<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1933</title>
    <subtitle>Add PIRADS V2.1 base PZpm sector anatomy</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/11/08</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/03/20</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1933</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add PIRADS V2.1 base PZpm sector anatomy</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.6,3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Add PIRADS V2.1 adds a new right and left sector PZpm.</para>
                    <para><emphasis role="italic">[Ed.Note: SNOMED Request ID 747176.]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 by adding new context group:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        <section label="CID 63nn" status="3" xml:id="sect_CID_63nn">
            <title>Prostate Sector Anatomy from PI-RADS v2.1</title>
            <note>
                <para>From <xref linkend="biblio_PIRADS21"/>.</para>
            </note>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_63nn.html" xl:show="new">HTML</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_63nn.json" xl:show="new">FHIR JSON</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_63nn.xml" xl:show="new">FHIR XML</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuuu.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uuuu</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 63nn" rules="all" xml:id="table_CID_63nn">
                <caption>Prostate Sector Anatomy from PI-RADS v2.1</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">SNOMED-RT ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">FMA ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">PI-RADS v2.1 Abbreviation</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">NCI Thesaurus</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="8" rowspan="1">
                            <para>
                                <emphasis role="italic">Include <xref linkend="sect_CID_6301" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr>
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/TBD" xl:show="new">TBD</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Left posteromedial basal peripheral zone of prostate</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para> </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=TBD" xl:show="new">TBD</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=TBD" xl:show="new">TBD</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>Base L PZpm</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=TBD" xl:show="new">TBD</link>
                            </para>
                        </td>
                    </tr>
                    <tr>
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/TBD" xl:show="new">TBD</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Right posteromedial basal peripheral zone of prostate</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para> </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=TBD" xl:show="new">TBD</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=TBD" xl:show="new">TBD</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>Base R PZpm</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=TBD" xl:show="new">TBD</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="2" status="1" xml:id="chapter_2">
            <title>Normative References</title>
            <bibliography>
                <title/>
        <bibliodiv label="2.20" status="2" xml:id="sect_2.20">
            <title>Prostate Reporting Terminology and Nomenclature</title>
            <para xml:id="para_cdfe3ded-7367-499d-b0fa-d5392c898a6c"> The Prostate Imaging and Report and Data System <emphasis role="bold"><emphasis role="strikethrough">Version 2 </emphasis></emphasis>(PI-RADS<emphasis role="bold"><emphasis role="strikethrough"> v2</emphasis></emphasis>) is a joint effort of the European Society of Urogenital Radiology, the American College of Radiology and the AdMetech Foundation.</para>
            <biblioentry xml:id="biblio_PIRADS">
                <abbrev>PI-RADS v2</abbrev>
                <biblioset relation="journal">
                    <title>Eur Urol</title>
                </biblioset>
                <biblioset relation="article">
                    <authorgroup>
                        <author>
                            <personname>Weinreb JC</personname>
                        </author>
                        <author>
                            <personname>Barentsz JO</personname>
                        </author>
                        <author>
                            <personname>Choyke PL</personname>
                        </author>
                        <author>
                            <personname>Cornud F</personname>
                        </author>
                        <author>
                            <personname>Haider MA</personname>
                        </author>
                        <author>
                            <personname>Macura KJ</personname>
                        </author>
                        <author>
                            <personname>Margolis, D</personname>
                        </author>
                        <author>
                            <personname>Schnall, MD</personname>
                        </author>
                        <author>
                            <personname>Shtern, F</personname>
                        </author>
                        <author>
                            <personname>Tempany, CM.</personname>
                        </author>
                        <author>
                            <personname>Thoeny, HC</personname>
                        </author>
                        <author>
                            <personname>Verma, S</personname>
                        </author>
                    </authorgroup>
                    <date>2016/01</date>
                    <volumenum>69</volumenum>
                    <issuenum>1</issuenum>
                    <pagenums>16-40</pagenums>
                    <title>PI-RADS Prostate Imaging - Reporting and Data System: 2015, Version 2</title>
                    <biblioid class="doi">10.1016/j.eururo.2015.08.052</biblioid>
                    <bibliosource>
                        <link xl:href="http://www.europeanurology.com/article/S0302-2838%2815%2900848-9/"/>
                    </bibliosource>
                </biblioset>
            </biblioentry>
            
            <biblioentry xml:id="biblio_PIRADS21">
                        <abbrev><emphasis role="underline">PI-RADS v2.1</emphasis></abbrev>
                        <biblioset relation="journal">
                            <title><emphasis role="bold"><emphasis role="underline">Eur Urol</emphasis></emphasis></title>
                        </biblioset>
                        <biblioset relation="article">
                            <authorgroup>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Turkbey B</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Rosenkrantz AB</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Haider MA</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Padhani AR</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Villeirs G</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Macura KJ</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Tempany, CM</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Choyke PL</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Cornud F</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Margolis, D</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Thoeny, HC</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Verma, S</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Barentsz JO</emphasis></emphasis></personname>
                                </author>
                                <author>
                                    <personname><emphasis role="bold"><emphasis role="underline">Weinreb JC</emphasis></emphasis></personname>
                                </author>
                            </authorgroup>
                            <date><emphasis role="bold"><emphasis role="underline">2019/03</emphasis></emphasis></date>
                            <volumenum/>
                            <issuenum/>
                            <pagenums/>
                            <title><emphasis role="bold"><emphasis role="underline">Prostate Imaging Reporting and Data System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2</emphasis></emphasis></title>
                            <biblioid class="doi">10.1016/j.eururo.2019.02.033</biblioid>
                            <bibliosource>
                                <link xl:href="http://www.europeanurology.com/article/S0302-2838(19)30180-0/abstract"/>
                            </bibliosource>
                        </biblioset>
                    </biblioentry>

            
            
