    <title>CP-1903</title>
    <subtitle>Add laterality parameter to TID 300</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Submitted</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/04/26</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/02/28</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1903</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add laterality parameter to TID 300</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>A parameter for Laterality is missing from TID 300, and some invocations may want to specify
                        which laterality is to be used.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="TID 300" status="3" xml:id="sect_TID_300">
            <title>Measurement</title>
            <para xml:id="para_77bd792c-bd9d-4e95-bb1e-f3846ddcda7f">This Template provides a general structure for a numeric measurement, together with evaluations of its normality and/or significance, and the inference source(s) for its value. This structure is instantiated by inclusion of this Template with specific contextual parameters from a parent Template.</para>
            <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300_Parameters">
               <caption>Parameters</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e78884e8-2fba-44cb-9543-7b13a3f3d74f">Parameter Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_87aed517-66ec-469b-848a-051450840c1d">Parameter Usage</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e039a3ff-536a-4dca-bf00-b2d2fa99111c">$Measurement</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a5457f0f-7d97-406d-aa13-d6be91f9b149">Coded term or Context Group for Concept Name of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f6d70f93-7707-424a-9d79-3adcab4db4c0">$Units</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3badc168-22a5-4682-9b57-047d848b2f30">Units of Measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6989484c-b1da-4d6a-bda3-d9a7d3583ca1">$ModType</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d3979d08-a959-4113-aa01-a1840e7cb7d6">Modifier Name for Concept Name of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2220407e-bc25-4ccf-8b5d-0c95d1ddf80f">$ModValue</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b95a5982-014a-4d8f-a6a4-c5fb5c4a1f7c">Modifier Value for Concept Name of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c8bcec88-37d6-4561-b828-e4d6ef3790fc">$Method</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e6519c4-97df-4e09-8762-4dd0dff32912">Value for Measurement Method</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d22fd402-fc81-4e8d-a0de-24ba7e68e491">$Derivation</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a2abc1bf-a237-476b-adef-31ef6cada34e">Value for Measurement Derivation</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_336246da-7a84-428a-9e3e-412fdc412444">$TargetSite</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eb6a2b99-857b-4083-a92f-36f182326bc7">Value(s) for Anatomic Location of measurement</para>
                     </td>
                  </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">$TargetSiteLaterality</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Laterality Value for Anatomic Location of measurement</emphasis></emphasis></para>
                       </td>
                   </tr>
                   <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a0007a22-85ae-4827-a0f6-8e9bc75e16c6">$TargetSiteMod</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6bddb6e6-83a3-4167-b6f2-b5de271ed0bc">Modifier Value for Anatomic Location of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_380b1baf-5ace-4c43-b1ee-b425172579c8">$Equation</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2aed46c6-eac2-496c-882c-8953fb18a4fc">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_311f48b5-37c5-440e-8687-ff61aac2c7e2">$ImagePurpose</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0291ccff-9df5-4b97-a117-5f245e2d5d4d">Purpose of Reference for an image used as a source of the measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9972894f-aa6a-4168-83c4-0a734f412a88">$WavePurpose</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_82836268-0d2c-4de6-823f-d567f7fc929e">Purpose of Reference for a waveform used as a source of the measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5b3fff08-495a-43d7-8d44-8a00cb2be52b">$RefAuthority</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0a69d6cd-aaed-4021-8451-c1abe771282d">Bibliographic reference or authority for statistical properties of a reference population</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_332e3c5f-951e-4610-96e9-d9e7281fcb11">$RangeAuthority</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5fef43e6-99a3-40cc-b156-c9054b6db484">Bibliographic reference or authority for the normal range of the measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c441e1b9-7b0b-4e20-b439-5fb3657634c0">$DerivationParameter</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c55737a4-e74a-495a-a5f0-a2ad15221e59">Coded term or Context Group for Concept Name of a derivation parameter</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2e779ad8-08f2-45ac-9c31-29162f80ae8d">$DerivationParameterUnits</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_76ba2922-f81f-49d9-83b3-8ef04f67c183">Units of derivation parameter</para>
                     </td>
                  </tr>
