<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1845</title>
  <subtitle>Add description and example for ROI distance measurements with coordinates</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Jan 2019 Voting Packet</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/11/12</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>QIICR</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/07/07</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1845</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add description and example for ROI distance measurements with coordinates</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16, PS3.17</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                  <para>CP 1386 added planar and volumetric ROI measurement examples to PS3.17 and illustrated how to encode related linear distance measurements such as for RECIST or WHO when there were no end points specified, but did not show how to encode linear distance measurements for the same ROIs with explicit end point coordinates.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
      
      <section label="TID 1500" status="3" xml:id="sect_TID_1500">
            <title>Measurement Report</title>
            <para xml:id="para_451fd560-e4eb-4e0d-bbbe-a2b2bc35cfdb">This Root Template encodes a list of Measurement Groups each containing lists of measurements, together with any derived measurements.</para>
            <para xml:id="para_05032633-832f-4009-aa1a-4cd0169bbcf6">Each Measurement Group is identified by Tracking ID and UIDs.</para>
            <para xml:id="para_ae0f46e9-777b-41b2-9bcb-f73d2d26cdc4">An image library is available to describe characteristics of the images referenced by the measurements, if any.</para>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_dc288621-3a74-4a7d-96e1-b497f9db2c31">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_3d90285a-5fef-466c-a809-b84a2ea3bd77">
                        <emphasis role="bold">Non-Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_554a2a02-c45c-4450-86e5-c176d0b47f9a">
                        <emphasis role="bold">Yes</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 1500" rules="all" xml:id="table_TID_1500">
               <caption>Measurement Report</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7f96ef72-3739-4709-a6f5-d3c609e4ec05"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_eb663436-d709-454e-ac93-98682212c9f0">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6142a93b-0f6d-44a4-8494-fc3299ba7c21">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_81a6fa58-162c-4816-971a-d0a224744ee1">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_97622db7-889d-46d0-a1c0-605bfed0f4c7">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_feb517dd-7464-42f5-9f1d-496753de6be4">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_220e6ae8-5f33-4f58-b426-f41cd8fd2bf4">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9af3785d-8f23-4d07-809d-5639784468c9">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_80f6672b-b0af-4725-adc3-e4e8c7e83695">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3321887d-8899-4314-b289-3d0e04bcdf8f">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fe0e84e0-be0d-437f-8baa-f2478513e5ee"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d8ae3ff8-c9ea-42bf-96e0-2414f44efbcf"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_85dac8a4-19f9-4283-bd59-d51aa905412d">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6e81e20b-a511-403a-893f-29ce62ab8e77">D<xref linkend="sect_CID_7021" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5b5a81ce-2cb2-47bf-9730-858f4fea4387">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0b360053-7fdd-4be5-91bf-eaea1c56d55d">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ca0229a7-7804-4c95-b314-b59248fade6c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c53c5359-96e3-44c4-8875-94dba07faea0">Root node</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d5ac092d-eeaa-45ba-879c-a39bba6c2100">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1705bda9-2729-433b-b8c7-c5b5f168fd7c">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e5e9aa3d-f666-40ba-afb9-be0318db6abb">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_41d18321-138a-49b9-99b0-d9c6299e1ebd">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b3a1d138-27b3-448d-a98e-c3786582374d">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b4aa3aa6-3fce-42c4-8886-f07a6f72822c">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_28838a6e-bd40-47a2-93a5-8102b4f17ca3">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_11daccbc-892c-47c4-8886-974b5f559550"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d9cb3169-601e-461d-9fa0-c53633bd9a32"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9d0b694f-7502-4855-8593-331163f0295f">3</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bb033089-9e52-48e2-aa2d-210196ea542e">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_769bd3a1-4bec-4f66-8dc7-ea4ab693e9cd">HAS OBS CONTEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_894b2787-c1b2-409d-a4a1-5087ded35704">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0bd4622a-9209-44c6-b887-bb1bf832faa9">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e8f59bbe-d412-41ee-9f51-b64c959314dd">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_19d56cdb-e2e7-428a-bc46-0c106b449f0a">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52937701-d101-4a96-8690-0878f00ad37e"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b6f420ac-47ed-40c3-897e-83af35788099"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_de6b0f6a-bca6-4d64-9c8c-02fee993db8d">4</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_73aea91c-c269-4b53-b5b7-f83f9759f5ba">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ca90082e-d67a-4689-9524-8db7e75a95f6">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_21119694-7dc8-47bc-b79e-a3aaef33a4c5">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a37e0410-bb3c-4aa2-8dd4-f4e2d2857fc5">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_36edc419-b874-43a5-ac21-02225e5f68c0">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_72c5b1eb-2c13-45c7-8bae-707a90971c12">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5bf111ee-8cc1-47be-b116-cf1a9c9c301c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f8377a8e-6a5d-4f93-b11d-07aa93711f36">B<xref linkend="sect_CID_100" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_69135bd9-e619-4010-bfb0-9a26882096f3">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_089ee540-5798-4812-8fe2-920e783d10d6">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_20c193a9-b9d3-465e-a85a-6de1184ad979">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f9ea4a21-6c60-4346-888d-9fc4442545e4">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cbf297e0-931b-4014-bc16-7be446cb7cc6">D<xref linkend="sect_TID_1600" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c1a95d6c-24ab-4b0a-ac89-72ca698fb5b6">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_44e96e95-2fb0-47e4-adf3-2411b755dc94">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_13e3ac11-53fe-4caa-8543-ade0f92b9840"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dbc3a6cc-0958-4084-96b2-9e0f8cda7d1a"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c8db842c-0b5d-4809-b5f7-5414422e2aca">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_acd4ceff-ae4f-4e83-bc99-27092e318603">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bf056d16-e8ba-482d-8ddc-d5113320cf49">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3ff0b318-d282-4163-9f2e-fdac666bad46">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9a55999e-9b7a-4082-a550-f4cea95ab6e0">EV <link linkend="DCM_126010" xrefstyle="select: nopage">(126010, DCM, "Imaging Measurements")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6b3b7a9e-eb99-4f87-a6e4-6cc3e8513983">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_34df0c4c-cfa8-4c66-a27d-de2b8d9e3f85">C</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_37a3cb9d-3117-401d-b28a-44ba2e697fc7">IF row 10 and 12 are absent</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_db8f2474-f267-4c5a-a382-e6c9459b921d"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_96d6cfbb-9f8d-4203-92f0-dc6f05c2d0a8">7</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6ef2d231-13a5-4959-a821-9506f815bff7">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3f15deab-dd23-4d60-83de-dd6a73b90078">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7ce9f59e-0b11-4f3a-aa05-a88e1aa9c1ae">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_77bd714c-3790-436e-8fde-280daf9850b5">D<xref linkend="sect_TID_1410" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a9103603-6261-4637-b46b-fa22134536fe">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_15f776e2-a5af-4ee4-8902-8d861d3932b7">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d25704ea-5734-4683-8a36-210409afacf8"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a87b6e4f-bced-4eb7-85ca-72f7b53d423c">$Measurement = B<xref linkend="sect_CID_7469" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_cd69869a-c47e-497c-9f3e-a7a0ca6b8da3">$Measurement = B<xref linkend="sect_CID_7468" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_378db2d7-b6b1-4bd5-bd55-3ecc1936deb9">$Units = B<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_99508cbb-2bee-4f5b-8816-1d3495eccb3c">$Derivation = B<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_d653b285-fe19-47d0-9b09-d0cec3ff9359">$Method = B<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_237b4895-3ec5-42f6-83d7-ca4b9914ce10">8</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_34b0264b-6367-41ef-9ab3-ac6f73e5a926">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_edd197ad-42e1-4181-b741-9f29a3ca83f8">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_38ae7415-a014-4b38-bba5-90c84f6d89c9">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8276a87d-183b-4ec0-9de3-c5b2ec064c57">D<xref linkend="sect_TID_1411" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e654f7db-b58f-4a0c-be26-9679fe2714ed">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d0a9eb71-ba77-4b3c-92b0-20807066566c">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_637e45d6-6eee-4f3f-9ce5-fb5d384ae031"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a2b0eb06-c798-4882-abec-a2632ac19b44">$Measurement = B<xref linkend="sect_CID_7469" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_231c3544-4cef-4a52-9ee7-b3a9849e1500">$Measurement = B<xref linkend="sect_CID_7468" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_d952336b-31c3-4a64-a013-7ff63702a47c">$Units = B<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_9f14bfcc-5741-4404-9156-21acc26e58d2">$Derivation = B<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_7ad66743-b635-4689-8f59-e97ffa3bde7d">$Method = B<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e00ee47b-e07a-4063-9295-f00b8f902998">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_75af0046-0485-49d9-8863-6ce205f822c6">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aa985cec-610b-4445-b7f1-2ebbab06936b">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_51feb8fa-c5e0-46a7-afcb-b82dc0f31423">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_afa5de9d-884c-4de6-8af3-0f259624c15e">D<xref linkend="sect_TID_1501" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f0cc25ff-0ec1-44cd-a6c4-4ba948d2a1ae">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2c07259d-38bc-4ccd-94bd-f6802ad60bf1">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_87d9dd51-a193-4405-b81d-59c4610661d1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_17c5d93d-3fbc-4a4b-9dc6-71a477409861">$Measurement = B<xref linkend="sect_CID_7469" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_c1327c1d-3e7c-4cdf-b60e-46228371d2e3">$Measurement = B<xref linkend="sect_CID_7468" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_56c17377-8203-49db-abf1-3e609e9ce931">$Units = B<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                        <para xml:id="para_33b0e4c5-3954-4eb8-89c2-efc8fe79d202">$Derivation = B<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                         <para xml:id="para_2b135bc8-4839-49ce-9cf7-18949e1ba320">$Method = B<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>
                         </para>
                         <para>$ImagePurpose = DT <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link></para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f35f1012-6565-4615-94b4-a578329d628c">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8ccf6dc7-6bfa-4c00-a480-e01762c81728">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bddc1cb2-753b-4cfb-afb9-4e7d0a9a5b88">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_20defab9-20a6-4f11-8d8d-5dc3d112bce6">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_41dd250a-8b5b-4dbf-8841-b031757426a3">EV <link linkend="DCM_126011" xrefstyle="select: nopage">(126011, DCM, "Derived Imaging Measurements")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_22a0c72b-ee47-4b01-8193-4fccee14c0f8">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_86f3c834-9d4e-457b-9727-a65324c488fe">C</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_30d76f5b-1438-404c-8012-2bfb78dc0bc3">IF row 6 and 12 are absent</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_87acdb58-5f9a-4c02-b01a-4e3975a65b68"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td>
                        <para xml:id="para_4dbbe995-3b21-4ef6-acc8-f8e82a43c014">11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e19fbf7f-6880-43dc-8a0e-e04dded8b987">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_94f538e7-d77b-45ac-8745-7926463117b8">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6edc5ae3-633e-4b7b-8ed2-8fda35a733bf">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e0869a6-aba4-443b-8a8a-0a9a242b084e">D<xref linkend="sect_TID_1420" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6ebd888e-3d5f-481e-8cc2-d27a627f050c">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2285bebe-5845-45ac-ba0b-e496db27fc79">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8d908f8c-a89b-42f5-82c8-76b4377d81df"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b8f4b122-190c-4172-ab6b-1e3ef7dbf2fd"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e6303ba8-e73d-47e2-b3f3-a8ef763670e2">12</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_46385195-5342-4453-bea9-10a9a5e847c4">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e920f388-7676-4925-95be-ea982490ed11">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_25092981-319c-409c-9dd1-9ea2999ec332">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7c6a4a43-d145-4388-bdef-847876a32127">EV <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0034375" xl:show="new">(C0034375, UMLS, "Qualitative Evaluations")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ab8cbaaf-8524-43e5-b0ce-aa67fde75001">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_bebf19ad-7f8e-4877-a86c-b22e858a021f">C</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1a7df7bb-aa04-4abf-b4b1-d3a796e31a9d">IF row 6 and 10 are absent</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ce6d2583-fcb3-407b-8163-f8af1ee4f1ae"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2ae96bcf-1778-4a2f-8f33-2f300c0db2b0">13</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5d80579d-2158-4e3f-9c06-060995308632">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_65242578-3b90-4010-b8b5-e1105e04fef6">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b0ae5825-e6b1-4dbb-8154-6e53132b2fe5">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_97685e5a-e9cd-47b1-a9ee-c3573027dbb1"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7072bd7f-1dbb-44a9-a126-90f9eb514a70">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_25ba4a6a-6743-441c-bb3f-fe9a38515976">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4cc22382-35ea-4094-b218-49471bb2254a"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_38da5bd9-00b5-44fb-b597-168e198ee097"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a8f1ea39-3c67-465b-a6c0-e5ec9e55e62b">14</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a53b3bf9-cfde-4fbf-b60a-268f596778ec">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ba2a86fd-3a78-4582-a15a-dc5e41d48a6a">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7ccaf0d9-7de6-4a29-abe8-fad1e57f1783">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_365d761d-516b-4a79-a9f1-19553ce85870"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e2921fd2-68c6-4638-bf28-994fd99a0d2b">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c2054dbc-f637-457f-8b1c-ab6c08b8c103">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ec6954c3-d4e2-422d-92bd-d2a4be05f8f6"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e5a385a8-29ef-49cb-9bf6-181e68405efc"/>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_868f2065-cd1a-426f-a9fe-19f831d32718">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c81883d4-3a76-4f4a-8408-9ed9e49c2b75">Rows 6, 10, 12</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8d3926d3-2967-4b80-9371-98b72ca99b65">The conditions require that at least one of the "heading" containers be present, though any of them may be present but empty.</para>
                     </td>
                  </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Row 7</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Planar ROI measurements are those defined on a single plane by a segmentation reference or planar spatial coordinates.</emphasis></emphasis></para>
                       </td>
                   </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Row 8</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Volumetric ROI measurements are those defined on a volume by raster or surface segmentation references or a set of 2D or 3D spatial coordinates.</emphasis></emphasis></para>
                       </td>
                   </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Row 9</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">Generic measurements include those specified on an image as a whole or by unconstrained graphic coordinates. These may be used for such things as whole image scores or quality measures, and for linear distance meaurements, such as for RECIST or WHO tumor treatment response criteria evaluation.</emphasis></emphasis></para>
                       </td>
                   </tr>
                   <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fa575819-a7dc-4043-ad84-1d6ce95c8b7b">Rows 7, 8, 9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5a0d0919-bb63-4e2f-a517-75d44bd1afe1">The baseline context groups defined allow for generic intensity, size and texture measurements, regardless of the geometry of the ROI (e.g., linear distance can be measured on volumes, or volume can be estimated from a linear distance), and being baseline, do not constrain the invoker from using other appropriate concepts specific to the application.</para>
                         <para><emphasis role="bold"><emphasis role="underline">Different measurements of the same real world lesion made using different types of measurements (different templates) can be correlated by a shared value of Tracking Unique Identifer.
                             See also PS3.17 <xref linkend="sect_RRR.5" xrefstyle="select: label quotedtitle"/><!--<olink targetdoc="PS3.17" targetptr="sect_RRR.5" xrefstyle="select: docname label quotedtitle"/>-->.</emphasis></emphasis></para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3e5dd0ff-8e30-48ec-8878-f4820e8e310d">Row 9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_14d2d51c-ea81-4ee8-8690-833d8c7aabac">A Measurement Group is used to contain one or more individual measurements that are invocations of TID 300, consistent with TIDs 1410 and 1411, which both already have Measurement Group containers as their roots.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_82f87e16-acb0-46aa-82f0-768cc05a326c">Rows 12, 13, 14</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_de8abf94-49ad-4bc0-b8e8-2dc451035fca">These Content Items allow encoding a flat list of name-value pairs that are coded questions with coded or text answers, for example, to record categorical observations related to the entire subject of the report rather than specific measurement groups.</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>
        
