<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1652</title>
    <subtitle>Update DICOM to reflect changes in IHTSDO SNOMED CT-DICOM Subset for JAN 2017 INT Release</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/06/21</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                 xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>2016/08/30</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1652</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Update DICOM to reflect changes in IHTSDO SNOMED CT-DICOM Subset for JAN 2017 INT Release</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Some codes have been retired in the JAN 2017 INT Release of SNOMED CT and it has been agreed to remove them from the IHTSDO SNOMED CT-DICOM Subset and replace them with appropriate alternatives.</para>
                    <para>SCT:28278009 "Micturition (observable entity)" has been inactivated.
                        SNOMED proposed that is possibly equivalent to SCT:364196001 "Micturition feature (observable entity)",
                        but the suggested equivalent term is not a good fit for the only DICOM usage (CID 91),
                        which is to define the functional condition of "during voiding" being present during imaging;
                        we will add our own DCM code for this, since it is so specific
                        (and we already have our own codes for prior to and post voiding, which need also definition improvement).</para>
                    <para>SCT:276556006 "Effect of maternal gestational diabetes on infant (disorder)" has been inactivated. SNOMED proposed that is possibly equivalent to SCT:704144000 "Maternal history of diabetes mellitus (situation)", but the suggested equivalent term is not a good fit for the only DICOM usage (CID 3756), where it is used as "Infant of Gestational Diabetic Mother (IGDM)". There is another SNOMED concept SCT:206499008 "Infant of mother with gestational diabetes (disorder)", which would have been a good fit, but that has been inactivated too (though it maps to the UMLS concept UMLS:C0456029, which has mappings to other schemes). Another current active concept in SNOMED seems to be SCT:18311000119109 "Infant of diabetic mother (finding)" (SRT:F-DD26F, UMLS:C4050349), but that does not incorporate the distinguishing concept of gestational, as opposed to pre-existing, diabetes. Nor does SCT:21584002 "Syndrome of infant of diabetic mother (disorder) (SRT:D8-75100).
                        Since there doesn't seem to be an appropriate SNOMED code, use UMLS:C0456029 " Infant of mother with gestational diabetes").</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="CID 91" status="3" xml:id="sect_CID_91">
            <title>Functional Condition Present During Acquisition</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_aa14973c-86ba-455b-ab76-d656971b1fc1">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_905eccf6-8404-4c27-b8fa-dc680530d2cc">
                            <emphasis role="bold"><emphasis role="strikethrough">20100625</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 91" rules="all" xml:id="table_CID_91">
                <caption>Functional Condition Present During Acquisition</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3cb50199-51c7-4343-a009-670200069d7c">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_947ab8f5-b726-4134-b97a-51f01449550e">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3deae382-768a-4fff-8e4a-1b7b2971c375">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bbc59703-91f3-4c85-af4f-f8f8afddd195">
                                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3c0317dd-d331-4272-a21c-5ddc9598ac07">
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_6daba974-942c-43dc-92a4-f3ee3519dd09">
                                <emphasis role="italic">Include CID 3271<!--<xref linkend="sect_CID_3271" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                                </emphasis>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5239459d-8fa4-4cb9-b66e-d57ad75a90ce"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4ede59b-21b7-4650-95cd-cd6458fb3005"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_540b3da4-bfe0-493c-a17d-c9080383ab7c">SRT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bcf317d6-d763-460c-9b50-643c80c86ab4">
                                <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=43914001" xl:show="new">F-F7100</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e59c2747-371e-4e2f-b4b7-abd21aaae0fa">Phonation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e8b400a2-36e8-4bd8-9966-a2a138cfb60c">
                                <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=43914001" xl:show="new">43914001</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7983f49c-254b-42b5-8909-0fcebfda2106">
                                <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0031577" xl:show="new">C0031577</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd122650-dbe0-4b3e-89fd-230b98edbcd5">SRT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d6ba8192-9a93-4541-928b-59fbb1bd8187">
                                <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=87731000" xl:show="new">F-12300</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5892547b-cb16-448e-ac21-74c1494db6dd">Weight bearing</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e26891bb-885b-43d2-8080-7962766aa6a7">
                                <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=87731000" xl:show="new">87731000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_869d4798-8f46-4290-bdac-2929dba7fe90">
                                <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0231573" xl:show="new">C0231573</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e2889c7-eaf9-4fe9-bc62-9e5786b9f7d8"><emphasis role="bold"><emphasis role="strikethrough">SRT</emphasis><emphasis role="underline">DCM</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d64e197e-b613-4320-85da-c600ae657457">
