<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
   <title>CP-1603</title>
  <subtitle>Enhance Coding Schemes Table</subtitle>
    <chapter>
      <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/01/21</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>Jörg Riesmeier</para><para><link xl:href="mailto:dicom@jriesmeier.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>2016/02/23</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1603</para></td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Enhance Coding Schemes Table</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3, PS3.6, PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                   <para>Table 8-1 (Coding Schemes) in PS3.16 (Content Mapping Resource) lists the coding schemes defined for use in DICOM.
                      However, it does not always contain sufficient or easy to find information for filling some optional attributes of
                      the Coding Scheme Identification Sequence (0008,0110) in the SOP Common Module,
                      e.g. the Coding Scheme Name (0008,0115) or the Coding Scheme Responsible Organization (0008,0116).</para>
                   <para>It is proposed to introduce additional columns to Table 8-1 that contain such information explicitly (if available).
                      Having separate columns for this purpose makes it easier to extract this information automatically from the
                      machine-readable DocBook/XML version of the DICOM standard text.
                      In order to avoid redundancy, the text in the "Description" column should also be revised.</para>
               <para>Also, link to the Normative Reference section entries where appropriate. </para>
                   <para>In addition, it is useful to provide URLs that link to documentation, representations or services related to the coding scheme,
                   and it should be possible to encode these in the IOD.</para>
                   <para><emphasis role="italic">[Open issue: Should more information be given on each coding scheme (e.g. at least a URL if available) ? Currently, the amount of information in the "Description" column is quite different.]</emphasis></para>
                   <para><emphasis role="italic">[Open issue: Not sure whether Table 8-2. "HL7v3 Coding Schemes" should also be enhanced in this respect. Would it be reasonable to add more text to the "Description" column?]</emphasis></para>
                   <para><emphasis role="italic">[Open issue: The spelling of the term "Coding Scheme" is not consistent throughout PS3.16. This even applies to the below cited Section 8.Furthermore, in Section 3.1 "Codes and Controlled Terminology Definitions", the spelling "Coding schemes" is used. Wouldn't "Coding Scheme" (upper case "S" and singular) make more sense?]</emphasis></para>
               <para><emphasis role="italic">[Open issue: Currently only documents, CSV and OWL file URL types are defined; are there standard "terminology service APIs that should be added, e.g., UMLS SOAP or REST API, or does that require extensive research/testing/justification?]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
       
       <section>
          <title/>
          <informaltable rules="all" frame="box">
             <tr>
                <td><para><emphasis role="italic">Amend DICOM PS 3.3:</emphasis></para></td>
             </tr>
          </informaltable>
       </section>
       
       <section label="8" status="1" xml:id="chapter_8">
    <title>Encoding of Coded Entry Data</title>
    <section label="8.2" status="2" xml:id="sect_8.2">
      <title>Coding Scheme Designator and Coding Scheme Version</title>
      <para xml:id="para_f787c3d3-3457-48e3-9331-b5dbaa55a10b">The attribute Coding Scheme Designator (0008,0102) identifies the coding scheme in which the code for a term is defined. Standard coding scheme designators used in DICOM information interchange are listed in <olink targetdoc="PS3.16" targetptr="PS3.16" xrefstyle="select: labelnumber"/>. Other coding scheme designators, for both private and public coding schemes, may be used, in accordance with <olink targetdoc="PS3.16" targetptr="PS3.16" xrefstyle="select: labelnumber"/>. Further identification of the coding scheme designators used in a SOP Instance may be provided in the Coding Scheme Identification Sequence (0008,0110) (see <xref linkend="sect_C.12.1" xrefstyle="select: label"/>).</para>
      <note>
        <orderedlist numeration="arabic">
          <listitem>
            <para xml:id="para_de1cec76-697d-4fde-9d2f-ac98469e64ef">Typical coding schemes used in DICOM include "DCM" for DICOM defined codes, "SRT" for SNOMED, and "LN" for LOINC. See <olink targetdoc="PS3.16" targetptr="chapter_8" xrefstyle="template:Annex %n “%t” in PS3.16"/>.</para>
          </listitem>
          <listitem>
            <para xml:id="para_69b55b63-f447-4c72-a4ba-4e4a6abff652">Coding scheme designators beginning with "99" and the coding scheme designator "L" are defined in HL7 V2 to be private or local coding schemes.</para>
          </listitem>
          <listitem>
            <para xml:id="para_37b217cf-ced6-406a-bba8-78f7ab1d5e16">Most IODs that define the use of coded terms provide for the use of private codes and coding schemes through replacement of Baseline Context Groups or extension of Defined Context Groups. Systems supporting such private code use must provide a mechanism for the configuration of sets of Coding Scheme Designator (0008,0102), Code Value (0008,0100) (or Long Code Value (0008,0119) or URN Code Value (0008,0120)), and Code Meaning (0008,0104) to support interoperation of the private codes with other systems.</para>
          </listitem>
          <listitem>
            <para xml:id="para_f424a3a8-bb11-4f57-a145-a84a51db987c">It is highly recommended that local or non-standard coding schemes be identified in the Coding Scheme Identification Sequence <emphasis role="bold"><emphasis role="underline">(0008,0110)</emphasis></emphasis>. <emphasis role="bold"><emphasis role="underline">Documents or machine readable representations of the coding scheme (e.g., CSV or OWL files) can be linked to via a Coding Scheme URL (0008,eee2).</emphasis></emphasis></para>
          </listitem>
          <listitem>
            <para xml:id="para_03d7f904-f5c0-4892-90e1-59e40e8fc26b">URN and URL codes usually lack a Coding Scheme Designator (0008,0102).</para>
          </listitem>
        </orderedlist>
      </note>