        <section label="TID 1501" status="3" xml:id="sect_TID_1501">
            <title>Measurement Group</title>
            <para xml:id="para_114cfb65-4682-44de-a13f-c1d06e3dbb6e">...</para>
            <table frame="box" label="TID 1501" rules="all" xml:id="table_TID_1501_Parameters">
               <caption>Parameters</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3aed916a-5ecd-4156-864c-342338106c58">Parameter Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_10711228-3f87-414f-adee-cb3b75652b81">Parameter Usage</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1c2afd5a-18b0-4d81-bc34-ae924d7fb130">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5a5e95a1-bc37-4997-88aa-cf5b64863b8d">...</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_811e1292-2dcb-4c96-9321-abd8782d58d7">$ImagePurpose</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_afa350c7-6c39-4686-9cfd-c9e3bfa3d1e1">Purpose of Reference for an image used as a source of the measurement</para>
                     </td>
                  </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para>...</para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para>...</para>
                       </td>
                   </tr>
               </tbody>
            </table>
            <table frame="box" label="TID 1501" rules="all" xml:id="table_TID_1501">
               <caption>Measurement Group</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6cf3eeee-bde3-41f2-9cd2-d2a7c2fd15de"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a753304a-333e-44a2-b1de-6a357d827b35">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9b361704-3515-44f8-bc8d-8b4c7bbd3bd6">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3f88f263-0608-4fda-9eb2-629f8f00ab90">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_472206d9-066c-4c71-9bbd-2114d729f75b">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8720acfb-54df-451c-b098-dc55f146f6bd">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_789f5c1b-14da-47e9-8b2d-91afa2c9f6ce">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e618c06c-2ed8-4cc8-86d8-570049b0290b">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_50c97dbc-38b3-4780-8666-e80d0e960f39">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1e553294-3b91-4308-9dd5-cab5993fc271">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c32e330b-8290-4360-a024-2bf2bd867a5a"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7999f1a1-e780-4573-be47-540a1718b75b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1b3f4a25-408c-4c4d-8be6-1d600c149895"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1cc549fc-754a-4eaa-a2d3-6291e8750353"> </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fcc4ffad-bb0d-49ad-b7fa-967199743ff2"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b73d3ca3-05ba-48ac-9eab-b2f0e7f0df78"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d35f0bc7-9294-4136-b82c-6d7c23f702b5"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_03be1fcd-9618-44fa-a630-706e645c6bf3"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9d5a36cf-23f5-4c7d-a5d7-7ee4322f1b03">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e58ce1bd-d0ac-448d-9b93-01f903241340">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6177297b-681a-4e6b-b8c7-2881cd7e0ba7">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_262cd8dd-5c62-46dc-9228-61b78178bd26">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4f382802-3d6d-4d33-a37d-5208d882708c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8e58ba2c-c810-4780-b9f5-3f7391d17037">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_680211e9-9f16-46b4-830e-f947d05bb711">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f5faad4f-a65b-4bee-8c06-4b271b8f4559"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f39a1c62-ce64-4943-a3b6-165b144f07e7">$Measurement = $Measurement</para>
                        <para xml:id="para_793d2241-8a62-4744-babe-23d6f78f652a">$Units = $Units</para>
                        <para xml:id="para_92e6f6ab-8253-4199-b880-698e0b3764e8">$ModType = $ModType</para>
                        <para xml:id="para_51b7a3f0-cef1-41be-ac3c-7328c2a23cf5">$ModValue = $ModValue</para>
                        <para xml:id="para_0195d2d8-4704-46aa-847f-888bf183efef">$Method = $Method</para>
                        <para xml:id="para_a598a4cf-16b8-41e9-8da5-e45fee215ba8">$Derivation = $Derivation</para>
                        <para xml:id="para_a520ab94-54af-48bc-94ad-1c0c012b35a8">$TargetSite = $TargetSite</para>
                        <para xml:id="para_9136f165-0728-41a9-846b-3c467174949e">$TargetSiteMod = $TargetSiteMod</para>
                        <para xml:id="para_618a925c-b9aa-4e68-9be9-69035614020c">$Equation = $Equation</para>
                            <para><emphasis role="bold"><emphasis role="underline">$ImagePurpose = $ImagePurpose</emphasis></emphasis></para>
                        <para xml:id="para_d16f9c46-d989-48e8-8655-1fc0d42caced">$RefAuthority = $RefAuthority</para>
                        <para xml:id="para_874803a4-4c0f-45a0-b22b-6ee636108a9d">$RangeAuthority = $RangeAuthority</para>
                        <para xml:id="para_5b19ea79-97de-4f5e-87c4-8a04ddcc3740">$DerivationParameter = $DerivationParameter</para>
                        <para xml:id="para_9b9c9301-94db-4c83-af7d-b1da9193fccf">$DerivationParameterUnits = $DerivationParameterUnits</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">...</td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_67f4a30d-4f88-4719-ae9a-c8d5625d7f62"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_65325706-0d92-4dba-8b41-c608cc87e86e"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2acb5a0d-c545-4a1e-abb4-0913efdf34ca"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d360eea1-f8d6-4f6d-9f53-fc0aa814839c"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1bd12891-64bf-4198-bc36-caeadd08e7eb"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4d77d339-02e3-4ae5-b412-059bb6434e3c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4680e520-4539-4d07-91f9-446e6133607c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_da4cbd66-66b8-4dbf-884d-50a12e848513"/>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Section headings unchanged (for hyperlinks):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="TID 300" status="3" xml:id="sect_TID_300">
            <title>Measurement</title>
        </section>
        <section label="TID 320" status="3" xml:id="sect_TID_320">
            <title>Image or Spatial Coordinates</title>
        </section>
        <section label="TID 1001" status="3" xml:id="sect_TID_1001">
            <title>Observation Context</title>
        </section>
        <section label="TID 1003" status="3" xml:id="sect_TID_1003">
            <title>Person Observer Identifying Attributes</title>
        </section>
        <section label="TID 1204" status="3" xml:id="sect_TID_1204">
            <title>Language of Content Item and Descendants</title>
        </section>
        <section label="TID 1410" status="3" xml:id="sect_TID_1410">
            <title>Planar ROI Measurements</title>
        </section>
        <section label="TID 1411" status="3" xml:id="sect_TID_1411">
            <title>Volumetric ROI Measurements</title>
        </section>
        <section label="TID 1419" status="3" xml:id="sect_TID_1419">
            <title>ROI Measurements</title>
        </section>
        <section label="TID 1420" status="3" xml:id="sect_TID_1420">
            <title>Measurements Derived From Multiple ROI Measurements</title>
        </section>
        <section label="TID 1600" status="3" xml:id="sect_TID_1600">
            <title>Image Library</title>
        </section>
        <section label="TID 4020" status="3" xml:id="sect_TID_4020">
            <title>CAD Image Library Entry</title>
        </section>
        