            <note>
                <para xml:id="para_9f46fcec-ffde-445a-8216-89a6716b9cab">PI-RADS is also available from the following sources:
                    <itemizedlist>
                        <listitem>
                            <para xml:id="para_5d3b28fa-b951-4a5d-8492-bde3ada78d1a">American College of Radiology: <link xl:href="http://www.acr.org/~/media/ACR/Documents/PDF/QualitySafety/Resources/PIRADS/PIRADS%20V2.pdf"/>
                            </para>
                        </listitem>
                    </itemizedlist>
                </para>
            </note>
            <biblioentry xml:id="biblio_ProstateEuConcensus">
                <abbrev>Prostate Eu Concensus</abbrev>
                <biblioset relation="journal">
                    <title>Eur Urol</title>
                </biblioset>
                <biblioset relation="article">
                    <authorgroup>
                        <author>
                            <personname>Dickinson L</personname>
                        </author>
                        <author>
                            <personname>Ahmed HU.</personname>
                        </author>
                        <author>
                            <personname>Allen C</personname>
                        </author>
                        <author>
                            <personname>Barentsz JO</personname>
                        </author>
                        <author>
                            <personname>Carey B</personname>
                        </author>
                        <author>
                            <personname>Futterer JJ</personname>
                        </author>
                        <author>
                            <personname>Heijmink SW</personname>
                        </author>
                        <author>
                            <personname>Hoskin PJ</personname>
                        </author>
                        <author>
                            <personname>Kirkham A</personname>
                        </author>
                        <author>
                            <personname>Padhani AR</personname>
                        </author>
                    </authorgroup>
                    <date>2011</date>
                    <volumenum>59</volumenum>
                    <issuenum>4</issuenum>
                    <pagenums>477-94</pagenums>
                    <title>Magnetic resonance imaging for the detection, localisation, and characterisation of prostate cancer: recommendations from a European consensus meeting</title>
                    <biblioid class="doi">10.1016/j.eururo.2010.12.009</biblioid>
                    <bibliosource>
                        <link xl:href="http://www.europeanurology.com/article/S0302-2838(10)01187-5/"/>
                    </bibliosource>
                </biblioset>
            </biblioentry>
            <biblioentry xml:id="biblio_ESURGuidelines">
                <abbrev>ESUR Guidelines</abbrev>
                <biblioset relation="journal">
                    <title>Eur Radiol</title>
                </biblioset>
                <biblioset relation="article">
                    <authorgroup>
                        <author>
                            <personname>Barentsz JO</personname>
                        </author>
                        <author>
                            <personname>Richenberg J</personname>
                        </author>
                        <author>
                            <personname>Clements R</personname>
                        </author>
                        <author>
                            <personname>Choyke P</personname>
                        </author>
                        <author>
                            <personname>Verma S</personname>
                        </author>
                        <author>
                            <personname>Villeirs G</personname>
                        </author>
                        <author>
                            <personname>Rouviere O</personname>
                        </author>
                        <author>
                            <personname>Logager V</personname>
                        </author>
                        <author>
                            <personname>Fütterer JJ</personname>
                        </author>
                    </authorgroup>
                    <date>2012/04</date>
                    <volumenum>22</volumenum>
                    <issuenum>4</issuenum>
                    <pagenums>746-57</pagenums>
                    <title>ESUR prostate MR guidelines 2012</title>
                    <biblioid class="doi">10.1007/s00330-011-2377-y</biblioid>
                    <bibliosource>
                        <link xl:href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3297750/">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3297750/</link>
                    </bibliosource>
                </biblioset>
            </biblioentry>
        </bibliodiv>
            </bibliography>
        </section>
        <section label="CID 6300" status="3" xml:id="sect_CID_6300">
            <title>Prostate Sector Anatomy</title>
            <note>
                <para xml:id="para_0b0279f2-12b8-47b5-be0d-dc4d859285d0">In future extensions, Prostate Sector Anatomy terms that are not derived from PI-RADS <emphasis role="bold"><emphasis role="strikethrough">v2 </emphasis></emphasis>should be added to this context group.</para>
            </note>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_080681d6-9c79-4f54-ad06-62948324ba12">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6300.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_6300.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_6300.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1138.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_b272a931-be82-4bc2-9fe8-d9482cf9a17a">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ec7cebb6-12ca-4b77-9123-22ba4c68a5ee">
                            <emphasis role="bold"><emphasis role="strikethrough">20161106</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ea6ce80f-7a72-4cb1-812b-7f21ddd25524">
                            <emphasis role="bold">1.2.840.10008.6.1.1138</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 6300" rules="all" xml:id="table_CID_6300">
                <caption>Prostate Sector Anatomy</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f337b9a-cc9b-41f0-8761-5c5ab091e04b">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2a606bd-8545-4277-bdc2-e766539fc3ea">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_68b99ff4-13c0-40b7-95dd-f5a1742a4d97">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_9e4e30fa-c7b5-43ca-9e7c-90462831853c">
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="strikethrough">Include <xref linkend="sect_CID_6301" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                                </emphasis>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_63nn" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_7d565ad7-24a4-4097-bd8e-a4b62381e886">
                                <emphasis role="italic">Include <xref linkend="sect_CID_6302" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_0b4978a8-4714-4c72-89b9-0325b8c963e9">
                                <emphasis role="italic">Include <xref linkend="sect_CID_6303" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 6301" status="3" xml:id="sect_CID_6301">
         <title>Prostate Sector Anatomy from PI-RADS v2</title>
         <note>
            <para xml:id="para_ec341c60-ae4a-4090-ba41-3f9de05d1e3e">From <xref linkend="biblio_PIRADS"/>.</para>
         </note>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_38a5d319-4603-433e-a8b5-45d856b81228">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6301.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_6301.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_6301.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1139.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_1a027939-eb8d-4fe1-8d20-030f0fcb6373">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_cd53d267-f497-4fb8-953a-c97eb95e2b79">
                     <emphasis role="bold">20161106</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_0f72d914-63fe-46a4-a772-d6669e185267">
                     <emphasis role="bold">1.2.840.10008.6.1.1139</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 6301" rules="all" xml:id="table_CID_6301">
            <caption>Prostate Sector Anatomy from PI-RADS v2</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4bd3beb0-b880-455e-a8cf-f6f67732b997">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_574097f1-6658-4152-8fc5-4a0dc8e8ccaa">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_11cf5ba6-e138-4728-b6e2-b2f8c5812078">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b66c8cd5-2b6c-458a-bf43-6ae3d474d43f">
                        <emphasis role="bold">SNOMED-RT ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_526997f7-b54e-4e79-820e-d5472e7b1b0e">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3ae90e49-442c-465b-89af-aa992b800e4d">
                        <emphasis role="bold">FMA ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d927500b-3360-4035-976d-13c42799c451">
                        <emphasis role="bold">PI-RADS v2 Abbreviation</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2064f96e-34a6-4735-8cf7-16bdc5717aea">
                        <emphasis role="bold">NCI Thesaurus</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_995991ec-3cf4-4faa-a652-f37cfa1d9dcf">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_73d0aefe-8442-4333-a1c0-52c8b25b6049">
                        <link xl:href="http://snomed.info/id/716901006" xl:show="new">716901006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c411b583-1e7d-42c1-a73c-b9bcfa0ef5c7">Central zone of left half prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_42944c77-4990-424e-937f-fce306ee310a">
                        <link xl:href="http://snomed.info/id/716901006" xl:show="new">R-FFFFC</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6efe9f73-901d-4d9d-aa91-d18b6a7933a1">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273550" xl:show="new">C4273550</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_83b31cb6-2af3-468f-bb65-7a0e4f04a58a">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=302475" xl:show="new">302475</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_320f68d1-211b-4895-aede-6b7579aeae31">Base L CZ</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_69592184-a158-4b26-8148-f61650a582f2">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128587" xl:show="new">C128587</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e6a9f632-5fe8-4dbb-ab3e-28ea5d556711">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_56cb3fb1-fdcb-4f23-8b73-bcdbe707829f">
                        <link xl:href="http://snomed.info/id/716900007" xl:show="new">716900007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c0660ea0-422c-4164-9f7a-41d5667010ef">Central zone of right half prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_669aa1b9-1ba0-48bf-b7b4-8a3a462c339b">
                        <link xl:href="http://snomed.info/id/716900007" xl:show="new">R-FFFD0</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d26c53d0-0729-4313-adcc-cc64f9df649f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274157" xl:show="new">C4274157</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_94b23dd7-d0c4-4538-881c-be5826ce178a">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=302473" xl:show="new">302473</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5981c6be-b3f0-47af-aa1a-ecdc7454090c">Base R CZ</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3ae75478-0f78-4da9-9aa7-fd6e984703ea">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128593" xl:show="new">C128593</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cab04cbf-8a6b-4186-af25-fe6ef7a27e59">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e137923b-37b9-4812-befb-4117ccdce0ed">
                        <link xl:href="http://snomed.info/id/716937001" xl:show="new">716937001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1fe0ca13-9ec5-4a93-9019-d495fe969d3a">Left anterior apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ed26a279-0a48-444a-8102-b88e15c71e4d">
                        <link xl:href="http://snomed.info/id/716937001" xl:show="new">R0-00025</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_38f19d6b-413e-4474-b30a-8f022de8441e">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274170" xl:show="new">C4274170</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_39b150d2-8bc4-4b45-8164-16ef523ee467">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328760" xl:show="new">328760</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5ca80f67-23b6-4be3-a7ae-5565a79d6729">Apex L PZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3c9aab80-ffda-4627-9142-497f9ea0f800">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128575" xl:show="new">C128575</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_78eb5d76-bdc3-49e3-ae6b-b30f921efcd0">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0abe3351-668f-4c91-baae-934ddc279a6b">
                        <link xl:href="http://snomed.info/id/716931000" xl:show="new">716931000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_65a5fc48-9490-42ff-8643-094c1e5dda11">Left anterior apical transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e6c1893c-601d-4102-bd48-c182ec9837ce">
                        <link xl:href="http://snomed.info/id/716931000" xl:show="new">R-FFFE5</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7d264ab4-dec4-460e-804c-838ad52ad318">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274174" xl:show="new">C4274174</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_56e550bd-41ed-4bd7-a64d-0eb03ddb3c44">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328795" xl:show="new">328795</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9f4e932d-3bcb-4d0a-956d-878fefa6706f">Apex L TZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ff730b6a-9f19-46d9-a6cf-27605e81d6aa">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128578" xl:show="new">C128578</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_742a2bd3-2ff5-4cc7-ab37-8e0a28b44408">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d1420f0e-f2e8-48e4-9ee2-c81a533543ed">
