<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1697</title>
  <subtitle>More structure of rather than entire SNOMED anatomical concepts</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>June 2017 Voting Packet</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/06/07</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>2017/01/19</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1697</para></td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Log Summary: More structure of rather than entire SNOMED anatomical concepts</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                  <para>The policy to use "structure of" rather than "entire" has not been followed everywhere. Correct accordingly.</para>
               <para>In selected places, the the concept of "entire" is intended, e.g., entire body (Annex L), entire vessel (CID 3019).</para>
                   <para><emphasis role="italic">[Ed. Note. Request ID 720265 to add to SNOMED DICOM subset: 11279006, 18149002, 24865005, 25991003, 41313007, 44830000, 53118009, 53967007, 62555009, 70253006, 73931004, 74156002, 75772009, 86547008, 88454005, 117590005, 123851003, 125682004, 128320002, 195416006, 244669006, 272657006, 281231009, 284639000, 367624001, 714483002].</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
  <chapter>
    <title/>

    <informaltable rules="all" frame="box">
      <tr>
        <td>
          <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
        </td>
      </tr>
    </informaltable>
    
   <section label="A" status="1" xml:id="chapter_A">
      <title>Structured Reporting Templates (Normative)</title>
      <section label="Cath Lab Clinical Report Templates"
               status="2"
               xml:id="sect_CathLabClinicalReportTemplates">
         <title/>
         <section label="TID 3814" status="3" xml:id="sect_TID_3814">
            <title>Left Ventriculography Findings</title>
            <table frame="box"
                   label="TID 3814"
                   rules="all"
                   xml:id="table_TID_3814">
               <caption>Left Ventriculography Findings</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9ac59f88-e0fc-44b0-9aaf-fb02e0d21175"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_822a89ef-93ee-4edd-900e-c478c14dc710">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f77b1916-8dec-45cb-9cde-44432c2e7bae">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_405811a6-ba62-442e-87b7-19b588825901">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d63ee02a-2e9c-4392-ba51-b86c10227ea8">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_58e1ce56-2605-442f-9703-c36af7ea8bea">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f3cba74b-069c-43a2-a0d0-b80967d97dc5">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_93cbab80-1e69-49dc-9cce-72d71586c829">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_76a91188-1a98-48ac-b83a-b443b811d10b">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f8c9c8df-e37a-4ac7-8c75-1f1b685dd6fc">11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fca1e8ad-9cee-47ec-bfbf-354c0196aa80">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_edf3f969-419b-4569-856a-372cec2d9aad">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0ce8e6c3-6e00-4c80-9f17-f5139a1965d3">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dc2f3caa-4878-4619-a549-fa2452ace588">EV<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=363698007"
                                 xl:show="new">(G-C0E3, SRT, "Finding Site")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6422b837-c3fe-4b7d-a205-323cdf20c2bc">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d3ecfdb3-5f78-4d3e-9057-c5011b408d2b">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_98e4523a-28c2-4582-a9bf-fd17e4b8b404"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e6d86e3c-169e-44de-9b46-5176914425c3">DT<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=181293005"
                                 xl:show="new">(<emphasis role="bold">
                                 <emphasis role="strikethrough">T-D0772</emphasis>
                                 <emphasis role="underline">T-D075D</emphasis>
                              </emphasis>, SRT, "Myocardial Wall")</link>
                        </para>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>
      </section>
      <section label="CT/MR Cardiovascular Analysis Report Templates"
               status="2"
               xml:id="sect_CTMRCardiovascularAnalysisReportTemplates">
         <title/>
         <section label="TID 3902" status="3" xml:id="sect_TID_3902">
            <title>Vascular Analysis</title>
            <table frame="box"
                   label="TID 3902"
                   rules="all"
                   xml:id="table_TID_3902">
               <caption>Vascular Analysis</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_112fdc5d-f36c-4fcc-925b-4cd9a948d879"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_40f793ed-0108-414c-95ae-120bceb0a4e2">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ed8cc5ce-0107-45c5-bc2a-2584c37197c5">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b74df532-832a-452a-af7f-fd0909664186">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e3dd22cb-0ec6-49e1-a8dd-86681f504d0d">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f4002115-8700-4f68-af42-448d32125c85">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9c1d2bd0-5c1f-4db7-a9f4-59102f5fa5b9">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_bd06156a-0031-4fa0-a0b4-ac8244c74191">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ad9e2219-ab3a-4d4b-976a-a91e4f9ad618">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_910a307d-e488-43da-a86d-5c2281b2cd24">4</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9a37797d-a131-4903-a44a-cd31c8f1766d">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c203aa2c-0afe-42fa-a49e-4070629ced89">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_94291be5-f420-449b-b741-018e6986f08d">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7a99e95f-6eed-48bc-bd83-aee5901afabc">D<xref linkend="sect_TID_3906"
                                 xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b01343b0-55fb-4540-9082-11ce4c34022c">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_de747cf4-3916-428d-a344-6245cb452c94">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fa7077a6-fbb8-42c5-b128-1f42e9d66df5"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_084c9292-557a-4949-a2fa-b14ffe51ddb1">$VascularSection = DT<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=127865000"
                                 xl:show="new">(<emphasis role="bold">
                                 <emphasis role="strikethrough">T-40501</emphasis>
                                 <emphasis role="underline">T-D0767</emphasis>
                              </emphasis>, SRT, "Blood Vessel of Head")</link>
                        </para>
                        <para xml:id="para_d947d12a-18d5-4be3-a27a-5d69c14167c4">$SectionLaterality = EV<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=7771000"
                                 xl:show="new">(G-A101, SRT, "Left")</link>
                        </para>
                        <para xml:id="para_0b9f099b-b9f6-4dc0-b249-c8f3fded5198">$Anatomy = D<xref linkend="sect_CID_12105" xrefstyle="select: labelnumber quotedtitle"/>
                        </para>
                        <para xml:id="para_5bb086c5-3c54-4b5e-bc26-9b2116200451">$AnalysisPerformed = $AnalysisPerformed</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_da297061-a809-4f3c-9702-464739d296c0">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2689cf63-b3c3-46c9-83bd-358339225b3a">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ef61d675-f806-4454-8c4a-79c7c4ab70c1">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_30582052-0d8e-4d0d-b193-cac01270da54">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_23070124-d5ec-4217-a4ac-e4c152716f55">D<xref linkend="sect_TID_3906"
                                 xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_58fec7cc-3754-4a72-885e-22f947b1372f">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_97021da1-e911-4551-a74a-f578be115e23">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d9cebd99-cca1-4e4c-b8ba-c77554dd71de"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a16e01f7-80cc-47fe-90c7-e288d715cb83">$VascularSection = DT<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=127865000"
                                 xl:show="new">(<emphasis role="bold">
                                 <emphasis role="strikethrough">T-40501</emphasis>
                                 <emphasis role="underline">T-D0767</emphasis>
                              </emphasis>, SRT, "Blood Vessel of Head")</link>
                        </para>
                        <para xml:id="para_0ef8193f-2f54-4b8f-99e9-aaa88b596989">$SectionLaterality = EV<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=24028007"
                                 xl:show="new">(G-A100, SRT, "Right")</link>
                        </para>
                        <para xml:id="para_cd7e1bcb-25cb-431c-bad5-11f5c6ca54e4">$Anatomy = D<xref linkend="sect_CID_12105" xrefstyle="select: labelnumber quotedtitle"/>
                        </para>
                        <para xml:id="para_bf21baee-7d16-46ae-a812-dd18bea04cec">$AnalysisPerformed = $AnalysisPerformed</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a773ff29-e485-4169-aeb4-eec3221fc3bb">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2d34185d-3520-41d4-81a3-8a20ba5b41c0">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7ed76cf7-8472-423b-b8ec-6f7d374d3646">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5ddbde5b-8ee8-4636-b7c9-bca4d1ebc80c">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0de349ac-e978-4efa-af29-f6788adfb2c6">D<xref linkend="sect_TID_3906"
                                 xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_93627998-bb11-4ac7-a5a2-e5e3bae7ccdd">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1ae11b95-62bc-470b-97d2-0c39b40883c5">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dd7a98c2-1a54-42e6-b29d-0c90fae3702f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8a41f92a-d952-4657-8c84-b04be55d97d7">$VascularSection = DT<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=127865000"
                                 xl:show="new">(<emphasis role="bold">
                                 <emphasis role="strikethrough">T-40501</emphasis>
                                 <emphasis role="underline">T-D0767</emphasis>
                              </emphasis>, SRT, "Blood Vessel of Head")</link>
                        </para>
                        <para xml:id="para_5d62f920-94c4-4056-a5c1-6e838e993e0f">$SectionLaterality = EV<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=66459002"
                                 xl:show="new">(G-A103, SRT, "Unilateral")</link>
                        </para>
                        <para xml:id="para_efc31ed3-2558-49c8-99d6-e7187dac4579">$Anatomy = D<xref linkend="sect_CID_12106" xrefstyle="select: labelnumber quotedtitle"/>
                        </para>
                        <para xml:id="para_63deb8cc-1735-4b0a-b61d-201485772d8f">$AnalysisPerformed = $AnalysisPerformed</para>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>
      </section>
      <section label="Vascular Ultrasound Report Templates"
               status="2"
               xml:id="sect_VascularUltrasoundReportTemplates">
         <title/>
         <section label="TID 5100" status="3" xml:id="sect_TID_5100">
            <title>Vascular Ultrasound Report</title>
            <table frame="box"
                   label="TID 5100"
                   rules="all"
                   xml:id="table_TID_5100">