        <section label="CID 100" status="3" xml:id="sect_CID_100">
            <title>Quantitative Diagnostic Imaging Procedures</title>
        </section>
        <section label="CID 6147" status="3" xml:id="sect_CID_6147">
            <title>Response Criteria</title>
        </section>
        <section label="CID 7021" status="3" xml:id="sect_CID_7021">
            <title>Measurement Report Document Titles</title>
        </section>
        <section label="CID 7181" status="3" xml:id="sect_CID_7181">
            <title>Abstract Multi-dimensional Image Model Component Units</title>
        </section>
        <section label="CID 7464" status="3" xml:id="sect_CID_7464">
            <title>General Region of Interest Measurement Modifiers</title>
        </section>
        <section label="CID 7468" status="3" xml:id="sect_CID_7468">
            <title>Texture Measurements</title>
        </section>
        <section label="CID 7469" status="3" xml:id="sect_CID_7469">
            <title>Generic Intensity and Size Measurements</title>
        </section>
        <section label="CID 7470" status="3" xml:id="sect_CID_7470">
            <title>Linear Measurements</title>
        </section>
        <section label="CID 7474" status="3" xml:id="sect_CID_7474">
            <title>General Volume Calculation Methods</title>
        </section>
      
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.17 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="RRR" status="1" xml:id="chapter_RRR">
    <title>Measurement Report SR Document for Planar and Volumetric ROI (Informative)</title>
    <para xml:id="para_82cd817a-55dd-4b3c-8e24-d8f91de07f35">....</para>

