<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1816</title>
    <subtitle>Update JPEG-LS and RLE Media Types for web services to use registered rather than experimental media types</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/06/04</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                 xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/04/04</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1816</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Update JPEG-LS and RLE Media Types for web services to use registered rather than experimental media types</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.18</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>IANA has accepted registrations for JPEG-LS and DICOM RLE , so experimental media types hould be replaced.</para>
                    <para>See:</para>
                    <itemizedlist>
                        <listitem>
                            <para><link xl:href="http://www.iana.org/assignments/media-types/image/jls"/></para>
                        </listitem>
                        <listitem>
                            <para><link xl:href="http://www.iana.org/assignments/media-types/image/dicom-rle"/></para>
                        </listitem>
                        
                    </itemizedlist>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.18 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="6.1.1.8" status="4" xml:id="sect_6.1.1.8">
            <title>DICOM Media Types and Media Types For Bulk Data</title>
        <table frame="box" label="6.1.1.8-3b" rules="all" xml:id="table_6.1.1.8-3b">
            <caption>Media Types and Transfer Syntax UIDs for Compressed Pixel Data in Bulk Data Values</caption>
            <thead>
              <tr valign="top">
                <th align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5cb4bde1-16aa-4131-8b7a-5c02c785a92c">Category</para>
                </th>
                <th align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1b3b281a-4dc1-4bbc-954f-9473564a0dce">MediaType</para>
                </th>
                <th align="left" colspan="1" rowspan="1">
                  <para xml:id="para_7d5e66a1-068e-4145-bb80-537475ec45cf">Transfer SyntaxUID</para>
                </th>
                <th align="left" colspan="1" rowspan="1">
                  <para xml:id="para_db97d263-6d8d-460e-b881-b2b206454753">Transfer Syntax Name</para>
                </th>
                <th align="left" colspan="1" rowspan="1">
                  <para xml:id="para_bd45a8d3-256f-4ee0-9be9-062786bdb967">RS</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="11">
                  <para xml:id="para_5ec23508-a9aa-4ed7-b692-ac599731f9f9">Single Frame Image</para>
                </td>
                <td align="left" colspan="1" rowspan="4">
                  <para xml:id="para_073c7d11-eb71-4da3-bdee-eaf465802189">image/jpeg</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_16674eeb-31d1-453d-8858-750de994d755">1.2.840.10008.1.2.4.70</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_caf1a0d9-7cc1-4d79-b5c5-b9310b4758b5">JPEG Lossless, Non-Hierarchical, First-Order Prediction(Process 14 [Selection Value 1]) :Default Transfer Syntax for Lossless JPEG Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_39918a15-b7ee-4fdd-b65b-963bbc29f989">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f44278bd-9530-4a1c-9f8e-0b3c6cc6f79b">1.2.840.10008.1.2.4.50</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f2820e44-6e61-426b-871f-c204d229f1d2">JPEG Baseline (Process 1) :Default Transfer Syntax for Lossy JPEG 8 Bit Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c7682496-3af1-40bf-acb8-2c0ede0fe4ba">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_95a1f1c2-98d1-443a-b1bf-ca5ddcad0921">1.2.840.10008.1.2.4.51</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5192b498-bb01-43e2-8ebf-e09db452dd8e">JPEG Extended (Process 2 &amp; 4) :Default Transfer Syntax for Lossy JPEG 12 Bit Image Compression (Process 4 only)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_958f516f-7edb-4a1b-99ef-d148662c3d4a">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_51aa8b5f-699d-4438-a7bf-c4df26d7028b">1.2.840.10008.1.2.4.57</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_978e0081-e2e4-48f0-a70d-c7d3acb144b4">JPEG Lossless, Non-Hierarchical (Process 14)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_02837648-381f-40d5-add2-e82d0fa7beb6">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_24036d8d-7a69-4ae0-9a18-27d2bcc11445">image/<emphasis role="bold"><emphasis role="strikethrough">x-</emphasis></emphasis>dicom-rle</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c882e85b-4eef-4e70-b9bf-f92fe0c25e71">1.2.840.10008.1.2.5</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_cb83ac9d-e91d-4020-933d-932c3c72947c">RLE Lossless</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d7e82630-3215-47fc-9905-270312d943bd">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="2">