               <caption>Vascular Ultrasound Report</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_892c5825-fbe3-49b2-838c-eb4703616af8"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_504173d7-4393-4fd8-8021-af9100b4974d">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_31db01ff-f798-42f0-8707-a5d0f93a2d2a">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9c74b4b3-5f79-4cae-aa7d-2cf08636040c">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_68683e46-2e85-48af-808e-98e00ff84f37">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b727a28b-9072-4586-abcb-059e66499024">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2fe361f1-8561-4e27-b21e-fb7432547850">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_af5c16cc-af69-4619-8861-e186894d7faa">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6ffce94c-8544-442d-8338-378575336c6f">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cde62aea-fa06-4e7d-a99f-a97f6933db1d">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e55be597-8e75-415e-89a4-f2301f6dc84b">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_11c534b5-2237-48e7-939e-6097e171b841">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fd2cf754-76a3-48a3-9010-67d3519e86d2">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_502d92e1-3328-4667-ba2e-8ca9210916db">D<xref linkend="sect_TID_5103"
                                 xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2b28bb5d-2623-475d-acaf-7034dafb2df5">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_87e7f20f-db11-4fa7-963c-dca6594c7230">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0aa35686-d603-497a-9d27-3a5a7f14e46c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3d6fbe18-c87f-4613-b6ca-472668bcea5b">$SectionScope = DT<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=127865000"
                                 xl:show="new">(<emphasis role="bold">
                                 <emphasis role="strikethrough">T-40501</emphasis>
                                 <emphasis role="underline">T-D0767</emphasis>
                              </emphasis>, SRT, "Blood Vessel of Head")</link>
                        </para>
                        <para xml:id="para_585e9f1b-7899-4a37-9b6b-bc6db3cbc378">$SectionLaterality = EV<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=7771000"
                                 xl:show="new">(G-A101, SRT, "Left")</link>
                        </para>
                        <para xml:id="para_ccb4c895-3b5f-44b1-84a7-44bc352d1f06">$Anatomy = D<xref linkend="sect_CID_12105" xrefstyle="select: labelnumber quotedtitle"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_74799f9a-5ace-4b3d-b421-ed83f100cfa0">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7d4c8d8c-1e30-413e-b41d-62fc29bac54f">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_396ca81f-f510-4e42-9ae0-51172d9558b8">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8a850d83-ce25-4344-8727-28efa6ee62f7">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7b6f7612-36d7-4654-aab6-7267b8fab7ea">D<xref linkend="sect_TID_5103"
                                 xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ee781f20-1f82-4243-8477-4becee59f0bb">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d9c612d7-03f1-4d88-bf3c-0f0535563fca">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9a119f4f-b59a-4688-ba82-9a76eb769d0f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c4374658-e61e-4b66-9450-a6e63994f803">$SectionScope = DT<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=127865000"
                                 xl:show="new">(<emphasis role="bold">
                                 <emphasis role="strikethrough">T-40501</emphasis>
                                 <emphasis role="underline">T-D0767</emphasis>
                              </emphasis>, SRT, "Blood Vessel of Head")</link>
                        </para>
                        <para xml:id="para_71db90a0-9e30-4e96-b8b5-218771a26902">$SectionLaterality = EV<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=24028007"
                                 xl:show="new">(G-A100, SRT, "Right")</link>
                        </para>
                        <para xml:id="para_e3d76aec-6ef2-462a-bbaf-c87abe8bf35a">$Anatomy = D<xref linkend="sect_CID_12105" xrefstyle="select: labelnumber quotedtitle"/>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_80cac901-4273-461f-b47f-43e7a34f1915">11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_38b9260e-1c6c-457e-92ba-73e9d31cf0d7">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_76c1b541-3da3-4526-8881-4f2c429f557a">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_13d71d4e-4e3e-4735-a6a9-1b0de4fca582">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_63793e03-a74c-4f4f-9526-e60ee1d27c89">D<xref linkend="sect_TID_5103"
                                 xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c37da569-6d78-44b7-94ec-1392cc59a8a6">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_269fde90-64f0-42bf-96c6-7a0e9c24a064">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bc6db600-cddd-40a4-8352-223e1108f1d0"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d42375f8-9df9-4f22-8060-18d6f2e3f35a">$SectionScope = DT<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=127865000"
                                 xl:show="new">(<emphasis role="bold">
                                 <emphasis role="strikethrough">T-40501</emphasis>
                                 <emphasis role="underline">T-D0767</emphasis>
                              </emphasis>, SRT, "Blood Vessel of Head")</link>
                        </para>
                        <para xml:id="para_dd905a4f-7d51-4310-bbd4-228d7af5bea7">$SectionLaterality = EV<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=66459002"
                                 xl:show="new">(G-A103, SRT, "Unilateral")</link>
                        </para>
                        <para xml:id="para_7988f835-cc55-4115-ad48-76ca04d7ea9b">$Anatomy = D<xref linkend="sect_CID_12106" xrefstyle="select: labelnumber quotedtitle"/>
                        </para>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>
      </section>
      <section label="Echocardiography Procedure Report Templates"
               status="2"
               xml:id="sect_EchocardiographyProcedureReportTemplates">
         <title/>
         <section label="TID 5204" status="3" xml:id="sect_TID_5204">
            <title>Wall Motion Analysis</title>
            <table frame="box"
                   label="TID 5204"
                   rules="all"
                   xml:id="table_TID_5204">
               <caption>Wall Motion Analysis</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_bb7bc341-f504-4c0a-92fe-c1d7aba5d572"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_40f6405d-fd6f-4742-a370-d59ade9ea308">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_78c53509-fbe7-4f32-a23b-a2bfd27ded54">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1de62684-26d8-4f86-8229-05568ff00d5c">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3ea8d09a-1f80-4331-ab37-3110c6b85efb">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1e3ad58c-585b-4172-821b-c8ce86dfbbda">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3c19545a-d377-4e14-bff6-c450951c2392">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_37ff5f39-6829-4c72-ae5e-877f8ca916ce">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f38437a4-f9d5-4f13-9ae5-ad53fd098d3c">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b9922827-b582-40cd-94cc-51847a920324">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b39c1979-2035-4e51-950b-f3b40c91773c">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bf47540f-5f34-46a6-b9ea-05650b327b0d">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8937232c-2fcb-4db5-8f79-52082b28a6b1">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2a2612ab-4065-432a-8630-50adbd6c648e">EV<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=363698007"
                                 xl:show="new">(G-C0E3, SRT, "Finding Site")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_209898d5-995a-4740-8094-d155463ddc83">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6cf532d1-9316-429c-8e89-9fbebc94deb7">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2dfce6ad-4135-4d14-b219-311db700c209"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7aa1813d-c064-4057-85ee-2df8be44cef4">DT<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=181293005"
                                 xl:show="new">(<emphasis role="bold">
                                 <emphasis role="strikethrough">T-D0772</emphasis>
                                 <emphasis role="underline">T-D075D</emphasis>
                              </emphasis>, SRT, "Myocardial Wall")</link>
                        </para>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>
         <section label="TID 5228" status="3" xml:id="sect_TID_5228">
            <title>Cardiac Ultrasound Fetal Measurement Section</title>
            <table frame="box"
                   label="TID 5228"
                   rules="all"
                   xml:id="table_TID_5228">
               <caption>Cardiac Ultrasound Fetal Measurement Section</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c34a294b-58d0-4d3e-90b1-015a24ca38dc"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_eb410b04-8582-46c4-93bf-402fcd5be677">
                           <emphasis role="bold">NL</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_de0aea54-7e8f-435b-9be9-8631072af1c0">
                           <emphasis role="bold">Rel with Parent</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_86b6cff5-ff5a-48c2-acb5-e4f5dd123491">
                           <emphasis role="bold">VT</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9f1e9566-c4a4-49bd-8aeb-21141c39f01e">
                           <emphasis role="bold">Concept Name</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ce154f27-b11a-4bc3-91b3-982262a994fb">
                           <emphasis role="bold">VM</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6213017b-b499-4746-9eb3-4d84463158cf">
                           <emphasis role="bold">Req Type</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_851c124e-408f-4fa8-87e7-e4c04cd1c348">
                           <emphasis role="bold">Condition</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3f6ba4d8-cbdb-403c-a9e8-e3e640bb2ff5">
                           <emphasis role="bold">Value Set Constraint</emphasis>
                        </para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f7d60650-c1d1-4eea-8cdc-f270817701d6">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b7968929-7df9-42d1-910f-83abba1378a3">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ae235c78-0a4b-4c4f-b92f-f5a8aa0f9c87">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f41fc287-e8ef-4e5c-90c6-a5ce99649053">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3c8869b0-c8af-49a6-9e4c-26f048ea4e6c">D<xref linkend="sect_TID_5222"
                                 xrefstyle="select: labelnumber quotedtitle nopage"/>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fe415629-9d1b-47c3-b63c-dc3e6383641f">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d2156da1-8121-4b8e-8f28-a0d2ac798feb">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f7d996e9-aa97-47fb-a3c1-1a361813fbe1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a942902e-32fa-426f-9b22-1122dd45ae52">$SectionSubject = EV<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=304829005"
                                 xl:show="new">(<emphasis role="bold">
                                 <emphasis role="strikethrough">T-F6806</emphasis>
                                 <emphasis role="underline">T-F680F</emphasis>
                              </emphasis>, SRT, "Ductus venosus")</link>
                        </para>
                        <para xml:id="para_8dfe5ae1-901e-472d-aeaf-7201056dc411">$MeasType = D<xref linkend="sect_CID_12218" xrefstyle="select: labelnumber quotedtitle"/>
                        </para>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>
      </section>
   </section>
    <section label="B" status="1" xml:id="chapter_B">
      <title>DCMR Context Groups (Normative)</title>
      <section label="CID 4" status="3" xml:id="sect_CID_4">
         <title>Anatomic Region</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_30a074f5-001c-4cd4-bdfb-99c1bc895a36">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_5cd1d4ea-2e1b-42f6-97f3-59d2eee62b95">
                     <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 4" rules="all" xml:id="table_CID_4">