    <section label="RRR.2" status="2" xml:id="sect_RRR.2">
      <title>Measurement Report SR Document Volumetric ROI on CT Example</title>
      <para xml:id="para_a752356d-54db-4780-8e15-b0c58b7f5762">This CT example describes a set of measurements (volume. long axis and mean attenuation coefficient) made from a single volumetric ROI encoded as a single segment that spans two source CT images, and includes a description of the measurement methods and the finding site, as well as an image library to describe characteristics of the images used, and categorical observations at the measurement group and entire subject level.</para>
      <note>
        <orderedlist>
          <listitem>
            <para xml:id="para_2e5046df-14d3-4125-bff6-a07188a2bb40">For a different modality than CT, the choice of measurement for the mean intensity would not be <olink targetdoc="PS3.16" targetptr="DCM_122713">(122713, DCM, "Attenuation Coefficient")</olink>.</para>
          </listitem>
          <listitem>
            <para xml:id="para_24c62e9f-f175-44a7-a598-d1bcf3d89925">For MR one might use <olink targetdoc="PS3.16" targetptr="DCM_110852">(110852, DCM, "MR signal intensity")</olink>, or <olink targetdoc="PS3.16" targetptr="DCM_110804">(110804, DCM, "T1 Weighted MR Signal Intensity")</olink>, etc. See also <olink targetdoc="PS3.16" targetptr="sect_CID_7180" xrefstyle="select: labelnumber quotedtitle"/> for various appropriate signal intensity types for MR and other modalities.</para>
          </listitem>
          <listitem>
            <para xml:id="para_5ab71f19-45d5-42ee-9e8f-43601942495a">For PET one might use <olink targetdoc="PS3.16" targetptr="DCM_110821">(110821, DCM, "Nuclear Medicine Tomographic Activity")</olink>, in which case the specific type of signal would be apparent from the units, e.g., ({SUVbw}g/ml, UCUM, "Standardized Uptake Value body weight") or for activity-concentration, (Bq/ml, UCUM, "Becquerels/milliliter"). See also <olink targetdoc="PS3.16" targetptr="sect_CID_84" xrefstyle="select: labelnumber quotedtitle"/>.</para>
          </listitem>
          <listitem>
            <para xml:id="para_2f899334-fe4f-41ad-8309-953df6df627e">Care should be taken when selecting modifiers such as <link xl:href="http://snomed.info/id/370129005" xl:show="new">(G-C036, SRT, "Measurement Method")</link> versus <olink targetdoc="PS3.16" targetptr="DCM_121401">(121401, DCM, "Derivation")</olink>.</para>
          </listitem>
          <listitem>
            <para xml:id="para_6a0b3e61-eacc-4e28-aa4d-89bf069a749a">The finding site and laterality within the measurement template (<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber quotedtitle"/>) are factored out and shared by both measurements.</para>
          </listitem>
          <listitem>
                            <para xml:id="para_8a7dd91c-d2ea-455e-bd19-ae338792e6f6">The pattern used for the image library uses <olink targetdoc="PS3.16" targetptr="sect_TID_4020" xrefstyle="select: labelnumber quotedtitle"/>, though commonality may be refactored.</para>
                        </listitem>
                        <listitem>
                            <para><emphasis role="bold"><emphasis role="underline">The long axis of the volumetric ROI is encoded, but the end points of the line segment used to make that measurement are not recorded, since only the volumetric spatial description of TID 1411 is used. For an alternative encoding, see <xref linkend="sect_RRR.5" xrefstyle="select: label"/>.</emphasis></emphasis></para>
                        </listitem>
        </orderedlist>
      </note>
      <table frame="box" label="RRR.2-1" rules="all" xml:id="table_RRR.2-1">
        <caption>Volumetric ROI on CT Example</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_361be96c-7681-4796-a596-206a9d775416">Node</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_c8529632-7670-4294-b01f-8f08ca0b43cc">Code Meaning of Concept Name</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_0679f5ef-19b4-4117-b643-b1c934e742e5">Code Meaning or Example Value</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_a860b330-c1d4-4309-9e29-5d90ece77d18">TID</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_6f40f2d8-f565-4188-9449-270261bf3a8a">1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_6c3eb34a-c187-41a2-b704-ed82451afcdd">Oncology Measurement Report</para>
            </td>
            <td align="left" colspan="1" rowspan="1"/>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_225694ec-7b0c-4cea-b29a-07132ee9b62c">
                <xref linkend="sect_TID_1500" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1500" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_8313fba6-f1d6-4099-bc15-9f8934286b64">1.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_069be704-464f-4ba2-b540-600ee849e1e5">Language of Content Item and Descendants</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_fd091bb5-3876-4d5c-a7b3-f5b96c973e64">English</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_bd606988-4869-49cf-aad8-667880e9f927">
                <xref linkend="sect_TID_1204" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1204" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_28b02d01-8505-4c5e-874f-c134c79cd174">
                <emphasis role="bold">1.2</emphasis>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c6da9fa4-a6f7-4219-a536-05c713f6b0c9">Observation Context</para>
            </td>
            <td align="left" colspan="1" rowspan="1"/>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_4e0431d3-d7b1-4348-a965-9e0e52662671">
                <xref linkend="sect_TID_1001" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1001" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5ee17831-0a88-415a-8c99-fbe94bd08c44">1.2.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_ab41d028-f562-4d79-adaa-4813388f4e13">Person Observer Name</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b1024c77-8fee-410a-b44b-db8432faeef7">Doe^Jane</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_4de9de60-b1a3-4190-b82d-f0da4268abc4">
                <xref linkend="sect_TID_1003" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1003" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_3eb3cd0a-c201-4319-aeaa-d16f03aa2da4">1.3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_3515e994-7192-4bb8-8943-d3fb40b1168e">Procedure Reported</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_7ce59317-ab24-4438-a5c0-68eb8c5b98f6">Chest+Abd CT W+WO contr IV</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_0f45005d-694c-4bb2-9aa6-7b4a4f47660c">
                <xref linkend="sect_TID_1500" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1500" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_1b6df1b0-147a-4b20-8281-15c4a282f70b">1.4</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_cb1bb332-92bd-4ebc-a37c-2805232e701a">Image Library</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_749c7151-21ee-409a-aa3e-3560d84b2eba"/>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_dd8747fc-a5a4-4d23-8a41-3cbb310859d3">
                <xref linkend="sect_TID_1500" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1500" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_a50ca922-d981-4116-845d-aec15d131927">1.4.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1"/>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_91af65bf-4efa-4648-a092-3e747f83f780">IMAGE - CT image #1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_a59c609a-f0ff-4da5-99a0-8f7c6b98104a">
                <xref linkend="sect_TID_4020" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_4020" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_fb519b32-3d97-4fb7-a76f-0138bc3110cc">1.4.1.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_3feb467e-ecd3-459f-a781-5a1097b19d12">Study Date</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_867eb421-ac7b-4512-ba39-64e70f5d0149">20030417</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_6a19b3cf-c853-415f-9552-359baeca3997">