                        <link xl:href="http://snomed.info/id/716905002" xl:show="new">716905002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9cf5b88e-78a1-402a-9308-91ec44949a9a">Left anterior basal peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0bca9b1f-bfe7-4a78-a14e-7f2bc40392db">
                        <link xl:href="http://snomed.info/id/716905002" xl:show="new">R0-00001</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a5157fca-752f-41a9-87f5-14abb65c5c7d">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273857" xl:show="new">C4273857</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1a96d7ed-fc57-46ba-89c8-e9066f6b8e5b">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328753" xl:show="new">328753</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c3384f8b-1f8d-436f-999b-ab877649c3a9">Base L PZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4fabc9c7-b542-4c94-b11f-312774be2c85">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128588" xl:show="new">C128588</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_432f4575-1291-421e-9117-d4425157a2ae">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d5b0a9cb-dc14-4865-a00d-341a41e92f39">
                        <link xl:href="http://snomed.info/id/716897000" xl:show="new">716897000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_48ce0336-5cd9-432e-9fd9-7c084ba5a7f5">Left anterior basal transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3876cba5-d9ef-4dac-a8bd-957020d3864b">
                        <link xl:href="http://snomed.info/id/716897000" xl:show="new">R-FFFD6</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_19768b68-d15b-4fe5-83a5-c27592ac14e7">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274207" xl:show="new">C4274207</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c7f9645f-e97b-4cb2-bdd7-9fa6229f91f5">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328785" xl:show="new">328785</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_948750d5-c11a-4913-95d1-e05a2cc51ca8">Base L TZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_190a5235-dbf6-4e9a-9775-527fe600f938">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128589" xl:show="new">C128589</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_21d4ccd5-4212-4c6c-9d98-0e6e78ae1a70">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2ce33a41-432e-4fa6-997d-9f9f805729c9">
                        <link xl:href="http://snomed.info/id/716920008" xl:show="new">716920008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a9cb480e-61d4-4c4e-a583-2b0fb2f0fe1b">Left anterior middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7f3f29de-c844-48f5-8553-46578b5a7094">
                        <link xl:href="http://snomed.info/id/716920008" xl:show="new">R-FFFB0</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_eddbf4e3-a942-45fd-84b7-455bc3e13a08">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274185" xl:show="new">C4274185</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7c8dec80-d213-4230-a7f0-b904dcd079d7">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328768" xl:show="new">328768</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a855ac46-dfe5-4d17-82b0-1a6cd0d6699c">Mid L PZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ae509eb7-a8b1-40fe-9c4c-29d4ba981c68">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128600" xl:show="new">C128600</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_349fd803-d7e5-4b2e-970c-e610911e8127">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_da42be45-aa54-4426-89c9-af9036d9dd06">
                        <link xl:href="http://snomed.info/id/716914007" xl:show="new">716914007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4aa086dd-6c15-48fa-9ff0-df3f2770813d">Left anterior middle transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_eb29a487-93e2-45b4-9fd7-9dc9c7b33783">
                        <link xl:href="http://snomed.info/id/716914007" xl:show="new">R0-00013</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5fe62e80-d890-4b7c-9a02-283aeb415c3f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274190" xl:show="new">C4274190</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a774eeb4-c604-4480-a87d-5e91bc72b8d0">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328784" xl:show="new">328784</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b3cc20d3-2e2c-4bbb-ae40-26c4afc95fa7">Mid L TZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3218acc2-b210-4e9f-910c-3278735310a3">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128603" xl:show="new">C128603</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c466f657-9fbb-4d72-8a5e-4a01178646f7">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d5b60c4e-5a2b-4db3-874a-d80bc33e6c16">
                        <link xl:href="http://snomed.info/id/716927006" xl:show="new">716927006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_270c7ff0-c5d8-4fd4-bd0c-27533967abae">Left apical anterior fibromuscular stroma of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4c3d2769-686a-4045-a6cd-1f25e7f96e3c">
                        <link xl:href="http://snomed.info/id/716927006" xl:show="new">R-FFFDF</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bef3477c-beae-4922-ba24-96e15fa87c3e">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274178" xl:show="new">C4274178</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b0f88b27-8715-457d-ab03-e9c12c518726">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328772" xl:show="new">328772</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ce3c00ce-6915-425c-9e92-949e5a8e07ca">Apex L AS</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c335d0b8-3d31-4ece-a49a-65d0e0cdce35">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128574" xl:show="new">C128574</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e15280fa-4f4f-4ef6-8553-787e1a2d0c7c">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d62380ba-5b7c-4606-9076-b2657349ae0f">
                        <link xl:href="http://snomed.info/id/716893001" xl:show="new">716893001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_dd79f67d-0257-4291-97ea-2b33aeb986ff">Left basal anterior fibromuscular stroma of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1936b675-3da7-446c-9c7e-6a266048394a">
                        <link xl:href="http://snomed.info/id/716893001" xl:show="new">R-FFFDC</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_25a068ae-02c5-4a52-9a30-83b8f1503c0f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274482" xl:show="new">C4274482</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_22bff95f-ae53-42ed-87c1-cd72a4595c0f">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328758" xl:show="new">328758</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c56cea24-db74-4028-981f-b891eb4bebd4">Base L AS</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c08d7adc-d0fd-4c0a-9a95-dae783775caf">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128586" xl:show="new">C128586</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ea2029b7-5f6f-42e4-8bd6-71e946d33107">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_14b91ad2-7045-4f8c-89de-307b6dbeddd1">
                        <link xl:href="http://snomed.info/id/716910003" xl:show="new">716910003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_408c37a7-446a-44a2-bb30-d3b1910453bb">Left middle anterior fibromuscular stroma of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0f4c67e4-23eb-4fe4-b455-cbd960d3f63b">
                        <link xl:href="http://snomed.info/id/716910003" xl:show="new">R0-00027</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a1ea73e1-a161-4cd5-9ecd-72283c2f9bc9">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274479" xl:show="new">C4274479</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_71bd0284-0e6b-454e-a1ca-468d8997abaf">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328781" xl:show="new">328781</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_70c3e9a2-df2f-42ea-9706-e266a06e996c">Mid L AS</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5672f3f7-c9fa-4467-b5d0-084c3834a5de">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128599" xl:show="new">C128599</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf80ccd1-0647-4ee5-9fd4-039433020c60">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b30675b8-e4d7-4ce0-a372-bcf178bca9e1">
                        <link xl:href="http://snomed.info/id/716933002" xl:show="new">716933002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6ed1d09d-0ee5-4d0b-94b7-57e3d1c8dbe6">Left posterior apical transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_380c87ef-8ad4-4576-930f-b17e5f25ec48">
                        <link xl:href="http://snomed.info/id/716933002" xl:show="new">R0-00014</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_312ea5fd-cc23-4918-8158-b2d5b60be25c">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274173" xl:show="new">C4274173</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c64c8a7f-689c-40e1-b392-375f0946d81e">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328775" xl:show="new">328775</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7da6b101-052b-4718-9121-b4ee69ee1974">Apex L TZp</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_48fa7b5b-836d-4096-88d6-deb79232eda8">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128579" xl:show="new">C128579</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_91c9e17b-8427-4fb2-9be4-89edf07feb45">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_63bbeb46-1b93-4013-b06e-bb74a59d8564">
                        <link xl:href="http://snomed.info/id/716899002" xl:show="new">716899002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d67e516d-91be-419e-a4db-e6bf8f849177">Left posterior basal transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_95463b0e-b880-410d-b17e-8ff9bb063d44">
                        <link xl:href="http://snomed.info/id/716899002" xl:show="new">R-FFFB7</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a126771e-ebec-4209-8938-008741f2451a">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274204" xl:show="new">C4274204</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_08b5f726-0bdc-4cbb-8fa2-5266911d0d8b">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328789" xl:show="new">328789</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c7703b0e-d5bd-419f-aaed-8aa0c55744fc">Base L TZp</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3f44ec79-4016-4065-a2ac-bb7d795a4fa5">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128590" xl:show="new">C128590</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a3555ab9-0378-40be-ba8b-10170db16d86">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e94779f6-17c8-4981-a2d6-514e4f1c7790">
                        <link xl:href="http://snomed.info/id/716916009" xl:show="new">716916009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_23e40196-2a9b-4173-9143-3cde077a60a4">Left posterior middle transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_54dfcded-97a0-443b-aa99-0f2f58c5a4ca">
                        <link xl:href="http://snomed.info/id/716916009" xl:show="new">R-FFFAB</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6c2ed1f7-db8a-4988-8a86-b69323b88455">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274189" xl:show="new">C4274189</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0f0de160-e785-4ed9-b8d8-7ebd132fb568">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328786" xl:show="new">328786</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3a693a80-4085-419e-9208-ed448dfc6370">Mid L TZp</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9e1ae56e-2433-4a40-a146-728fde8b6d36">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128604" xl:show="new">C128604</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ddd47923-60ed-4d82-b872-299968d6a8a9">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c276fd60-8ef5-4640-9c17-01ff43573837">
                        <link xl:href="http://snomed.info/id/716939003" xl:show="new">716939003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fe1b492e-93c6-49a3-a23e-e62d8bc4ab4e">Left posterolateral apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e8233411-0520-42df-b3f4-806887325758">
                        <link xl:href="http://snomed.info/id/716939003" xl:show="new">R-FFFDD</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_568003e5-51e6-4be9-b48e-8140adaef755">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274168" xl:show="new">C4274168</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f1f61ff3-7a08-4f59-ab2b-c5c8d3a73533">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328752" xl:show="new">328752</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_50bec00b-8ef4-469a-86e4-72895cccda4a">Apex L PZpl</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7b2461c4-ee61-43d4-bce2-6a4c4861f92e">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128576" xl:show="new">C128576</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e35b1454-5fc7-4faf-8e76-9d75710a92b2">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1ad51622-018a-46d6-8669-9bd5e723ffea">
                        <link xl:href="http://snomed.info/id/716907005" xl:show="new">716907005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_776e4dc6-f73d-404d-a432-4c67fb2be688">Left posterolateral basal peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f9efba95-fb19-4c2d-9551-0552c2062af6">
