    <title>CP-1710</title>
    <subtitle>Correct attribute names in segmentation coding example figure</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>November 2017 Packet</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/09/13</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para>
                    <para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>QIICR</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/04/02</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1710</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Correct attribute names in segmentation coding example figure</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.17</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The names of the attributes illustrated in Figure HH-1 "Segment Sequence Structure and References" need to be corrected.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.17 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="HH" status="1" xml:id="chapter_HH">
            <title>Segmentation Encoding Example (Informative)</title>
            <para xml:id="para_8fd8a489-9fa2-4c33-ba13-a951504b05e8">
                <xref linkend="figure_HH-1" xrefstyle="select: label"/> depicts an example of how the data is organized within an instance of the Segmentation IOD. Each item in the Segment Sequence provides the attributes of a segment. The source image used in all segmentations is referenced in the Shared Functional Groups Sequence. Each item of the Per-frame Functional Groups Sequence maps a frame to a segment. The Pixel Data classifies the corresponding pixels/voxels of the source Image.</para>
            <para xml:id="para_dff789c4-c2ab-4228-aaed-49c4e4283519">
                <figure label="HH-1" pgwide="1" xml:id="figure_HH-1">
                    <title>Segment Sequence Structure and References</title>
                    
                <informaltable rules="all" frame="box">
                    <tr>
                        <td>
                            <para><emphasis role="italic">Replace incorrect figure:</emphasis></para>
                        </td>
                    </tr>
                </informaltable>
                
                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="cp1710/PS3.17_HH-1_old.svg"/>
                            <!--<imagedata fileref="figures/PS3.17_HH-1.svg"/>-->
                        </imageobject>
                    </mediaobject>
                
                <informaltable rules="all" frame="box">
                    <tr>
                        <td>
                            <para><emphasis role="italic">with corrected figure:</emphasis></para>
                        </td>
                    </tr>
                </informaltable>

                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="cp1710/PS3.17_HH-1_new.svg"/>
                            <!--<imagedata fileref="figures/PS3.17_HH-1.svg"/>-->
                        </imageobject>
                    </mediaobject>
                    
                </figure>
            </para>
        </section>
        

    </chapter>
</book>