      <para xml:id="para_fefa94dd-fd94-4adf-84b9-dd4479d296be">The attribute Coding Scheme Version (0008,0103) may be used to identify the version of a coding scheme if necessary to resolve ambiguity in Code Value (0008,0100), Long Code Value (0008,0119) or URN Code Value (0008,0120). Coding Scheme Version (0008,0103) is not required for backward-compatible revisions of a coding scheme, as the Coding Scheme Designator (0008,0102) identifies the coding scheme as a whole as currently published by the responsible organization.</para>
      <note>
        <orderedlist numeration="arabic">
          <listitem>
            <para xml:id="para_028ec625-30b4-4e41-b8e7-39715a78cdab">See <olink targetdoc="PS3.16" targetptr="PS3.16" xrefstyle="select: labelnumber"/> for a discussion of SNOMED Coding Scheme Designators 99SDM, SNM3, and SRT.</para>
          </listitem>
          <listitem>
            <para xml:id="para_667d4ef0-5887-4fba-84ed-0563683e7ee1">ICD-10, for example, is not a backward-compatible revision of ICD-9, and hence it has a different Coding Scheme Designator, not simply a different Coding Scheme Version.</para>
          </listitem>
        </orderedlist>
      </note>
    </section>
  </section>
       
       <section label="C.12.1" status="3" xml:id="sect_C.12.1">
        <title>SOP Common Module</title>
        <table frame="box" label="C.12-1" rules="all" xml:id="table_C.12-1">
          <caption>SOP Common Module Attributes</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_86caed0d-a734-44a9-b3fa-f2224d719bcc">Attribute Name</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_ec64be98-77ae-4fa5-9bac-b84253ffbf75">Tag</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_9165c006-7f35-4ef0-864c-d2c66ab6cfb6">Type</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_02261e99-408e-4d8c-86fa-91d6a19a4b74">Attribute Description</para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_3300a8cf-f830-434a-b490-eab75bfa2b81">...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_8ac8b861-ca19-4829-b22c-e890071795b1">...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_747ef5e5-bd40-4077-ad64-84be6f98fb78">...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_4f25a9e9-3b95-4478-9e12-7851485cb02d">...</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_9e41f274-88af-4bfd-9b1c-8b4e2d7545f7">Coding Scheme Identification Sequence</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_89043032-5616-4e0c-8758-c4669842881f">(0008,0110)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_511595ad-49ed-4e94-b00b-976d3c75014e">3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_e4f3c717-aaf9-4a15-8399-c4b082addedb">Sequence of items that map values of Coding Scheme Designator (0008,0102) to an external coding system registration, or to a private or local coding scheme.</para>
                <para xml:id="para_15cbbdd6-fab7-40f4-9748-dab329567337">One or more Items are permitted in this Sequence.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_e93a9fd8-9dd5-407c-afa5-83dc13e254fa">&gt;Coding Scheme Designator</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_365aa64c-78bc-4a44-9e1d-a3f76e4ee360">(0008,0102)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_64784781-0ee3-4307-b400-7d80146a2ad7">1</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_6873aa6c-671d-45aa-b0dc-b6737101e1b4">The value of a Coding Scheme Designator, used in this SOP Instance, which is being mapped.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_57983e33-b3df-4439-8ed9-e3a0919fe42f">&gt;Coding Scheme Registry</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_f9e12526-82c3-4c41-8567-808f796309cb">(0008,0112)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_003a4cef-7d68-42d5-9179-ee9211242c4b">1C</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_b553072e-29b9-43dc-ae7b-b82133cf0451">The name of the external registry where further definition of the identified coding scheme may be obtained. Required if coding scheme is registered.</para>
                <variablelist spacing="compact">
                  <title>Defined Terms:</title>
                  <varlistentry>
                    <term>HL7</term>
                    <listitem>
                      <para xml:id="para_81343ddc-ea06-409d-8740-b2bef569c29c"/>
                    </listitem>
                  </varlistentry>
                </variablelist>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_bfee49eb-b8f5-4c2a-8a15-8dc07a940ed4">&gt;Coding Scheme UID</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_142e279a-cc3a-433a-b247-a7636f9d0ca0">(0008,010C)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_02dde1cd-79a2-402e-a9a4-b0c837bc6b8a">1C</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_836a8a34-802c-4fc3-ae18-861342a3b2df">The coding scheme UID identifier. Required if coding scheme is identified by an ISO 8824 object identifier compatible with the UI VR.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_fed182d1-f67c-41f8-a58d-3164230af8f3">&gt;Coding Scheme External ID</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_85a49e78-bbbb-483d-b1ed-f4769a1c7adf">(0008,0114)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_96c23b45-c7a5-467b-bc3f-a558f0b750a4">2C</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_238e873f-ebd6-4f49-8256-186228c0b844">The coding scheme identifier as defined in an external registry. Required if coding scheme is registered and Coding Scheme UID (0008,010C) is not present.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_45e62f33-688c-4d85-9bad-369492b7905c">&gt;Coding Scheme Name</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_b621c640-1180-441f-bb9d-7e6346681150">(0008,0115)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_8e81523d-fa36-47cb-9627-7a05fd5af35b">3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_cb7428a8-6639-4baa-9f5d-264f4f07cdfc">The coding scheme full common name</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_ca7a1cd6-b157-4802-bbb3-a9d6fbf8cb93">&gt;Coding Scheme Version</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_4128f3c0-aa1a-4dbc-8297-049d2b4cc7cc">(0008,0103)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_161c7eba-1f91-4458-9407-980a9ea4ef09">3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_2f15e6a0-5c2b-42e9-9a05-efe35b6d2147">The coding scheme version associated with the Coding Scheme Designator (0008,0102).</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_9e792ad9-0e51-4e9c-be0d-5084c536e87e">&gt;Coding Scheme Responsible Organization</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_2af8398c-50eb-45f0-9bd8-3a49519f6f99">(0008,0116)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_bd779c1e-f390-4f2c-b707-d38a8d41c4a9">3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_1ad50513-7495-4013-abb6-640eb7d139cd">Name of the organization responsible for the Coding Scheme. May include organizational contact information.</para>
              </td>
            </tr>
             <tr>