                        <link xl:href="http://snomed.info/id/716907005" xl:show="new">R-FFFC2</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a981e445-6dda-4a99-adbe-7adb34626dab">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274197" xl:show="new">C4274197</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fb0e4dc4-5000-4232-aa3b-2cb2b4902a8b">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328759" xl:show="new">328759</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dce20453-3e8b-4a49-b4ec-e24fd54579fe">Base L PZpl</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b288097a-5c87-4635-883a-f490f9f86295">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128591" xl:show="new">C128591</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_04a0005d-3602-4013-94bc-3f236828f362">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_edcf1401-008b-4593-9c5b-15b2f49ff6e6">
                        <link xl:href="http://snomed.info/id/716922000" xl:show="new">716922000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6ee0a884-b038-4396-a535-b9670f6e1ccd">Left posterolateral middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b4e31789-7f40-4e7d-99dc-5d693987d11b">
                        <link xl:href="http://snomed.info/id/716922000" xl:show="new">R-FFFE9</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8033a631-940a-4889-bc79-24741e743949">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274180" xl:show="new">C4274180</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_07725a5c-4dc3-44b3-bd54-0d2288674ff1">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328791" xl:show="new">328791</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_70144af0-9daa-4485-9292-2abed5dd5634">Mid L PZpl</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ab95135e-fad6-4e9d-af1a-9f1bc61fd3e4">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128601" xl:show="new">C128601</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_db890449-390a-477b-899b-abcdb96c712a">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_30ad405e-00e7-4cb6-926f-2f056348ef7d">
                        <link xl:href="http://snomed.info/id/716941002" xl:show="new">716941002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f0e79003-b1ed-4694-9bf2-6fa8be78a058">Left posteromedial apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6e7b12fd-8e40-4233-aff5-7b8cb05a5ab7">
                        <link xl:href="http://snomed.info/id/716941002" xl:show="new">R0-0000B</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b8b0380a-bfd3-49bf-93be-b026bf24ec6a">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274166" xl:show="new">C4274166</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4d5fd7aa-b43c-4125-ad3b-cdb0e1dd2c53">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328792" xl:show="new">328792</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_97e70f65-d035-4c8e-8470-9fd227576553">Apex L PZpm</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7934379b-81f1-44e2-b936-29a86c0cdcbe">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128577" xl:show="new">C128577</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_842c6f19-ee02-48c9-ba77-ba9788a1741f">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ab12913c-52fa-4d6e-953b-b19ac88f7802">
                        <link xl:href="http://snomed.info/id/716924004" xl:show="new">716924004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_125ab80a-5a0f-4864-a4f4-8d495ba5f6fc">Left posteromedial middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a6226bc5-31b9-4b77-8c82-230e8d8e1319">
                        <link xl:href="http://snomed.info/id/716924004" xl:show="new">R-FFFB5</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_18d64374-8da9-4cde-8ddd-84f66cbdcf97">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274183" xl:show="new">C4274183</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cff2a879-e19a-4f1e-b38d-629e52f69686">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328777" xl:show="new">328777</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ba7e2b3-5930-4ad7-9f07-bf542d85cc78">Mid L PZpm</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_473335d1-26f8-4ff7-9699-d844f33ed99c">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128602" xl:show="new">C128602</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9c982e1d-c9a3-4bc0-8b0d-d9e227b0ddc2">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b4e6e017-bcfa-446d-90be-5289b11ace06">
                        <link xl:href="http://snomed.info/id/42320003" xl:show="new">42320003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_004b0f1a-59e8-49a9-b14e-cbeb42e425ce">Left seminal vesicle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7a787a0b-6a8a-4888-af85-a8e0504fc086">
                        <link xl:href="http://snomed.info/id/42320003" xl:show="new">T-93020</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9ea086ed-ae7c-4584-acac-21a2f2abda38">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0227980" xl:show="new">C0227980</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6a7d2c8d-3654-400b-8c75-26341b7f8ab1">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=19388" xl:show="new">19388</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f64839e0-72c8-4abb-b6ec-6b50359d3650">L SV</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e9bb747c-6acf-43ae-9764-37f1f6343d68">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128598" xl:show="new">C128598</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e05c356a-3362-4676-91bf-99e59645b9eb">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_95311d82-2754-45b6-a763-bd6398fb3526">
                        <link xl:href="http://snomed.info/id/717027004" xl:show="new">717027004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_78411cb5-b087-4923-8d1c-4c1fb3442086">Male external urethral sphincter</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d330a0c5-6522-4a1f-8283-dc4fa3690d0b">
                        <link xl:href="http://snomed.info/id/717027004" xl:show="new">R-FFFD9</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cdba057a-fa39-427d-8158-06c4e80ad9c8">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0815353" xl:show="new">C0815353</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cf1a1ceb-3ee0-4620-b05b-552d2f24a38c">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=19733" xl:show="new">19733</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_55c6e4ef-1b4b-48cf-99b2-bd66c6c971d6">US</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_af9ae1e2-27c5-44df-8c61-fa21ff1546b5">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128612" xl:show="new">C128612</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5d4f40ca-b8d8-407d-b64c-2dc58c51295e">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_340b4b24-a843-47c8-9308-88e28b24effa">
                        <link xl:href="http://snomed.info/id/716936005" xl:show="new">716936005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6ced770b-cb8e-4e11-b72d-7bf605b4abdc">Right anterior apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4e3651fd-dd81-4f1a-8380-50d245d794e6">
                        <link xl:href="http://snomed.info/id/716936005" xl:show="new">R0-00003</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e17633c5-a41f-4cf9-af72-ad725985799b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274125" xl:show="new">C4274125</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_98e16945-f946-4f67-aaef-d5b0e7b32900">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328779" xl:show="new">328779</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_afeb5e1b-8c69-4ee3-8784-326fab5d8548">Apex R PZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5aa9a1dd-978f-4073-ac97-a160ab9c1366">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128581" xl:show="new">C128581</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6cff8375-e882-45b4-a11a-cc502170eabd">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0834ff0d-ce16-46bf-aaf3-d75879d7966a">
                        <link xl:href="http://snomed.info/id/716930004" xl:show="new">716930004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0e42b39a-07b6-431e-bd5f-8f672c0c93f7">Right anterior apical transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fe6e77d9-0c92-4a8f-aff4-6f53d029da16">
                        <link xl:href="http://snomed.info/id/716930004" xl:show="new">R0-00006</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b0e42013-209d-41ed-a771-7a5eadac7fc7">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274131" xl:show="new">C4274131</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_78ea1c3a-0929-4604-bde4-7445307f6606">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328761" xl:show="new">328761</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2b913787-1be8-471c-8352-b07ad2389b06">Apex R TZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a3b1a2e1-d0cd-48d8-a581-859e95bec4bc">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128584" xl:show="new">C128584</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3bf8d1c8-0fc3-449e-8d18-cf32712385e3">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1b59c8ff-87e7-4080-9b87-d9d588c3fba4">
                        <link xl:href="http://snomed.info/id/716904003" xl:show="new">716904003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4433de3d-2f4c-4c04-a9a4-5830af6f109e">Right anterior basal peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_03baeb44-301d-4e9e-bff4-e6ce1212faca">
                        <link xl:href="http://snomed.info/id/716904003" xl:show="new">R-FFFE2</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1a93c5d2-cf37-456f-9c64-11d02b9e760d">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274200" xl:show="new">C4274200</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6e76ca20-8953-4830-850b-55b0488d0414">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328798" xl:show="new">328798</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c59f31dc-804a-470a-baeb-8715711e68d4">Base R PZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_20ca59f5-b134-4d11-9adb-facaa7d77973">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128594" xl:show="new">C128594</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_af01904c-963e-4c50-a89c-21076e57dda3">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_af400224-ef37-4989-a991-131f7df78103">
                        <link xl:href="http://snomed.info/id/716896009" xl:show="new">716896009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_45c68aac-51f7-4737-b9f6-9942d4efb80c">Right anterior basal transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_72a6e3f3-d304-4bb9-b020-23636a3d950a">
                        <link xl:href="http://snomed.info/id/716896009" xl:show="new">R0-00000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8437516c-fd98-4c27-be82-d6726f4ca968">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273547" xl:show="new">C4273547</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_74726f69-6b4c-48df-97cf-5f26d1552fe0">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328793" xl:show="new">328793</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_474eef86-1f8d-464e-889b-5db776447edd">Base R TZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a6261a73-eed1-4fa5-96bc-2e403daa6a5e">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128596" xl:show="new">C128596</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d31e87c8-9b61-4fae-9bb6-5bbeccb76bd3">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c4b612a1-224f-46e2-8ba3-bc44087bd25b">
                        <link xl:href="http://snomed.info/id/716919002" xl:show="new">716919002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8a49cfc1-9dba-4a26-9df1-4990ba66cbb4">Right anterior middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_34e474b5-096c-49be-8561-3916f20e21e1">
                        <link xl:href="http://snomed.info/id/716919002" xl:show="new">R-FFFCD</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e5663509-aaa9-4485-9b27-e3da6f82b9d2">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274141" xl:show="new">C4274141</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2e753e39-4dfc-4e78-aaf3-fa545c97b758">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328796" xl:show="new">328796</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a3152598-3814-4377-bf73-d574d6c163bc">Mid R PZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ffcab99-a524-4598-ae94-6d9f0cd3a939">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128606" xl:show="new">C128606</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4022856f-5b05-4313-895c-0ebfc19dc400">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_231ad89d-4584-4c3e-b65e-2da43262721f">
                        <link xl:href="http://snomed.info/id/716913001" xl:show="new">716913001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a1b03b89-044a-49cd-be4b-a658ba0cc24c">Right anterior middle transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c64a93e2-ccf4-40cf-af33-9c1ad0c56848">
                        <link xl:href="http://snomed.info/id/716913001" xl:show="new">R-FFFF4</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f53dedf4-08ea-41f6-8706-145ccc64ac85">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274147" xl:show="new">C4274147</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_31018fe5-e424-478e-8240-8fa8d9cba3a1">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328800" xl:show="new">328800</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6ee8efb4-c526-432d-a8fe-05d2a4ef8575">Mid R TZa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_272d6450-5415-4735-9ae4-4191c0746b0e">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128609" xl:show="new">C128609</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5790c40c-547c-4962-8243-ebb9ac3b4a7b">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dbe64166-a225-4930-8bc9-c931a2006200">
                        <link xl:href="http://snomed.info/id/716926002" xl:show="new">716926002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_93a9b454-5593-4d69-9f7e-a0893fe4510e">Right apical anterior fibromuscular stroma of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9e80a7aa-790f-40d9-987b-f77b75a4c682">