                                <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=28278009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">F-72230</emphasis></emphasis></link><link linkend="DCM_ddd001" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">ddd001</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0c77aa99-2098-4b6f-9dcc-b9e29b3441c2"><emphasis role="bold"><emphasis role="underline">During v</emphasis><emphasis role="strikethrough">V</emphasis></emphasis>oiding</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93694b07-a9fb-4649-aa12-b1851088adea">
                                <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=28278009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">28278009</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_713956bf-b26c-42fe-bd48-61747ae616c4">
                                <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0042034" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0042034</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8041b6a-5129-4733-b62b-c5e7648625f3">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3ae0eea-a29a-4a44-9f8d-e8fd801eb0dc">
                                <link linkend="DCM_109134" xrefstyle="select: nopage">109134</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4b65f439-cf6c-414e-9ca9-04015665d133">Prior to voiding</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2961c758-0318-4abd-88a8-13bf6f2a7cf5"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8e97e62-e9d2-43df-980d-ba17b5e2d275"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_285ca489-0fa3-4a0d-9540-0d6b6829e159">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1863c35e-d206-46b7-a6f1-99dbe6957fb9">
                                <link linkend="DCM_109135" xrefstyle="select: nopage">109135</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_15ba3705-2811-4814-b8cb-6987a86c1c6c">Post voiding</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1409acbb-6b94-4dbe-86de-38ebcc428330"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9a52189-fe82-4384-9e7e-bf4417eb6f49"/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 3756" status="3" xml:id="sect_CID_3756">
         <title>Cardiac Patient Risk Factors</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_b76aae63-2512-4386-b1c3-cdc3bb94caec">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_26ec701a-c430-44e1-87aa-3c4b1f503bcf">
                      <emphasis role="bold"><emphasis role="strikethrough">20100317</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 3756" rules="all" xml:id="table_CID_3756">
            <caption>Cardiac Patient Risk Factors</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7ecab79d-778b-43be-8493-20960d826191">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cb134565-5a05-44b2-adf8-09e994b184a4">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_18e20030-cacd-41d8-b7a6-762fd43537c8">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e9ff7c0f-d22b-4f63-afd8-8be7c24da151">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f1915562-7fe1-4560-97c5-425b47b2b6ba">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_dc78f1cd-e6f2-4974-8dbb-fecdde413bf0">
                        <emphasis role="bold">NCDR 2.0b Equivalent Code Value</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_83b8495a-38d9-4a4e-a43e-ac7a41def407">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_91cf36f1-4c9b-4b62-820a-e075b5c5cf9f">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=161505003" xl:show="new">G-026D</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d8a9a171-7f2a-48a9-bb72-7c96a916d95a">History of congestive heart failure</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b1320b21-b2d1-4f91-a39c-2e5ef79860f4">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=161505003" xl:show="new">161505003</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e33560c6-8f2a-4d6c-bc76-f55a35c8d3c8">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0455531" xl:show="new">C0455531</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_87a95e19-7067-4013-9d06-f0864b7fbdcc">30</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_524a32b7-ea23-42a8-9d9a-26f13320f32c">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6c0d3456-06b8-4dab-b6c1-8781454bf8fb">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=161445009" xl:show="new">G-023F</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_18a08461-bed2-4a26-b3be-533d78db88b8">History of Diabetes</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ddb811df-93b8-4164-9bab-8878ba2460bf">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=161445009" xl:show="new">161445009</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a327deab-c21e-4812-9f04-02f9db1d79ab">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0455488" xl:show="new">C0455488</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7f1be512-c5b7-4d06-a70a-b3b7121c00f5">31</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8ed6e8f5-48c5-452e-9a35-5828c40f3518">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_08fad696-3468-4b0f-903c-6d9d9a6e1e03">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=414417004" xl:show="new">R-102B6</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_27280e66-ccf4-475c-8aa2-126857118716">History of renal failure</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1d9247e1-675a-4715-8929-349ecd723792">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=414417004" xl:show="new">414417004</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0a1464ad-5169-456e-9de8-561a764c6804">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C1533077" xl:show="new">C1533077</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_44229399-562d-4baa-947c-9435b83b023a">32</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6e94f099-63c7-4ea4-a136-62fd4a930540">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_17f25898-6c15-4071-8797-18c5c34238b9">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=414415007" xl:show="new">R-102B7</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6d26a57f-0453-48ff-9371-b2efc5307da0">History of chronic lung