<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1773</title>
    <subtitle>Correct code for common femoral artery in CID 12109</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>2018/03/25</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Janet Keyes</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/08/15</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1773</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Correct code for common femoral artery in CID 12109</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para>
                    <para>CID 12109 uses Code Value T-47400 "structure of femoral artery" for Common Femoral Artery, not T-47402.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title></title>
        <section>
            <title></title>
            <informaltable rules="all" frame="box">
                <tr><td><para><emphasis role="italic">Amend DICOM PS3.16 as follows:</emphasis></para></td></tr>
            </informaltable>
            
            <section label="CID 12109" status="3" xml:id="sect_CID_12109">
         <title>Lower Extremity Arteries</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_a44d58d2-3d2e-42c1-913b-c1b0039bcf8e">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_12109.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_12109.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_12109.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.576.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_2f55af78-9e80-4653-a2ad-6bdad182ebe3">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_22c03cc6-1815-49c0-bfc2-05b468397af7">
                                <emphasis role="bold"><emphasis role="strikethrough">20170914</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                            </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_4a75e62d-f2b3-4d45-8a5e-4c9cdf3ff881">
                     <emphasis role="bold">1.2.840.10008.6.1.576</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 12109" rules="all" xml:id="table_CID_12109">
            <caption>Lower Extremity Arteries</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b985ff8e-1208-471a-8f75-c514155a6033">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4cf6a957-a41b-4665-90cc-4ab7c476a587">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_15726517-44c0-4951-be41-21bdb168984a">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9211f8c5-b27d-4aed-8229-1f43c6c18abb">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_13f90a44-4531-4142-8ab2-5abaa74185c3">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_db592f6a-cf25-4024-83bc-6371e26c86bd">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_40832116-a972-41b8-96c3-3d034fb358c4">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=73634005" xl:show="new">T-46710</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_049de11c-9878-43ce-80cf-6504a557cec3">Common Iliac Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7ad2dc32-c680-49d3-a59c-a338dfa7809a">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=73634005" xl:show="new">73634005</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2c48f684-3079-4973-800e-2d960b6aca7d">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1261084" xl:show="new">C1261084</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a2d07147-4bf1-4120-8ce3-33723281d228">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d6810029-0638-4598-9c27-aae92c47a79a">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=413896006" xl:show="new">R-10258</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b08d755b-644d-4196-a8c8-ef9eccf11f40">Common Iliac Artery Bifurcation</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d1eee5cf-e668-46ee-8162-653f0e9f664d">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=413896006" xl:show="new">413896006</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_38c012ba-135e-4005-8b86-01b86eb57a75">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1531837" xl:show="new">C1531837</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8227e6f3-059c-4b11-bd27-32fd873dfe0e">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1ca3bfd0-c287-40d5-b83b-bcd209d57b5a">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=68053000" xl:show="new">T-47700</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_de739c0e-43ba-4b23-9925-476e438d1416">Anterior Tibial Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0199bc33-9875-478d-bd1c-0a03c3feb141">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=68053000" xl:show="new">68053000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f31eb2b0-368a-4529-957c-fd406fb85e69">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0085816" xl:show="new">C0085816</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_12073d86-1722-4c16-accd-348a7826008b">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f76d3863-e3c2-4e5f-aff3-806bd609103e">
                         <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=7657000" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">T-47400</emphasis></emphasis></link>
                         <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=181347005" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-47402</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5d11745d-0c81-4907-b7c4-cfafc366b557">Common Femoral Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ee4285c9-c1ea-48e7-b2bb-45d68ea138f2">
                         <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=7657000" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">7657000</emphasis></emphasis></link>
                         <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=181347005" xl:show="new"><emphasis role="bold"><emphasis role="underline">181347005</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_09148a30-d117-42bd-ab00-23d0c0c6cc11">
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0015801" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0015801</emphasis></emphasis></link>