            <caption>Anatomic Region</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_59fbe289-1928-49d3-a813-77261937f8f0">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f65e7b1e-09d3-424c-8dfd-7082798f52f8">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2383a167-6f66-4c47-a4dc-35097670ee35">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aa3445fc-b756-44fb-b905-bf333103cca7">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8efab2c8-389b-4d4e-8db5-376d64e216c2">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f529de2d-e960-4f33-8786-791a903c858d">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-AB000</emphasis>
                           <emphasis role="underline">T-AB001</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_bbd10bbd-e49d-4f5f-8fef-f6ff5521cf4a">Ear</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">1910005</emphasis>
                           <emphasis role="underline">117590005</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C0521421</emphasis>
                           <emphasis role="underline">C0013443</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9620c9eb-911a-48f3-802b-e8663155f54a">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-51000</emphasis>
                           <emphasis role="underline">T-D0662</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0ef13786-0adc-44d6-99b9-e617498a49ac">Mouth</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">21082005</emphasis>
                           <emphasis role="underline">123851003</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1267547</emphasis>
                           <emphasis role="underline">C0230028</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 645" status="3" xml:id="sect_CID_645">
         <title>Exogenous Substance Tissue of Origin</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_4f10a4e4-4018-4106-9d44-ec0d9aae3afa">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_8cbd2686-dca2-4a72-9515-79075407eff1">
                     <emphasis role="bold"><emphasis role="strikethrough">20151110</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 645" rules="all" xml:id="table_CID_645">
            <caption>Exogenous Substance Tissue of Origin</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0a5b90ed-da44-48f5-b9f0-e5a3cb270309">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_78d7a91c-1d46-4497-87c8-87aa6a0bb331">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_01226c00-b8c8-4b71-a4fe-7bfce3103a9d">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b6a56907-cd03-43f0-9415-750b3d668de1">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dac618a6-4c20-4968-b4c5-490f0ae20fa2">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6b0bafd8-bcf2-4abc-ad47-32068aad8adf">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-9200B</emphasis>
                           <emphasis role="underline">T-92000</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_cc5d0f84-952e-4f5f-8ff2-3f335394f7e6">Prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181422007</emphasis>
                           <emphasis role="underline">41216001</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1278980</emphasis>
                           <emphasis role="underline">C0033572</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 3010" status="3" xml:id="sect_CID_3010">
         <title>Cardiovascular Anatomic Locations</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_aec42c1d-7a3f-4dca-90a0-7d3c9ea40ddb">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_03b70559-3985-4c9b-a232-5247ed211c84">
                     <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 3010"
                rules="all"
                xml:id="table_CID_3010">
            <caption>Cardiovascular Anatomic Locations</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6fe005f7-cbb0-4f3b-9b8a-52b94ca3f2a6">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_13c38c86-b956-4265-a92c-61770a64b4b5">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f26825ee-7377-4af2-a163-961cf428414f">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ed29c4cd-7587-4252-bdeb-12a4476839dd">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aee07496-af06-4ddf-8e09-cfbeeebd382f">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_26d8e9d6-2092-4053-9916-696317ba1e54">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-48440</emphasis>
                           <emphasis role="underline">T-48403</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a515b5a7-3232-4db0-af5c-944c8c9efc6c">Anterior cardiac vein</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">43967001</emphasis>
                           <emphasis role="underline">194996006</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1267461</emphasis>
                           <emphasis role="underline">C0226662</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c099e33c-9a65-4c7f-96ea-1130ab425858">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-48470</emphasis>
                           <emphasis role="underline">T-484A4</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_21ccb93e-8b6c-47df-a04c-0c79a1dfc291">Inferior cardiac vein</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">60477001</emphasis>
                           <emphasis role="underline">195416006</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1267462</emphasis>
                           <emphasis role="underline">C0226664</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7267bf04-9151-4889-b69e-2b7ead34c3f6">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-48817</emphasis>
                           <emphasis role="underline">T-48832</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fceb8077-23c9-4331-9b62-6d34a2585cca">Umbilical vein</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">61660003</emphasis>
                           <emphasis role="underline">284639000</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1267489</emphasis>
                           <emphasis role="underline">C0226734</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 3440" status="3" xml:id="sect_CID_3440">
         <title>Peripheral Pulse Locations</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_dd96dd0d-c5c2-4483-ad76-d59c862fe1d9">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_252ee165-fc51-494e-8344-a9b1e2d78f1f">
                     <emphasis role="bold">20030327</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 3440"
                rules="all"
                xml:id="table_CID_3440">
            <caption>Peripheral Pulse Locations</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0d379a0f-db2a-4878-8b05-9942918cc521">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b0c54f3-8c9e-4545-bb27-fb797a27ac7d">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6b701b77-96fa-40e7-a240-624342a79f16">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cc44ccb9-7a56-456e-9f2e-13d21fc17ef6">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4bf5ba8c-a438-4f60-878e-51cff93d633b">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2b48d462-bc4d-490a-9dc1-6b940f8042a8">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-47741</emphasis>
                           <emphasis role="underline">T-47740</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_13b14c68-7b46-436b-b9d3-2262d5ca34ba">Dorsalis Pedis Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181362007</emphasis>
                           <emphasis role="underline">86547008</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1269022</emphasis>
                           <emphasis role="underline">C0226492</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 3606" status="3" xml:id="sect_CID_3606">
         <title>Arterial Source Locations</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_89cb619a-66d7-4bdb-aa46-ea79526c2c00">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_59114638-6473-4fe8-88fb-dec90ff81c43">
                     <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 3606"
                rules="all"
                xml:id="table_CID_3606">
            <caption>Arterial Source Locations</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_972df53d-3bcf-445e-a1f3-5a76d965fbea">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_74e2b166-8882-4f12-8f47-e2e2d507bbda">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2de0ab97-8bb3-4bba-bd13-2d15d72a7a90">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4b8c4233-5bad-4322-a016-0f5916537b1e">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5e9d130a-5f50-461b-8115-1937b8329bcb">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aaaa055e-c3ed-42d8-a711-2fe0871e07a4">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-47651</emphasis>
                           <emphasis role="underline">T-47650</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a7331e67-3f95-47d4-b203-93e7865fd01e">lateral plantar artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181361000</emphasis>
                           <emphasis role="underline">44830000</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1278959</emphasis>
                           <emphasis role="underline">C0226478</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2c483edf-3d92-4e7a-8d11-81deabbf95a9">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-47661</emphasis>
                           <emphasis role="underline">T-47660</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5a0736de-6130-4858-b169-10b9eed2557f">medial plantar artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181360004</emphasis>
                           <emphasis role="underline">74156002</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1278958</emphasis>
                           <emphasis role="underline">C0226479</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 3607" status="3" xml:id="sect_CID_3607">
         <title>Venous Source Locations</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_3f4dabe8-627c-4498-a65b-d62e7dc5aafd">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f8e90d7e-7fb3-4df8-bdd8-65dd80efc90e">
                     <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 3607"
                rules="all"
                xml:id="table_CID_3607">
            <caption>Venous Source Locations</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6f830304-7e9f-4cde-a6c5-b1178be71f34">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b364ffca-e866-4a3c-924d-c8ce9fd4ffeb">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_96729c64-4fb9-443f-9a39-164f3aeae315">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_953cc0ca-9070-427e-8993-6f6f79123c6c">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_837786c9-dd1d-40a7-9ad5-dd11ccb9e03b">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ec2bc204-155d-4494-9bea-27433d39372d">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-48817</emphasis>
                           <emphasis role="underline">T-48832</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8edf4eb9-0f9a-489e-92c8-319ba6429aca">Umbilical vein</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">61660003</emphasis>
                           <emphasis role="underline">284639000</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1267489</emphasis>
                           <emphasis role="underline">C0226734</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 4030" status="3" xml:id="sect_CID_4030">
         <title>CT, MR and PET Anatomy Imaged</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_c48fdbda-f6dc-4a1d-9824-99d5a5064236">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_0523ad91-1f57-44c7-8ce7-3533ebd9d7cd">
                     <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 4030"
                rules="all"
                xml:id="table_CID_4030">
            <caption>CT, MR and PET Anatomy Imaged</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ca6afd3c-3f1e-44ca-acf0-27454a3249b8">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f3b00367-aa05-4d33-bea4-0014a10eae72">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_586516cd-b177-4151-bb23-bd178643d768">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ad1dad1-40d1-4ccc-a24f-dceeec147dcf">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_34c6028c-cf63-4ed7-adb9-f21cf268d9e4">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f7906d0f-683e-4730-b5d6-4d4701c59e3b">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-45526</emphasis>