disease</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_da2866ad-c9df-41ae-9ca6-e06763375da6">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=414415007" xl:show="new">414415007</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f1f54d99-025a-4f1b-be2c-f99c3599ea4b">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C1533075" xl:show="new">C1533075</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9581780b-8bf9-4f42-a2fc-e9569d12b0cc">33</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1eff1ba8-7bdc-4a5b-9dcb-6357cdb5d20f">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9308456e-fe21-4a1a-8a53-871ac7ceb319">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=308064009" xl:show="new">G-0102</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_65c4a30a-4f40-421f-9f47-d41ca8bd69c5">History of cerebrovascular disease</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_83679c0c-f491-4e21-8538-9399f8b27a7b">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=308064009" xl:show="new">308064009</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_04a80594-454b-40a3-af17-dc1db765c5fa">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0585890" xl:show="new">C0585890</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_206b4792-2581-4448-94a1-c048b9b2c0ad">34</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_68e6e5e8-65e1-43cf-b58a-968cbd6d68e9">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_320bcdef-a4f7-4fc8-a8e5-35f9fc05e8b7">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=400047006" xl:show="new">D3-8005B</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_71b8e77c-1c5e-4933-b55e-5700c1bc379a">Peripheral vascular disease</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_885bffd6-d856-47b7-a162-50dbc84399ac">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=400047006" xl:show="new">400047006</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d3d83120-619d-4e25-a758-5f0c136636c8">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0085096" xl:show="new">C0085096</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bc3689cb-eb44-41bd-ad8a-98a09b7a25da">35</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c1d0a5c4-b8a8-445b-acd1-b8ac08307efc">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7f0b9975-76e0-4a83-ad16-c469b3dc66e6">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=399211009" xl:show="new">G-03AA</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5c9476b7-169d-49e3-8deb-9e13ca0172e9">History of myocardial infarction</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e5a36f49-a34d-416b-9f27-96cb02d6aad1">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=399211009" xl:show="new">399211009</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0a2c2a0c-ff87-427c-9641-d14e8b78d526">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C1275835" xl:show="new">C1275835</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7bac376b-7a28-47f6-b9f4-116a6d89e9b8">36</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_cd37ed43-cb5e-46be-8d75-eb55af4af29a">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fe00d927-5333-4eab-b310-507fc1acc59c">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=161501007" xl:show="new">G-0269</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e6a4f838-493c-4ac6-b890-2f4041484747">History of Hypertension</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b653ea9a-ca82-4e10-a398-95df8e694e5d">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=161501007" xl:show="new">161501007</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_09b5db21-90da-4232-82e9-8c3c1850bcee">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0455527" xl:show="new">C0455527</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_75549843-039e-48ae-8f9e-550c75312b3a">37</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_44291ca4-79a1-48d1-9dd0-9a0d716c1734">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_15a5dcb6-aec0-41d3-8d91-9fe741659c4c">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=414416008" xl:show="new">R-102B8</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_65f4b4bb-81fa-4fb3-912f-14babfa64794">History of hypercholesterolemia</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f92228d9-6749-402b-bee7-dfe2d1b6adca">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=414416008" xl:show="new">414416008</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3b4c3a5a-c73c-4f1c-adca-5201a5641703">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C1533076" xl:show="new">C1533076</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b4ea02b5-adba-436e-91e2-67645b3eb948">39</para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_002e1e47-b0c5-4378-8183-b67f3959e04d">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_02914d67-7e6b-45cc-a3c2-2e5269ca96e2">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=44808001" xl:show="new">D3-30000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_970ebb7b-ffd4-4248-8273-834b82df7c1c">Arrhythmia</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1df741fd-41c6-4018-8ac5-e5acebe42a3a">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=44808001" xl:show="new">44808001</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_02839752-b87f-458b-b8af-7f4c2f65021a">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0264886" xl:show="new">C0264886</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_496c458b-0008-4c26-87b8-39932ab111c4"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1f2389ee-8bb6-4716-af05-f50986e412ba">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b007d1d8-dcab-4080-8d0d-b335648f51f5">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=165816005" xl:show="new">F-0331B</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_5674f701-989f-4f31-90cf-4eac21831b71">HIV Positive</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bcd81bb7-8189-49f4-9ac6-434efeb6ca27">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=165816005" xl:show="new">165816005</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6ddcea86-a82b-432c-830e-9ae5b096307b">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0019699" xl:show="new">C0019699</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_741c47a1-73ce-4206-9b52-29558a65ebf5"/>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_85f09a72-add9-47ae-9526-a93d9e003538"><emphasis role="bold"><emphasis role="strikethrough">SRT</emphasis><emphasis role="underline">UMLS</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9e028334-08a2-4748-9895-790002d3b9fe">
