<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1765</title>
    <subtitle>Retire DICOMDIR reference to unencapsulated CDA on media</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>March 2018 Voting Packet</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/01/23</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/12/03</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1765</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Retire DICOMDIR reference to unencapsulated CDA on media</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3, PS3.6, PS3.10</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Sup 101 HL7 Structured Document Object References (FT 2005/06/15) added a mechanism to reference
                    non-DICOM files, specifically HL7 CDA files and/or MIME multipart-related files containing HL7 CDA
                    and their accompanying supporting files. Sup 114 DICOM Encapsulation of CDA Documents (FT 2007/01/22)
                    provided an alternative mechanism with the ability to encapsulated CDA in DICOM, and extended rather
                    than retiring the previously defined mechanism.</para>
                    <para>It is proposed to retire the unencapsulated approach, since there is no evidence that indexing unencapsulated CDA files from the DICOMDIR has ever been used, encapsulation is the preferred approach (consistent with the approach for PDF and 3D manufacturing formats), and IHE specifies alternative mechanisms for indexing metadata for non-DICOM files (XDM profile).</para>
                    <para>This change does not preclude inclusion of unencapsulated CDA (or any other) format documents that are not referenced by the DICOMDIR, e.g., in the manner defined in the IHE XDM profile in which such non-DICOM files are described in the METADATA.XML file.</para>
                    <para>The corresponding Transfer Syntaxes are also retired, since they are not used for any other purpose in DICOM.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.10 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="strikethrough">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="B" status="1" xml:id="chapter_B">
            <title>HL7 Structured Document Files</title>
            <para xml:id="para_d09fcd28-7c53-41fd-910f-acdfd269b539">Structured Documents as defined by an HL7 standard may be stored on DICOM Interchange Media, and may be referenced from within DICOM SOP Instances (including the DICOMDIR Media Storage Directory). <emphasis role="bold"><emphasis role="strikethrough">There are two alternatives for storage of such documents - they may be encapsulated in DICOM SOP Instances, or they may be stored as native HL7 objects (unencapsulated).</emphasis></emphasis></para>
            <para xml:id="para_74aeb243-f9b2-4c22-90d8-cd1d4cd4449d">An Encapsulated CDA is referenced from the Media Storage Directory like any other DICOM SOP Instance.</para>
            <para xml:id="para_c3493caf-5123-4dad-9d52-6d93f44c84ce"><emphasis role="bold"><emphasis role="strikethrough">References to a native (unencapsulated) Structured Document use a SOP Class UID, identifying the document class, and a SOP Instance UID. The SOP Instance UID is arbitrary, and the native document instance identifier is encoded in the HL7 Instance Identifier (0040,E001) attribute (see <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>, "HL7 Structured Document Directory Record Definition" and "HL7 Structured Document Reference Sequence" for further information).</emphasis></emphasis></para>
            <note>
                <orderedlist>
                    <listitem>
                        <para xml:id="para_8437f895-396d-43fa-b211-3831885a7231">The HL7 standards that define such documents include the Clinical Document Architecture (CDA), Structured Product Labeling (SPL), and Structured Clinical Trial Protocol (SCTP) standards.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_99d89b3d-18d7-4412-9fa7-b41119b50013">The SOP Instance UID used to reference a particular HL7 Structured Document is not necessarily the same in all DICOM Instances. <emphasis role="bold"><emphasis role="strikethrough">E.g., an SR Document and a DICOMDIR, both stored on the same media, may <emphasis role="italic">internally</emphasis> use different SOP Instance UIDs to reference the same HL7 Structured Document, but they will each provide a mapping to the same HL7 Instance Identifier as the <emphasis role="italic">external</emphasis> identifier.</emphasis></emphasis></para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_e1e9c0b9-d084-465c-896c-8409bec9bffd">It is recommended that <emphasis role="bold"><emphasis role="strikethrough">an HL7 Structured Document that can be associated with a patient and study be encapsulated in a DICOM SOP Instance, and that </emphasis></emphasis>the SOP Instance UID of <emphasis role="bold"><emphasis role="strikethrough">that encapsulation</emphasis><emphasis role="underline">the encapsulated CDA instance</emphasis></emphasis> be used consistently for all references.</para>
                    </listitem>