                <td align="left" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">&gt;Coding Scheme Resources Sequence</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">(0008,eee0)</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">Resources related to the coding scheme.</emphasis></emphasis></para>
                   <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this Sequence.</emphasis></emphasis></para>
                </td>
             </tr>
             <tr>
                <td align="left" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;Coding Scheme URL Type</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">(0008,eee1)</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">The type of the resource related to the coding scheme at the Coding Scheme URL (0008,eee2).</emphasis></emphasis></para>
                   <variablelist spacing="compact">
                   <title><emphasis role="bold"><emphasis role="underline">Defined Terms:</emphasis></emphasis></title>
                      <varlistentry>
                         <term><emphasis role="bold"><emphasis role="underline">DOC</emphasis></emphasis></term>
                         <listitem>
                            <para><emphasis role="bold"><emphasis role="underline">Documents or pages describing the coding scheme.</emphasis></emphasis></para>
                         </listitem>
                      </varlistentry>
                      <varlistentry>
                         <term><emphasis role="bold"><emphasis role="underline">OWL</emphasis></emphasis></term>
                         <listitem>
                            <para><emphasis role="bold"><emphasis role="underline">An OWL file that defines the coding scheme.</emphasis></emphasis></para>
                         </listitem>
                      </varlistentry>
                      <varlistentry>
                         <term><emphasis role="bold"><emphasis role="underline">CSV</emphasis></emphasis></term>
                         <listitem>
                            <para><emphasis role="bold"><emphasis role="underline">A comma separated value text file that defines the coding scheme.</emphasis></emphasis></para>
                         </listitem>
                      </varlistentry>
                   </variablelist>
                </td>
             </tr>
             <tr>
                <td align="left" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;Coding Scheme URL</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">(0008,eee2)</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                   <para><emphasis role="bold"><emphasis role="underline">A resource related to the coding scheme.</emphasis></emphasis></para>
                </td>
             </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_644bd76f-4cf1-4f05-ab11-7306f85b2d86">...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_aa9875d5-d4fd-4b0e-909a-8308bd6c354c">...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_a5da5ac1-2994-4e05-97de-59a3904b1de0">...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_1a071ea9-565f-495e-b6ef-a3134c90ebea">...</para>
              </td>
            </tr>            
          </tbody>
        </table>
      </section>
       
       <section>
          <title/>
          <informaltable rules="all" frame="box">
             <tr>
                <td><para><emphasis role="italic">Amend DICOM PS 3.6:</emphasis></para></td>
             </tr>
          </informaltable>
       </section>
       
       <section label="6" status="1" xml:id="chapter_6">
          <title>Registry of DICOM Data Elements</title>
          
          <table frame="box" label="6-1" rules="all" xml:id="table_6-1">
             <caption>Registry of DICOM Data Elements</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_3e8c52d5-3582-4ec4-a7e6-acd7604caf32">
                         <emphasis role="bold">Tag</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_ac298c3b-bcdd-462b-9240-c38e738bfb7c">
                         <emphasis role="bold">Name</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_99f6b0ff-e1b0-484e-83b5-c3003d61704c">
                         <emphasis role="bold">Keyword</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_42b3621d-8b30-46eb-8992-10bb21310ac7">
                         <emphasis role="bold">VR</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_551ea829-a949-4bfd-a201-bb102024e64c">
                         <emphasis role="bold">VM</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_3a18713f-2e81-4664-b9a1-e4e3d41957ab"/>
                   </th>
                </tr>
             </thead>
             <tbody>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">(0008,eee0)</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Coding Scheme Resources Sequence</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Coding​Scheme​Resources​Sequence</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">SQ</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para/>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">(0008,eee1)</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Coding Scheme URL Type</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Coding​Scheme​URL​Type</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">CS</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para/>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">(0008,eee2)</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Coding Scheme URL</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Coding​Scheme​URL</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">UR</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para/>
                   </td>
                </tr>
             </tbody>
          </table>
       </section>
       
       <section>
          <title/>
          <informaltable rules="all" frame="box">
             <tr>
                <td><para><emphasis role="italic">Amend DICOM PS 3.16:</emphasis></para></td>
             </tr>
          </informaltable>
       </section>
       
       <section label="2" status="1" xml:id="chapter_2">
      <title>Normative References</title>
      <bibliography>
         <title/>
         <bibliodiv label="2.1" status="2" xml:id="sect_2.1">
            <title>General</title>
            <biblioentry xml:id="biblio_ASTM_E2084_00">
               <abbrev>ASTM E 2084-00</abbrev>
               <author>
                  <orgname>ASTM</orgname>
               </author>
               <date/>
               <title>Standard Specification for Authentication of Healthcare Information Using Digital Signatures, ASTM International</title>
            </biblioentry>
            <biblioentry xml:id="biblio_ISO_639">