                        <link xl:href="http://snomed.info/id/716926002" xl:show="new">R-FFFFD</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cf6bec9f-52f9-4c4c-8754-48b050dc4cd5">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273870" xl:show="new">C4273870</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_594b8b82-082e-4655-b94e-47bfcae318e9">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328801" xl:show="new">328801</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a8ed9a77-130e-46bf-aaa3-218ccb65e38f">Apex R AS</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f70e391c-3440-4181-86b1-569a8ad7dd3b">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128580" xl:show="new">C128580</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4b80eaf5-1d67-4459-a51a-0000ea2c052e">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_24e62b58-7c95-4dbc-ad3f-ddd388db7980">
                        <link xl:href="http://snomed.info/id/716892006" xl:show="new">716892006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a481990e-1e18-47a1-ad7b-86f3eccb291f">Right basal anterior fibromuscular stroma of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_15edf1b8-96f1-4e99-b093-b06aaef62601">
                        <link xl:href="http://snomed.info/id/716892006" xl:show="new">R-FFFF2</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_77491607-8b55-467f-ac75-41ac8a5fd079">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273849" xl:show="new">C4273849</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_952a03c3-e152-4854-981d-e899ddb2d55d">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328778" xl:show="new">328778</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cfad04a1-c30f-48f5-a6ff-e4675d45a14a">Base R AS</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_00a6fd66-f659-4c7e-8c81-fee770003c12">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128592" xl:show="new">C128592</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1f03ec83-c0cb-4aad-9499-19fd00025865">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4af3458f-191b-4fa3-ae9e-6ba226ff9f7e">
                        <link xl:href="http://snomed.info/id/716909008" xl:show="new">716909008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ff0df354-0bcc-4ca4-8291-1ff8084e0017">Right middle anterior fibromuscular stroma of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_820bc3bf-3d7f-42be-b712-59c3bc22746b">
                        <link xl:href="http://snomed.info/id/716909008" xl:show="new">R0-00004</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7b71df42-9b7e-4725-bc39-d22eee917ef7">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273544" xl:show="new">C4273544</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e7c86784-a618-4c90-b52c-3e09affb9cb0">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328783" xl:show="new">328783</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_845d2d3c-a156-4da7-86b7-0c558349a35c">Mid R AS</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_81e99a83-5fc3-47b4-a77b-7e627ba095b1">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128605" xl:show="new">C128605</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8b6af634-aea6-44c6-9edc-bc29e9f07e2a">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_47acc99c-c45f-484a-9201-1f9f696cee85">
                        <link xl:href="http://snomed.info/id/716932007" xl:show="new">716932007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_dade8bd3-18fc-4242-ab5c-24f53c07de26">Right posterior apical transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dc722429-74f8-4b8d-b00d-5a3e117580c3">
                        <link xl:href="http://snomed.info/id/716932007" xl:show="new">R-FFFF3</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_94d59615-05b4-4073-9856-b13e04cb40a3">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274099" xl:show="new">C4274099</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_11eb79ce-7002-4dde-b541-e62daf239d2c">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328763" xl:show="new">328763</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_48b056f9-2683-40b7-89fc-3de1683f29d5">Apex R TZp</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_88371884-03b5-415b-a483-70811e54e1fc">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128585" xl:show="new">C128585</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_62ef4007-a063-4298-a80f-34fda309888f">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f1475915-7be4-47f2-aaa8-f58f08721cee">
                        <link xl:href="http://snomed.info/id/716898005" xl:show="new">716898005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_68e29e4c-c323-48df-ae20-69a900bf37c5">Right posterior basal transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0c1bb773-ca37-4e0b-a223-c47f650e0250">
                        <link xl:href="http://snomed.info/id/716898005" xl:show="new">R-FFFB1</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7374a518-5fd2-45d2-bbae-ea98551cb683">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274205" xl:show="new">C4274205</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_95a30fbf-f376-43d6-bb7b-20944901b324">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328799" xl:show="new">328799</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6f5bd5a6-67ad-4d97-8fe9-0af72263188e">Base R TZp</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ec486d7e-7f25-48f4-b5ca-bb1f9198533c">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128597" xl:show="new">C128597</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_475672dd-23b2-4a4a-b798-f799b2422f10">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d849dab1-1ce9-4489-9876-35345287bf09">
                        <link xl:href="http://snomed.info/id/716915008" xl:show="new">716915008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_52b2beb9-0950-46f5-bf6b-6b10e68cbf6b">Right posterior middle transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cd2b5f7b-a279-481d-a87d-006dafe0ee5f">
                        <link xl:href="http://snomed.info/id/716915008" xl:show="new">R-FFFC9</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c43a39aa-fa1e-4783-acdc-0c5541f5f9b6">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273542" xl:show="new">C4273542</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8e6abe63-74fc-4d7a-9a3d-7f61429c34b4">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328787" xl:show="new">328787</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_806bdeb7-a429-4211-a9f0-1b08ff8c61a3">Mid R TZp</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1db8e07c-4474-4302-9efc-d16ffee918d6">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128610" xl:show="new">C128610</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_845f6783-fd9b-491c-b7a2-b75dc4d90aea">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4be482ed-a45f-47c5-8444-b32192d749ea">
                        <link xl:href="http://snomed.info/id/716938006" xl:show="new">716938006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a9e77e13-ada8-48a1-b293-125807973ac1">Right posterolateral apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_52f26ccb-0486-4822-aad7-0504c8893d7e">
                        <link xl:href="http://snomed.info/id/716938006" xl:show="new">R-FFFC0</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f72ea3f5-0fb1-45a9-8765-e1e2c942d300">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273861" xl:show="new">C4273861</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b609d658-b729-4010-8698-4076003dbabe">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328782" xl:show="new">328782</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_377bb987-d551-4598-9982-587fe89d3c19">Apex R PZpl</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf5ae7c7-976e-4590-bf85-f102d00ddc95">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128582" xl:show="new">C128582</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9d0c14f0-f80a-4fdc-a780-a6b77d5673e5">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0a317e45-7aeb-4dab-84e8-d3705b84537e">
                        <link xl:href="http://snomed.info/id/716906001" xl:show="new">716906001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5fec66e4-8c3c-4f72-93ad-f6a157885ac5">Right posterolateral basal peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fc1e2aac-7e37-4edb-bb88-e493330102e0">
                        <link xl:href="http://snomed.info/id/716906001" xl:show="new">R0-0001E</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_08bb8cd6-aa1b-4b60-b523-207226a362ac">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274198" xl:show="new">C4274198</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bed13ccc-7502-4f54-92a6-ea7dc29f31f9">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328797" xl:show="new">328797</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1586e9bb-bc3b-4272-bb34-515af9f57614">Base R PZpl</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ac8459b8-5f81-4c56-9bbf-064d2606596f">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128595" xl:show="new">C128595</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9dc8d8af-0263-419d-ac97-10603f893725">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c89bcb7f-ac3a-45b5-a94f-2ae44571736d">
                        <link xl:href="http://snomed.info/id/716921007" xl:show="new">716921007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a8c54278-d42f-46b4-95a9-6cc527900c9f">Right posterolateral middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c2beb516-15f2-43c3-a712-3adfaff54ccb">
                        <link xl:href="http://snomed.info/id/716921007" xl:show="new">R0-0000C</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bd0dda87-d47b-4d38-9c8b-efe8d124cb34">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274184" xl:show="new">C4274184</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e5f5b810-512a-4482-b2f2-5e2b64581c7e">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328771" xl:show="new">328771</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a56aaf0d-2d07-4832-b866-ea599786dfb4">Mid R PZpl</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_36cfad18-f13d-4f10-b036-2209d920b06f">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128607" xl:show="new">C128607</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4c19b935-3d7b-441e-92a8-9dbf822f22ca">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_44d141b7-e51b-4b33-8aaf-312780966728">
                        <link xl:href="http://snomed.info/id/716940001" xl:show="new">716940001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_693d262d-fac3-4fc4-a9bc-b03646d0f11d">Right posteromedial apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d3e0ff97-7bae-4d76-bf20-6767775bffa5">
                        <link xl:href="http://snomed.info/id/716940001" xl:show="new">R-FFFEA</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ace1f69c-7a01-4c09-85f6-5eb53cc7ae9b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274167" xl:show="new">C4274167</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6a1ebff4-9026-4204-9704-32c698ce5577">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328764" xl:show="new">328764</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1003067e-731e-4e5a-80d7-e8b281730d04">Apex R PZpm</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_91c3aaa6-7831-43f6-8558-574391535704">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128583" xl:show="new">C128583</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c1e989b4-7a41-4ce2-a825-82ab816ae3ab">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6e97b05e-c8b5-4396-ac6b-900ee236fe38">
                        <link xl:href="http://snomed.info/id/716923005" xl:show="new">716923005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c92363ce-eae9-4fe6-970f-88ea11949b93">Right posteromedial middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1d6fe2db-7ebf-4ee2-8165-330c2229d011">
                        <link xl:href="http://snomed.info/id/716923005" xl:show="new">R-FFFD4</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9e2ee2aa-1ef0-4351-b52a-2e4e9de89e2a">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274181" xl:show="new">C4274181</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d648c5c4-7642-427b-b5c8-9961853d2424">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328766" xl:show="new">328766</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_99f1bed0-99e0-48e2-87ba-3aed2bfef3ed">Mid R PZpm</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1edcb98b-4420-4790-b910-974078a58266">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128608" xl:show="new">C128608</link>
                     </para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3dd5c836-4a75-4350-aa45-5561467c66eb">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_389b66cf-3401-470a-b825-024bd1f4c148">
                        <link xl:href="http://snomed.info/id/74308000" xl:show="new">74308000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1c7631eb-ce16-4869-a749-95e2661fed0a">Right seminal vesicle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f4507d4c-2784-44e4-bfbb-effbda5034a8">
                        <link xl:href="http://snomed.info/id/74308000" xl:show="new">T-93010</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7ffe5acb-f78d-41bc-9fba-b6131692dc5f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0227979" xl:show="new">C0227979</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_66431254-75ef-45a1-b922-440751629b74">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=19387" xl:show="new">19387</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_792a0224-a13f-4582-b4e6-c3e6c33f49e7">R SV</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b1cc4644-13dc-4b22-9452-8809451bb6bc">
                        <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C128611" xl:show="new">C128611</link>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
        