                <xref linkend="sect_TID_4020" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_4020" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_bc63486d-e421-4667-a173-113f84aec7a8">1.4.1.2</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_dfde14c1-e973-4848-9bea-d32d5cc702fe">Study Time</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_33e105d5-4647-43a5-9015-fc906d8bed9b">104607</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_37b98754-03ad-4034-ac39-a1dbc7a7b2fa">
                <xref linkend="sect_TID_4020" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_4020" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_838923b4-a269-4c0f-ab7d-27d4437831c0">1.4.1.3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_f79cc7c7-03a6-4abe-bf58-81bb36058f63">Horizontal Pixel Spacing</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_9a579c1f-07a3-431a-aeff-03575bfed925">0.810547 mm</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b8b33b07-062a-49d3-b549-766250982a03">
                <xref linkend="sect_TID_4020" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_4020" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c98b768c-7af5-4dae-9c83-be8a9c32a775">1.4.1.j</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c749dc96-e740-4f23-b28f-20e4b6707a78">...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_061ec9cf-5a9b-49bd-a0bc-1c5735e69184">...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b2d834e7-3f37-467d-82c0-fb5c9ed90008">
                <xref linkend="sect_TID_4020" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_4020" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_1839ec42-1d1d-490e-9c7e-9388183267d5">1.4.1.n</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b9cbe0f0-4f36-4675-a776-32a64b714ebf">Pixel Data Columns</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_35d0764c-713c-4878-bfd2-f7353721cb3c">512 pixels</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_ed847e9b-86a9-4515-89dd-c583ad2cf009">
                <xref linkend="sect_TID_4020" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_4020" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_dfa251ab-e1d7-4c2e-9342-8153ca6af528">1.4.2</para>
            </td>
            <td align="left" colspan="1" rowspan="1"/>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_cb8d3589-9974-4ede-b667-90f92b389ea0">IMAGE - CT image #2</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_9d69da55-5ebb-499f-be04-5cd1683344ac">
                <xref linkend="sect_TID_4020" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_4020" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_9e65d974-718d-4851-8b06-c28d3b3ad1d3">1.4.2.j</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5ea0b0f5-4260-4a41-a658-4f3b8ddee5a5">...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_3e156c3d-0a88-4113-9f49-7f93f11ecc58">...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_d3b4619a-dee4-4454-967b-b93f324a5dec">
                <xref linkend="sect_TID_4020" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_4020" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_cf62b723-752c-4f0b-85a2-a9c29e01c145">1.5</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_e8cf3189-bd71-42c6-ade4-2aaab4eb835c">Measurements</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_1f62ece6-d1c9-40c7-b541-aaca830cee31"/>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c802a929-0a40-450b-b211-2b00c2609fbd">
                <xref linkend="sect_TID_1500" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1500" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_860660f8-67d6-4077-8f0f-e456d6034365">1.5.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_d87e8b28-4612-4ed1-b83f-48214b28dff6">Measurement Group</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_bbfd3caa-bfea-4ee9-b51e-6f6f99bc0077"/>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_95c4702f-ad2c-4fb5-a869-cc1c4fbdd89b">
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b42a14c7-e1be-47df-ad39-833e17c8d98e">1.5.1.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_e9f67fbd-980a-477e-979e-81a6e98fa72c">Tracking Identifier</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_dd5f3c03-f85d-43f6-bf08-4af40ad80126">Object1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_bd60b4c5-57b7-458c-8846-829b43f72c31">
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_9371dea4-6014-47ab-88c9-c047d62ee956">1.5.1.2</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_dcb4eb00-5484-404d-b884-af2c7c155684">Tracking Unique Identifier</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_4a923f00-f22e-469b-b615-ae5f762ef60e">1.2.276.0.7230010...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_a65283e6-8ab8-45f9-988d-1143ac7e342e">
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_7b790b63-979f-4785-95b4-9247de0a78fc">1.5.1.3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_4e86a610-272e-477d-acf7-6553b834b43c">Referenced Segment</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_db69a6db-727a-4b4b-acce-0f650adb23cc">IMAGE - Segmentation, Segment #1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_2bb30e80-c515-4ae0-9afc-382a59c7f651">
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_e5576657-7e50-4a75-b51e-a92039ec09bb">1.5.1.4</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_981a551a-f21e-4607-b857-962921538cee">Source image for segmentation</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5f158e36-231d-4297-a90b-878a20944336">IMAGE - CT image #1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_92d91d86-8b46-4036-9e71-7d28a78a5494">
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_099ab86a-3ddf-48d3-9144-eae8fa10d998">1.5.1.5</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_6309762c-9e0f-4ef9-a2f6-86313ac8b239">Source image for segmentation</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_f2b45bcd-9226-49f2-8ef1-c11aff12de66">IMAGE - CT image #2</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_af76337c-c79d-4ea9-9222-62d584fa5838">
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_524fced2-2545-4835-963c-944d2594b42b">1.5.1.6</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_dc697e6d-1805-497a-99b6-b9886c878b2a">Finding Site</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_a24450e2-02ac-498f-9b76-dfd08b3a0284">Adrenal Gland</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_4e38b353-4dd5-449b-89a1-5664ca338409">
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_16b0891f-52df-4e37-9ef7-6f300f6f13c6">1.5.1.6.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_05e08e16-4167-4112-8dd1-79d6a1ec4b0b">Laterality</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_bbb358c3-3098-4683-bb28-315e947214f2">Right</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_4354034a-22c7-41ce-b5f8-461cb27f5b45">
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_62c73c25-46f4-483c-a234-f86edda07d8b">1.5.1.7</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_0cb4d579-d90b-47fe-a9dd-dd3d1c908871">Volume</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_2736b3ef-d6b0-4f0a-8a7f-76c3875c7bbc">3267.46 mm3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_609578d7-ffc8-480f-a238-8a34a31ee1ef">
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b7acb01a-a035-4b4b-a01a-5efd4c6ff4e9">1.5.1.7.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5ccf1d04-1f48-4255-b27c-8327220e3b15">Measurement Method</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_93df8402-a3e6-4fad-b0e9-6f27aafd6e5a">Sum of segmented voxel volumes</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c35d6b97-ac12-4df1-aba1-8024ae92709b">
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
              <para xml:id="para_16227f28-fa33-4875-8942-51c3b21feac9">
                <xref linkend="sect_CID_7474" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7474" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>

