<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1764</title>
    <subtitle>More quantitative image features</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/08/06</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para>
                    <para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
           <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>QIICR</para></td>
           </tr>
           <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/12/03</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1764</para></td>
            </tr>
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Log Summary: More quantitative image features</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                  <para>CP 1705 added codes for a comprehensive set of texture features, but more features can be extracted from images than are currently included in DICOM.</para>
                   <para>This CP includes revisions to how to encode features, what features are available, and the description of certain aspects of how they are derived (which affect their interpretation/repeatibility).</para>
                   <para>Now that IBSI defines its own codes, some DCM codes are no longer necessary and are retired with reference to the IBSI codes. IBSI is added as a coding scheme. Also add the Radiomics Ontology (RO) as a coding scheme, since some concepts are require from it.</para>
                  <para>An example of usage of a broad range of radiomic features, without reference to standard definitions and highlighting the need for them, is found in Kalpathy-Cramer J et al. Radiomics of Lung Nodules: A Multi-Institutional Study of Robustness and Agreement of Quantitative Imaging Features. Tomography. 2016 Dec;2(4):430–7. <link xl:href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5279995/"/>.]</para>
                  <para>The proposed quantitative image features context group includes generic size and intensity measurements and hence the measurement parameter invoked in TID 1500 are simplified. The title of the the context group is "quantitative image features" rather than "radiomics" since these have more general applications than just radiology.</para>
                    <para><emphasis role="italic">[Ed.Note.: Update IBSI coding scheme with new reference when published (current v6 on arXiv does not contain the codes.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note.: Use references to RO for kinds of matrices rather than defining them in Annex D (e.g., GLCM)?]</emphasis></para>
                  <para><emphasis role="italic">[Ed.Note.: Add CODE and TEXT numeric parameters to TID 300 and TID 1419 to handle methods and stuff]</emphasis></para>
               <para><emphasis role="italic">[Ed.Note.: Add Law's texture features.]</emphasis></para>
                  <para><emphasis role="italic">[Ed.Note.: Add Local Binary Patterns (LBP), 2D+t (dynamic) features as used in Larroza A, López-Lereu MP, Monmeneu JV, Gavara J, Chorro FJ, Bodí V, et al. Texture analysis of cardiac cine magnetic resonance imaging to detect nonviable segments in patients with chronic myocardial infarction. Med Phys [Internet]. 2018 Feb [cited 2018 Feb 25]; Available from: http://onlinelibrary.wiley.com/doi/10.1002/mp.12783/abstract
                     ]</emphasis></para>
               <para><emphasis role="italic">[Ed. Note. Add Fourier features, e.g., as referenced from Cunliffe AR, Armato SG, Fei XM, Tuohy RE, Al-Hallaq HA. Lung texture in serial thoracic CT scans: Registration-based methods to compare anatomically matched regions. Med Phys. 2013 Jun 1;40(6Part1):.]</emphasis></para>
               <para><emphasis role="italic">[Ed. Note. consider referencing textbooks., e.g., Pratt, Chapter 12 of Computer Vision - Wagner.]</emphasis></para>
               <para><emphasis role="italic">[Ed. Note. Add fractal dimension calculation methods summarized in Cunliffe (blanket, Brownian motion, box counting)]</emphasis></para>
               <para><emphasis role="italic">[Ed.Note.: Add parameters, e.g., for GLCM, thresholds, number of gray levels, number of directions (? list them), step distance, method (2D or 3D +/- merging); see :</emphasis></para>
               <para><emphasis role="italic">Foy JJ, Mitta P, Nowosatka LR, Mendel KR, Li H, Giger ML, et al. Variations in algorithm implementation among quantitative texture analysis software packages. In: Medical Imaging 2018: Computer-Aided Diagnosis [Internet]. International Society for Optics and Photonics; 2018 [cited 2018 Mar 9]. p. 105751K.
                  Available from: <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://dx.doi.org/10.1117/12.2292573">http://dx.doi.org/10.1117/12.2292573</link></emphasis></para>
               <para><emphasis role="italic">Emaminejad N, Wahi-Anwar M, Hoffman J, Kim GH, Brown MS, McNitt-Gray M. The effects of variations in parameters and algorithm choices on calculated radiomics feature values: initial investigations and comparisons to feature variability across CT image acquisition conditions. In: Medical Imaging 2018: Computer-Aided Diagnosis [Internet]. International Society for Optics and Photonics; 2018 [cited 2018 Mar 8]. p. 105753W.
                  Available from: <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://dx.doi.org/10.1117/12.2293864">http://dx.doi.org/10.1117/12.2293864</link>]</emphasis></para>
               <para><emphasis role="italic">[Ed. Note.: means to identify/distinguish intensity mask and  morphological mask for SEG and contours per IBSI Image Processing description]</emphasis></para>
               <para><emphasis role="italic">[Ed.Note.: Are all features ROI only, or can they also be Quantity for images? IBSI is only about ROIs, but Pratt textbook discusses computation of GLCM on sufficient "window" size to be statistically reliable.]</emphasis></para>
               <para><emphasis role="italic">[Ed.Note.: Test case - check have sufficient coverage of features in Al-Kadi OS. Assessment of texture measures susceptibility to noise in conventional and contrast enhanced computed tomography lung tumour images. Computerized Medical Imaging and Graphics. 2010 Sep 1;34(6):494–503.]</emphasis></para>
               <para><emphasis role="italic">[Ed.Note.: For color features (e.g., slide microscopy) consider how to parameterize with which channel and/or ,mean of channels texture applies to; compare with Table 1: "List of the patch level texture features for red and blue channel" in Wen S, Kurc TM, Gao Y, Zhao T, Saltz JH, Zhu W. A methodology for texture feature-based quality assessment in nucleus segmentation of histopathology image. Journal of Pathology Informatics. 2017 Jan 1;8(1):38. doi: 10.4103/jpi.jpi_43_17]</emphasis></para>
               <para><emphasis role="italic">[Ed.Note.: Are the features the base quantity (the measurement itself) or the Derivation (e.g.,, texture feature of ADC, T2WI, SUV, CT HU, esp. in same Study)?]</emphasis></para>
               </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
       
       <section label="2" status="1" xml:id="chapter_2">
          <title>Normative References</title>
          <para xml:id="para_1589f5e4-c13c-4b23-aa20-8280f62270a0">The following standards contain provisions that, through reference in this text, constitute provisions of this Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this Standard are encouraged to investigate the possibilities of applying the most recent editions of the standards indicated below.</para>
          <bibliography>
             <title/>
             <bibliodiv label="2.1" status="2" xml:id="sect_2.1">
                <title>General</title>
       <biblioentry xml:id="biblio_IBSI_Features">
          <abbrev>IBSI Features</abbrev>
          <biblioset relation="journal">
             <title>arXiv</title>
          </biblioset>
          <biblioset relation="article">
             <authorgroup>
                <author>
                   <personname>Zwanenburg A</personname>
                </author>
                <author>
                   <personname>Leger S</personname>
                </author>
                <author>
                   <personname>Vallières M</personname>
                </author>
                <author>
                   <personname>Löck S</personname>
                </author>
             </authorgroup>
             <date>17 Apr 2018</date>
              <volumenum>arXiv:1612.07003v6</volumenum>
             <title>Image biomarker standardisation initiative - feature definitions</title>
          </biblioset>
          <bibliosource>
              <link xl:href="https://arxiv.org/abs/1612.07003"/>
          </bibliosource>
       </biblioentry>
             </bibliodiv>
          </bibliography>
       </section>
        
    
        <section label="8" status="1" xml:id="chapter_8">
      <title>Coding Schemes</title>
            <para>...</para>
      <table frame="box" label="8-1" rules="all" xml:id="table_8-1">
         <caption>Coding Schemes</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5ab47e20-56a9-4356-aa18-622a6f09a5a5">Coding Scheme Designator (0008,0102)</para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_392f55a3-f29a-44ca-a7a9-89367a39f630">Coding Scheme UID (0008,010C)</para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e1ebd38e-42a4-4cee-893f-4d94b6cda509">Coding Scheme Name (0008,0115)</para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_6c129c67-2d60-4b3f-90ee-9d360c87dfb4">Coding Scheme Responsible Organization (0008,0116)</para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1aba1229-a828-4944-a5a1-0d7f5ee47291">Coding Scheme Resources Sequence (0008,0109) Type: URL</para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_fe5d74ea-0181-4ede-aebd-1dd601771111">Description</para>
               </th>
            </tr>
         </thead>
         <tbody>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_3033a660-ccf2-408d-9c44-3bf1c38b57f3">...</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2a78e2af-579c-42bb-96d7-adf8a53d8be6"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_05b03eb7-cfe0-4f88-96cf-16146e4525c5"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_25c9bf13-bd43-476e-b209-c110d368eab1"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e22105ad-020d-4296-82a4-15c3401e4d5d"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_15d404c3-c3af-4cbe-bcca-ee209158af0c"/>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">Image Biomarker Standardisation Initiative</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://arxiv.org/abs/1612.07003">http://arxiv.org/abs/1612.07003</link></emphasis></emphasis>
                            </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e9fdce30-cc49-4d18-8fab-7ef3e031ddbc">...</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5df40702-2f61-4f84-8cdb-9e41463eb92a"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_b8bb7ff2-154a-4ef4-97c9-b2cf376d9ab1"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_42b55d39-2a6e-49cd-a697-18d31bc1e08b"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6e63ba13-af62-4ac0-aa6d-9fa379ac9eab"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f3d3c8b7-2a3f-4d92-9c91-8ef4f08be1e9"/>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">RO</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">Radiomics Ontology</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://bioportal.bioontology.org/ontologies/RO">http://bioportal.bioontology.org/ontologies/RO</link></emphasis></emphasis>
                            </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d713a9b2-febe-4e9f-951f-f4a502efd1d7">...</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a0b358aa-0556-449a-af96-399375da24df"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2ff0e46d-aaaf-4ebc-b2cc-2eacf65ed283"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_07039b6a-8f30-4a5b-8d4d-2ab40a648ad4"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_dc389902-74bf-4ef1-98e0-0b689d613ac7"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_433d6ab1-5902-453c-8e46-7f799ff853a7"/>
               </td>
            </tr>
         </tbody>
      </table>
   </section>
       
       <section label="TID 300" status="3" xml:id="sect_TID_300">
            <title>Measurement</title>
            <para xml:id="para_77bd792c-bd9d-4e95-bb1e-f3846ddcda7f">This Template provides a general structure for a numeric measurement, together with evaluations of its normality and/or significance, and the inference source(s) for its value. This structure is instantiated by inclusion of this Template with specific contextual parameters from a parent Template.</para>
            <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300_Parameters">
               <caption>Parameters</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e78884e8-2fba-44cb-9543-7b13a3f3d74f">Parameter Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_87aed517-66ec-469b-848a-051450840c1d">Parameter Usage</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e039a3ff-536a-4dca-bf00-b2d2fa99111c">$Measurement</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a5457f0f-7d97-406d-aa13-d6be91f9b149">Coded term or Context Group for Concept Name of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f6d70f93-7707-424a-9d79-3adcab4db4c0">$Units</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3badc168-22a5-4682-9b57-047d848b2f30">Units of Measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6989484c-b1da-4d6a-bda3-d9a7d3583ca1">$ModType</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d3979d08-a959-4113-aa01-a1840e7cb7d6">Modifier Name for Concept Name of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2220407e-bc25-4ccf-8b5d-0c95d1ddf80f">$ModValue</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b95a5982-014a-4d8f-a6a4-c5fb5c4a1f7c">Modifier Value for Concept Name of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c8bcec88-37d6-4561-b828-e4d6ef3790fc">$Method</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e6519c4-97df-4e09-8762-4dd0dff32912">Value for Measurement Method</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d22fd402-fc81-4e8d-a0de-24ba7e68e491">$Derivation</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a2abc1bf-a237-476b-adef-31ef6cada34e">Value for Measurement Derivation</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_336246da-7a84-428a-9e3e-412fdc412444">$TargetSite</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eb6a2b99-857b-4083-a92f-36f182326bc7">Value(s) for Anatomic Location of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a0007a22-85ae-4827-a0f6-8e9bc75e16c6">$TargetSiteMod</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6bddb6e6-83a3-4167-b6f2-b5de271ed0bc">Modifier Value for Anatomic Location of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_380b1baf-5ace-4c43-b1ee-b425172579c8">$Equation</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2aed46c6-eac2-496c-882c-8953fb18a4fc">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_311f48b5-37c5-440e-8687-ff61aac2c7e2">$ImagePurpose</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0291ccff-9df5-4b97-a117-5f245e2d5d4d">Purpose of Reference for an image used as a source of the measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9972894f-aa6a-4168-83c4-0a734f412a88">$WavePurpose</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_82836268-0d2c-4de6-823f-d567f7fc929e">Purpose of Reference for a waveform used as a source of the measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5b3fff08-495a-43d7-8d44-8a00cb2be52b">$RefAuthority</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0a69d6cd-aaed-4021-8451-c1abe771282d">Bibliographic reference or authority for statistical properties of a reference population</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_332e3c5f-951e-4610-96e9-d9e7281fcb11">$RangeAuthority</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5fef43e6-99a3-40cc-b156-c9054b6db484">Bibliographic reference or authority for the normal range of the measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c441e1b9-7b0b-4e20-b439-5fb3657634c0">$DerivationParameter</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c55737a4-e74a-495a-a5f0-a2ad15221e59">Coded term or Context Group for Concept Name of a derivation parameter</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2e779ad8-08f2-45ac-9c31-29162f80ae8d">$DerivationParameterUnits</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_76ba2922-f81f-49d9-83b3-8ef04f67c183">Units of derivation parameter</para>
                     </td>
                  </tr>
               </tbody>
            </table>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_ab8fefe1-5cfb-4d98-bd8f-473072340e65">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_ef0dbab2-a679-4f50-95d5-3f82597e6279">
                        <emphasis role="bold">Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_a17f8f3a-4c87-4b2e-8c92-218843e7986f">
                        <emphasis role="bold">No</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300">
               <caption>Measurement</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_72040574-5d06-4448-92d3-65d64029aec2"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6dc1a5bb-799d-4ce7-b116-2de6f00399b0">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ada3f541-03e1-4c32-aca3-f7f3d0de93e9">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_34201b00-0939-4acb-975d-63b09c385b07">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_104a2ec7-1391-48f6-b7dc-c5f94a8bb57a">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0699ebc9-be03-4846-a7b1-e8c504fd0ae9">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_40849f85-f55e-4dd9-bc80-7af5c0e2a872">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cd9bf78e-2ee9-47a9-8a55-5cf98072a759">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9856b597-aeef-4056-a98c-25b47f0aabcf">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8e932889-0764-40b5-9f5e-ac3845d6f933">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4b175a93-7c5c-48bc-a5e5-380db6283009"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6ec6fe93-5cb0-4758-8adc-deef5678010b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5fe8320f-931e-4eec-91a8-f8d7ae6d7f00">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_48165cbf-5ff1-4353-9c7b-c05569a0066b">$Measurement</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a6d1fd64-a1d1-4245-8dc5-88b325d3094c">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5ab6a36e-54ef-41db-a7c7-de35a9843624">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5043dfda-6fa9-4044-b601-cb8254bff80b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b0e7cc06-ed22-40d7-ae42-3e8831a76b76">UNITS = $Units</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c515a4c2-545c-43c4-8e41-ade857100b6a">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c94a32ec-4213-4104-9bab-c3f6db880f93">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_689822ca-4490-4ddc-ab4b-fa40eaaf2ee0">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7fdc1a0e-c8a0-46d7-96d9-6c3d8ee2531c">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1b0eebe5-a3b6-4489-8519-995ab0fb2387">$ModType</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_72a99565-a981-43c6-b839-2ea70017869b">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9f7c2de4-d8f4-4da7-b290-b85c8d6374a9">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f35b74d0-e5b2-43a6-aa54-fe99d4fb9621"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e9202f3c-77aa-4877-8002-f52a780921c3">$ModValue</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d1a38665-2780-47a2-8288-b2ac487c6998">3</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b94e2514-7250-42fa-9b08-6b893ad01093">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_30586168-f816-4111-8cdc-f11f95a81d0b">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f382fab9-034b-41e1-aa6f-a7185be151b9">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1b72d8b6-ed15-4a08-9b5b-289774f7cf5c">EV <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=370129005" xl:show="new">(G-C036, SRT, "Measurement Method")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c07f112c-405c-4d23-be39-6a581360dcae">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_838f090d-85d8-4634-8fd7-e2fa6f6039b1">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f6560d8a-8154-45bf-94d2-37153ca9099f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2db623f9-eb56-4064-970f-909c99c2a31f">$Method</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e5425fb-b11e-4ce9-8481-bf4a3747daf4">4</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d6b34bf6-827a-40ba-8b4b-be7b2de154d3">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_04f58196-f7fe-45be-b29e-ae83c4d92fdc">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5542c40a-7059-4932-b225-434e716ad737">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7b90b1fb-e270-4b78-800b-1d187de4e1d5">EV <link linkend="DCM_121401" xrefstyle="select: nopage">(121401, DCM, "Derivation")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ca8df5bb-1433-4349-8f74-72b58b00b6d9">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cda9ee73-45c3-402d-8c97-9b7488003a2b">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dabc7969-5f11-4e95-90a1-c456bcbdb6a0"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4c43c691-50c8-4531-a525-c7ee0892e657">$Derivation</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_842a90c7-9b2c-4e1b-9d86-07032d12440c">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e5831500-d717-4acd-b9f0-e1830aa51c47">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5bcc1fd5-adc6-40f2-9d60-ac63e06e3ae6">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52d994f1-7970-430c-98c6-d6f793b4fc94">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5eb269ab-ac5b-4d94-8a57-65f11a3120c3">EV <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=363698007" xl:show="new">(G-C0E3, SRT, "Finding Site")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_620460a5-326b-427c-bbf4-b91e1aadb9f0">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a5fb68de-67b6-48ad-a052-670d176b1a63">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_721786ea-c21c-4c3a-9548-550c54e19cd9"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5ecabefa-537a-4f14-8b77-f5d7e7abc868">$TargetSite</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d351ac50-bc5b-4990-95e0-590c7c311491">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2ea5b580-7476-4ccd-bf8d-1c4aae332342">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_53959fa5-9bba-4765-80fd-5b7a9880ddc8">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e500ea97-1971-4b1e-b316-09423b1e2458">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_55011eae-faab-453d-89c5-60f2b8e7a403">EV <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=272741003" xl:show="new">(G-C171, SRT, "Laterality")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0961a671-0b3c-4ded-978a-5830e6c0880e">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_27501979-c2eb-4352-a929-85fa10dc148c">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d067a1e3-0284-4cfc-beac-2c127ea50637"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_760eb9f5-5cb5-4415-930b-9df9a996ac58">DCID 244 "Laterality"<!--<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c84a9a9d-404b-45f3-95e6-a0788c85a1e4">7</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9fb178ea-cdaa-40bc-be05-5206fc09fbf1">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_69f456db-3070-400c-bc29-ee9e3e11d64f">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c49d44f8-3d49-40da-a2f4-70949603f29c">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ae97e081-9e86-4c97-90d2-d44ff283b411">DT <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=106233006" xl:show="new">(G-A1F8, SRT, "Topographical modifier")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2ce576e6-dbff-44ee-a636-8edcd0056567">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d790e090-8302-446a-a659-1c295bfc889d">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4031f3f1-b19e-47da-b68d-974b820fddb1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_588bdde1-6eb6-4381-9df6-bebc5afefb83">$TargetSiteMod</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_55fe4e86-cca8-4940-a540-f4671dc0299f">8</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3023b9dd-13cd-4226-8581-b965fcf2707b">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fcd20d74-1731-4c10-a82b-f5f833fd15e2">HAS PROPERTIES</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_43b37530-680e-4a91-b528-d23f15ae3074">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_48f871f5-996a-4c76-9e96-4770562ac907">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5c29e082-0dcf-4fa2-addb-92519d41714e">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_690ef0da-0abe-4c43-909d-1da7dbcdf06c">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fd9608ef-d2bf-4299-ba69-b5085bd20e57"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1724ebe0-9179-4a20-a841-10c211c21038">$RefAuthority = $RefAuthority</para>
                        <para xml:id="para_458c2786-5228-4d78-87ec-e3afc106df26">$RangeAuthority = $RangeAuthority</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_43381e20-6ef0-4650-9d9e-da46ec75ba79">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_daee4ae1-1990-4e4b-8bbb-6b005058e282">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4f26c7f9-c49a-4ca2-8858-5c435b7ba3a3">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3d9d6bef-6713-417b-bf49-7b47aa74b693">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fb72713f-a9f4-4dd1-ae98-b38b33de4880">$DerivationParameter</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a1c094ed-6a6b-4b41-8f22-1d353f747243">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8de34b01-9262-4b03-9511-a5aa39fa4794">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b4775203-ee1a-4b1f-a1cd-4c54d7fe8dab">XOR Row 10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bfcb79da-82ef-4927-9a4f-a996dd7c6757">UNITS = $DerivationParameterUnits</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dd9992da-41ce-4e0d-92fe-86318d362bd7">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_48f7e292-83e6-4fd0-8fe9-5ad09f47f479">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_84f7a34d-f097-4ab4-9090-c41cc80d520d">R-INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_baf0060c-0a8a-4ef3-bc44-0d8b2b551943">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_625ca83b-7a41-49f7-85e3-3438077fb640">$DerivationParameter</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9250282c-225f-47fe-af9d-c8792a8deb2f">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1c647934-4d63-4c9a-b7dc-4d86f52c1df5">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_59c20b99-32ea-4634-91d5-dbe8957d0757">XOR Row 9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7fd8f155-8c00-4238-9d8d-5871d87443bc">UNITS = $DerivationParameterUnits</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_10e094a4-53db-45d0-92fe-b6b6d42d0a13">11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5766072c-5bd3-4569-acf4-6daeb654f73f">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_85e15b2f-722e-41e3-9a73-84710fd3cbaf">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_03dfdd98-b520-4631-86c9-fb0be07aa719">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0dec0e69-4ca9-46b7-8078-b1d9eeea7c9e">D<xref linkend="sect_TID_315" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1d2b6f4b-1493-4e02-aeac-6d3e9879447d">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_aaff5d2c-9786-4aed-a9d9-6e6bcedbb7f9">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d8041e0-b30d-4e10-81ad-3b929b364a05">XOR Row 12</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_70492950-ae80-4731-b562-31b8b1b33f47">$Equation = $Equation</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d2fdd423-32ea-4648-b480-9d09020900f9">12</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_67bae056-7e0e-4030-ad90-6efa9cfe1d59">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d30b8d9-4cc4-420b-aeff-12193d252f89">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6fb0a06f-4888-4155-883e-e2e2a9d1133e">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8dcdc31f-b3d8-479f-b25f-67ef7ecf2501">D<xref linkend="sect_CID_228" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5b8bd265-dec6-4c3a-a698-b195890ca5e8">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a76c7edf-04cc-4626-9af1-9fcc2f783890">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f5c175e6-a7af-4f17-ac9b-54f386e648ea">XOR Row 11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5a623f5b-403f-4444-a751-c3f205c9f538"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_770d16b5-21b5-4887-96bd-6aeaf6afd2c8">13</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_10c8009f-cdf8-481e-a705-02fa7087fc41">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b3918619-21e2-4ed1-b694-45f56b4953aa"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_161efed5-07f7-4bc4-9c2f-baffaed7e8f1">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bf78b3b7-4ed9-47bf-88a9-18efa573270c">DTID 320 "Image or Spatial Coordinates"<!--<xref linkend="sect_TID_320" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e1a45d45-0533-4a14-8fba-e85f2a151d8f">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_72e4002f-993f-410a-99d7-d699a37f8340">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eaaa3c9a-40ef-4fa0-82e2-39369442ba24"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_22d6c3ff-aaca-45d7-b0a6-d0109f903293">$Purpose = $ImagePurpose</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0f1f348a-5796-4a87-9ba3-f2889749259b">14</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_451e74d0-aac0-48d2-99fe-d88c8f19c95e">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_efe5adcc-e9c9-4812-badf-d6d44e61aa4b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c40f07c9-ca79-4b2f-8065-7325242d588b">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e79da970-e41b-4528-b581-450ab8af39d1">DTID 321 "Waveform or Temporal Coordinates"<!--<xref linkend="sect_TID_321" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c274ef43-d146-4065-9802-fbe6c4f48ca2">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3e6d8f0a-39ac-4c87-972c-e242109f5fe1">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8ea7f370-a961-4816-867e-e6d3d41763d2"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_594b4882-e970-47db-9edb-c64c94f3421c">$Purpose = $WavePurpose</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c7aa30b0-48fa-47d3-b01f-526dbfd309fe">15</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_de9abf82-2580-4ed2-b827-66fd38bd0bb8">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_248194c6-08ea-4081-a987-67ee3386cfdd"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e5aca031-f439-4c73-93e7-04a9349d9f57">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_03e11b2f-4ca7-4965-a63f-d424952bfc53">DTID 1000 "Quotation"<!--<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_41f7b608-3448-4e63-af78-f8b995bdc738">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0dcd4a6b-302a-4a27-8895-a530a154ee07">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52ef5229-812f-4efb-ad81-46d5454f112c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f5a0cce9-8350-4e8f-80ed-f5d55206196b"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4a041534-7087-4287-9602-af9928c73c30">16</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_56a190fb-cd34-40de-8d6d-4eec35958b13">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d897d7e7-1ced-4087-b3ad-7137de920360">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d1d9895b-c478-4112-8afc-816cb4b3edd1">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8a836245-f544-4e0f-ba7f-14532c3196d7">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_92ace882-b4c5-4d3c-9240-e5779a2238f9">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2562d454-f655-49a8-8fab-182e76a9f03a">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_35dfcf1c-1a3c-4ddc-b49c-1bfbc9d51050"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b1a89c74-4147-43f6-ad3d-ea013444ce4a"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_26c23e39-a9c1-4701-98a6-106282354629">17</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cc5a3807-a0c7-4d54-8052-d82df186390f">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8cac7bd7-9c79-4ce1-a84f-242d236c7ef0">HAS OBS CONTEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d5d1c26-bcdb-47f2-ba7b-63bfc34170ef">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f59c744d-2c77-475f-875c-a9dd0dd3e259">DTID 4108 "Tracking Identifier"<!--<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c39a5a76-3780-4adc-9520-3a00ee799552">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_35798212-6c86-4213-bba5-94e3d4b03a09">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b38af8cb-5096-4c9b-a325-9a5b55dc1a3a"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fd31b1f0-0ee9-4a19-8749-73a389d7cd88"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_673b4f2b-1fd4-42c3-be28-2691c914334a">18</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f93ce24f-3cce-44b5-9f68-d29922a19e46">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8ec8b82d-6fae-4ff4-b67a-531effecdc45">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d6706747-38ef-49db-a6a8-2751edfb08d9">COMPOSITE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f828a919-5902-43ad-b84c-7be92deb8eeb">EV <link linkend="DCM_126100" xrefstyle="select: nopage">(126100, DCM, "Real World Value Map used for measurement")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a8a2b73a-12e7-4d5a-8325-a62f25249248">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8dbd6f45-fb6e-4182-b964-a80797c29990">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_202d1931-abc7-450b-bfc3-5abc88d95a7f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9054b3b9-cd7b-4eb5-9a63-a9b44b2200a7">SOP Class UID shall be Real World Value Mapping Storage ("1.2.840.10008.5.1.4.1.1.67")</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_34625822-8896-42ed-b521-0531c03174c9">19</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_110b18ac-27da-4e25-b8d3-5e3fb7964492">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_edce7dc5-cb16-4585-9226-e1e35e81564b">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a690c6ad-8e82-4829-bc89-20e99aec550b">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_183a95cc-a257-4743-9765-b8b2e889ae16">DTID 4019 "Algorithm Identification"<!--<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e0678672-8b48-4285-b9f3-796f47903fcf">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c8517cbc-dbf3-44b5-bc57-8782ac895159">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5005f9fc-75ba-42bf-a3e3-74b3161efaf5"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_be8acca7-0043-4ec7-901f-46c966708429"/>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_c568a2c1-03b8-4849-9910-d9efaf957365">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_effc493f-84f6-437c-84af-31ff7bf9c06e">Rows 2, 3, 4, 5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_33fc3488-12f8-4222-ad96-24b55739f20d">The HAS CONCEPT MOD items allow the explicit definition of terms for post-coordination of the measurement concept name. Additional post-coordinated modifier terms may be included in a SOP Instance based on this Template, in accordance with section 6.2.4, or as defined by Templates that invoke this Template and explicitly define additional post-coordinated modifiers (e.g., TID 5203).</para>
                     </td>
                  </tr>
                  <tr>
                     <td align="left" colspan="1">
                        <para xml:id="para_fcb505ed-af0f-4b3c-a679-ff3afdfa0d41">Row 5</para>
                     </td>
                     <td align="left" colspan="1">
                        <para xml:id="para_eb15fbee-f367-4d74-9be2-986aab9259f2">Finding site may be multiple when a region of interest spans multiple anatomical locations and there is not a single pre-coordinated code describing the combination of locations. E.g., when a maligant, inflammatory or traumatic process spans actual or defined anatomical boundaries. There is no requirement that the multiple locations be contiguous.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_77cb86d4-242d-4dc3-aae4-96cae1a4324e">Rows 9, 10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a50d2d4d-b98c-4f68-8e87-61e2fad1c693">The INFERRED FROM items allow the specification (by-value or by-reference) of numeric values that were used in the derivation of the numeric measurement of Row 1. The nature of the inference is not explicitly conveyed; it may be implicit in the Concept Names of the measurements. Inference by-reference is valid only in SOP Classes that permit the INFERRED FROM relationship by-reference.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f8478bcd-4ae8-41d3-99e5-3029ac1c531d">Row 16</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8adf7435-8928-478a-a82f-a4eabcc8d850">Equivalent Meaning of Concept Name allows the creating application to specify the preferred composed concept name representing the measurement and the associated post-coordinated concept modifiers. The concept modifiers may include those specified in this Template, in a Template that invokes this Template, or at the option of the creating application in accordance with section 6.2.4. This composed concept name may be rendered by a display application.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_228b5e1b-b7be-434e-a77a-56dd1279b471">Row 18</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a7b31254-30fb-4b6d-9c23-60fc0150cf6e">Row 18 is a reference to an RWV that describes how measurements were made in units that differ from the stored pixel values in the images referenced in Row 13. E.g., for a PET SUVbw measurement, the mapping from activity/concentration units in the referenced image that was used (and which may be reused for measurements in the future) may be encoded in a referenced RWV instance. This reference overrides any reference in an including Template (such as for a Measurement Group).</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>
       
