac Electrophysiology Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1300d54f-190f-4336-860b-b2b3ae1b0178">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801764" xl:show="new">C0801764</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ef8da18-c9f9-4be4-a2d8-7745b2b3b329">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cc89e424-2524-4809-ad60-1f776d69775c">
                        <link xl:href="http://s.details.loinc.org/LOINC/11524-0.html" xl:show="new">11524-0</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b0b356a4-d2fb-4c59-abff-6b7763bb022d">ECG Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a98173a7-3424-4b68-9509-19a7067e5842"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5335221f-d4ca-447d-9a16-c2c002029a22">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b92c94b8-f828-409a-9021-2d27d44efba4">
                        <link xl:href="http://s.details.loinc.org/LOINC/18752-6.html" xl:show="new">18752-6</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_af4eb428-89b8-4c02-bd95-17190a393fe9">Exercise Stress Test Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fec7fe18-5eee-466e-a966-a56645fb3428">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801766" xl:show="new">C0801766</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_004220fc-219d-4c5c-88a1-59c9dacdf21c">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_eaa98fc7-c830-44ea-9fdc-8e697178329c">
                        <link xl:href="http://s.details.loinc.org/LOINC/18754-2.html" xl:show="new">18754-2</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c446e294-8ec8-479d-942c-ef28b32c7b02">Holter Study Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5f04b53d-94f9-4a26-90d3-7cca82836af5">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0801768" xl:show="new">C0801768</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_731e3ae9-e85e-4842-9a25-f2df50dee484">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_51537d04-6abf-4c06-a416-3a5e11c3fe6e">
                        <link xl:href="http://s.details.loinc.org/LOINC/43468-8.html" xl:show="new">43468-8</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6c213121-86d5-4829-bd97-289a08b4e99d">X-Ray Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cd892430-f84d-4a0b-9a50-b16eede0039e">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1714805" xl:show="new">C1714805</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dce4f867-f36f-4662-85d4-4fbe81f87a46">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_245a5aae-da23-471e-bfbc-502e4920d4ea">
                        <link xl:href="http://s.details.loinc.org/LOINC/38269-7.html" xl:show="new">38269-7</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9c2eee69-cbac-487c-951c-13da9e89184d">DEXA Skeletal System Study Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_47d2a146-ea5a-407b-979d-42fa8a099542">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1526358" xl:show="new">C1526358</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f4513b2f-7d86-463a-869a-fe3a56d11e41">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_71968926-3bba-4237-8f53-26da2c95e05d">
                        <link linkend="DCM_111400" xrefstyle="select: nopage">111400</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_679444a2-69e5-44e7-89f7-8498504c1619">Breast Imaging Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cd5a69f4-fd5f-40b0-8a9a-c288a9eb0bb0"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8f272476-d588-44c0-91ed-414d2b700958">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_306f3a95-ed9a-4aa9-bc5a-42dd46165bea">
                        <link xl:href="http://s.details.loinc.org/LOINC/24606-6.html" xl:show="new">24606-6</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ea10f396-4145-45b2-ac7a-ed1ca61b61bc">Mammography Screening Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0f047d80-8d9f-4a20-8cbd-67c74c39e6f5">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0881841" xl:show="new">C0881841</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8753c8bb-03fe-447e-9738-a3e684c98c29">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_13dc5ad3-66bd-4998-919a-398154384e87">
                        <link xl:href="http://s.details.loinc.org/LOINC/49512-7.html" xl:show="new">49512-7</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f7eddebf-320d-40d6-b41e-06f7ec093b39">Fluoroscopy Study Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fd07d829-52b8-4f0c-9485-6f4d83fd84ad">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1977263" xl:show="new">C1977263</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_69d005e0-cbdf-419a-8e8d-941599f07d7b">LN</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4cbf9725-3bce-4292-bc86-0a21dbde75dc">
                        <link xl:href="http://s.details.loinc.org/LOINC/47048-4.html" xl:show="new">47048-4</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f3c2627e-4740-4eac-8567-50258d77c58d">Diagnostic Interventional Radiology Report</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_094342f1-d450-4393-a74c-65e86dba34ce">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1831148" xl:show="new">C1831148</link>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
        
