  <title>CP-1742</title>
   <subtitle>Add Performed Protocol Code Sequence wherever Protocol Name occurs</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/01/23</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para>
                    <para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
           <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para>
                 <para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
           </tr>
           <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>2017/08/10</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1742</para></td>
            </tr>
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Performed Protocol Code Sequence wherever Protocol Name occurs</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para>
                   <para>Recent image IODs have included Performed Protocol Code Sequence as a coded alternative to the text Protocol Name.</para>
                   <para>Do the same in the General Series Module so that this capability can be used in all IODs.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
       
       <section label="C.7.3.1" status="4" xml:id="sect_C.7.3.1">
          <title>General Series Module</title>
          <table frame="box" label="C.7-5a" rules="all" xml:id="table_C.7-5a">
            <caption>General Series Module Attributes</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_04100f31-5424-4105-b397-e81ea26cab1a">Attribute Name</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9f6ee2bc-0c72-4acc-bd8a-3b63e075406c">Tag</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7be1655a-1548-4c66-a4a3-2f62a8898dc2">Type</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_28b73666-093e-4904-b24e-ab760754d7a0">Attribute Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_cdb6f0e9-188b-4fda-bc33-00244b78db42">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_573048aa-6706-44a7-b7a9-56c1d9580215">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d64d0571-7bc4-4d9d-b327-23b378fde0d4">...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_181afb38-9c62-4435-a027-a593e36049d8">...</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_3c72fd73-6200-40b9-a3aa-3e3200b8c7a7">Protocol Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_4405d28d-db41-4b21-89b5-c74923935975">(0018,1030)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_638f9ab0-5d17-4c42-bd57-2a9d9280afbf">3</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6641ecc4-3a11-4f71-b9a8-b51d88e62f31">User-defined description of the conditions under which the Series was performed.</para>
                  <note>
                    <para xml:id="para_0dde755c-c6af-40da-92ed-f526337bb396">This attribute conveys series-specific protocol identification and may or may not be identical to the one presented in the Performed Protocol Code Sequence (0040,0260).</para>
                  </note>
                </td>
              </tr>
               <tr valign="top">
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_81663e02-5843-42f5-a2be-be68acab3c3d"><emphasis role="bold"><emphasis role="underline">Performed Protocol Code Sequence</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a278b512-f0bc-4e78-9b6f-76be05605adc"><emphasis role="bold"><emphasis role="underline">(0040,0260)</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4bdf1930-c582-47b4-b16d-4a85a5df51d8"><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_66d716b9-01da-489c-b13a-3d3d7b5e7b75"><emphasis role="bold"><emphasis role="underline">Sequence describing the Protocol performed for the Procedure Step creating the sources.</emphasis></emphasis></para>
                     <para xml:id="para_31400c59-b33f-4a0f-b06c-e7876f4defad"><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this Sequence.</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="left" colspan="3" rowspan="1">
                     <para xml:id="para_d9e42ff1-4a56-4d72-a116-f7b4c50f7c59">
                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                              </emphasis></emphasis></emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_97cae6c5-33ff-4b81-8fe8-a95edc815710">
                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                     </para>
                  </td>
               </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_b4902d11-6caf-4582-adbf-4fe30c7e4368">Referenced Defined Protocol Sequence</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_aef7e55c-282a-4fa8-a697-4f7b1019499a">(0018,990C)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_10e98c4d-f634-4e27-b4a3-15b8a454d5a8">1C</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_59492566-4584-4522-ae95-56a6fcd9e058">Defined Procedure Protocol SOP Instance(s) that were used to create Instances in this Series.</para>