                           <emphasis role="underline">T-45520</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_06a3ed04-16aa-473b-9f01-b240b9f51d54">Circle of Willis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">362047009</emphasis>
                           <emphasis role="underline">11279006</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1284333</emphasis>
                           <emphasis role="underline">C0008812</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_019313a4-ffcd-4d61-b7b8-bdf85511f2ed">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-A0193</emphasis>
                           <emphasis role="underline">T-15516</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_2240b565-05c9-4664-9d5d-783f4c1b0050">Cranial venous system</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">244391007</emphasis>
                           <emphasis role="underline">125682004</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1280180</emphasis>
                           <emphasis role="underline">C0016125</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 4031" status="3" xml:id="sect_CID_4031">
         <title>Common Anatomic Regions</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_add43dab-8514-43e5-a45b-9b57022e3b84">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_ff02f786-0f11-46df-a874-f0f4a77597ab">
                     <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 4031"
                rules="all"
                xml:id="table_CID_4031">
            <caption>Common Anatomic Regions</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f80f07fc-1abf-4732-a05e-eaf50b9f1cd4">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bb71cd6d-14c5-4693-89f7-445e42dae823">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_74b6d43d-73a0-4bad-b800-374dffd8f58e">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f5eeb80e-b1de-48f1-bd9e-757f4532f9e4">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f3f4f8f1-4a1d-4ef1-b81c-a3932027d569">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f7eda5e7-e7c9-4f70-89dd-c79ea95f6be8">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-9200B</emphasis>
                           <emphasis role="underline">T-92000</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9368ad26-babd-4184-97a2-87669e511b32">Prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181422007</emphasis>
                           <emphasis role="underline">41216001</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1278980</emphasis>
                           <emphasis role="underline">C0033572</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 4266" status="3" xml:id="sect_CID_4266">
         <title>Ophthalmic Anatomic Structure Reference Point</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f41e959c-7aac-49b7-afdc-4bc2be14fc78">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_a5e0c29d-addc-4d2e-a6f7-156781f43fd5">
                     <emphasis role="bold"><emphasis role="strikethrough">20131014</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 4266"
                rules="all"
                xml:id="table_CID_4266">
            <caption>Ophthalmic Anatomic Structure Reference Point</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c6b66717-a71d-4f79-96ce-987eb8cba99c">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_35a80173-0e9d-4af3-850a-b6d30744e1dd">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0c20f880-0543-4db1-8919-cc1abc5624ec">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_be3f4cb4-d6db-45d3-b34c-167a8b8e65bf">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ebfff4d-fdf0-4f59-b9c7-7e3ce2667ed4">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1f8ec52a-c212-4f3c-a77f-0de17ff8ed56">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-AA215</emphasis>
                           <emphasis role="underline">T-AA200</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_257274b2-1d6e-4109-bf25-f1f445084b96"><emphasis role="bold"><emphasis role="strikethrough">Entire</emphasis></emphasis> Cornea</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181162001</emphasis>
                           <emphasis role="underline">28726007</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1278889</emphasis>
                           <emphasis role="underline">C0010031</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 6015" status="3" xml:id="sect_CID_6015">
         <title>Single Image Finding from BI-RADS®</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_518f9e0e-23e6-483e-a1ef-7c32f1536fd2">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_16e4036d-0210-47a5-91a0-90a504b45f91">
                     <emphasis role="bold"><emphasis role="strikethrough">20150106</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 6015"
                rules="all"
                xml:id="table_CID_6015">
            <caption>Single Image Finding from BI-RADS®</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_baa33ce6-6ac3-491e-8658-b75fff0ea745">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5b3e6fdb-f576-482f-96d9-ca26118a5b05">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_29403c86-6dba-4ec7-9bfc-98242604ab46">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5ab763db-e72e-44c5-b24b-09f8c1f2972f">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ef95cbe2-6a4f-4c0a-9ddb-5011884b0a20">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_db582c59-902d-492c-9282-a98e86f8fbe5">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-C4351</emphasis>
                           <emphasis role="underline">T-C430B</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c822c3e1-80d3-45b3-b292-f885d8e5e1ba">Intra-mammary lymph node</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">421997006</emphasis>
                           <emphasis role="underline">443808008</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1706372</emphasis>
                           <emphasis role="underline">C2733350</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 6031" status="3" xml:id="sect_CID_6031">
         <title>Benign Pathology Codes from BI-RADS®</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f1b45b0f-85c3-42e9-8b51-7a8356a8bdf0">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_6a94c1aa-ac49-4b32-bf8d-6be23cef18b8">
                     <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 6031"
                rules="all"
                xml:id="table_CID_6031">
            <caption>Benign Pathology Codes from BI-RADS®</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1803fe3c-e056-421c-957f-342efa764ec2">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b62ba875-218c-4fb4-8ffd-8783dca4b469">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f7ffbc68-6703-42ed-bb6b-443a31ebd759">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9a11e486-f65e-4c88-a347-0e5c6a151cfd">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0d7b1e5f-d2be-4730-b3ab-57aaf5928db0">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_12d3d2f1-4fce-4493-8ab4-d7dfc8017cb3">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                           <emphasis role="bold">
                              <emphasis role="strikethrough">T-C4351</emphasis>
                              <emphasis role="underline">T-C430B</emphasis>
                           </emphasis>
                        </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_749e9430-16eb-4c0f-8999-1e916336f223">Intra-mammary lymph node</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                           <emphasis role="bold">
                              <emphasis role="strikethrough">421997006</emphasis>
                              <emphasis role="underline">443808008</emphasis>
                           </emphasis>
                        </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                           <emphasis role="bold">
                              <emphasis role="strikethrough">C1706372</emphasis>
                              <emphasis role="underline">C2733350</emphasis>
                           </emphasis>
                        </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 6114" status="3" xml:id="sect_CID_6114">
         <title>Osseous Anatomy Finding or Feature</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_53842f80-b72e-406d-8787-866eee82f2f5">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_eecde353-d17b-499a-9b4d-e377a85f8ff2">
                     <emphasis role="bold">20030108</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 6114"
                rules="all"
                xml:id="table_CID_6114">
            <caption>Osseous Anatomy Finding or Feature</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3115032b-2853-4cfe-9a17-6f65db744f60">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_99f9dd60-c5f3-4585-a622-55d797cc4375">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2fc7889d-db48-45e6-9654-748f40a6b419">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3509e26e-3c1c-4781-b08e-0ad630d5c25a">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_205c541c-65bc-4f14-9474-8772d79e466d">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf99ec16-e19a-431e-bc97-ba6fe8af0f7d">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-11500</emphasis>
                           <emphasis role="underline">T-D04FF</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4a0195bf-a763-4db9-8dea-37f8b0c96842">Spine</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">44300000</emphasis>
                           <emphasis role="underline">421060004</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1267072</emphasis>
                           <emphasis role="underline">C0037949</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 6116" status="3" xml:id="sect_CID_6116">
         <title>Muscular Anatomy</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_e9f22525-f03f-44ea-824c-282b0923f217">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_7680ee4c-6e43-4257-b8b0-3517a9ee4cd7">
                     <emphasis role="bold"><emphasis role="strikethrough">20130617</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 6116"
                rules="all"
                xml:id="table_CID_6116">
            <caption>Muscular Anatomy</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_488f6ad4-d997-451e-acec-6b2325243737">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_87d60a90-acde-4548-b776-b3ac6f198168">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6439ea2a-93f2-49e9-9c40-84092eabf5d3">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_957e58e1-1313-4aef-8dd9-57575b2daecf">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b49cd966-6b0b-4bfb-ad16-00fb2a876206">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_784b79d2-ff33-418b-8b57-7dff83bb78d7">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-1416B</emphasis>
                           <emphasis role="underline">T-A0191</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c7925ef2-d9ba-49ca-8411-daef9eaf9811">External intercostal muscle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">244878003</emphasis>
                           <emphasis role="underline">128320002</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1744535</emphasis>
                           <emphasis role="underline">C0447118</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e9ea990f-5ee1-44bb-8254-1e5972d5815a">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-14183</emphasis>
                           <emphasis role="underline">T-14161</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_57b0f855-aaea-4374-b79c-e6616b6d0126">Internal intercostal muscle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">244890001</emphasis>
                           <emphasis role="underline">53967007</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1744536</emphasis>
                           <emphasis role="underline">C1744535</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1b38fb8e-2ea3-4bb4-9b2c-1bd85ad04cfb">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-141A5</emphasis>
                           <emphasis role="underline">T-14163</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e93167e4-9566-471c-bf82-ea69d26f71a7">Transversus thoracis</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">244933000</emphasis>