               </tbody>
            </table>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_ab8fefe1-5cfb-4d98-bd8f-473072340e65">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_ef0dbab2-a679-4f50-95d5-3f82597e6279">
                        <emphasis role="bold">Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_a17f8f3a-4c87-4b2e-8c92-218843e7986f">
                        <emphasis role="bold">No</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300">
               <caption>Measurement</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_72040574-5d06-4448-92d3-65d64029aec2"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6dc1a5bb-799d-4ce7-b116-2de6f00399b0">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ada3f541-03e1-4c32-aca3-f7f3d0de93e9">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_34201b00-0939-4acb-975d-63b09c385b07">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_104a2ec7-1391-48f6-b7dc-c5f94a8bb57a">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0699ebc9-be03-4846-a7b1-e8c504fd0ae9">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_40849f85-f55e-4dd9-bc80-7af5c0e2a872">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cd9bf78e-2ee9-47a9-8a55-5cf98072a759">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9856b597-aeef-4056-a98c-25b47f0aabcf">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8e932889-0764-40b5-9f5e-ac3845d6f933">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4b175a93-7c5c-48bc-a5e5-380db6283009"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6ec6fe93-5cb0-4758-8adc-deef5678010b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5fe8320f-931e-4eec-91a8-f8d7ae6d7f00">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_48165cbf-5ff1-4353-9c7b-c05569a0066b">$Measurement</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a6d1fd64-a1d1-4245-8dc5-88b325d3094c">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5ab6a36e-54ef-41db-a7c7-de35a9843624">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5043dfda-6fa9-4044-b601-cb8254bff80b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b0e7cc06-ed22-40d7-ae42-3e8831a76b76">UNITS = $Units</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c515a4c2-545c-43c4-8e41-ade857100b6a">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c94a32ec-4213-4104-9bab-c3f6db880f93">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_689822ca-4490-4ddc-ab4b-fa40eaaf2ee0">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7fdc1a0e-c8a0-46d7-96d9-6c3d8ee2531c">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1b0eebe5-a3b6-4489-8519-995ab0fb2387">$ModType</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_72a99565-a981-43c6-b839-2ea70017869b">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9f7c2de4-d8f4-4da7-b290-b85c8d6374a9">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f35b74d0-e5b2-43a6-aa54-fe99d4fb9621"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e9202f3c-77aa-4877-8002-f52a780921c3">$ModValue</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d1a38665-2780-47a2-8288-b2ac487c6998">3</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b94e2514-7250-42fa-9b08-6b893ad01093">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_30586168-f816-4111-8cdc-f11f95a81d0b">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f382fab9-034b-41e1-aa6f-a7185be151b9">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1b72d8b6-ed15-4a08-9b5b-289774f7cf5c">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(G-C036, SRT, "Measurement Method")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c07f112c-405c-4d23-be39-6a581360dcae">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_838f090d-85d8-4634-8fd7-e2fa6f6039b1">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f6560d8a-8154-45bf-94d2-37153ca9099f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2db623f9-eb56-4064-970f-909c99c2a31f">$Method</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e5425fb-b11e-4ce9-8481-bf4a3747daf4">4</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d6b34bf6-827a-40ba-8b4b-be7b2de154d3">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_04f58196-f7fe-45be-b29e-ae83c4d92fdc">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5542c40a-7059-4932-b225-434e716ad737">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7b90b1fb-e270-4b78-800b-1d187de4e1d5">EV <link linkend="DCM_121401" xrefstyle="select: nopage">(121401, DCM, "Derivation")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ca8df5bb-1433-4349-8f74-72b58b00b6d9">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cda9ee73-45c3-402d-8c97-9b7488003a2b">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dabc7969-5f11-4e95-90a1-c456bcbdb6a0"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4c43c691-50c8-4531-a525-c7ee0892e657">$Derivation</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_842a90c7-9b2c-4e1b-9d86-07032d12440c">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e5831500-d717-4acd-b9f0-e1830aa51c47">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5bcc1fd5-adc6-40f2-9d60-ac63e06e3ae6">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52d994f1-7970-430c-98c6-d6f793b4fc94">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5eb269ab-ac5b-4d94-8a57-65f11a3120c3">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(G-C0E3, SRT, "Finding