<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1929</title>
    <subtitle>Add precoordinated measurement CODE content item parameter to TID 300</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>November 2019 Voting Packet</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/10/27</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/04/22</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1929</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add precoordinated measurement CODE content item parameter to TID 300</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>A coded rather than text content item for precoordinated measurements is missing from TID 300. Add it and add a parameter for the template invocation.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="TID 300" status="3" xml:id="sect_TID_300">
                <title>Measurement</title>
                <para>This (simplified version of this) Template provides a general structure for a numeric measurement.</para>
                <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para>Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Coded term or Context Group for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$Units</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Units of Measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8bcec88-37d6-4561-b828-e4d6ef3790fc">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e6519c4-97df-4e09-8762-4dd0dff32912">Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$TargetSite</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Value(s) for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">$PrecoordinatedMeasurementMeaning</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Coded value for the precoordinated concept name of measurement</emphasis></emphasis></para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para>
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para>
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para>
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300">
                    <caption>Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>$Measurement</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para>1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para>M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>UNITS = $Units</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1a38665-2780-47a2-8288-b2ac487c6998">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b94e2514-7250-42fa-9b08-6b893ad01093">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30586168-f816-4111-8cdc-f11f95a81d0b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f382fab9-034b-41e1-aa6f-a7185be151b9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b72d8b6-ed15-4a08-9b5b-289774f7cf5c">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(G-C036, SRT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c07f112c-405c-4d23-be39-6a581360dcae">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_838f090d-85d8-4634-8fd7-e2fa6f6039b1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6560d8a-8154-45bf-94d2-37153ca9099f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2db623f9-eb56-4064-970f-909c99c2a31f">$Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(G-C0E3, SRT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para>1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para>U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>$TargetSite</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a041534-7087-4287-9602-af9928c73c30">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56a190fb-cd34-40de-8d6d-4eec35958b13">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d897d7e7-1ced-4087-b3ad-7137de920360">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1d9895b-c478-4112-8afc-816cb4b3edd1">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a836245-f544-4e0f-ba7f-14532c3196d7">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92ace882-b4c5-4d3c-9240-e5779a2238f9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2562d454-f655-49a8-8fab-182e76a9f03a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35dfcf1c-1a3c-4ddc-b49c-1bfbc9d51050"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1a89c74-4147-43f6-ad3d-ea013444ce4a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">16b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">HAS CONCEPT MOD</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold">CODE</emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">EV </emphasis></emphasis><link linkend="DCM_121050" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">(121050, DCM, "Equivalent Meaning of Concept Name")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">$PrecoordinatedMeasurementMeaning</emphasis></emphasis></para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para>
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>Rows 2, 3, 4, 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>The HAS CONCEPT MOD items allow the explicit definition of terms for post-coordination of the measurement concept name. Additional post-coordinated modifier terms may be included in a SOP Instance based on this Template, in accordance with section 6.2.4, or as defined by Templates that invoke this Template and explicitly define additional post-coordinated modifiers (e.g., TID 5203).</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para>Row 5</para>
                            </td>
                            <td align="left" colspan="1">
                                <para>Finding site may be multiple when a region of interest spans multiple anatomical locations and there is not a single pre-coordinated code describing the combination of locations. E.g., when a maligant, inflammatory or traumatic process spans actual or defined anatomical boundaries. There is no requirement that the multiple locations be contiguous.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8478bcd-4ae8-41d3-99e5-3029ac1c531d">Row<emphasis role="bold"><emphasis role="underline">s</emphasis></emphasis> 16<emphasis role="bold"><emphasis role="underline">, 16b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8adf7435-8928-478a-a82f-a4eabcc8d850">Equivalent Meaning of Concept Name allows the creating application to specify the preferred composed concept name representing the measurement and the associated post-coordinated concept modifiers. The concept modifiers may include those specified in this Template, in a Template that invokes this Template, or at the option of the creating application in accordance with section 6.2.4. This composed concept name may be rendered by a display application.<emphasis role="bold"><emphasis role="underline"> It may be supplied as text or coded concept or both.</emphasis></emphasis></para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        
        
        
        
        
        
      
        
        
        

        
        
        
        
        
          
        
         
    </chapter>
</book>