                </orderedlist>
            </note>
            <para xml:id="para_b769b282-8692-4bcf-b2dd-6b2dfaba79ec">An HL7 Structured Document is an aggregate multimedia object, consisting of a base XML-encoded document, plus zero or more multimedia components (e.g., graphics) that are considered an integral part of the object. The multimedia components <emphasis role="bold"><emphasis role="strikethrough">may</emphasis><emphasis role="underline">shall</emphasis></emphasis> be encoded in-line in the <emphasis role="bold"><emphasis role="underline">encapsulated </emphasis></emphasis>XML document<emphasis role="bold"><emphasis role="strikethrough">, or they may be referenced external objects</emphasis><emphasis role="underline">unless they are references to other DICOM SOP Instances contained on the media</emphasis></emphasis>.</para>
            <para xml:id="para_07576d08-d9ba-4b8f-85f6-9c3bfa229cc5"><emphasis role="bold"><emphasis role="strikethrough">Such a document stored on DICOM Interchange Media shall be encoded as either:</emphasis></emphasis></para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_d2340592-3e8c-4087-b110-3e2e68e011e9"><emphasis role="bold"><emphasis role="strikethrough">an XML document with any multimedia components encoded in-line, and stored in a single file. The file shall be stored on the media with a File ID as defined for DICOM files. There shall be no preamble or header in the file prior to the XML content. For the purpose of identifying the Transfer Syntax of such a stored file from the DICOMDIR, the Transfer Syntax UID "1.2.840.10008.1.2.6.2" is specified for an XML encoded document.</emphasis></emphasis></para>
                </listitem>
                <listitem>
                    <para xml:id="para_6de5b624-b435-4b8e-b72f-bf444281d3cb"><emphasis role="bold"><emphasis role="strikethrough">a Multipart MIME package, as described in RFC2557 "MIME Encapsulation of Aggregate Documents, such as HTML (MHTML) " (http://www.ietf.org/rfc/rfc2557.txt). A single package shall be stored in a single file, and shall encapsulate a single HL7 Structured Document and its referenced multimedia. The file shall be stored on the media with a File ID as defined for DICOM files. There shall be no preamble or header in the file prior to the MIME headers. For the purpose of identifying the Transfer Syntax of such a stored file from the DICOMDIR, the Transfer Syntax UID "1.2.840.10008.1.2.6.1" is specified for RFC2557 MIME Encapsulation.</emphasis></emphasis></para>
                </listitem>
            </itemizedlist>
            <note>
                <para xml:id="para_1f9af0ef-1dba-417d-bef9-5521820cac9d"><emphasis role="bold"><emphasis role="strikethrough">The File ID, consistent with DICOM file naming rules, is limited to eight characters with no extension, in a directory structure where each directory is limited to an eight character name. There may also be alternate file identifiers (e.g., links) to those files that use less restricted file names (see <xref linkend="sect_8.2" xrefstyle="select: label"/>).</emphasis></emphasis></para>
            </note>
            <para xml:id="para_97316db2-c564-4951-a16e-d14b26c77089"><emphasis role="bold"><emphasis role="strikethrough">Any multimedia component that is included by reference in multiple HL7 Structured Documents stored on the same media shall be replicated into each referencing document MIME package.</emphasis></emphasis></para>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="strikethrough">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="F.4" status="2" xml:id="sect_F.4">
      <title>Basic Directory IOD Information Model</title>
      <table frame="box" label="F.4-1" rules="all" xml:id="table_F.4-1">
        <caption>Relationship Between Directory Records</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_d9f6b9e5-5f4a-4dad-9fab-05bf25e07c9f">Directory Record Type</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_24d7decd-cf27-45a3-8d89-94f79cf6f8ef">Section</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_8b60f85f-e6bf-46b6-8af7-9be039579850">Directory Record Types that may be included in the next lower-level directory Entity</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c2a38a50-31ae-4cbf-b3dc-2c71610f13e1">(Root Directory Entity)</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_469d047d-3bc7-4977-8ca6-6aaca1236351"/>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_6588550a-c011-48a8-895a-98728c733c6b">PATIENT, HANGING PROTOCOL, PALETTE, IMPLANT, IMPLANT ASSY, IMPLANT GROUP, PRIVATE</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_045da296-12f9-4cef-b579-0be021b1b4c8">PATIENT</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_3b7d9609-ea8e-48ad-996f-c408fba03c95">
<xref linkend="sect_F.5.1" xrefstyle="select: labelnumber"/>
</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_36becdc5-d74e-42d9-8473-ec837227d568">STUDY, <emphasis role="bold"><emphasis role="strikethrough">HL7 STRUC DOC, </emphasis></emphasis>PRIVATE</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_1761b872-6d0e-46a3-b7ae-e8f227db414b">STUDY</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_d1998bdf-551c-4007-9546-7651440f748a">
