<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
   <title>CP-1741</title>
    <subtitle>Add more PET Radiopharmaceuticals</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/09/13</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para>
                    <para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
           <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para>
                   <para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
           </tr>
           <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>2017/07/12</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1741</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add more PET Radiopharmaceuticals</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para><para>A code is need for Ga68 prostate-specific membrane antigen (PSMA).</para>
                    <para><emphasis role="italic">[Ed.Note.: Do we need other experimental PSMA agents, e.g. 18F-DCFPyL? See <link xl:href="dx.doi.org/10.1158/1078-0432.CCR-11-1357"/>. For codes, see <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C3492634"/>, which duplicates <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C3492635"/> ]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note.: There is a SNOMED procedure code for using PSMA (<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=717777006&amp;edition=en-edition&amp;release=v20170131"/>) but it is specified as "Using substance: ^68^Gallium" rather than a specific radiopharmaceutical. This probably needs to be fixed in SNOMED.] </emphasis></para>
                   <para>A code is needed for C11 sarcosine (see <link xl:href="http://www.snmmi.org/files/FileDownloads/Full%20JNM%20article_C-11-Sarcosine_prostate%20cancer.pdf"/>).</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
                    <section label="CID 4021" status="3" xml:id="sect_CID_4021">
         <title>PET Radiopharmaceutical</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_975ea8ef-40ed-48a3-9c64-59e5093f6222">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_3aaadcf2-0d4e-40c2-9732-208545d28a7d">
                            <emphasis role="bold"><emphasis role="strikethrough">20170413</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
         <varlistentry>
<term>
<emphasis role="bold">UID:</emphasis>
</term>
<listitem>
<para xml:id="para_bf9fdd09-f9be-4af6-a5d9-ec24078f6729">
<emphasis role="bold">1.2.840.10008.6.1.305</emphasis>
</para>
</listitem>
</varlistentry>
</variablelist>
         <table frame="box" label="CID 4021" rules="all" xml:id="table_CID_4021">
            <caption>PET Radiopharmaceutical</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_10c25d91-27c7-4d01-8385-d861df10f3e9">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_91b0c5d5-92b3-4d5a-bbf8-82648fa7f2f4">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5e15bdd4-8016-4671-943b-9eb55cc94f74">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ba3d73d7-fa36-4c62-9ff4-fbe923c664cd">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c644999a-3fd9-43d8-a332-2a157201aeca">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_50d15cd9-82b5-4c18-a066-1a071bfe4e04">
                        <emphasis role="bold">Other Names</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_86ef4ac6-2ede-4d06-ba1a-7317b97a2129">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cf318c87-9353-4180-bb30-b7f540183137">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=129513004" xl:show="new">C-B1043</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_18d030cd-e924-4b6e-aea5-5c8c7fdd6def">Acetate C^11^</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6b8e1dd6-4b2b-4b66-bfc4-80235ac9e06d">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=129513004" xl:show="new">129513004</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9868e60e-dc8f-4f6e-934d-d408eff4e16b">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C1098488" xl:show="new">C1098488</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b28fb9d5-5cf0-4b33-99a2-57d0b022a3e7"/>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para> ... </para>
                  </td>
                  <td align="left" colspan="1">...</td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                  </td>
                  <td align="left" colspan="1">
                     <para>...</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_df52127e-d457-4718-98e7-0061fe39f4e3">DCM</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5ffff382-b255-48e9-938f-6218f8099550">
                        <link linkend="DCM_126703" xrefstyle="select: nopage">126703</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_94df68e9-1187-483a-ad12-46b0e83be904">Choline C^11^</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ce96de17-8b2b-42ba-8068-4faba52eabde"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f94ca099-0c69-40e5-aab1-9f7c8ebc667e"/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_992f48e7-cceb-42c8-98c6-7d49e06cbfa9"/>
                  </td>
               </tr>
               <tr>
                  <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para> ... </para>
                  </td>
                  <td align="left" colspan="1">...</td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                  </td>
                  <td align="left" colspan="1">
                     <para>...</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b4a6bad0-e39c-4fa2-8f95-0c8f0f15c446">UMLS</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b0ed2c7f-c9c8-4b54-b17d-4767175f4adc">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C2713594" xl:show="new">C2713594</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_105b7847-576e-40c2-a751-b51acce6321f">Edotreotide Ga^68^</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4313a356-0163-4d93-9492-877cc4126db5"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1709536e-131c-49b8-a4f3-a076291496ab">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C2713594" xl:show="new">C2713594</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a000442b-31d2-4e7d-830c-0fd881fd5739">DOTATOC, SMT487</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b2858d23-79e0-406e-8918-8aaddb6c6808">...</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0a22a59c-bca3-4e99-b7f3-4998bf0c3bc7"> ... </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d183796e-96fe-4773-b95e-48fdce4b1732">...</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_64cdacb4-3d77-402a-b417-187d2570b7af"> ... </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d406decf-11c0-493d-b7c2-2227abb7706c"> ... </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_dc07300c-b150-4693-92f1-1428fc98bdc0">...</para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">NCIt</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                                <emphasis role="bold"><emphasis role="underline"><link xl:href="https://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C118961" xl:show="new">C118961</link></emphasis></emphasis>
                            </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">PSMA Ga^68^</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para/>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                                <emphasis role="bold"><emphasis role="underline"><link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C3899042" xl:show="new">C3899042</link></emphasis></emphasis>
                            </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Glu‑NH‑CO‑NH‑Lys(Ahx)-HBED‑CC Ga^68^</emphasis></emphasis></para>
                    </td>
                </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">NCIt</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold"><emphasis role="underline"><link xl:href="https://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C122684" xl:show="new">C122684</link></emphasis></emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Sarcosine C^11^</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold"><emphasis role="underline"><link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C4055275" xl:show="new">C4055275</link></emphasis></emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                  </td>
               </tr>

            </tbody>
         </table>
      </section>


        
      
      
      
      
      


    </chapter>
</book>