        <section label="CID 6302" status="3" xml:id="sect_CID_6302">
         <title>Prostate Sector Anatomy from European Concensus 16 Sector (Minimal) Model</title>
         <note>
            <para xml:id="para_b66dcc71-06ea-40b4-b979-262bba58238a">From <xref linkend="biblio_ProstateEuConcensus"/>.</para>
         </note>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_2a55bc8c-4534-4458-9f51-5b17b4086e68">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6302.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_6302.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_6302.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1140.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_58585bc9-127c-417a-9e69-46706e58dae9">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_9bb626a4-867b-4042-a5be-46f4f9f169e7">
                     <emphasis role="bold">20161106</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_5ba23799-dda2-4a51-a36d-0910b3d624d7">
                     <emphasis role="bold">1.2.840.10008.6.1.1140</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 6302" rules="all" xml:id="table_CID_6302">
            <caption>Prostate Sector Anatomy from European Concensus 16 Sector (Minimal) Model</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_382c6d1e-1bc5-460f-b3e5-44c2b80de770">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_34b6dc5f-64f4-425e-8bdf-1d5ed0165a21">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9f7d19e4-70e6-4dc5-b5c4-57dd3f6495dc">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_008f7f66-6adb-46b9-97ad-a54a9bb91d55">
                        <emphasis role="bold">SNOMED-RT ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_961eedb2-5cb0-44b6-b3e9-8306ef657f27">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c0b8fc08-2d60-4756-9816-b0c3b312f87e">
                        <emphasis role="bold">FMA ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d3125c09-87d3-4816-bce6-ff4a3bb419a7">
                        <emphasis role="bold">16 Sector Code</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_edda8ca3-0c85-4036-8039-382cd4fd4c94">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5d4a3c55-69c3-456e-82da-6ba427e7e113">
                        <link xl:href="http://snomed.info/id/716901006" xl:show="new">716901006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ff394b0a-79eb-4b22-9b1e-5f880d7e6e6e">Central zone of left half prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f6075218-0c37-4aec-8354-8236d157f9b2">
                        <link xl:href="http://snomed.info/id/716901006" xl:show="new">R-FFFFC</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_76c2d4d1-d984-49e4-ad4e-a88360dcfa0f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273550" xl:show="new">C4273550</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_39cd80f0-b6df-4226-8f00-1de72a7f34d8">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=302475" xl:show="new">302475</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_21dfdbde-bf2b-4e88-95da-b87096266732">6p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_25165890-2c45-492e-929a-f8e8c39fc80b">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0860e1f9-0722-4004-83c7-07cc3a1bdc1c">
                        <link xl:href="http://snomed.info/id/716900007" xl:show="new">716900007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3e356fc7-01f8-4794-bc9c-39ff463fac8d">Central zone of right half prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_963ca9ff-f860-4e2a-8f7d-5979b86e9f43">
                        <link xl:href="http://snomed.info/id/716900007" xl:show="new">R-FFFD0</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fbc3654e-8937-43d4-b387-54384f995dd7">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274157" xl:show="new">C4274157</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f423f25e-1837-4620-87cc-8d97a3350618">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=302473" xl:show="new">302473</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4a0756c3-f6fe-4072-80e7-b55394581357">1p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_02348c54-2789-4108-8e5c-fb1c6ae4f3f0">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b0f1d5f7-df01-4159-bbc5-7e8951f6d5cf">
                        <link xl:href="http://snomed.info/id/716935009" xl:show="new">716935009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a3374ba6-1f38-4bbb-a057-0dd20c1aabb3">Left apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_49aa3147-7e6d-4e45-9287-4677834d3d5d">
                        <link xl:href="http://snomed.info/id/716935009" xl:show="new">R-FFFD3</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f5c47b4e-7f8c-484f-bef7-0444da3d2845">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274171" xl:show="new">C4274171</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_21ecf2c2-6214-4dc9-a2bb-d70a0aa86d40">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328790" xl:show="new">328790</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c454ac3f-2b3a-4cbd-8d7e-de19ef877819">10p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c16966b6-a04e-4626-984b-c62c97648a23">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_618f196b-3d9c-4726-8172-e16190d81be0">
                        <link xl:href="http://snomed.info/id/716929009" xl:show="new">716929009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c67d6fdb-b485-4c71-a3cf-ce90d32364bf">Left apical transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b5c5e12b-357a-4ad6-9a0c-3c20bf0b1a22">
                        <link xl:href="http://snomed.info/id/716929009" xl:show="new">R-FFFA9</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_10c27a39-3238-4779-8b66-bb29e340b97f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274176" xl:show="new">C4274176</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e09788fc-3e35-4c37-9099-f27da3548bdd">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328769" xl:show="new">328769</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d9dd49a5-7b34-4775-8927-74eb10f23abe">6a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_48efcc4b-cfe3-499b-a571-31fd42a98388">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e1d4383d-de62-47a6-8da0-b3defb3839f3">
                        <link xl:href="http://snomed.info/id/716895008" xl:show="new">716895008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5b88b672-1cfa-4096-83bf-a63646909387">Left basal part transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ff9d7079-4376-4507-a26e-dd492158809a">
                        <link xl:href="http://snomed.info/id/716895008" xl:show="new">R0-00020</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7aa0bc58-360f-451f-a8bb-fa35e4e75712">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274160" xl:show="new">C4274160</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3f6ecbc0-4a8d-418f-b41b-9154c9ef8d2e">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328755" xl:show="new">328755</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_caa32932-63e3-4d1e-8e1a-ca9cc9ac8223">4a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2b7c7681-5053-4111-8fc9-12f98aa60c84">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bc8fd531-696f-49eb-92b2-75dce3f4fbfb">
                        <link xl:href="http://snomed.info/id/716903009" xl:show="new">716903009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e0653716-cee1-4c1c-b3c0-7c0aa3dcbfbd">Left basal peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5548c1b2-b782-4155-9bab-cd6d2fcf0792">
                        <link xl:href="http://snomed.info/id/716903009" xl:show="new">R-FFFC4</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a97b2cfd-a633-4592-bbce-6a9d3bbf716a">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274120" xl:show="new">C4274120</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f870a853-5b5b-4943-962f-db83b4af832d">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328765" xl:show="new">328765</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e7d03725-ec32-4494-b86c-18f07489c898">7p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7c9455ff-f514-45da-b024-14d8bcbbdeef">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_544de807-deb0-4ced-bdab-a246bd600d52">
                        <link xl:href="http://snomed.info/id/716918005" xl:show="new">716918005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f3eeb543-501c-4155-a68b-350b88ee1c8a">Left lateral middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_117841e9-9758-44b1-9297-178efcf2fdac">
                        <link xl:href="http://snomed.info/id/716918005" xl:show="new">R-FFFE6</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e62e3e6b-b909-4720-a9eb-89be0eda6d6a">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274142" xl:show="new">C4274142</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5cbecb5d-c936-4dde-b37f-6b07897a63cf">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328767" xl:show="new">328767</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fbcf4004-1326-469c-98b8-a160277f4002">9p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9a626636-f3ff-4685-ad5c-badb297a6989">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4373e6be-8c77-4c9c-b30a-4b1621235204">
                        <link xl:href="http://snomed.info/id/716912006" xl:show="new">716912006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_2bc2d86c-f1f5-4b48-8061-81a98a4b51aa">Left middle transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_54554abd-232b-4b80-846f-abef42530d85">
                        <link xl:href="http://snomed.info/id/716912006" xl:show="new">R-FFFD5</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b204a414-5c1f-4470-807a-72927aa3c04f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274192" xl:show="new">C4274192</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d7881116-d3f6-403c-b387-f02da1bcd280">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328762" xl:show="new">328762</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_27bdeab9-0e8d-4c9e-b5d1-9758b01c0172">5a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c5314aff-b52b-4cd9-b13e-09226f62a041">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_36724231-d290-40e6-93d1-6a8955d1b5bd">
                        <link xl:href="http://snomed.info/id/716924004" xl:show="new">716924004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6bc63127-7f68-4ad8-8196-1d85fbf4441d">Left posteromedial middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9027e9e3-e86c-4e75-b229-2f256e5935e8">
                        <link xl:href="http://snomed.info/id/716924004" xl:show="new">R-FFFB5</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7de4e394-e339-40de-8db0-776d571b9b17">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274183" xl:show="new">C4274183</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_08e006a9-c97a-444d-8ef5-3f8797a1a714">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328777" xl:show="new">328777</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_06ce0d4a-201d-49d2-a813-55bdbf4fa7ca">8p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_92ba6940-4943-426d-8ed5-a077d2a314de">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dbfb125f-beb1-41b1-9ecc-02056ed0c758">
                        <link xl:href="http://snomed.info/id/42320003" xl:show="new">42320003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d16f0b8c-ad7d-4cd3-b9eb-94aa1104d38e">Left seminal vesicle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_84976890-429a-46b5-b414-0f9c2d8640fb">
                        <link xl:href="http://snomed.info/id/42320003" xl:show="new">T-93020</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c8a2381a-5f58-42b2-9af9-09d7549fc083">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0227980" xl:show="new">C0227980</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0c8f0372-c5ef-412c-a288-3d9f7dc4667f">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=19388" xl:show="new">19388</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a3b57c8b-20fb-4cac-9f46-35d5fec79001">L SV</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c3b5315a-7946-441c-865f-f1461ad64b16">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c06d64ea-340b-4932-af1b-d155c4da4356">
                        <link xl:href="http://snomed.info/id/717027004" xl:show="new">717027004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4c98729c-57b9-4bb2-902c-a7fb2e5398a3">Male external urethral sphincter</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d80f1db5-765a-4119-a62a-a1f9d5fd593a">
                        <link xl:href="http://snomed.info/id/717027004" xl:show="new">R-FFFD9</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6967a74a-dc20-4f25-9a21-7087c4e7d1cb">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0815353" xl:show="new">C0815353</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9f935445-66c8-4182-934e-a3bf84287f09">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=19733" xl:show="new">19733</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7af7ee63-6b5a-4f0f-9f66-3c8be4704e26">US</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_44dfb7ec-880f-43c3-a8d3-0e501ff312d0">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_124d4094-e1b2-4a8c-b000-44d7fa560149">
                        <link xl:href="http://snomed.info/id/716934008" xl:show="new">716934008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_06801d9d-afd1-431d-aece-f7b558281f9f">Right apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5531d0b6-6163-4a9f-9ee5-baa813c370d8">
                        <link xl:href="http://snomed.info/id/716934008" xl:show="new">R-FFFB3</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_13059bba-37ca-4838-a495-5573dc60155b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274128" xl:show="new">C4274128</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a11e7e2f-a9c8-49d7-b266-794bacad7095">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328794" xl:show="new">328794</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_82d36651-b03e-432f-a731-c45f9bda05cf">5p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5589f626-d43e-46d5-9074-d31bfc685f2a">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f02719ac-a23a-4451-9df4-706d80b32d3e">
                        <link xl:href="http://snomed.info/id/716928001" xl:show="new">716928001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_255a1965-59e0-45e5-aae4-9679949b7913">Right apical transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ecbf6fc-da89-4a2d-b368-fe3e7e10345f">
                        <link xl:href="http://snomed.info/id/716928001" xl:show="new">R-FFFC1</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ea32dab5-8928-4d7a-95f7-20a2e2abda26">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273855" xl:show="new">C4273855</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1372c238-775c-49fa-bf14-eb2349b77163">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328773" xl:show="new">328773</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b3d696e7-5168-4b3c-8e50-a2628e800973">3a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b4e9cc85-e2cb-4d81-9645-28745a97e8ba">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fd00a336-4253-41ca-9032-dcf621a2bdc7">
                        <link xl:href="http://snomed.info/id/716902004" xl:show="new">716902004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c45324f6-fe3d-4c6d-bc00-802a2a353700">Right basal peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_88df2958-f928-49e0-ab2f-fbd9adf52771">
                        <link xl:href="http://snomed.info/id/716902004" xl:show="new">R0-00018</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_822d8fdd-c3bf-4a93-b335-e635b3204fba">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274155" xl:show="new">C4274155</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b1b39289-1d19-46e0-ab69-77369e473338">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328802" xl:show="new">328802</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9e3adade-abce-446d-9053-01b42216dd3f">2p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3c41f378-1c25-40f0-8365-4f44fbdd3190">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d73424cc-03dd-4aca-bfe4-bbb3ae9b670c">
                        <link xl:href="http://snomed.info/id/716894007" xl:show="new">716894007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_efec83f3-789b-4765-bed4-e2994b501145">Right basal transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d842f8cb-97db-4625-9ce8-637b524018a9">
                        <link xl:href="http://snomed.info/id/716894007" xl:show="new">R-FFFBE</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2cb08630-95c0-4ce0-af2c-999d0f2e4c6c">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274164" xl:show="new">C4274164</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_34bad9bb-6b54-4397-aca4-313f39911c7b">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328780" xl:show="new">328780</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c83afc81-7320-494e-8552-4ca6a9e6e87a">1a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_613a92b3-7cc3-4daa-aba6-81b9c747379f">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f75e6275-13e2-4213-a74e-777e8d293148">
                        <link xl:href="http://snomed.info/id/716917000" xl:show="new">716917000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b15d41c1-93dc-4225-9ba1-0fc8baa848d7">Right lateral middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_938d971d-1687-4245-8d37-573914f652b8">
                        <link xl:href="http://snomed.info/id/716917000" xl:show="new">R0-0000F</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c90bff2c-e943-4292-adcd-479a7b8f3ed8">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274143" xl:show="new">C4274143</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5a089a6b-b0f5-482b-8894-62aaa01b792b">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328803" xl:show="new">328803</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e2860211-8d79-4c2b-951c-54234417fdc7">4p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b1bfa23c-a1df-438a-b26f-a50031b1e81b">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5401c08a-b9bf-47a7-b5cf-ee08d50c9652">
                        <link xl:href="http://snomed.info/id/716911004" xl:show="new">716911004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_62d8338f-e469-404d-b1b6-5a5eb40ee42f">Right middle transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a9654c24-1290-4c23-8094-a0b25d7cdadf">
                        <link xl:href="http://snomed.info/id/716911004" xl:show="new">R-FFFB6</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ade0a80e-8c75-45a7-9489-9a0e04684d50">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273545" xl:show="new">C4273545</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_19450ac3-7b81-44a6-97dc-d79bd7621afc">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328757" xl:show="new">328757</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_39f481de-56ba-4292-9264-3d2371253f55">2a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ec9cc5b2-abee-4cba-9d8e-d7385134f84e">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e552a023-bf6a-4f3a-9260-9aba2b49e43b">
                        <link xl:href="http://snomed.info/id/716923005" xl:show="new">716923005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6e19fde5-c351-4e4b-87cb-44302824e6ac">Right posteromedial middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0442cba9-29af-4231-b3f4-5ac13fd578f8">
                        <link xl:href="http://snomed.info/id/716923005" xl:show="new">R-FFFD4</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_40bb7117-83be-4226-b052-f9e7114de30a">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274181" xl:show="new">C4274181</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9461e2ff-2c22-4733-bbca-0c2c4d31cbdc">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328766" xl:show="new">328766</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4037e53b-7728-494e-9f06-f9330393535e">3p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fd363a6a-d338-4040-b6fc-347d5a66cb8f">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_417469df-b517-4288-98b4-7703161e9872">
                        <link xl:href="http://snomed.info/id/74308000" xl:show="new">74308000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d76416a1-a49b-4173-9140-cce73de4ae1b">Right seminal vesicle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_24244254-22de-4cf1-b8b3-35199eefc17e">
                        <link xl:href="http://snomed.info/id/74308000" xl:show="new">T-93010</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_612b865f-f157-4eff-aa62-0b2974766495">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0227979" xl:show="new">C0227979</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e8707cc6-298f-44a3-b187-f15ad27f3d04">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=19387" xl:show="new">19387</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0e1059b8-4a0b-4ce9-818e-682ba11e4f00">R SV</para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
        
