<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1620</title>
  <subtitle>Clarify that conformance reference requirements do not serve in lieu of a form conformance statement</subtitle>
    <chapter>
      <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2016/11/09</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>2016/03/26</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1620</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Clarify that conformance reference requirements do not serve in lieu of a form conformance statement</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.1, PS3.2</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The requirements with respect to referencing the standard do not eliminate the need to provide a conformance statement, but might be confused in that regard.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td><para><emphasis role="italic">Amend DICOM PS 3.1:</emphasis></para></td>
        </tr>
      </informaltable>
    </section>
        
        <section label="1.4.4" status="3" xml:id="sect_1.4.4">
            <title>Conformance</title>
            <para>Conformance to the DICOM Standard is stated in terms of Service-Object Pair (SOP) Classes, which represent Services
                (such as Storage using network, media, or web) operating on types of Information Objects  (such as CT or MR images).</para>
            <para>SOP Class specifications in the DICOM Standard are only changed in a manner that is intended to be forward and backward
                compatible for all editions of the Standard. Conformance requirements and conformance claims are therefore referenced to the
                identifier of the SOP Class, and never referenced to an edition of the Standard.</para>
            <para>Each implementation is required to provide a Conformance Statement, in accordance with a consistent <foreignphrase xml:lang="la">pro forma</foreignphrase> structure,
                facilitating comparison of products for interoperability.</para>
        </section>
        
        <para>...</para>
        
        <section label="7" status="1" xml:id="chapter_7">
            <title>Referencing The DICOM Standard</title>
            <para xml:id="para_0a7c601c-1749-44bd-b8e5-516a60750a02">Under the procedures of the DICOM Standards Committee, the Standard is in constant revision. Supplements and corrections to the Standard are balloted and approved several times a year. Each change when approved as Final Text immediately goes into effect. At intervals, all of the approved Final Text changes are consolidated into a published edition of the Standard, identified by year of publication, but such publication is only a convenience to the user; the Standard is officially changed when each change is approved.</para>
            <para xml:id="para_dfc3171c-6c12-4b9f-afdd-cb3ec45e94d1">Conformance to the DICOM Standard is through specified SOP Classes using DIMSE messages (see PS3.4<!--<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>-->), Web Services (see PS3.18<!--<olink targetdoc="PS3.18" targetptr="PS3.18" xrefstyle="select: labelnumber"/>-->), media interchange (see Annex I in PS3.4<!--<olink targetdoc="PS3.4" targetptr="chapter_I" xrefstyle="template:Annex %n “%t” in PS3.4"/>--> and PS3.10<!--<olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/>-->), or the hosted application API (see PS3.19<!--<olink targetdoc="PS3.19" targetptr="PS3.19" xrefstyle="select: labelnumber"/>-->). Additional conformance claims may be made to Profiles (see PS3.11<!--<olink targetdoc="PS3.11" targetptr="PS3.11" xrefstyle="select: labelnumber"/>--> and PS3.15<!--<olink targetdoc="PS3.15" targetptr="PS3.15" xrefstyle="select: labelnumber"/>-->). Once such a unit of conformance is specified in the Standard, all changes thereto are forward and backward compatible
                (except in rare cases where the original specification was non-interoperable, or conflicted with another standard). Conformance requirements and conformance claims are therefore referenced to the name and/or identifier of the feature, and never referenced to an edition of the Standard. Generally, the only appropriate reference to a particular edition of the Standard is to identify a retired feature (see Section 1.4.2<!--<xref linkend="sect_1.4.2" xrefstyle="select: label title"/>-->).</para>
            <para xml:id="para_9b0cee4f-2d62-41a2-9cb1-f6f7fe9a40cd">The following citation form is preferred for general references to the Standard, without specification of date of edition, when specific conformance requirements are not invoked:</para>