<xref linkend="sect_F.5.2" xrefstyle="select: labelnumber"/>
</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c0ec4177-32dc-41eb-a2e4-7953f4e2a169">SERIES, PRIVATE</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b07d9817-faa5-49aa-affd-13ecaf89b46e">SERIES</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_8a0001e6-1c78-40bf-9d88-3a9cf91b2200">
<xref linkend="sect_F.5.3" xrefstyle="select: labelnumber"/>
</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_593b3f35-a1fc-4f29-8dc7-b101b6c083f7">IMAGE, RT DOSE, RT STRUCTURE SET, RT PLAN, RT TREAT RECORD, PRESENTATION, WAVEFORM, SR DOCUMENT, KEY OBJECT DOC, SPECTROSCOPY, RAW DATA, REGISTRATION, FIDUCIAL, ENCAP DOC, VALUE MAP, STEREOMETRIC, PLAN, MEASUREMENT, SURFACE, TRACT, ASSESSMENT, PRIVATE</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_dfcf61f7-883b-4010-b1ba-e4328597fca4">IMAGE</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_d57238c2-49e3-4882-8e3e-5125a57c8ba0">
<xref linkend="sect_F.5.4" xrefstyle="select: labelnumber"/>
</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_4c1407db-5a37-460f-a68f-6fd6fd34c51f">PRIVATE</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_a34b0f13-3eff-45e5-bff1-b1505badc600">...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_9476253a-86a8-4b8e-9273-32472266e8fd"> ... </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_bbfc0c8d-f811-4610-a3db-43a91545eca6">...</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_7bfaa5f6-6608-4a0c-bc36-4d128cdb1dfd">ENCAP DOC</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_726bd3e6-3f9b-4f83-81a9-b594b47a3da0">
<xref linkend="sect_F.5.32" xrefstyle="select: labelnumber"/>
</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_498774db-ce2b-4858-86cf-c66ef06cdf1e">PRIVATE</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_7d924db9-3986-4a99-8c4a-ba443fda05df"><emphasis role="bold"><emphasis role="strikethrough">HL7 STRUC DOC</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_72b600a0-53a9-409f-b112-27794627c0bd"><emphasis role="bold"><emphasis role="strikethrough">
<xref linkend="sect_F.5.33" xrefstyle="select: labelnumber"/>
                </emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_c3c2db00-9c2d-46aa-8621-139e47f2e1dd"><emphasis role="bold"><emphasis role="strikethrough">PRIVATE</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_d1274763-647e-4b5a-ba07-1ee629b64e4b">...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c8e38076-98fe-43fd-94d9-fb3abf7c63ee"> ... </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_2dfb3908-bf62-4c91-9332-70abc08f150e">...</para>
            </td>
          </tr>
        </tbody>
      </table>
      <note>
        <orderedlist numeration="arabic">
          <listitem>
            <para xml:id="para_2f07e274-c83d-4f05-ac54-ea2a10f2443b">Directory Record Types PRINT QUEUE, FILM SESSION, FILM BOX, and IMAGE BOX were previously defined in DICOM. They have been retired. See PS3.3-1998.</para>
          </listitem>
          <listitem>
                        <para xml:id="para_f73d61c4-ea90-4399-97d6-d25e6ce5b6b5">Directory Record Types OVERLAY, MODALITY LUT, VOI LUT, CURVE, TOPIC, VISIT, RESULTS, INTERPRETATION, STUDY COMPONENT, STORED PRINT and MRDR were previously defined in DICOM. They have been retired. See <link xl:href="ftp://medical.nema.org/MEDICAL/Dicom/2004/printed/04_03pu3.pdf">PS3.3-2004</link>.</para>
                    </listitem>
                    <listitem>
                        <para><emphasis role="bold"><emphasis role="underline">Directory Record Type HL7 STRUC DOC was previously defined in DICOM. It has been retired. See PS3.3 20xxy.</emphasis></emphasis></para>
                    </listitem>
        </orderedlist>
      </note>
    </section>
        <section label="F.5" status="2" xml:id="sect_F.5">
            <title>Definition of Specific Directory Records</title>
            <informaltable rules="all" frame="box">
                <tr>
                    <td>
                        <para><emphasis role="italic">Replace old Figure F.4-1:</emphasis></para>
                    </td>
                </tr>
            </informaltable>
            <para xml:id="para_ac1cdd03-be7a-4723-b4b3-2c7f7db62d10">
                <figure label="F.4-1" pgwide="1" xml:id="figure_F.4-1">
                    <title>Basic Directory IOD Information Model</title>
                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="cp1765/PS3.3_F.4-1_old.svg"/>
                        </imageobject>
                    </mediaobject>
                </figure>
            </para>
            <informaltable rules="all" frame="box">
                <tr>
                    <td>
                        <para><emphasis role="italic">with new Figure F.4-1 that does not contain HL7 STRUC DOC:</emphasis></para>
                    </td>
                </tr>
            </informaltable>
            <para>
                <figure label="F.4-1" pgwide="1" xml:id="figure_F.4-1">
                    <title>Basic Directory IOD Information Model</title>
