<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1846</title>
  <subtitle>Replace DCM code for circumscribed with SNOMED code</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/01/17</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/07/18</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1846</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Replace DCM code for circumscribed with SNOMED codes</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Use SRT:R-4205A (SCT:263706005) for circumscribed instead of DCM:112142; did not use SRT:F-01741 "circumscribed lesion" since not used only for "lesion".</para>
                    <para><emphasis role="italic">[Ed.Note. Have added 263706005 to SNOMED-DICOM subset CRS Request ID 738550.]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
      
      
        <section label="CID 6120" status="3" xml:id="sect_CID_6120">
            <title>Chest Border Definition</title>
            <note>
                <para xml:id="para_3d38cd38-a203-4258-89cb-20202a2f9cdf">Original source of terms is [Fraser and Pare].</para>
            </note>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_8cd2c1a2-f255-4964-8cd4-0ed569024ecb">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6120.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_6120.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_6120.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.440.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_217206c7-5c26-47f7-a694-8abc5a2a2199">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_0520e1b1-f1e4-471d-8932-f9b736414b0b">
                            <emphasis role="bold"><emphasis role="strikethrough">20030108</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_132146e1-6a7e-45d5-a03f-3f2ba6207694">
                            <emphasis role="bold">1.2.840.10008.6.1.440</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 6120" rules="all" xml:id="table_CID_6120">
                <caption>Chest Border Definition</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4613854-cb54-4cc5-a5ca-51e8ea6ecef7">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b9de15d3-685c-4ad6-bb7b-6337ffb5ef21">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58f342e4-16ef-46f8-80b2-00f1c819fb54">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e27d4eb2-026a-4553-b789-3f7b4ab137ff">
                                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a97b113-0fe1-48ce-ad36-1f0283a0470c">
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_224095f2-013e-4ea2-ae18-1782fec3a89e">SRT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc9f847a-0b22-448b-be79-7deea25f0755">
                                <link xl:href="http://snomed.info/id/260409000" xl:show="new">R-40771</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_12c4c88e-23d8-4af0-95dc-94cfc414d817">Well defined</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d3a486bb-86e9-43d4-997c-802770e6ecf3">
                                <link xl:href="http://snomed.info/id/260409000" xl:show="new">260409000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c6229efd-38e8-43ab-8e7f-e06a4570c561">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0442825" xl:show="new">C0442825</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc9fccc7-1bce-4e11-992a-2bd7ca910180">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1aaad4e1-e58b-492f-ab0a-6d80f86645b9">
                                <link linkend="DCM_112137" xrefstyle="select: nopage">112137</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8a262b7c-8e48-44b7-85bd-61ef204f6ebe">Sharply defined</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f8e9ae2-4d45-466d-ae00-b03b6347dce3"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7bdc573c-7646-46c6-9b63-6961bfd9edd4"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b27affbd-ebe5-434c-abe0-ace1c465831f">SRT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3908a0b2-7731-4a01-845e-5eef3f424a8e">
                                <link xl:href="http://snomed.info/id/300841009" xl:show="new">R-428E7</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f844cf57-aa5d-4995-b2da-1de14af51d65">Poorly defined</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e71f1e09-9ded-4ff9-9927-1764a6a14a87">
                                <link xl:href="http://snomed.info/id/300841009" xl:show="new">300841009</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_706f6ecb-d0a6-4df7-a384-28cbedbbbcb5">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0577553" xl:show="new">C0577553</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7cc07064-d831-4b07-bc96-b3234454084c">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_25251e4f-0506-4948-b2a9-adbd2bcf44fe">
                                <link linkend="DCM_112138" xrefstyle="select: nopage">112138</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3f30f354-5fdf-4746-a78c-0dc06b97bfec">Distinctly defined</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54bc4b7e-574d-4cf7-842d-73c6a219b112"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_843c3d66-b005-4b55-9752-57296745e8df"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6a9edbee-c98b-47c6-8ab1-c62c05f9eddf">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a5e8cd26-865c-4a6f-b69d-3b5d4fe7961b">
                                <link linkend="DCM_112139" xrefstyle="select: nopage">112139</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_12fee678-f981-41c9-9331-bc154ddb26ee">Well demarcated</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ca44d7f-c0c2-4ae0-a138-4168d1f77578"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc7a9ffe-8741-4512-9329-9b7995b3a3c9"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a23142de-1e7c-47c7-a169-c2d490e6314c">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06edcbc1-f3f0-4e61-9297-cf62c2e9104d">
                                <link linkend="DCM_112140" xrefstyle="select: nopage">112140</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_31a8b359-8ed6-4088-9348-6b0c04715db4">Sharply demarcated</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a4e6a535-0d32-4129-8a55-3ccc9c37facc"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78a52573-ddb6-4107-99ab-34a06e3bdedb"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b30614e5-49ab-4a5b-a3a6-e9f5db147703">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e2f18a7-4912-4ea4-9798-108a23719971">
                                <link linkend="DCM_112141" xrefstyle="select: nopage">112141</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bc754e3c-7c9c-411d-8208-fd62e0a15f0e">Poorly demarcated</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b0bd86e-2546-48e7-a498-d74902505fd7"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c2fe1e4-17a9-4304-86e1-f81f31a9ae96"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac0907ff-99a5-463e-9cfe-9ddc3690ac9e"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">SRT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9774bc2-8999-47cb-a146-8e38c40dbcb3">
                                <link linkend="DCM_112142" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">112142</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/263706005" xl:show="new"><emphasis role="bold"><emphasis role="underline">R-40771</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0e4ce977-fd97-4999-958f-17ada0aabce8">Circumscribed</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4fb47530-062f-49b8-b2c8-3fc788f0ef37">
                                <link xl:href="http://snomed.info/id/263706005" xl:show="new"><emphasis role="bold"><emphasis role="underline">263706005</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86e92727-dc60-482c-bbe9-3c6a3b890bc7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1282914" xl:show="new"><emphasis role="bold"><emphasis role="underline">C1282914</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">
                                <emphasis role="bold">Definition</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">
                                <emphasis role="bold">Notes</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_112142"><emphasis role="italic">112142</emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3c220424-f6f0-4cf5-ad52-5baa83cc2933"><emphasis role="italic">Circumscribed</emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a928fd68-1a73-4ddb-bebe-e862ce23be2e"><emphasis role="italic">A shadow (opacity) possessing a complete or nearly complete visible border [Fraser and Pare].</emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_36f27386-9489-458a-b08b-4970d94a58c8">
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired. Replaced by <link xl:href="http://snomed.info/id/263706005" xl:show="new">(R-4205A, SRT, "Circumscribed")</link>
                                        </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
      
        
        
        
    </chapter>
</book>
