<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1959</title>
    <subtitle>Add codes for more biliary tree structures</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/01/16</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                 xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/07/11</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1959</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add codes for more biliary tree structures</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Only the generic concept for "bile duct" is currently present.</para>
                    <para><emphasis role="italic">[Ed.Note: SNOMED CRS Request ID #745725 for 79741001, 303270005]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="CID 4031" status="3" xml:id="sect_CID_4031">
         <title>Common Anatomic Regions</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_9817a1e5-bf1c-434b-ad09-859df06af9ba">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_4031.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_4031.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_4031.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.308.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_add43dab-8514-43e5-a45b-9b57022e3b84">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_ff02f786-0f11-46df-a874-f0f4a77597ab">
                            <emphasis role="bold"><emphasis role="underline">20170914</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_46adb20e-0e4e-4797-bdb6-8bdcdb686e70">
                     <emphasis role="bold">1.2.840.10008.6.1.308</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 4031" rules="all" xml:id="table_CID_4031">
            <caption>Common Anatomic Regions</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ef2eb0c-9736-49a3-ab01-bad163a04a26">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8f893b26-ee45-4e2f-bbec-c557729f4d3d">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_12d2c962-3231-4bdc-b27f-c577c54dfc91">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5a04e229-5958-47ed-89cb-c9aaba1f534d">
                        <emphasis role="bold">SNOMED-RT ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fc93db94-b47e-465b-9322-003742c0e39e">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0eacc7ea-7001-419f-934b-502eb0e4ab07">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0d4daaca-06bc-41e5-a5b5-8aa1d8433ddc">
                        <link xl:href="http://snomed.info/id/28273000" xl:show="new">28273000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_699263b8-9e6f-49ca-ba7b-406ed6fe0eb7">Bile duct</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bb33b426-5d80-4f62-9923-f18f2c7113d0">
                        <link xl:href="http://snomed.info/id/28273000" xl:show="new">T-60610</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fc5036a7-6992-4918-a22c-9bad7b78dbf4">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0005400" xl:show="new">C0005400</link>
                     </para>
                  </td>
               </tr>
                
                      <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/79741001" xl:show="new"><emphasis role="bold"><emphasis role="underline">79741001</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Common bile duct</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/79741001" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-64500</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0009437" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0009437</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1079e93f-59a1-4a75-b324-07348db6d546">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_74515579-0735-4538-92af-6da2c6c9ee33">
                        <link xl:href="http://snomed.info/id/28231008" xl:show="new">28231008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_28668d04-957c-4aee-bc7f-a77d8a026043">Gallbladder</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a6729795-cbe1-4124-8081-ba3dcb373f98">
                        <link xl:href="http://snomed.info/id/28231008" xl:show="new">T-63000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8e18ef66-9fe8-4ad6-bcef-7d5aafc5c459">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0016976" xl:show="new">C0016976</link>
                     </para>
                  </td>
               </tr>
                
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/303270005" xl:show="new"><emphasis role="bold"><emphasis role="underline">303270005</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Liver and biliary structure</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/303270005" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-50007</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0580674" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0580674</emphasis></emphasis></link>
                        </para>
                    </td>
                </tr>
                
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/15776009" xl:show="new"><emphasis role="bold"><emphasis role="underline">15776009</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Pancreas</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/15776009" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-65000</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0030274" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0030274</emphasis></emphasis></link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/69930009" xl:show="new"><emphasis role="bold"><emphasis role="underline">69930009</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Pancreatic duct</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/69930009" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-65010</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0030288" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0030288</emphasis></emphasis></link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a6b5dd7b-a396-45c3-ad6b-69ba5653c759">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_42a36721-b9dd-4466-8084-a1bac30452c7">
                        <link xl:href="http://snomed.info/id/110621006" xl:show="new">110621006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3209b628-ab04-4c34-a11d-8ebe4dcc929f">Pancreatic duct and bile duct systems</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0eac26b1-6814-440e-904d-c8f8d2219012">
                        <link xl:href="http://snomed.info/id/110621006" xl:show="new">T-65600</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e7611ea9-4610-464b-affc-81d1fa24fbd9">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1267614" xl:show="new">C1267614</link>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
        