        <section label="CID 6303" status="3" xml:id="sect_CID_6303">
         <title>Prostate Sector Anatomy from European Concensus 27 Sector (Optimal) Model</title>
         <note>
            <para xml:id="para_d92932d1-50b6-4831-8e3a-7c40ae397e82">From <xref linkend="biblio_ProstateEuConcensus"/>.</para>
         </note>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_5509e17c-a644-4346-a7c0-86623f316fbf">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6303.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_6303.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_6303.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1141.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_dfb750cb-c49b-4d1b-8794-536fb8cf1519">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_d346962e-be0a-4dd0-976f-f1b02a1e324e">
                     <emphasis role="bold">20161106</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_00949069-1ee1-4aa1-af7a-8ac46b54a65e">
                     <emphasis role="bold">1.2.840.10008.6.1.1141</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 6303" rules="all" xml:id="table_CID_6303">
            <caption>Prostate Sector Anatomy from European Concensus 27 Sector (Optimal) Model</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3699460e-ad18-4d33-8eb0-e5f353853ee2">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8a4244a7-7cc0-4bb1-932f-ff90e2a764a7">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_76317173-d21b-4b88-85bb-d848d7fc13df">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f40fc911-ba7b-4372-8d64-bcd9f40351c9">
                        <emphasis role="bold">SNOMED-RT ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b924bfdf-3492-41c5-bcee-e8dae4b0a809">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7509651f-7bd4-44c6-878a-e341504a8a81">
                        <emphasis role="bold">FMA ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_34c0e69b-d018-4e49-9288-b53b1a1954ae">
                        <emphasis role="bold">27 Sector Code</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a31ced0c-1d59-4013-8ae5-4037b01fcba9">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e8f0f7b5-3e12-451b-a35f-fb41fb0bf9d7">
                        <link xl:href="http://snomed.info/id/716925003" xl:show="new">716925003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f257bb14-e860-4031-9517-2defbe5bc288">Apical anterior fibromuscular stroma of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2fc5962b-d3e8-4f14-b14a-74507ffa75ca">
                        <link xl:href="http://snomed.info/id/716925003" xl:show="new">R0-0001B</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1338349d-e1bd-44ab-9995-004b9d72ffa5">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274179" xl:show="new">C4274179</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0b1f0a4e-8a67-46c4-807a-a0b2f2941671">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=302546" xl:show="new">302546</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6a9a581e-4000-45a5-8f81-e4a0ebc50d6a">15as</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_44435011-4a7c-462e-a73b-d61626b4cebd">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bfb99574-6234-45d6-ade8-c687bbe080d7">
                        <link xl:href="http://snomed.info/id/716891004" xl:show="new">716891004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_404cab61-6aff-48df-8081-9ebe69a64afb">Basal anterior fibromuscular stroma of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_17c343fc-910f-4501-94af-cd8e3b3c2a24">
                        <link xl:href="http://snomed.info/id/716891004" xl:show="new">R0-00017</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c55b6aad-3105-4f7b-ad9b-304a9383e28e">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273850" xl:show="new">C4273850</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d179e439-f029-4c92-8d77-96329bdf21fd">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=302539" xl:show="new">302539</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_447c28d3-386d-4256-97ab-39287e57aa77">13as</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1b764d40-88ab-48a2-9143-f5a5473b5c97">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1400b90f-1ddf-4611-a4a5-e780665e0235">
                        <link xl:href="http://snomed.info/id/716901006" xl:show="new">716901006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c49f68b3-ee51-4a6c-a959-b8ca5f003de9">Central zone of left half prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c16b603f-d3ec-4b12-983e-be14677a4bdc">
                        <link xl:href="http://snomed.info/id/716901006" xl:show="new">R-FFFFC</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_29c79079-7e07-47e6-bb66-779b38573dc3">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273550" xl:show="new">C4273550</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6cbcab8d-d81e-4f88-a750-4b8b98e5e05f">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=302475" xl:show="new">302475</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_50c9ab50-4865-4dde-8615-b0baab699484">7p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3bc11ac2-b192-4876-bdb9-83bb6ad8c942">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e14871d1-3948-4006-8b6a-dcb2a2e9c598">
                        <link xl:href="http://snomed.info/id/716900007" xl:show="new">716900007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_82b7c1f1-cb11-49c9-9cd1-bf31769e7d46">Central zone of right half prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_84a6680d-b487-47c0-ba7e-e54f264be2f1">
                        <link xl:href="http://snomed.info/id/716900007" xl:show="new">R-FFFD0</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3392524f-ae94-45d3-8399-4a275ede313f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274157" xl:show="new">C4274157</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f8ee2796-dc0a-44ec-be29-cc01235900e6">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=302473" xl:show="new">302473</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dc7496c4-ee23-49e8-a0be-4e89dae016a1">1p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e63cb9f0-1dc1-4a64-b9ad-5dbcdbb0eea2">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ed531c50-05a6-4cc0-af14-f1971be086a8">
                        <link xl:href="http://snomed.info/id/716937001" xl:show="new">716937001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c9034222-ffba-4e79-b99d-b53f3f38bffb">Left anterior apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_679ed5a0-7935-4e89-b261-3685a79a2083">
                        <link xl:href="http://snomed.info/id/716937001" xl:show="new">R0-00025</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_167e2506-0b21-41e7-ab78-f8699898e74b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274170" xl:show="new">C4274170</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_61b9f23f-6908-4d7f-ae1e-75d3f8407a57">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328760" xl:show="new">328760</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_83985741-bc68-47fc-866e-f195fa0f8847">12a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_df7949ca-8511-4291-b7e1-2d5a874bd552">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dd7e600f-4b4e-4ab2-8ac4-2fe6951eb0d4">
                        <link xl:href="http://snomed.info/id/716905002" xl:show="new">716905002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_81c34818-fdb1-4801-9733-b33d2a750500">Left anterior basal peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d537eac2-0f72-4e7f-8350-0b0b4e4057d5">
                        <link xl:href="http://snomed.info/id/716905002" xl:show="new">R0-00001</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_77c30489-3d51-488b-887f-b3e8f54c1a34">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273857" xl:show="new">C4273857</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8bdfebe7-9e8d-4d4b-a5b9-c9d87ec578c6">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328753" xl:show="new">328753</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e70a384d-1c20-41ce-83c9-9bda1ac1b270">8a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c12ab1e4-71b7-4778-82a0-015b649eaecb">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_614bf0da-a956-4e21-8a95-6ff4a69c83d5">
                        <link xl:href="http://snomed.info/id/716920008" xl:show="new">716920008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b9261e86-e4b2-4949-8471-efb4af627b67">Left anterior middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c2352818-cf9c-4c96-920b-648d0bc07017">
                        <link xl:href="http://snomed.info/id/716920008" xl:show="new">R-FFFB0</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_06edc81e-89a8-4375-a712-f2478ec68482">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274185" xl:show="new">C4274185</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1007affd-adc0-4b38-bfbd-35dedfe49a23">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328768" xl:show="new">328768</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8eefe90d-7784-41f1-b21f-87188d9bdfcd">10a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0c97ebd0-ad7e-41f2-afcd-44469c215216">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0676902c-c272-476b-9c76-fc3d1cc4e57b">
                        <link xl:href="http://snomed.info/id/716929009" xl:show="new">716929009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_cf9a643a-c18c-4651-84bd-dd75a8c00ad4">Left apical transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9c5f62a8-3fe9-470a-b84f-1cf3c8566a47">
                        <link xl:href="http://snomed.info/id/716929009" xl:show="new">R-FFFA9</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3c0e22ff-8857-4b1d-b329-a660250715cb">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274176" xl:show="new">C4274176</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d7fd0eba-69da-4469-bd1e-1628626a56c8">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328769" xl:show="new">328769</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_679d2e96-bcb7-4beb-94ad-2bcf55a7d198">11a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_23b68428-9695-41d6-b264-c4b2b6bd7a19">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_06210701-b4d0-492b-bbe9-38b8409cdc16">
                        <link xl:href="http://snomed.info/id/716895008" xl:show="new">716895008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_214c0c9b-7ed0-4c87-872c-d508aca8feea">Left basal part transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a59fb8b0-bd1d-44ad-9d3b-654abace942c">
                        <link xl:href="http://snomed.info/id/716895008" xl:show="new">R0-00020</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ee4b099b-40b7-441a-ba10-6309ca719d1b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274160" xl:show="new">C4274160</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b739aaf-fa32-46a3-a90a-4b9b292004f0">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328755" xl:show="new">328755</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9aa2f7e7-3323-40cd-bedd-d7e2377372bf">7a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_acbe6808-2723-4871-8da2-4c179803cc75">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3e3db3cf-85e3-4a90-a96e-31b772601ce8">
                        <link xl:href="http://snomed.info/id/716912006" xl:show="new">716912006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_03a21261-384a-4047-99cf-0bce0bb8ffcb">Left middle transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_90fb993e-567e-4fb7-9c09-4bb097f97568">
                        <link xl:href="http://snomed.info/id/716912006" xl:show="new">R-FFFD5</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_91da235b-fa43-4e7f-8e76-8aed77e979a0">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274192" xl:show="new">C4274192</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ea254c21-4c2f-4651-aef2-dc8694f1a118">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328762" xl:show="new">328762</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ff1f3d17-d525-404d-b7b2-23ec1f942fdd">9a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a65a7472-4d05-449b-8b8a-30c075033c67">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_646211f5-4a31-4bb2-9dc2-7eb64b8bafe2">
                        <link xl:href="http://snomed.info/id/716939003" xl:show="new">716939003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_61c1a192-5447-4377-8113-68ae6bb0ef41">Left posterolateral apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_598b6fc4-ed31-4033-bb42-335d0ecdf9ce">
                        <link xl:href="http://snomed.info/id/716939003" xl:show="new">R-FFFDD</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_08b00849-bf1a-4394-845f-fb1f1a5f4135">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274168" xl:show="new">C4274168</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8cc0a6ea-9a60-464a-b1c2-205c1dba7451">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328752" xl:show="new">328752</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cf455408-0ab8-465a-9f46-8445fcc395d8">12p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_be36022d-79e4-41d6-adda-a409b541d436">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2f13ffee-93c9-4b96-9512-9ad3e715564d">
                        <link xl:href="http://snomed.info/id/716907005" xl:show="new">716907005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fff31bfa-6913-4992-b041-b4729af55aab">Left posterolateral basal peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f32c7701-be0c-48eb-a073-9e3a802a39db">
                        <link xl:href="http://snomed.info/id/716907005" xl:show="new">R-FFFC2</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8b7635cd-c5fc-4602-9303-af2a2bca7885">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274197" xl:show="new">C4274197</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a223fc12-e000-4443-9c02-3406ef7cf0ee">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328759" xl:show="new">328759</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_02152983-5e29-4fb9-b537-bc4655811887">8p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a3e1fb4a-a4bd-4ecf-995a-5970bf611660">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ec331c50-fa25-47c8-963a-d4acb5ba9be6">
                        <link xl:href="http://snomed.info/id/716922000" xl:show="new">716922000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_699d6cd3-4f10-4883-b103-801fd92cf314">Left posterolateral middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_25a30c9e-37a1-4d86-9b3f-4adca0c9fea5">
                        <link xl:href="http://snomed.info/id/716922000" xl:show="new">R-FFFE9</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7f160440-f353-4735-8b2a-cfae0d4208f6">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274180" xl:show="new">C4274180</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9da24c1c-0e88-41bf-af56-125a3010ae2b">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328791" xl:show="new">328791</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_32fd1fc9-e55b-46df-bf25-27e7d162380a">10p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e740f578-fa3c-4dcc-a169-467f3c0797e3">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_989a3224-87e7-445a-be3f-0b61b54bc6c9">
                        <link xl:href="http://snomed.info/id/716941002" xl:show="new">716941002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_71456415-3eef-4e48-8aa2-19c8a20214f1">Left posteromedial apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9a894aeb-dc2c-4eee-bb00-86d0243b0035">
                        <link xl:href="http://snomed.info/id/716941002" xl:show="new">R0-0000B</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_34b9514d-947b-4f8f-aae7-12cf648ac0dd">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274166" xl:show="new">C4274166</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dc60d3b6-f83f-4a0c-8afa-8449f40c630f">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328792" xl:show="new">328792</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_12bb5662-76fe-4cb0-b90a-8269899ab123">11p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_daf7a19f-d7d7-410e-af76-9a63ce21e6d4">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_640a8e89-4636-416c-9684-edce90b6b956">
                        <link xl:href="http://snomed.info/id/716924004" xl:show="new">716924004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a97db7f6-f9fc-4847-8ed1-a2161c207682">Left posteromedial middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9a6f6dc5-9536-4904-8ac2-a16a42ace7df">
                        <link xl:href="http://snomed.info/id/716924004" xl:show="new">R-FFFB5</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_531a1221-3f21-4c5a-acf5-8d79d0bcb9c0">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274183" xl:show="new">C4274183</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ae55f2d1-3ff2-45e7-93e8-347e65c9fbbf">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328777" xl:show="new">328777</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_536ff4ad-1d68-4ce4-b541-68771ba7c510">9p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a3d39f7d-8be8-4c59-981a-39a071449854">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e10b663f-6285-4ce0-85dc-8b3eb753bc15">