                  <para xml:id="para_c156ac11-b811-4ade-b00a-52ce54f35a34">Required if this instance is a Performed Procedure Protocol that resulted from a Defined Procedure Protocol.</para>
                  <para xml:id="para_067bb85e-5b5b-4089-af64-f7ef2c864f92">May be present otherwise.</para>
                  <para xml:id="para_743132e9-6381-4888-8493-d124d7608449">One or more Items shall be included in this Sequence.</para>
                  <note>
                    <para xml:id="para_0e580e64-a6f5-4cfd-b5c7-23f5f9d63654">Multiple items in this sequence may represent a group case where several Defined Procedure Protocols were performed together as a single Performed Procedure Protocol.</para>
                  </note>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="2" rowspan="1">
                  <para xml:id="para_bf4828be-45fa-4ee6-b130-6246f0acc1d1">
<emphasis role="italic">&gt;Include <xref linkend="table_10-11" xrefstyle="select: label quotedtitle"/>
</emphasis>
</para>
                </td>
                <td align="left" colspan="2" rowspan="1"/>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f6ef0ba7-e40e-400e-9158-e37fd2faa10a">Referenced Performed Protocol Sequence</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_24a864d0-edff-4620-8403-22ac1a2c51c2">(0018,990D)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_96873ec6-4941-45bd-a422-2ea7349060bb">1C</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_50f91f8e-b0a6-44c8-b950-23527a31b62e">Uniquely identifies the Performed Procedure Protocol SOP Instance(s) that describe the conditions by which this Series was generated.</para>
                  <para xml:id="para_95d97010-f703-4532-8b17-5ee450d3a92c">Required if a related Performed Procedure Protocol SOP Instance was created.</para>
                  <para xml:id="para_a12e7fba-ee24-4ae0-b4d6-c6491c4de989">One or more Items shall be included in this Sequence.</para>
                  <note>
                    <para xml:id="para_bdcc61ec-b3aa-4d08-9b5f-764a6c5f0e7e">If the acquisition and reconstruction were recorded in separate Performed Procedure Protocol SOP Instances, it is recommended to reference both. However, it is not intended that this sequence reference Defined or prior Performed Protocol SOP Instances on which the current Performed Procedure Protocol SOP Instance was based. Such references may be found inside the current Performed Procedure Protocol SOP Instance itself.</para>
                  </note>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="2" rowspan="1">
                  <para xml:id="para_8db31b6e-3872-4b2c-a79c-9945154c31f2">
<emphasis role="italic">&gt;Include <xref linkend="table_10-11" xrefstyle="select: label quotedtitle"/>
</emphasis>
</para>
                </td>
                <td align="left" colspan="2" rowspan="1"/>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5fe2ee7d-82fc-44e4-893b-eecb8eb89550">Series Description</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ee19c74f-b420-49da-8ba6-83f679211130">(0008,103E)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_57411262-eee0-48c5-850d-32b87204e9e7">3</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ac5ed193-6b12-49b9-87f5-7f4a11148fc6">Description of the Series</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_46af03ae-e0eb-4164-90e6-b08ca4c52a09">Series Description Code Sequence</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_98473556-a2eb-48c8-845f-923fc35e887b">(0008,103F)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_cf3337bc-00c3-45df-99a4-e638298eaa66">3</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_b07a1f7e-834b-4a56-9b7b-dcd5e94a82e3">A coded description of the Series.</para>
                  <para xml:id="para_e36d8ec6-fd3b-4e98-86a4-3976fc8ad50d">Only a single Item is permitted in this Sequence.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="3" rowspan="1">
                  <para xml:id="para_e5105f2b-9f05-4c3b-bf13-d6c7e3400fb0">
                    <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
</emphasis>
                  </para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e211e927-7966-46d9-8537-d573406c9c6e">
                    <emphasis role="italic">No Baseline CID is defined.</emphasis>
                  </para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_bace2372-d59e-452f-8198-b8c2c21984ba">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_2134b151-96af-4b10-8082-ca3df56a5a6b">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_db12a419-f340-4cf2-8762-db58653820e3">...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c6d14739-df95-4e89-a57c-b74dc4ec8c9e">...</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>