                           <emphasis role="underline">41313007</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1744608</emphasis>
                           <emphasis role="underline">C1744536</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 7140" status="3" xml:id="sect_CID_7140">
         <title>Brain Structures for Volumetric Measurements</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_36face7e-90ba-4f81-96aa-3f47b61beacf">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_c5b7521c-60da-4fbc-90cb-1fb33c9c889b">
                     <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 7140"
                rules="all"
                xml:id="table_CID_7140">
            <caption>Brain Structures for Volumetric Measurements</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a93c208d-fd67-45e6-870d-0aed1cf6bedb">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b4ebe3f5-e6c7-413e-8a74-95570474bac7">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1815e54e-5184-41bc-8359-11e5aca2265c">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9d74c8e3-37c2-412d-967b-183ded65693f">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7577d7b9-54fb-4416-8bda-786f0b36d7f6">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ff72f873-9e52-434f-8037-4faa69ad56b7">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-A6041</emphasis>
                           <emphasis role="underline">T-A6040</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ec307cb7-fff3-405b-8ec9-3836e0e088ab">Cerebellar Cortex</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">361593004</emphasis>
                           <emphasis role="underline">25991003</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1284087</emphasis>
                           <emphasis role="underline">C0007759</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_19cd0c70-c00a-4921-a9b1-7693e1408740">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-D1403</emphasis>
                           <emphasis role="underline">T-14167</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_54aab7fd-0d81-4cab-9ca0-d6cc6114fed2">Cranial Cavity</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">264452006</emphasis>
                           <emphasis role="underline">88454005</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1280705</emphasis>
                           <emphasis role="underline">C1744608</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_407019ce-e8a8-4bbd-a3ce-4abb84cfcec6">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-A1721</emphasis>
                           <emphasis role="underline">T-A1720</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_791240fa-c229-4425-b76d-8c20da6d0b76">Inferior Horn of Lateral Ventricle</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">362315005</emphasis>
                           <emphasis role="underline">53118009</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1284574</emphasis>
                           <emphasis role="underline">C0152283</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
         <note>
            <orderedlist numeration="arabic">
               <listitem>
                  <para xml:id="para_f3927fab-3f9c-4244-8c97-ce7bae2f1b6e">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=264452006" xl:show="new">(<emphasis role="bold">
                              <emphasis role="strikethrough">T-D1403</emphasis>
                              <emphasis role="underline">T-14167</emphasis>
                           </emphasis>, SRT, "Cranial Cavity")</link>may be used to describe the volume of the entire intra-cranial space (intra-cranial volume or ICV)<emphasis role="bold"><emphasis role="underline">, though the coded concept used is "structure of" rather than "entire" to be consistent with normal DICOM practice</emphasis></emphasis>.</para>
               </listitem>
               <listitem>
                  <para xml:id="para_1930387d-5602-4844-8a20-3fa24e7bdfd7">
                     <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=361593004"
                           xl:show="new">(<emphasis role="bold">
                           <emphasis role="strikethrough">T-A6041</emphasis>
                           <emphasis role="underline">T-A6040</emphasis>
                        </emphasis>, SRT, "Cerebellar Cortex")</link>is the gray matter of the cerebellum (as distinct from<link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=33060004"
                           xl:show="new">(T-A6080, SRT, "Cerebellar white matter")</link>).</para>
               </listitem>
               <listitem>
                  <para xml:id="para_557ae3cc-ad54-410a-892f-b3f4498c8fab">
                     <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=33930006"
                           xl:show="new">(T-A1502, SRT, "Cranial Subarachnoid Space")</link>may be used to describe the volume of the exterior CSF (surrounding the brain, excluding the ventricles).</para>
               </listitem>
               <listitem>
                  <para xml:id="para_8f75c726-2b21-46f6-a9f0-1184cd970ef6">
                     <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=263972004"
                           xl:show="new">(T-A1509, SRT, "Cerebellar Subarachnoid Space")</link>may be used to describe the volume of the inferior intracranial CSF space (infra-tentorial).</para>
               </listitem>
            </orderedlist>
         </note>
      </section>
      <section label="CID 7304" status="3" xml:id="sect_CID_7304">
         <title>Implant Target Anatomy</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_382363f1-5d12-47dd-9c61-fbfd132660cc">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_fb1f46cf-48fb-4320-a4a1-1ab3fd55812e">
                     <emphasis role="bold"><emphasis role="strikethrough">20130617</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 7304"
                rules="all"
                xml:id="table_CID_7304">
            <caption>Implant Target Anatomy</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_56ea47f6-defe-4322-8e53-ae3cb0608df6">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9865abc3-0a2e-4ae6-89bf-aa182885eadc">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d6256ba8-fb86-47bc-b8be-e5eb10b16781">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0ef7896b-b1da-4c81-b84e-c480746596ff">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1ab1b004-d618-415c-8698-b2f0eb58abfe">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6a3abfdd-7cb7-4464-a15e-59a9734231fa">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-1553D</emphasis>
                           <emphasis role="underline">T-1278B</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d623fc87-f41b-4bd4-b7ba-62b02c359c14">Finger Joint</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">182189009</emphasis>
                           <emphasis role="underline">244669006</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1279142</emphasis>
                           <emphasis role="underline">C0444442</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 7483" status="3" xml:id="sect_CID_7483">
         <title>Common Anatomic Regions for Animals</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_17a15ef9-cbab-43fd-8bf6-003b54510e2d">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_cfd94de1-951c-4dce-94da-a237bbf4b302">
                     <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 7483"
                rules="all"
                xml:id="table_CID_7483">
            <caption>Common Anatomic Regions for Animals</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4d8e83b5-c027-418c-8ace-828157d87236">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fc6fdd5b-dacd-4e69-9443-035897f3ef2b">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b952f1ad-534a-415b-ac3b-6c2795fcc70e">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8deda82f-f69b-484d-bf54-7b0b68950675">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6a60837d-df09-4056-a177-de16e36de9fc">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_177769c9-7e6f-4847-9a70-1e7a8bff3cdf">
                        <emphasis role="bold">Notes</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_44ceb6b9-7651-4a33-8e68-98778ee322f2">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-1531B</emphasis>
                           <emphasis role="underline">T-15317</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e0c38c8c-1bb0-4d03-8b4c-0dc532a8a3fa">Atlantal-axial joint</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">361832004</emphasis>
                           <emphasis role="underline">62555009</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1284202</emphasis>
                           <emphasis role="underline">C0224585</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td>
                     <para xml:id="para_e2829127-8632-4c25-9008-9391553bc10f"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8736c98c-4f30-412b-80ee-73669591e72c">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-11B02</emphasis>
                           <emphasis role="underline">T-11B00</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_45e2b6c5-6f47-4f4a-a012-8be866a053b6">Coccygeal vertrebrae</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">361774004</emphasis>
                           <emphasis role="underline">18149002</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1305250</emphasis>
                           <emphasis role="underline">C0223616</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_36f4292f-c13f-46b2-b3ee-c20fce74192c">See Note 3.</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2b3bc2a5-f36e-4365-9da3-3aed249fe79a">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-110A2</emphasis>
                           <emphasis role="underline">T-35310</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a5a2b1a8-5c22-436e-90cf-086c8ab53df8">Distal phalanx</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">299711006</emphasis>
                           <emphasis role="underline">65197004</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C0576464</emphasis>
                           <emphasis role="underline">C0225947</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td>
                     <para xml:id="para_d5e266a9-c299-436f-954e-593dd96cd821"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3322949e-ed1d-4206-83e0-c9401dd238b4">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-1254D</emphasis>
                           <emphasis role="underline">T-12540</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7a9b405b-aaf2-414b-84ed-25e60617b88e">Metacarpus</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181977005</emphasis>
                           <emphasis role="underline">36455000</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1269064</emphasis>
                           <emphasis role="underline">C0025526</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td>
                     <para xml:id="para_b2ee6ac2-b85e-49b2-a904-3a486f7e6da8"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b50410f5-fffa-45df-90ba-1838a583e717">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-127EC</emphasis>
                           <emphasis role="underline">T-12800</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4cce826d-528d-43a2-a414-ced1fd12df42">Navicular of hindfoot</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">182100005</emphasis>
                           <emphasis role="underline">75772009</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1306480</emphasis>
                           <emphasis role="underline">C0223947</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4bb18902-c538-4343-9e2d-3344f2bab7e8">See Note 4.</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d1826e53-5150-42ac-8f25-ade2e9879884">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-D14AD</emphasis>
                           <emphasis role="underline">T-D08CA</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0d5e204f-f9e9-4ff4-b97d-aca56f741dff">Orbital region</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181143004</emphasis>
                           <emphasis role="underline">714483002</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1278884</emphasis>