       <section label="TID 310" status="3" xml:id="sect_TID_310">
          <title>Measurement Properties</title>
          <para xml:id="para_b202a14b-10bd-4c3a-bec3-c10413e1452d">This Template provides the properties of a numeric measurement, including evaluations of its normality and/or significance, its relationship to a reference population, and an indication of its selection from a set of measurements.</para>
          <table frame="box" label="TID 310" rules="all" xml:id="table_TID_310_Parameters">
             <caption>Parameters</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_4f652606-dba1-4f91-8f25-6b7734120821">Parameter Name</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_3bf810a6-6268-4de8-99e4-2f5608ecce46">Parameter Usage</para>
                   </th>
                </tr>
             </thead>
             <tbody>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_ae37982b-6a97-4797-9a5f-69b1961545b6">$RefAuthority</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_13602846-dd9c-4d2b-bcc7-666813351394">Bibliographic reference or authority for statistical properties of a reference population</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_c9707ffa-6dcd-4983-80f1-a47acc24c1d0">$RangeAuthority</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_da7cc524-185d-4c70-ba8d-771cbd53e7b4">Bibliographic reference or authority for the normal range of the measurement</para>
                   </td>
                </tr>
             </tbody>
          </table>
          <variablelist spacing="compact">
             <varlistentry>
                <term>
                   <emphasis role="bold">Type:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_650b0c54-6579-49ef-b88c-d30a13dba0e0">
                      <emphasis role="bold">Extensible</emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">Order:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_4fce6de9-e5cc-44b6-af4c-1d944dd9d472">
                      <emphasis role="bold">Significant</emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">Root:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_f5ff0b6b-5889-4358-a62b-bdf41dd63910">
                      <emphasis role="bold">No</emphasis>
                   </para>
                </listitem>
             </varlistentry>
          </variablelist>
          <table frame="box" label="TID 310" rules="all" xml:id="table_TID_310">
             <caption>Measurement Properties</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_23335704-113c-4447-846f-22edeb8a6c26"/>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_47971d8a-28a0-4dba-b342-7ce1feb7b0bd">NL</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_756dd63b-bde2-4482-808b-d7c3b9e9af39">Rel with Parent</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_3dce1869-ab1d-4ab9-aa13-7faf332a0c5b">VT</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_dcba70e0-7129-4a42-b78d-aa9b5f9871db">Concept Name</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_ab7585df-a953-4c60-aaa2-8ca62d57a6e9">VM</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_5e5c1058-d662-47df-a5e7-1e341c2976f2">Req Type</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_aecfc93d-a9b7-4735-88f3-7585e782ebe4">Condition</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_b8b6af6d-6706-417b-916e-f07e26d1f5a2">Value Set Constraint</para>
                   </th>
                </tr>
             </thead>
             <tbody>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_7ccad4d0-df38-44b1-8ca9-e20365aedeb1">1</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_65a9f2fc-3ef5-49c5-95b9-927e4f13d763"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_4dac77b6-6ad2-46da-94a5-99dbc42986c5"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_d49a28e1-1630-426e-bd4c-4e703e7ebb36">CODE</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_1d03fdd9-fb1a-4b4c-9100-9fef8b0d7c5e">EV <link linkend="DCM_121402" xrefstyle="select: nopage">(121402, DCM, "Normality")</link>
                      </para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_c58f0f20-1afe-4ef2-8835-ce731f1aa45e">1</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_1abdeaf5-4a75-40d0-bf09-954b833c740a">U</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_76a0ba33-fc5d-4e03-96f3-5a959f4e4f29"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_4ec93760-7cea-4da1-9ba0-567047563b2c">DCID 222 "Normality Codes"<!--<xref linkend="sect_CID_222" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                      </para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_b429636a-f7b1-434d-9e9b-b042ef1c2336">2</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_98d869a4-c3fd-41c5-bea1-80ef78dc2b59"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_347f958c-06b6-4f1d-a957-3bba62397468"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_4b49a6f4-1a18-4b3d-8ab3-3a433124a2b6">INCLUDE</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_c7839607-5f75-46dc-9273-3c2705274a80">DTID 311 "Measurement Statistical Properties"<!--<xref linkend="sect_TID_311" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                      </para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_0d6e2925-e4b6-4c4a-aeb1-1e1739e61742">1</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_82223977-1e06-4433-a99c-69f22ff29084">U</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_d239fdb1-86d2-49a8-aea5-9f89c5b39700"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_aa657165-6119-459d-9415-52735f28d556">$RefAuthority = $RefAuthority</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_7392baff-8ccf-461a-851c-f934e7a9a680">3</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_b2523f9a-fc11-4791-81a9-c8f2d16b5919"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_0ec22452-e6a7-4843-8b6d-a6d34bd6b703"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_3c8d9412-3f01-4d53-bac8-1eec16cab9bd">INCLUDE</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_538b2317-fc40-460c-a920-a881397aaee9">DTID 312 "Normal Range Properties"<!--<xref linkend="sect_TID_312" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                      </para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_6a6b8496-2a37-4fee-9d8f-eecaddb3019b">1</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_8de59858-657d-4bee-a131-f3efd056e062">U</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_7bd994f9-cf59-4e75-b73a-fb227d6c41d7"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_3b6e608e-051b-46f6-a298-a85b82d6308b">$RangeAuthority = $RangeAuthority</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_4f18e592-74a3-439d-8b93-d7715b17b1e5">4</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_05cfc679-dca7-47a9-b7c6-479e0db0d04c"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_2148eee7-9537-4a4e-91af-32d4376f1200"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_7af77b04-bb16-471d-ab96-b03b611af612">CODE</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_9e78df9d-f1f1-4a63-be33-bb179d44985c">EV <link linkend="DCM_121403" xrefstyle="select: nopage">(121403, DCM, "Level of Significance")</link>
                      </para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_5fcc90a8-59ba-4599-8015-c2dd4c96be54">1</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_83e7a9ad-043f-4e06-94cf-25826a51f82c">U</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_cb182b2e-157a-4990-9323-3ed0dc80cbb9"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_2a24e6ef-dc1b-4438-887e-9b0a0597b858">DCID 220 "Level of Significance"<!--<xref linkend="sect_CID_220" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                      </para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_6138fed8-8b75-4389-b2dc-9021ef93017a">5</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_18905db1-290e-4dec-acad-66f8d331cf64"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_95111ab9-147f-4d79-b9d6-d3540af77646"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_69e9b6cc-9b2a-4cf3-8183-4a3341024624">NUM</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_b3da04f6-5b0f-4ea2-890d-455618300548">DCID 225 "Measurement Uncertainty Concepts"<!--<xref linkend="sect_CID_225" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                      </para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_282a4935-d59c-4935-9554-fef28aef6acd">1-n</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_b0caaeaa-8329-4e8d-8729-0b57fc2ee420">U</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_f0e411bd-34e7-4c29-ae4a-a14f94314bdb"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_2562aa66-34a2-480d-b8ef-41fb54e7886c"/>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_d47ddc40-017f-4777-bdf3-8d25e90e34ae">6</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_e72fe33b-ffaa-4941-854c-186ec9afea64"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_8b361f3d-a797-456f-8ece-151662c84c83"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_0b1f1108-aaba-4930-a6f8-4bfc873acfb1">CODE</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_f95db2dd-f21a-4778-9ea7-3df78d5b79e6">EV <link linkend="DCM_121404" xrefstyle="select: nopage">(121404, DCM, "Selection Status")</link>
                      </para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_0e2b633a-39f0-4a9e-b863-6bf5a85c7971">1</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_bc3f937a-c7ab-467f-8698-1cda8b48d3de">U</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_deaf6350-62b2-43be-9eab-1172028028f4"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_10f7ba09-149e-4f29-91c0-4b08edab21ec">DCID 224 "Selection Method"<!--<xref linkend="sect_CID_224" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                      </para>
                   </td>
                </tr>
             </tbody>
          </table>
       </section>
       <section label="TID 315" status="3" xml:id="sect_TID_315">
          <title>Equation or Table</title>
          <table frame="box" label="TID 315" rules="all" xml:id="table_TID_315_Parameters">
             <caption>Parameters</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_022b1127-2eaa-4338-87da-370ce03dbe39">Parameter Name</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_c3899c9b-496b-4989-a38a-2bfb6609250b">Parameter Usage</para>
                   </th>
                </tr>
             </thead>
             <tbody>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_00cec662-0515-46ea-9727-64fc60ccbc90">$Equation</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_eb6ec831-287a-411a-84d9-890a7fc73acf">Coded term or Context Group for the equation or table from which a measurement was derived or computed</para>
                   </td>
                </tr>
             </tbody>
          </table>
          <variablelist spacing="compact">
             <varlistentry>
                <term>
                   <emphasis role="bold">Type:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_c2d93ebb-4d44-4f36-827c-ee2003dfd620">
                      <emphasis role="bold">Extensible</emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">Order:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_4d3b03bb-dfb7-4ff1-bb12-abbffbb50c5d">
                      <emphasis role="bold">Significant</emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">Root:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_d66cf6b1-1530-4158-97f1-1c2c1f54f60d">
                      <emphasis role="bold">No</emphasis>
                   </para>
                </listitem>
             </varlistentry>
          </variablelist>
          <table frame="box" label="TID 315" rules="all" xml:id="table_TID_315">
             <caption>Equation or Table</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_5b4d11e5-0a52-4d57-9936-dc79c759ff45"/>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_94bf9d54-3a4e-4727-807d-22f0a304d282">NL</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_b99d200a-5cae-4c20-928e-432ae7feb6c9">Rel with Parent</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_ee98f045-23f2-4c52-97a2-310d03674c88">VT</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_bc8e89aa-c2f6-40a6-a9be-049b341eb2a0">Concept Name</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_7202f73d-ff89-4431-8e41-8cec9ad1767c">VM</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_2b5de4da-ee22-4023-964a-3dc5fa6ecdc2">Req Type</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_ce8955bb-3aac-4474-9ca9-daa0a1eef2b2">Condition</para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_c5072ae0-9408-4857-90b5-4df3e9e4dd68">Value Set Constraint</para>
                   </th>
                </tr>
             </thead>
             <tbody>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_05b5df5e-b693-4672-8972-68c53a0f7205">1</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_13aaa9e4-a064-422b-bf90-ea93800ed88e"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_bb94d513-9cb5-443d-b4ce-e9356a924571"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_7c7f4c86-7311-454b-a9e8-da8b9f1d944b">CODE</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_ead7bbb5-40d4-492b-a69a-70918818ac4d">D<xref linkend="sect_CID_228" xrefstyle="select: labelnumber quotedtitle nopage"/>
                      </para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_0a738de9-4eca-4eb1-a51f-ad2528939953">1</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_a969ba15-8341-480d-9c0a-494d7e1f4df3">M</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_79cd1407-c3c7-4c32-8e68-eefe815a425f"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_6350f044-da92-4295-b06d-90d154a1b923">$Equation</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_ab22dd8e-1b4e-4251-b02f-966c6ab3d2e4">2</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_cfbb25c6-8496-487e-9467-e56c2d2889a9">&gt;</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_4cd06b5f-90d3-4cbb-beb2-dd38d6f36c4d">HAS PROPERTIES</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_96c89d4f-49f4-4e86-9333-77f7b37b3808">NUM</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_0961dd7f-6d32-41da-b2d5-5a700993b4ee"/>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_297e1242-af8b-4e10-97cd-2af7a9c07dd7">1-n</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_7904d5d2-05fe-43b9-a3a3-5eb31566c864">U</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_5eff3afb-0411-48cc-9da1-5e9b1de09d3c"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_bba6b0b6-1a07-4567-af73-0cb5fe0ef936"/>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_c165c8b3-24d2-4096-8bbf-14f8e04f8d9e">3</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_6c4ec19b-9f82-4483-8605-c14fc7d7ac50">&gt;</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_4fd60428-6226-4d94-99b9-17d5d691b1b3">R-HAS PROPERTIES</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_0bdcd2bd-4def-4612-930d-4d5c3333b3be">NUM</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_f4570099-0851-4f27-95e7-85f4b4a7900e"/>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_9f6f5095-5920-4d05-a45d-7349ad334dff">1-n</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_062b197b-cc13-4a31-8ffa-026e7534ed6f">U</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_940dd101-ee7e-4bcd-97a4-04b7424593a9"/>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_eabced23-b962-4bd0-85e0-a7bec4e50247"/>
                   </td>
                </tr>
             </tbody>
          </table>
          <para xml:id="para_97645d4b-b531-4f06-bf61-dc015d3b4786">
             <emphasis role="bold">Content Item Descriptions</emphasis>
          </para>
          <informaltable frame="box" rules="all">
             <tbody>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_b6ff6860-49cc-43b0-b2eb-b180629cdfa3">Row 2</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_a4b30823-1179-4151-90f9-ae2fae8da270">The HAS PROPERTIES allows the specification of the numeric values used as input to the equation or table identified in Row 1.</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_79a49f12-4c17-4f6f-bab8-fe071597650f">Row 3</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_a19ca85b-97e8-4830-a4bb-9da818cd0d8c">The HAS PROPERTIES allows the specification by-reference of the numeric values used as input to the equation or table. This row is valid only in SOP Classes that permit the HAS PROPERTIES relationship by-reference.</para>
                   </td>
                </tr>
             </tbody>
          </informaltable>
          <note>
             <para xml:id="para_286190c5-0329-4b76-a125-15b932628e70">For example, if Row 1 identifies a specific Body Surface Area equation, Rows 2 and 3 can be used to convey (by-value or by-reference) the Patient Height and Patient Weight numeric measurements used in the BSA computation.</para>
          </note>
       </section>
       
       <section label="TID 1419" status="3" xml:id="sect_TID_1419">
            <title>ROI Measurements</title>
            <para xml:id="para_45f14227-f80a-4f1f-9af8-d035a27897e1">This Template encodes measurements for some metric, e.g., density, flow, or concentration.</para>
            <table frame="box" label="TID 1419" rules="all" xml:id="table_TID_1419_Parameters">
               <caption>Parameters</caption>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_292e329e-f8e1-4947-8826-161d191fc0a2">$Measurement</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c1086196-6daf-4d40-929c-e7e9df6fc186">Coded term or Context Group for Concept Name of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2e51f23c-3bab-4711-b50a-6034423cfdb8">$Units</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0cfc2c35-e830-4881-a438-21c1b8707ce1">Units for the measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_99c17fad-62f9-4561-884e-0086ca33500c">$ModType</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8be7b402-4bf4-4d2e-a22b-7ffb61748bb5">Modifier Name for Concept Name of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_81b0a409-6835-485d-afb4-d7d80f19616f">$ModValue</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a421c619-8c68-49ab-8b47-71afc81a72ae">Modifier Value for Concept Name of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d6cdd202-bcba-4a46-963b-a2c274967bfc">$Method</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_97c24ca3-30d1-4c54-8472-cb9ec48aba5b">Value for Measurement Method</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dd549387-7bfb-4555-851d-dae938d0945d">$Derivation</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2fbe939e-284a-458d-8599-037b56ddb53d">Value for Measurement Derivation</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4e5089ea-4435-4f68-ba60-3ae02c5599bc">$TargetSite</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f78d7296-555c-439e-93ee-d1185262bf92">Value(s) for Anatomic Location of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_50cda1d2-9060-4344-b3c7-e48177de7bd2">$TargetSiteMod</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ebbb922b-40fc-4c82-872d-ef1bef3bc79a">Modifier Value for Anatomic Location of measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d1ccdf05-29b4-4ddd-a271-8344bbd908ea">$Equation</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4ee80037-6d7e-4ab2-aa8b-4a5a3b180d78">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1b729cc2-444c-4c52-b1cf-3cfb1e11025f">$RefAuthority</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a389270e-2a12-4154-be56-41a520fb8ea5">Bibliographic reference or authority for statistical properties of a reference population</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bd1312d4-18f4-4622-a662-5f4e8935ca07">$RangeAuthority</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d71bbd51-faee-4dad-aaa0-710884671a33">Bibliographic reference or authority for the normal range of the measurement</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2d133fb0-d88e-45b2-bf47-998020241f44">$DerivationParameter</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_49750e56-0ad3-4012-8fc3-2432de731396">Coded term or Context Group for Concept Name of a derivation parameter</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e0ccbe3d-5f65-4202-9cbd-157b3ac87770">$DerivationParameterUnits</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4d75ae00-8189-441f-bf65-a916c32e2f1b">Units of derivation parameter</para>
                     </td>
                  </tr>
               </tbody>
            </table>
            <variablelist spacing="compact">
               <varlistentry>
                  <term>
                     <emphasis role="bold">Type:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_44828fcb-c085-4493-9fcb-fa75040f6acb">
                        <emphasis role="bold">Extensible</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Order:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_b679eae3-53f0-46ea-a58c-2f88a99d2741">
                        <emphasis role="bold">Non-Significant</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
               <varlistentry>
                  <term>
                     <emphasis role="bold">Root:</emphasis>
                  </term>
                  <listitem>
                     <para xml:id="para_1cfbed6a-4e51-4ec6-8b85-4dfff632cb9a">
                        <emphasis role="bold">No</emphasis>
                     </para>
                  </listitem>
               </varlistentry>
            </variablelist>
            <table frame="box" label="TID 1419" rules="all" xml:id="table_TID_1419">
               <caption>ROI Measurements</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_12836944-553d-4d38-87cf-18a10f4027ec"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_46517370-7769-4cdf-86c6-7aa492dce62e">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_14515a82-f650-424e-9e85-f2ad8e617f3d">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_584e0384-4e44-48b5-b820-cae6f89883d1">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8724753e-a9bf-4505-bfac-cbe35b18ebd7">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_24ee3e66-d99f-43cc-b1ec-cab5e2af1d1d">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5514d345-0451-4361-bcbd-1ab9d403eca6">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_35905e7d-015f-4650-abc7-c4f3882b808a">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_613db39e-b4fd-4834-9441-3726f59ac635">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ae7b9269-2ca6-4552-99b4-f2f15c58e179">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5a3e9de5-1c2f-4741-b492-d06585fb1730"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9eaf09fa-7ce0-4a4a-91fa-bcce52a71005">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b3f687a3-341f-4e27-bdae-8e1ac620a4ad">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fb22d47c-a08d-40b6-b3a3-05e66fc56fdc">EV <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=370129005" xl:show="new">(G-C036, SRT, "Measurement Method")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e7120133-6db4-4377-8edf-a4d5b927e51a">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c3f244dd-073e-4e7b-b05d-1215e3d1f55b">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2887134c-e284-416f-8d36-4f558fbededf"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8b83b65c-fa42-46a3-bab9-2efb92d1dc03">$Method</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4bc5fd33-d0ae-4efc-aa0b-b5fec64992b6">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2c668a93-713f-4294-a910-7da8ed643d00"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_daa1f94d-d1ae-43d3-b784-92f7ad907f3e">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5a63e8e9-aa0c-4fc9-9d92-b8dd7ea0291c">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_584ba5ab-3d7b-41a2-a697-bf568fe76bae">EV <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=363698007" xl:show="new">(G-C0E3, SRT, "Finding Site")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_da6d9f63-86d4-4acf-ab99-73ce14bf2f98">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_08c19a43-a378-44a6-8bcc-9f18dab1f892">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_31e78aa1-e7fc-4dae-9fcd-411264cbedb8"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52c2fddf-e989-48b8-a4e7-f2ce3925b77d">$TargetSite</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_093528c8-e998-4869-a9a0-53a289bab84a">3</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c4d07301-451c-4f2f-8b84-156dcd7fd81f">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d6786ee5-64af-4420-9100-0438a6ce02d8">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_29271ac0-dbb2-4855-a0ec-5aeb06c3ca22">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0335b521-2205-47a1-8907-af8d5dba043e">EV <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=272741003" xl:show="new">(G-C171, SRT, "Laterality")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_629dc65a-d040-4937-9fdb-4d8e9ad38f71">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4380d7a9-114f-4aa2-9bbf-0c28197dabba">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c7b0f6b6-53f6-41ba-b8fd-24a95745b19f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6cea5814-0e39-4d1e-ae56-2399fe33d84f">DCID 244 "Laterality"<!--<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_629818bd-201d-42a1-9a89-22ff48e20fc5">4</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fc2293c7-f166-457a-a91c-52278831d46e">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e06204a-3161-4e28-9a28-50c76d37c539">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_910a542a-d9e1-4d63-9307-85a93581ea9a">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fe89f56e-016a-4523-a21e-a0211ae31af6">DT <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=106233006" xl:show="new">(G-A1F8, SRT, "Topographical modifier")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f43b8a67-b5ce-484c-8e25-38ce72164744">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5b6322dc-62b7-4384-a285-d40f84747c24">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_96b31cb4-5502-4bf9-aca1-8c3069ee686c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8a6647a0-0daa-4be6-befd-a8bef42728d0">$TargetSiteMod</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_42dae226-407f-46d6-990e-4a3856d5dc2c">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3575aa5e-eba5-4a0a-9e81-7c84db2cfdb5"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d3fd739c-416d-481b-8a3f-894f2e240d0a"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5f540b40-5ed3-4a2b-aeba-aacba2b72a7a">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_451f249b-f32e-452c-b341-b9c68d09a547">$Measurement</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6ca4a420-efd5-48a5-9a61-2b9bfc954a82">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1f6fc21b-ac48-4e10-a7ea-d44dd68f0ea8">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8e7af36f-02f0-4ae7-9a77-7102cc7d851b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d7afdc57-827c-4ac5-9c2b-5ce3c6ddebd7">UNITS = $Units</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7b85e119-679b-4716-b873-b3938706de2e">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d0360226-e798-4c57-98e3-c0227a1904bf">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4d4ea7f5-02e2-4e4a-8d95-172c68048ec3">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f09bd16e-6c86-4719-bcce-af1bcd7efacd">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_69f80ec7-f182-4ee1-b80f-48d4616ebb42">$ModType</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7ab28def-a137-4fbc-a8e7-7954a74dba88">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d2c2e35d-0ed3-42d1-9eb4-26394898748c">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bdaa55be-7339-4e00-96bf-f2dcb26497d7"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_565d3344-f84d-43fa-a753-12479c89cf3b">$ModValue</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2b3fb12f-7614-4cc6-a599-27aaa3d72372">7</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d46d3481-580d-4164-a6a7-92d80bbac92e">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c0bd889d-96de-418a-af3c-946da2b2a26e">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_92d08bfb-e614-42ae-bc6f-66ae10bb4e79">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c2df53d8-5cbf-41cc-a7c2-dca790823367">EV <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=370129005" xl:show="new">(G-C036, SRT, "Measurement Method")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0f8d3f1c-894a-4a6c-9c7f-e4fdc373c9b8">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6006b8c8-0e2f-4ba8-a01c-a5874c2dca91">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_537de7a7-09df-433f-87c6-687c2da54c21"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7050a109-584c-4b43-82c0-0df1041d7940">$Method</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_545cfcfa-e38e-4fd1-bead-ddbb884fee6e">8</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_307af66d-3860-4503-ae18-7755280b0543">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_45021fbb-4fc1-44ea-97ce-534c10e2062a">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_da90e240-f344-45a8-b00c-9266b11070fb">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b000c69b-a577-4621-9840-e21bce9b1293">EV <link linkend="DCM_121401" xrefstyle="select: nopage">(121401, DCM, "Derivation")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c8498272-5d5e-4b31-9a04-f9339d12f9e2">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_04b39d7f-d9e9-4a3e-9589-226c305d8d1b">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4607664e-7b7f-4b0d-9368-ce9da880fe47"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3063fb8b-3a89-4e85-a5cb-df37724dbf7b">$Derivation</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0a846a6d-404f-4301-b21a-4fffee56f234">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e9828437-9fb9-444c-999b-7ddd009e9f10">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2a17c134-3059-4e85-b114-215c88bd59d3">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_863a473f-6f21-4572-a14e-b4478b964f54">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_14233ab1-3db1-4fc1-b7e3-fd2f72413f72">EV <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=363698007" xl:show="new">(G-C0E3, SRT, "Finding Site")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e1641d8c-a893-4518-a565-f354fdcb917c">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_be39d380-ad2b-48c3-849d-e7c1648d67d9">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fb834fbc-19a0-47bc-be56-ea5717a1d508"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_36bb35e2-a584-4a5d-9a72-3c1341bb130f">$TargetSite</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dec009ac-d9b9-4e31-aa7d-9e5627f3f56d">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e17744e9-8428-464f-ad65-7c6c9d55de59">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_93afb2b4-fb3a-404e-ad7a-8904e6801e85">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9ecab110-105d-4383-974f-adaa77aa8413">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ef4cc1fc-9c82-4bc8-b9a3-a54075d9fb10">EV <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=272741003" xl:show="new">(G-C171, SRT, "Laterality")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e2661d8d-b1f2-49d2-9b73-9a9a021bf1b3">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1afac7f7-00f5-4f25-8cb3-241bc5bcccb6">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_175dd4ae-6b47-451a-a5ea-43bf488169fa"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_13e42fdd-4626-436d-816c-332d10ff6c9b">DCID 244 "Laterality"<!--<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d9eedb2-6336-4f41-9e37-0dcf0ce741ad">11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d538f458-a702-4b26-985a-7f0a2675714c">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_169ea879-9647-46dd-897d-18b331003369">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d3de1329-1c9c-4668-a1c5-269bc82f028a">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4ccd7ed8-579e-4a54-aac7-2832ec41fad7">DT <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=106233006" xl:show="new">(G-A1F8, SRT, "Topographical modifier")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_71cc3114-d78a-4f1e-bcbc-2dcd1e7b869c">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_14ba85ed-8299-4a14-b5ac-367ffb0c5598">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a53b99b3-acca-4cf0-98b0-301279b5d032"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_690a24e4-f854-4982-933b-c52f4cca4066">$TargetSiteMod</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2f06ec4f-00e3-42b7-abfd-679f469a5165">12</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5100111a-223d-4421-acbd-87b4fd4d2e5d">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_254ced2f-5b0d-40b7-9f5d-b8e5f494aeae">HAS PROPERTIES</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1a930a3d-e474-48f2-903a-4d4d5c2e9192">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ff589ed3-47d1-4278-8441-16d271a9e501">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_17b8cd03-d838-4fe3-98b9-3bd0ce86655a">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b7e16452-8d42-4bf1-b89d-0f7abebbe9ad">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_06d79ff1-9e86-4521-851e-3bae7f8bb268"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ceb6ba4c-0f6a-4ede-916f-42b8feba59fa">$RefAuthority = $RefAuthority</para>
                        <para xml:id="para_25959efe-8596-45d4-95a7-37f3509fe934">$RangeAuthority = $RangeAuthority</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e6c1f29d-81ac-4870-92b8-db01871b0246">13</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f5256e5f-5c7c-4501-ac99-280f111f0aa0">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_84992584-15be-4f27-9f0a-36230954ccb6">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aee1334c-0155-4e49-980c-82f6c3ce419a">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_327316fb-f2f3-4307-bc02-f8269a7f6b0c">$DerivationParameter</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_42d5ab15-beb6-474f-b6eb-0ee2dd9ef3bd">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cc47179a-5040-441d-9815-82cd18949c7c">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c15e51e4-5088-46db-bb21-ae5a51e11a56">XOR Row 14</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5ae4cd2b-3e98-498b-9aa3-ce5390659bdb">$DerivationParameterUnits</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ae21b7e9-8a3a-452d-9531-330b7ad1eca3">14</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7bc8bb76-807a-4619-8267-3b9f402c24fc">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7518e153-03d6-4188-b282-6d85a67ca1d4">R-INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1bc3e48e-45c7-4769-a28d-68c7057b088e">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a7ca8c32-77b6-4eb9-9868-91e2cf13847a">$DerivationParameter</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_29ff2da8-43cf-4d0a-abad-76a052474a1f">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7aeb9cbd-da61-4d6e-920b-a1c94aa7f214">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_92986de2-b1c0-4e4e-8936-2adc3e8ed31b">XOR Row 13</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cedbcb49-4d66-48d1-b6be-4429a96b9088">$DerivationParameterUnits</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">14b</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">INFERRED FROM</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">$DerivationParameter</emphasis></emphasis></para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">1-n</emphasis></emphasis></para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">??? DCID TBD ???</emphasis></emphasis></para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">14c</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">INFERRED FROM</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">TEXT</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">$DerivationParameter</emphasis></emphasis></para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">1-n</emphasis></emphasis></para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9e3fb6b4-1211-460d-b721-1fd9b68c65c8">15</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_62369d95-cffc-4dfa-b695-b82febf06b69">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_affd6401-c8bc-4cb5-8047-4a3622a89f82">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_49575bee-89a3-45ea-8af0-61f0f07d445e">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_51fa7345-1b51-4e8e-abfa-aa37c0a0eb08">D<xref linkend="sect_TID_315" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c923e41d-d982-429f-8071-1a413d79ad6d">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4b9cae73-9089-43d4-b6de-21a23951d0bc">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4cd4f4e4-94f8-45ec-a882-5f052bbd5f78">XOR Row 16</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_00ff00f9-a860-4d28-b058-9aefd8a3e7b1">$Equation = $Equation</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e658ed24-63c9-429e-bb2f-b5c00c4de5d7">16</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e59562f7-7b2f-4d0a-b3bc-ffbff5b265e7">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8a6ffa8a-0e0c-4fca-9693-1166d06e1ef2">INFERRED FROM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_05abde89-bec3-4758-b156-bee7b486cf67">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bc57352c-79a9-410e-8d77-50b48835c0dc">D<xref linkend="sect_CID_228" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d50fbcf5-cf02-4b5e-a373-0a63c6b62d4e">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8f573b2d-c89c-47ff-a894-7a22136462cc">UC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_60d6c427-5bd0-48f9-a316-7ac191d7de51">XOR Row 15</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ae492543-dfa3-49bd-a7d3-7086071b4608"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_92227394-d937-44b2-81ac-17bbb08e171c">17</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_51716c8a-f408-415a-8c6c-003cf5697b76">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_74d2a03e-c143-45c9-b448-7a7fc10a3269"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4e5d5f73-34cd-4231-b82a-9c173458e066">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_29b516a5-be4b-4286-be90-cbf9cfba6a61">DTID 1000 "Quotation"<!--<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2082260b-ab19-41fd-88e5-177156bafe58">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6ca8536e-12a5-41f8-91a2-25a0e39975a8">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_adb6ca0d-5d6a-40dd-ab59-7114bd3b2f17"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9a4ebb56-b7d7-4cc4-a31b-d522bc272b57"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_789e110b-3b52-416c-a681-c59c1ad0d8b6">18</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_69e9cc28-e33f-46fe-b8d0-f59537a542a2">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a11f9efa-f14d-4b0e-8f7b-f10f288f833c">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_74684059-7f7d-4264-a16d-474ece4c27b6">TEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a6fd50ea-2164-4d61-b701-3d520dc22744">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_bd895bb0-f6ca-4987-881f-e5d116864ede">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c0c12e18-65c8-4b16-9e95-513f10bf3220">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b6440a08-404b-43f0-b696-f5db055cfe47"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d56a9acb-98a3-427c-9007-ddeff4aafa25"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_43243a72-7ca5-493b-b1b8-525778c80f6f">19</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8d8646e7-8306-4bcb-9158-de936280ae74">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0432c3b3-b45d-407f-ba65-15fa59279ef9">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c328fdb4-f088-45cb-92bb-bc01b0d4f1a8">COMPOSITE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bbdbadf8-c315-44bf-af87-de8c15f5704a">EV <link linkend="DCM_126100" xrefstyle="select: nopage">(126100, DCM, "Real World Value Map used for measurement")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f9bcade6-9464-441d-871b-4605105a854f">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_aa8b8be2-7188-4c97-8058-99812a4d73e3">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_26a3be85-1b9b-49f1-9888-6c748050311a"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52e1332e-e1d8-4174-b46a-76e649047ebe">SOP Class UID shall be Real World Value Mapping Storage ("1.2.840.10008.5.1.4.1.1.67")</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_82baac86-e021-4e9e-9542-90304973e540">20</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bf316200-3a4c-405f-b306-c5d6603e85a1">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4377e26c-668a-48b9-a1c3-7ebe00493490">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e47c0719-70ed-4312-9f12-f9e418b68adb">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4497e7ad-0a27-4be9-825c-69839301088e">DTID 4019 "Algorithm Identification"<!--<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7837aad3-2875-4b1b-a7fa-4633c0cdd607">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_32479f30-e53a-4a8b-bad2-bee2ca6799bf">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ce84bf37-0333-4f64-8f0a-cb6f250405f5"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ae471fb7-a381-4676-8800-5f665e47196c"/>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_6e05db3a-3563-4055-8835-7b0dec5c3f91">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr>
                     <td align="left" colspan="1">
                        <para xml:id="para_9a72c975-86b5-4074-9550-01f762a5176d">Rows 2, 9</para>
                     </td>
                     <td align="left" colspan="1">
                        <para xml:id="para_c2e82fdb-2b7c-44bb-a767-9cf24830ec02">Finding site may be multiple when a region of interest spans multiple anatomical locations and there is not a single pre-coordinated code describing the combination of locations. E.g., when a maligant, inflammatory or traumatic process spans actual or defined anatomical boundaries. There is no requirement that the multiple locations be contiguous.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_49b388fa-80c4-474c-aa27-5b2dc3d8cca2">Row 5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2bbde9df-197d-4713-92e6-7058f557fa01">Specifies the metric for which measurements are reported, e.g., density, flow, or concentration. This metric is computed at each sample point (e.g., pixel or voxel) in an ROI (defined in the invoking Template), but those individual point measurements are not encoded. Instead, just the summary measurements for the ROI are encoded, and the means of computing a single value is defined in Row 8 Derivation (e.g., mean).</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4796593b-aab2-43b8-a595-733319ba48d3">Rows 1, 2, 3, 4, 6, 7, 8, 9, 10, 11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9a9d5c86-be02-4dde-a885-7f9b55c2c8ba">The HAS CONCEPT MOD items allow the explicit definition of terms for post-coordination of the measurement concept name. Additional post-coordinated modifier terms may be included in a SOP Instance based on this Template, in accordance with section 6.2.4, or as defined by Templates that invoke this Template and explicitly define additional post-coordinated modifiers.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4dcff747-abe1-46b4-8546-23994df0bdf1">Rows 13, 14</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_68a78026-d9fd-4722-b754-a02bdbbd8c36">The INFERRED FROM items allow the specification (by-value or by-reference) of numeric values that were used in the derivation of the numeric measurement of Row 1. The nature of the inference is not explicitly conveyed; it may be implicit in the Concept Names of the measurements. Inference by-reference is valid only in SOP Classes that permit the INFERRED FROM relationship by-reference.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a9a4d48b-d036-4b6c-925e-9d8e89615cc4">Row 18</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c70535a9-847e-49f6-a9bb-4d16bb29411c">Equivalent Meaning of Concept Name allows the creating application to specify the preferred composed concept name representing the measurement and the associated post-coordinated concept modifiers. The concept modifiers may include those specified in this Template, in a Template that invokes this Template, or at the option of the creating application in accordance with section 6.2.4. This composed concept name may be rendered by a display application.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_02edb578-615f-4f7d-8ea6-ff265da30ea8">Row 19</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_51e1a9da-d95e-46a6-a862-9780cf23241d">The reference to an RWV in Row 19 allows measurements to be made in units that differ from the stored pixel values in the images referenced in the parent Template. E.g., for a PET SUVbw measurement, the mapping from activity/concentration units in the referenced image that was used (and which may be reused for measurements in the future) may be encoded in a referenced RWV instance. This reference overrides any reference in an including Template (such as for a Measurement Group).</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>
        