            <para xml:id="para_803149b0-2dba-41e7-a472-4a25b1c89d71">NEMA PS3 / ISO 12052, Digital Imaging and Communications in Medicine (DICOM) Standard, National Electrical Manufacturers Association, Rosslyn, VA, USA (available free at <link xl:href="http://medical.nema.org/"/>)</para>
            <para><emphasis role="bold"><emphasis role="underline">The requirements of this section do not override the requirement to provide a DICOM Conformance Statement as described in PS3.2<!--<olink targetdoc="PS3.2" targetptr="PS3.2" xrefstyle="select: labelnumber"/>-->.</emphasis></emphasis></para>
            <para xml:id="para_ac213f23-6621-4a16-b519-c5846ef26809">The following forms are preferred for references to units of conformance to the Standard<emphasis role="bold"><emphasis role="underline"> when they are made outside the context of a DICOM Conformance Statement (e.g., in customer requirements):</emphasis></emphasis>:</para>
            <para xml:id="para_75989daf-c499-4f83-bf67-5ef4e16f85ed">
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_523cf9cf-8e9f-4abb-a2e1-8eccb00854cc">
                            <quote>… conformant to the DICOM &lt;name&gt; SOP Class for network exchange [as a Service Class &lt;User | Provider&gt;], as specified in DICOM PS3.4<!--<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>-->: Service Class Specifications.</quote>
                        </para>
                    </listitem>
                    <listitem>
                        <para>
                            <quote>… conformant to the DICOM &lt;name&gt; SOP Class for media exchange [as a File Set &lt;Creator | Updater | Reader&gt;], as specified in DICOM PS3.4<!--<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>-->: Service Class Specifications.</quote>
                        </para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_0da85449-f995-46bf-8f21-05e694a2fce2">
                            <quote>… conformant to the DICOM &lt;name&gt; Web Service [as &lt;an Origin-server | a User-agent&gt;], as specified in DICOM PS3.18<!--<olink targetdoc="PS3.18" targetptr="PS3.18" xrefstyle="select: labelnumber"/>-->: Web Services.</quote>
                        </para>
                    </listitem>
                    <listitem>
                        <para>
                            <quote>… conformant to DICOM Application Hosting [as a &lt;Hosting System | Hosted Application&gt;], as specified in DICOM PS3.19<!--<olink targetdoc="PS3.19" targetptr="PS3.19" xrefstyle="select: labelnumber"/>-->: Application Hosting.</quote>
                        </para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_5ed5702a-47bb-4ed7-a952-85d0a757bef1">
                            <quote>… conformant to the DICOM &lt;identifier&gt; Application Profile [as a File Set &lt;Creator | Updater | Reader&gt;] [&lt;name&gt; SOP Class], as specified in DICOM PS3.11<!--<olink targetdoc="PS3.11" targetptr="PS3.11" xrefstyle="select: labelnumber"/>-->: Media Storage Application Profiles.</quote>
                        </para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_f6633f45-7c5f-4ee0-974a-17ef5d94ace8">
                            <quote>… conformant to the DICOM &lt;name&gt; Profile, as specified in DICOM PS3.15<!--<olink targetdoc="PS3.15" targetptr="PS3.15" xrefstyle="select: labelnumber"/>-->: Security and System Management Profiles.</quote>
                        </para>
                    </listitem>
                </itemizedlist>
            </para>
            <note>
                <orderedlist>
                    <listitem>
                        <para>Some Application Profiles and Web Services may fully specify the information objects exchanged, while others may require explicit specification of SOP Classes in the references.</para>
                    </listitem>
                    <listitem>
                        <itemizedlist>
                            <listitem>
                                <para>
                                    <quote>The modality shall be conformant to the DICOM CT Image Storage and MR Image Storage SOP Classes for network exchange as a Service Class User, as specified in DICOM PS3.4<!--<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>-->: Service Class Specifications.</quote>
                                </para>
                            </listitem>
                            <listitem>
                                <para>