                           <emphasis role="underline">C0700042</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td>
                     <para xml:id="para_222de1dd-2d89-4041-b51e-35eaa99124d0"/>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 10044" status="3" xml:id="sect_CID_10044">
         <title>Radiosensitive Organs</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_b494337d-1d52-4f58-89b0-697a9e12e729">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f21609f1-5197-4216-8269-ff4e5d07044b">
                     <emphasis role="bold"><emphasis role="strikethrough">20140419</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 10044"
                rules="all"
                xml:id="table_CID_10044">
            <caption>Radiosensitive Organs</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1165a97a-979b-4baf-a26a-f45b3e2b9181">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6a5a49a6-b8a5-48e3-94b1-d482a17d54d7">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bb3abdc2-bc50-45b3-8d08-c7a20b550fc4">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4203eac1-1fc1-490b-9be2-41f247f044c7">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fc0c274c-26b2-4e08-a902-3a7252a0f134">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fb5b35bc-9133-45ca-8d9b-938b80a0a556">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-62002</emphasis>
                           <emphasis role="underline">T-62000</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_346d3496-3abc-4b2c-891c-4538d8130ed0">Liver</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181268008</emphasis>
                           <emphasis role="underline">10200004</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1278929</emphasis>
                           <emphasis role="underline">C0023884</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_24981a4d-d4e6-481d-b83b-e48efc477592">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-9200B</emphasis>
                           <emphasis role="underline">T-92000</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6873dd5a-9cdb-452a-89cc-f9d4e6b45e6f">Prostate</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181422007</emphasis>
                           <emphasis role="underline">41216001</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1278980</emphasis>
                           <emphasis role="underline">C0033572</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c583da67-5287-49d8-871e-f4754a5a5438">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-00009</emphasis>
                           <emphasis role="underline">T-01000</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_8fbee84b-0cc3-42d0-8154-0f1e603a83c8">Skin</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181469002</emphasis>
                           <emphasis role="underline">39937001</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1278993</emphasis>
                           <emphasis role="underline">C1123023</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 12109" status="3" xml:id="sect_CID_12109">
         <title>Lower Extremity Arteries</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_2f55af78-9e80-4653-a2ad-6bdad182ebe3">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_22c03cc6-1815-49c0-bfc2-05b468397af7">
                     <emphasis role="bold">20050110</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 12109"
                rules="all"
                xml:id="table_CID_12109">
            <caption>Lower Extremity Arteries</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b985ff8e-1208-471a-8f75-c514155a6033">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4cf6a957-a41b-4665-90cc-4ab7c476a587">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_15726517-44c0-4951-be41-21bdb168984a">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9211f8c5-b27d-4aed-8229-1f43c6c18abb">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_13f90a44-4531-4142-8ab2-5abaa74185c3">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c05853eb-2406-4aa3-a59e-bb7da40819ac">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-47741</emphasis>
                           <emphasis role="underline">T-47740</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c8ff6144-8a80-4d6d-95bb-781b766cd8af">Dorsalis Pedis Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">181362007</emphasis>
                           <emphasis role="underline">86547008</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1269022</emphasis>
                           <emphasis role="underline">C0226492</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 12114" status="3" xml:id="sect_CID_12114">
         <title>Abdominal Veins (Unilateral)</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_d3f9ec9a-7f07-413b-b3bc-776201c2136a">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_6eb16b07-d98b-4159-ad26-fc8f90546b7d">
                     <emphasis role="bold">20030327</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 12114"
                rules="all"
                xml:id="table_CID_12114">
            <caption>Abdominal Veins (Unilateral)</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_923d0728-b47e-4576-9c84-68c90f87233d">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8a0be2a7-7a90-4c2e-a588-76ffd246ddf2">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a6fd3f02-3763-4f43-a2aa-75b17d942181">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_44f317b6-061b-4f14-b4db-570c145899f7">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_082aa6dd-d5b5-42c0-95f9-cc2a54749f76">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_4839af83-eb91-44fd-94a5-59c8f0fecceb">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-4881F</emphasis>
                           <emphasis role="underline">T-48814</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_785d4070-4820-4175-b5db-65eb22d7cad9">Left Main Branch of Portal Vein</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">304374005</emphasis>
                           <emphasis role="underline">70253006</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3fda00b5-e836-4e65-8d7f-1f44d133faa7"><emphasis role="bold"><emphasis role="strikethrough">C0582255</emphasis><emphasis role="underline">C0933785</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_693c1ad9-fe25-4f1e-b578-677f3cb0a92c">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-4882A</emphasis>
                           <emphasis role="underline">T-48813</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_4de00087-a9f3-4544-beb6-af2b200db38e">Right Main Branch of Portal Vein</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">304375006</emphasis>
                           <emphasis role="underline">73931004</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C0582256</emphasis>
                           <emphasis role="underline">C0226730</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0e98a478-1488-41d2-a679-967f82226341">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-48817</emphasis>
                           <emphasis role="underline">T-48832</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c4a59fc9-e322-4839-91d0-882637bffd4f">Umbilical Vein</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">61660003</emphasis>
                           <emphasis role="underline">284639000</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1267489</emphasis>
                           <emphasis role="underline">C0226734</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 12235" status="3" xml:id="sect_CID_12235">
         <title>Mitral Valve Anatomic Sites</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_a97457a3-50a8-4e1a-8ed2-6b58f0712a7f">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_355a5a23-51af-48b3-8623-a050f7811e5e">
                     <emphasis role="bold">20040614</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 12235"
                rules="all"
                xml:id="table_CID_12235">
            <caption>Mitral Valve Anatomic Sites</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8f43d593-e355-413f-86ec-295cd0754098">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_158b053e-6968-41b5-9a5b-bac3184a3a15">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6386c897-b3fe-4081-b846-2e2d2366f388">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5c326e88-9772-4fce-ae45-3817afde557f">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bb58fe96-1a0e-4aed-864a-37b59e656b58">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9cc65d9c-eb32-4ee7-8164-a827c8d2c8ba">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-35313</emphasis>
                           <emphasis role="underline">T-35110</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_278e7689-1670-403e-87b9-5ffc7b0c2a33">Mitral Annulus</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">279174006</emphasis>
                           <emphasis role="underline">113259005</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1305163</emphasis>
                           <emphasis role="underline">C0225926</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 12241" status="3" xml:id="sect_CID_12241">
         <title>Tricuspid Valve Finding Sites</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_990ee88c-f250-48ef-93fe-61276ca6deae">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f4447390-3833-4084-9ba6-cc234cb13668">
                     <emphasis role="bold">20040614</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 12241"
                rules="all"
                xml:id="table_CID_12241">
            <caption>Tricuspid Valve Finding Sites</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fd283ba4-bcae-422c-9c5b-f0079df73dda">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_17151640-75e9-46e1-9335-9711c286dcd4">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_49e85d71-2d8a-41f2-96dc-e0a141dc762b">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b91ac94-8493-4cb9-b524-bd364e949474">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_20838e6b-591b-44d9-823e-29ebda41f454">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d561236b-736a-465a-8a1e-1fb059163d83">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-35111</emphasis>
                           <emphasis role="underline">T-42230</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9ef9d14d-ed6c-4413-a475-424a9b2966c9">Tricuspid Annulus</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">279170002</emphasis>
                           <emphasis role="underline">24865005</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C1305155</emphasis>
                           <emphasis role="underline">C0226018</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 12291" status="3" xml:id="sect_CID_12291">
         <title>Cardiac Ultrasound Aorta Finding Sites</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_83f1b82f-1838-4625-ae32-04226ec1cc30">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_849b539d-98a7-44d0-887d-b680beff77a3">
                     <emphasis role="bold"><emphasis role="strikethrough">20100317</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 12291"
                rules="all"
                xml:id="table_CID_12291">
            <caption>Cardiac Ultrasound Aorta Finding Sites</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7e501c31-f15b-4b75-b118-2fd80870a705">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f4b72d35-b97c-4b86-86ce-6988ba5e47c0">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2197b237-cc47-4c69-b06f-16573de65b28">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_239d9ebf-1c38-4566-ad6b-1c1f2465eb9e">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1703e5c3-06f9-4130-a4af-1247256d98e2">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_aea170f8-e4ee-45dd-8d2f-db58abe5bba3">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-42231</emphasis>
                           <emphasis role="underline">T-D1400</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e3bace36-e62c-494f-b7c4-3a8a3f14c58e">Non-coronary Sinus</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">264873000</emphasis>
                           <emphasis role="underline">1101003</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C0445122</emphasis>