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0447105" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0447105</emphasis></emphasis></link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c05853eb-2406-4aa3-a59e-bb7da40819ac">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a52d21cf-cab1-4257-9e0a-e4c65cf2b32e">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=86547008" xl:show="new">T-47740</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c8ff6144-8a80-4d6d-95bb-781b766cd8af">Dorsalis Pedis Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9ce4100d-a9bc-43ee-9ac2-e15c3712e64a">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=86547008" xl:show="new">86547008</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_23ee2124-1ba0-41f2-98e3-d580efd439d3">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0226492" xl:show="new">C0226492</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0eb5e0ab-5208-4d01-ba89-8c5e518db2c3">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_99862d58-8897-469d-9e2c-05b8332358df">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=113269004" xl:show="new">T-46910</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6bf69427-b729-4cae-89a7-f23098398477">External Iliac Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d6a68b0c-a8bc-4950-89b3-a797eeb8c6ed">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=113269004" xl:show="new">113269004</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d0671fef-fd31-4aae-b46a-140138bf7015">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0226398" xl:show="new">C0226398</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf66d807-e2d9-4c80-858d-f7667dc05281">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d54ec2c8-aa78-404d-a6d3-c714d6840334">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=90024005" xl:show="new">T-46740</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5ceec5f1-075c-454e-8a46-35f3e5734210">Internal Iliac Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b5cf293-2228-4be4-abb0-b0ead6548366">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=90024005" xl:show="new">90024005</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fff55f3a-8dae-473b-baae-3030cfcc1f46">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0226364" xl:show="new">C0226364</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_28431e10-4330-4450-9d01-fa1a98117510">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3019ddef-c2d4-43b3-952b-f42882c3a643">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=8821006" xl:show="new">T-47630</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ddd105bb-d361-4abe-9a13-ee99c3d416ec">Peroneal Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2db0898d-d43e-4f18-8aa9-16008dac6634">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=8821006" xl:show="new">8821006</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a979da7d-7b74-49d2-83bd-aac010fe34e6">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0226476" xl:show="new">C0226476</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c1b3db36-a1c9-4e9a-b288-5b764afadf63">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3a58d4c0-9fcf-4ffa-b807-242f64e7f2d1">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=83018002" xl:show="new">T-47690</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0b665482-9c4d-435f-8a9b-bc76264b5c2c">Plantar Arterial Arch</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0b5140df-d80d-4374-b74a-7c909b64c17f">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=83018002" xl:show="new">83018002</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3c0cb319-4d3a-48ca-9253-f31a42f6e41b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0226482" xl:show="new">C0226482</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c1fdaeba-d033-4007-9994-1db3ae8ac73d">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9815ba1d-5cd9-4668-bb6b-a203069d4ca6">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=43899006" xl:show="new">T-47500</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_20ba2c99-3c7f-4113-9343-d97c27c7f7a9">Popliteal Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bbbd006c-8c83-4bc9-ad40-26bf88e8ab72">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=43899006" xl:show="new">43899006</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_69ddde83-6b89-4425-8675-bb6c643bcb0f">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0032649" xl:show="new">C0032649</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c3ee8862-4e80-4c5c-8168-d71f8b4fd4c7">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c21948f3-cac7-4392-b795-6da2a448a0f2">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=13363002" xl:show="new">T-47600</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_52dcc6cb-a1cc-46f4-bcec-6748cde5c84d">Posterior Tibial Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9e7cb99d-fe9f-4e85-b290-13f978ce6f00">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=13363002" xl:show="new">13363002</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b819bd9a-03e0-498e-960b-64a571abdd8a">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0086835" xl:show="new">C0086835</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b398d456-a5f4-4e07-b778-731dfc07d301">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_20da0a52-d109-4884-b756-379c25b4ccb1">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=31677005" xl:show="new">T-47440</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a7a9bdbd-1799-4cde-82eb-e85e0318657c">Profunda Femoris Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ec85dc1a-780c-4b84-9219-a02bb81cdc84">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=31677005" xl:show="new">31677005</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2e355772-b491-48c2-a98d-9cc60fafe3ec">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0226455" xl:show="new">C0226455</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_49dd79c8-ed0f-4fa7-a92f-72116fcfdea1">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_565cde81-c99d-4f5d-a52e-9f0833da4e48">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=181349008" xl:show="new">T-47403</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0eb9a0d8-8687-4f27-832d-1bb7019f91cb">Superficial Femoral Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ac05b4ad-48e2-4034-bb11-4f3867dbee1c">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=181349008" xl:show="new">181349008</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_af305b84-30b1-4f4d-8c6a-a1bb624c54db">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0447106" xl:show="new">C0447106</link>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
            
            
        </section>
    </chapter>
</book>