Site")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_620460a5-326b-427c-bbf4-b91e1aadb9f0">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a5fb68de-67b6-48ad-a052-670d176b1a63">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_721786ea-c21c-4c3a-9548-550c54e19cd9"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5ecabefa-537a-4f14-8b77-f5d7e7abc868">$TargetSite</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d351ac50-bc5b-4990-95e0-590c7c311491">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2ea5b580-7476-4ccd-bf8d-1c4aae332342">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_53959fa5-9bba-4765-80fd-5b7a9880ddc8">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e500ea97-1971-4b1e-b316-09423b1e2458">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_55011eae-faab-453d-89c5-60f2b8e7a403">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(G-C171, SRT, "Laterality")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0961a671-0b3c-4ded-978a-5830e6c0880e">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_27501979-c2eb-4352-a929-85fa10dc148c">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d067a1e3-0284-4cfc-beac-2c127ea50637"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">$TargetSiteLaterality</emphasis></emphasis></para>
                        <para xml:id="para_760eb9f5-5cb5-4415-930b-9df9a996ac58">D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c84a9a9d-404b-45f3-95e6-a0788c85a1e4">7</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9fb178ea-cdaa-40bc-be05-5206fc09fbf1">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_69f456db-3070-400c-bc29-ee9e3e11d64f">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c49d44f8-3d49-40da-a2f4-70949603f29c">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ae97e081-9e86-4c97-90d2-d44ff283b411">DT <link xl:href="http://snomed.info/id/106233006" xl:show="new">(G-A1F8, SRT, "Topographical modifier")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2ce576e6-dbff-44ee-a636-8edcd0056567">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d790e090-8302-446a-a659-1c295bfc889d">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4031f3f1-b19e-47da-b68d-974b820fddb1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_588bdde1-6eb6-4381-9df6-bebc5afefb83">$TargetSiteMod</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_55fe4e86-cca8-4940-a540-f4671dc0299f">8</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3023b9dd-13cd-4226-8581-b965fcf2707b">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fcd20d74-1731-4c10-a82b-f5f833fd15e2">HAS PROPERTIES</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_43b37530-680e-4a91-b528-d23f15ae3074">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_48f871f5-996a-4c76-9e96-4770562ac907">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5c29e082-0dcf-4fa2-addb-92519d41714e">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_690ef0da-0abe-4c43-909d-1da7dbcdf06c">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fd9608ef-d2bf-4299-ba69-b5085bd20e57"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1724ebe0-9179-4a20-a841-10c211c21038">$RefAuthority = $RefAuthority</para>
                        <para xml:id="para_458c2786-5228-4d78-87ec-e3afc106df26">$RangeAuthority = $RangeAuthority</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_43381e20-6ef0-4650-9d9e-da46ec75ba79">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_daee4ae1-1990-4e4b-8bbb-6b005058e282">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4f26c7f9-c49a-4ca2-8858-5c435b7ba3a3">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3d9d6bef-6713-417b-bf49-7b47aa74b693">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fb72713f-a9f4-4dd1-ae98-b38b33de4880">$DerivationParameter</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a1c094ed-6a6b-4b41-8f22-1d353f747243">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8de34b01-9262-4b03-9511-a5aa39fa4794">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b4775203-ee1a-4b1f-a1cd-4c54d7fe8dab">XOR Row 10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bfcb79da-82ef-4927-9a4f-a996dd7c6757">UNITS = $DerivationParameterUnits</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dd9992da-41ce-4e0d-92fe-86318d362bd7">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_48f7e292-83e6-4fd0-8fe9-5ad09f47f479">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_84f7a34d-f097-4ab4-9090-c41cc80d520d">R-INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_baf0060c-0a8a-4ef3-bc44-0d8b2b551943">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_625ca83b-7a41-49f7-85e3-3438077fb640">$DerivationParameter</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9250282c-225f-47fe-af9d-c8792a8deb2f">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1c647934-4d63-4c9a-b7dc-4d86f52c1df5">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_59c20b99-32ea-4634-91d5-dbe8957d0757">XOR Row 9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7fd8f155-8c00-4238-9d8d-5871d87443bc">UNITS = $DerivationParameterUnits</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_10e094a4-53db-45d0-92fe-b6b6d42d0a13">11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5766072c-5bd3-4569-acf4-6daeb654f73f">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_85e15b2f-722e-41e3-9a73-84710fd3cbaf">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_03dfdd98-b520-4631-86c9-fb0be07aa719">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0dec0e69-4ca9-46b7-8078-b1d9eeea7c9e">D<xref