    <title>CP-1928</title>
    <subtitle>Add multi-energy CT attributes to de-identification profile</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballott</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/11/08</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/11/10</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1928</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add multi-energy CT attributes to de-identification profile</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.15</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Sup 188 did not address de-identification of the new Attributes that are descriptions, IDs and labels.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Add the following rows to DICOM PS3.15 Table E.1-1:</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        
        <table frame="box" label="E.1-1" rules="all" xml:id="table_E.1-1">
            <caption>Application Level Confidentiality Profile Attributes</caption>
            <thead>
                <tr valign="top">
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c5e6e8ba-34e0-4e31-90b5-bd9ed7086ddd">
                            <emphasis role="bold">Attribute Name</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d02d5580-8438-4a00-8c30-ba93530bcd31">
                            <emphasis role="bold">Tag</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_705936dc-2c42-4198-b406-ba0e61b35e99">
                            <emphasis role="bold">Retd. (from <olink targetdoc="PS3.6" targetptr="PS3.6" xrefstyle="select: labelnumber"/>)</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a8387cac-386f-4ad9-96b3-b3dcb1b1010c">
                            <emphasis role="bold">In Std. Comp. IOD (from <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>)</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fc0ff9a1-5780-4d06-861a-24ae0ba38b47">
                            <emphasis role="bold">Basic Prof.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_19ddb67a-a5d6-474d-a13f-8df27d28b707">
                            <emphasis role="bold">Rtn. Safe Priv. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5b335431-5276-4cc0-bddf-93b6d107226e">
                            <emphasis role="bold">Rtn. UIDs Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8317e0cf-0080-48f9-8040-1f49a4478c0f">
                            <emphasis role="bold">Rtn. Dev. Id. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1ba661a2-a572-420a-95c1-bc1bf694a70e">
                            <emphasis role="bold">Rtn. Inst. Id. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_796841da-6b27-4558-99c9-99503edccc6c">
                            <emphasis role="bold">Rtn. Pat. Chars. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_edac8181-290b-4f9c-945d-5dfc7b1a43fc">
                            <emphasis role="bold">Rtn. Long. Full Dates Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6305752d-56e7-4f4d-b9d8-e5052fcd6eea">
                            <emphasis role="bold">Rtn. Long. Modif. Dates Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_84f3b128-8fe5-45bc-b04e-abc483377b06">
                            <emphasis role="bold">Clean Desc. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0adc5d55-1196-4265-8ee1-b205103c96f1">
                            <emphasis role="bold">Clean Struct. Cont. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5e74e547-b6fd-410e-9c09-b271915c3eeb">
                            <emphasis role="bold">Clean Graph. Opt.</emphasis>
                        </para>
                    </th>
                </tr>
            </thead>
            <tbody>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para>Decomposition Description</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>(0018,937F)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>X</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para>C</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para>Multi-energy Acquisition Description</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>(0018,937B)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>X</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para>C</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para>Source End DateTime</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>(0018,936A)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>D</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para>K</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>C</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para>Source Start DateTime</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>(0018,9369)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>D</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para>K</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>C</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para>X-Ray Detector ID</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>(0018,9371)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>D</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para>K</para>
                    </td>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para>X-Ray Detector Label</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>(0018,9373)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>X</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para>K</para>
                    </td>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para>X-Ray Source ID</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>(0018,9367)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>D</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para>K</para>
                    </td>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
            </tbody>
        </table>
    </chapter>
</book>