        <section label="CID 4040" status="3" xml:id="sect_CID_4040">
         <title>Endoscopy Anatomic Regions</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_75654bfb-c591-4342-a61f-fe0a82070c56">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_4040.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_4040.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_4040.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.311.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_59950a21-9782-4b10-baf2-85a64caf62fc">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_c31f3b6b-71f7-4707-946d-c19f77d482fc">
                            <emphasis role="bold"><emphasis role="underline">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_e5757b97-3b45-41c8-9aa0-3b14c1994701">
                     <emphasis role="bold">1.2.840.10008.6.1.311</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 4040" rules="all" xml:id="table_CID_4040">
            <caption>Endoscopy Anatomic Regions</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2064824e-a807-4325-a819-0934fcdccf50">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_46969e6e-08fe-474b-be1e-b0c7879fdaad">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7a5544aa-973f-48d2-8ad8-bbff7acf6291">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e896d40b-2c08-4a1a-8138-a6e77944bdbb">
                        <emphasis role="bold">SNOMED-RT ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_22494f96-0d87-4e8b-be6a-cccb883d4032">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_db366837-d579-4b75-80d6-a5bd123408b2">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_48df559a-5a74-4312-a75e-06df6188811b">
                        <link xl:href="http://snomed.info/id/28273000" xl:show="new">28273000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_2b414455-df17-4246-97b2-46a21e20886b">Bile duct</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5251427e-ec30-4f73-a163-f7b696be8da2">
                        <link xl:href="http://snomed.info/id/28273000" xl:show="new">T-60610</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_77b9759d-dbc1-46fd-bd33-0c48bc83102c">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0005400" xl:show="new">C0005400</link>
                     </para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/79741001" xl:show="new"><emphasis role="bold"><emphasis role="underline">79741001</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Common bile duct</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/79741001" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-64500</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0009437" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0009437</emphasis></emphasis></link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_93abb25e-325a-49de-bbb2-d55ceb2ea76b">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_acabe719-a089-45cd-88e1-f06d7d3dc859">
                        <link xl:href="http://snomed.info/id/28231008" xl:show="new">28231008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d1b30acd-0843-4f47-b1ca-c213375d3756">Gallbladder</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d3c8d073-8bbe-45f6-9245-e5e96bab6e90">
                        <link xl:href="http://snomed.info/id/28231008" xl:show="new">T-63000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_155410a5-b8cf-4f24-9eff-aed508819794">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0016976" xl:show="new">C0016976</link>
                     </para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/69930009" xl:show="new"><emphasis role="bold"><emphasis role="underline">69930009</emphasis></emphasis></link>
                            </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Pancreatic duct</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/69930009" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-65010</emphasis></emphasis></link>
                            </para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0030288" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0030288</emphasis></emphasis></link>
                            </para>
                    </td>
                </tr>
            </tbody>
         </table>
         <note>
            <orderedlist numeration="arabic">
               <listitem>
                  <para xml:id="para_b14cf7e7-f55c-4f63-be20-4cdd3f564808">See <xref linkend="chapter_I" xrefstyle="template:Annex %n"/> for examples of the relationship between anatomic regions and type of endoscopy performed.</para>
               </listitem>
               <listitem>
                  <para xml:id="para_d712cea1-295d-444d-a3d3-86588655d912">...</para>
               </listitem>
            </orderedlist>
         </note>
      </section>
        