               <abbrev>ISO 639</abbrev>
               <author>
                  <orgname>ISO</orgname>
               </author>
               <date/>
               <title>Codes for the representation of names of languages</title>
            </biblioentry>
            <biblioentry xml:id="biblio_ISO_639-1">
               <abbrev>ISO 639-1</abbrev>
               <author>
                  <orgname>ISO</orgname>
               </author>
               <date>2002</date>
               <title>Codes for the representation of names of languages — Part 1: Alpha-2 code</title>
            </biblioentry>
            <biblioentry xml:id="biblio_ISO_639-2">
               <abbrev>ISO 639-2</abbrev>
               <author>
                  <orgname>ISO</orgname>
               </author>
               <date>1998</date>
               <title>Codes for the representation of names of languages — Part 2: Alpha-3 code</title>
            </biblioentry>
            <biblioentry xml:id="biblio_ISO_639-3">
               <abbrev>ISO 639-3</abbrev>
               <author>
                  <orgname>ISO</orgname>
               </author>
               <date>2007</date>
               <title>Codes for the representation of names of languages — Part 3: Alpha-3 code for comprehensive coverage of languages</title>
            </biblioentry>
            <biblioentry xml:id="biblio_ISO_3166">
               <abbrev>ISO 3166</abbrev>
               <author>
                  <orgname>ISO</orgname>
               </author>
               <date/>
               <title>Codes for the representation of names of countries</title>
            </biblioentry>
            <biblioentry xml:id="biblio_ISO_3166-1">
               <abbrev>ISO 3166-1</abbrev>
               <author>
                  <orgname>ISO</orgname>
               </author>
               <date/>
               <title>Codes for the representation of names of countries — Part 1: Country codes</title>
            </biblioentry>
            <biblioentry xml:id="biblio_ISO_8824-1">
                  <abbrev><emphasis role="bold"><emphasis role="underline">ISO 8824-1</emphasis></emphasis></abbrev>
                  <author>
                     <orgname><emphasis role="bold"><emphasis role="underline">ISO</emphasis></emphasis></orgname>
                  </author>
                  <date><emphasis role="bold"><emphasis role="underline">2015</emphasis></emphasis></date>
                  <title><emphasis role="bold"><emphasis role="underline">Information Technology - Abstract Syntax 1 (ASN.1): Specification of Basic Notation</emphasis></emphasis></title>
               </biblioentry>
            <biblioentry xml:id="biblio_ISO_9834-1">
                  <abbrev><emphasis role="bold"><emphasis role="underline">ISO 9834-1</emphasis></emphasis></abbrev>
                  <author>
                     <orgname><emphasis role="bold"><emphasis role="underline">ISO</emphasis></emphasis></orgname>
                  </author>
                  <date><emphasis role="bold"><emphasis role="underline">2012</emphasis></emphasis></date>
                  <title><emphasis role="bold"><emphasis role="underline">Information technology - Open Systems Interconnection - Procedures for the operation of OSI Registration Authorities: General procedures and top arcs of the ASN.1 Object Identifier tree</emphasis></emphasis></title>
               </biblioentry>
            <biblioentry xml:id="biblio_ISO_15924">
               <abbrev>ISO 15924</abbrev>
               <author>
                  <orgname>ISO</orgname>
               </author>
               <date>2004</date>
               <title>Codes for the representation of names of scripts</title>
            </biblioentry>
            <biblioentry xml:id="biblio_JJ1017">
               <abbrev>JJ1017</abbrev>
               <author>
                  <orgname>Japan Medical Imaging and Radiological Systems Industries Association (JIRA) and Japanese Association of Healthcare Information Systems Industry (JAHIS)</orgname>
               </author>
               <title>Guidelines for HIS, RIS, PACS - Modality Data Communication on Scheduling, Billing, and Examination Records</title>
               <revhistory>
                  <revision>
                     <revnumber>3.0</revnumber>
                     <date>October 5, 2005</date>
                  </revision>
               </revhistory>
               <bibliosource>
                  <link xl:href="http://www.jira-net.or.jp/commission/system/04_information/files/JJ1017VER3_20051005.doc"/>
               </bibliosource>
            </biblioentry>
            <biblioentry xml:id="biblio_RadLex">
               <abbrev>RadLex</abbrev>
               <author>
                  <orgname>RSNA, Chicago</orgname>
               </author>
               <date>2006</date>
               <title>A Lexicon for Uniform Indexing and Retrieval of Radiology Information Resources</title>
               <bibliosource>
                  <link xl:href="http://www.radlex.org/"/>
               </bibliosource>
            </biblioentry>
            <biblioentry xml:id="biblio_RFC_1766">
               <abbrev>RFC 1766</abbrev>
               <author>
                  <orgname>IETF</orgname>
               </author>
               <date>March 1995</date>
               <title>Tags for the Identification of Languages</title>
               <bibliosource>
                  <link xl:href="http://tools.ietf.org/html/rfc1766"/>
               </bibliosource>
            </biblioentry>
            <biblioentry xml:id="biblio_RFC_3066">
               <abbrev>RFC 3066</abbrev>
               <author>
                  <orgname>IETF</orgname>
               </author>
               <date>January 2001</date>
               <title>Tags for the Identification of Languages</title>
               <bibliosource>
                  <link xl:href="http://tools.ietf.org/html/rfc3066"/>
               </bibliosource>
            </biblioentry>
            <biblioentry xml:id="biblio_RFC_4646">
               <abbrev>RFC 4646</abbrev>
               <author>
                  <orgname>IETF</orgname>
               </author>
               <date>September 2006</date>
               <title>Tags for Identifying Languages</title>
               <bibliosource>
                  <link xl:href="http://tools.ietf.org/html/rfc4646"/>
               </bibliosource>
            </biblioentry>
            <biblioentry xml:id="biblio_RFC_4647">
               <abbrev>RFC 4647</abbrev>
               <author>
                  <orgname>IETF</orgname>
               </author>
               <date>September 2006</date>
               <title>Matching of Language Tags</title>
               <bibliosource>