          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_15c65243-f0db-470f-b502-ec1b5ef80599">1.5.1.8</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_1dd6e2e7-eeb8-4e7f-8bdc-1bf9573dcec1">Long Axis</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c568aa31-5845-4369-babb-b4976ff159c2">9.21 mm</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_2b6b0ca8-04d8-418d-b2cc-99ca19260660">
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
              <para xml:id="para_2670a521-ca5c-41b6-944b-e09429cb2b0c">
                <xref linkend="sect_CID_7470" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7470" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_853a3c7e-170b-43b6-a806-d6d052a19164">1.5.1.8.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5b8a5c9e-2add-46b9-8bb2-52f9a6cdb5a9">Measurement Method</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c92d448a-3f77-4f95-804f-231caafab9d9">RECIST 1.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5e89cb3a-84a8-4c8a-8ba9-993c215ebe3a">
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
              <para xml:id="para_a2d4149c-03bd-4f92-adb4-41412ae74882">
                <xref linkend="sect_CID_6147" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_6147" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>



          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_7ceec745-e99a-41ea-9e26-d955e35d2102">1.5.1.9</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_080501ef-3f04-4509-931f-2ba09f4f1146">Attenuation Coefficient</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_029d3f9f-c162-4493-8acb-7fcce090ecf1">70.978 Hounsfield unit</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_9e01dd2b-c703-4aa8-87c6-53eb1841262b">
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_309d9268-894d-4c04-8011-013ad6cb6b60">1.5.1.9.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_914d756f-7cf2-4dce-bfeb-09cc3ab47442">Derivation</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_22c6a12f-0c8d-4942-bf2f-a00d52aacc5f">Mean</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_70dd6c23-b900-466e-a0c7-ce3e74f5290e">
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
              <para xml:id="para_8df9cd8e-b6bf-4071-abf8-4d1dae10a4e7">
                <xref linkend="sect_CID_7464" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7464" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_1b021db3-335a-4efc-95a6-c4fad5cf70a3">1.5.1.10</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b8c9d041-f2f7-4b49-8bb9-745ccc9545d4">Necrosis</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_18a2e93e-744a-4ed0-92b6-c6db69c6241f">Present</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5dbe8d2e-066b-49dc-8593-5ca3b55c4e3d">
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c57e9b35-9514-4073-8f12-cd8b24c013e8">1.5.1.11</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_308643ba-c763-415f-8fb5-fa20f5d2cccb">Hemorrhage</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_f13ff9ed-8d25-4ad4-95d6-7c3559804a6c">Absent</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_7556e4fb-e45a-452f-ac3d-ace1d9722a0f">
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_76e04a3c-ee63-4495-a55c-8ff687b87e53">1.6</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_472ffa5b-5524-4b7f-a101-3b3dd3883809">Qualitative Evaluations</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_e9a88628-c8ee-4ff6-9c97-a3630b5d86d7"/>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c3089b2e-44c1-48f3-b0ca-1ea0ed44a959">
                <xref linkend="sect_TID_1500" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1500" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_910a0932-15b8-4e26-b6b0-cc28a827e3fb">1.6.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c041a4af-4658-4075-9174-fd0b151eca6c">Renal Vein Involvement</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_4f141053-eb64-473c-932b-260a3a769dbe">Absent</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b24914e0-fc72-4600-b385-e61d5f2dd596">
                <xref linkend="sect_TID_1500" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1500" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
        </tbody>
      </table>

