<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1932</title>
    <subtitle>Add Series Date and Time to missing Modules</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>November 2019 Voting Packet</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/10/27</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/05/09</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1932</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Series Date and Time to missing Modules</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Some Series Modules for IODs that do not the General Series Module do not have the Series Date and Time, e.g., the Encapsulated Document Series Module.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="C.7.3.1" status="4" xml:id="sect_C.7.3.1">
          <title>General Series Module</title>
          <table frame="box" label="C.7-5a" rules="all" xml:id="table_C.7-5a">
            <caption>General Series Module Attributes</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_04100f31-5424-4105-b397-e81ea26cab1a">Attribute Name</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9f6ee2bc-0c72-4acc-bd8a-3b63e075406c">Tag</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7be1655a-1548-4c66-a4a3-2f62a8898dc2">Type</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_28b73666-093e-4904-b24e-ab760754d7a0">Attribute Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8f5b6232-1f6b-44ac-9c12-72b2c8cd7c1b">Series Date</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7be95d2f-c767-4b94-ad50-67e08573df81">(0008,0021)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5cfd6f14-70e8-47db-aa04-38b7079e2bad">3</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2dba68c6-c0b1-401b-a411-d2b91b8ad50e">Date the Series started.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_83add121-f783-4c31-9eb9-4409883d1b2c">Series Time</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_32ce80e3-1e9c-4aa8-b92a-23abc45328dc">(0008,0031)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5e62a150-504a-4a7a-967f-6362384898be">3</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f86d1f93-e991-4de3-9716-2af1e9d5d269">Time the Series started.</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
        
        <section label="C.24.1" status="3" xml:id="sect_C.24.1">
            <title>Encapsulated Document Series Module</title>
            <table frame="box" label="C.24-1" rules="all" xml:id="table_C.24-1">
                <caption>Encapsulated Document Series Module Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89c6b4aa-492c-4dc0-aabf-c6b934c6c4f1">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_55340e98-0c3c-4b69-9d29-86e5445911ed">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_28b3f499-8187-430a-a182-8818ec287a13">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba09d1c7-d3df-4f09-bda2-48bad762c054">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c7df71fb-ca76-46d2-ae27-48f595654509">Modality</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1f9c1b01-6836-4dca-936f-cecc23a59922">(0008,0060)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f98f1dbd-30aa-4254-b8a6-b50fcd6d13f3">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8e91732c-5381-4e0c-9db2-369b9d4d105f">The modality appropriate for the encapsulated document.</para>
                            <para xml:id="para_742bbcfb-fb27-455a-94ed-a968bc75c756">...</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_65d2f69a-ad77-4bfb-83b7-ac9df6ba20f0">Series Instance UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92e80091-be1a-444f-83de-729e337b9d15">(0020,000E)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ace7d569-be6b-4d5e-b8a2-3c6c91f39853">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4adf5682-5271-4d63-a338-583f5a8eb712">Unique identifier of the Series.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ab6ae104-87e3-4e07-aa91-ec5415d9e759">Series Number</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_701f646d-a813-49c8-bc72-f3d4e32a9ab2">(0020,0011)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_600ecf2f-1728-436f-9c31-e1ab56ed8d7f">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_01c16c25-9ffb-48ac-9177-463248ea21a2">A number that identifies the Series.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Series Date</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0008,0021)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Date the Series started.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Series Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0008,0031)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Time the Series started.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_59fdb24c-6e36-4f21-9783-17c2d17254e8">Referenced Performed Procedure Step Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef1a28ef-5f59-49ae-b482-f9dd450d7c21">(0008,1111)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9572417-b7ca-4d6b-bb25-4ce5e9df7008">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6acde8eb-a5d2-4467-a427-49ff070237b2">Uniquely identifies the Performed Procedure Step SOP Instance for which the Series is created.</para>
                            <para xml:id="para_85ad36b0-bb68-44d8-9bc5-8c393a686cc4">Only a single Item is permitted in this Sequence.</para>
                            <note>
                                <para xml:id="para_d9cdbd42-5d99-4d51-b1ed-e9f54dd012bb">The Performed Procedure Step referred to by this Attribute is the Step during which this Document is generated.</para>
                            </note>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
      
        
        
        

        
        
        
        
        
          
        
         
    </chapter>
</book>