                  <link xl:href="http://tools.ietf.org/html/rfc4647"/>
               </bibliosource>
            </biblioentry>
            <biblioentry xml:id="biblio_RFC_5646">
               <abbrev>RFC 5646</abbrev>
               <author>
                  <orgname>IETF</orgname>
               </author>
               <date>September 2009</date>
               <title>Tags for Identifying Languages</title>
               <bibliosource>
                  <link xl:href="http://tools.ietf.org/html/rfc5646"/>
               </bibliosource>
            </biblioentry>
         </bibliodiv>
         <bibliodiv label="2.2" status="2" xml:id="sect_2.2">
            <title>BI-RADS® Terminology and Nomenclature</title>
            <para xml:id="para_d18e1feb-a054-42b8-b36c-708fc098117a">A portion of the terminology used within the Mammography CAD SR SOP Class and the Breast Imaging Report and Relevant Patient Information for Breast Imaging Templates is derived from BI-RADS®, a copyrighted lexicon of breast imaging terminology and nomenclature licensed by DICOM from the American College of Radiology.</para>
            <biblioentry xml:id="biblio_BIRADS">
               <abbrev>BI-RADS®</abbrev>
               <author>
                  <orgname>American College of Radiology, Reston, Virginia</orgname>
               </author>
               <date>1998</date>
               <edition>3.0</edition>
               <title>Breast Imaging Reporting and Data System Atlas</title>
               <bibliosource>
                  <link xl:href="http://www.acr.org/Quality-Safety/Resources/BIRADS"/>
               </bibliosource>
            </biblioentry>
         </bibliodiv>
         
         
         
         
         
         
         
         
         
         <bibliodiv label="2.15" status="2" xml:id="sect_2.15">
            <title>LOINC</title>
            <biblioentry xml:id="biblio_LOINC">
               <abbrev>LOINC</abbrev>
               <author>
                  <orgname>Regenstrief Institute, Indianapolis</orgname>
               </author>
               <date>2014</date>
               <title>Logical Observation Identifier Names and Codes</title>
               <bibliosource>
                  <link xl:href="http://loinc.org/"/>
               </bibliosource>
            </biblioentry>
            <para xml:id="para_e27b6af7-4129-4526-b250-e4ae290145a7">This product includes all or a portion of the LOINC® table, LOINC panels and forms file, LOINC document ontology file,
               and/or LOINC hierarchies file, or is derived from one or more of the foregoing, subject to a license from Regenstrief Institute, Inc.
               Your use of the LOINC table, LOINC codes, LOINC panels and forms file, LOINC document ontology file, and LOINC hierarchies
               file also is subject to this license, a copy of which is available at <link xl:href="http://loinc.org/terms-of-use"/>. The current complete
               LOINC table, LOINC Users' Guide, LOINC panels and forms file, LOINC document ontology file, and LOINC hierarchies file are
               available for download at <link xl:href="http://loinc.org/"/>. The LOINC table and LOINC codes are copyright © 1995-2014, Regenstrief Institute, Inc.
               and the Logical Observation Identifiers Names and Codes (LOINC) Committee. The LOINC panels and forms file, LOINC document
               ontology file, and LOINC hierarchies file are copyright © 1995-2014, Regenstrief Institute, Inc. All rights reserved.</para>
            <para xml:id="para_32d856f4-3e42-40ed-9391-01d4b4c28f31">The LOINC table (in all formats), LOINC panels and forms file, LOINC document ontology file, and LOINC hierarchies are provided "as is."
               Any express or implied warranties are disclaimed, including, but not limited to, the implied warranties of merchantability and fitness
               for a particular purpose.</para>
            <para xml:id="para_a4826285-c5a2-41f4-9613-a5ed6d6ad7ae">A small portion of the LOINC table may include
               content (e.g., survey instruments) that is subject to copyrights owned by third parties. Such content has been mapped to LOINC
               terms under applicable copyright and terms of use. Notice of such third party copyright and license terms would need to be
               included if such content is included.</para>
         </bibliodiv>
         <bibliodiv label="2.16" status="2" xml:id="sect_2.16">
            <title>UCUM</title>
            <biblioentry xml:id="biblio_UCUM">
               <abbrev>UCUM</abbrev>
               <author>
                  <orgname>Regenstrief Institute, Indianapolis</orgname>
               </author>
               <date>2013</date>
               <title>Unified Code for Units of Measure</title>
               <bibliosource>
                  <link xl:href="http://unitsofmeasure.org/"/>
               </bibliosource>
            </biblioentry>
            <para xml:id="para_10e9b576-9f74-4056-9dae-4ae188aa3b31">This product includes all or a portion of the UCUM table, UCUM codes, and UCUM definitions or is derived from it,
               subject to a license from Regenstrief Institute, Inc. and The UCUM Organization. Your use of the UCUM table,
               UCUM codes, UCUM definitions also is subject to this license, a copy of which is available at <link xl:href="http://unitsofmeasure.org/"/>.
               The current complete UCUM table, UCUM Specification are available for download at <link xl:href="http://unitsofmeasure.org/"/>. The UCUM
               table and UCUM codes are copyright © 1995-2013, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures (UCUM)
               Organization. All rights reserved.</para>
            <para xml:id="para_ea6907be-79f4-473d-9f1d-b831034b0247">The UCUM table (in all formats), UCUM definitions, and specification are provided "as is." Any express or implied warranties
               are disclaimed, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.</para>
         </bibliodiv>
         <bibliodiv label="2.18" status="2" xml:id="sect_2.18">
            <title>Point-of-Care Medical Device Nomenclature</title>
            <para xml:id="para_f3f65cde-1097-47c8-a6c5-7969e464556b">Extracts of ISO/IEEE 11073 reprinted by permission of IEEE, 3 Park Avenue, New York, NY 10016-5997 USA. Copyright by IEEE. 
               <link xl:href="http://standards.ieee.org/"/>.</para>
            <para xml:id="para_0795806a-ccd6-453e-be9f-253b4d0b43cd">Under license from IEEE, the term codes and descriptions of the ISO/IEEE 11073 Nomenclature are available at no cost through the Rosetta Terminology Mapping Management System of the U.S. National Institute of Standards and Technology. 