                  <para xml:id="para_cec06431-19c7-4975-8eb3-1702ed0e5707">image/<emphasis role="bold"><emphasis role="strikethrough">x-</emphasis></emphasis>jls</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_38cfe13b-dcff-458d-a813-1d205814d3e2">1.2.840.10008.1.2.4.80</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5293845a-dd8c-4c86-9a88-6271a4795d15">JPEG-LS Lossless Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_42a2e646-23d0-4d9e-ab05-78fbd64e03ca">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ee62c2f7-b0de-4a30-86d4-ec37d248fd81">1.2.840.10008.1.2.4.81</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_002facf5-b7e6-4190-8ed1-1cd95c039e9e">JPEG-LS Lossy (Near-Lossless) Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_776e8a3d-2773-4d1b-819b-df70c07f0252">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="2">
                  <para xml:id="para_ba0eb378-b699-4996-b242-c5bf47e82a5e">image/jp2</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_57f0ac95-3d03-4efa-8273-81a38f536244">1.2.840.10008.1.2.4.90</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_62399cd0-9e2c-4cfd-a736-3b6fd6c037d7">JPEG 2000 Image Compression (Lossless Only)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6c62a0af-1ec4-4f89-86ad-0e75739fba72">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_7d1532ba-a1d1-4151-ab34-11a94f313c66">1.2.840.10008.1.2.4.91</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_685a2521-b993-4128-9a93-5f54542a7df5">JPEG 2000 Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d22a467c-3d86-4787-a51f-6771af34b8f6">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="2">
                  <para xml:id="para_7da12159-5476-4adc-b3e5-7257ed1b9efa">image/jpx</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_61a30cbc-a53d-45e6-ad75-de94baf5f07d">1.2.840.10008.1.2.4.92</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5f008c2a-9081-4ea1-ba37-9abb970c41aa">JPEG 2000 Part 2 Multi-component Image Compression (Lossless Only)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ef4a2f69-533b-44a7-8bc1-2ab1fe33ad22">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6f37e3f8-3147-4efe-82ee-2a1a9b7e6cfb">1.2.840.10008.1.2.4.93</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ca487fdb-feb4-42f1-bc07-e7f5110ee2d9">JPEG 2000 Part 2 Multi-component Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_18ee8ec4-a674-4ab6-ad17-81c9b06038cf">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="11">
                  <para xml:id="para_309f0fc8-7861-4ca7-8f73-89c9dfaa94ab">Multi-frame Image</para>
                </td>
                <td align="left" colspan="1" rowspan="4">
                  <para xml:id="para_453cf8ec-0afb-41f5-a50a-b9a9cb2247c9">image/jpeg</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_083ded66-519e-4e64-8c2f-69f2d8a5de33">1.2.840.10008.1.2.4.70</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_bacd43a0-7818-4015-80dd-4f0db226690b">JPEG Lossless, Non-Hierarchical, First-Order Prediction(Process 14 [Selection Value 1]) :Default Transfer Syntax for Lossless JPEG Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_7c493193-6f22-4d4e-9992-f52227a4b365">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_cb3edb2f-e5bb-41e3-b1fa-5fa992ec2550">1.2.840.10008.1.2.4.50</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_52426789-dc4b-4f9f-86c7-7004a258222b">JPEG Baseline (Process 1) :Default Transfer Syntax for Lossy JPEG 8 Bit Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_79fb1d08-51f1-4831-b3de-2915c19f5932">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_805f5459-d2ad-4176-a59f-5b7f71330f99">1.2.840.10008.1.2.4.51</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_46a87126-ccb4-4ee9-b928-5cd352d2536a">JPEG Extended (Process 2 &amp; 4) :Default Transfer Syntax for Lossy JPEG 12 Bit Image Compression (Process 4 only)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_b1e92a8d-3438-4927-8ee4-d23debca0aea">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_30054ac4-900c-431e-8295-2785bbd3b6b4">1.2.840.10008.1.2.4.57</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a6db4dc1-89f8-4e15-ba24-d6119e495765">JPEG Lossless, Non-Hierarchical (Process 14)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1cb86759-bdee-4ae8-9e9c-c7567e70614c">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_c4dda872-91ce-4a0c-aae4-d0035cfa624c">image/<emphasis role="bold"><emphasis role="strikethrough">x-</emphasis></emphasis>dicom-rle</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c0d5010a-8de3-4499-9422-8498d8815716">1.2.840.10008.1.2.5</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_60bb0e39-03bd-474d-951d-e571db578c4c">RLE Lossless</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_299f3885-0eed-4d1d-aa96-afe8aa0e9e2c">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="2">
                    <para xml:id="para_d26b9d20-e151-484d-8327-ce64a0af5a46">image/<emphasis role="bold"><emphasis role="strikethrough">x-</emphasis></emphasis>jls</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6de11db1-8319-482f-ba61-097b0a40a851">1.2.840.10008.1.2.4.80</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_127aa87d-08cd-4087-ae1a-2c99b360f6a1">JPEG-LS Lossless Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_21a080d9-cf0e-46ad-8335-56141f7faac4">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_851b8454-c477-4035-863d-b8ff8379679c">1.2.840.10008.1.2.4.81</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8e565a19-8f5c-4165-bb4c-a58dc31c6800">JPEG-LS Lossy (Near-Lossless) Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6b0d3aa0-1767-4cf3-9129-0753b88b2a50">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="2">