    </section>
            
            <informaltable rules="all" frame="box">
                <tr>
                    <td>
                        <para><emphasis role="italic">Add new Section to DICOM PS3.17 as follows :</emphasis></para>
                    </td>
                </tr>
            </informaltable>
            
            <section label="RRR.5" status="2" xml:id="sect_RRR.5">
      <title>Measurement Report SR Document Volumetric ROI with RECIST Linear Distance Specified by Coordinates on CT Example</title>
      <para>This CT example describes a set of measurements (volume, long axis (RECIST) and mean attenuation coefficient) made from a single volumetric ROI encoded as a single segment, including specification of the end points of the line segment used to make the linear distance measurement.</para>
      <note>
        <orderedlist>
                        <listitem>
                            <para>The long axis of the lesion is not encoded as a characteristic of the volumetric ROI, but rather as the end points of a line segment used to make that measurement. The commonality of the Tracking Unique Identifier establishes that they are measurements of the same ROI. If multiple measurements were to be made of the same ROI over time or by different observers, other content items such as those related to Timepoint, Activity Session and Observer may be used. For an alternative encoding, see <xref linkend="sect_RRR.2" xrefstyle="select: label"/>.</para>
                        </listitem>
                        <listitem>
                            <para>The Finding Site information is duplicated in the second measurement template invocation in this example, though it is not require to be.</para>
                        </listitem>
        </orderedlist>
      </note>
      <table frame="box" label="RRR.5-1" rules="all" xml:id="table_RRR.5-1">
        <caption>Volumetric ROI on CT Example</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>Node</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>Code Meaning of Concept Name</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>Code Meaning or Example Value</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>TID</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Oncology Measurement Report</para>
            </td>
            <td align="left" colspan="1" rowspan="1"/>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1500" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1500" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_4020" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_4020" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Measurements</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para/>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1500" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1500" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Measurement Group</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para/>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Tracking Identifier</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Object1 (same for both Measurement Groups)</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.2</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Tracking Unique Identifier</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>1.2.276.0.7230010... (same for both Measurement Groups)</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Referenced Segment</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>IMAGE - Segmentation, Segment #1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.4</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Source image for segmentation</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>IMAGE - CT image #1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.5</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Source image for segmentation</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>IMAGE - CT image #2</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1411" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1411" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.6</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Finding Site</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Adrenal Gland (same for both Measurement Groups)</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.6.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Laterality</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Right (same for both Measurement Groups)</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.7</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Volume</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>3267.46 mm3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.7.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Measurement Method</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Sum of segmented voxel volumes</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
              <para>
                <xref linkend="sect_CID_7474" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7474" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>



          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.8</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Attenuation Coefficient</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>70.978 Hounsfield unit</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>1.5.1.8.1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Derivation</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Mean</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_TID_1419" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1419" xrefstyle="select: labelnumber"/>-->
              </para>
              <para>
                <xref linkend="sect_CID_7464" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7464" xrefstyle="select: labelnumber"/>-->
              </para>
            </td>
          </tr>
            
            
            
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para>1.6.1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Measurement Group</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para/>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>
                        <xref linkend="sect_TID_1501" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1501" xrefstyle="select: labelnumber"/>-->
                    </para>
                </td>
            </tr>
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para>1.6.1.1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Tracking Identifier</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Object1 (same for both Measurement Groups)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>
                        <xref linkend="sect_TID_1501" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1501" xrefstyle="select: labelnumber"/>-->
                    </para>
                </td>
            </tr>
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para>1.6.1.2</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Tracking Unique Identifier</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>1.2.276.0.7230010... (same for both Measurement Groups)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>
                        <xref linkend="sect_TID_1501" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1501" xrefstyle="select: labelnumber"/>-->
                    </para>
                </td>
            </tr>
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para>1.6.1.3</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Finding Site</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Adrenal Gland (same for both Measurement Groups)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>
                        <xref linkend="sect_TID_1501" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1501" xrefstyle="select: labelnumber"/>-->
                    </para>
                </td>
            </tr>
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para>1.6.1.3.1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Laterality</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Right (same for both Measurement Groups)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>
                        <xref linkend="sect_TID_1501" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_1501" xrefstyle="select: labelnumber"/>-->
                    </para>
                </td>
            </tr>
            
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para>1.6.1.4</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Long Axis</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>9.21 mm</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>
                        <xref linkend="sect_TID_300" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_300" xrefstyle="select: labelnumber"/>-->
                    </para>
                    <para>
                        <xref linkend="sect_CID_7470" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7470" xrefstyle="select: labelnumber"/>-->
                    </para>
                </td>
            </tr>
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para>1.6.1.4.1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Measurement Method</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>RECIST 1.1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>
                        <xref linkend="sect_TID_300" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_300" xrefstyle="select: labelnumber"/>-->
                    </para>
                    <para>
                        <xref linkend="sect_CID_6147" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_6147" xrefstyle="select: labelnumber"/>-->
                    </para>
                </td>
            </tr>
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para>1.6.1.5</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>Source of Measurement</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>SCOORD GraphicType POLYLINE with two coordinates, the beginning and end of a line segment</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>
                        <xref linkend="sect_TID_320" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_320" xrefstyle="select: labelnumber"/>-->
                    </para>
                    <para>
                        <xref linkend="sect_CID_7470" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7470" xrefstyle="select: labelnumber"/>-->
                    </para>
                </td>
            </tr>
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para>1.6.1.5.1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>(none)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>IMAGE - CT image #1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para>
                        <xref linkend="sect_TID_320" xrefstyle="select: labelnumber"/><!--<olink targetdoc="PS3.16" targetptr="sect_TID_320" xrefstyle="select: labelnumber"/>-->
                    </para>
                </td>
            </tr>        </tbody>
      </table>

    </section>
  </section>
    </chapter>
</book>