               <link xl:href="http://hit-testing.nist.gov:13110/rtmms/index.htm"/>
            </para>
            <biblioentry xml:id="biblio_ISO_IEEE_11073_10101">
               <abbrev>ISO/IEEE 11073-10101</abbrev>
               <author>
                  <orgname>ISO/IEEE</orgname>
               </author>
               <date>2004</date>
               <date/>
               <title>Health informatics - Point-of-care medical device communication - Nomenclature</title>
            </biblioentry>
            <biblioentry xml:id="biblio_ISO_IEEE_11073_10101a">
               <abbrev>ISO/IEEE 11073-10101a</abbrev>
               <author>
                  <orgname>ISO/IEEE</orgname>
               </author>
               <date>2015</date>
               <date/>
               <title>Health informatics - Point-of-care medical device communication - Nomenclature Amendment 1: Additional Definitions</title>
            </biblioentry>
            <biblioentry xml:id="biblio_ISO_IEEE_11073_10102">
               <abbrev>ISO/IEEE 11073-10102</abbrev>
               <author>
                  <orgname>ISO/IEEE</orgname>
               </author>
               <date>2015</date>
               <date/>
               <title>Health informatics - Point-of-care medical device communication - Annotated ECG - Nomenclature</title>
            </biblioentry>
         </bibliodiv>
         <bibliodiv label="2.19" status="2" xml:id="sect_2.19">
            <title>SNOMED Clinical Terms</title>
            <para xml:id="para_b12ff9ab-63d4-49c6-8b07-c9cb7157230b">This DICOM Standard incorporates SNOMED CT®, used by permission of the International Health Terminology Standards Development <foreignphrase xml:lang="en-GB">Organisation</foreignphrase> (IHTSDO). SNOMED CT®, was originally created by The College of American Pathologists (CAP). SNOMED CT® is a registered trademark of the International Health Terminology Standards Development <foreignphrase xml:lang="en-GB">Organisation</foreignphrase>, all rights reserved.</para>
            <para xml:id="para_b8c0e400-55f0-43b6-9bba-d98b7e1dc32d">The SNOMED CT terms used in this Standard (the SNOMED CT DICOM Subset) are the subject of a licensing agreement between NEMA and IHTSDO that allows the use of this defined subset in DICOM conformant applications without further license or payment of fee. Any use of SNOMED CT beyond the terms published in the DICOM Standard is subject to SNOMED CT licensing rules, which may include a fee. For further information about SNOMED CT licensing, go to <link xl:href="http://www.ihtsdo.org/snomed-ct/get-snomed-ct"/> or contact IHTSDO at <link xl:href="mailto:info@ihtsdo.org"/>.</para>
            <para xml:id="para_0fd01632-8e25-482c-9c6c-bc91416e68e6">This DICOM Standard incorporates various veterinary terms from the SNOMED CT VetSCT extension, used by permission of the Veterinary Terminology Services Laboratory (VTSL) (<link xl:href="http://vtsl.vetmed.vt.edu/"/>). These terms were previously included in SNOMED CT but have since been inactivated as moved elsewhere.</para>
            <biblioentry xml:id="biblio_SNOMED">
               <abbrev>SNOMED CT</abbrev>
               <author>
                  <orgname xml:lang="en-GB">International Health Terminology Standards Development Organisation (IHTSDO)</orgname>
               </author>
               <date/>
               <title>SNOMED CT Systematized Nomenclature of Medicine - Clinical Terms</title>
            </biblioentry>
         </bibliodiv>
      </bibliography>
   </section>
       
       <section label="8" status="1" xml:id="PS3.16_chapter_8">
      <title>Coding Schemes</title>
      <para xml:id="para_389c3616-61ec-4445-b4a6-bd40edcf86f9">
         <xref linkend="table_8-1" xrefstyle="select: label nopage"/> lists the coding schemes (and their designators) defined for use in DICOM; <xref linkend="table_8-2" xrefstyle="select: label nopage"/> lists the HL7v3 coding schemes referenced for use in DICOM. Additionally, any coding scheme may be used that has an entry in the HL7 Registry of Coding Schemes (HL7 v2 Table 0396, or the equivalent online registry), in which case the HL7 Symbolic Name shall be used as the value for the Coding Scheme Designator in DICOM, as long as it does not conflict with an entry 
    <xref linkend="table_8-1" xrefstyle="select: label nopage"/> and fits within the Value Representation of the DICOM Coding Scheme Designator (0008,0102) attribute. As specified in the HL7 v2 Table 0396, local or private coding schemes shall be identified by an alphanumeric identifier beginning with the characters "99".</para>
      <note>
         <orderedlist numeration="arabic">
            <listitem>
               <para xml:id="para_cc4a48c8-1017-4297-9ff1-d7d8ebb3ead3">An earlier version of this table was formerly contained in Annex D of <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>.</para>
            </listitem>
            <listitem>
               <para xml:id="para_52df67de-c471-4ad4-94da-5ac277cdebe3">See <olink targetdoc="PS3.3" targetptr="sect_8.2" xrefstyle="select: docname label quotedtitle"/> for further description.</para>
            </listitem>
            <listitem>
               <para xml:id="para_6461d581-c2c5-4dc8-9730-71116443a794">The Coding Scheme UIDs are provided for reference only; the normative specification of UIDs and their associated meaning is the responsibility of the coding scheme developer and/or HL7.</para>
            </listitem>
            <listitem>
               <para xml:id="para_b097aaca-ae03-4c14-93b8-30c08ff52f36">The HL7 registration of Coding Schemes is available at 
          <link xl:href="http://www.hl7.org/oid/index.cfm"/>.</para>
            </listitem>
            <listitem>
                  <para xml:id="para_5e031914-1c51-4e0e-9f1d-f47d3a51a92d">Publication of codes or references to coding schemes within DICOM does not constitute a grant of intellectual property rights to implementers. Use of some Coding Schemes may require a license, or purchase of the relevant coding scheme publication. Implementers should consult the relevant coding scheme publisher; see also <xref linkend="chapter_2" xrefstyle="template:Section %n"/>.</para>
               </listitem>
               <listitem>
                  <para><emphasis role="bold"><emphasis role="underline">The values of Coding Scheme Name (0008,0115), Coding Scheme Responsible Organization (0008,0116) and Coding Scheme Resources Sequence (0008,eee0), if available, may be used to fill the corresponding optional attributes of the Coding Scheme Identification Sequence (0008,0110) in the PS3.3 SOP Common Module.</emphasis></emphasis></para>
               </listitem>
         </orderedlist>
      </note>
