<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1790</title>
    <subtitle>Correct relationship of Reconstruction Algorithm in TID 10013 CT Irradiation Event Data </subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/03/25</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Xavier Carayol</para><para><link xl:href="mailto:xavier.carayol@csdental.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/03/08</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1790</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Correct relationship of Reconstruction Algorithm in TID 10013 CT Irradiation Event Data</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para>
                    <para>Only CONTAINER content items may have CONTAINS relationships.</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="strikethrough">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
<section label="TID 10013" status="3" xml:id="sect_TID_10013">
            <title>CT Irradiation Event Data</title>
            <table frame="box" label="TID 10013" rules="all" xml:id="table_TID_10013">
               <caption>CT Irradiation Event Data</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a7752bbc-ea79-405e-84fb-68cf449ca41f"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_77545633-84cb-4c30-877d-b8b1609a8c15">
                           <emphasis role="bold">NL</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e540d0c1-1f91-453b-b341-d86ce89fec6f">
                           <emphasis role="bold">Rel with Parent</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1b33952f-26eb-4779-a3cc-1f4ebffe6d43">
                           <emphasis role="bold">VT</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ab0c21a6-5fd7-4cdb-800a-f1232806b301">
                           <emphasis role="bold">Concept Name</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9b16203e-dc48-416d-a9da-3aa88eb23fbb">
                           <emphasis role="bold">VM</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3882c12d-d555-4398-9e32-9969038eb012">
                           <emphasis role="bold">Req Type</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a796eeb0-27ec-4010-9f92-04caa56775de">
                           <emphasis role="bold">Condition</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_530b8609-1d9b-448d-b2e9-dd01312d2b58">
                           <emphasis role="bold">Value Set Constraint</emphasis>
                        </para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_37d66cae-ac15-4b07-a564-aad3fca78280">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b19e8fe0-71d4-4740-8c8e-c14ff589b100"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_079ae4f7-6d50-4e78-b390-5bd5a7b100bf"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e379aba8-6ac2-4ee5-a85d-4682ce928889">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_071b66b4-c54d-4939-85fd-44eb0b451d27">EV <link linkend="DCM_113819" xrefstyle="select: nopage">(113819, DCM, "CT Acquisition")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b193acb3-32b2-49af-a822-cd59698f4c0d">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a69920e4-2d8b-4f27-96f6-5be3ce35fa5a">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bc338618-9934-4bf4-871a-a93dfc063042"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_296cda33-568d-4db6-91a8-8c55dd97b27a"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c1323f26-ba53-4ac0-9a87-3fe78210d743">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e246dd6-cfdd-44b8-95fd-fc690b2b2cc3">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_00ca9f4d-f4d3-454d-92ea-db03fb2a1523">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_06d64d28-9bb3-4ec4-9029-a48a80114dca">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c9fc37dc-8a18-4f8e-9637-6bc99a6513b5">EV <link linkend="DCM_125203" xrefstyle="select: nopage">(125203, DCM, "Acquisition Protocol")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_727f5404-f1c3-45fc-bcdb-bb9f54244e90">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cb6273b7-bd72-4fe6-b4f4-eeebab26a03f">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dbed400e-5a71-47e1-87d5-ebbacb0fa874"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_da3dacb3-7a45-4cb4-a93e-e52a88868d38"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ce7a1720-2531-424f-bd50-6c096ab697b7">3</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ea27272c-0b56-4846-8c0e-920a1cc5e6d2">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2908dc1f-5ccb-4768-8d97-122f290b0a70">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d44b21d0-76bd-47f0-9c41-484930da930f">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_484b8875-11a3-41b4-8a82-cc05d2661ec4">EV <link linkend="DCM_123014" xrefstyle="select: nopage">(123014, DCM, "Target Region")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_60e7aaaf-d45d-4650-bb11-5edb9397db22">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5804f4d0-6822-4b3b-8dc5-e043e6ba272e">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8b999d2a-4c84-4528-9961-d3d8d6c5c179"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ef1d1a75-62db-4f04-bff4-a8eeadfc1672">D<xref linkend="sect_CID_4030" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cb5fb4e8-6f21-4ba3-9754-ab6c61c2979c">4</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_616eb3a5-66ff-46e0-95af-a61d1a9557fd">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7690f1af-d5e8-43a5-a0f4-4c11f50ab8b2">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_45a89d5e-e05f-4e7e-891a-1cd658fc9596">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_df664e53-7ee7-4053-b3fd-ac58d4013558">EV <link linkend="DCM_113820" xrefstyle="select: nopage">(113820, DCM, "CT Acquisition Type")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_03efc72e-baa2-4050-92ab-0ee8388d9532">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c0d70231-7c37-4bbf-a475-08c8839fd8cc">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8d373077-114a-4ba6-833e-25bf70885e88"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_95d44271-3b73-444d-9131-6286fdff8deb">D<xref linkend="sect_CID_10013" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8403fdfe-e87d-4d76-9ba1-a12b0db5c630">4b</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_23d985b2-6f5d-469a-9694-fb391079f430">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c0f4f6ba-cbde-4ea5-bd2b-9f36c3e3478b"><emphasis role="bold"><emphasis role="strikethrough">CONTAINS</emphasis><emphasis role="underline">HAS PROPERTIES</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5c940492-5a70-4ff3-8e92-941cc418f799">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_46295279-8a10-46a5-ab2f-150c98ae302b">EV <link linkend="DCM_113961" xrefstyle="select: nopage">(113961, DCM, "Reconstruction Algorithm")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_31740d4a-14c0-48cf-94ee-2b2e4487441d">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_098e3e38-5494-4059-a77d-36305f0a1725">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f94722eb-1c93-419c-be56-c5099a4db159"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a26a1525-2945-41fc-b4ea-d6beb0e1b2ed">D<xref linkend="sect_CID_10033" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9e7a8409-a28b-4ec4-9c45-397c233da575">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f956eeb5-d4eb-493b-809f-f20b249a629b">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4efdd4d7-7bf3-4b33-a95c-0022aa7bc8af">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1de301ee-9bd1-4b93-998c-b8c677f0aa73">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_21743ba8-4820-4a91-9afa-eba1df6ce279">EV <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=408730004" xl:show="new">(G-C32C, SRT, "Procedure Context")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1cb88b58-2364-4a75-a58c-aaee02b414e2">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1a3ed39e-85aa-46d1-9e5f-ae0b5f36db24">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7bb27281-88c8-4a5f-b9b5-a67296eb7962"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cf711534-0f0a-4431-98d1-2626802a0400">D<xref linkend="sect_CID_10014" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d769162e-d348-4129-84ff-d634ce7c200b">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ff0e6c1e-505d-4270-ba06-efccc300146e">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_18fcd71b-442b-47f9-aa9b-cbbca4c22b80">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9d72adbe-d5d2-4bc4-b541-e7e96de73f2e">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5b195f70-00c0-4f04-85ac-04df2efdbb94">...</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_65ef3611-da36-413b-b824-c6e9dbaf80cc">...</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e9b9238a-333d-4f0c-9a21-53bb8f6f1258">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7598ff1f-a7cf-4859-8261-15cf16f6bee1">...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_33a9beb0-0769-4049-9376-8cd120a263e4">...</para>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>
        
        
    </chapter>
</book>