        <section label="CID 7154" status="3" xml:id="sect_CID_7154">
         <title>Abdominal Segmentation Types</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_bb3e5735-ae54-46b6-bbae-38af15052348">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7154.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7154.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7154.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.500.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_a5cb6c30-9785-4f07-b55e-8cb259c0741a">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_1fd88322-9cc5-42b3-b3c2-ceee0fa27314">
                            <emphasis role="bold"><emphasis role="underline">20130617</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f724c996-d27f-478f-91d1-f83319853bfc">
                     <emphasis role="bold">1.2.840.10008.6.1.500</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7154" rules="all" xml:id="table_CID_7154">
            <caption>Abdominal Segmentation Types</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_11991a50-7ca4-4387-8351-175c1e994971">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6a4bc776-41e7-4165-9f32-4abecc6c8dfd">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8e1bd18a-d3e7-4614-988d-16b0a921ccc9">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_db0cf5bd-ce6e-4c1e-8506-00c7de462510">
                        <emphasis role="bold">SNOMED-RT ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_acfe6557-f813-4aee-b6fb-3627b755d0d5">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a7e6ab33-a1b3-4c2c-86f1-5c3ed638946a">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d116b8e7-ef47-4035-834d-d75714bef395">
                        <link xl:href="http://snomed.info/id/28273000" xl:show="new">28273000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e6cea74b-1945-4494-ac17-c9e145adba47">Bile Duct</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d5c30db3-c849-446e-b3c1-751d76f464b3">
                        <link xl:href="http://snomed.info/id/28273000" xl:show="new">T-60610</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_83e3278a-6cc2-48aa-88a8-16b0316a707c">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0005400" xl:show="new">C0005400</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1fd5d5a3-dfd4-460e-bf80-182fd8e2c98a">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5730128e-48e2-4740-8849-2b78e38e8b77">
                        <link xl:href="http://snomed.info/id/10200004" xl:show="new">10200004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e5e03d0e-bd06-426e-a0db-192c34aaba40">Liver</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_eb56ec49-bf68-4ebd-aa05-962ce6e45b8d">
                        <link xl:href="http://snomed.info/id/10200004" xl:show="new">T-62000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a47a90d9-2cc8-4340-98fb-dd4fa554f7f6">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0023884" xl:show="new">C0023884</link>
                     </para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                                <link xl:href="http://snomed.info/id/15776009" xl:show="new"><emphasis role="bold"><emphasis role="underline">15776009</emphasis></emphasis></link>
                            </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Pancreas</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                                <link xl:href="http://snomed.info/id/15776009" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-65000</emphasis></emphasis></link>
                            </para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0030274" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0030274</emphasis></emphasis></link>
                            </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">FMA</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://purl.org/sig/ont/fma/fma17891" xl:show="new"><emphasis role="bold"><emphasis role="underline">17891</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Lumen of gallbladder</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para/>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0736580" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0736580</emphasis></emphasis></link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">FMA</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://purl.org/sig/ont/fma/fma14657" xl:show="new"><emphasis role="bold"><emphasis role="underline">14657</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Wall of gallbladder</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para/>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0734014" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0734014</emphasis></emphasis></link>
                        </para>
                    </td>
                </tr>
            </tbody>
         </table>
      </section>
        