      <table frame="box" label="8-1" rules="all" xml:id="table_8-1">
         <caption>Coding Schemes</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5ab47e20-56a9-4356-aa18-622a6f09a5a5">Coding Scheme Designator<emphasis role="bold"><emphasis role="underline"> (0008,0102)</emphasis></emphasis></para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_392f55a3-f29a-44ca-a7a9-89367a39f630">Coding Scheme UID<emphasis role="bold"><emphasis role="underline"> (0008,010C)</emphasis></emphasis></para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">Coding Scheme Name (0008,0115)</emphasis></emphasis></para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">Coding Scheme Responsible Organization (0008,0116)</emphasis></emphasis></para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">Coding Scheme Resources Sequence (0008,eee0)</emphasis></emphasis></para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_fe5d74ea-0181-4ede-aebd-1dd601771111">Description</para>
               </th>
            </tr>
         </thead>
         <tbody>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_3033a660-ccf2-408d-9c44-3bf1c38b57f3">ACR</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2a78e2af-579c-42bb-96d7-adf8a53d8be6">2.16.840.1.​113883.6.76</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ACR Index</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ACR</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_15d404c3-c3af-4cbe-bcca-ee209158af0c">ACR Index for Radiological Diagnosis Revised, 3<superscript>rd</superscript> Edition 1986</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_80f802aa-6a0d-49c3-8ef1-0fca7f010372">ASTM-sigpurpose</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_7eb949c2-012f-4af3-8f44-18e9cf645dac">1.2.840.10065.​1.12</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ASTM E 2084</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ASTM</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_bdb1db97-9bc5-48e5-a31a-a3e2deafbd25"><emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_ASTM_E2084_00"/><emphasis role="strikethrough">ASTM E 2084</emphasis></emphasis></emphasis> Signature Purpose codes (see Annex A1 of ASTM E 2084), ASTM Subcommittee E 31.20 Data and System Security for Health Information</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e71beb37-4ed2-4fba-a6fc-39c6bcc3b2b0">BARI</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_75a442b4-bbde-45bc-b73b-9648662eb889"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">BARI</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_b247fe92-4604-4fbe-b969-b6a7f8d3f902">Bypass Angiography Revascularization Investigation, Alderman, EL and Stadius, M, Coronary Artery Disease 1992, 3:1189-1207; endorsed by ACC/AHA Guidelines for Coronary Angiography, J Am Coll Cardiol 1999, 33:1791</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_15e30612-6273-4830-8cc0-8c23e966d5e1">BI</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_165af34b-52d2-49b6-96bf-d71498b60da7"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">BI-RADS</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ACR</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_668bc3e8-4701-41c8-8a8a-52585272c34f">ACR Breast Imaging Reporting and Data System <emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_BIRADS"/></emphasis><emphasis role="strikethrough">(BI-RADS®)</emphasis></emphasis>, Coding Scheme Version (0008,0103) is required; code values are section and paragraph identifiers within the publication where the code meaning is defined (e.g., "I.D.1", where I = Breast Imaging Lexicon, D = Special Cases, 1 = Tubular Density, as the code value for "Tubular Density").</para>
                  <note>
                     <para xml:id="para_113d2707-dbb6-4285-ae29-00f3a763ea78">In the HL7 registry, the abbreviation BI is assigned to a different coding scheme, specifically the Beth Israel problem list.</para>
                  </note>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1511f9ab-784b-4c8a-8547-8820c8a0ad41">C4</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a747298a-851a-46d7-8a4c-d5ac3a800858">2.16.840.1.​113883.6.12</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">CPT-4</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">AMA</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2753aeea-6f7b-4d93-b0e5-c5ad6ecc7e5b">American Medical Association's Current Procedure Terminology 4 (CPT-4)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_98859b86-2395-4d1c-bc68-5aab3ad4f276">C5</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d4a4a025-b4fc-4740-aaea-f40e6e037101">2.16.840.1.​113883.6.82</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">CPT-5</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">AMA</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_795bff8f-709f-4a71-a85f-d9de830904fc">American Medical Association's Current Procedure Terminology 5 (CPT-5)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1978a1af-6e87-48a5-bfaa-d187c6d6fa82">CD2</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_04307da3-eed3-4174-975a-46b950fdd5b0">2.16.840.1.​113883.6.13</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">CDT-2</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ADA</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d0f4d907-eaf9-47e7-9bef-42255bd77936">American Dental Association's (ADA) Current Dental Terminology 2 (CDT-2)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a1a516e3-15b0-4e06-9629-f34765f1ac0e">CTV3</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_eb92df37-8165-4371-9686-f94267f03261">2.16.840.1.​113883.6.6</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">Clinical Terms Version 3</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">UK NHS</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9b56d17b-de54-4954-a0ca-e237476e05ef">NHS Clinical Terms Version 3 (Read Codes)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_599bd347-2d3d-4c05-98ee-1848a70e6ddb">DCM</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8d6b9ab1-e4ba-43df-ae30-b17da46a48f8">1.2.840.10008.​2.16.4</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DICOM Controlled Terminology</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DICOM</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/chapter_D.html"/></emphasis></emphasis></para>