        <section label="TID 1500" status="3" xml:id="sect_TID_1500">
            <title>Measurement Report</title>
            <table frame="box" label="TID 1500" rules="all" xml:id="table_TID_1500">
                <caption>Measurement Report</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f96ef72-3739-4709-a6f5-d3c609e4ec05"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb663436-d709-454e-ac93-98682212c9f0">NL</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6142a93b-0f6d-44a4-8494-fc3299ba7c21">Rel with Parent</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_81a6fa58-162c-4816-971a-d0a224744ee1">VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_97622db7-889d-46d0-a1c0-605bfed0f4c7">Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_feb517dd-7464-42f5-9f1d-496753de6be4">VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_220e6ae8-5f33-4f58-b426-f41cd8fd2bf4">Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9af3785d-8f23-4d07-809d-5639784468c9">Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80f6672b-b0af-4725-adc3-e4e8c7e83695">Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_96d6cfbb-9f8d-4203-92f0-dc6f05c2d0a8">7</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6ef2d231-13a5-4959-a821-9506f815bff7">&gt;&gt;</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3f15deab-dd23-4d60-83de-dd6a73b90078">CONTAINS</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7ce9f59e-0b11-4f3a-aa05-a88e1aa9c1ae">INCLUDE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_77bd714c-3790-436e-8fde-280daf9850b5">DTID 1410<!--<xref linkend="sect_TID_1410" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9103603-6261-4637-b46b-fa22134536fe">1-n</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_15f776e2-a5af-4ee4-8902-8d861d3932b7">U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d25704ea-5734-4683-8a36-210409afacf8"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a87b6e4f-bced-4eb7-85ca-72f7b53d423c"><emphasis role="bold"><emphasis role="strikethrough">$Measurement = B<xref linkend="sect_CID_7469" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                            </para>
                            <para>$Measurement = B<emphasis role="bold"><emphasis role="strikethrough"><xref linkend="sect_CID_7468" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis><emphasis role="underline"><xref linkend="sect_CID_ccc1" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis></para>
                            <para xml:id="para_378db2d7-b6b1-4bd5-bd55-3ecc1936deb9">$Units = BCID 7181<!--<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                            <para xml:id="para_99508cbb-2bee-4f5b-8816-1d3495eccb3c">$Derivation = BCID 7464<!--<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                            <para xml:id="para_d653b285-fe19-47d0-9b09-d0cec3ff9359">$Method = BCID 6147<!--<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_237b4895-3ec5-42f6-83d7-ca4b9914ce10">8</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_34b0264b-6367-41ef-9ab3-ac6f73e5a926">&gt;&gt;</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_edd197ad-42e1-4181-b741-9f29a3ca83f8">CONTAINS</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_38ae7415-a014-4b38-bba5-90c84f6d89c9">INCLUDE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8276a87d-183b-4ec0-9de3-c5b2ec064c57">DTID 1411<!--<xref linkend="sect_TID_1411" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e654f7db-b58f-4a0c-be26-9679fe2714ed">1-n</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0a9eb71-ba77-4b3c-92b0-20807066566c">U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_637e45d6-6eee-4f3f-9ce5-fb5d384ae031"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a2b0eb06-c798-4882-abec-a2632ac19b44"><emphasis role="bold"><emphasis role="strikethrough">$Measurement = B<xref linkend="sect_CID_7469" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                            </para>
                            <para>$Measurement = B<emphasis role="bold"><emphasis role="strikethrough"><xref linkend="sect_CID_7468" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis><emphasis role="underline"><xref linkend="sect_CID_ccc1" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis></para>
                            <para xml:id="para_d952336b-31c3-4a64-a013-7ff63702a47c">$Units = BCID 7181<!--<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                            <para xml:id="para_9f14bfcc-5741-4404-9156-21acc26e58d2">$Derivation = BCID 7464<!--<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                            <para xml:id="para_7ad66743-b635-4689-8f59-e97ffa3bde7d">$Method = BCID 6147<!--<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e00ee47b-e07a-4063-9295-f00b8f902998">9</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_75af0046-0485-49d9-8863-6ce205f822c6">&gt;&gt;</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aa985cec-610b-4445-b7f1-2ebbab06936b">CONTAINS</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_51feb8fa-c5e0-46a7-afcb-b82dc0f31423">INCLUDE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_afa5de9d-884c-4de6-8af3-0f259624c15e">DTID 1501<!--<xref linkend="sect_TID_1501" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0cc25ff-0ec1-44cd-a6c4-4ba948d2a1ae">1-n</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c07259d-38bc-4ccd-94bd-f6802ad60bf1">U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_87d9dd51-a193-4405-b81d-59c4610661d1"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_17c5d93d-3fbc-4a4b-9dc6-71a477409861"><emphasis role="bold"><emphasis role="strikethrough">$Measurement = B<xref linkend="sect_CID_7469" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                            </para>
                            <para>$Measurement = B<emphasis role="bold"><emphasis role="strikethrough"><xref linkend="sect_CID_7468" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis><emphasis role="underline"><xref linkend="sect_CID_ccc1" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis></para>
                            <para xml:id="para_56c17377-8203-49db-abf1-3e609e9ce931">$Units = BCID 7181<!--<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                            <para xml:id="para_33b0e4c5-3954-4eb8-89c2-efc8fe79d202">$Derivation = BCID 7464<!--<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                            <para xml:id="para_2b135bc8-4839-49ce-9cf7-18949e1ba320">$Method = BCID 6147<!--<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <para xml:id="para_868f2065-cd1a-426f-a9fe-19f831d32718">
                <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fa575819-a7dc-4043-ad84-1d6ce95c8b7b">Rows 7, 8, 9</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5a0d0919-bb63-4e2f-a517-75d44bd1afe1">The baseline context groups defined allow for generic intensity<emphasis role="bold"><emphasis role="strikethrough"> and</emphasis><emphasis role="underline">,</emphasis></emphasis> size <emphasis role="bold"><emphasis role="underline">, texture and other feature </emphasis></emphasis>measurements, regardless of the geometry of the ROI (e.g., linear distance can be measured on volumes, or volume can be estimated from a linear distance), and being baseline, do not constrain the invoker from using other appropriate concepts specific to the application.</para>
                        </td>
                    </tr>
                </tbody>
            </informaltable>
        </section>
       
             <section label="CID 226" status="3" xml:id="sect_CID_226">
         <title>Population Statistical Descriptors</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_260f3f9a-e84e-4f12-9815-d506527410a0">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_226.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_226.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_226.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.31.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_495d93ea-b070-4d7d-8b55-5e9659d768ef">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_5fdc5948-175f-44ba-9b99-8e97df61a44a">
                     <emphasis role="bold">20121101</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_8885a719-4ff3-45c5-95c1-e67cc3e27c10">
                     <emphasis role="bold">1.2.840.10008.6.1.31</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 226" rules="all" xml:id="table_CID_226">
            <caption>Population Statistical Descriptors</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8dda2c66-c65a-4519-aaab-bbcc30876ece">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_874f280b-2cd6-4b0f-95d3-9632422257f5">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f68742cf-1101-4a72-ac35-33a8983d9a02">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_377166b0-942b-41a4-9c3e-bd136e3ccc37">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a28eb77e-0cc2-4be8-9d53-ed7779e78670">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_32267f7d-818a-4c54-b509-32250f751919">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_662abcc3-7849-4eaf-ba73-5212568ac9b3">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371889001" xl:show="new">R-00337</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f5635929-e39a-400e-9074-ced9ace6cab9">95th Percentile Value of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0db5dd1f-30f1-4274-900d-7edea8979137">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371889001" xl:show="new">371889001</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c9a7a0fd-3382-4df2-ac30-7a452acb3cca">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1299358" xl:show="new">C1299358</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_acddadb6-6586-427b-b666-de53a0b100b4">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4ce37e07-f468-4b59-9b47-e642a9d52355">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371887004" xl:show="new">R-00338</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8993684b-b088-4978-b480-91f03bc92699">90th Percentile Value of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9917046a-5f81-4b8b-9243-51d8012d5c87">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371887004" xl:show="new">371887004</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1dc3ac18-5d24-43a5-be88-cc7fdeee7c43">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1276309" xl:show="new">C1276309</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ccdd3acc-e3ca-4d4a-b6fd-5b40a6a0c62a">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_992d22f8-6c65-4bd8-8382-10b9ad3db956">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371917008" xl:show="new">R-00346</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b0436f79-0d15-4102-9f0b-133938494c23">1 Sigma Upper Value of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8790ec5d-4b42-48b0-be9c-0249bf0563dc">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371917008" xl:show="new">371917008</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_885c8656-86db-4a03-aa57-ec4efcc62135">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1299386" xl:show="new">C1299386</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ccb52716-dbce-4981-9169-7d639930a331">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_386a3c6a-721b-4f54-9787-028d006716ba">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371920000" xl:show="new">R-00387</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ec3c2c87-8fdc-45ea-ac38-8fe8867eda66">2 Sigma Upper Value of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2e85dfec-6891-49d4-b616-c244f15255b8">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371920000" xl:show="new">371920000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5b18bcdc-dbec-4565-bc32-7f27e2076e5a">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1299389" xl:show="new">C1299389</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5bad579c-92a8-4e16-8c25-e1db78bc5d1d">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3878ceff-fa9d-4689-a87f-d6de00cafaca">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=373098007" xl:show="new">R-00317</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_15cb7a5c-be6b-4fb0-a6bb-d1371a084082">Mean Value of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_40310ccb-cb70-4ed6-a64f-32f37fff7ab2">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=373098007" xl:show="new">373098007</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_952cec0e-2326-4145-a99b-95527d283bb6">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1298794" xl:show="new">C1298794</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0a3b96ef-d207-470b-a0fd-75c809a23534">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_179ddd19-5aa0-412d-86be-38fff9c75156">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=373099004" xl:show="new">R-00319</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b755d055-0bb6-4c08-8520-71f7970726db">Median Value of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a6afca5a-7731-419b-8662-e2f917968201">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=373099004" xl:show="new">373099004</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b175991-8b08-4a03-95bb-95c6d7bc6e15">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1298795" xl:show="new">C1298795</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_65d61f36-bf04-49cf-8c21-5197f208a465">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_65baeadc-8ae5-4dbe-908d-d82001c99d41">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371890005" xl:show="new">R-00377</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ee95d772-d36f-4097-aeea-94276e2861da">10th Percentile Value of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ab4338fe-3d0b-45cf-985d-1c6eb821f8eb">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371890005" xl:show="new">371890005</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d675b7b3-d365-40f1-a7d2-c1818bcc88fd">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1299359" xl:show="new">C1299359</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_11f21519-af70-464e-bbce-cd1442b058fe">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7d42a6a2-2bfd-48a9-b5a7-a419c14c3326">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371888009" xl:show="new">R-00397</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d4030199-449b-4d7e-8f3d-a6da8123dee2">5th Percentile Value of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bad7f1ea-5b77-4b75-b29c-d66d6ffcf513">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371888009" xl:show="new">371888009</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fb4f2213-45b7-40b2-b634-3338e2b63984">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1299357" xl:show="new">C1299357</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8058ecb4-b122-4105-adbc-2c7c5a3ccd30">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_533b7b12-d7c1-40b3-8641-c0d20daa342f">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371919006" xl:show="new">R-00347</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fbb2b205-71ba-4889-b2b7-bd8a029ccd5a">1 Sigma Lower Value of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a491be02-0cfa-4169-b33e-bf169c6d6c3a">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371919006" xl:show="new">371919006</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_11a1dffc-9fc7-4007-89ec-3518b76f5669">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1299388" xl:show="new">C1299388</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_52e164fa-92c3-46af-aba3-1da00bfbea1d">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cc8a8345-4097-45e8-a476-092b5bd2c1c0">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371918003" xl:show="new">R-00388</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d4f71498-93ba-46da-81e8-9f93b0d9d46c">2 Sigma Lower Value of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a0a2a620-ffc7-47ea-9c20-59a5f4f5e6c0">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=371918003" xl:show="new">371918003</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1777f36e-897c-4149-9dcb-81e82f6e16d2">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1299387" xl:show="new">C1299387</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bc9c733e-a6b5-4376-8eb5-17b6fccedae1">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c0fa8731-74f1-45bc-8778-512d017beefa">
                        <link linkend="DCM_121414" xrefstyle="select: nopage">121414</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_88f86407-0ae1-4658-bfdc-8d5339ff5ba8">Standard deviation of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6d4d13f5-d942-4755-8983-ccadee92ba2d"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1db6cf59-07f4-4d6b-b568-e796254eddd7"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c91beaf8-8dcc-4af0-b349-9e90a60a7b92">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_04a0b609-80f5-4604-9e0b-f14ecf447b80">
                        <link linkend="DCM_121417" xrefstyle="select: nopage">121417</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8ad6eb04-e4d8-4325-9125-46130ae6994c">2 Sigma deviation of population</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ae937d14-6abc-4c73-9bbf-700cb0eec3a2"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e6663519-7eab-478d-9c87-7a44140484e8"/>
                  </td>
               </tr>
            </tbody>
         </table>
         <note>
            <para xml:id="para_3bf38ed7-67b6-4007-8c52-5368c813f2a1">The SNOMED meaning for R-00317 is "Mean - numeric estimation technique", but in the context of its use here, a more specific meaning has been used.</para>
         </note>
      </section>
      <section label="CID 227" status="3" xml:id="sect_CID_227">
         <title>Sample Statistical Descriptors</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_bab24b28-9fd4-4a7c-b78e-978b4d7dbef9">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_227.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_227.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_227.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.32.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_9aec5f08-e117-4bb6-85a8-e751af478e80">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_72567d17-8f17-4cee-b376-add4a947e2e1">
                     <emphasis role="bold">20030327</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_6e76f2a5-d816-43bb-b897-b38614cb2fc2">
                     <emphasis role="bold">1.2.840.10008.6.1.32</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 227" rules="all" xml:id="table_CID_227">
            <caption>Sample Statistical Descriptors</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_942d3e9d-73e4-480b-bc4f-48010580a73e">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cb6002ef-671b-4608-b411-c41f6fbb095c">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d07fd75a-d00f-49ea-8c9f-e081163433e1">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9aad5c30-a304-48e5-8776-a2ab6f970745">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0aaa29f4-3f25-4e4c-9edc-ee83ef932252">
                        <link linkend="DCM_121415" xrefstyle="select: nopage">121415</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e7d86ac0-4902-4d47-90a6-fd0df4b00f15">Percentile Ranking of measurement</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d76b36ca-aff5-4422-8103-a14169c45361">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f2fce3ff-c16c-4328-95ba-1c3a22678c14">
                        <link linkend="DCM_121416" xrefstyle="select: nopage">121416</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1af368e7-54f4-48d2-9057-375c391b9ff8">Z-Score of measurement</para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 228" status="3" xml:id="sect_CID_228">
         <title>Equation or Table</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_20ffb5bb-445e-47b0-9b08-30eb15fe4c4b">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_228.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_228.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_228.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.33.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_53f3c37c-57a4-4554-8389-c26af45ca23f">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_3dee5728-bb75-45ca-9e0c-9f71c66ca727">
                     <emphasis role="bold">20030327</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_c2772cf2-dd05-4186-8c9a-08b1bf489346">
                     <emphasis role="bold">1.2.840.10008.6.1.33</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 228" rules="all" xml:id="table_CID_228">
            <caption>Equation or Table</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_965696aa-ca8e-4bd2-84d5-afe69806375e">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9991f18c-92e1-4b53-a561-0eef92ee8e3d">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_23d0d00b-86da-4cf3-b431-d960701ae20b">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c3b0b8db-e6c2-41f5-befd-bfb0fca3fbea">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0de3b6bf-ad61-4d6c-8827-dddc16d5922e">
                        <link linkend="DCM_121420" xrefstyle="select: nopage">121420</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fdd5f01b-51fe-44b1-afa0-c48b5e58fe1e">Equation</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_450b1754-75ad-4ce5-99a0-03f4ad9dc7d9">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_05a65307-956c-4c54-b65a-98e369c830fc">
                        <link linkend="DCM_121421" xrefstyle="select: nopage">121421</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_503dcb80-e33d-4868-a48e-755697401d3e">Equation Citation</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_93d7ed7c-3939-4ed5-8ff7-bd8f0e2dfce4">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a944aad8-7d7a-451c-a91a-807d82196ec2">
                        <link linkend="DCM_121424" xrefstyle="select: nopage">121424</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ec9e011e-6ed5-4aca-a06e-54968d826fb6">Table of Values</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_145b75e5-c586-4d7d-889e-895f28922d52">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7d442d5a-512c-4016-922f-5492699a8309">
                        <link linkend="DCM_121422" xrefstyle="select: nopage">121422</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_480d9417-7f53-42ad-823f-2400fcc8ca67">Table of Values Citation</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a668b2a0-fcb1-478f-9b7a-8fa3b57dba08">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8a60cf81-d7ad-4ced-a12e-8f2b1c268b88">
                        <link linkend="DCM_121423" xrefstyle="select: nopage">121423</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_332c795f-d474-4c91-9f30-b726db1879c5">Method Citation</para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>


        
        <section label="CID ccc1" status="3" xml:id="sect_CID_ccc1">
            <title>Quantitative Image Features</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_ccc1.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_ccc1.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_ccc1.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu1.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uuu1</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID ccc1" rules="all" xml:id="table_CID_ccc1">
                <caption>Quantitative Image Features</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para>
                                <emphasis role="bold"><emphasis role="underline"><emphasis role="italic">Include <xref linkend="sect_CID_7468" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para>
                                <emphasis role="bold"><emphasis role="underline"><emphasis role="italic">Include <xref linkend="sect_CID_7469" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para>
                                <emphasis role="bold"><emphasis role="underline"><emphasis role="italic">Include <xref linkend="sect_CID_cc10" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para>
                                <emphasis role="bold"><emphasis role="underline"><emphasis role="italic">Include <xref linkend="sect_CID_cc11" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID cc10" status="3" xml:id="sect_CID_cc10">
            <title>Global Shape Descriptors</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                  <emphasis role="underline">Resources:</emphasis>
               </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_cc10.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_cc10.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_cc10.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uu10.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                  <emphasis role="underline">Type:</emphasis>
               </term>
                    <listitem>
                        <para>
                     <emphasis role="bold"><emphasis role="underline">Extensible</emphasis></emphasis>
                  </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                  <emphasis role="underline">Version:</emphasis>
               </term>
                    <listitem>
                        <para>
                     <emphasis role="bold"><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                  <emphasis role="underline">UID:</emphasis>
               </term>
                    <listitem>
                        <para>
                     <emphasis role="bold"><emphasis role="underline">1.2.840.10008.6.1.uu10</emphasis></emphasis>
                  </para>
                    </listitem>
                </varlistentry>
            </variablelist>
           <para><emphasis role="bold"><emphasis role="underline">These features are categorized in <xref linkend="biblio_IBSI_Features"/> as "Morphology".</emphasis></emphasis></para>
            <table frame="box" label="CID cc10" rules="all" xml:id="table_CID_cc10">
                <caption><emphasis role="bold"><emphasis role="underline">Global Shape Descriptors</emphasis></emphasis></caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                   <tr valign="top">
                      <td align="center" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                      </td>
                      <td align="center" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">1.1.1.0</emphasis></emphasis></para>
                      </td>
                      <td align="left" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">Volume of Mesh</emphasis></emphasis></para>
                      </td>
                   </tr>
                   <tr valign="top">
                      <td align="center" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                      </td>
                      <td align="center" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">1.1.2.0</emphasis></emphasis></para>
                      </td>
                      <td align="left" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">Volume from Voxel Summation</emphasis></emphasis></para>
                      </td>
                   </tr>
                   <tr valign="top">
                      <td align="center" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                      </td>
                      <td align="center" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">1.1.3.0</emphasis></emphasis></para>
                      </td>
                      <td align="left" colspan="1" rowspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">Surface Area of Mesh</emphasis></emphasis></para>
                      </td>
                   </tr>                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.4.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Surface to Volume Ratio</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.5.0 </emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Compactness 1</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.6.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Compactness 2</emphasis></emphasis></para>
                   </td>
                </tr>                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.7.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Spherical Disproportion</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.8.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Sphericity</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.9.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Asphericity</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.10.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Centre of Mass Shift</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.11.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Maximum 3D Diameter of a Mesh</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.12.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Major Axis in 3D Length</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.13.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Minor Axis in 3D Length</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.14.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Least Axis in 3D Length</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.15.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Elongation</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.16.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Flatness</emphasis></emphasis></para>
                   </td>
                </tr>                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.17.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Volume Density in Frame of Reference Axis Aligned Bounding Box</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.18.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Area Density in Frame of Reference Axis Aligned Bounding Box</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.19.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Volume Density in Oriented Minimum Bounding Box</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.20.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Area Density in Oriented Minimum Bounding Box</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.21.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Volume Density in Approximate Enclosing Ellipsoid</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.22.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Area Density in Approximate Enclosing Ellipsoid</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.23.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Volume Density in Minimum Volume Enclosing Ellipsoid</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.24.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Area Density in Minimum Volume Enclosing Ellipsoid</emphasis></emphasis></para>
                   </td>
                </tr>                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.25.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Volume Density in Convex Hull</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.26.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Area Density in Convex Hull</emphasis></emphasis></para>
                   </td>
                </tr>                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.27.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Integrated Intensity</emphasis></emphasis></para>
                   </td>
                </tr>                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.28.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Moran's I Index</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.1.29.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Geary's C Measure</emphasis></emphasis></para>
                   </td>
                </tr>

                </tbody>
            </table>
        </section>
        
        <section label="CID cc11" status="3" xml:id="sect_CID_cc11">
            <title>Local Shape Descriptors</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_cc11.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_cc11.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_cc11.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uu11.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uu11</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID cc11" rules="all" xml:id="table_CID_cc11">
                <caption>Local Shape Descriptors</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">DCM</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                        <link linkend="DCM_ddd051" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">ddd051</emphasis></emphasis></link>
                     </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Roughness Maximum Valley Depth</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr>
                        <td align="center" colspan="1">...</td>
                        <td align="center" colspan="1">...</td>
                        <td align="left" colspan="1">...</td>
                    </tr>
                </tbody>
            </table>
        </section>
      