                  <para xml:id="para_d8226097-1794-46e1-bbbe-245ec158a4f5">image/jp2</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8333a12e-f993-46b7-a7d0-13e3bc3c9609">1.2.840.10008.1.2.4.90</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_b112975d-6e0a-45d0-ad61-9a51cd37407d">JPEG 2000 Image Compression (Lossless Only)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_06988e68-0643-4a2b-bfb1-5812327b5b16">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1f1b6ddc-2ffe-4fa7-b0a4-4114b939b77e">1.2.840.10008.1.2.4.91</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_b8c5cbf7-47db-4082-9f14-1a5b8b9efe85">JPEG 2000 Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_04206f64-0a29-4cac-921f-943cbbc64b65">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="2">
                  <para xml:id="para_9b872cf5-59e5-45ca-acb9-08b64d8b16d4">image/jpx</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ae019047-5907-45da-b29c-3fe290f58cd4">1.2.840.10008.1.2.4.92</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_20ae2042-25c5-4d12-8465-d637d7ac8beb">JPEG 2000 Part 2 Multi-component Image Compression (Lossless Only)</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_3810e9df-731e-4a4f-884b-cb40e71f0887">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_918c2be4-d10a-490b-9354-e40fe414dedc">1.2.840.10008.1.2.4.93</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e49e5d1c-ca8e-48e3-a153-a90584d78105">JPEG 2000 Part 2 Multi-component Image Compression</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ec77d043-6108-4e6f-b811-5a57899e53ef">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="7">
                  <para xml:id="para_e5895e0b-1de8-4510-b8c6-99abe6e26538">Video</para>
                </td>
                <td align="left" colspan="1" rowspan="2">
                  <para xml:id="para_599acef8-c1cf-44a2-838e-09615a676aba">video/mpeg2</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_aa49a952-24db-446a-9bbe-ded9eb23396d">1.2.840.10008.1.2.4.100</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_dc80a636-ff9c-410a-8a9f-d5bdfef2c2b3">MPEG2 Main Profile / Main Level</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8d203c97-6bd9-48f2-ac4e-fc68b8dfc678">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d9532f0b-b40e-4222-b1b8-95085669a7a2">1.2.840.10008.1.2.4.101</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8d72febe-a3ea-46d3-ae92-e64a1bb226ed">MPEG2 Main Profile / High Level</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_357bae24-e5db-4f11-9444-0a53dd8e4a25">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="5">
                  <para xml:id="para_af731abe-0ade-4f95-919c-52279d9bf36a">video/mp4</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_34d27fa8-bf8f-4c37-bb41-5fb8bbc9f653">1.2.840.10008.1.2.4.102</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8da36f62-b697-4885-9d24-7ab3ee2c3166">MPEG-4 AVC/H.264 High Profile / Level 4.1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9abd07a7-565b-445d-914a-342e47ec70be">default</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_cb628313-a392-4ab1-b7a5-223bd97af377">1.2.840.10008.1.2.4.103</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0b0cd0eb-1a68-4a2e-a787-6f34469ef88c">MPEG-4 AVC/H.264 BD-compatible High Profile / Level 4.1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_521c8a41-7d7b-406b-8725-0a33f334b18c">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_fe45b4eb-3fe4-4220-a928-28ee342e76d0">1.2.840.10008.1.2.4.104</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_96fca975-1013-4fd6-8a16-400be48dd799">MPEG-4 AVC/H.264 High Profile / Level 4.2 For 2D Video</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_30ce0a25-57a5-4f4c-9739-72905a5d5e6b">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_31f410da-1cfe-4197-a065-d4a1dd4395bb">1.2.840.10008.1.2.4.105</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_3209b72c-a963-4791-9372-1ae2cae6bee4">MPEG-4 AVC/H.264 High Profile / Level 4.2 For 3D Video</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a31a0cf0-4c40-4632-a3dd-3c80034d5ff4">optional</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_cc938b59-d019-4314-9dfa-73d875387399">1.2.840.10008.1.2.4.106</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6dbcfd04-3dd2-4e8f-be5c-8b4b874a3bcd">MPEG-4 AVC/H.264 Stereo High Profile / Level 4.2</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9e986224-72d2-4cac-ad00-5a8180da860f">optional</para>
                </td>
              </tr>
            </tbody>
          </table>
            <note>
                <para><emphasis role="bold"><emphasis role="underline">Previously, experimental Media Types "image/x-dicom-rle" and "image/x-jls" were defined, so origin servers and user agents may want to account for these when communicating with older implementations.</emphasis></emphasis></para>
            </note>
        </section>
        
    </chapter>
</book>