                           <emphasis role="underline">C0230041</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
      <section label="CID 12292" status="3" xml:id="sect_CID_12292">
         <title>Cardiac Ultrasound Coronary Arteries Finding Sites</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_9c2182ba-1087-4089-9787-1019dedbe8d5">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_dee2e9f1-aa49-413a-804b-75d8be15f970">
                     <emphasis role="bold"><emphasis role="strikethrough">20100317</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box"
                label="CID 12292"
                rules="all"
                xml:id="table_CID_12292">
            <caption>Cardiac Ultrasound Coronary Arteries Finding Sites</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bf0b688d-bf81-49a6-a939-7028fea61e78">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b7824a90-3d65-45b3-8cda-b6eab24ae0a8">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8af38b2a-d439-4e41-bc7c-b16fbef05878">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_33b69be7-fe54-4b82-95f5-952de517a4b2">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_11e05782-20f6-45d6-b9d8-7be45adb766c">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_90666433-6ba2-4c46-b5bb-f8fc69ab2aa6">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">T-43203</emphasis>
                           <emphasis role="underline">T-43200</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b3214e22-a2d6-4d49-be91-82a532710bf2">Right Coronary Artery</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">362037006</emphasis>
                           <emphasis role="underline">13647002</emphasis>
                        </emphasis>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <emphasis role="bold">
                           <emphasis role="strikethrough">C0226042</emphasis>
                           <emphasis role="underline">C1261316</emphasis>
                        </emphasis>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
   </section>
     
     <section label="E" status="1" xml:id="chapter_E">
        <title>French Language Meanings of Selected Codes Used in the DCMR (Normative)</title>
        <table frame="box" label="E-1" rules="all" xml:id="table_E-1">
           <caption>French Language Meanings of Selected Codes</caption>
           <thead>
              <tr valign="top">
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_090f9188-a249-49a9-82d7-0a9851688cea">
                       <emphasis role="bold">Coding Scheme Designator</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_238a2497-22be-41cd-af6f-3df3a3689ee9">
                       <emphasis role="bold">Coding Scheme Version</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_0467362d-e7f7-4d4d-a1aa-8a096bbb1a7b">
                       <emphasis role="bold">Code Value</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_b2226261-7655-49c3-a0bc-c0295572a723">
                       <emphasis role="bold">Code Meaning English Language</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_036bfbde-f73b-46a0-883b-c655056c459f">
                       <emphasis role="bold">Code Meaning French Language</emphasis>
                    </para>
                 </th>
              </tr>
           </thead>
           <tbody>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para xml:id="para_02675043-4897-40f1-8bb4-8b3b5ce163aa">SRT</para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                    <para xml:id="para_62e4952e-2fc1-4d0a-a134-c4dd3990aaff"/>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                    <para xml:id="para_f4ab7b0a-fa70-472f-a9c8-b5dd25578748"><emphasis role="bold"><emphasis role="strikethrough">T-C4351</emphasis><emphasis role="underline">T-C430B</emphasis></emphasis></para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_7503ec08-d051-49ef-902a-d79cfeeaa9ee">Intra-mammary lymph node</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_14b7a65c-ce4b-4c7c-a94f-7743c542e745" xml:lang="fr">Ganglion intramammaire</para>
                 </td>
              </tr>
           </tbody>
        </table>
     </section>
     
     <section label="F" status="1" xml:id="chapter_F">
        <title>Japanese Language Meanings of Selected Codes Used in The DCMR (Normative)</title>
        <table frame="box" label="F-1" rules="all" xml:id="table_F-1">
           <caption>Japanese Language Meanings of Selected Codes</caption>
           <thead>
              <tr valign="top">
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_0a2ebcad-b99b-4ed7-abb6-1044db248781">
                       <emphasis role="bold">Coding Scheme Designator</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_72126191-efa7-4aef-81a7-3e4ab94ce310">
                       <emphasis role="bold">Coding Scheme Version</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_d41965ca-6e67-4f76-80aa-514d54300e66">
                       <emphasis role="bold">Code Value</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_799e56ce-9686-474e-98c4-b95f6d408b86">
                       <emphasis role="bold">Code Meaning English Language</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_ed2ca850-ba13-4e52-b40a-dc809e58b83f">
                       <emphasis role="bold">Code Meaning Japanese Language</emphasis>
                    </para>
                 </th>
              </tr>
           </thead>
           <tbody>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para xml:id="para_6b799eeb-532b-4b42-a23d-528c5140f96a">SRT</para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                    <para xml:id="para_7547c3af-8217-4ea1-b176-e80319335b37"/>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                    <para xml:id="para_dd910049-70e0-48db-8228-d06b7bbf6136"><emphasis role="bold"><emphasis role="strikethrough">T-C4351</emphasis><emphasis role="underline">T-C430B</emphasis></emphasis></para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_41993b3b-a849-4ee7-978d-12adb1134f99">Intra-mammary lymph node</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_1f4ead6d-eaec-4e3a-9850-ffbe80dc991f" xml:lang="ja">乳房内リンパ節</para>
                 </td>
              </tr>           </tbody>
        </table>
     </section>

    <section label="J" status="1" xml:id="chapter_J">
      <title>SNOMED Retired Codes</title>
      <table frame="box" label="J-1" rules="all" xml:id="table_J-1">
        <caption>SNOMED Codes Retired from DICOM Use</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_ba15f948-561c-4cf6-a7c8-451b15b4d601">
                <emphasis role="bold">Retired Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_64a0b043-59fc-410d-a39e-81671a662f04">
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_a1e2c06a-1e64-4fd5-9ffb-0da12a76aeb2">
                <emphasis role="bold">Replacement Code</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_246a7171-2a92-45ac-80b1-7ed33ffc877b">
                <emphasis role="bold">Notes</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-48440</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Anterior cardiac vein</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-48403</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of anterior cardiac vein (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-1531B</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Atlantal-axial joint</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-15317</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of atlantoaxial joint (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-40501</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Blood Vessel of Head</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-D0767</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Vascular structure of head (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-A6041</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Cerebellar Cortex</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-A6040</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Cerebellar cortex structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-45526</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Circle of Willis</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-45520</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of circle of Willis (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-11B02</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Coccygeal vertrebrae</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-11B00</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Coccygeal vertebra structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-D1403</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Cranial Cavity</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-14167</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of transverse thoracis muscle (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-A0193</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Cranial venous system</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-15516</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Finger joint structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-110A2</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Distal phalanx</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-35310</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of anulus fibrosus of mitral orifice (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-47741</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Dorsalis Pedis Artery</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-47740</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of dorsalis pedis artery (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-F6806</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Ductus venosus</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-F680F</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of ductus venosus (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-AB000</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Ear</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-AB001</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Ear structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-AA215</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Entire Cornea</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-AA200</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Corneal structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-1416B</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">External intercostal muscle</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-A0191</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of intracranial vein (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-1553D</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Finger Joint</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-1278B</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Midtarsal bone of foot (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-48470</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Inferior cardiac vein</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-484A4</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of posterior vein of left ventricle (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-A1721</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Inferior Horn of Lateral Ventricle</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-A1720</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of inferior horn of lateral ventricle (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-14183</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Internal intercostal muscle</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-14161</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of external intercostal muscle (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-C4351</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Intra-mammary lymph node</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-C430B</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of intramammary lymph node (body structure)".</emphasis></emphasis></para>