            <section label="CID 7466" status="3" xml:id="sect_CID_7466">
         <title>PET Region of Interest Measurements</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_6186669d-9c05-43b1-9680-352960141e22">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7466.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7466.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7466.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.999.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_d6bcb7f6-fc91-4694-85cf-a4ffc723f650">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_63dd5162-3822-406b-b1f9-024706187ac2">
                     <emphasis role="bold">20141110</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_917acd5b-bde4-4d90-a71d-172cc65c5e8e">
                     <emphasis role="bold">1.2.840.10008.6.1.999</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7466" rules="all" xml:id="table_CID_7466">
            <caption>PET Region of Interest Measurements</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_73f34227-c828-4003-9b61-801388f3aef3">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3e388532-0138-425e-a900-6ab5d2128f3e">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2357d13d-5bb1-4012-9f80-125d6296a94b">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_37da2b63-b693-4770-ac20-c07faebfe515">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f6c13a6c-dd8a-415e-afe5-f73e2e6b8130">
                        <link linkend="DCM_126032" xrefstyle="select: nopage">126032</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fc25aca3-dc2c-4803-b85d-0b4f76578905">Metabolic Volume</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_29ed1c6f-a86c-45e9-846b-b88b6f49225a">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4ba1e896-82ce-4692-9424-8803de7220e4">
                        <link linkend="DCM_126033" xrefstyle="select: nopage">126033</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c5ab2110-6b0d-480d-b6b7-5a5a16f3314e">Total Lesion Glycolysis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8c70e71b-95b2-41cd-9ba0-1c4e68e3720a">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4ccc09a2-3777-4cec-ac61-e5ea62d37541">
                        <link linkend="DCM_126034" xrefstyle="select: nopage">126034</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b4c3dd11-1bfb-4b81-b4dd-244153fbeec8">Glycolysis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_65287ecd-8096-469e-84e3-3d10c7fba03e">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4d8bb2c5-3854-4c6c-81fd-09ee1d98e0fe">
                        <link linkend="DCM_126035" xrefstyle="select: nopage">126035</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_2525f4f0-d3e9-4f79-934b-d7df6e4d86b9">Total Lesion Proliferation</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4f3cd6d5-4e50-49e9-a5d9-c6eff902ede3">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_26a569a9-c0cf-46d8-86fe-d01faee94946">
                        <link linkend="DCM_126036" xrefstyle="select: nopage">126036</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_dd1de2c1-7c9c-456e-ab47-209c6dd8d591">Proliferative Activity</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_738e9ddc-bb79-4e2b-a08c-0ff01e38e69e">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aa540975-5353-4706-a138-3a363cd99a2c">
                        <link linkend="DCM_126037" xrefstyle="select: nopage">126037</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_433643e1-c35e-4351-b05a-977c0b595c33">Standardized Added Metabolic Activity</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_53f92a84-9a0e-4fa7-a1c1-fd5b629da332">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9bf5a308-099e-43a4-bbaa-653c9d20f47b">
                        <link linkend="DCM_126038" xrefstyle="select: nopage">126038</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b4feca2e-2258-40bf-aa67-4d97fc2ca4ce">Standardized Added Metabolic Activity Background</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cacf7e2a-9745-433a-b0b4-4c4c8d29d8de">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fe64f07e-d0e3-4293-90ea-842f2643b52d">
                        <link linkend="DCM_126039" xrefstyle="select: nopage">126039</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_94027c7a-c35d-4d44-ad6a-83c68238974a">Lesion to Background SUV Ratio</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e27e787b-62b5-462e-9207-70e10a0d37fb">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ef08b9a7-9a00-469a-a0d3-77b568955e4c">
                        <link linkend="DCM_126040" xrefstyle="select: nopage">126040</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7c9f79d8-78f1-490c-be0f-7d2512830db7">Background for Lesion to Background SUV Ratio</para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 7467" status="3" xml:id="sect_CID_7467">
         <title>Gray Level Co-occurrence Matrix Measurements</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_c0982539-8baa-46c5-916b-75dbdc38fa55">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7467.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7467.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7467.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1000.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_d68c18bc-202f-4ee9-8465-18610a4dcc7b">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_04565925-5d06-410e-bb5c-8bb21c20cde8">
                            <emphasis role="bold"><emphasis role="strikethrough">20171122</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_9a040793-712c-4699-8ff2-6acac2c1654a">
                     <emphasis role="bold">1.2.840.10008.6.1.1000</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7467" rules="all" xml:id="table_CID_7467">
            <caption>Gray Level Co-occurrence Matrix Measurements</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c7a6700c-50a8-4203-bc2b-2d071b998436">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e25b50e3-fe79-4f6a-91fb-f1761819ada8">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_eb595bda-d969-4d1f-8506-824e4a812125">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8df55bcd-9484-4a21-899e-fb8e40ef8d9e"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_73e8b11e-8495-4e97-958b-e1903bc25130">
                                <link linkend="DCM_126060" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">126060</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.4.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a5484a73-c304-4355-ba50-30589d57a58a">Joint Entropy of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_812f778f-076c-4bd2-a7f7-b4befeda0937">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5498a921-2fbc-48d4-8e30-020269cf0404">
                        <link linkend="DCM_126061" xrefstyle="select: nopage">126061</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_714a5f55-ae6e-441a-9cbd-93a3c0c862ba">Root Angular Second Moment of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0f42e901-3e6a-47ad-a8f9-b96021fa6de3"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c9b1093a-e899-4cc6-b427-c893ec88b896">
                                <link linkend="DCM_126062" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">126062</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.16.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5279fa7a-a897-4181-af57-cc93376427fc">Inverse Difference Moment of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0b486b02-3edf-400a-9502-41f444adecd9"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bdc87e0d-c5d5-4f7b-87bc-e955479e6af9">
                                <link linkend="DCM_126063" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">126063</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.12.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3e1cdf17-82e2-493d-be54-5ef0e96e39d9">Contrast of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2bc3513c-0623-43df-b121-2f984746da6c"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_10a53350-3324-4b4c-9b78-af9b07d676a7">
                                <link linkend="DCM_126064" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">126064</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.13.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_86c5bfe6-180d-4f02-b982-3678a7fd295c">Dissimilarity of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2ad2f3d0-65b8-47cd-bc91-0c0af91bd977"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6a3cab55-1db2-4a8a-ab6f-1cd5933189b4">
                                <link linkend="DCM_126065" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">126065</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.11.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4566551f-31e3-4fe2-8fc6-00b09b51c6b7">Angular Second Moment of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fe9d87c3-a39f-45e8-b2df-ca69cb4d82ad"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_952957bf-d946-4363-a60a-2670eff0d610">
                                <link linkend="DCM_126066" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">126066</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.19.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_cbb09e54-e125-4afc-90ba-a33a0cb39acf">Correlation of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_33603335-d6b4-465b-bfc6-0c2bbaf3be17"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_06facba2-610a-4334-a007-f00c6da5760b">
                                <link linkend="DCM_128781" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128781</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.1.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0f5dbc38-62db-49db-b6cf-6fa77c25cf5a">Joint Maximum of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_68f94537-26fa-4697-bca8-ecb58a959136"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ed8f07ef-0bda-4612-8d9e-0b606de5f018">
                                <link linkend="DCM_128782" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128782</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.2.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b50a6b81-1f39-4692-8278-3639eb96f3e8">Joint Average of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_80a48b21-2d6d-4da7-a994-442070aed71d"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_799a3705-0f0f-4e65-8062-97a7089299df">
                                <link linkend="DCM_128783" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128783</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.3.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1a64c695-b68b-4ddb-b4f0-922f6590660c">Joint Variance of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6dd1c1fa-c277-4e4b-9953-baedca2919f3"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a5365bc2-7be5-4b4d-a96c-c4bad7f31e98">
                                <link linkend="DCM_128784" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128784</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.5.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4f88f261-8812-4aa5-a7b8-e5e5c393b54d">Difference Average of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ce3d408c-a00b-4415-b1ef-37a154ef40d2"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ab6fd82d-2cc8-440c-8c9a-ab0192610904">
                                <link linkend="DCM_128785" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128785</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.6.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4268bb84-d551-4f09-9546-8adc9ea753e4">Difference Variance of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5b3bd586-8d8e-4167-8702-5292d1fb6590"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6ca71ae4-8fd5-4d43-8827-c7e997b4f9e5">
                                <link linkend="DCM_128786" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128786</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.7.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d35e0c46-c8a0-4a15-ad6c-8581198daf55">Difference Entropy of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8fa0ab95-1c79-4cb5-a84b-ff172984c482"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f118e5ac-0d69-40f4-b368-c041a1c8a6e5">
                                <link linkend="DCM_128787" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128787</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.8.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f399a192-0b05-41ae-b59d-8b92514966ab">Sum Average of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c44d651a-a46e-492b-ba2c-54021026399b"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_088758b0-b30c-434e-a000-0445f89186c4">
                                <link linkend="DCM_128788" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128788</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.9.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1a97ce0e-ac2c-4359-87d7-80d54d2b38b1">Sum Variance of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b9e3bf09-a463-4ddd-8ea9-00f6e07def66"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e4e1911d-6eda-45e9-ba2b-aa75e31fcff7">
                                <link linkend="DCM_128789" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128789</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.10.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6efaf744-3a44-409f-aacd-d1590caf3c15">Sum Entropy of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9b5c58a0-4e17-4db4-8e74-6654fa6d28ba"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1563d293-bb64-4995-87be-4d70b15521ee">
                                <link linkend="DCM_128790" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128790</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.14.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_514824b7-755f-43ec-b711-1027f184a008">Inverse Difference of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_67b6c2fd-f05a-47c2-8eb1-9546813b5aa1"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_829ecece-f80b-4251-a0ce-e7314ca8e069">
                                <link linkend="DCM_128791" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128791</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.15.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c1f10e3b-e522-48fc-99ec-b6d3959602c2"><emphasis role="bold"><emphasis role="underline">Normalized</emphasis></emphasis> Inverse Difference of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4ebfe2b6-62a4-4baf-8749-a67bfd411ade"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ddaee9df-abb6-4c1f-84f0-ea232f830d84">
                                <link linkend="DCM_128792" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128792</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.17.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_783d5162-56c9-4c14-a833-8da7128b196e"><emphasis role="bold"><emphasis role="underline">Normalized</emphasis></emphasis> Inverse Difference Moment <emphasis role="bold"><emphasis role="strikethrough">Normalized</emphasis></emphasis> of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c49d740c-121a-421e-968b-7debfe10b114"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ef887b03-f838-4a7c-aaab-40f7cf162c30">
                                <link linkend="DCM_128793" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128793</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.18.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_acaa723d-d696-4239-b5c6-0a171ce56307">Inverse Variance of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f0e88771-6943-4963-a82c-11683aefe8ff"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3c593075-f1a7-4e2e-bed1-4a86cb829f15">
                                <link linkend="DCM_128794" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128794</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.20.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4d344257-f4ff-43bb-8172-1a817c2bf4d1">Autocorrelation of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5075e8a9-8fa6-4295-b2be-4efeef423da5"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ec42aaa6-309a-44b3-b527-4075e53220e5">
                                <link linkend="DCM_128795" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128795</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.21.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_23597cc6-bd14-4fb9-92c2-e1f3b19107ab">Cluster Tendency of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3c82bb0f-714d-4f62-a255-eebdd854db20"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_69dbd42c-b920-42b6-8519-d405483d9574">
                                <link linkend="DCM_128796" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128796</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.22.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ff10442d-bde3-4b42-b6f1-febd09961138">Cluster Shade of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0e9f0794-1a04-4bfe-9d3c-378527093969"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fa9892b8-0714-467f-91ca-1cd1cec1a48e">
                                <link linkend="DCM_128797" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128797</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.23.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d8e9aef1-e1bc-40cc-8ac6-cf6289a4c33f">Cluster Prominence of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_98b91f04-eb36-4480-a4c4-2d115faceb81"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_acf7438d-5934-4c2a-9916-8ae8f0a75a04">
                                <link linkend="DCM_128798" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128798</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.24.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_519f8754-aec5-4795-ae89-60c6181a638c">First Measure of Information Correlation of GLCM</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ffd69dd-d67e-4adc-b1c7-c812b1169ca5"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8e0d4749-a274-4551-ab3e-d9e881d592b9">
                                <link linkend="DCM_128799" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128799</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.6.25.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1d34447d-8059-4528-a149-f2ed3fea03f6">Second Measure of Information Correlation of GLCM</para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 7468" status="3" xml:id="sect_CID_7468">
         <title>Texture Measurements</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_60d46d47-a714-4fbb-b9e2-7ca0c0fca537">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7468.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7468.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7468.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1001.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_6ecad3a2-9e1a-49ee-9df2-d086eeec7470">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_a11032d7-bdbe-43e9-a8d9-60db8f619884">
                     <emphasis role="bold"><emphasis role="strikethrough">20171122</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_11834e7b-f430-46d4-bb52-c074cfe2d9b1">
                     <emphasis role="bold">1.2.840.10008.6.1.1001</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7468" rules="all" xml:id="table_CID_7468">
            <caption>Texture Measurements</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3019298e-4248-470d-ae84-ce392ee6073b">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b490b4df-bcaf-4d8d-96f8-61ce462c1fee">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d10076be-629d-4793-ad01-1a6b89cf4268">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para>
                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_cc20" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_10627633-7d75-47e0-a3de-4c112e86a100">
                        <emphasis role="italic">Include <xref linkend="sect_CID_7467" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_a7da5261-de2c-4dca-b682-16f3ad8071e0">
                       <emphasis role="italic">Include <xref linkend="sect_CID_7475" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_25ec107b-e322-4780-8632-d0cb9fc86198">
                        <emphasis role="italic">Include <xref linkend="sect_CID_7476" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </emphasis>
                     </para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="left" colspan="3" rowspan="1">
                        <para>
                            <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_cc30" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                            </emphasis>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="3" rowspan="1">
                        <para>
                            <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_cc31" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                            </emphasis>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="3" rowspan="1">
                        <para>
                            <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_cc32" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis>
                            </emphasis>
                        </para>
                    </td>
                </tr>
                <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_319676bd-7c7f-4972-aa10-505bb7bd8302">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5ea594ce-897c-4da7-9641-62ed37d1bf03">
                        <link linkend="DCM_126050" xrefstyle="select: nopage">126050</link>
                     </para>
                  </td>
                  <td align="left" colspan="1">
                     <para xml:id="para_48152c1f-e876-4f03-ad8f-e9ce952adcb9">Fractal Dimension</para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 7469" status="3" xml:id="sect_CID_7469">
         <title>Generic Intensity and Size Measurements</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_ea2a84ce-a848-449d-84af-90cbbda52580">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7469.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7469.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7469.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1003.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_6a75cc1e-2f95-46f0-90c5-21190e6aadd5">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_13f55a11-9c24-4c6d-a016-2b62890b7f2e">
                     <emphasis role="bold">20141110</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f80d1bb6-18fd-4f46-8aae-803475085f16">
                     <emphasis role="bold">1.2.840.10008.6.1.1003</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7469" rules="all" xml:id="table_CID_7469">
            <caption>Generic Intensity and Size Measurements</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_da4f3e26-0e58-41c4-afd2-f5e0c5437d96">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_af75bce2-f7e4-4337-a1c2-49a7bdc2c504">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5bbae1bf-f764-40af-ad33-0fd180a5741d">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_7d5813fe-198b-458c-83fd-61d902ef1a01">
                        <emphasis role="italic">Include <xref linkend="sect_CID_7180" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_7ecdc418-171c-4e3c-89f7-daa2f7e3fade">
                        <emphasis role="italic">Include <xref linkend="sect_CID_7470" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_83fcba24-f472-47b1-babe-50d2ad9d4266">
                        <emphasis role="italic">Include <xref linkend="sect_CID_7471" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_c5867b3e-d47d-4a74-baa6-d9b6a9e33900">
                        <emphasis role="italic">Include <xref linkend="sect_CID_7472" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 7470" status="3" xml:id="sect_CID_7470">
         <title>Linear Measurements</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_97af33c9-cee2-40a6-b1bb-f286e6e6deca">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7470.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7470.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7470.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.524.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_b7c3dce4-6f9c-4192-a0d9-3e3a05302c15">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_9cb45d1f-f56c-429c-83c7-e8491d9e7dd9">
                     <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis>yyyymmdd</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_a6bd7eb7-1fc7-41b3-a6fc-19ad9ec87cbf">
                     <emphasis role="bold">1.2.840.10008.6.1.524</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7470" rules="all" xml:id="table_CID_7470">
            <caption>Linear Measurements</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dd55265f-d337-45d8-a1bf-0f9d8766cd56">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_042aa9c0-514c-46b6-bc94-ec9f6d3bd375">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a3235131-7ac0-45af-94d4-5f294a80fce8">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f2c2f513-5aec-4c8b-9c0f-b88894b2d749">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a1c2d697-3091-4e20-944a-073cd6fda9fd">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e84a5c40-73ad-4959-9b27-6a2f95250a71">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_794e7979-20bb-44ae-b536-ee9d2375365d">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=410668003" xl:show="new">G-D7FE</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a42b3c38-c045-4875-bfe3-c687d1ec17ea">Length</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d54d0cd4-f149-4b0e-802a-4b2ea598ca72">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=410668003" xl:show="new">410668003</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2e397078-1ba2-46e8-afc3-785c3b0ef252">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1444754" xl:show="new">C1444754</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_35a0d118-4c85-4e38-82f1-35b76929f488">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d65d7536-321c-447f-9936-21a57156a853">
                        <link linkend="DCM_121211" xrefstyle="select: nopage">121211</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0b6c63ed-5e06-4c32-82b2-3bc6c63596d0">Path length</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cfd55bbb-efda-4bdb-8fb3-95d8b146fb05"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ffe6bdab-5c32-4ab7-8612-6199713cf0f5"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5555ff59-2a52-4d52-9b13-1294624c1a40">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e74723e3-376d-4bda-93d4-ccbbbedb688b">
                        <link linkend="DCM_121206" xrefstyle="select: nopage">121206</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_bbf59580-5679-4157-b00c-4979785ac591">Distance</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dd405118-8542-467c-9739-1dbcb7d0c815"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4cc4f88e-6b88-4aab-b9e8-214a605ea82c"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_18984073-2fa4-4cd9-8aeb-99cdcd99985b">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d0c881b7-78b5-4efb-a36b-868fa207fa4e">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=103355008" xl:show="new">G-A220</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3e5b8948-6c25-45da-9bd3-5af188a20a2f">Width</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0f84fd04-5c57-4ab3-8216-526c3f12d9a7">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=103355008" xl:show="new">103355008</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_33aa8f48-9b00-4043-94a4-e75bf9b0097a">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0487742" xl:show="new">C0487742</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6d910954-a416-403d-8abd-0aff53213264">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a75473a6-8797-4c44-a0c2-197d384b6859">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131197000" xl:show="new">G-D785</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_905164a2-ceb0-4f81-834f-94fc96482bae">Depth</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b3288ac-6e6d-4a8a-960e-7837b60b7563">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131197000" xl:show="new">131197000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_892078bb-644a-4f61-b6d2-781303ccf8f2">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205125" xl:show="new">C0205125</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_951b7ad6-54f7-489a-a4b2-c8a5a6643d88">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_21e72804-e3d0-45fe-83ae-0e27ee54f79b">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=81827009" xl:show="new">M-02550</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_70c5ddf9-cdae-44d7-8b58-b4f6d1ff261d">Diameter</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_45b6c7e3-5c87-4e3f-8568-6f2612a1532e">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=81827009" xl:show="new">81827009</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c05cca22-4531-493e-9f2c-88a627d3602c">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1301886" xl:show="new">C1301886</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_154becd3-efe3-406c-98da-70858d3ff151">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_673e6aee-8855-456b-ae64-c0f8d3184929">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=103339001" xl:show="new">G-A185</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_946a10d2-0b0b-4919-8d5a-66ac71d03a73">Long Axis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e1f67cd8-29f2-4b3c-a904-a778c4ecaa20">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=103339001" xl:show="new">103339001</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_006a3534-ff27-4284-aba3-1d7026e4d27b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522487" xl:show="new">C0522487</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_de6e7a38-70c6-4554-9d62-b73d37c59617">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_48de58cc-2a27-4f1a-948a-717636a7487e">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=103340004" xl:show="new">G-A186</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_60db2604-71ba-4a3e-8566-cbc41a07ed05">Short Axis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6fad58e0-9ec7-48fc-8e9b-b8c61c451769">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=103340004" xl:show="new">103340004</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fc73f69d-abc9-4446-85dd-849c5e17fc6c">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522488" xl:show="new">C0522488</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_de8c7f24-2d8c-4529-89ba-cf8f63c3f4ae">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2eb90a61-a232-41f0-af0e-c94e56245800">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131187009" xl:show="new">G-A193</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9b37f283-3ff0-4261-a8ef-c226b2452e88">Major Axis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b4d85f50-167c-4d59-ad1c-21033494a3db">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131187009" xl:show="new">131187009</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf0341ab-82ec-42d2-8363-0c6d63ef2603">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295723" xl:show="new">C1295723</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ca2aa0ed-0636-45bc-ae24-79ecba7dc9bb">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f2327e72-3c13-49d2-9fd3-3f68be3efb79">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131188004" xl:show="new">G-A194</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ac49cfcf-19c6-4e77-b1d5-fe50947f3b9a">Minor Axis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2817190f-5fd0-47e0-af66-0e2f2bcf0368">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131188004" xl:show="new">131188004</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f992a3e1-f708-4e25-9284-d80f09b82314">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295724" xl:show="new">C1295724</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf5d6ba3-9762-4ead-9151-10ac0b7ed8f0">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f5739ac2-838f-4b35-8b5b-fe59d9a0fd01">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131189007" xl:show="new">G-A195</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_04a8cc8a-ff45-43c3-a923-51bb139438e8">Perpendicular Axis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ab00b12f-88a0-44bd-8e35-478d28ed5360">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131189007" xl:show="new">131189007</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0f345e8a-b682-4265-b503-eaf2b26169af">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295725" xl:show="new">C1295725</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_12c0d2cb-fdf3-4bb6-a741-5ec1c0ef9ce9">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_964de4e6-8184-4c87-b141-9f6317de78ed">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131190003" xl:show="new">G-A196</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_18293b98-66f9-441a-b181-bcd88969d1ee">Radius</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f983ae55-8c52-4f71-b29c-854bf041c151">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131190003" xl:show="new">131190003</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2cece962-870c-4951-96b1-4ccae5dfb63b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1306504" xl:show="new">C1306504</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e75c1ad3-652f-419a-ab6e-27e6491289a5">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_33e30405-12bf-4699-89c3-ae43853e95b2">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131191004" xl:show="new">G-A197</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_aad4dd37-8d10-4f70-b428-170b763cb6bc">Perimeter</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cad4bb29-db9c-4c5b-9efc-83cedeadd772">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131191004" xl:show="new">131191004</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5e2ea613-19bd-4a99-9511-4dc6648922f8">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295726" xl:show="new">C1295726</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d4ad059d-e6ef-49fc-a331-509811a7c040">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8e50255c-2ba1-49f8-84e5-468aaaa428a4">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=74551000" xl:show="new">M-02560</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_810a0827-cc9a-4173-8cbd-36bfee34e03c">Circumference</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_17d76d1e-0c3e-45e5-bada-166908a27310">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=74551000" xl:show="new">74551000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_be610b92-1d9f-4285-a13e-33ef358843a1">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0332520" xl:show="new">C0332520</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6519ef4d-2f56-4573-8cd7-a6fc0b3c7bd2">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cba2ac1a-763a-45c5-bf21-98f0e7bc5590">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131192006" xl:show="new">G-A198</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_427c3890-3b1e-4da7-a50e-86960680b3a3">Diameter of circumscribed circle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_050a987a-b3c3-49a7-a920-76c7902c8301">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131192006" xl:show="new">131192006</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_80c9896f-db55-4cb0-b0d4-5f08b1b747de">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295727" xl:show="new">C1295727</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9ff42a7f-d809-42d2-8a1a-1b0139b2e260">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8b8028a5-424c-41eb-a802-4c5e838f9eab">
                        <link linkend="DCM_121207" xrefstyle="select: nopage">121207</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9f511551-3ca0-4c4e-bd2e-a7f9c4c8e17f">Height</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a08f7998-26b3-496e-86e4-b85254e38dc8"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_20831e26-e9e3-4101-ad48-53eeeee28eaf"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">1.1.11.0</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Maximum 3D Diameter of a Mesh</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">1.1.12.0</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Major Axis in 3D Length</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">1.1.13.0</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Minor Axis in 3D Length</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">1.1.14.0</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Least Axis in 3D Length</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 7471" status="3" xml:id="sect_CID_7471">
         <title>Area Measurements</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_092f87ef-090b-48de-96fd-675a9d47c834">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7471.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7471.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7471.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.525.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f81a49e9-76db-40d3-8e8f-978af4727a3f">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_6d70f4b8-cb47-4e84-b5f7-27a9163f6045">
                     <emphasis role="bold"><emphasis role="strikethrough">20020904</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_c490e1b4-00ef-44a6-8049-2072ae62206a">
                     <emphasis role="bold">1.2.840.10008.6.1.525</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7471" rules="all" xml:id="table_CID_7471">
            <caption>Area Measurements</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_de2ec96e-cab3-4522-b7f0-e8706ed07a2c">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7b413c98-7a34-4425-9f55-e516b191ccd8">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c72a864d-4711-4640-917d-78e9fb3b76c5">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ff80e0d7-85cc-496b-a754-519ee3b5cf69">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_54988d75-fd72-4ec8-9897-b1f4076a6bc2">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_52ca5ec6-a199-4af2-b194-015f2a6c0484">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_99b5345c-acab-4e2d-b4be-222c8e6cd4ed">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=42798000" xl:show="new">G-A166</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e2da855d-fd93-46fa-93be-27612ff3e768">Area</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_17fc04b4-f011-4898-b9e3-0e76cdb0e0da">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=42798000" xl:show="new">42798000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_72e4e6b5-8935-45d9-ae51-2415d2f962e6">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205146" xl:show="new">C0205146</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5bd995cf-ff2f-4ce2-9f7d-5a4e949f0edd">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dbb9e8db-57e3-40de-b712-6e8a01dcfe4e">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131184002" xl:show="new">G-A16A</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ecc0f80d-e99c-4003-b7c5-05195dd6a37a">Area of defined region</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f4cb75f4-99d5-48e5-861b-3746f4ae4da4">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=131184002" xl:show="new">131184002</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_704a3f1b-057c-43a9-88e0-ec1396730531">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1295720" xl:show="new">C1295720</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">1.1.3.0</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Surface Area of Mesh</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 7472" status="3" xml:id="sect_CID_7472">
         <title>Volume Measurements</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_71cbc481-6ea8-4661-b522-d9379eacb8ff">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7472.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7472.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7472.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.526.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_91c183b2-53fc-4b3e-a43f-2b77ade71204">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_ddbfccd7-bd31-4421-a5ff-8689375f2f58">
                     <emphasis role="bold"><emphasis role="strikethrough">20020904</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_b9b845a7-4836-47b3-84e0-53f2acb7b8ef">
                     <emphasis role="bold">1.2.840.10008.6.1.526</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7472" rules="all" xml:id="table_CID_7472">
            <caption>Volume Measurements</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_408eabad-b363-4061-be31-d3125dbded2c">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_27aa62d5-5a42-4fbe-ba47-4bca4a2360b9">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_44c924bd-dc70-412b-a4a2-55f15bed91c5">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_09757cc6-3c91-445e-a44c-903dfbff7325">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_341b58e9-5075-4c1f-a3d2-1e9a976634bc">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a2b7281d-cb73-49e0-8d60-3038f26e8365">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_877be71a-3221-4ce7-a5aa-559cb4964ebd">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=118565006" xl:show="new">G-D705</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fa839652-21e3-4170-ad9d-cf4854593378">Volume</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_efd510ab-c11d-45e8-b7d3-ff54eb0d9721">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=118565006" xl:show="new">118565006</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3fce2904-26ae-46ca-9d41-2c6493964ba1">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0449468" xl:show="new">C0449468</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c1f79e39-04ce-4227-bc43-47677b93e09f">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c4f656d1-da90-4630-a7fb-5c07fe01bc4c">
                        <link linkend="DCM_121216" xrefstyle="select: nopage">121216</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1e06f5f1-bb84-4f1c-90e8-706a7ee0c38e">Volume estimated from single 2D region</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_64033129-be9b-4504-af01-5c09bdec7934"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f3d2dd6e-f136-46cd-9ac8-6ba4758ab972"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7824001d-a29e-444e-8718-319d3fe3a7ac">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c7b5d80b-86b7-4a25-af11-9451378c44a7">
                        <link linkend="DCM_121218" xrefstyle="select: nopage">121218</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d198d33c-0c9c-4979-84db-bd240ee5186f">Volume estimated from two non-coplanar 2D regions</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_23b98cdf-33f3-45d9-8e4a-ad0ebeedd667"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ea886e7e-766f-4535-ac78-f78972afe378"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c202160b-be77-4ffb-b613-db399f7cfac3">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ddac8816-c29a-4490-a233-d894ea7112fc">
                        <link linkend="DCM_121217" xrefstyle="select: nopage">121217</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3dc88f33-2ee7-4205-9957-e8d2bf66a79f">Volume estimated from three or more non-coplanar 2D regions</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fc498358-3b58-4b4e-a59a-924ad05933d2"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9e7006a0-350a-47f9-9a03-439c148aeffb"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_75fd1cba-e793-496d-8027-f8a6e7195a7e">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4c8368dc-3997-4ef0-94f3-e08cfbe62585">
                        <link linkend="DCM_121222" xrefstyle="select: nopage">121222</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c2dbe0cf-bfb2-4aa1-b451-6d4f5801c3a4">Volume of sphere</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_81385ddc-664d-46cd-ad90-fde78f232220"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fd5f06df-43a2-422e-8d51-b901cf39c447"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3527da2a-bd4d-4ad2-b366-f9de756bedd4">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e02eb131-1daf-4299-acc0-685219ea2c35">
                        <link linkend="DCM_121221" xrefstyle="select: nopage">121221</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_bcaebc19-238d-48f3-97e3-c7579b6bf536">Volume of ellipsoid</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_220593f6-98c9-40b3-848b-555f93b0f980"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d9f91c7c-a4b8-4994-83d0-f085659d87ed"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3330aee5-f820-4677-b778-0e3c3ded1e0d">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5fe35543-7746-4207-9506-f4a9722031c0">
                        <link linkend="DCM_121220" xrefstyle="select: nopage">121220</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a321a1e9-a0a8-47ae-a8bf-6b48a6e5b7d7">Volume of circumscribed sphere</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_88c8cd25-bca4-4da3-bd24-c5f08c3e305c"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d86b13ab-d1ce-412d-8589-8076bdbf4ac1"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d66b987f-618c-47be-b111-d6cc1bd091b3">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7a2248ed-2959-4e8b-b285-50938a49919d">
                        <link linkend="DCM_121219" xrefstyle="select: nopage">121219</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a589695b-8cb8-484f-8f7b-b88d04557550">Volume of bounding three dimensional region</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4e73b1f5-bf15-448a-8247-4258ab1e94e2"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ef029819-aca9-4b19-8785-5fdce04f9e36"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">1.1.1.0</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Volume of Mesh</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">1.1.2.0</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Volume from Voxel Summation</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
       
       <section label="CID cc20" status="3" xml:id="sect_CID_cc20">
          <title>Intensity Histogram Features</title>
          <variablelist spacing="compact">
             <varlistentry>
                <term>
                   <emphasis role="bold">Resources:</emphasis>
                </term>
                <listitem>
                   <para>
                      <emphasis role="bold">
                         <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_cc20.html" xl:show="new">HTML</link>
                         | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_cc20.json" xl:show="new">FHIR JSON</link>
                         | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_cc20.xml" xl:show="new">FHIR XML</link>
                         | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uu20.xml" xl:show="new">IHE SVS XML</link>
                      </emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">Type:</emphasis>
                </term>
                <listitem>
                   <para>
                      <emphasis role="bold">Extensible</emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">Version:</emphasis>
                </term>
                <listitem>
                   <para>
                      <emphasis role="bold">yyyymmdd</emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">UID:</emphasis>
                </term>
                <listitem>
                   <para>
                      <emphasis role="bold">1.2.840.10008.6.1.uu20</emphasis>
                   </para>
                </listitem>
             </varlistentry>
          </variablelist>
          <table frame="box" label="CID cc20" rules="all" xml:id="table_CID_cc20">
             <caption>Intensity Histogram Features</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para>
                         <emphasis role="bold">Coding Scheme Designator</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para>
                         <emphasis role="bold">Code Value</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para>
                         <emphasis role="bold">Code Meaning</emphasis>
                      </para>
                   </th>
                </tr>
             </thead>
             <tbody>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.1.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Mean</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.2.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Variance</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.3.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Skewness</emphasis></emphasis></para>
                   </td>
                </tr>                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.4.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Excess Kurtosis</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.5.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Median</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.6.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Minimum</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.7.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram 10th Percentile</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.8.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram 90th Percentile</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.9.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Maximum</emphasis></emphasis></para>
                   </td>
                </tr>                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.10.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Mode</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.11.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Interquartile Range</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.12.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Range</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.13.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Mean Absolute Deviation</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.14.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Robust Mean Absolute Deviation</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.15.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Median Absolute Deviation</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.16.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Coefficient of Variation</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.17.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Quartile Coefficient of Dispersion</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.18.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Entropy</emphasis></emphasis></para>
                   </td>
                </tr>                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.19.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Uniformity</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.20.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Maximum Gradient</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.21.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Maximum Gradient Gray Level</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.22.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Minimum Gradient</emphasis></emphasis></para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1.4.22.0</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Intensity Histogram Minimum Gradient Gray Level</emphasis></emphasis></para>
                   </td>
                </tr>




             </tbody>
          </table>
       </section>
      
      
      <section label="CID 7475" status="3" xml:id="sect_CID_7475">
         <title>Gray Level Run Length Based Features</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_8eb22716-0fb6-44da-a52e-3a1d4d42e89f">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7475.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7475.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7475.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1199.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_bc45c28f-12c1-45e4-81b0-42122974d309">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_e0193f86-dcce-48ca-a464-a0f298649301">
                            <emphasis role="bold"><emphasis role="strikethrough">20171122</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_271b21b5-8b6d-4e27-ba19-e7e05b0c1ed5">
                     <emphasis role="bold">1.2.840.10008.6.1.1199.xml</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7475" rules="all" xml:id="table_CID_7475">
            <caption>Gray Level Run Length Based Features</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fd1ec99b-7d30-485f-8202-a1e56bcc6824">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_78b177a9-70ef-4ad2-817f-39a198d136c4">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cbc7dda1-69e7-411b-88c1-7f2619f2e4e6">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a9594c72-a1b1-48c3-8fd1-d4041e094be3"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_50786fe7-c834-415b-bbd3-0c9d1294e507">
                                <link linkend="DCM_128801" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128801</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.1.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7b4727a6-beed-4903-9edb-56b9381ece67">Short Runs Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d4a80b40-9784-42e8-b9be-aef8dadb4c3e"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1ef5d4a8-dafa-4620-ace6-7b986c3c8360">
                                <link linkend="DCM_128802" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128802</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.2.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f373b0c6-605f-4f30-97f3-ff66e008d769">Long Runs Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8d41767a-2a14-4384-931b-aa5c5d0452ef"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_208159c8-2ceb-4f09-8312-2375ab84eaa5">
                                <link linkend="DCM_128803" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128803</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.3.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0004a15e-f5c3-449e-b7a1-30b33650271a">Low Gray Level Run Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7010831c-555e-4259-aac5-65bdbb80bf6f"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8bdb1ccd-fbca-4436-8649-d0c1434a4d02">
                                <link linkend="DCM_128804" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128804</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.4.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_67145ba3-4107-41d0-bb73-7e5153267799">High Gray Level Run Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2092ea33-f1af-45ef-a913-130770965702"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b01e83d9-0816-40c3-aa35-6247a1153114">
                                <link linkend="DCM_128805" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128805</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.5.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1ba205e7-2160-424d-8f79-a946b050565e">Short Run Low Gray Level Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f89f5496-57f9-4bde-a94f-e19a77cbadee"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_366a5d89-0589-4fb7-bb09-489ff6009a8d">
                                <link linkend="DCM_128806" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128806</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.6.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4f8093e4-70f3-4861-9ad2-5ddd33fb89f7">Short Run High Gray Level Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0b73ce74-a912-4385-80bb-3ca8d526c64b"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f7ae5d2e-4eed-4a2c-b86d-7f7c2a8aa657">
                                <link linkend="DCM_128807" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128807</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.7.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a0e7ddca-26a9-47f3-9dd2-628adcebbcbf">Long Run Low Gray Level Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_34412e0d-ec81-469e-84b2-268f3227d5d2"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_27b48038-e128-431b-a33a-ac7e80458d2c">
                                <link linkend="DCM_128808" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128808</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.8.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c624bad6-4459-47b2-9226-0ca888892093">Long Run High Gray Level Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a8048b94-7e89-4a12-81c3-d8954823a2a5"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e614b74f-086f-4276-afe4-2968d9689c12">
                                <link linkend="DCM_128809" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128809</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.9.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a6bee9c6-4b64-4113-9894-41889e9d5ee2">Gray Level Nonuniformity in Runs</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c93e27c2-ce13-4f1c-a55b-37f5a729ce8e"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6d608977-2252-48d2-b817-09b609b5063c">
                                <link linkend="DCM_128810" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128810</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.10.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_04fd03b8-e9af-45fd-9b3f-29c25d50bf3c"><emphasis role="bold"><emphasis role="underline">Normalized </emphasis></emphasis>Gray Level Nonuniformity in Runs<emphasis role="bold"><emphasis role="strikethrough"> Normalized</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1db1257f-d50f-45f8-85e5-d4045639d3c0"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_71b9c2e5-4e0d-4784-995a-8845749e6fbe">
                                <link linkend="DCM_128811" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128811</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.11.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b2eb044d-179f-4520-8f2c-ea189512d14c">Run Length Nonuniformity</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_301df1ea-30ce-4145-b2bf-790dad177e88"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d4959465-03c7-47e9-ae4f-74e9418ea3d2">
                                <link linkend="DCM_128812" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128812</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.12.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0f5c61c6-0057-48ca-8b28-e9e628586c42"><emphasis role="bold"><emphasis role="underline">Normalized </emphasis></emphasis>Run Length Nonuniformity<emphasis role="bold"><emphasis role="strikethrough"> Normalized</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_44eaf4fb-fd70-40eb-915f-13f5be48ae9d"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_baf040e7-4155-4ecf-aa49-1e9d899dcf76">
                                <link linkend="DCM_128813" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128813</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.13.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d4490902-85c7-49f7-acaa-6c97bf1fa7bd">Run Percentage</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1c7fde75-9ad2-4a4e-a743-57548fbd9335"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ea41510-c2db-43ab-9482-3bd8dff57da3">
                                <link linkend="DCM_128814" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128814</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.14.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_995c77dd-3542-42cc-ae98-3ba5213ef9c7">Gray Level Variance in Runs</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5ddc2564-5cd1-4732-87c0-b7c0bbeaa8e7"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e8f603ca-5c43-4238-a60a-8b54be1bd961">
                                <link linkend="DCM_128815" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128815</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.15.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_18e74fa5-3fff-4738-b173-6d3bdd7c6e10">Run Length Variance</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d6f27395-30da-414f-aaaf-c680d83ae7e3"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5e2b3d8b-dfd4-4061-bf99-19bd41a66309">
                                <link linkend="DCM_128816" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128816</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.7.16.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6369b7ed-ebb9-45d2-8c40-659b7bcd50f4">Run Entropy</para>
                  </td>
               </tr>


            </tbody>
         </table>
      </section>
      <section label="CID 7476" status="3" xml:id="sect_CID_7476">
         <title>Gray Level Size Zone Based Features</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_d885f202-99b3-46f8-b275-3a92f77a0610">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7476.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7476.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7476.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1200.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_a9f2d7a8-9ca2-480e-9579-3935ece81531">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f45aaa19-4ab4-41c5-bb33-b30d9f7a6f2c">
                            <emphasis role="bold"><emphasis role="strikethrough">20171122</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_adad8731-22d5-4ce9-864a-f92c4fa736d8">
                     <emphasis role="bold">1.2.840.10008.6.1.1200.xml</emphasis>
                  </para>
               </listitem>
            </varlistentry>         </variablelist>
         <table frame="box" label="CID 7476" rules="all" xml:id="table_CID_7476">
            <caption>Gray Level Size Zone Based Features</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6529dc47-dbe4-4a60-8d2b-cdf1fd05d8ab">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_beac433d-0133-4be9-b8cb-7ae2c309816a">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1d4e8ed5-ae44-4632-91bd-2d167f88e3e0">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_deeb3e3a-fe71-48d6-b1be-697bee105142"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9b9182e7-e2a1-401d-bdcf-421139a79da3">
                                <link linkend="DCM_128821" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128821</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.1.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ffd3a781-636c-4036-b606-9cd98776657d">Small Zone Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0250085e-f702-4f68-869b-4d393052fa39"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0cf911e8-7aac-4911-a054-e6a1163fdf54">
                                <link linkend="DCM_128822" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128822</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.2.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0b71a920-14e8-4102-a633-f06a33e2aba5">Large Zone Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_93df66d2-8efe-4f5e-8307-e1723577c964"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_89690ec8-3666-461b-bc64-948703c9df34">
                                <link linkend="DCM_128823" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128823</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.3.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c97b9400-c87b-4ab9-8089-52f9c72787e6">Low Gray Level Zone Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8adf779a-77cc-42a5-9c5e-9f45a3f3d231"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f9fe50ea-af72-4716-8933-121a6d66951f">
                                <link linkend="DCM_128824" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128824</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.4.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7b55e628-f6e8-4743-876a-c748a20ea10e">High Gray Level Zone Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0dcc582d-d36d-4e9a-9a3f-3b3b9cbf6dce"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dbfaecbb-a0f9-408c-9539-12556e0c7885">
                                <link linkend="DCM_128825" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128825</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.5.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d65e7c8c-a8a1-48c1-a7f9-1c4060581b8f">Small Zone Low Gray Level Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0e9fb12a-1bbd-4496-a88a-b60de2074359"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5065602f-695a-4fb0-a859-29ebdde4c6cd">
                                <link linkend="DCM_128826" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128826</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.6.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f38c8e6a-1ce6-498d-ba42-feddf9d65039">Small Zone High Gray Level Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_70a7e365-42ff-4432-9fc2-5e94e0f5ef9f"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_938cd85b-865a-4e97-9a17-7597cf7de3ac">
                                <link linkend="DCM_128827" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128827</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.7.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_379d9477-0efa-4d1f-aad0-e117766f56a8">Large Zone Low Gray Level Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cf92faea-b6ec-410f-ba3f-bb4132474e28"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4a1cef96-0a32-465b-8a19-ab6e3aa05fea">
                                <link linkend="DCM_128828" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128828</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.8.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7dc27542-18fe-46bd-9577-8b834a0ee72c">Large Zone High Gray Level Emphasis</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ee469d70-9ec4-41e1-a720-2848f30209cf"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_69e55298-a61c-449c-9fa5-b50b65a70323">
                                <link linkend="DCM_128829" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128829</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.9.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fde5101e-f132-4b4e-ae33-d51c13b18989">Gray Level Nonuniformity of <emphasis role="bold"><emphasis role="underline">Size </emphasis></emphasis>Zone Counts</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_391ffe43-eec2-44b2-b3b3-e4f81ffda32f"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bb62672e-4270-4229-b7e5-6daaacd88516">
                                <link linkend="DCM_128830" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128830</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.10.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_335b51f2-33a4-46c2-aee7-dd9c44d4bc0f"><emphasis role="bold"><emphasis role="underline">Normalized </emphasis></emphasis>Gray Level Nonuniformity of <emphasis role="bold"><emphasis role="underline">Size </emphasis></emphasis>Zone Counts<emphasis role="bold"><emphasis role="strikethrough"> Normalized</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2d953369-a4a9-46c5-8e5e-8a910f42322f"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c42359d4-a56f-4978-85bf-61a62ef54c69">
                                <link linkend="DCM_128831" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128831</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.11.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0497b5ea-d5ec-407b-ada1-17d3d6dd595e">Zone Size Nonuniformity</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7f0c16ab-726d-4033-b7fd-9b22600b659b"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_22f3dfe7-4de9-4541-9438-175425e06930">
                                <link linkend="DCM_128832" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128832</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.12.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a31a598a-adec-4a7a-988b-0ce90288bea5"><emphasis role="bold"><emphasis role="underline">Normalized </emphasis></emphasis>Zone Size Nonuniformity<emphasis role="bold"><emphasis role="strikethrough"> Normalized</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5850849c-dc76-421b-b400-b8d31f3cee9b"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3bfead76-3f25-4318-a836-0cf0dd40b826">
                                <link linkend="DCM_128833" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128833</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.13.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1ed3c9a3-75c6-46b3-8974-bea9f7d118ee"><emphasis role="bold"><emphasis role="underline">Size </emphasis></emphasis>Zone Percentage</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_31d88fa2-41f1-4c80-863e-81a23b2319ae"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8cb2f4d4-37fa-4524-a2da-ab0e98c5cd5f">
                                <link linkend="DCM_128834" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128834</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.14.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ef1e9ad7-df20-4af5-8880-2a4ab4d3ae60">Gray Level Variance in <emphasis role="bold"><emphasis role="underline">Size </emphasis></emphasis>Zones</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d8704988-c613-4ace-af34-1d0f32efae9a"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1d26257f-d459-4829-aa04-ff706ea82f43">
                                <link linkend="DCM_128835" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128835</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.15.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8d55799a-0f33-452c-86c4-ad911e33bfd2">Zone Size Variance</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_47fedbca-91d9-41b0-a13b-8b2dce2e8eb9"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">IBSI</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_507c5090-fd76-4564-872d-f75f52059fed">
                                <link linkend="DCM_128836" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">128836</emphasis></emphasis></link><emphasis role="bold"><emphasis role="underline">1.8.16.0</emphasis></emphasis>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a71a2853-4a72-4907-8dfe-154882a7940a">Zone Size Entropy</para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
        