        
        <section label="L" status="1" xml:id="chapter_L">
      <title>Correspondence of Anatomic Region Codes and Body Part Examined Defined Terms</title>
      <table frame="box" label="L-1" rules="all" xml:id="table_L-1">
         <caption>Corresponding Codes and Terms for Human Use</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_77c111ad-ce6f-4ff9-a5fd-1f2804fe3007">
                     <emphasis role="bold">Coding Scheme Designator</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_16f26bbc-9190-4ed2-b3a0-147207725c5b">
                     <emphasis role="bold">Code Value</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_afc02490-4751-4f51-bf8b-3f09d877f25f">
                     <emphasis role="bold">Code Meaning</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_122bb0a4-46bd-4d89-bd1c-a5a83aefa6f2">
                     <emphasis role="bold">Body Part Examined</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_c826bbd1-ed71-4218-8d6f-5a4b0da4c757">
                     <emphasis role="bold">SNOMED-RT ID (Retired)</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5537f494-e5e4-4b4e-bd50-0a11db1eaeaf">
                     <emphasis role="bold">FMA Code Value</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_afa2bf85-c238-45c5-b420-9fe0ede4fb09">
                     <emphasis role="bold">UMLS Concept UniqueID</emphasis>
                  </para>
               </th>
            </tr>
         </thead>
         <tbody>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_abba376a-f036-4482-863f-5446a9b4882d">SCT</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_edd20f7c-0ee4-4c51-81d7-5001e662b090">
                        <link xl:href="http://snomed.info/id/28273000" xl:show="new">28273000</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f7500b49-0eae-479a-a305-612761f1e1d9">Bile duct</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_00aa6839-fa0d-4621-b9b2-d1fdc6f0c35a">BILEDUCT</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7f83fb7a-f72c-4094-9fb5-d12a00e83a72">T-60610</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_8df4030c-f50f-4a8f-afd1-a068195c8261"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5f4ae65e-910d-4b67-b99a-2a01915c7bda"/>
               </td>
            </tr>
             <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para>
                                <link xl:href="http://snomed.info/id/79741001" xl:show="new"><emphasis role="bold"><emphasis role="underline">79741001</emphasis></emphasis></link>
                            </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Common bile duct</emphasis></emphasis></para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">COMMONBILEDUCT</emphasis></emphasis></para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-64500</emphasis></emphasis></para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0009437" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0009437</emphasis></emphasis></link>
                     </para>
                 </td>
             </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_2808d883-89a8-4569-a79c-959c6ab78bf6">SCT</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_2b056210-3114-4bbd-b0d4-c877af4cbf1b">
                        <link xl:href="http://snomed.info/id/28231008" xl:show="new">28231008</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1eca5e13-139a-49d3-94af-5d30c01abd8b">Gallbladder</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9f752090-50d3-4b58-8fa5-3647d9a49667">GALLBLADDER</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_90a91674-aae1-401b-8a5f-9d51a0d5c920">T-63000</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a31d3ae2-b107-4f57-8439-0583ea724d7e"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_2f869df9-a9c7-4cd0-9adc-da92031f6296"/>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_19af1171-3266-4618-b932-fe2771668fd1">SCT</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_797788c0-c4fe-45d6-9649-e4fce771ba78">
                        <link xl:href="http://snomed.info/id/10200004" xl:show="new">10200004</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_67788b9a-3222-49e6-a26b-8d857370b116">Liver</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_642db26c-17a6-4149-acf4-e9f0656863f4">LIVER</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_adca4fee-05cc-4f99-8b17-fcf315b40389">T-62000</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_542269b6-600d-412c-aaf2-8337102e46f4"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_09e95d27-d200-4343-86e3-ba01278c017b"/>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_b0399432-c8fe-410f-b85c-224c61a7fdfc">SCT</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_29513eea-a907-416a-ac84-ab14a622a64a">
                        <link xl:href="http://snomed.info/id/15776009" xl:show="new">15776009</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_cbda13d0-a165-418e-8cb3-2daee10dede8">Pancreas</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d75286a3-c5d1-430a-82f3-af69cddcc816">PANCREAS</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_07758ae9-6253-4f0b-ae63-93b4ae2e2d3a">T-65000</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ef05563b-0c1e-4740-8b03-45802c23007a"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_03273566-bc7c-4b88-9292-cd95876adf6e"/>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_2403eed3-364f-4b9c-b599-41ea87ef3004">SCT</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d538917e-fe9d-4395-9a5d-572f1d70d23e">