                     <para><emphasis role="bold"><emphasis role="underline">Retired code was used incorrectly and means something else ("Entire internal mammary lymph node (body structure)"). </emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-47651</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">lateral plantar artery</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-47650</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of lateral plantar artery (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-4881F</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Left Main Branch of Portal Vein</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-48814</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of left main branch of portal vein (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-62002</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Liver</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-62000</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Liver structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-47661</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">medial plantar artery</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-47660</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of medial plantar artery (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-1254D</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Metacarpus</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-12540</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Bone structure of metacarpal (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-35313</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Mitral Annulus</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-35110</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of anulus fibrosus of tricuspid orifice (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-51000</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Mouth</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-D0662</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Mouth region structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-D0772</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Myocardial Wall</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-D075D</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Cardiac wall structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-127EC</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Navicular of hindfoot</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-12800</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Bone structure of navicular (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-42231</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Non-coronary Sinus</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-D1400</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Cranial cavity structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-D14AD</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Orbital region</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-D08CA</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of orbital region (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-9200B</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Prostate</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-92000</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Prostatic structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-43203</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Right Coronary Artery</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-43200</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Right coronary artery structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-4882A</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Right Main Branch of Portal Vein</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-48813</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of right main branch of portal vein (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-00009</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Skin</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-01000</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Skin structure (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-11500</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Spine</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-D04FF</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of vertebral column (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-141A5</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Transversus thoracis</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-14163</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of internal intercostal muscle (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-35111</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Tricuspid Annulus</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-42230</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of posterior sinus of Valsalva (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-48817</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Umbilical Vein</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">T-48832</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Replacement code has meaning of "Structure of umbilical portion of portal vein (body structure)".</emphasis></emphasis></para>
                  </td>
               </tr>
            </tbody></table>
    </section>
     
     <section label="L" status="1" xml:id="chapter_L">
        <title>Correspondence of Anatomic Region Codes and Body Part Examined Defined Terms</title>
        <table frame="box" label="L-1" rules="all" xml:id="table_L-1">
           <caption>Corresponding SNOMED Terms for Human Use</caption>
           <thead>
              <tr valign="top">
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_16f26bbc-9190-4ed2-b3a0-147207725c5b">
                       <emphasis role="bold">SNOMED Code Value</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_afc02490-4751-4f51-bf8b-3f09d877f25f">
                       <emphasis role="bold">Code Meaning</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_122bb0a4-46bd-4d89-bd1c-a5a83aefa6f2">
                       <emphasis role="bold">Body Part Examined</emphasis>
                    </para>
                 </th>
              </tr>
           </thead>
           <tbody>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-48440</emphasis>
                          <emphasis role="underline">T-48403</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_3abdaaac-a397-413d-8a53-5bad9e6dbc97">Anterior cardiac vein</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_e7cfb52c-0100-450b-b432-c800c40f515d"/>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-45526</emphasis>
                          <emphasis role="underline">T-45520</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_ffc0b6d4-535c-4673-b337-2beb64e7af48">Circle of Willis</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_44d974ad-bca2-4e3a-8323-b8ebeb3cb866">CIRCLEOFWILLIS</para>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-A0193</emphasis>
                          <emphasis role="underline">T-15516</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_127ef186-7399-49df-8a14-10becc0434c0">Cranial venous system</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_0ac1e424-243e-4e13-a6ab-33db167acb5c"/>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-AB000</emphasis>
                          <emphasis role="underline">T-AB001</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_05bd96d5-ecf4-4577-8a58-abd14bf63e25">Ear</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_37c3a451-6f95-491b-b3fb-46091a60ac90">EAR</para>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-48470</emphasis>
                          <emphasis role="underline">T-484A4</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_d85b228b-5d48-45a9-aeef-e9a98d21fb1e">Inferior cardiac vein</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_86948373-c8ff-4df2-8829-29dedc2a8f91"/>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-51000</emphasis>
                          <emphasis role="underline">T-D0662</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_03a94802-b7d0-48c4-9b76-1b777b548bd1">Mouth</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_83458309-34b7-4938-8778-00b1c157183d">MOUTH</para>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-9200B</emphasis>
                          <emphasis role="underline">T-92000</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_9705793b-6eca-4a40-bbfd-7ddf47f99769">Prostate</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_23b115b2-78d2-4b0f-a067-48eb0e5a0da1">PROSTATE</para>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-48817</emphasis>
                          <emphasis role="underline">T-48832</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_d632f1a8-6114-4d71-a106-b4b238b7a2e3">Umbilical vein</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_a8c17a6f-54b6-4ea6-97bd-4799076ca052"/>
                 </td>
              </tr>
           </tbody>
        </table>
        <table frame="box" label="L-2" rules="all" xml:id="table_L-2">
           <caption>Corresponding SNOMED Terms for Large Animals</caption>
           <thead>
              <tr valign="top">
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_6780b39d-2830-455a-ac41-f80a584c1c8b">
                       <emphasis role="bold">SNOMED Code Value</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_a28351d8-5627-4390-8af8-a061e87d1050">
                       <emphasis role="bold">Code Meaning</emphasis>
                    </para>
                 </th>
                 <th align="center" colspan="1" rowspan="1">
                    <para xml:id="para_9dd486fe-7ff0-4055-a01f-65aabab00df5">
                       <emphasis role="bold">Body Part Examined</emphasis>
                    </para>
                 </th>
              </tr>
           </thead>
           <tbody>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-1531B</emphasis>
                          <emphasis role="underline">T-15317</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_3e7cd4f6-455f-4a37-9f47-01848fbc36f1">Atlantal-axial joint</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_47309ccc-7859-45a5-8101-2a5473c450d6">ATLANTOAXIAL</para>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-11B02</emphasis>
                          <emphasis role="underline">T-11B00</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_96aa3b4e-03b7-47cb-9412-d9acedb654bc">Coccygeal vertrebrae</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_d44f513f-8c2a-422c-b876-14834d157ea5">TAIL</para>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-110A2</emphasis>
                          <emphasis role="underline">T-35310</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_a5203576-cfaf-48c7-a114-1be6a8a872a7">Distal phalanx</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_2f1b49c0-f9c2-4069-8d99-1f50dfa510fb">DISTALPHALANX</para>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-1254D</emphasis>
                          <emphasis role="underline">T-12540</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_8ca587f2-a120-4688-8f58-e11ba7e0a696">Metacarpus</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_1b5fd3a1-aca9-4a3c-b27e-c2a590b17723">METACARPUS</para>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-127EC</emphasis>
                          <emphasis role="underline">T-12800</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_5d1bca8f-bdae-42c7-8a26-3787be70b6f2">Navicular of hindfoot</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_e3c5787e-7e9a-4e66-92a7-4ae15f78c76f">HINDNAVICULAR</para>
                 </td>
              </tr>
              <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                    <para>
                       <emphasis role="bold">
                          <emphasis role="strikethrough">T-D14AD</emphasis>
                          <emphasis role="underline">T-D08CA</emphasis>
                       </emphasis>
                    </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_a726cdd2-29a2-4435-b48d-495c91c6e4fd">Orbital region</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_4d5e7b33-7b52-4dc2-b8d3-869598d26bde"/>
                 </td>
              </tr>
           </tbody>
        </table>
     </section>
  </chapter>
</book>