                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="cp1765/PS3.3_F.4-1_new.svg"/>
                        </imageobject>
                    </mediaobject>
                </figure>
            </para>
            <note>
                <para xml:id="para_ee8775c5-33b6-4589-800c-bf8c7b8118b1">Normalized Print media storage was previously defined in DICOM. It is now retired. See PS3.3-1998.</para>
            </note>
            <para>...</para>
        <section label="F.5.33" status="3" xml:id="sect_F.5.33">
            <title>HL7 Structured Document Directory Record Definition</title>
            <emphasis role="bold">
                <para xml:id="para_e86935d5-c8a1-4a70-91fa-7a925e2dc9a0"><emphasis role="underline">Retired. See PS3.3 20xxy.</emphasis>
                    <emphasis role="strikethrough">The Directory Record is based on the specification of <xref linkend="sect_F.3" xrefstyle="select: label"/>. It is identified by a Directory Record Type of Value "HL7 STRUC DOC".</emphasis></para>
            </emphasis>
            <para xml:id="para_ba37870f-e288-4fc2-8e7e-e89c0009ebfe"><emphasis role="bold"><emphasis role="strikethrough">
                        <xref linkend="table_F.5-33" xrefstyle="select: label"/> lists the set of keys with their associated Types for such a Directory Record Type. This Directory Record shall be used to reference an HL7 Structured Document and any of its referenced content stored on the interchange media but not encapsulated in a DICOM SOP Instance. The document may be encoded as an XML document with in-line multimedia content, or may be encoded in a multi-part MIME wrapper (see <olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/>). This type of Directory Record may reference a Lower-Level Directory Entity that includes one or more Directory Records as defined in <xref linkend="table_F.4-1" xrefstyle="select: label"/>.</emphasis></emphasis></para>
            <table frame="box" label="F.5-33" rules="all" xml:id="table_F.5-33">
                <caption><emphasis role="strikethrough">HL7 Structured Document Keys</emphasis></caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e91915b-c52a-4531-b38b-12df1124f7ec"><emphasis role="strikethrough">Key</emphasis></para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2137a3e1-dca3-4fdb-8443-47d0f654b07f"><emphasis role="strikethrough">Tag</emphasis></para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4739380c-1f4a-45ba-84d1-1a8f22941998"><emphasis role="strikethrough">Type</emphasis></para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5bdd807c-ecc5-449b-9c2d-165a71b606b9"><emphasis role="strikethrough">Attribute Description</emphasis></para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8ce36757-7b56-49df-b852-66375f8fdb48"><emphasis role="bold"><emphasis role="strikethrough">Specific Character Set</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_17c8384f-7ee1-4664-bde6-d9819963e17d"><emphasis role="bold"><emphasis role="strikethrough">(0008,0005)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf45d8dd-f11c-4757-9322-b616c071222e"><emphasis role="bold"><emphasis role="strikethrough">1C</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cb92f8bf-e132-4738-a729-dae4088bb894"><emphasis role="bold"><emphasis role="strikethrough">Required if an extended or replacement character set is used in one of the keys.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_daf7d369-b245-4b6f-9e8e-3dea073059b0"><emphasis role="bold"><emphasis role="strikethrough">HL7 Instance Identifier</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c32752d-9a05-45e8-b0a7-f9861e4db943"><emphasis role="bold"><emphasis role="strikethrough">(0040,E001)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4096156e-50f3-4e1b-b103-cc551373efdf"><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9a12dc61-63cd-4340-9480-806de20db73f"><emphasis role="bold"><emphasis role="strikethrough">Instance Identifier from the referenced HL7 Structured Document, encoded as a UID (OID or UUID), concatenated with a caret ("^") and Extension value (if Extension is present in Instance Identifier).</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bc6134b4-6250-4666-aeba-a8862da6c886"><emphasis role="bold"><emphasis role="strikethrough">HL7 Document Effective Time</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f28f1f77-6f39-4180-aa18-1fa1f226f79f"><emphasis role="bold"><emphasis role="strikethrough">(0040,E004)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8fd1c5bf-05e4-441c-ba0e-e3f717821978"><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_26afda56-224b-4e9e-a27b-1cedf703d69c"><emphasis role="bold"><emphasis role="strikethrough">Effective Time from the referenced HL7 Structured Document</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_660efe6a-c636-4308-bb57-cd72760c2e16"><emphasis role="bold"><emphasis role="strikethrough">HL7 Document Type Code Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e3b962f-2df2-4b92-bddd-c28dbc5f0118"><emphasis role="bold"><emphasis role="strikethrough">(0040,E006)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e56ad24f-647b-4468-9fce-9bfbb91de3ad"><emphasis role="bold"><emphasis role="strikethrough">1C</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_05f209fa-a2ee-4675-983f-511bf5d28128"><emphasis role="bold"><emphasis role="strikethrough">Document Type Code from the referenced HL7 Structured Document.</emphasis></emphasis></para>