        <section label="CID 7020" status="3" xml:id="sect_CID_7020">
            <title>Document Titles</title>
            <para xml:id="para_56bfab58-6d20-45f3-a24b-8489a2f06909">Context Group ID 7020 comprises all document names (i.e., terms with Scale "DOC") within the HIPAA Attachments class of the LOINC coding scheme. The Coding Scheme Designator shall be LN.</para>
            <note>
                <orderedlist numeration="arabic">
                    <listitem>
                        <para xml:id="para_74d91f24-303d-4477-b2fa-7f2e5acf92eb">A subset of this Context Group directly applicable to imaging reports is in <xref linkend="sect_CID_7000" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_cc731c53-0eea-46ea-9e4d-d9707c839390">The LOINC coding scheme can be found at <link xl:href="http://www.regenstrief.org/loinc"/>.</para>
                    </listitem>
                </orderedlist>
            </note>
        </section>
        <section label="CID 7021" status="3" xml:id="sect_CID_7021">
            <title>Measurement Report Document Titles</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1a12e661-4f0b-4d80-9fcb-5aaf8d07ee81">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7021.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7021.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7021.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.997.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_7f698049-990a-4603-b551-19c486e4851a">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_58fd9a94-f9c1-4ebd-9f57-f35bf1f8b3f8">
                            <emphasis role="bold">20141110</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f152dd90-bfaf-45dd-b207-1a6e2f4c3af8">
                            <emphasis role="bold">1.2.840.10008.6.1.997</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7021" rules="all" xml:id="table_CID_7021">
                <caption>Measurement Report Document Titles</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5cb46c7e-0a57-431b-8b2c-9c8137bab8c7">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d539276-38af-490d-99c9-222cf9a25897">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f5a589ce-0031-4916-a189-64d64a9a94c9">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_29cc65a5-a895-4239-9eb6-46948b94c5ff">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2726dccf-c0e8-4659-b039-2e30eff16d4c">
                                <link linkend="DCM_126000" xrefstyle="select: nopage">126000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2fb46714-9a07-48a0-928d-a5a9c32fa6bb">Imaging Measurement Report</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da47966a-4923-4b50-93e0-627671e71efe">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3bf63250-6a86-4500-9b46-d06b2b945aab">
                                <link linkend="DCM_126001" xrefstyle="select: nopage">126001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_89661b0b-56e6-4c31-ae8e-de08f9b1e6d4">Oncology Measurement Report</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66f1a1bd-91c5-4f87-9975-9cf31fd9e527">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5181ad9d-ab40-4d79-8bf6-3e73c91a1dfe">
                                <link linkend="DCM_126002" xrefstyle="select: nopage">126002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ee05538c-4afc-4eae-9e60-4908458d2da4">Dynamic Contrast MR Measurement Report</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_71efe323-fb46-418b-bec2-7e7a4ed6c1e0">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b61e63e-41eb-401e-ac38-c89d78fb9574">
                                <link linkend="DCM_126003" xrefstyle="select: nopage">126003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4610b1fe-3096-48ac-a897-bad936ae9655">PET Measurement Report</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        <section label="CID 12245" status="3" xml:id="sect_CID_12245">
            <title>Cardiac Ultrasound Report Titles</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_45818cdd-e26f-4907-bd53-416302893a09">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_12245.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_12245.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_12245.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.826.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_2f836173-9294-4259-a178-286dbf3de027">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_58eed7a4-fd14-4f09-ab26-4a9d69fb919a">
                            <emphasis role="bold">20100317</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c62426b2-8862-4c95-a8fc-c7a3e867fa99">
                            <emphasis role="bold">1.2.840.10008.6.1.826</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 12245" rules="all" xml:id="table_CID_12245">
                <caption>Cardiac Ultrasound Report Titles</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0d35d203-6059-4917-b9b2-57b70888519c">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d67ad197-9ca2-44f9-ab3f-da9dd324ca0a">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_52693aba-53a6-4e49-96c0-b4fb44f9bd58">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_02e662c9-2b0d-40d6-815e-0216de6cc2fe">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8cb3e74e-437d-4508-9cde-d5166dc74e78">
                                <link linkend="DCM_125195" xrefstyle="select: nopage">125195</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_76d3eb1e-ddd5-4689-922a-eeb811e88d3a">Pediatric Cardiac Ultrasound Report</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3d7f1da-1d1a-459a-aa7c-54c4771bad5a">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66a51eec-f3af-4ced-bda7-0ea77b7c99a5">
                                <link linkend="DCM_125196" xrefstyle="select: nopage">125196</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_640d01dd-0ca0-48ce-a350-12d0dff7fffb">Fetal Cardiac Ultrasound Report</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de7c5587-2739-4547-bcc3-61a0abeaeaa5">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8ef8a99-70d7-44ae-a61f-ca76a5876abf">
                                <link linkend="DCM_125197" xrefstyle="select: nopage">125197</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0cdbea4e-af41-4899-ae95-6ebcc57712a3">Adult Congenital Cardiac Ultrasound Report</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
      


        
        
        
        
        
        
        
        
        
        
        
        
              
      
      

        
        
        
        
        
        
        
        
   

        

        

        
        
        
        
        
        

        
    </chapter>
</book>