        <section label="CID cc30" status="3" xml:id="sect_CID_cc30">
            <title>Grey Level Distance Zone Based Features</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_cc30.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_cc30.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_cc30.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uu30.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uu30</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID cc30" rules="all" xml:id="table_CID_cc30">
                <caption>Grey Level Distance Zone Based Features</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.1.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Small Distance Emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.2.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Large Distance Emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.3.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Low Grey Level Zone Emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.4.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">High Grey Level Zone Emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.5.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Small Distance Low Grey Level Emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.6.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Small Distance High Grey Level Emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.7.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Large Distance Low Grey Level Emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.8.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Large Distance High Grey Level Emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.9.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Grey Level Non-uniformity of Distance Zone Counts</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.10.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Normalized Grey Level Non-uniformity of Distance Zone Counts</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.11.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Zone Distance Non-uniformity</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.12.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Zone Distance Non-uniformity Normalized</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.13.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Distance Zone Percentage</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.14.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Grey Level Variance in Distance Zones</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.15.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Zone Distance Variance</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.9.16.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Zone Distance Entropy</emphasis></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID cc31" status="3" xml:id="sect_CID_cc31">
            <title>Neighbourhood Grey Tone Difference Based Features</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_cc31.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_cc31.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_cc31.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uu31.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uu31</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID cc31" rules="all" xml:id="table_CID_cc31">
                <caption>Neighbourhood Grey Tone Difference Based Features</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.10.1.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Coarseness of NGTDM</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.10.2.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Contrast of NGTDM</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.10.3.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Busyness of NGTDM</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.10.4.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Complexity of NGTDM</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.10.5.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Strength of NGTDM</emphasis></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID cc32" status="3" xml:id="sect_CID_cc32">
            <title>Neighbouring Grey Level Dependence Based Features</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_cc32.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_cc32.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_cc32.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uu32.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uu32</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID cc32" rules="all" xml:id="table_CID_cc32">
                <caption>Neighbouring Grey Level Dependence Based Features</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.1.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Low dependence emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.2.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">High dependence emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.3.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Low grey level count emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.4.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">High grey level count emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.5.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Low dependence low grey level emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.6.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Low dependence high grey level emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.7.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">High dependence low grey level emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.8.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">High dependence high grey level emphasis</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.9.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Grey level non-uniformity of NGLDM</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.10.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Normalized grey level non-uniformity of NGLDM</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.11.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Dependence count non-uniformity</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.12.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Dependence count non-uniformity normalized</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.13.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Dependence count percentage</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.14.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Grey level variance of NGLDM</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.15.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Dependence count variance</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.16.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Dependence count entropy</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">IBSI</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.11.17.0</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Dependence count energy</emphasis></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

            <section label="CID 7180" status="3" xml:id="sect_CID_7180">
         <title>Abstract Multi-dimensional Image Model Component Semantics</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_e4a4c499-6392-4e87-893a-c58c16a08dd5">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7180.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7180.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7180.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.917.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_ff3b7038-d405-4c7f-ae17-7191d2826e30">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_28f1b78a-d2a9-4dc6-aa5e-6bfbdcff75c0">
                     <emphasis role="bold">20170914</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f720fd68-e2cb-4c6d-9543-ba3d793d0a95">
                     <emphasis role="bold">1.2.840.10008.6.1.917</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7180" rules="all" xml:id="table_CID_7180">
            <caption>Abstract Multi-dimensional Image Model Component Semantics</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4b247af2-5bb8-40db-bf6a-245484a7b935">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b80f4034-fc06-4968-a2f5-398b9c1092ea">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e2ab53fe-2ec5-4a52-9f1d-6210705ba140">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3173bac2-2be8-4570-800e-4fa457c87bc6">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bd60520b-71da-44dd-8523-b20b0b01cc27">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_90855da7-4b9e-4075-8b20-478cd2fc5529">
                        <emphasis role="italic">Include <xref linkend="sect_CID_4033" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3c6d5663-5028-454b-874a-93e02df4c437"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2bd18b19-0efc-4888-b12e-e21836704534"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3c5a2a58-501e-451a-bd09-035ead7b0abd">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_034f7adc-9723-4779-9199-aa5139c36aa5">
                        <link linkend="DCM_113063" xrefstyle="select: nopage">113063</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d9b6370a-64e9-4869-93f6-93fef94a52cd">T1</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9516a1c2-346c-4476-889d-82fc5ce7ced2"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_28a48501-9cb2-4d23-a8ec-f16cb160260c"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f85cb0ec-c148-4d0c-863c-ad75b3cb56e5">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_67942caf-7db0-424f-bf71-aff4165f7d50">
                        <link linkend="DCM_113065" xrefstyle="select: nopage">113065</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_037bcdbe-6b81-4b58-9430-998db5014857">T2</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aa645661-a075-4aed-b3db-4f36224a8cb6"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cbd3d1eb-8322-4ea3-8670-fe86bfbede26"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_725bc39e-cdfa-472a-b90b-fa806aa2e689">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_94459002-e24d-4d6f-a126-5cb38d3c5c7c">
                        <link linkend="DCM_113064" xrefstyle="select: nopage">113064</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7fca5e41-e9a3-46e9-85c4-7b019c6d3c4b">T2*</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8c02861e-602f-4303-9b52-3873ef05f25d"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8a1c0c00-4666-4358-a7fc-0dc2ff6d4c0b"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1512dfc9-65cc-46fe-a9ff-614e76ba65d7">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e3f7847d-3404-4963-a2ee-972f031497f1">
                        <link linkend="DCM_113058" xrefstyle="select: nopage">113058</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7d9756a1-00b2-499e-9d3f-85e17d95adc3">Proton Density</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_79e96107-1ccf-4c48-bea7-5ffc2d65b4fb"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ea2cc4fc-6900-4ae7-b650-b036a172c865"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cd778071-df09-40ec-8803-d1ce04538fa9">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c30f1994-c5db-4614-92f6-6ac2d1720320">
                        <link linkend="DCM_110800" xrefstyle="select: nopage">110800</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_140f0743-5b99-47a9-8371-840bda44d1fb">Spin Tagging Perfusion MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f54a643e-d5f6-428a-9565-4b27c99a455f"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6c8b63e8-1a22-4f37-a914-5f2461d3e711"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_14d3604e-75cb-4a77-8ec5-6e4344fc0ad2">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_18189e80-4a6b-4fad-badc-223309090243">
                        <link linkend="DCM_113070" xrefstyle="select: nopage">113070</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a94a97d3-09f5-4249-a913-9f28d43fde04">Velocity encoded</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ca610e75-3ac6-4394-9316-ab5527ce3e07"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0e57e2a4-b990-425d-9726-5420d631c684"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aed2e58f-4695-4839-93dd-a804fb646fef">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b0cf1390-d2f7-4c7c-b7ad-000b5debd5d3">
                        <link linkend="DCM_113067" xrefstyle="select: nopage">113067</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c3587ea4-9942-466a-9172-4612a21dd8e8">Temperature encoded</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_01f97de9-5e42-45bc-865f-01aee6c900c0"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1bdfc6be-7a18-4e3f-9214-f418b8a21492"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0958350f-5c37-4354-8994-a8eb90eba654">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ebc9305b-49ef-4fa5-8ed0-d0f316239466">
                        <link linkend="DCM_110801" xrefstyle="select: nopage">110801</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e5e4b0cb-5ea7-40b6-a3a5-c35f73db4ea7">Contrast Agent Angio MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_72472ebe-a192-4cc2-a43d-6b9140b7e306"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_303564dc-64d3-45e6-988e-7bf08c8f5ad6"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6686f2cd-5e42-4005-a284-31f7901556fe">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_332b9e7d-7a7a-4f72-aeb8-e638dd9da838">
                        <link linkend="DCM_110802" xrefstyle="select: nopage">110802</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_40500b60-93ef-4e4f-b032-4f68d88f7987">Time Of Flight Angio MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_21b52a0b-252e-42d0-99b6-a775c6ab11e8"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_16ff966e-0ea4-4af3-9193-a7a13f07e72e"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_655ab939-09d3-4d46-b011-e6127b361958">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d6ac9eaf-5e74-4430-98f2-795e7bb37747">
                        <link linkend="DCM_110803" xrefstyle="select: nopage">110803</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6d0587d4-cb7c-4f2e-9df4-901e14451be9">Proton Density Weighted MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f3c00cec-6c74-4840-a460-d2eeafadf8e1"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_242ce2fb-5795-420f-875e-430889a3e404"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1d34b6d9-b103-4834-86ee-5bbe7709af61">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6f247160-cb96-465c-aef8-ef0c8ece608f">
                        <link linkend="DCM_110804" xrefstyle="select: nopage">110804</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ce4abcc8-21c2-4c7f-90f5-c090a34ae83a">T1 Weighted MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e234adfd-ce73-4060-96ba-b3d4be0c4682"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3c25fb5a-a6ab-4179-b864-740d6624d1ce"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_06f20b16-04a5-41ba-b6c7-38989939da5f">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a78e63c3-23dc-4011-ae9d-2dcd581183ec">
                        <link linkend="DCM_110805" xrefstyle="select: nopage">110805</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_09e16e97-a9b2-469d-847b-6c40baf69cb1">T2 Weighted MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_708c511a-08e4-4263-aa9c-96fe3e666058"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5fb3b664-916d-4165-bd4c-e9b25e1edc9e"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c1b3ee5a-7071-4ed7-8eaa-0d3119ffce9a">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_69486917-84a6-41ee-8954-a465cb96719a">
                        <link linkend="DCM_110806" xrefstyle="select: nopage">110806</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_32053a1e-4e82-430e-b31c-ad1018aec654">T2* Weighted MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_314a409b-c30b-4e1e-9ca5-fdb0f976923c"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_048c5c19-e25e-481b-bf53-030bda60fdeb"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_03124016-8eb5-46ae-947e-72d669a08a1f">Include <xref linkend="sect_CID_7270" xrefstyle="select: label quotedtitle"/>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0a7e00c4-96c8-49a6-a75b-275d3fefbba8"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ca4dc860-712c-4c44-a570-9130a4986e67"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_54c4a68c-60c0-4e5b-9dba-b1105b8bd5a8">Include <xref linkend="sect_CID_7271" xrefstyle="select: label quotedtitle"/>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e16655ad-229b-49bd-b5e1-fd69ad43a145"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_81331845-fdf7-4cf3-a1b0-7a012561810c"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_b8a3b8ad-c0cd-4da2-97cf-74b13dc8970a">Include <xref linkend="sect_CID_7272" xrefstyle="select: label quotedtitle"/>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5a210513-10ba-4d49-90eb-562b8d5fd629"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7145d1da-d4b3-4d99-ac41-a5739d253647"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_62a95b20-6b46-4325-b3dc-05842decf2b6">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_39a80faf-fec6-4f79-a888-e2b32165660a">
                        <link linkend="DCM_110807" xrefstyle="select: nopage">110807</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8c8b02a7-daff-4989-9bf7-64c2741273e6">Field Map MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9ad6be1d-b4ca-4146-834f-7206bf95cf89"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_86bccd50-9151-4885-8137-063b2174ff38"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_68754716-ae7b-4888-96ae-3d09d74f0410">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4af321d1-117f-4e2e-9abc-258ac02afd50">
                        <link linkend="DCM_110816" xrefstyle="select: nopage">110816</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_129ba9a3-d4fd-4d09-89f6-7ff28f2df728">T1 Weighted Dynamic Contrast Enhanced MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f5414adb-e0d4-4719-ad2a-fd4aa528a028"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2f6ad2e0-b9d0-46c2-9de7-7b622b7e72bb"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fb1955ea-87a8-48e3-b9ea-4ea182f33a41">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_84da54bd-0744-480d-9634-4e8606027347">
                        <link linkend="DCM_110817" xrefstyle="select: nopage">110817</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_aa7746bf-901b-44ed-87be-9f327414d78f">T2 Weighted Dynamic Contrast Enhanced MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cf08fff5-15be-429a-be48-899ff861a392"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1f21b3df-b9ac-4623-afe7-778cf7994ea3"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c093068b-20cd-41bf-889d-38882fac7c60">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7e98beb3-7c25-449c-bf0a-10c6e88874e7">
                        <link linkend="DCM_110818" xrefstyle="select: nopage">110818</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_146b81fb-a794-4ad0-a612-b3d9acb134d9">T2* Weighted Dynamic Contrast Enhanced MR Signal Intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6a77f1c6-b19a-4dc8-8091-e2eff48bec5e"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a97933df-8046-4a8e-a435-cf980077b991"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b51414d-bad4-485e-b2be-290273b19d15">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c5f98da2-e5ba-4178-8a2e-397c59436df5">
                        <link linkend="DCM_110819" xrefstyle="select: nopage">110819</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_754b08c3-892c-4c10-9aa5-bc70729f2959">Blood Oxygenation Level</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d836ce5b-f90c-4414-80c1-c3d7db0f8d61"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c96a824b-3819-4bf1-b94c-b8e984028a0f"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_322894c9-b4c4-4871-ba33-1658204380b7">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_95534f37-65e3-4697-8719-de4d8775a602">
                        <link linkend="DCM_110820" xrefstyle="select: nopage">110820</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_05155093-7c46-436c-bbee-705546f8653b">Nuclear Medicine Projection Activity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_624fb6e0-4514-4b62-9d2c-bb49fec3cee3"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_52f6e8b8-f887-4d87-89ed-777ac3f97c92"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b9e1e3d-b35f-4793-b293-d04c26800201">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c88017fe-0fca-4656-adb5-132bfdad4ab4">
                        <link linkend="DCM_110821" xrefstyle="select: nopage">110821</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_72f1efb9-2220-4642-a5b0-2f888be3c030">Nuclear Medicine Tomographic Activity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b62134d2-93e9-416b-8622-87324c153825"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cb6ade20-065a-4ee8-81aa-06e5169068c7"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dadc4591-f370-4cb4-8f0f-96ef695eae3d">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c35bffe7-5b61-407f-8014-30770d95caaf">
                        <link linkend="DCM_110822" xrefstyle="select: nopage">110822</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_684ffd6c-9b5b-4ef7-b31c-b3efd1029afc">Spatial Displacement X Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8e41db06-d375-43e6-926d-388231819d9f"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0b79e124-5236-4817-8358-48dedcac4afb"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3a4f5dc6-cb1c-42ed-8462-8b2719a33970">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_39be4ef7-6f70-4950-8677-67c241b8ea2e">
                        <link linkend="DCM_110823" xrefstyle="select: nopage">110823</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_31863a1f-152b-4609-aa8b-c45e9bc41f81">Spatial Displacement Y Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ffb68ec7-5431-45a4-a6ce-2bf72a7b13c0"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e943bbc9-f48c-4f94-bc9c-03478e0918e1"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d1160833-1b38-4322-9dd0-8070e52fb0e4">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0de5a1b6-6b69-41f1-a3f2-811e9cce0584">
                        <link linkend="DCM_110824" xrefstyle="select: nopage">110824</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_bbb0f6e5-252e-44ca-b5b1-0da5f86fe63f">Spatial Displacement Z Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7f972996-d331-4726-af7b-38f773477431"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_15b21f8a-7132-43f7-91a2-a828981115e6"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2c7123c0-88bb-41e8-990b-eb9999ebe836">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a0101bb9-973b-4b55-a007-502e885df12b">
                        <link linkend="DCM_110825" xrefstyle="select: nopage">110825</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1975af89-7f47-4184-a96c-21b252341542">Hemodynamic Resistance</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_62212df3-9d54-45f4-ac57-736afd1e38c7"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_52b015da-eb0d-4cf2-87c5-6580b240b7c0"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4dfb690e-6aa5-4cd6-a8cc-cdb09645e5ef">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4df94807-3bf2-4f15-95d0-ac4722cce571">
                        <link linkend="DCM_110826" xrefstyle="select: nopage">110826</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c0507d2a-9c71-4020-98bd-b50f9f4cca26">Indexed Hemodynamic Resistance</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1602aed1-d624-4291-8d2c-6342b36e0fb7"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3a127681-61c4-4d3b-b7d2-96a03859a54d"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_80d73aa6-9696-4433-87e1-6eb683a637e0">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_23a0089b-3e98-4d0a-891d-637e0c51018d">
                        <link linkend="DCM_112031" xrefstyle="select: nopage">112031</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fbe5899b-bae4-4642-bcd8-951bbf9dccbf">Attenuation Coefficient</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7c4c87ae-fe6b-4b90-9a83-696c028198b1"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_26ddd687-6b2a-40f4-bb10-defa4eb8c5e5"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e0773c72-a491-42b0-a405-d11ef8b956a1">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ea326c54-a974-4717-a180-8701a5802990">
                        <link linkend="DCM_110827" xrefstyle="select: nopage">110827</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_06fa7a20-0ec5-4de0-a68f-a6c793435106">Tissue Velocity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6820143a-7f70-4991-9911-05163b99e5dc"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c17ef809-27bb-4892-b7e3-23a3e19e489a"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_355ab0a5-01fa-4d3a-be4c-4faf9d4702ca">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_82afd79b-acc0-4183-b4cc-485c5e3891f6">
                        <link linkend="DCM_110828" xrefstyle="select: nopage">110828</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fc930a0e-2614-4621-bd96-2633536d697b">Flow Velocity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_98b9ed0a-9674-46a9-8091-dd25cbcb2740"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_96f9f27b-b796-498c-814d-3f5f28aa73b3"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6296f646-989a-49f5-8a7a-19d178beb10e">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_503927bf-7011-422d-adee-388f03b892e0">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=425704008" xl:show="new">P0-02241</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_2a2626e0-ae1a-42fa-919a-6fe41f03dd45">Power Doppler</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1eda168a-a620-48e3-b798-534867b544ab">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=425704008" xl:show="new">425704008</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_223171c8-5f01-4fe8-a480-9c7513dbad09">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1960437" xl:show="new">C1960437</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7446e7fd-3de2-4b27-87eb-06dac6c028f7">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ae8c2cbd-73c7-4781-8fa6-d7051831295a">
                        <link linkend="DCM_110829" xrefstyle="select: nopage">110829</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1c46d408-3851-45ea-889d-bffcc6944701">Flow Variance</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e50a77c4-7daa-4cdf-b428-9b1a4153cefe"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_539658fc-24b2-41a1-9b08-9c1faf672fb4"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b8a1fd5c-f97e-4e68-8060-4dd53aa87738">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_50dcb981-129e-44f7-94bc-3eed9cf2b55c">
                        <link linkend="DCM_110830" xrefstyle="select: nopage">110830</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_987bf28e-e8cf-40dd-8d93-91a922b6b337">Elasticity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f211b4a2-60b4-4e30-9444-5c59476cc1d8"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_52340157-921b-4342-98c4-53e05310d15f"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d9a63205-b7a8-4151-abf6-ff867c690fee">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b9137a0e-4113-40f4-901b-d7e85590f105">
                        <link linkend="DCM_110831" xrefstyle="select: nopage">110831</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c0ebcca8-cbec-4b67-8783-990dab880eaa">Perfusion</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9fbc2fd8-f2bf-4e89-8f0e-551ec7092b3a"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e38eea61-9e80-4dbc-85a6-d8f0e67a4f29"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8130ba28-249d-4914-9986-2322bb0d23bf">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cc96e155-39be-4fc9-aa61-10c8314f9527">
                        <link linkend="DCM_110832" xrefstyle="select: nopage">110832</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b01c11e0-0f9f-434d-8957-c788c21ec4ef">Speed of sound</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8eb74f0b-5107-4d27-a6bd-241c0656f2c1"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_08f3b31b-a934-48a7-b73a-8abfeed6c2d6"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d97ff449-3da5-427e-951a-1fae91e1e61a">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f0afbeae-c32e-4f22-87a1-a3915b3433f3">
                        <link linkend="DCM_110833" xrefstyle="select: nopage">110833</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ec2ec813-d8ee-407b-bbd3-cdbca07c665e">Ultrasound Attenuation</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e87b04d1-5c43-4cf7-815a-441c6523a5d0"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3699aa39-2087-48b2-a051-aac5e3d35831"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b496a49-6b90-4031-8242-ad5553d5e3dd">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9035b251-06e2-492b-b1c2-fb9b8e09d262">
                        <link linkend="DCM_113068" xrefstyle="select: nopage">113068</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_64057c73-21d3-426b-baa7-5d210821a323">Student's T-test</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_699e1785-cb0c-4cd7-8090-5f74f04d0c68"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_63d77c38-71ac-4a83-8da0-7d97341420f9"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2600a557-a442-4ddc-96ee-aa2ed21c5d8c">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_da764da1-de1f-4bc9-ad65-52ab2871db04">
                        <link linkend="DCM_113071" xrefstyle="select: nopage">113071</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_38893922-8a36-4ba9-91d3-c3dfb805e43d">Z-score</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bc1705d6-f59f-4c85-8bd6-e7559c469703"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_174c0ab4-e888-47ff-b890-a74bcf26b204"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fbf909be-cd4c-467f-8c69-449e77b7b774">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_819d14f3-c5d0-42f6-afd6-e4edc1d236ba">
                        <link linkend="DCM_113057" xrefstyle="select: nopage">113057</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_85e4e70b-04d6-4ecf-97d3-1cde55988d99">R-Coefficient</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_51156369-bafe-477e-9733-78b9de6dfdaa"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_25ee25f3-3b83-4fc4-a693-f4924771e832"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ffddf1ea-78ec-4192-9614-25cceef8a7d8">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b89134d-4bd3-458c-aa27-bfbed43bc06b">
                        <link linkend="DCM_126220" xrefstyle="select: nopage">126220</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0c82777c-ebee-4496-b586-bb9d989d7fed">R2-Coefficient</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3badf90e-2399-4fd1-8691-5f533adb5e98"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aa4a5a7a-cd45-4117-b388-33044535905c"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_62050dca-61d2-478e-ae2b-3a314796467b">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_88e7dd28-bd74-48eb-9a69-20cbafd93093">
                        <link linkend="DCM_126221" xrefstyle="select: nopage">126221</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5c4cfe0f-f065-401d-bc91-57aae471ecab">Chi-square</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_60a3132f-8609-4993-8aed-eeda28cc7492"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e44c8796-f590-42b1-88f4-0d1be303e7e5"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3428ec64-d19a-45cc-96ea-f1a273128e1f">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_af7e33b6-5de1-4c35-b499-4624e1ba11ab">
                        <link linkend="DCM_126222" xrefstyle="select: nopage">126222</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_cd6fabe4-0e68-4001-8151-4f75b83a5a11">D-W</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8b59be11-c9f8-4d12-858e-f633a6655906"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_def6b415-245a-4dd0-9684-122d719213fd"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a33672a2-ba5f-4ff7-ba25-d1f209c7c92b">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1567b3a2-e10b-4499-88e2-ee4a1ed20e93">
                        <link linkend="DCM_126223" xrefstyle="select: nopage">126223</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3eb93c04-aaa5-4ddb-9e98-2d5bc4141116">AIC</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a62cbac8-5247-4d1b-842a-934e5c00ad24"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_771ba572-5f48-4d10-8be2-0f36bec91880"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6cc6a5b3-464e-4be7-93c3-65d44f299447">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_085381dc-7817-45dd-88be-ee7929e66947">
                        <link linkend="DCM_126224" xrefstyle="select: nopage">126224</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_26637ebe-4893-43a8-b507-84fbafa7eae6">BIC</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_201fa4d8-8994-4829-b4cf-4176cc812d7e"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ddfa0526-41bb-4f99-a184-b1f400971ada"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9dd3cc56-2208-4c81-bd00-5ed16bae5882">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_489fdc26-a09a-4e4a-b82d-abb1fbd55956">
                        <link linkend="DCM_110834" xrefstyle="select: nopage">110834</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0d71997e-d756-4d3f-9412-b05e989bd3b2">RGB R Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_da8f2856-187a-4430-a78d-8bc86ac05cb0"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fb645778-a796-484c-8c9e-60da7b7ab27c"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a8de326d-4442-4311-bcfc-8862adad07a3">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_86142989-27a4-4a04-a9be-e78aa8d36809">
                        <link linkend="DCM_110835" xrefstyle="select: nopage">110835</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_cfb26626-bf43-4ed4-af53-892d162d1deb">RGB G Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2f79911e-391f-4dd9-aca6-dd9b126bd05f"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e660fab3-8726-4a1b-b0cb-5811a7f505a1"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0972037b-ac2b-49af-85ef-237a7937d8c4">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7bdabe81-d99b-4c50-981c-5079209ee140">
                        <link linkend="DCM_110836" xrefstyle="select: nopage">110836</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1c0ff994-234f-49e2-a65c-2ef53956d0e7">RGB B Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b3ab4e21-bf17-42d5-a555-f0ee78dbce8a"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d58f4425-7e8c-4104-ad87-977c3ba870b2"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1da0deb4-bea5-473e-b6ba-84af9504d174">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_13cc74a8-fd18-479e-869a-b8191a8a9469">
                        <link linkend="DCM_110837" xrefstyle="select: nopage">110837</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c6ff7067-84a9-43e6-9126-2bc0305024bc">YBR FULL Y Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_76f433d4-e218-467a-afce-dfbf2871d232"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7854d0e9-4fcf-41c8-b9d9-587449cab612"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_77d204fe-7163-4338-850c-3ff565226668">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8aa160bf-6239-47c1-8000-7114406465c0">
                        <link linkend="DCM_110838" xrefstyle="select: nopage">110838</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_942fc18b-b82c-4f3e-b714-7512ab60b529">YBR FULL CB Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c8a8830b-a43a-47c8-b44c-0315fa95e4a4"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4b6397bd-6410-4bea-9b83-a15c4d77ccec"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_22554dd0-3e4a-42cb-b8a7-cda8b113da8d">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_65b37532-965c-40f1-91e8-5a0ddc96694d">
                        <link linkend="DCM_110839" xrefstyle="select: nopage">110839</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8f78dd8a-5ee7-4a6d-83f0-1a52d68a03f0">YBR FULL CR Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e197ecc5-6809-4667-b23d-52e0b0b5b47a"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f75f9e8e-3dd8-4120-a122-28552b376482"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8af18eb6-6047-455a-a6c3-2918725e3fdf">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_95cce5ed-a5a0-4b08-b527-8a924d54949f">
                        <link linkend="DCM_110840" xrefstyle="select: nopage">110840</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5678e6f9-cdb2-4ba3-9f21-4c9d8f06c778">YBR PARTIAL Y Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5d6a6b00-f404-4b76-96f3-8ba09262bb36"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_88ee7894-6798-462b-9607-b76cb748396c"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_968589b2-62de-440b-aba1-6d03099e1ab0">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5c9263d7-9e8b-4ba1-b823-531f5f0856b5">
                        <link linkend="DCM_110841" xrefstyle="select: nopage">110841</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d64d64d4-11f5-427f-ad3f-1889aa415960">YBR PARTIAL CB Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e8e864c6-7c5a-478a-863e-e9c4bebc6503"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5cb0b373-a275-421b-a252-cb14be5fece1"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4cfde86d-f9b2-482b-a594-d13ccdc8593f">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4cd4b3d5-6ec2-4bad-a788-07a0cf5bfe3a">
                        <link linkend="DCM_110842" xrefstyle="select: nopage">110842</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c2513bc8-b07b-491f-aa6c-035d3d88aa87">YBR PARTIAL CR Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7482a8c4-0174-48e8-91b3-887e9b69862e"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_83c46f60-4d96-4b71-bc4e-0a6db9ad15cb"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b8e83629-e8cd-47c4-aea3-2b69886220cf">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aa613389-79b3-4807-8284-09e7e1d7e0ca">
                        <link linkend="DCM_110843" xrefstyle="select: nopage">110843</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4a0e0662-7747-42a6-b23a-d3050914ce02">YBR ICT Y Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e0a863f2-7ff7-44d3-9773-e916606e9c50"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_10ed2ed4-9d23-4c72-bc3d-a5c0ff21f47e"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_571eece7-6016-4a92-b1b0-3bdcf9661cc0">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1f64dd00-97cb-410e-9de4-40382bd7074a">
                        <link linkend="DCM_110844" xrefstyle="select: nopage">110844</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_59d7bbbe-b4d5-4108-aa45-43295ada35de">YBR ICT CB Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_75420ff1-0f0d-46f5-b9c6-ef4fb71f4334"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_acee095e-9985-46c9-86e4-5c1964d3e441"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_419e6278-0976-437c-b757-dd321f086f6e">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0af0c8f0-597c-4220-bf91-7b5f3bdebbae">
                        <link linkend="DCM_110845" xrefstyle="select: nopage">110845</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c9a5617a-d431-4c0a-876c-5e132dbdff32">YBR ICT CR Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3bbd27d1-cb6b-47ad-a5c8-0f63fa90f313"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1fec688b-f109-47d4-b292-b9b87a410e31"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_566b9c5b-f625-4cfe-b784-c70e7bd72bdd">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b1ebae42-0e89-4251-9f03-48cde8c39a49">
                        <link linkend="DCM_110846" xrefstyle="select: nopage">110846</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7dc8c3f2-64d8-4722-849e-f75f1dd1c094">YBR RCT Y Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_65d4ba2b-cbcd-4f84-9596-a359885f9d66"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6aa08baa-6995-42f0-b553-8bb41aaf8b36"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ec06e5d-2ff1-4b1b-b04b-79f5cedfc75a">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_91a3a016-82bf-4b26-b90f-8a492b242728">
                        <link linkend="DCM_110847" xrefstyle="select: nopage">110847</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e19d679f-605f-41c5-bdba-8f56325eb913">YBR RCT CB Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ab675a2f-d875-4522-a651-837e94443e41"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_37b80701-db9a-497a-9659-56b911bb8813"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8f827879-6d6a-4a16-9c00-1fb1937b70f7">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7808d855-d674-453d-b127-f6e2a0d6149f">
                        <link linkend="DCM_110848" xrefstyle="select: nopage">110848</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_cc71a4a7-9d71-40ed-b78c-c48fddc1fef9">YBR RCT CR Component</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e1aa52df-f91f-4458-b04f-b527a8be724e"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5dddb6c0-3bf7-4bbd-9a55-48d93966fd0d"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_19ead338-5d86-4b4d-a080-83697a046633">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_21a83fa1-63ec-43a1-9234-1f4a4868fa1b">
                        <link linkend="DCM_110849" xrefstyle="select: nopage">110849</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_868c3701-4038-4e85-8aa1-5527fa196171">Echogenicity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_473e7304-da55-4443-9d68-4219ec207bcf"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4ad0af00-a9fd-4ad6-9f38-42892a304a3f"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c212b3a8-44d3-4909-ae31-b977fea13479">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_be08c41c-ebcc-4870-9823-fd4ba6bd5891">
                        <link linkend="DCM_110850" xrefstyle="select: nopage">110850</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4138c291-cc93-4326-bd9b-555ebf58ffec">X-Ray Attenuation</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1e5ac9cd-c9ea-4f5b-ac06-5c74fb7a8afa"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d355df8c-40b8-4dba-afe0-e60365274abb"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_745a8ed5-a02f-498e-9c19-1f4bd407dd1b">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6ee1b227-51c7-478f-acb2-b2ce2513e945">
                        <link linkend="DCM_110852" xrefstyle="select: nopage">110852</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3c4e74f1-ca9e-4d99-8509-26c4edee0f8b">MR signal intensity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_658c72ea-61cb-41e7-9a6d-68c69854a586"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1a0dd317-23df-43fd-adb5-517389bed9f6"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7966fe48-06ad-47b3-832d-233ec17fa4fc">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e39b61ac-c529-49e7-84e1-b602100312b4">
                        <link linkend="DCM_110853" xrefstyle="select: nopage">110853</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_59104bc3-19ea-4b6f-847f-0a69a7665427">Binary Segmentation</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_67dd93a2-62d8-46b7-aaed-9f817057a385"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_910fd9f5-35e6-4248-8c87-ed39eb4177bd"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5c851274-f044-4787-a7a3-bca90c576cd2">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5517d51d-bc60-4104-84dd-7833a74db480">
                        <link linkend="DCM_110854" xrefstyle="select: nopage">110854</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_650e97c1-1b56-4b08-9f89-fb0b109d20ef">Fractional Probabilistic Segmentation</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_084fb7f7-9ce0-4cae-a631-35f418a92725"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9b690eb2-5f1b-4e29-92d3-9bd0158e4328"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_447a78d5-b51b-494b-90cf-56c90ea2bafd">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5361ad94-025a-43c2-8b5b-5c38fc490683">
                        <link linkend="DCM_110855" xrefstyle="select: nopage">110855</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_bd75eb66-6169-47a7-b3df-3381b34e967f">Fractional Occupancy Segmentation</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_71f39dd2-0ab0-43ea-8119-e7404b14eb6e"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5aba2e67-e4a7-44a9-a7c2-6f200e8c1a49"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e95412f3-b1eb-4dc1-8207-53a874edc764">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b2325cb0-970f-470b-b5c6-c5def0a952de">
                        <link linkend="DCM_126393" xrefstyle="select: nopage">126393</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1e131b50-ca29-4e92-9bdd-7c474b531e60">R1</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6c2af2fd-fb81-4eb0-983f-8cc7d1ab856a"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2584d5de-5745-4785-9bba-60968ef7d6ae"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9bc92d12-3f8e-4397-a90f-97c30cd1e6bd">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6e8bf004-c086-448b-81fa-cecba9124bc5">
                        <link linkend="DCM_126394" xrefstyle="select: nopage">126394</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d12b4182-5e1d-4165-8f6b-38dfab502889">R2</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aa9bb1c1-6aae-4062-91ac-8b526609d1c1"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5dcfe624-ea8c-470b-baa0-24caa1f86c09"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6d10f0a4-0e8b-42d9-bdf9-33bae06c2f73">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6529d7c6-8bee-493c-ac06-172d8a71d44c">
                        <link linkend="DCM_126395" xrefstyle="select: nopage">126395</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_212e804e-ad5d-456b-b0ce-2e48cf39eaec">R2*</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_46fa55f9-7d2d-408e-88c1-59c852e7f86b"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4c811bea-72bb-43c1-9be2-cd34851f2568"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1be36c6c-7fb8-4b5f-a0d0-f3a2c746cca0">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ba602f82-00fa-4874-991f-2684fd3e9aea">
                        <link linkend="DCM_113098" xrefstyle="select: nopage">113098</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6689ad87-de1f-42b6-8520-96d1bf928c3d">Magnetization Transfer Ratio</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ce4cd494-56e6-4599-b9c7-1280e56bdb7e"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b3907c0b-4074-490f-bf25-b6e2b2f41778"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3eaa788d-77d3-47be-b640-1ef748435252">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6629b665-45dd-48ad-a438-ed76d2edcec2">
                        <link linkend="DCM_126396" xrefstyle="select: nopage">126396</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f1744d8f-7334-45e4-8354-9383a4219e06">Magnetic Susceptibility</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4c089cbb-f7ab-412e-aa66-ca88a15c6eca"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ba06e82d-1289-466e-9dce-ff28b459098b"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_64752f65-03df-4d40-a5b4-173e76c106f7">Include <xref linkend="sect_CID_4107" xrefstyle="select: label quotedtitle"/>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_94905a3c-befd-432e-9f0e-8173f0345836"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_89f49e7e-31bd-4e9f-b06c-d6ff42fcaa9c"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_c60a70a5-360c-4818-9999-662d69db7b48">Include <xref linkend="sect_CID_4108" xrefstyle="select: label quotedtitle"/>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2cd99357-6bf4-4b0a-85c0-dabecc3ae9f4"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d9f2518a-304e-4892-a465-02f195170e96"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_22107b47-2df1-4a8b-aa34-a5ba8fe8ebc4">Include <xref linkend="sect_CID_4109" xrefstyle="select: label quotedtitle"/>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6cd23445-2578-40b9-935e-4a09458d8ad0"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b3235e2c-d190-43b6-b2e7-96658cea9008"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b8dea7f1-0449-4ab7-94e5-66f3b9f93711">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_74c43ea3-9782-4302-8991-631654c550d4">
                        <link linkend="DCM_126400" xrefstyle="select: nopage">126400</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a02ed2bf-f7e6-4d9d-aff8-147d55a253ba">Standardized Uptake Value</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7bd9ca2c-5ec2-4e88-af5c-6ee6d046cfdb"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_76c6c235-bbd0-4544-88ef-3b283f97d568"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e0df5a00-f41b-4ea5-ac8e-c7c9aeb90fdf">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fb3e139e-3e47-4e01-83c1-86001d27e471">
                        <link linkend="DCM_126401" xrefstyle="select: nopage">126401</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_003b8be2-d677-49cf-8154-c6c942d2dfa9">SUVbw</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_92f9b047-c173-4c6f-a87b-727be40cdab1"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e60a6ca7-ab71-48e2-8ad5-c7d0a73692a5"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_435ebcf3-1a36-497d-a80e-db65a4513377">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3d1d0cd3-6d16-4065-ad3f-550b366bf1b9">
                        <link linkend="DCM_126402" xrefstyle="select: nopage">126402</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6364c99b-6145-4061-b28f-90ffd14fdba5">SUVlbm</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_138384e7-53a3-4090-bd76-60a6da82b6c1"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1adece85-9dcf-4604-b5c1-b71934b5ef73"/>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1">
                     <para xml:id="para_b5f526bc-b35a-4dac-ac91-c7a6c99b689e">DCM</para>
                  </td>
                  <td align="center" colspan="1">
                     <para xml:id="para_003dcacc-5033-4b30-aa29-21847e87b589">
                        <link linkend="DCM_126406" xrefstyle="select: nopage">126406</link>
                     </para>
                  </td>
                  <td align="left" colspan="1">
                     <para xml:id="para_342e43e9-6c01-4add-a57f-211d626fa799">SUVlbm(James128)</para>
                  </td>
                  <td align="center" colspan="1">
                     <para xml:id="para_7abda1c5-d71a-4b12-823b-6006ad3e27e0"/>
                  </td>
                  <td align="center" colspan="1">
                     <para xml:id="para_8f7a8249-49f7-447e-a851-36325d2cafcf"/>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9f363f29-4d85-4c52-8772-e32c71f628ad">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0d362d33-f819-45e7-9f3c-21eb9fe2a850">
                        <link linkend="DCM_126405" xrefstyle="select: nopage">126405</link>
                     </para>
                  </td>
                  <td align="left" colspan="1">
                     <para xml:id="para_ae1bd081-7265-4bdf-9415-07af56172422">SUVlbm(Janma)</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_11808b23-5fb1-4368-a1b8-4cfaba2a27b4"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_28196738-0fdf-4363-b71d-170580333faf"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4bd42f16-aa32-4718-980e-3b2f27813b2f">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_34d397be-8ce8-4cef-85ab-fba866445cde">
                        <link linkend="DCM_126403" xrefstyle="select: nopage">126403</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f0cda444-15ae-4c68-8c5e-8f85026a38e1">SUVbsa</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ae8ac368-04a5-415d-af19-3ea4359fefbf"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_61a60f7b-f4c0-42e2-ba43-e9bc817f1b35"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2da213d2-386c-495b-9073-b6800ee7ab6a">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_35cd9883-6f23-470a-96d7-82c174fa6482">
                        <link linkend="DCM_126404" xrefstyle="select: nopage">126404</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fbcc5948-cbf1-45fe-86c7-d883ac332824">SUVibw</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_69a96770-a341-4c46-acd1-5f4b89b83a0c"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2ed14e3d-3752-4afb-8f8f-f6b53fd883dd"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_94756dde-5d87-4594-b045-9a2ff1dc047e">
                        <emphasis role="italic">Include <xref linkend="sect_CID_10070" xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a739816e-5aed-4820-9a65-2a49a1cbc027"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e4de9af3-d50d-4330-912f-12fd454b1e77"/>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>