linkend="sect_TID_315" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1d2b6f4b-1493-4e02-aeac-6d3e9879447d">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_aaff5d2c-9786-4aed-a9d9-6e6bcedbb7f9">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d8041e0-b30d-4e10-81ad-3b929b364a05">XOR Row 12</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_70492950-ae80-4731-b562-31b8b1b33f47">$Equation = $Equation</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d2fdd423-32ea-4648-b480-9d09020900f9">12</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_67bae056-7e0e-4030-ad90-6efa9cfe1d59">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d30b8d9-4cc4-420b-aeff-12193d252f89">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6fb0a06f-4888-4155-883e-e2e2a9d1133e">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8dcdc31f-b3d8-479f-b25f-67ef7ecf2501">D<xref linkend="sect_CID_228" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5b8bd265-dec6-4c3a-a698-b195890ca5e8">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a76c7edf-04cc-4626-9af1-9fcc2f783890">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f5c175e6-a7af-4f17-ac9b-54f386e648ea">XOR Row 11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5a623f5b-403f-4444-a751-c3f205c9f538"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_770d16b5-21b5-4887-96bd-6aeaf6afd2c8">13</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_10c8009f-cdf8-481e-a705-02fa7087fc41">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b3918619-21e2-4ed1-b694-45f56b4953aa"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_161efed5-07f7-4bc4-9c2f-baffaed7e8f1">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bf78b3b7-4ed9-47bf-88a9-18efa573270c">D<xref linkend="sect_TID_320" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e1a45d45-0533-4a14-8fba-e85f2a151d8f">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_72e4002f-993f-410a-99d7-d699a37f8340">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eaaa3c9a-40ef-4fa0-82e2-39369442ba24"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_22d6c3ff-aaca-45d7-b0a6-d0109f903293">$Purpose = $ImagePurpose</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0f1f348a-5796-4a87-9ba3-f2889749259b">14</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_451e74d0-aac0-48d2-99fe-d88c8f19c95e">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_efe5adcc-e9c9-4812-badf-d6d44e61aa4b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c40f07c9-ca79-4b2f-8065-7325242d588b">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e79da970-e41b-4528-b581-450ab8af39d1">D<xref linkend="sect_TID_321" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c274ef43-d146-4065-9802-fbe6c4f48ca2">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3e6d8f0a-39ac-4c87-972c-e242109f5fe1">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8ea7f370-a961-4816-867e-e6d3d41763d2"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_594b4882-e970-47db-9edb-c64c94f3421c">$Purpose = $WavePurpose</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c7aa30b0-48fa-47d3-b01f-526dbfd309fe">15</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_de9abf82-2580-4ed2-b827-66fd38bd0bb8">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_248194c6-08ea-4081-a987-67ee3386cfdd"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e5aca031-f439-4c73-93e7-04a9349d9f57">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_03e11b2f-4ca7-4965-a63f-d424952bfc53">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_41f7b608-3448-4e63-af78-f8b995bdc738">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0dcd4a6b-302a-4a27-8895-a530a154ee07">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52ef5229-812f-4efb-ad81-46d5454f112c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f5a0cce9-8350-4e8f-80ed-f5d55206196b"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4a041534-7087-4287-9602-af9928c73c30">16</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_56a190fb-cd34-40de-8d6d-4eec35958b13">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d897d7e7-1ced-4087-b3ad-7137de920360">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d1d9895b-c478-4112-8afc-816cb4b3edd1">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8a836245-f544-4e0f-ba7f-14532c3196d7">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_92ace882-b4c5-4d3c-9240-e5779a2238f9">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2562d454-f655-49a8-8fab-182e76a9f03a">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_35dfcf1c-1a3c-4ddc-b49c-1bfbc9d51050"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b1a89c74-4147-43f6-ad3d-ea013444ce4a"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_26c23e39-a9c1-4701-98a6-106282354629">17</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cc5a3807-a0c7-4d54-8052-d82df186390f">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8cac7bd7-9c79-4ce1-a84f-242d236c7ef0">HAS OBS CONTEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d5d1c26-bcdb-47f2-ba7b-63bfc34170ef">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f59c744d-2c77-475f-875c-a9dd0dd3e259">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c39a5a76-3780-4adc-9520-3a00ee799552">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_35798212-6c86-4213-bba5-94e3d4b03a09">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b38af8cb-5096-4c9b-a325-9a5b55dc1a3a"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fd31b1f0-0ee9-4a19-8749-73a389d7cd88"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_673b4f2b-1fd4-42c3-be28-2691c914334a">18</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f93ce24f-3cce-44b5-9f68-d29922a19e46">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8ec8b82d-6fae-4ff4-b67a-531effecdc45">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d6706747-38ef-49db-a6a8-2751edfb08d9">COMPOSITE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f828a919-5902-43ad-b84c-7be92deb8eeb">EV <link linkend="DCM_126100" xrefstyle="select: nopage">(126100, DCM, "Real World Value Map used for measurement")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a8a2b73a-12e7-4d5a-8325-a62f25249248">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8dbd6f45-fb6e-4182-b964-a80797c29990">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_202d1931-abc7-450b-bfc3-5abc88d95a7f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9054b3b9-cd7b-4eb5-9a63-a9b44b2200a7">SOP Class UID shall be Real World Value Mapping Storage ("1.2.840.10008.5.1.4.1.1.67")</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_34625822-8896-42ed-b521-0531c03174c9">19</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_110b18ac-27da-4e25-b8d3-5e3fb7964492">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_edce7dc5-cb16-4585-9226-e1e35e81564b">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a690c6ad-8e82-4829-bc89-20e99aec550b">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_183a95cc-a257-4743-9765-b8b2e889ae16">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e0678672-8b48-4285-b9f3-796f47903fcf">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c8517cbc-dbf3-44b5-bc57-8782ac895159">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5005f9fc-75ba-42bf-a3e3-74b3161efaf5"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_be8acca7-0043-4ec7-901f-46c966708429"/>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_c568a2c1-03b8-4849-9910-d9efaf957365">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_effc493f-84f6-437c-84af-31ff7bf9c06e">Rows 2, 3, 4, 5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_33fc3488-12f8-4222-ad96-24b55739f20d">The HAS CONCEPT MOD items allow the explicit definition of terms for post-coordination of the measurement concept name. Additional post-coordinated modifier terms may be included in a SOP Instance based on this Template, in accordance with section 6.2.4, or as defined by Templates that invoke this Template and explicitly define additional post-coordinated modifiers (e.g., TID 5203).</para>
                     </td>
                  </tr>
                  <tr>
                     <td align="left" colspan="1">
                        <para xml:id="para_fcb505ed-af0f-4b3c-a679-ff3afdfa0d41">Row 5</para>
                     </td>
                     <td align="left" colspan="1">
                        <para xml:id="para_eb15fbee-f367-4d74-9be2-986aab9259f2">Finding site may be multiple when a region of interest spans multiple anatomical locations and there is not a single pre-coordinated code describing the combination of locations. E.g., when a maligant, inflammatory or traumatic process spans actual or defined anatomical boundaries. There is no requirement that the multiple locations be contiguous.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_77cb86d4-242d-4dc3-aae4-96cae1a4324e">Rows 9, 10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a50d2d4d-b98c-4f68-8e87-61e2fad1c693">The INFERRED FROM items allow the specification (by-value or by-reference) of numeric values that were used in the derivation of the numeric measurement of Row 1. The nature of the inference is not explicitly conveyed; it may be implicit in the Concept Names of the measurements. Inference by-reference is valid only in SOP Classes that permit the INFERRED FROM relationship by-reference.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f8478bcd-4ae8-41d3-99e5-3029ac1c531d">Row 16</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8adf7435-8928-478a-a82f-a4eabcc8d850">Equivalent Meaning of Concept Name allows the creating application to specify the preferred composed concept name representing the measurement and the associated post-coordinated concept modifiers. The concept modifiers may include those specified in this Template, in a Template that invokes this Template, or at the option of the creating application in accordance with section 6.2.4. This composed concept name may be rendered by a display application.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_228b5e1b-b7be-434e-a77a-56dd1279b471">Row 18</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a7b31254-30fb-4b6d-9c23-60fc0150cf6e">Row 18 is a reference to an RWV that describes how measurements were made in units that differ from the stored pixel values in the images referenced in Row 13. E.g., for a PET SUVbw measurement, the mapping from activity/concentration units in the referenced image that was used (and which may be reused for measurements in the future) may be encoded in a referenced RWV instance. This reference overrides any reference in an including Template (such as for a Measurement Group).</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>
        
        
        
        
        
        
      
        
        
        

        
        
        
        
        
          
        
         
    </chapter>