                        <link xl:href="http://snomed.info/id/69930009" xl:show="new">69930009</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6dd0761a-36d6-421c-a43a-778047891e1c">Pancreatic duct</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a058b4ba-3cd1-4cb2-b6a8-83d5e1ef10ac">PANCREATICDUCT</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e20efa85-4ecd-4d4a-8db0-cb90642efe41">T-65010</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d88c8e39-3c74-425b-861a-f9d992ba8d8e"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_89620db0-0d15-4cda-9e04-7d038620b226"/>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f1f32496-db13-43b9-a893-2461c7134826">SCT</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_2881dfd6-26b7-4d00-8a6c-f21090df2a08">
                        <link xl:href="http://snomed.info/id/110621006" xl:show="new">110621006</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_4a2b9245-311a-4346-a861-b23eccab4f7b">Pancreatic duct and bile duct systems</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_95233a8d-2289-497c-8078-8d5efccfeba0"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_92cb2cfd-2a36-4935-afba-a0f92ce7b7fe">T-65600</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e867648c-a27d-4f26-884f-28b79627f85f"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_3a3cc630-1504-4178-9b8a-c19ddab07507"/>
               </td>
            </tr>
         </tbody>
      </table>
      <table frame="box" label="L-5" rules="all" xml:id="table_L-5">
         <caption>Pairedness of Anatomic Concepts</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_58a2c614-e5bd-46f9-817c-18de5244665d">
                     <emphasis role="bold">SNOMED Code Value</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_08643174-d49f-4487-aa37-61c7096ec0f5">
                     <emphasis role="bold">Code Meaning</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a6b9b7b0-0fc2-4297-a36e-abd367bb51fd">
                     <emphasis role="bold">Paired Structure</emphasis>
                  </para>
               </th>
            </tr>
         </thead>
         <tbody>
             <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f63f0144-f1a1-443c-835b-ba5aeb58579e">
                        <link xl:href="http://snomed.info/id/28273000" xl:show="new">28273000</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_93615ef7-c3a6-4fe9-90ee-8570ff175db8">Bile duct</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e200ee2a-5907-4f17-afc9-5d916068ac9a">N</para>
               </td>
            </tr>
             <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://snomed.info/id/79741001" xl:show="new"><emphasis role="bold"><emphasis role="underline">79741001</emphasis></emphasis></link>
                            </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Common bile duct</emphasis></emphasis></para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                 </td>
             </tr>
             <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_0607c974-56de-4ea0-ad0b-c68ef0b55488">
                        <link xl:href="http://snomed.info/id/28231008" xl:show="new">28231008</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_34dad4a1-6661-4be1-8e6d-c2f0041550f4">Gallbladder</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_af37cfd0-190c-4672-b34f-7305fe2f8c51">N</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_0110f375-b94a-4b1c-a776-4c72429b4d86">
                        <link xl:href="http://snomed.info/id/10200004" xl:show="new">10200004</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_4c4ad841-10d7-4911-aa00-e3a32b529060">Liver</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_64eee11b-261d-4228-bd9e-cfc6dc88c751">N</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_2ba2fe3e-616e-439c-a0f5-c9c65fe3360f">
                        <link xl:href="http://snomed.info/id/15776009" xl:show="new">15776009</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e6d654a7-d13c-4d15-b913-1b6bf41614fe">Pancreas</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e8c5eb43-9b68-4d1d-8c4b-8269950b6edd">N</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_04d1b362-a496-4057-95af-89cbaeb28c15">
                        <link xl:href="http://snomed.info/id/69930009" xl:show="new">69930009</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a41cc9ec-d0d5-4e30-b6b9-85308aaef964">Pancreatic duct</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_18d372e3-4d33-496f-a69a-063d279e0696">N</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_bd0f51e3-1f4c-49f7-b9b0-e6fef77165d2">
                        <link xl:href="http://snomed.info/id/110621006" xl:show="new">110621006</link>
                     </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_afb5e60a-c59d-42c4-95cc-38dd7d8a970e">Pancreatic duct and bile duct systems</para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d9477f3a-57e9-444b-b99b-ff2e0efe6ac9">N</para>
               </td>
            </tr>
            <tr>
               <td align="center" colspan="1" rowspan="1"/>
               <td align="left" colspan="1"/>
               <td align="center" colspan="1" rowspan="1"/>
            </tr>
         </tbody>
      </table>
   </section>
        
        
        
        
        
        
        
              
      
      

        
        
        
        
        
           
   



        

        
        
        
        
        
        

        
    </chapter>
</book>