      <section label="CID 4107" status="3" xml:id="sect_CID_4107">
         <title>Tracer Kinetic Model Parameters</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_136dc1fe-ac3b-49d0-9b76-ffcb0ebfe3b1">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_4107.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_4107.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_4107.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.992.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_3de405ec-09e9-4782-afeb-612b661fadc4">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_d668f5da-c664-42b8-a0dd-80438cb8a2b9">
                     <emphasis role="bold">20141110</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_c8f7b098-d259-4c6a-bd77-13d8e4681fc0">
                     <emphasis role="bold">1.2.840.10008.6.1.992</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 4107" rules="all" xml:id="table_CID_4107">
            <caption>Tracer Kinetic Model Parameters</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d199c90d-9b2f-4f27-b501-9997dbcadae4">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_78542d71-df00-4b97-8d62-5e7ad3f23698">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7983e12d-1647-400e-ad29-ecd9b5989120">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a4215197-97f4-4380-b859-8ffd9a00635b">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4ebcd6f2-c185-42f2-8795-3711fdc297c3">
                        <link linkend="DCM_126312" xrefstyle="select: nopage">126312</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5e9010ad-d3c4-4375-ba15-0c5a8f7985fb">Ktrans</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8429f8d2-e5be-4807-ac89-64029d309bd2">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b785f7ed-2b9d-42fd-9612-519a192b8f3f">
                        <link linkend="DCM_126313" xrefstyle="select: nopage">126313</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3602da80-f512-4e94-a273-523e06f4ab97">kep</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_138b64b2-612b-4ef2-b712-2c91d7ed5fc9">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d95350c4-4620-4daf-8fd2-603e195a815d">
                        <link linkend="DCM_126314" xrefstyle="select: nopage">126314</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0fb0dfc9-da58-45df-8fcd-fc301a5cdfdf">ve</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_da557706-07ba-461b-b857-abba517fda16">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8b07883d-963c-4a99-bfb8-371765461b8e">
                        <link linkend="DCM_126330" xrefstyle="select: nopage">126330</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_60787ea2-8bda-4579-8ad4-308ce9332802">tau_m</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3ca3fb25-d5fe-449a-8a33-2e08dce6849b">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_794870dd-fd97-445b-9bd9-4dab9c97c585">
                        <link linkend="DCM_126331" xrefstyle="select: nopage">126331</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9e5e4dee-9071-4a9a-95e7-f5547cf8be2b">vp</para>
                  </td>
               </tr>
            </tbody>
         </table>
         <note>
            <para xml:id="para_e274841a-85db-47a3-97be-b02513011242"/>
         </note>
      </section>
      <section label="CID 4108" status="3" xml:id="sect_CID_4108">
         <title>Perfusion Model Parameters</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_bf5b0a37-4128-4326-a44e-b868e0d50428">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_4108.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_4108.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_4108.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.993.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f1b308fe-e7d2-4ee6-a0e8-29e222a49471">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_5f37510c-8a73-4762-b511-c39f7f3df39b">
                     <emphasis role="bold">20161106</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_48dd8aba-d2db-4e2a-b0d0-cc369859872a">
                     <emphasis role="bold">1.2.840.10008.6.1.993</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 4108" rules="all" xml:id="table_CID_4108">
            <caption>Perfusion Model Parameters</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_557b7bd9-9a1e-4d01-bac8-46f1a1dd5382">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a0a450d4-fcac-4379-972a-d1fcf50967ae">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5ef61c06-dc4e-4345-bf96-373332108ee8">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d029919a-35a7-4dc5-95d8-c45c0eda6aee">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_30fbad15-bd9d-422b-8709-5a8cb967d394">
                        <link linkend="DCM_113055" xrefstyle="select: nopage">113055</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_129cb867-4579-425c-a1e4-5931daac17ad">Regional Cerebral Blood Flow</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3e129d12-feab-4a1f-925d-db446484fd37">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7ef4a625-ba48-4533-9402-19f3c76dcba3">
                        <link linkend="DCM_126390" xrefstyle="select: nopage">126390</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_77f952cc-bd14-4c0b-ae73-a1b249fd5fc9">Regional Blood Flow</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aa8a581b-43d4-46a0-9642-d67778916242">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e200f3b1-4c62-4977-a49d-5c6e53844733">
                        <link linkend="DCM_113056" xrefstyle="select: nopage">113056</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_164fccb9-624a-4181-8593-2fdf1f3b4ca4">Regional Cerebral Blood Volume</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0387e41b-a224-443b-b8a4-dc7cacd56894">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fdf5f37b-e9b5-4348-9131-8b3869b297ce">
                        <link linkend="DCM_126391" xrefstyle="select: nopage">126391</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_bdf40dd5-eb22-493d-bd67-84bd451b9bf2">Regional Blood Volume</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b4876098-843b-43b3-945a-6498231b883e">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_39fafc4f-842d-43d5-8299-9d0e7c054b8a">
                        <link linkend="DCM_113052" xrefstyle="select: nopage">113052</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5f522556-f6d7-4cc7-81fd-0e3db0a31998">Mean Transit Time</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d06dc4cc-a42c-4e1e-989a-29bddc42b73e">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3441fbde-c11a-43fa-ba67-22605c236c9a">
                        <link linkend="DCM_113069" xrefstyle="select: nopage">113069</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_dc96aead-09b9-4da8-a5db-155e7124a3ce">Time To Peak</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ab5e5273-6acd-4f8a-be14-bb57e9130589">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_52aee42a-5dfe-45c3-a4d4-9c293e4a6229">
                        <link linkend="DCM_126392" xrefstyle="select: nopage">126392</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9a0e5788-0b1d-4856-a3ef-13221f37cc23">Oxygen Extraction Fraction</para>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1">
                     <para xml:id="para_3fd9f988-4542-4f89-aaf4-3180dc8798b9">DCM</para>
                  </td>
                  <td align="center" colspan="1">
                     <para xml:id="para_b1fd2cad-c706-4a7a-8e14-596e11997f1d">
                        <link linkend="DCM_113084" xrefstyle="select: nopage">113084</link>
                     </para>
                  </td>
                  <td align="left" colspan="1">
                     <para xml:id="para_5562a54b-cf1a-4322-9a89-cd8894738c99">Tmax</para>
                  </td>
               </tr>
            </tbody>
         </table>
         <note>
            <para xml:id="para_9a7e00a2-7d2e-4664-9e51-caa0811616ba"/>
         </note>
      </section>
      <section label="CID 4109" status="3" xml:id="sect_CID_4109">
         <title>Model-Independent Dynamic Contrast Analysis Parameters</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_bafa435f-576f-44d5-9de2-51ece13b17d9">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_4109.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_4109.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_4109.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.994.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_88c21ac4-1337-4eaf-9a53-8f787086375e">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_23b3e22b-315a-40f4-9091-f398d00dab2e">
                     <emphasis role="bold">20150916</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_5322e0c9-da93-4f57-88e3-c3206ee04c44">
                     <emphasis role="bold">1.2.840.10008.6.1.994</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 4109" rules="all" xml:id="table_CID_4109">
            <caption>Model-Independent Dynamic Contrast Analysis Parameters</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4c3bf427-5d51-4237-9d48-126eb544f451">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ffe619cf-4a44-486d-bb4d-18d2ce00d796">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_eba49b12-2f0e-440b-9f13-7ab930632b6d">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5f49d601-825c-408b-a49c-3b13f65cc801">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_73020a9e-6fe1-4c6a-88f8-3adcc7bd834e">
                        <link linkend="DCM_126320" xrefstyle="select: nopage">126320</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fd54492e-ac45-484c-a557-98af77414e79">IAUC</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2df69eef-8ccf-485b-8776-1b980b70ff68">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f9bff06b-2932-4f69-ba04-2a1ce720a840">
                        <link linkend="DCM_126321" xrefstyle="select: nopage">126321</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_066ae5e2-c159-4e90-81eb-235ffeac0757">IAUC60</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_321b6f3f-c2b7-46fd-a789-488440dd964d">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_23e66687-f96d-40d0-992e-80975f516df6">
                        <link linkend="DCM_126322" xrefstyle="select: nopage">126322</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7618ec18-8e99-4db5-be76-d5f1fd33d3aa">IAUC90</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4c9d0c6c-fa0a-4799-977e-7b0ad53315f4">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0e007a69-13d9-40e6-b60c-736535570a78">
                        <link linkend="DCM_126323" xrefstyle="select: nopage">126323</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_61b82be7-9a0b-4f41-98b9-a12ab14f402f">IAUC180</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_717a323f-64bc-4eaa-98b5-2c6ba561b679">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_423da180-97b5-449b-a99d-a598db534532">
                        <link linkend="DCM_126324" xrefstyle="select: nopage">126324</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_905dfeb1-4ef7-461b-9fbe-a3e2780cdae9">IAUCBN</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5a0a07ba-7a88-4984-93a6-32e73bfa5f36">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_43642127-0230-4325-9df0-0cb1823a45ba">
                        <link linkend="DCM_126325" xrefstyle="select: nopage">126325</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8bbf6be3-f249-43b0-bfbf-ed0d1fdc23b9">IAUC60BN</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a47c196c-8ee1-47b9-8eed-434bdec302b1">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3dbc1f14-8531-491d-bc16-f1757bd100f3">
                        <link linkend="DCM_126326" xrefstyle="select: nopage">126326</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_98a6a12c-31e9-4a55-b677-d450015d4dfa">IAUC90BN</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_94b4b338-2042-427a-9765-50f98fce5dd2">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3c418693-f376-490f-985a-c5066ef51850">
                        <link linkend="DCM_126327" xrefstyle="select: nopage">126327</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e564ffab-ec0f-4b24-87d2-5d0e099491da">IAUC180BN</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf443fc4-dffc-432c-b25a-237fb2fe578e">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_21da9786-a067-4a07-8a25-ed02b277c76c">
                        <link linkend="DCM_126370" xrefstyle="select: nopage">126370</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d73993d7-5c75-42f3-a36e-882d002fcd7c">Time of Peak Concentration</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2cc41422-ca75-4938-966c-998570887ee3">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cd5433d5-7e0f-46d9-ab27-f2fbfba2536f">
                        <link linkend="DCM_126372" xrefstyle="select: nopage">126372</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3810adb9-1645-4364-8e7f-c741e9d8201e">Time of Leading Half-Peak Concentration</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5681bb79-ac17-4f41-a381-6c50b91d88e1">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bc7ec495-500f-4d42-9aca-9ff89f580918">
                        <link linkend="DCM_126371" xrefstyle="select: nopage">126371</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_68fe4665-2b4e-405f-8f6b-44ae56720468">Bolus Arrival Time</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c3aeede5-c2c8-422b-b098-4b0384b6cca8">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_67df0f07-e522-43c0-a6e1-5ad0e20bc6ca">
                        <link linkend="DCM_113069" xrefstyle="select: nopage">113069</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d3da9f8f-7e73-4205-bf85-11815c0853d3">Time To Peak</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_48209890-3d42-4230-a8d0-d93b98b514ab">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_acbb1e49-4b17-4e96-9074-75abe74c9e04">
                        <link linkend="DCM_126374" xrefstyle="select: nopage">126374</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_654c11b6-c4c7-437a-bc71-cf76bc04d7d7">Temporal Derivative Threshold</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_95710b36-4292-4efd-87f7-90eb0fa4507d">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf78026d-f079-4624-87a6-2172086ee79b">
                        <link linkend="DCM_126375" xrefstyle="select: nopage">126375</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d7ed48a9-cf89-4a45-b1ab-992cefbc2621">Maximum Slope</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1355ccad-b7f4-4e20-aa97-7e2da211e6de">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a27ef0f6-775e-4445-8457-2e107805a55e">
                        <link linkend="DCM_126376" xrefstyle="select: nopage">126376</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_049d23ba-00f9-4428-86ed-4e2c336419ef">Maximum Difference</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2b18ef39-6117-4293-a11e-cc8d7aaf3a92">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1459af1e-266a-4d23-9889-66f896213a22">
                        <link linkend="DCM_126377" xrefstyle="select: nopage">126377</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a5d05c3e-42f6-41c6-9d22-d1f298559f36">Tracer Concentration</para>
                  </td>
               </tr>
            </tbody>
         </table>
         <note>
            <para xml:id="para_f8c9bd6a-1f92-40a2-9ce2-9458debe9b3d">
               <link linkend="DCM_126326" xrefstyle="select: nopage">(126326, DCM, "IAUC90BN")</link> can be used for DCE-MRI using a Gd-based contrast agent to represent the IAUGC<subscript>BN</subscript> measurement in the claim of the QIBA DCE MRI Quantification Profile, though the concept itself is not specific to the modality or the contast agent used. See <link xl:href="http://www.rsna.org/QIBA_Protocols_and_Profiles.aspx"/>. See also Ng, CS., et al. "Reproducibility of Perfusion Parameters in Dynamic Contrast-Enhanced MRI of Lung and Liver Tumors: Effect on Estimates of Patient Sample Size in Clinical Trials and on Individual Patient Responses." <emphasis role="italic">AJR</emphasis> 194, no. 2 (February 1, 2010): W134–40. <link xl:href="http://dx.doi.org/10.2214/AJR.09.3116"/>.</para>
            <para xml:id="para_1e9f056b-13ba-4126-a227-7fee735903b9">The type of contrast agent and the AIF used for blood normalization may or may not be post-coordinated.</para>
            <para xml:id="para_26d3db09-30e1-42be-9b6d-e18eb10ac704">E.g., voxel-wise IAUC<subscript>BN</subscript> measurements encoded as a parametric map with the quantity defined by the Quantity Definition Sequence (0040,9220) in a Real World Value Map might be encoded as:</para>
            <para xml:id="para_ff32751f-4252-4ab6-aafa-83e69e55d0f8">
               <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=246205007" xl:show="new">(G-C1C6, SRT, "Quantity")</link> = <link linkend="DCM_126326" xrefstyle="select: nopage">(126326, DCM, "IAUC90BN")</link>
            </para>
            <para xml:id="para_dbb783ff-7e52-41df-8c3c-fb918cb16440">
               <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=370129005" xl:show="new">(G-C036, SRT, "Measurement Method")</link> = <link linkend="DCM_126362" xrefstyle="select: nopage">(126362, DCM, "User-defined AIF ROI")</link>
            </para>
            <para xml:id="para_c29b28fe-4306-4e32-bea7-feac456c390a">
               <link linkend="DCM_123011" xrefstyle="select: nopage">(123011, DCM, "Contrast Bolus/Agent")</link> = <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=58281002" xl:show="new">(C-17800, SRT, "Gadolinium")</link>
            </para>
            <para xml:id="para_2224816f-5836-4b99-a4e9-68ec69429462">E.g., an IAUC<subscript>BN</subscript> measurement for an ROI encoded in a structured report might be encoded as:</para>
            <para xml:id="para_2e2980d4-d157-4929-ba9e-6bf24493ad72">NUM <link linkend="DCM_126326" xrefstyle="select: nopage">(126326, DCM, "IAUC90BN")</link> = 0.230 (UNITS = ({normalized}, UCUM, "normalized")</para>
            <para xml:id="para_d47ddad4-723a-4964-8018-1e8e95efa7ea">&gt;HAS CONCEPT MOD: CODE <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=370129005" xl:show="new">(G-C036, SRT, "Measurement Method")</link> = <link linkend="DCM_126364" xrefstyle="select: nopage">(126364, DCM, "Blind Estimation of AIF")</link>
            </para>
            <para xml:id="para_f77a1dcb-8ce3-4a77-87b7-bf95b77fd2cb">Note that the generic ROI measurement templates do not have the contrast/bolus agent as a parameter; this may be implicit from context, or inherited from the (<link linkend="DCM_121058" xrefstyle="select: nopage">121058</link>, DCM,"Procedure reported") in the parent template.</para>
         </note>
      </section>
        
        <section label="CID 4033" status="3" xml:id="sect_CID_4033">
         <title>MR Proton Spectroscopy Metabolites</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_afc099cb-5d79-4c3e-8d95-e8222e3d5de2">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_4033.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_4033.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_4033.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.310.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_99f54f5a-9bfe-4d47-9ec0-6f01b5876533">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_c1511745-08c8-466b-b7f8-def98c690d0e">
                     <emphasis role="bold">20160314</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_e87f722c-923b-439b-817e-35716c8b5a09">
                     <emphasis role="bold">1.2.840.10008.6.1.310</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 4033" rules="all" xml:id="table_CID_4033">
            <caption>MR Proton Spectroscopy Metabolites</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ac614b3d-b818-4268-8779-1b72450274e0">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_36dbe836-9ace-4228-8892-17986b3b7c93">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2e59b938-fccb-4bc8-935b-f11c2c003d84">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d18b589f-f637-40a6-8cd8-f116b8c59393">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_66723d41-cad9-4fbe-9e02-22bb523e84ea">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fcb45a04-76de-4279-ae99-9b3c907e2259">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6cc0cc38-3034-4ff4-842d-bd47d25c9f25">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=115391007" xl:show="new">F-65C50</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6382d4a0-3cc9-4d90-b53c-732139f175e7">N-acetylaspartate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ee9f8af4-feb0-4f70-859c-1fc1af6df976">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=115391007" xl:show="new">115391007</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d782320d-941f-4ef4-996b-07b6b242eef0">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0067684" xl:show="new">C0067684</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4a9d3c9b-b8d1-4698-aef1-821b371a0238">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5b811d73-0a26-4498-aa2b-805fd6d78cb3">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=59351004" xl:show="new">F-61080</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_08fcfa46-d860-4dad-a611-38f59e48f391">Citrate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c9fd4cca-5dab-49e6-bdf6-bb7db153a9f7">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=59351004" xl:show="new">59351004</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b5f4d8cf-325d-4b31-9db2-0e703e37121b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0376259" xl:show="new">C0376259</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a7b6f90d-b135-4af9-b307-b59257d33b77">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_386c13f1-86bd-4ac6-8dd8-ff3713fcf482">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=65123005" xl:show="new">F-61620</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_49611ee5-9594-479d-b10d-756999bc214d">Choline</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_199c3d8c-adec-4eae-ad88-66afde6fd53f">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=65123005" xl:show="new">65123005</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_25444a10-ce93-41e9-a250-4f6871484cc1">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0008405" xl:show="new">C0008405</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a02aae61-3190-424e-99a6-9d2e7e8b3610">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4223d4a2-4717-481a-9f74-c960ea4bfe25">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=14804005" xl:show="new">F-61380</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fadbe72b-2e0c-4c9b-b00e-95f147bf0b77">Creatine</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ca8c1021-cbdd-4cda-8cb2-6706cc632891">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=14804005" xl:show="new">14804005</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e2dc3f02-543a-4257-9760-893619b9a259">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0010286" xl:show="new">C0010286</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b08d2b90-b758-43e3-9b52-a20c1cd387bb">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_79799cc7-8281-4164-8390-810f75a711e8">
                        <link linkend="DCM_113094" xrefstyle="select: nopage">113094</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_90954a00-8b6d-4a60-b026-0e40e958b71c">Creatine and Choline</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_69bf0fbf-d17e-4483-9ede-147e8d4e3dbc"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2f2d527d-6ea4-4c75-977e-bb95ee20a2d5"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b979670f-c78e-4a95-b18f-f9d3724f320d">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2f6c5888-2cc9-495e-8187-e3d7d2db7a9e">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=83036002" xl:show="new">F-61760</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_10937600-445e-4439-9b37-093028807910">Lactate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_85d26bd7-d263-4817-b5e9-915c62f9cf85">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=83036002" xl:show="new">83036002</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_25e09098-d68e-4d72-b687-a1f44a0721c7">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0376261" xl:show="new">C0376261</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b19310ff-44ca-4768-863c-6975eb781174">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_51747949-7535-4c08-aef8-6302076a583b">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=70106000" xl:show="new">F-63600</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_74dbe201-5e65-45d1-ae8c-6210ef2bafd3">Lipid</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c88dc335-9292-4b43-966f-190be4ae5134">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=70106000" xl:show="new">70106000</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d75e81c3-1282-45e0-86ed-0f1ed0d96564">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0023779" xl:show="new">C0023779</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4567f425-5e15-4288-a8aa-7b211ba949a5">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a7f5a9a8-67af-4609-9ced-ebc0622a243b">
                        <link linkend="DCM_113095" xrefstyle="select: nopage">113095</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_75b85ca9-bb4d-4515-b200-21a3d4b74e13">Lipid and Lactate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_77f9a368-727a-40ff-8e7d-5b5dc232d025"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d8d42bf1-e37d-43ef-9fac-8528afac03ee"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_37742ff8-a10b-4197-9989-00ad9e75d009">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8e5c2550-e96f-4935-8f7d-d15405770db5">
                        <link linkend="DCM_113080" xrefstyle="select: nopage">113080</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_96df0f48-e342-407a-aab8-b8556db1927d">Glutamate and glutamine</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b6be5a15-0fca-4c3b-98f5-2ba7b760202d"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_222e0bae-c320-48d1-bf70-aaf7e8991b81"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9934e66c-d24c-4e4b-a1a0-1dc628ce4cf9">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2a64b737-c090-41e4-8698-50988484d61c">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=25761002" xl:show="new">F-64210</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_645ed203-2afc-4cf3-8981-6905d91787ff">Glutamine</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_24b79ea7-568f-49ea-aa1a-84e2cba5f6cb">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=25761002" xl:show="new">25761002</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_23637c20-34be-467c-a5e0-f7b8a9f055f9">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0017797" xl:show="new">C0017797</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a75ac359-70ea-43c9-b12f-723057d92090">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_906dd80b-36af-45f6-bc1b-9d1d436da6c2">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=10944007" xl:show="new">F-64460</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a3cb1bad-c257-4589-8418-87e1d8a27c09">Tuarine</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f2e6718f-497a-4650-bdbd-dd99a8711342">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=10944007" xl:show="new">10944007</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a4f640ba-1743-4ad6-afba-a9fe746bc11d">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0039350" xl:show="new">C0039350</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ea02e260-44ba-4a5b-80f4-ad534f9c5c15">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_edc4c19b-96ac-4fad-9e8b-921880c65844">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=72164009" xl:show="new">F-61A90</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_56a43a49-0982-49a1-9777-27ed58ed5b2a">Inositol</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c31fd769-0467-4053-b4bd-91c247c3c0a4">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=72164009" xl:show="new">72164009</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f9a97132-ef1f-4d13-85c3-0f71fe8b3630">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0021547" xl:show="new">C0021547</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b62a03b8-bb0f-4455-b912-83515ddbf254">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5e299daf-ee50-4266-86f2-2570f708efc4">
                        <link linkend="DCM_113081" xrefstyle="select: nopage">113081</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_15c81097-17f0-45a4-9057-6434d1ae225a">Choline/Creatine Ratio</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4336e120-d395-4cc9-93c2-d5aca2e66e24"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_39e375b9-844d-46e5-aa62-5f78ed9ccc6f"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d0066e5d-d961-42d8-9b41-559faef790b5">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0e2828c9-2c89-4a9d-8963-2d13a176beff">
                        <link linkend="DCM_113082" xrefstyle="select: nopage">113082</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_17d7b231-9116-424f-aaa5-3ecb2a2501e5">N-acetylaspartate/Creatine Ratio</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8eb889b5-9017-442d-9a00-ca88be8dcb48"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1911db63-9a7b-450b-8a6e-1b14bc8cc4cb"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_73ccd522-7597-4989-8ba4-15d30fc52e8a">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f48a9d75-4732-454b-ac60-9e27e5b73fb5">
                        <link linkend="DCM_113083" xrefstyle="select: nopage">113083</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a2b2c68f-0624-4d71-b88f-dc0edf81c0ce">N-acetylaspartate/Choline Ratio</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6147a786-e450-458f-855e-dc0642d2c789"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c579cc60-65dd-4f86-87b3-eb04979c8296"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aa2e197a-f858-4577-a313-7776f7d2ab05">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ea5c6a54-1af5-4770-a182-a0a36ecc372a">
                        <link linkend="DCM_113096" xrefstyle="select: nopage">113096</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_019e0b62-4566-4834-ba29-b833a73b7589">Creatine+Choline/Citrate Ratio</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8164412a-cd2e-4faf-a1df-be2f4e44c965"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5d435340-e743-4c40-9c2a-ef15125f33f7"/>
                  </td>
               </tr>
            </tbody>
         </table>
         <note>
            <para xml:id="para_48f28b79-a89d-4586-b362-6edb12977ab4">For the purpose of this context group, where possible, the resonance peak in the spectrum corresponding to a particular metabolite is described using the concept from SNOMED for the substance corresponding to the metabolite. E.g., the code used for "lipid" is the code for "lipid (substance) ", as this concept is effectively post-coordinated by its use in the Metabolite Map Code Sequence (0018,9083) to mean "lipid resonance peaks in MR spectroscopy".</para>
         </note>
      </section>
        