                            <para xml:id="para_9b70bd25-72a7-4a0d-a89d-391bd5e27ce1"><emphasis role="bold"><emphasis role="strikethrough">Only a single Item shall be included in this Sequence.</emphasis></emphasis></para>
                            <para xml:id="para_99713663-f42d-458c-9eec-f9c6ad80c7a6"><emphasis role="bold"><emphasis role="strikethrough">Required if the HL7 Structured Document contains a Document Type Code.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_8eb34c8b-a08d-42e6-b58f-6dd74f060368">
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="strikethrough">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_67a0faf9-0699-4d14-8ac4-141f8e405c89"><emphasis role="bold"><emphasis role="strikethrough">No BCID defined</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fa4aec41-0cb9-4a69-b59a-320bc5b23438"><emphasis role="bold"><emphasis role="strikethrough">Document Title</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_35933992-f5a6-4d2f-b6b8-8bce2bb46afe"><emphasis role="bold"><emphasis role="strikethrough">(0042,0010)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2b5aab8f-3989-4bf2-b778-c7eb41ce1d40"><emphasis role="bold"><emphasis role="strikethrough">1C</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d5977dd0-6d69-4692-8168-0ff559ce18dc"><emphasis role="bold"><emphasis role="strikethrough">Document Title from the referenced HL7 Structured Document.</emphasis></emphasis></para>
                            <para xml:id="para_e62b037b-7a82-4047-bfeb-6e8f866326fb"><emphasis role="bold"><emphasis role="strikethrough">Required if the HL7 Structured Document contains a Document Title.</emphasis></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <para xml:id="para_d55da23a-82a0-4a40-93eb-ad1740e85a44"><emphasis role="bold"><emphasis role="strikethrough">This directory record points to a CDA document that is stored on this media. The HL7 Document Effective Time and other information can be obtained from the CDA document.</emphasis></emphasis></para>
            </note>
        </section>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.6 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="strikethrough">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="A" status="1" xml:id="chapter_A">
            <title>Registry of DICOM Unique Identifiers (UIDs) (Normative)</title>
            
            <table frame="box" label="A-1" rules="all" xml:id="table_A-1">
                <caption>UID Values</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89103697-fd54-4c3f-abbe-5655ae35308b">
                                <emphasis role="bold">UID Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb5b6b8a-9aec-44f2-8cdc-800a7cd327b7">
                                <emphasis role="bold">UID Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08eb5599-7f50-4d17-bd10-6617063c6e31">
                                <emphasis role="bold">UID Type</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42e221e9-efb2-49d7-8712-69266c9bc2d4">
                                <emphasis role="bold">Part</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
        <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_3df634f7-77b5-4f18-aa29-cde9919df45b"><emphasis role="italic">1.2.840.10008.1.2.​6.​1</emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_b855777a-4e64-463b-b245-2e2710cf48c9"><emphasis role="italic">RFC 2557 MIME encapsulation<emphasis role="bold"><emphasis role="underline"> (Retired)</emphasis></emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_af8d6924-bc08-46ae-be6a-28b4f8a3b0d8"><emphasis role="italic">Transfer Syntax</emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_0a80c950-5e60-4bec-93e4-3cb38eb74cf0"><emphasis role="italic">
                    <olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/>
                </emphasis></para>
            </td>
        </tr>
        <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_53f43ea5-d535-4d60-8cd4-3bd02b74a9bf"><emphasis role="italic">1.2.840.10008.1.2.​6.​2</emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_b769ec49-3b83-4d5e-9d1e-bb226e029afd"><emphasis role="italic">XML Encoding<emphasis role="bold"><emphasis role="underline"> (Retired)</emphasis></emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_31da399b-5bba-46fd-b03e-7a1301d39d1c"><emphasis role="italic">Transfer Syntax</emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_d1fa864e-ea1a-41cd-8f1c-be14420a29ae"><emphasis role="italic">
                    <olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/>
                </emphasis></para>
            </td>
        </tr>
                </tbody>
            </table>
        </section>
        
        
    </chapter>
</book>
