<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1673</title>
  <subtitle>Remove Version-specific UIDs from Confidentiality Profile Attributes</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2016/11/24</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>2016/11/21</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1673</para></td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Remove Version-specific UIDs from Confidentiality Profile Attributes</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.15</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                  <para>Creator Version UID and Context Group Extension Creator UID  are not "transient" UIDs that leak identfying information and which need to be removed or remapped, but rather are important for understanding the meaning of the scope that they defines, e.g., private raw data elements in Raw Data IODs.</para>
               </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.15 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="strikethrough">strikethroughd</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
      
      <table frame="box" label="E.1-1" rules="all" xml:id="table_E.1-1">
        <caption>Application Level Confidentiality Profile Attributes</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_c5e6e8ba-34e0-4e31-90b5-bd9ed7086ddd">
                <emphasis role="bold">Attribute Name</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_d02d5580-8438-4a00-8c30-ba93530bcd31">
                <emphasis role="bold">Tag</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_705936dc-2c42-4198-b406-ba0e61b35e99">
                <emphasis role="bold">Retired (from <olink targetdoc="PS3.6" targetptr="PS3.6" xrefstyle="select: labelnumber"/>)</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_a8387cac-386f-4ad9-96b3-b3dcb1b1010c">
                <emphasis role="bold">In Std. Comp. IOD (from <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>)</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_fc0ff9a1-5780-4d06-861a-24ae0ba38b47">
                <emphasis role="bold">Basic Profile</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_19ddb67a-a5d6-474d-a13f-8df27d28b707">
                <emphasis role="bold">Retain Safe Private Option</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_5b335431-5276-4cc0-bddf-93b6d107226e">
                <emphasis role="bold">Retain UIDs Option</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_8317e0cf-0080-48f9-8040-1f49a4478c0f">
                <emphasis role="bold">Retain Device Ident. Option</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_796841da-6b27-4558-99c9-99503edccc6c">
                <emphasis role="bold">Retain Patient Chars. Option</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_edac8181-290b-4f9c-945d-5dfc7b1a43fc">
                <emphasis role="bold">Retain Long. Full Dates Option</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_6305752d-56e7-4f4d-b9d8-e5052fcd6eea">
                <emphasis role="bold">Retain Long. Modif. Dates Option</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_84f3b128-8fe5-45bc-b04e-abc483377b06">
                <emphasis role="bold">Clean Desc. Option</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_0adc5d55-1196-4265-8ee1-b205103c96f1">
                <emphasis role="bold">Clean Struct. Cont. Option</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_5e74e547-b6fd-410e-9c09-b271915c3eeb">
                <emphasis role="bold">Clean Graph. Option</emphasis>
              </para>
            </th>
          </tr>
          
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_6d0023fb-ccd9-4902-8445-ea39595cefee"><emphasis role="bold"><emphasis role="strikethrough">Context Group Extension Creator UID</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1"><emphasis role="bold"><emphasis role="strikethrough">
                <para xml:id="para_a6a8e54d-5f36-40c2-98c6-785ed3aa808b">(0008,010D)</para>
              </emphasis></emphasis></td>
            <td align="center" colspan="1" rowspan="1"><emphasis role="bold"><emphasis role="strikethrough">
                <para xml:id="para_37579bb4-62a9-4820-b887-c6eaa3b8faad">N</para>
              </emphasis></emphasis></td>
            <td align="center" colspan="1" rowspan="1"><emphasis role="bold"><emphasis role="strikethrough">
                <para xml:id="para_a4960b05-c30b-47eb-8396-1e81fcc3e308">Y</para>
              </emphasis></emphasis></td>
            <td align="center" colspan="1" rowspan="1"><emphasis role="bold"><emphasis role="strikethrough">
                <para xml:id="para_0de543d9-da40-434a-97cd-d22efe54b8e4">U</para>
              </emphasis></emphasis></td>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"><emphasis role="bold"><emphasis role="strikethrough">
                <para xml:id="para_4cc24b9d-7c15-492e-ac63-7eb3bf54a352">K</para>
              </emphasis></emphasis></td>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
          </tr>
          
      <tr valign="top">
        <td align="left" colspan="1" rowspan="1">
          <para xml:id="para_d8b951e3-afde-45de-8596-bbdc4f32bde4"><emphasis role="bold"><emphasis role="strikethrough">Creator Version UID</emphasis></emphasis></para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_43922691-c481-434a-93ff-0a07a2ff4804"><emphasis role="bold"><emphasis role="strikethrough">(0008,9123)</emphasis></emphasis></para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_9a3ad9a0-31b4-4057-9dba-20d34c04de2d"><emphasis role="bold"><emphasis role="strikethrough">N</emphasis></emphasis></para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_875a92bc-7447-4c39-8355-93505360d126"><emphasis role="bold"><emphasis role="strikethrough">Y</emphasis></emphasis></para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_515bbcc8-fe89-46e5-905c-cf641f07099c"><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
        </td>
        <td align="center" colspan="1" rowspan="1"/>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_c35cbce9-17a6-4caa-8903-2667b486dfe1"><emphasis role="bold"><emphasis role="strikethrough">K</emphasis></emphasis></para>
        </td>
        <td align="center" colspan="1" rowspan="1"/>
        <td align="center" colspan="1" rowspan="1"/>
        <td align="center" colspan="1" rowspan="1"/>
        <td align="center" colspan="1" rowspan="1"/>
        <td align="center" colspan="1" rowspan="1"/>
        <td align="center" colspan="1" rowspan="1"/>
        <td align="center" colspan="1" rowspan="1"/>
      </tr>
        </tbody>
      </table>
      
    </chapter>