        <section label="CID 10070" status="3" xml:id="sect_CID_10070">
            <title>Radiation Dose Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_9523932a-08cf-4b62-b75f-bdcdb4fef655">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_10070.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_10070.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_10070.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1164.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_860fe0a9-03ee-4feb-9814-271ed06b4fdd">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_48c49aac-90a5-4fd7-9b16-1a77f538741c">
                            <emphasis role="bold">20170405</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1e1bdc19-e530-430d-8772-b9cb5921f359">
                            <emphasis role="bold">1.2.840.10008.6.1.1164</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 10070" rules="all" xml:id="table_CID_10070">
                <caption>Radiation Dose Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8273a815-7580-4d9a-85fc-3fbc4903ccfe">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66bd1a6f-a483-4866-a9d1-1b5abee46aa2">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11b245a8-80b5-4df7-9e35-4de68d690325">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6bf095e-4f96-4feb-a8d5-15162e574eee">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a501e2b-438b-4e65-972b-c5c2ee99b99f">
                                <link linkend="DCM_128513" xrefstyle="select: nopage">128513</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b5a88e8b-abe5-4f92-a9d1-e4d6fe74ba70">Absorbed Dose</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_13487ac5-eafc-4f7b-a18a-46b96a3ba186">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f0fa36f-41d2-4cf6-80c4-e09f9d8df6f6">
                                <link linkend="DCM_128512" xrefstyle="select: nopage">128512</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7ff336d5-531a-468a-b476-3c642aa2cef1">Equivalent Dose</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="CID 7270" status="3" xml:id="sect_CID_7270">
            <title>MR Diffusion Component Semantics</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_198a31cb-4644-4c4d-85c7-ea6a76ff0094">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7270.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7270.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7270.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1165.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_75177e83-50b7-4695-9ba7-03b23ee360a0">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_40efd55c-3354-4193-94ae-1c6dbe89ea27">
                            <emphasis role="bold">20170413</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_4451ad8a-e4b0-4c59-b5a6-08053be30eb4">
                            <emphasis role="bold">1.2.840.10008.6.1.1165</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7270" rules="all" xml:id="table_CID_7270">
                <caption>MR Diffusion Component Semantics</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da272415-9f03-440d-bc29-c323189bf412">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fe6f9aef-527a-48e0-989e-891ce99b7590">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8443cd4-3bbb-4bdf-82ba-82ff92692119">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f614a6a0-e72c-48c6-9a06-3f00e1ee46b0">
                                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12c624b3-92e3-446c-a2a1-9a00a96b7078">
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_212e8f5c-2731-4cad-b423-3e92c83c553b">
                                <emphasis role="bold">Units</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_34d246e9-86c0-4755-bfe5-b8be525da423">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ce2fee3-4908-43d0-aab4-4fa7f3b5edaa">
                                <link linkend="DCM_113043" xrefstyle="select: nopage">113043</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2b5fc8eb-8caf-4c8a-b15f-a4afe7ce6fa1">Diffusion weighted</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2b5f7dbf-a778-4899-bf6a-b01c56a01329"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_07c1a6f1-ccb1-472f-9a0e-2b0523d1c1a8"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a228f0d2-c420-4fd3-98ea-9014c19789e9">DT (1, UCUM, "no units")</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6495b6a2-1276-4d71-8edf-719695ed7d59">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b503289d-ad31-42ef-87dc-f5129968c3a9">
                                <link linkend="DCM_110810" xrefstyle="select: nopage">110810</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_97e9ca79-03bf-43f0-bd61-d2c148ac997d">Volumetric Diffusion Dxx Component</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7112f1f0-b379-4769-807b-d450f10a2d52"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0eff420f-33ef-4155-9720-2d09612932f4"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0905daa7-b55f-4243-af95-76910ef64728">DT (1, UCUM, "no units")</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c50d76a9-c852-476a-b504-395fa9fe697d">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_28e9b321-60fc-46af-9adb-85f891fd5c97">
                                <link linkend="DCM_110811" xrefstyle="select: nopage">110811</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c3a8fb22-75ca-4e8f-8d23-e80c9b5c1ef2">Volumetric Diffusion Dxy Component</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4645028f-df72-45e7-8048-eb138262fcef"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_18ed8b27-848c-498f-8209-6f561fb5e992"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_130fff62-88be-4ee1-ae00-6c59d82851d3">DT (1, UCUM, "no units")</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6cacdfc4-2c11-4393-b280-33f456ac2287">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e69374b1-553f-4025-93d0-ba0c41791efc">
                                <link linkend="DCM_110812" xrefstyle="select: nopage">110812</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_47451c6d-5516-4ef7-b6ec-5543d390c1e6">Volumetric Diffusion Dxz Component</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a0ca8c6-b155-402c-bcee-ee118ea00757"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ee0a838-be42-4809-bfc5-f6e15a85bb80"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_954c9174-ffe7-43ac-a8c8-717f82324ee2">DT (1, UCUM, "no units")</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eea964b7-eba8-4f2a-b395-e21f11f7ae9b">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_029aceef-a490-4ec7-af43-fd9cb1da901c">
                                <link linkend="DCM_110813" xrefstyle="select: nopage">110813</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2552feb2-c60b-4e2b-bb6f-af86b609d894">Volumetric Diffusion Dyy Component</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8fbc0cc-4cb2-4ebb-b4ee-4c632a737367"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a4ff80e7-47a0-4bf5-8968-2b4864f5e442"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_21aa51ad-2a70-4024-bdbd-d638664f2f1e">DT (1, UCUM, "no units")</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58c17c61-464a-4121-83f7-a1ba30f42235">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d73c5b3-d10c-40e1-841e-6d325c4840f5">
                                <link linkend="DCM_110814" xrefstyle="select: nopage">110814</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b6e82e76-5987-4fb4-be4e-3d9f0072dd19">Volumetric Diffusion Dyz Component</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_be319379-178d-4c08-bf5c-433deae0635d"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87f62aaa-b789-49d3-bc41-4c62f0a00531"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d73f74b3-94a6-4de0-bb39-10ff6e5ee291">DT (1, UCUM, "no units")</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2b01bdef-bfc0-4ecf-911b-cb42b5a570bf">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82c8a097-1113-4bc1-80f7-adfe80b8797c">
                                <link linkend="DCM_110815" xrefstyle="select: nopage">110815</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_01756ade-d07f-4c68-90f5-a7a7a3215560">Volumetric Diffusion Dzz Component</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ed7d38db-0817-4094-9371-f8c8695303b8"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0edf7f0f-aed2-4966-84b3-b2dcc0dde90c"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_eba12d29-ff7e-4a77-965f-700b188fe092">DT (1, UCUM, "no units")</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 7271" status="3" xml:id="sect_CID_7271">
            <title>MR Diffusion Anisotropy Indices</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ceb89830-b51d-4c04-b5e4-d11a0b3653f5">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7271.html" xl:show="new">HTML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7271.json" xl:show="new">FHIR JSON</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7271.xml" xl:show="new">FHIR XML</link>
                                | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1166.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_b764a4d4-b1b5-4ca0-b386-57316fce0cdd">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_82517b22-6130-4b86-854f-59faa6f8b9f3">
                            <emphasis role="bold">20170413</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_676f3eb5-3652-4eec-a07e-4c0d6eef1371">
                            <emphasis role="bold">1.2.840.10008.6.1.1166</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7271" rules="all" xml:id="table_CID_7271">
                <caption>MR Diffusion Anisotropy Indices</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de451b7d-d38f-4899-afda-705483b384f7">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_026b9ecd-9268-4a89-8343-b2181448c15e">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8dbd56ba-8c5a-4e93-9933-bb923d74dc8a">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9662a0b-213e-4396-9487-d58e40f7bc6d">
                                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12dbe512-9b31-4365-a74a-129ff3a87f1d">
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_416fc904-5e5f-4a83-90f1-ae25ba50aa4a">
                                <emphasis role="bold">Units</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5e05f73-37a7-4676-957d-384ae0353f46">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a2352182-528c-4ccc-aa24-2da1af18415e">
                                <link linkend="DCM_110808" xrefstyle="select: nopage">110808</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d83e1d4c-c05a-4386-b2be-eb507229b3b8">Fractional Anisotropy</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d5299ff8-e1e9-43b0-a909-6fec6d276d70"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_253fa913-f1d2-404a-807b-a1a3fcee76a0"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e92ca842-7de9-451c-b36d-add18e7e5ef3">DT ({0:1}, UCUM, "range 0:1")</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9043d7e6-9705-490a-91d5-4a28c0957e47">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b2952ac7-8c24-41db-a043-b8f61c150e4d">
                                <link linkend="DCM_110809" xrefstyle="select: nopage">110809</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ed6c4926-214a-4296-8966-1d87c0072fee">Relative Anisotropy</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb2ec4b1-12e2-4044-ab64-28abfa6ab3f7"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f666a8c2-2ec1-4f52-ab4f-d07c6672ecc5"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_186faeab-a9fa-4b4b-909a-395971df9fec">DT ({ratio}, UCUM, "ratio")</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c2d6e00-f2b5-4e6d-930d-c6ff4573782d">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0931a89-921a-4d4b-a5ed-ff1c9604cbf1">
                                <link linkend="DCM_113288" xrefstyle="select: nopage">113288</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_be73c794-88cf-49a4-8b7b-36016965295a">Volume Ratio</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_17f62f96-3ffb-4c66-80ce-5d69b3e6a066"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7414b1bd-5da9-49ec-b0ba-9f5ef54f7cac"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e375845c-60f8-4828-bad5-96b8040e49e3">DT ({0:1}, UCUM, "range 0:1")</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 7272" status="3" xml:id="sect_CID_7272">
         <title>MR Diffusion Model Parameters</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_1ad02b35-e9da-4e21-8b76-df218d37875d">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7272.html" xl:show="new">HTML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7272.json" xl:show="new">FHIR JSON</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7272.xml" xl:show="new">FHIR XML</link>
                        | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1167.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_c5d70e23-d99f-4e15-8066-544fde5d2303">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_e6d09219-701b-4856-8b4b-6c148b5f4599">
                     <emphasis role="bold">20170413</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_6a831c3f-0bb7-49f2-a802-9010f679e2d7">
                     <emphasis role="bold">1.2.840.10008.6.1.1167</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 7272" rules="all" xml:id="table_CID_7272">
            <caption>MR Diffusion Model Parameters</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9eeb1a9c-c653-4dca-bcf0-b72023f09abc">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d700a266-ca72-4a78-864f-2f66ae04b170">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6b8068b0-f327-4ab7-b907-5d773c2efc3f">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_00101fe5-b78e-4f04-aaa2-2bfa4edef873">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7aadd19e-6774-4b40-913d-ef55017ee4fe">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5f9ae5d7-9808-4bfb-b405-bffbafa8ecbc">
                        <emphasis role="bold">Units</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f027dcc1-66a2-41b1-87b5-65fc79fc2e9c">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d588730b-1c0d-42cb-91f3-edac626c7585">
                        <link linkend="DCM_113041" xrefstyle="select: nopage">113041</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0804425a-af69-4718-a2bf-1825f3f16adf">Apparent Diffusion Coefficient</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d9d7ea7b-0a01-4d0c-9dcc-5509ed146af9"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_67891df1-7e2b-4651-a036-72e05f0763dc">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C3890194" xl:show="new">C3890194</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6146eb94-9fba-4acf-86f5-0dd921fce5b4">D<xref linkend="sect_CID_7277" xrefstyle="select: labelnumber quotedtitle"/>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f2e6c013-2ca1-4318-a47a-a78a54431181">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_50d5c961-8612-4106-9357-53735465c493">
                        <link linkend="DCM_113289" xrefstyle="select: nopage">113289</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b4009c14-8996-4a9a-98c1-54529a408126">Diffusion Coefficient</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_15507c74-aa93-4ee3-b5ee-147a21aff001"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f94affce-6dc1-4924-9479-f31233b25702"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_daad94c3-ccc7-4ed4-8547-12f6021c3ecc">D<xref linkend="sect_CID_7277" xrefstyle="select: labelnumber quotedtitle"/>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8b6463db-8b5e-41e7-b7b1-f2a3741b7f25">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_db7f0b50-5c86-42e2-a59b-c6236d34c267">
                        <link linkend="DCM_113290" xrefstyle="select: nopage">113290</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a3ddcccf-16f7-4b17-a535-a05a62ccc0a9">Mono-exponential Apparent Diffusion Coefficient</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ead3ed6a-5878-491d-b087-e6e35abc6d4c"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fdb1809f-0af3-4fc0-a236-2a2556fe1b1b"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_2890e0af-5b9e-473d-8b68-c9e429d73c89">D<xref linkend="sect_CID_7277" xrefstyle="select: labelnumber quotedtitle"/>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ba9668b2-5c30-4c51-afd8-1355dec27e3b">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fab6ee8c-499b-4784-a601-e025528b8bbb">
                        <link linkend="DCM_113291" xrefstyle="select: nopage">113291</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7ca141fd-27b0-49ce-9b24-3ad6d8fc746e">Slow Diffusion Coefficient</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cb1e83bb-5e2c-4399-9970-70da792648d0"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_34cee3a8-ca8a-4ee1-82cf-83a9efed6f19"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_10e315c3-661c-4a1f-a0ca-02ae86f48b82">D<xref linkend="sect_CID_7277" xrefstyle="select: labelnumber quotedtitle"/>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bb1681c2-e660-46e3-ae0d-706d313ad540">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_726beab4-1f56-4a75-be49-8b38783322f9">
                        <link linkend="DCM_113292" xrefstyle="select: nopage">113292</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0c81f610-93be-489f-9774-4e1d868dd6c5">Fast Diffusion Coefficient</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7bf59ac7-d77b-4892-bc77-c60b31dce88f"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7598e287-5ec6-4446-97e0-8add4806b800"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_45981176-d812-4388-b449-bf62eec3646d">D<xref linkend="sect_CID_7277" xrefstyle="select: labelnumber quotedtitle"/>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b5ec1c74-eefd-4a43-9552-64e54f6b1be4">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_618913fc-0f8a-41ef-9d23-b3ecfd2387f5">
                        <link linkend="DCM_113293" xrefstyle="select: nopage">113293</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d5f217b1-7dd3-4759-b616-fbab398489b0">Fast Diffusion Coefficient Fraction</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_412ef0ff-463e-4d4a-bf92-e75c70c9b439"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_65c5fef8-9b5c-4cf4-8844-6cbb2025b4b4"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5c84ab4c-e48e-4fed-b687-c4c9eca89512">DT ({0:1}, UCUM, "range 0:1")</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8886179a-4c82-44f1-a0c5-5bea649316b7">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7471bfdb-1a9e-4076-bef0-f5ab5295afa0">
                        <link linkend="DCM_113294" xrefstyle="select: nopage">113294</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3b0f8d8c-c7c9-4582-b294-ffd715f55e45">Kurtosis Diffusion Coefficient</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_325eb7b4-2257-4323-835a-1866e2699eb3"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_78c6c9b6-2903-46c5-b8a2-03cefc2b565f"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_67d02704-1758-4973-93f7-74a9795b64c4">D<xref linkend="sect_CID_7277" xrefstyle="select: labelnumber quotedtitle"/>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_56d7d22d-3c04-4165-b323-58cba5275ee9">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c5f0721c-84a6-431b-8be6-31058c742a65">
                        <link linkend="DCM_113295" xrefstyle="select: nopage">113295</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9262b1af-945b-413a-b9f5-3e2ffc6a461f">Gamma Distribution Scale Parameter</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_42819291-952e-4093-a2fa-0cb69df135fa"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3782f6a5-9657-4f0a-8f87-4eeebc75aedb"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a6b9cccf-53e9-4cad-83d2-25b578d647d2">DT (1, UCUM, "no units")</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_db481ce6-9f10-44eb-9cf9-1eaf5cd009ee">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a33264e3-4c70-4f3d-a6b4-b4d088c6185c">
                        <link linkend="DCM_113296" xrefstyle="select: nopage">113296</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8ab1157b-483e-4bd4-9014-f7f6757ff9d2">Gamma Distribution Shape Parameter</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5ed2443f-79b1-412f-8518-36a4d3c93ae3"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4b970ebc-e46c-4655-a5f9-df470f6f52ea"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_54fec7f6-a8e5-4b89-8d2a-5a08078e39a3">DT (1, UCUM, "no units")</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_27c04e9a-3c4f-4989-9413-5dea4a07f853">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dd069205-45bc-4d4e-9f3a-b48bff49fe76">
                        <link linkend="DCM_113297" xrefstyle="select: nopage">113297</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a2121d04-9234-4d0e-b5e8-7ef1460b4143">Gamma Distribution Mode</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bea55b72-09c7-43b6-8bb1-8949cf651b37"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fc70443c-dcd7-4a98-b765-be4b4036f221"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fd84c9f1-c717-40bf-b766-a6dbe7d7e534">DT (1, UCUM, "no units")</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b7883475-a298-47e4-8220-12d279f9525e">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4a3c4556-4532-4740-a851-422f1bdf19c1">
                        <link linkend="DCM_113298" xrefstyle="select: nopage">113298</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1187a08e-f319-4189-a430-b9f55ba79c21">Distributed Diffusion Coefficient</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_19944210-2b86-4690-99cf-6c42874b0ced"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1c692431-b442-475a-9912-da5994ad342b"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4f73104e-e3de-4aa2-b343-63cc0c9b698b">D<xref linkend="sect_CID_7277" xrefstyle="select: labelnumber quotedtitle"/>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0137b33c-16c5-43fa-a2db-1413b4831bf8">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b8e76f43-7abf-4c61-b624-ec47c0339562">
                        <link linkend="DCM_113299" xrefstyle="select: nopage">113299</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_85f42bd8-6a9f-4106-ba55-a95cca092244">Anomalous Exponent Parameter</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2a93777e-77e5-469b-9279-d530466e3a1d"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_af291701-985a-4e1c-b1b5-2c89b5b52575"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7f4e9511-7321-4e51-84c6-f05cd944f2c7">DT ({0:1}, UCUM, "range 0:1")</para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
       
       <section label="CID 7277" status="3" xml:id="sect_CID_7277">
          <title>Units of Diffusion Rate Area Over Time</title>
          <variablelist spacing="compact">
             <varlistentry>
                <term>
                   <emphasis role="bold">Resources:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_67cb8fb2-c091-4736-a4a4-08684db1afb3">
                      <emphasis role="bold">
                         <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7277.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7277.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7277.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1172.xml" xl:show="new">IHE SVS XML</link>
                      </emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">Type:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_5f99a8a8-f237-44f7-9be5-e3e7d5018f30">
                      <emphasis role="bold">Extensible</emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">Version:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_e56a67db-a89b-4744-bce8-e36826ac3855">
                      <emphasis role="bold">20170413</emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">UID:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_4f43bed5-98a3-4f64-87c9-d42f8c99d998">
                      <emphasis role="bold">1.2.840.10008.6.1.1172</emphasis>
                   </para>
                </listitem>
             </varlistentry>
          </variablelist>
          <table frame="box" label="CID 7277" rules="all" xml:id="table_CID_7277">
             <caption>Units of Diffusion Rate Area Over Time</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_a12d784f-8806-415a-a63a-bdcdd38784c7">
                         <emphasis role="bold">Coding Scheme Designator</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_690d569b-78bd-4b5f-9c1b-67e85383a940">
                         <emphasis role="bold">Code Value</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_7e8c95d3-252a-4e7f-bc75-7866c7a1adb3">
                         <emphasis role="bold">Code Meaning</emphasis>
                      </para>
                   </th>
                </tr>
             </thead>
             <tbody>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_e723fb7b-6746-4428-85c2-36e83ad0a7e1">UCUM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_67407a7e-4ca0-4c44-93b0-cc51fe7691fa">mm2/s</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_d3140409-38eb-4206-91fb-a835174574de">mm2/s</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_3c81d9ae-5df5-4e8b-982f-8cfdd63c704f">UCUM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_87479311-7e81-427b-add5-67369f81d660">um2/ms</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_c5c891f2-ccc8-4ccf-93a7-761e409720cc">um2/ms</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_3b43ec8d-346f-430f-94ec-e65b8c427874">UCUM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_444c5bed-9dc1-4a4d-8bb1-8f88915322df">um2/s</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_3caee25a-4d17-44be-bdde-1e3c8fb43245">um2/s</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_89d66864-c6f0-482a-9dec-bc9472fd5e90">UCUM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_75b28d05-4435-49dd-b850-9fc359279034">10-6.mm2/s</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_eed6e44a-2a7d-4fd1-92ec-67758fdfb276">10-6.mm2/s</para>
                   </td>
                </tr>
             </tbody>
          </table>
          <note>
             <para xml:id="para_3c40e41e-bfbd-473a-a781-28cce3d85839"/>
          </note>
       </section>

       <section label="D" status="1" xml:id="chapter_D">
          <title>DICOM Controlled Terminology Definitions (Normative)</title>
          <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
             <caption>DICOM Controlled Terminology Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">
                         <emphasis role="bold">Code Value</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">
                         <emphasis role="bold">Code Meaning</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">
                         <emphasis role="bold">Definition</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">
                         <emphasis role="bold">Notes</emphasis>
                      </para>
                   </th>
                </tr>
             </thead>
             <tbody>
               <tr>
                  <td align="center" colspan="1"/>
                  <td align="left" colspan="1"/>
                  <td align="left" colspan="1"/>
                  <td align="left" colspan="1"/>
               </tr>
                
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_121216">121216</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_73209cec-d884-4729-b49e-16f794149675">Volume estimated from single 2D region</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_eea650b9-326f-497a-a5fd-5136eff01ef4">A three-dimensional numeric measurement that is approximate, based on a two-dimensional region in a single image.</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_67d34b8a-2f8c-4bbb-a743-7c91f3270258"/>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_121217">121217</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_d55e67ec-e2c8-4e1d-9855-ecca30df013f">Volume estimated from three or more non-coplanar 2D regions</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_ee4f453c-a7f0-42a5-ac1b-6225d5e15fb8">A three-dimensional numeric measurement that is approximate, based on three or more non-coplanar two-dimensional image regions.</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_7c397f6c-41d9-4b00-82de-36fb0a3c2343"/>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_121218">121218</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_abf603e3-dc37-470f-a7ab-51a185df165a">Volume estimated from two non-coplanar 2D regions</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_c46a13bb-bf91-4c1a-b00c-86de9aefc28c">A three-dimensional numeric measurement that is approximate, based on two non-coplanar two-dimensional image regions.</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_497905cf-0e45-4288-9a03-2f53d3d14345"/>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_121219">121219</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_705bd6e4-cdf8-4443-8e38-3f12f015138a">Volume of bounding three dimensional region</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_12914f1d-9369-4fe2-8740-5ecc6b339278">A three-dimensional numeric measurement of the bounding region of a three-dimensional region of interest in an image set.</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_f27d6dde-b2de-46f9-a03f-d61e91a974d8"/>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_121220">121220</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_2c1da797-f29c-4b92-9aab-2464ec162772">Volume of circumscribed sphere</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_e69fd1df-db07-4ca8-b7f2-dfa444b759dd">A three-dimensional numeric measurement of the bounding sphere of a three-dimensional region of interest in an image set.</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_6a675095-7d6b-407b-b87d-00f53cb52b5d"/>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_121221">121221</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_6d83346a-af55-4d74-9826-71757c8a2874">Volume of ellipsoid</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_1beff467-c0b3-4eda-8b44-e6bce885c6b1">A three-dimensional numeric measurement of an ellipsoid shaped three-dimensional region of interest in an image set.</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_e650a405-4666-4fa1-8c5b-cb8a547f5e34"/>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_121222">121222</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_ecf18a46-ec1f-4513-b1f5-f39ce69838a6">Volume of sphere</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_6a9fbf27-8b80-43e4-b293-591569b04701">A three-dimensional numeric measurement of a sphere shaped three-dimensional region of interest in an image set.</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_4b6e0d66-b127-4d5e-8e70-ee0585c10cd6"/>
                   </td>
                </tr>
                
                <tr>
                   <td align="center" colspan="1"/>
                   <td align="left" colspan="1"/>
                   <td align="left" colspan="1"/>
                   <td align="left" colspan="1"/>
                </tr>
                
                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126050">126050</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_82a8b177-a776-4ebb-a3be-2ca98d7a774e">Fractal Dimension</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_1faf3b63-fafc-4a9a-ad88-8d4c4e526824">A statistical index of complexity comparing how detail in a fractal pattern changes with the scale at which it is measured; a ratio of the change in detail to the change in scale.</para>
                   </td>
                   <td align="left" colspan="1"/>
                </tr>
                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126051">126051</para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_8a23d651-e98f-47ec-9f8c-7340418d7d3c">Skewness</para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_27ddcc2b-0665-4ceb-84da-abf1853ae12a">Measure of the asymmetry of the probability distribution of a real-valued random variable about its mean.</para>
                   </td>
                   <td align="left" colspan="1"/>
                </tr>
                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126052">126052</para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_4dd51832-aed0-4560-9437-44c7ce4c7817">Kurtosis</para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_05a8df0d-9065-4364-b8d1-18a93c8830fd">Measure of the peakedness of the probability distribution of a real-valued random variable.</para>
                   </td>
                   <td align="left" colspan="1"/>
                </tr>
                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126060"><emphasis role="italic">126060</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_36c29347-422c-44db-a4c2-801f855615f4"><emphasis role="italic">Joint Entropy of GLCM</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_79ddffa9-a3f3-40e6-b7ab-68c32cab6250"><emphasis role="italic">The zero order entropy of a Gray Level Co-occurrence Matrix (GLCM). A measure of disorder. Abbreviated ENT.</emphasis></para>
                      <para xml:id="para_2ff5f3fa-1f9e-4793-9ebd-4a77136fc456"><emphasis role="italic">See F<subscript>cm.joint.entr</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                  <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis>
                            </para>
                  <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.4.0, IBSI, "Joint Entropy of GLCM")</emphasis></emphasis></emphasis>
                            </para>
               </td>
                </tr>
                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126061">126061</para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_c631328c-5e78-4395-9607-040cf184f180">Root Angular Second Moment of GLCM</para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_8de41f82-bd2e-4e42-9ce0-1a7e2535d64d">The square root of the Angular Second Moment (ASM) of a Gray Level Co-occurrence Matrix (GLCM). A measure of orderliness.</para>
                      <para xml:id="para_69f50963-8921-4bc0-83e9-328bcfb3e286">See <link xl:href="http://www.fp.ucalgary.ca/mhallbey/equations.htm"/>.</para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_fdccefd6-7ff0-4a39-8a85-c62ad051626d">Sometimes referred to as "energy", "uniformity" or "uniformity of energy" but then potentially confused with ASM. Not defined in <xref linkend="biblio_IBSI_Features"/>
                      </para>
                   </td>
                </tr>
                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126062"><emphasis role="italic">126062</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_270d5893-991e-47ec-96e5-d5b0b804eb6d"><emphasis role="italic">Inverse Difference Moment of GLCM</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_3ca85ace-c55a-4de1-ae72-0f51dab7e8dd"><emphasis role="italic">The Inverse Difference Moment (homogeneity) of a Gray Level Co-occurrence Matrix (GLCM). Abbreviated IDM.</emphasis></para>
                      <para xml:id="para_092daca8-866b-47a3-a816-c1f35674f005"><emphasis role="italic">See F<subscript>cm.inv.diff.mom</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_7291510e-eec3-45c3-82b6-bf9e8060e3e5"><emphasis role="italic">Other concepts are sometimes referred to as "homogeneity", e.g., the "inverse difference", which is calculated from the absolute value of differences rather than square of them.</emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.16.0, IBSI, "Inverse Difference Moment of GLCM")</emphasis></emphasis></emphasis></para>
                                      </td>
                </tr>
                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126063"><emphasis role="italic">126063</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_53e7905c-42b5-4ad9-bc3a-d58db16ce500"><emphasis role="italic">Contrast of GLCM</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_9dde55fd-eacd-4648-98dc-bb1480c79962"><emphasis role="italic">The sum of squares of a Gray Level Co-occurrence Matrix (GLCM). A measure of gray level variations. Abbreviated CON.</emphasis></para>
                      <para xml:id="para_3fd341de-f682-40c4-ad31-62fef52eb8fe"><emphasis role="italic">See F<subscript>cm.contrast</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_2839759b-dfad-41b1-9600-7e940a8f11ac"><emphasis role="italic">Distinct from "joint (sum of squares) variance" and "dissimilarity".</emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.12.0, IBSI, "Contrast of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>
                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126064"><emphasis role="italic">126064</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_af26a1f5-4c60-44f9-acf3-47f7b55ae248"><emphasis role="italic">Dissimilarity of GLCM</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_a6a66989-dce5-4dd7-ad15-19d2431e400e"><emphasis role="italic">The dissimilarity of a Gray Level Co-occurrence Matrix (GLCM). Abbreviated DIS.</emphasis></para>
                      <para xml:id="para_f939bdf5-3373-4037-8126-5e5deca720af"><emphasis role="italic">See F<subscript>cm.dissimilarity</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_afead18b-048f-43ff-a7ac-e4bf513d00da"><emphasis role="italic">Distinct from "contrast", which uses square rather than absolute value of difference.</emphasis></para>
                                          <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.13.0, IBSI, "Dissimilarity of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126065"><emphasis role="italic">126065</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_cf0eaa3f-3ff4-4fe3-aee5-6dd315c5696f"><emphasis role="italic">Angular Second Moment of GLCM</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_4509dbfa-bf13-4b31-b8ea-eb00fd15b5df"><emphasis role="italic">The Angular Second Moment of a Gray Level Co-occurrence Matrix (GLCM). Abbreviated ASM.</emphasis></para>
                      <para xml:id="para_e3cf1c80-d4cc-4bf3-801c-c5ba201fd1c2"><emphasis role="italic">See F<subscript>cm.energy</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_36cc3678-488d-4287-b04c-e3e8e9f4d616"><emphasis role="italic">Sometimes referred to as "energy", "uniformity" or "uniformity of energy" but then potentially confused with square root of ASM.</emphasis></para>
                                          <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.11.0, IBSI, "Angular Second Moment of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126066"><emphasis role="italic">126066</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_9e7cef00-6579-4c23-91c6-c76859837294"><emphasis role="italic">Correlation of GLCM</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_48f4c2aa-a9d6-409e-b61e-e0ee5933d1e7"><emphasis role="italic">A measure of the linear dependency of gray levels on those of neighbouring pixels of a Gray Level Co-occurrence Matrix (GLCM). Abbreviated COR.</emphasis></para>
                      <para xml:id="para_aac63cc2-fb0c-40ae-90ba-6b51a78430f7"><emphasis role="italic">See F<subscript>cm.corr</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_e3843cac-caeb-4b5e-8041-489088185c59"><emphasis role="italic">Correlation is NaN for a constant image.</emphasis></para>
                                          <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.19.0, IBSI, "Correlation of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126067">126067</para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_29b741b2-c77b-4e88-8f71-e816d0a7d47c">Gray Level Co-occurrence Matrix</para>
                   </td>
                   <td align="left" colspan="1">
                      <para xml:id="para_5abe135c-ad0c-4502-a1b4-110550d109df">A tabulation of how often different combinations of pixel values (gray levels) occur in an image. Abbreviated GLCM.</para>
                      <para xml:id="para_1532bbb9-943a-45a7-b228-bfb9e12c0e06">See <xref linkend="biblio_IBSI_Features"/>.</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1"/>
                </tr>
               <tr>
                  <td align="center" colspan="1"/>
                  <td align="left" colspan="1"/>
                  <td align="left" colspan="1"/>
                  <td align="left" colspan="1"/>
               </tr>      <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128776">128776</para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_a6dcc524-bada-4dac-8ad2-1b12b6a6e494">Gray Level Run Length Matrix</para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_09dd1daa-f6e9-48a4-8e08-5c179d67bb59">The tabulation of gray level run lengths in a particular direction in an image. Abbreviated GLRLM.</para>
                  <para xml:id="para_f40b9cc5-51e6-4a80-9054-2b146a1a4e27">See <xref linkend="biblio_IBSI_Features"/>.</para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_78887456-b0f5-4fb2-b4ba-19e4556443d1"/>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128777">128777</para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_019526f2-a4a7-4a66-8648-a9921aa45dba">Gray Level Size Zone Matrix</para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_5166df07-59a0-4d8b-83c6-9e08e5ab81ea">A tabulation of counts of the number of groups of connected voxels with a specific discretized gray level value and size. Abbreviated GLSZM.</para>
                  <para xml:id="para_3a1bf359-501b-40e4-9312-399875749fe2">See <xref linkend="biblio_IBSI_Features"/>.</para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_6ffea550-e3b6-4603-bea0-c16ea34a6a4d"/>
                   </td>
                </tr>
                 
                 <tr>
                     <td align="center" colspan="1" rowspan="1">
                         <para xml:id="DCM_ddd400"><emphasis role="bold"><emphasis role="underline">ddd400</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">Gray Level Distance Zone Matrix</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">A tabulation of counts of the number of groups (or zones) of linked voxels that share a specific discretised grey level value and possess the same distance to ROI edge. Abbreviated GLDZM.</emphasis></emphasis></para>
                         <para><emphasis role="bold"><emphasis role="underline">See <xref linkend="biblio_IBSI_Features"/>.</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1">
                         <para/>
                     </td>
                 </tr>
                 <tr>
                     <td align="center" colspan="1" rowspan="1">
                         <para xml:id="DCM_ddd401"><emphasis role="bold"><emphasis role="underline">ddd401</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">Neighbourhood Grey Tone Difference Matrix</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">A matrix containing the sum of grey level differences of pixels/voxels with a discretised grey level and average discretised grey level of neighbouring pixels/voxels within a specified Chebyshev distance. Abbreviated NGTDM.</emphasis></emphasis></para>
                         <para><emphasis role="bold"><emphasis role="underline">See <xref linkend="biblio_IBSI_Features"/>.</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1">
                         <para/>
                     </td>
                 </tr>
                 <tr>
                     <td align="center" colspan="1" rowspan="1">
                         <para xml:id="DCM_ddd402"><emphasis role="bold"><emphasis role="underline">ddd402</emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1"><emphasis role="bold"><emphasis role="underline">
                                    <para>Neighbouring Grey Level Dependence Matrix</para>
                                </emphasis></emphasis></td>
                     <td align="left" colspan="1">
                         <para><emphasis role="bold"><emphasis role="underline">A tabulation of the counts of dependent (within a specified coarseness parameter) neighbouring discretised grey levels within a specified Chebyshev distance. Abbreviated NGLDM.</emphasis></emphasis></para>
                         <para><emphasis role="bold"><emphasis role="underline"><emphasis role="italic">See <xref linkend="biblio_IBSI_Features"/>.</emphasis></emphasis></emphasis></para>
                     </td>
                     <td align="left" colspan="1">
                         <para/>
                     </td>
                 </tr>