                         <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=276556006" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">D8-60001</emphasis></emphasis></link><link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0456029" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0456029</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_2a947ae4-aabc-4fa1-9e02-5a03d7eaf1b1">Infant of <emphasis role="bold"><emphasis role="strikethrough">Gestational Diabetic M</emphasis><emphasis role="underline">m</emphasis></emphasis>other <emphasis role="bold"><emphasis role="strikethrough">(IGDM)</emphasis><emphasis role="underline">with gestational diabetes</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_43b7d7fb-9e85-452c-aef1-e9dcb76e518d">
                         <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=276556006" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">276556006</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_28a8764b-59e0-4c6a-a9df-ebbc4b967fc3">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0456029" xl:show="new">C0456029</link>
                     </para>
                  </td>
                   <td align="center" colspan="1" rowspan="1">
                       <para/>
                   </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_60514546-c373-40e1-a6aa-9bc12f5f833f">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f4900a8a-0676-4844-b854-083240f6fdf2">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=444161008" xl:show="new">G-0586</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_d22bf0d2-fa52-459c-abfe-d04216fbe7d3">Insulin dependent mother (IDM)</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a914b6b9-d4db-4ea2-945b-b65e36b0645d">
                        <link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=444161008" xl:show="new">444161008</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9eb87a1c-3552-48b6-8073-2b64231a5d10">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C2732238" xl:show="new">C2732238</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ab75a6fa-e394-4bfd-b130-a798d297db5e"/>
                  </td>
               </tr>
            </tbody>
         </table>
         <note/>
      </section>
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            <para xml:id="para_89a5e18f-1781-4007-be8c-654d60de917b">DICOM Code Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</para>
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">
                                <emphasis role="bold">Definition</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">
                                <emphasis role="bold">Notes</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
        
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_109134">109134</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_ffc5cf08-bb3b-4c74-aa90-5e79cb45e29e">Prior to voiding</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_6497fbe4-4877-4a0a-9b74-cc07fd667ce4">Prior to voiding<emphasis role="bold"><emphasis role="underline"> urine from the bladder</emphasis></emphasis>.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_76d01380-2f6e-4f80-88d0-99e8fdf7e78a"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_109135">109135</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_211c99da-0929-4b75-8bf2-1785e9cdcac5">Post voiding</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_693ac0ca-31a8-4db0-b46a-760f18f9fe9d">Post voiding<emphasis role="bold"><emphasis role="underline"> urine from the bladder</emphasis></emphasis>.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_ec685dd0-0657-472a-9303-c93ad989e4e2"/>
            </td>
        </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd001"><emphasis role="bold"><emphasis role="underline">ddd001</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">During voiding</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">During voiding urine from the bladder</emphasis></emphasis>.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
                
        
        
        <section label="J" status="1" xml:id="chapter_J">
            <title>SNOMED Retired Codes</title>
            <table frame="box" label="J-1" rules="all" xml:id="table_J-1">
                <caption>SNOMED Codes Retired from DICOM Use</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba15f948-561c-4cf6-a7c8-451b15b4d601">
                                <emphasis role="bold">Retired Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64a0b043-59fc-410d-a39e-81671a662f04">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a1e2c06a-1e64-4fd5-9ffb-0da12a76aeb2">
                                <emphasis role="bold">Replacement Code</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_246a7171-2a92-45ac-80b1-7ed33ffc877b">
                                <emphasis role="bold">Notes</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"><link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=28278009" xl:show="new">F-72230</link></emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Voiding</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">No SNOMED replacement. Replaced by </emphasis></emphasis><link linkend="DCM_ddd001" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">(ddd001, DCM, "During voiding")</emphasis></emphasis></link></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><link xl:href="http://browser.ihtsdotools.org/?perspective=full&amp;conceptId1=276556006" xl:show="new"><emphasis role="bold"><emphasis role="underline">D8-60001</emphasis></emphasis></link></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Infant of Gestational Diabetic Mother (IGDM)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">No SNOMED replacement. Replaced by </emphasis></emphasis><link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C0456029" xl:show="new"><emphasis role="bold"><emphasis role="underline">(C0456029, UMLS, "Infant of mother with gestational diabetes")</emphasis></emphasis></link></para>
                            <para><emphasis role="bold"><emphasis role="underline">Retired code is inactive in SNOMED CT.</emphasis></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
    </chapter>
</book>