                        <link xl:href="http://snomed.info/id/42320003" xl:show="new">42320003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f1662201-a31d-481b-b0b9-d36f878d7ff0">Left seminal vesicle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_efdcb0db-6c15-47e4-9367-9eda9724dc6b">
                        <link xl:href="http://snomed.info/id/42320003" xl:show="new">T-93020</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c327f28e-dc99-4d12-88bf-e9f966e2cd5f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0227980" xl:show="new">C0227980</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_af1f7110-960a-44b9-b2fb-7121c2149c34">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=19388" xl:show="new">19388</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_554218dc-62ea-472e-8f52-0b994c63a0e3">L SV</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f4acc3c3-38b1-4bb3-9b8c-f60681d31c4c">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_14ad50cb-40d8-45d5-aedf-9405ad9d3591">
                        <link xl:href="http://snomed.info/id/717027004" xl:show="new">717027004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c4f4cce9-2287-47f2-80f4-d192a9f11f97">Male external urethral sphincter</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_87832fc6-54c2-4935-bb74-1b7fffd273e4">
                        <link xl:href="http://snomed.info/id/717027004" xl:show="new">R-FFFD9</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cf0cce11-2987-4887-843d-0ee8d7ce0cf0">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0815353" xl:show="new">C0815353</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4c89d762-e12b-4e6b-9f61-d608c47fa298">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=19733" xl:show="new">19733</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_58946fff-fe7f-417e-8f94-28849cc201e6">US</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf86b56d-8051-48f1-b4ec-8e7e1cf17265">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_acf894cf-cf9a-4029-8fc0-f61c5e4c0c21">
                        <link xl:href="http://snomed.info/id/716908000" xl:show="new">716908000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9ba3a7fa-2512-44c2-be9b-c5fd37ef812e">Middle anterior fibromuscular stroma of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ff431b95-1367-4a47-aee3-0831637fc6d3">
                        <link xl:href="http://snomed.info/id/716908000" xl:show="new">R-FFFE0</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_756495bb-c748-47ee-9ae2-d4e9725d6033">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274194" xl:show="new">C4274194</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c9fd5eb8-c934-41af-8d8e-1de69f341baa">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=302542" xl:show="new">302542</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a99da289-85bd-4d58-9ae6-4a63825a3750">14as</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9fc80f3d-03b8-44fb-ad97-2bfb0389b939">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b5fb1667-e820-4c81-b2ba-6fc7652ef8c8">
                        <link xl:href="http://snomed.info/id/716936005" xl:show="new">716936005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_28a501a9-6872-49ee-8de0-638d7b140834">Right anterior apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a7c4d7b1-6c13-4c98-8c25-0ac046f2dd4d">
                        <link xl:href="http://snomed.info/id/716936005" xl:show="new">R0-00003</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_51cf508b-f146-4eba-b4c6-846d7f51bfa1">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274125" xl:show="new">C4274125</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3cf0d361-34d5-4821-935f-871b74303617">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328779" xl:show="new">328779</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d6029de6-130a-4b47-9c02-2b65d6813976">6a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e99c29f6-55bd-461f-b933-2b25716a4293">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8e933df2-ef74-476c-abbd-393c5fda8b11">
                        <link xl:href="http://snomed.info/id/716904003" xl:show="new">716904003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f85a7862-d2cf-4220-9f54-fd480a161991">Right anterior basal peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_24b2e37e-cef1-410b-8c03-d20500690dcc">
                        <link xl:href="http://snomed.info/id/716904003" xl:show="new">R-FFFE2</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_60b7f2b3-3c28-427c-a849-f7c068acb6b2">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274200" xl:show="new">C4274200</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_38b0467f-e439-4201-9903-6fd8d4ac84ad">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328798" xl:show="new">328798</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5e1da6f0-9bd2-43ac-b2b0-811d638454d3">2a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_852e4b04-6a90-4aff-a69d-40f713043a1b">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e1e9c2c2-69cb-4e0c-88e1-41b26cf9b76e">
                        <link xl:href="http://snomed.info/id/716919002" xl:show="new">716919002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_aa075eb3-0a6d-4578-b284-d56a7e1ecb75">Right anterior middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3e134b7c-3308-482a-8f06-911f8bc65ec3">
                        <link xl:href="http://snomed.info/id/716919002" xl:show="new">R-FFFCD</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_66e602cb-5fd3-4337-a630-a3f14f4f4719">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274141" xl:show="new">C4274141</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bee3aca3-d6cf-4918-afd8-27fe1fdf96fe">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328796" xl:show="new">328796</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_309333cc-605e-4fbb-8917-3deaff6e4b03">4a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d4d77989-5b40-49a5-9d82-9857dc669187">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4b47be50-508b-4899-949e-3064f79fe0f3">
                        <link xl:href="http://snomed.info/id/716928001" xl:show="new">716928001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_33e7879b-0d89-4d34-a877-2103fa54bb5c">Right apical transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1eae604a-9205-4712-969f-5df4254b0674">
                        <link xl:href="http://snomed.info/id/716928001" xl:show="new">R-FFFC1</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_554ea7d6-a4a2-4e46-8eab-2eef8485549b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273855" xl:show="new">C4273855</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f5a85b6d-4804-4036-8935-0d71f35c9164">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328773" xl:show="new">328773</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_096dfafa-d3ff-4006-9082-08fd4974572f">5a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_799a5831-cb98-4a41-bbbd-5560ef3df847">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_921aa6b3-7854-4a00-8d1c-ffbd2d251ddb">
                        <link xl:href="http://snomed.info/id/716894007" xl:show="new">716894007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_188a3d92-8ec8-46ae-817a-6796df888ca8">Right basal transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_874bd326-deca-49da-9c7f-a57c8d38c543">
                        <link xl:href="http://snomed.info/id/716894007" xl:show="new">R-FFFBE</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_540bc2ca-6e6b-4d5e-aaae-7dc564d46283">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274164" xl:show="new">C4274164</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_eb09204d-9b2b-4037-9444-23123f825529">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328780" xl:show="new">328780</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e339d7ef-71f3-43ba-a9b2-40632c6a047f">1a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0aa71153-41c1-4b4b-af50-dad278f5af9c">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_717700ab-3e16-40c6-83f1-4ac9a9121713">
                        <link xl:href="http://snomed.info/id/716911004" xl:show="new">716911004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_2cdebe5b-d507-4118-b206-cba81baaf1e2">Right middle transition zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_463a903a-1561-473e-b26f-e7fa19bf5be4">
                        <link xl:href="http://snomed.info/id/716911004" xl:show="new">R-FFFB6</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d50e8dda-2e6b-41b4-95c9-2f361a5cd44c">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273545" xl:show="new">C4273545</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_74663812-795f-407c-86c9-3ffed6a1d0e4">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328757" xl:show="new">328757</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_74f26192-d952-49f5-b139-a80b70b6844a">3a</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9c7e4111-103e-43b6-8f13-d081ba208e84">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8ee7b2e3-a8bc-47f5-9296-ddf282832045">
                        <link xl:href="http://snomed.info/id/716938006" xl:show="new">716938006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_cce3746e-e4e8-40ff-b3c3-30c1570b334f">Right posterolateral apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_eacdc2d8-ad2c-4d91-84a3-9e5e4640f5d1">
                        <link xl:href="http://snomed.info/id/716938006" xl:show="new">R-FFFC0</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9215b2a8-4de1-45b6-ae52-8a1f1937f04b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4273861" xl:show="new">C4273861</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf6e04b3-cd5e-402d-a29e-e2d7d5b26ffc">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328782" xl:show="new">328782</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c9b307ff-c337-4bb7-88f1-926ecc9e23cd">6p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fdd25d69-48ba-47a8-9089-19cb8fb5a442">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_56aa35ed-d4a3-4c70-8fd0-0d12204e11b4">
                        <link xl:href="http://snomed.info/id/716906001" xl:show="new">716906001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_94eff41a-6cac-4361-b744-5a3b1fd627ab">Right posterolateral basal peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fea9b929-3446-480f-a3f8-c7553cb8d255">
                        <link xl:href="http://snomed.info/id/716906001" xl:show="new">R0-0001E</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_72cd4b87-b746-435b-abd5-4ecfec2b8bab">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274198" xl:show="new">C4274198</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_951a3d63-ab7c-4c53-a5bf-6a78971f023c">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328797" xl:show="new">328797</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5a387e7c-a2d0-4a54-9c0d-eb51b55beae7">2p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4ec9a90e-3f0b-405b-a0b9-9f47520b3e2c">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fa1aa1bd-d8b3-4c1d-bade-5afb79e69abc">
                        <link xl:href="http://snomed.info/id/716921007" xl:show="new">716921007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6ca565d6-f526-4b61-98fe-ed33100e450d">Right posterolateral middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bc50030d-6b2b-418d-9052-3fd4754fe7ed">
                        <link xl:href="http://snomed.info/id/716921007" xl:show="new">R0-0000C</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d7aeaaec-1410-4f7a-86df-473ce1b1ab45">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274184" xl:show="new">C4274184</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6659302b-f47f-48b4-bf6d-ce995c683d68">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328771" xl:show="new">328771</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_06cd15dc-4461-44c2-8d9b-d49febe1bda4">4p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_484a5e2b-b492-47b5-87de-5aef5423c5a7">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0308a176-a740-4677-93a2-bdf40d06eccd">
                        <link xl:href="http://snomed.info/id/716940001" xl:show="new">716940001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0f421349-9822-4bcf-9d4a-8de4c0e34312">Right posteromedial apical peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e672d485-e808-476a-af46-bb0bf2cd7e18">
                        <link xl:href="http://snomed.info/id/716940001" xl:show="new">R-FFFEA</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9a60931e-82c7-4452-98af-dc037205eaf2">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274167" xl:show="new">C4274167</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a4d5de73-e18e-454f-8541-61ce9d93b038">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328764" xl:show="new">328764</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a61ff325-575e-4644-83db-f1d6706cdae2">5p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_372191fe-50c8-4877-b26d-0835519a4ab2">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ee48e88e-3327-4711-ad14-58c880eb0d23">
                        <link xl:href="http://snomed.info/id/716923005" xl:show="new">716923005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_38823e0e-46bc-42ce-b435-bc42eb95422f">Right posteromedial middle peripheral zone of prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7d020dd1-ac10-4198-84b4-b5b9a4f05ac4">
                        <link xl:href="http://snomed.info/id/716923005" xl:show="new">R-FFFD4</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a7e6ce09-5a09-474b-966b-1aace3f2126b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C4274181" xl:show="new">C4274181</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_11c78645-d148-4583-9e06-e1f36675a42d">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=328766" xl:show="new">328766</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c466a7d6-8ea0-4ab2-b781-3603f174e834">3p</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ee59da27-ad69-44f9-876f-4174a86a1de9">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a30839da-059f-49a4-b3b1-4a8c7f7eab69">
                        <link xl:href="http://snomed.info/id/74308000" xl:show="new">74308000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_bb8d3870-3ad7-43ef-a115-1f7f72c8fc45">Right seminal vesicle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5ba150cc-63be-426d-9045-f213076396b1">
                        <link xl:href="http://snomed.info/id/74308000" xl:show="new">T-93010</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f48e023b-5d85-4ee5-8608-99a3e1eb9e7f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0227979" xl:show="new">C0227979</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_83d6d657-bb8b-4335-8a24-16b33b283f0d">
                        <link xl:href="http://xiphoid.biostr.washington.edu/fma/fmabrowser-hierarchy.html?fmaid=19387" xl:show="new">19387</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7c71399a-824a-46ec-a844-d647935b3eb2">R SV</para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>


        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.6 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        <section label="A" status="1" xml:id="chapter_A">
            <title>Registry of DICOM Unique Identifiers (UIDs) (Normative)</title>
            
            <table frame="box" label="A-3" rules="all" xml:id="table_A-3">
                <caption>Context Group UID Values</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3322bcc5-7ea4-44d1-9b17-499a6a5e512c">
                                <emphasis role="bold">Context UID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_225c7fe6-91ef-424b-812b-249ecd55f194">
                                <emphasis role="bold">Context Identifier</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_25349958-e4d1-4bb0-aaa9-33d5cb03df93">
                                <emphasis role="bold">Context Group Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21c2633a-2b79-49c4-baa8-d930649479d0">
                                <emphasis role="bold">Comment</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>1.2.840.10008.6.​1.​uuuu</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <olink targetdoc="PS3.16" targetptr="sect_CID_63nn" xrefstyle="select: labelnumber"/>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <olink targetdoc="PS3.16" targetptr="sect_CID_63nn" xrefstyle="select: title"/>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        
        
        
        
        
        
        
      
        
        
        

        
        
        
        
        
          
        
         
    </chapter>
</book>