            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128781"><emphasis role="italic">128781</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_afe10b24-a5f6-4edb-89b5-a9a6101310db"><emphasis role="italic">Joint Maximum of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_b2302182-8614-4255-b1e3-d9789f2355b8"><emphasis role="italic">The probability corresponding to the most common gray level co-occurrence in the GLCM. Abbreviated MAX.</emphasis></para>
                  <para xml:id="para_641583b2-c161-40ca-942d-bee0e20097af"><emphasis role="italic">See F<subscript>cm.joint.max</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.1.0, IBSI, "Joint Maximum of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128782"><emphasis role="italic">128782</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_04c390eb-7eac-4f38-9409-5323a77c3319"><emphasis role="italic">Joint Average of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_84c98372-1479-4732-996f-7ce4df3529dd"><emphasis role="italic">The gray level weighted sum of joint probabilities of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_42145814-d6dc-4e46-9d0c-f4bb00c1ee45"><emphasis role="italic">See F<subscript>cm.joint.avg</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.2.0, IBSI, "Joint Average of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128783"><emphasis role="italic">128783</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_91aa967a-1c0a-4efc-b29d-d7d196236339"><emphasis role="italic">Joint Variance of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_df58da02-2f84-4827-8602-db2aec7d9c00"><emphasis role="italic">The sum of squares of the difference from the joint average of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_2137ac20-ada8-4941-a9e0-86e5a9936372"><emphasis role="italic">See F<subscript>cm.joint.var</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.3.0, IBSI, "Joint Variance of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128784"><emphasis role="italic">128784</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_25c348a4-1d48-46fb-83f7-88d6d1622107"><emphasis role="italic">Difference Average of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_20585b2d-fd71-4f47-ac2b-015f58486770"><emphasis role="italic">The average for the diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_c8334c15-a7b0-47bd-b1f0-82bcecb488b0"><emphasis role="italic">See F<subscript>cm.diff.avg</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.5.0, IBSI, "Difference Average of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128785"><emphasis role="italic">128785</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_ba523365-5f7a-4a84-8780-e58a0466b01c"><emphasis role="italic">Difference Variance of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_6e56b77a-7ee5-4015-b03f-1df2276ecd83"><emphasis role="italic">The variance for the diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_48da24e5-4d37-40b1-b7db-f3ec4b26b994"><emphasis role="italic">See F<subscript>cm.diff.var</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.6.0, IBSI, "Difference Variance of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128786"><emphasis role="italic">128786</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_36ffa4c5-7f09-482e-b2fe-060d1d3184ff"><emphasis role="italic">Difference Entropy of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_f4dd9a56-70ed-40ce-96e1-b3400f979a9f"><emphasis role="italic">The entropy for the diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_8896d006-eb20-4de8-90d2-597bb17f783c"><emphasis role="italic">See F<subscript>cm.diff.entr</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.7.0, IBSI, "Difference Entropy of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128787"><emphasis role="italic">128787</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_feea8975-17ad-4106-ab3e-3b2244ef858d"><emphasis role="italic">Sum Average of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_1acbe7f1-4013-4972-b026-9e55698ab149"><emphasis role="italic">The average for the cross-diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_480724bb-2d46-4e62-87ba-979db124c219"><emphasis role="italic">See F<subscript>cm.sum.avg</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.8.0, IBSI, "Sum Average of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128788"><emphasis role="italic">128788</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_8fd99260-8a4f-4776-ad25-c8958f4e0b71"><emphasis role="italic">Sum Variance of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_92860fd5-d1b8-42e9-8fdc-0b95ef4253a3"><emphasis role="italic">The variance for the cross-diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_edc8918c-7387-475a-9edf-f370b8cc3987"><emphasis role="italic">See F<subscript>cm.sum.var</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.9.0, IBSI, "Sum Variance of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128789"><emphasis role="italic">128789</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_d7172dfb-5af4-48a2-a538-6fc53b633b0c"><emphasis role="italic">Sum Entropy of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_c1f907fd-8a8f-4447-a108-482dad54fa81"><emphasis role="italic">The entropy for the cross-diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_0f8d207b-b15b-4947-b707-37d8958cd85c"><emphasis role="italic">See F<subscript>cm.sum.entr</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.10.0, IBSI, "Sum Entropy of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128790"><emphasis role="italic">128790</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_8854b44f-2a53-4575-b8de-0776d278fb3f"><emphasis role="italic">Inverse Difference of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_55548cc9-32d4-4832-b389-da9016ef4f13"><emphasis role="italic">The inverse difference of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_8f06e191-4090-4e1e-acca-a0934fae9aa3"><emphasis role="italic">See F<subscript>cm.inv.diff</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_bd762ee6-9b94-4abf-be86-67873376dae4"><emphasis role="italic">Sometimes referred to as "homogeneity" but that term is historically used to refer to the "inverse difference moment", which is calculated from the square of differences rather than absolute value of them.</emphasis></para>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.14.0, IBSI, "Inverse Difference of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128791"><emphasis role="italic">128791</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_452eea19-e357-492e-973e-067043df7738"><emphasis role="italic">Inverse Difference Normalized of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_1ce1071e-1f3f-46ae-8f08-e9b6c8db6743"><emphasis role="italic">The normalized inverse difference of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_e3a46d25-0d26-4d1f-b7c2-a0d2c4c298aa"><emphasis role="italic">See F<subscript>cm.inv.diff.norm</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_056810d1-2fff-4e37-aa5f-570f641ec19f"><emphasis role="italic">The US not UK spelling of "normalized" is used to be consistent with the DICOM convention, rather than the IBSI spelling.</emphasis></para>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.15.0, IBSI, "Normalized Inverse Difference of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128792"><emphasis role="italic">128792</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_ee984185-f22c-42a1-b01d-c47a7a9f3266"><emphasis role="italic">Inverse Difference Moment Normalized of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_5a5758fc-312e-4eb2-a1eb-49fc8631bc6f"><emphasis role="italic">The normalized inverse difference moment of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_277401df-7ab7-40bc-84e0-1ec8600e1408"><emphasis role="italic">See F<subscript>cm.inv.diff.mom.norm</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_917a8d59-e8aa-4205-8529-f617b17f5926"><emphasis role="italic">The US not UK spelling of "normalized" is used to be consistent with the DICOM convention, rather than the IBSI spelling.</emphasis></para>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.17.0, IBSI, "Normalized Inverse Difference Moment of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128793"><emphasis role="italic">128793</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_457dfcf2-29ff-4788-89f0-f5b600f1f3f9"><emphasis role="italic">Inverse Variance of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_4b79277e-001d-4293-8023-7c79a51bedcb"><emphasis role="italic">The inverse variance of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_fd71c316-bd50-4bc8-aed3-9b6f3815280f"><emphasis role="italic">See F<subscript>cm.inv.var</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.18.0, IBSI, "Inverse Variance of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128794"><emphasis role="italic">128794</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_72155589-37fb-4aee-818d-f2976ba6b753"><emphasis role="italic">Autocorrelation of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_d216f9f8-0320-46bf-81fc-4307a970605e"><emphasis role="italic">The autocorrelation of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_68acdf7f-7513-4389-90fc-0ff30a601be0"><emphasis role="italic">See F<subscript>cm.auto.corr</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.20.0, IBSI, "Autocorrelation of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128795"><emphasis role="italic">128795</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_eee7c6ef-73b2-474d-b438-357993d39410"><emphasis role="italic">Cluster Tendency of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_78b175d4-2f39-4a1c-8912-2cfca528b1c2"><emphasis role="italic">The cluster tendency of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_a07fb140-1d06-46f7-b984-f72b417f5012"><emphasis role="italic">See F<subscript>cm.clust.tend</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.21.0, IBSI, "Cluster Tendency of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128796"><emphasis role="italic">128796</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_2f831be7-5ce1-4850-9c35-412d2fcb7de1"><emphasis role="italic">Cluster Shade of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_aad685f9-515e-42e8-ab48-a8ce7dba692e"><emphasis role="italic">The cluster shade of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_d0c29586-9a48-4c89-bf11-9b860162ae49"><emphasis role="italic">See F<subscript>cm.clust.shade</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.22.0, IBSI, "Cluster Shade of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128797"><emphasis role="italic">128797</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_d3f0385a-8d7c-4a7c-881c-794e67cd34f2"><emphasis role="italic">Cluster Prominence of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_2f4d97b0-3989-4036-a01b-2788a26ff5d1"><emphasis role="italic">The cluster prominence of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_51eb1717-234e-420f-a3b5-61668fa6f159"><emphasis role="italic">See F<subscript>cm.clust.prom</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.23.0, IBSI, "Cluster Prominence of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128798"><emphasis role="italic">128798</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_c1c11be2-f548-4029-8798-324257620c96"><emphasis role="italic">First Measure of Information Correlation of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_df7da025-0ed3-4d26-b694-c3e283bb4512"><emphasis role="italic">The first measure of information correlation of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_42ee27b0-c181-4636-a58d-f46d75ef4332"><emphasis role="italic">See F<subscript>cm.info.corr.1</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.24.0, IBSI, "First Measure of Information Correlation of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128799"><emphasis role="italic">128799</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_55b1e35e-7560-493a-b2a7-518165b19801"><emphasis role="italic">Second Measure of Information Correlation of GLCM</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_ee32eaf5-7263-49a8-b22b-a46309cd087d"><emphasis role="italic">The second measure of information correlation of a Gray Level Co-occurrence Matrix (GLCM).</emphasis></para>
                  <para xml:id="para_406fe7da-1f75-4a33-9698-7f6f5222f372"><emphasis role="italic">See F<subscript>cm.info.corr.2</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.6.25.0, IBSI, "Second Measure of Information Correlation of GLCM")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>









            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128801"><emphasis role="italic">128801</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_e6c9a2a6-27c7-43c5-804b-b4efd4f5e95b"><emphasis role="italic">Short Runs Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_8ca0e1b6-15ad-461a-8f1a-f4a6f41270e3"><emphasis role="italic">A measure of the distribution of short runs in a gray level run length matrix. Abbreviated SRE.</emphasis></para>
                  <para xml:id="para_8353bf53-675f-41ce-be3e-31e6ba4e99cc"><emphasis role="italic">See F<subscript>rlm.sre</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.1.0, IBSI, "Short Runs Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128802"><emphasis role="italic">128802</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_407a305f-721d-4582-b748-e8581aea0d1e"><emphasis role="italic">Long Runs Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_cc5fc4bd-6a61-4cc3-b425-3c4d70ffff65"><emphasis role="italic">A measure of the distribution of long runs in a gray level run length matrix. Abbreviated LRE.</emphasis></para>
                  <para xml:id="para_195d9fc0-c3ef-4b69-806b-0ec08573c0af"><emphasis role="italic">See F<subscript>rlm.lre</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.2.0, IBSI, "Long Runs Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128803"><emphasis role="italic">128803</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_0643edfe-3b59-4abb-8321-91605623e59e"><emphasis role="italic">Low Gray Level Run Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_8862cc2b-3d05-4873-b9dc-d69ab1f98553"><emphasis role="italic">A measure of the distribution of low gray level values in a gray level run length matrix. Abbreviated LGRE.</emphasis></para>
                  <para xml:id="para_be7c09fe-58ce-464f-a854-0c0f35a8cba4"><emphasis role="italic">See F<subscript>rlm.lgre</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.3.0, IBSI, "Low Gray Level Run Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128804"><emphasis role="italic">128804</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_b7bc2a03-ef56-482a-9a78-fa8bf366c4ff"><emphasis role="italic">High Gray Level Run Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_a2c50ddb-a355-4fc5-8c1a-b049960ec1a2"><emphasis role="italic">A measure of the distribution of high gray level values in a gray level run length matrix. Abbreviated HGRE.</emphasis></para>
                  <para xml:id="para_09490b7f-293c-4b15-bc98-1db0e49ada24"><emphasis role="italic">See F<subscript>rlm.hgre</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_5338081c-c58c-4375-9aa1-23c1ac6eb95b"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.4.0, IBSI, "High Gray Level Run Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128805"><emphasis role="italic">128805</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_ea548a12-7b3f-4354-89ed-0f610c9fb347"><emphasis role="italic">Short Run Low Gray Level Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_55b74e72-2c7c-4fd0-af89-edadcc8367f9"><emphasis role="italic">A measure of the joint distribution of short runs and low gray level values in a gray level run length matrix. Abbreviated SRLGE.</emphasis></para>
                  <para xml:id="para_89bb0f4d-7c30-4af2-b234-de6a0eadc5a2"><emphasis role="italic">See F<subscript>rlm.srlge</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_94e42337-729e-468c-9643-35f923d96322"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.5.0, IBSI, "Short Run Low Gray Level Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128806"><emphasis role="italic">128806</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_73c1bb49-f908-426f-b9ea-a6e10f0b9e25"><emphasis role="italic">Short Run High Gray Level Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_6cd80ceb-0b97-492e-ab8c-0d170ee1dbb4"><emphasis role="italic">A measure of the joint distribution of short runs and high gray level values in a gray level run length matrix. Abbreviated SRHGE.</emphasis></para>
                  <para xml:id="para_5768780f-9280-44c9-80ba-667cc5e43f7e"><emphasis role="italic">See F<subscript>rlm.srhge</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_8a4a69fa-2193-46d7-b0aa-cefe13af07d6"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.6.0, IBSI, "Short Run High Gray Level Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128807"><emphasis role="italic">128807</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_bab55bce-7cc1-4377-b7f5-c130dcb2bc0b"><emphasis role="italic">Long Run Low Gray Level Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_9784badc-e8e5-444b-b431-122f3ae23131"><emphasis role="italic">A measure of the joint distribution of long runs and low gray level values in a gray level run length matrix. Abbreviated LRLGE.</emphasis></para>
                  <para xml:id="para_267ebe84-24ea-42cc-b578-d4393acf12fb"><emphasis role="italic">See F<subscript>rlm.lrlge</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_a59c600a-4631-4e61-8b62-b3c8ba77545e"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.7.0, IBSI, "Long Run Low Gray Level Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128808"><emphasis role="italic">128808</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_e468d9ca-6219-440b-8532-7064cebf34c9"><emphasis role="italic">Long Run High Gray Level Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_034bbd31-bfd6-478e-aee9-b2386bfa3868"><emphasis role="italic">A measure of the the joint distribution of long runs and high gray level values in a gray level run length matrix. Abbreviated LRHGE.</emphasis></para>
                  <para xml:id="para_3cfd08d5-0477-4086-8998-f4f87deebd3f"><emphasis role="italic">See F<subscript>rlm.lrhge</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_3252e73a-fbac-4316-8ac5-662b62ccd0e3"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.8.0, IBSI, "Long Run High Gray Level Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128809"><emphasis role="italic">128809</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_247f64b7-d548-48d6-9a34-f0278edbac26"><emphasis role="italic">Gray Level Nonuniformity in Runs</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_dd33c44f-0282-469e-812a-fef338d8fe60"><emphasis role="italic">A measure of the similarity of gray level values throughout the image in a gray level run length matrix. Abbreviated RLM.GLNU.</emphasis></para>
                  <para xml:id="para_9af11840-e0bc-43d6-a065-e1148ab622cd"><emphasis role="italic">See F<subscript>rlm.glnu</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_f48a9045-7c67-4ec2-bc6d-6de39ce69648"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.9.0, IBSI, "Gray Level Nonuniformity in Runs")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128810"><emphasis role="italic">128810</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_6d2ac74c-efa8-461f-99c2-b682845c28d9"><emphasis role="italic">Gray Level Nonuniformity in Runs Normalized</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_e486ee44-0c9c-4fb7-ae52-acded22be55d"><emphasis role="italic">A normalized measure of the similarity of gray level values throughout the image in a gray level run length matrix.</emphasis></para>
                  <para xml:id="para_8b79880a-f7eb-44f8-bda6-d224ff456735"><emphasis role="italic">See F<subscript>rlm.glnu.norm</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_f4963cd8-f569-4a49-a7cc-48ecf0d0b113"><emphasis role="italic">The US not UK spelling of "normalized" is used to be consistent with the DICOM convention, rather than the IBSI spelling.</emphasis></para>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.10.0, IBSI, "Normalized Gray Level Nonuniformity in Runs")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128811"><emphasis role="italic">128811</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_0f57b30d-72d6-4a85-b1c9-2eb9208a61f8"><emphasis role="italic">Run Length Nonuniformity</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_3d988b67-41f5-4ca2-81c4-2b333cf484e7"><emphasis role="italic">A measure of the the similarity of the length of runs throughout the image in a gray level run length matrix. Abbreviated RLNU.</emphasis></para>
                  <para xml:id="para_3d41e4bf-6f29-4609-8785-fca0d52bb88b"><emphasis role="italic">See F<subscript>rlm.rlnu</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_38ba12c3-d3f8-488e-821a-09754d67d026"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.11.0, IBSI, "Run Length Nonuniformity")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128812"><emphasis role="italic">128812</emphasis></para>
               </td>
               <td align="left" colspan="1">
                   <para xml:id="para_fb721fd0-e9bd-4729-8a91-faf8d0b7940a"><emphasis role="italic">Run Length Nonuniformity Normalized</emphasis></para>
                            </td>
               <td align="left" colspan="1">
                  <para xml:id="para_a7a19e15-4280-4ab4-be96-fa9e347b7e22"><emphasis role="italic">A normalized measure of the the similarity of the length of runs throughout the image in a gray level run length matrix.</emphasis></para>
                  <para xml:id="para_b845bfb7-6a22-4f2c-88c1-5a312660f0dc"><emphasis role="italic">See F<subscript>rlm.rlnu.norm</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_d5d1c52c-6ee5-4f92-a2c7-3be78d8bd6f5"><emphasis role="italic">The US not UK spelling of "normalized" is used to be consistent with the DICOM convention, rather than the IBSI spelling.</emphasis></para>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.12.0, IBSI, "Normalized Run Length Nonuniformity")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128813"><emphasis role="italic">128813</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_a1f9b73f-8ada-4950-ab58-a602683f4929"><emphasis role="italic">Run Percentage</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_ab4aebd0-e870-4bbe-9c15-5b3f95c133a1"><emphasis role="italic">A measure of the homogeneity and distribution of runs of an image in a specific direction in a gray level run length matrix. Abbreviated RPC.</emphasis></para>
                  <para xml:id="para_5c175213-57c4-4df2-83ae-02736e0962ce"><emphasis role="italic">See F<subscript>rlm.r.perc</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_a27e7665-8e1d-483a-a584-44bc36e67590"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.13.0, IBSI, "Run Percentage")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128814"><emphasis role="italic">128814</emphasis></para>
               </td>
               <td align="left" colspan="1">
                   <para xml:id="para_b5b94bb6-09bf-44a2-8889-22d3b3447205"><emphasis role="italic">Gray Level Variance in Runs</emphasis></para>
                            </td>
               <td align="left" colspan="1">
                  <para xml:id="para_edcb1038-db3a-4982-8fa9-195c4f8b59a2"><emphasis role="italic">The variance in runs for the gray levels in a gray level run length matrix.</emphasis></para>
                  <para xml:id="para_9ecb811a-6dbe-4ded-879d-b5ec347817a5"><emphasis role="italic">See F<subscript>rlm.gl.var</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_b5a8ed92-486b-4563-9ce8-f84d2b52f97d"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.14.0, IBSI, "Gray Level Variance in Runs")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_128815"><emphasis role="italic">128815</emphasis></para>
                        </td>
                        
                            <td align="left" colspan="1">
                                <para xml:id="para_80ecb47d-9be0-4f48-b5e2-8700e1ff8c7e"><emphasis role="italic">Run Length Variance</emphasis></para>
                            </td>
                        
                        <td align="left" colspan="1">
                            <para xml:id="para_4648c348-5313-4250-8352-a6b12dd92017"><emphasis role="italic">The variance in runs for run lengths in a gray level run length matrix.</emphasis></para>
                            <para xml:id="para_17d27c3b-b577-4948-8ee3-06f7a3a60ff5"><emphasis role="italic">See F<subscript>rlm.rl.var</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
                        </td>
                        <td align="left" colspan="1">
                            <para xml:id="para_ad0fea1e-388a-4840-99e3-cddf6b461578"/>
                            <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                            <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.15.0, IBSI, "Run Length Variance")</emphasis></emphasis></emphasis></para>
                        </td>
                    </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128816"><emphasis role="italic">128816</emphasis></para>
               </td>
               <td align="left" colspan="1">
                   <para xml:id="para_1ec15a75-0898-4e81-bb80-7fb33b3759e1"><emphasis role="italic">Run Entropy</emphasis></para>
                            </td>
               <td align="left" colspan="1">
                  <para xml:id="para_10766b0f-d61c-4fc9-9441-910bf61f21e6"><emphasis role="italic">The entropy of runs in a gray level run length matrix.</emphasis></para>
                  <para xml:id="para_5fd7387b-8fd2-409d-9f38-1a543652669b"><emphasis role="italic">See F<subscript>rlm.rl.entr</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_17341765-41fc-43d3-9cb4-814fd3628e9f"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.7.16.0, IBSI, "Run Entropy")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>


            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128821"><emphasis role="italic">128821</emphasis></para>
               </td>
               <td align="left" colspan="1">
                   <para xml:id="para_8c45228a-e394-492b-97d7-0e56bf25aaae"><emphasis role="italic">Small Zone Emphasis</emphasis></para>
                            </td>
               <td align="left" colspan="1">
                  <para xml:id="para_db1baa68-a1d8-4cac-8c00-1f16419f2702"><emphasis role="italic">A feature that emphasizes small zones from a gray level size zone matrix. Abbreviated SZE.</emphasis></para>
                  <para xml:id="para_a9ad375e-b433-4d0d-a677-e30b48362dce"><emphasis role="italic">See F<subscript>szm.sze</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_eb89056a-d808-43a7-9586-06506ad6957e"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.1.0, IBSI, "Small Zone Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128822"><emphasis role="italic">128822</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_b8353dd8-7a0f-49cb-bb40-ff320e545f31"><emphasis role="italic">Large Zone Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_1985a7c9-03d2-4368-9c9e-346b019d7f86"><emphasis role="italic">A feature that emphasizes large zones from a gray level size zone matrix. Abbreviated LZE.</emphasis></para>
                  <para xml:id="para_26a070d9-5094-4598-9d96-31a303c43eb0"><emphasis role="italic">See F<subscript>szm.lze</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_fbd18cde-b8b8-4020-9f5a-68569dfe775c"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.2.0, IBSI, "Large Zone Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128823"><emphasis role="italic">128823</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_f15ec62e-7ece-4fc4-b6cc-c1b9ddab0b88"><emphasis role="italic">Low Gray Level Zone Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_0af7d283-0b6d-45b7-a2ba-ac3f0b3f99b7"><emphasis role="italic">A feature that emphasizes low gray level zones from a gray level size zone matrix. Abbreviated LGZE.</emphasis></para>
                  <para xml:id="para_561aa4d3-8521-43d9-80ac-8622d254217f"><emphasis role="italic">See F<subscript>szm.lgze</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_0b1da6c9-4445-4db8-abb2-944e4deeccb5"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.3.0, IBSI, "Low Gray Level Zone Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128824"><emphasis role="italic">128824</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_506c3763-62ef-44c0-8ccd-40492d46d314"><emphasis role="italic">High Gray Level Zone Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_4b902865-59bd-43eb-90c1-97338aa37916"><emphasis role="italic">A feature that emphasizes high gray level zones from a gray level size zone matrix. Abbreviated LGZE.</emphasis></para>
                  <para xml:id="para_3aabdd52-6c1a-46dc-a916-c4d08dfbd82b"><emphasis role="italic">See F<subscript>szm.hgze</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_ef199ce4-223c-4ed3-bf71-d28057179694"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.4.0, IBSI, "High Gray Level Zone Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128825"><emphasis role="italic">128825</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_3c064e1f-813a-4470-9978-9b5c27ce115d"><emphasis role="italic">Small Zone Low Gray Level Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_62f5175b-a81f-448a-a064-2dd72b3f3e3f"><emphasis role="italic">A feature that emphasizes small zone sizes and low gray levels from a gray level size zone matrix. Abbreviated SZLGE.</emphasis></para>
                  <para xml:id="para_db76040b-ad4c-4393-b3b6-d82f68a0a94f"><emphasis role="italic">See F<subscript>szm.szlge</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_7c3a1dd1-a7fd-4854-88bc-b5a57f0cadf1"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.5.0, IBSI, "Small Zone Low Gray Level Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128826"><emphasis role="italic">128826</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_6c3f5650-5e70-4e7e-b05c-6e3975457959"><emphasis role="italic">Small Zone High Gray Level Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_c0e72382-f397-41f6-a909-b679c749597c"><emphasis role="italic">A feature that emphasizes small zone sizes and high gray levels from a gray level size zone matrix. Abbreviated SZHGE.</emphasis></para>
                  <para xml:id="para_5ccc1494-2d30-4725-bb85-8a6afcb33dc5"><emphasis role="italic">See F<subscript>szm.szhge</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_63cdfec8-c8e7-4dc1-90d8-6f36b98a3d81"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.6.0, IBSI, "Small Zone High Gray Level Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128827"><emphasis role="italic">128827</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_53a5f96d-cca8-4b28-916d-2dc3c08d5b22"><emphasis role="italic">Large Zone Low Gray Level Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_0bb896da-92e4-4653-a618-cc9faedc1400"><emphasis role="italic">A feature that emphasizes large zone sizes and low gray levels from a gray level size zone matrix. Abbreviated LZLGE.</emphasis></para>
                  <para xml:id="para_78b30b6e-8fc5-4703-9f3e-9aca4f8a2a60"><emphasis role="italic">See F<subscript>szm.lzlge</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_545c3e33-8a0c-496b-b5bc-51f15ed767cc"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.7.0, IBSI, "Large Zone Low Gray Level Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128828"><emphasis role="italic">128828</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_e3773704-82db-4f5b-af08-62ccba878002"><emphasis role="italic">Large Zone High Gray Level Emphasis</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_589cb360-fd5a-43c7-bc79-32e02679ec2c"><emphasis role="italic">A feature that emphasizes large zone sizes and high gray levels from a gray level size zone matrix. Abbreviated LZHGE.</emphasis></para>
                  <para xml:id="para_ed751696-a452-407b-a577-c6c355114b85"><emphasis role="italic">See F<subscript>szm.lzhge</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_9b7b43f3-e8d4-4195-92cb-1f5809a6c9c3"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.8.0, IBSI, "Large Zone High Gray Level Emphasis")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128829"><emphasis role="italic">128829</emphasis></para>
               </td>
               <td align="left" colspan="1">
                   <para xml:id="para_82f9734c-2d6f-46bf-a283-c480cea6d870"><emphasis role="italic">Gray Level Nonuniformity of Zone Counts</emphasis></para>
                            </td>
               <td align="left" colspan="1">
                  <para xml:id="para_d942e99c-3afb-420d-97ed-57975604d1ca"><emphasis role="italic">The distribution of zone counts over the gray values in a gray level size zone matrix. Abbreviated SZM.GLNU.</emphasis></para>
                  <para xml:id="para_8432de88-af4e-46c2-8e03-72ae64e42d71"><emphasis role="italic">See F<subscript>szm.glnu</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_771ab740-98c2-4ac7-9ae7-da603473f43f"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.9.0, IBSI, "Gray Level Nonuniformity of Size Zone Counts")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128830"><emphasis role="italic">128830</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_cb982179-bb64-4634-b6ef-282d448d4a45"><emphasis role="italic">Gray Level Nonuniformity of Zone Counts Normalized</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_3f0ce99d-0538-4a8c-9ac7-a422128b3494"><emphasis role="italic">The normalized distribution of zone counts over the gray values in a gray level size zone matrix.</emphasis></para>
                  <para xml:id="para_cd6f2cd3-a984-44b5-bbcb-75e9c4ef07e0"><emphasis role="italic">See F<subscript>szm.glnu.norm</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_353919b1-58fd-4aa2-b8ba-5db288a311b5"><emphasis role="italic">The US not UK spelling of "normalized" is used to be consistent with the DICOM convention, rather than the IBSI spelling.</emphasis></para>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.10.0, IBSI, "Normalized Gray Level Nonuniformity of Size Zone Counts")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128831"><emphasis role="italic">128831</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_7e414808-269d-47fb-8f41-325ea1a62978"><emphasis role="italic">Zone Size Nonuniformity</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_b49390aa-ed17-4373-8339-9fe21180ec61"><emphasis role="italic">The distribution of zone counts over the different zone sizes in a gray level size zone matrix. Abbreviated ZSNU.</emphasis></para>
                  <para xml:id="para_6e4e6ec8-4367-4392-b892-d48ba4eaf932"><emphasis role="italic">See F<subscript>szm.zsnu</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_b73be022-cb6e-48ad-88f3-edc94ad2b1db"/>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.11.0, IBSI, "Zone Size Nonuniformity")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128832"><emphasis role="italic">128832</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_9ee91305-d795-4eee-b322-01cf1892fcc2"><emphasis role="italic">Zone Size Nonuniformity Normalized</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_6f34fe04-0977-4ae9-9ba0-30e0057b4377"><emphasis role="italic">The normalized distribution of zone counts over the different zone sizes in a gray level size zone matrix.</emphasis></para>
                  <para xml:id="para_50eed0d7-db82-46c5-a6ca-4691eb54be1f"><emphasis role="italic">See F<subscript>szm.zsnu.norm</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_1cc4f2bf-a64e-44b9-a051-39b111a8bd46"><emphasis role="italic">The US not UK spelling of "normalized" is used to be consistent with the DICOM convention, rather than the IBSI spelling.</emphasis></para>
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.12.0, IBSI, "Normalized Zone Size Nonuniformity")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128833"><emphasis role="italic">128833</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_c2ae3d84-3a2f-4484-9b5b-cdd944169795"><emphasis role="italic">Zone Percentage</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_fee7d6cd-f9bd-4e9f-95cb-9389b9b44fab"><emphasis role="italic">The fraction of the number of realised zones relative to the maximum number of potential zones in a gray level size zone matrix. Abbreviated ZPERC.</emphasis></para>
                  <para xml:id="para_3de97cf0-2be6-4777-8ff1-a0fbc9577786"><emphasis role="italic">See F<subscript>szm.z.perc</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.13.0, IBSI, "Size Zone Percentage")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128834"><emphasis role="italic">128834</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_c22311d3-5fc8-4ded-aff8-3160d222f1eb"><emphasis role="italic">Gray Level Variance in Zones</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_d54594e0-c40b-4bcf-9877-5603c0269d9d"><emphasis role="italic">The variance ithe variance in zone counts for the gray levels in a gray level size zone matrix.</emphasis></para>
                  <para xml:id="para_6a09b174-b438-45a8-a671-67d3cea382f1"><emphasis role="italic">See F<subscript>szm.gl.var</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.14.0, IBSI, "Gray Level Variance in Size Zones")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128835"><emphasis role="italic">128835</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_cff18d1c-649a-4c21-bbd1-c637531f8633"><emphasis role="italic">Zone Size Variance</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_189b3b8b-609d-4b6e-a9d3-e3f04eea8443"><emphasis role="italic">The variance in zone counts for the different zone sizes in a gray level size zone matrix.</emphasis></para>
                  <para xml:id="para_5c51883a-0af0-4008-a5b3-9b09d87b164f"><emphasis role="italic">See F<subscript>szm.zs.var</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.15.0, IBSI, "Zone Size Variance")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

            <tr>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="DCM_128836"><emphasis role="italic">128836</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_24b465c2-2d0a-4523-bc9d-2c94a52f0401"><emphasis role="italic">Zone Size Entropy</emphasis></para>
               </td>
               <td align="left" colspan="1">
                  <para xml:id="para_bfcf2b31-daa5-4f29-80a7-48bd411c5129"><emphasis role="italic">The entropy of zone sizes in a gray level size zone matrix.</emphasis></para>
                  <para xml:id="para_ef64f33a-2189-4a94-91a8-fd662d9d273d"><emphasis role="italic">See F<subscript>szm.zs.entr</subscript> in <xref linkend="biblio_IBSI_Features"/>.</emphasis></para>
               </td>
               <td align="left" colspan="1">
                                      <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Retired</emphasis></emphasis></emphasis></para>
                       <para><emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Replaced by (1.8.16.0, IBSI, "Zone Size Entropy")</emphasis></emphasis></emphasis></para>
                   </td>
                </tr>

               <tr>
                  <td align="center" colspan="1"/>
                  <td align="left" colspan="1"/>
                  <td align="left" colspan="1"/>
                  <td align="left" colspan="1"/>
               </tr>
                
                
                
                
                
               <tr>
                  <td align="center" colspan="1"/>
                  <td align="left" colspan="1"/>
                  <td align="left" colspan="1"/>
                  <td align="left" colspan="1"/>
               </tr>
                
                <tr>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_ddd051"><emphasis role="bold"><emphasis role="underline">ddd051</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Roughness Maximum Valley Depth</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">The xxxxx.</emphasis></emphasis></para>
                      <para><emphasis role="bold"><emphasis role="underline">See XXXXX in [ref.]</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1">
                      <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                   </td>
                </tr>
                <tr>
                   <td align="center" colspan="1"/>
                   <td align="left" colspan="1"/>
                   <td align="left" colspan="1"/>
                   <td align="left" colspan="1"/>
                </tr>
                
                
         </tbody>
      </table>
   </section>
    </chapter>
</book>