                                    <quote>The workstation shall be conformant to the DICOM STD-XA1K-DVD Application Profile as a File Set Reader, as specified in DICOM PS3.11<!--<olink targetdoc="PS3.11" targetptr="PS3.11" xrefstyle="select: labelnumber"/>-->: Media Storage Application Profiles.</quote>
                                </para>
                            </listitem>
                            <listitem>
                                <para>
                                    <quote>The PACS shall be conformant to the DICOM WADO-RS and STOW-RS Web Services as an Origin-server for the SOP Classes listed in Table X, as specified in DICOM PS3.18<!--<olink targetdoc="PS3.18" targetptr="PS3.18" xrefstyle="select: labelnumber"/>-->: Web Services.</quote>
                                </para>
                            </listitem>
                        </itemizedlist>
                    </listitem>
                    <listitem>
                        <para><emphasis role="bold"><emphasis role="underline">Such references are not permitted in lieu of a Conformance Statement for a product. For example, a product that reads or creates DICOM interchange media is required to have a Conformance Statement (as described in PS3.2<!--<olink targetdoc="PS3.2" targetptr="PS3.2" xrefstyle="select: labelnumber"/>-->) that enumerates the Media Application Profiles it implements. A statement in some other format, or a document that describes that a product supports recording of files of a particular SOP Class defined in PS3.4<!--<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>-->, is not sufficient as an alternative to a Conformance Statement. </emphasis></emphasis></para>
                    </listitem>
                </orderedlist>
            </note>
            <para xml:id="para_c9e802a6-27c9-4dea-9de0-1bcdda57a7ef">Reference may be made to other features of the Standard, but these shall not be construed as DICOM conformance requirements (although they may be conformance requirements for non-DICOM implementation guides or regulations). Following are some examples:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_48fabc2e-e5c0-4777-9155-27f1b401f294">
                        <quote>… SOP Instances in accordance with the &lt;name&gt; Information Object Definition, as specified in DICOM PS3.3<!--<olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>-->: Information Object Definitions.</quote>
                    </para>
                </listitem>
                <listitem>
                    <para xml:id="para_d76ee814-eae9-4cba-90d0-27ee15dfd64a">
                        <quote>… Structured Reporting SOP Instances using DICOM Template ID &lt;number and name&gt;, as specified in DICOM PS3.16<!--<olink targetdoc="PS3.16" targetptr="PS3.16" xrefstyle="select: labelnumber"/>-->: Content Mapping Resource.</quote>
                    </para>
                </listitem>
                <listitem>
                    <para>
                        <quote>… HL7 CDA instances using Template ID &lt;identifier and name&gt;, as specified in DICOM PS3.20<!--<olink targetdoc="PS3.20" targetptr="PS3.20" xrefstyle="select: labelnumber"/>-->: Imaging Reports using HL7 Clinical Document Architecture.</quote>
                    </para>
                </listitem>
                <listitem>
                    <para xml:id="para_69afa62e-a8cc-433f-a899-16e9fcf16d7b">
                        <quote>… using the &lt;name&gt; Transfer Syntax, as specified in DICOM PS3.5<!--<olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>-->: Data Structure and Semantics.</quote>
                    </para>
                </listitem>
            </itemizedlist>
            <note>
                <para>For example, products producing or receiving SR documents must conform to a SOP Class, such as Enhanced SR; such products may also cite use of Template ID 5200 Echocardiography Procedure Report, but that is not a formal DICOM Conformance assertion. However, a non-DICOM implementation guide, such as the IHE Echocardiography Workflow Profile, may require use of that Template, and an implementation may describe its use of specific Templates in its Conformance Statement.</para>
            </note>
            <para xml:id="para_c8fca69e-e2f5-4ebe-8acb-3eb5d88ac3cd">Since changes to the Standard shall not be cited prior to adoption as Final Text, and since after adoption they are formally part of the Standard, there should be no citations to supplements or correction items for the purpose of describing conformance. Reference to such change documents may be made for describing the historical development of the DICOM Standard.</para>
        </section>
       
    </chapter>
</book>