                  <para><emphasis role="bold"><emphasis role="underline">OWL: <link xl:href="ftp://medical.nema.org/medical/dicom/current/ontology/dcm.owl.zip"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_4754d612-1da1-45e4-89f2-8755322b5e6c">DICOM Controlled Terminology; PS3.16 Content Mapping Resource, Annex D<!--<xref linkend="chapter_D" xrefstyle="template:Annex %n"/>--> (Note that HL7 also specifies an OID of 2.16.840.1.​113883.6.31, but deprecates it in favor of 1.2.840.10008.​2.16.4).</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f2042a19-2050-4caf-87ef-c451a8a1b660">DCMUID</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6738fd82-0b76-4560-84fd-fed1e086b105">1.2.840.10008.​2.6.1</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DICOM UID Registry</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DICOM</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part06/chapter_A.html"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9a3be5c6-0bab-4de5-a285-6a2b9c0351a6">DICOM UID Registry</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_0bd4ce5d-1db0-4e09-b316-61a14acb1fe0">FMA</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_dcac1af0-b15a-4777-b7e9-5f0415d297ed">2.16.840.1.​113883.6.119</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">FMA</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">University of Washington, Seattle</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://sig.biostr.washington.edu/projects/fm/AboutFM.html"/></emphasis></emphasis></para>
                  <para><emphasis role="bold"><emphasis role="underline">OWL: <link xl:href="http://sig.biostr.washington.edu/share/downloads/fma/release/latest/fma.zip"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c7ca237e-be9c-4b73-9ce8-203c5fe4f80e">Digital Anatomist Foundational Model of Anatomy</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d78d9db4-fb87-4234-9a1e-96fb9e515a2c">HPC</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_772b78c9-de3e-4b7f-ab8e-a83128d75dc2">2.16.840.1.​113883.6.14</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_357d8991-81ac-493e-bef8-77dbc82812af">Healthcare Financing Administration (HCFA) Common Procedure Coding System (HCPCS)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e9fdce30-cc49-4d18-8fab-7ef3e031ddbc">I10</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5df40702-2f61-4f84-8cdb-9e41463eb92a">2.16.840.1.​113883.6.3</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ICD-10</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">WHO</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f3d3c8b7-2a3f-4d92-9c91-8ef4f08be1e9">International Classification of Diseases revision 10 (ICD-10)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_fbe49844-0fb1-421a-bc4a-459a3f614b58">I10P</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a4c28077-bdc7-470c-bb14-5f3635ce8bb5">2.16.840.1.​113883.6.4</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ICD-10-PCS</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">US DHHS CMS</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f5aa69de-ac30-44d4-a503-951e9138daea">ICD-10 Procedure Coding System (ICD 10 PCS)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_3b027c1b-fa9f-4316-a533-38e98f621177">I9</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_4868c6d7-1767-47e4-878c-236ae021608d">2.16.840.1.​113883.6.42</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ICD-9</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">WHO</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6c8e22e7-11d7-42d4-9a90-f5d69ce97a5f">International Classification of Diseases revision 9 (ICD-9)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_c7e37357-aec2-4a68-beb3-57f7e93fa269">I9C</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_93bc981f-5961-4ae8-b535-508a2e67cd68">2.16.840.1.​113883.6.2</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ICD-9-CM</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6783c5d9-254d-469c-965f-1d5b1d1d531c">International Classification of Diseases revision 9, with Clinical Modifications (ICD-9-CM)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_c11f058c-0368-495a-938f-a5fcacb08e85">IETF4646</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_dc0cf208-e2ef-48f2-a640-47e0c049afb4"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">RFC 4646</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">IETF</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://tools.ietf.org/html/rfc4646"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0f05c133-1eb5-4d2c-b94e-3e73f9f61ec5">
                     <xref linkend="biblio_RFC_4646"/>, Tags for Identifying Languages, The Internet Society (2005)</para>
                  <para xml:id="para_7444ff49-f95a-41ef-8ca1-efa4720ed318">
                     <xref linkend="biblio_RFC_4646"/> has been superceded by <xref linkend="biblio_RFC_5646"/>.</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d713a9b2-febe-4e9f-951f-f4a502efd1d7">ISO639_1</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a0b358aa-0556-449a-af96-399375da24df">2.16.840.1.​113883.6.99</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ISO 639-1</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ISO</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_433d6ab1-5902-453c-8e46-7f799ff853a7"><emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_ISO_639-1"/> </emphasis></emphasis>Two-letter language codes</para>
                  <note>
                     <para xml:id="para_593554e7-779b-46a9-b55e-d76d48024a5b">HL7 uses "ISO639-1" for the symbolic name, with a hyphen rather than an underscore</para>
                  </note>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_10afe20d-10da-4354-9cf5-0578b489fdcd">ISO639_2</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d1300dbc-800d-4549-93f0-ee2332bc6f45">2.16.840.1.​113883.6.100</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ISO 639-2</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ISO</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a5eb0d95-96f6-4827-8921-141dec3f63a9"><emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_ISO_639-2"/> </emphasis></emphasis>Three-letter language codes</para>
                  <note>
                     <para xml:id="para_f5e803b1-4ce7-4d81-ac76-2d2579cb398a">HL7 uses "ISO639-2" for the symbolic name, with a hyphen rather than an underscore</para>
                  </note>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_53415a20-74f3-4a13-8dcd-95a9f95d662f">ISO3166_1</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_78c7cece-432b-4bc1-aa89-a0b95145394e">2.16.1</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ISO 3166-1</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ISO</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_90266c3b-307a-4fc3-ae62-ec78e107c592">
                     <xref linkend="biblio_ISO_3166-1"/> alpha-2 Country Codes</para>
                  <note>
                     <para xml:id="para_17dd51c2-efb6-42ce-a433-6f6adb5809b9">HL7 uses "ISO3166-1" for the symbolic name, with a hyphen rather than an underscore</para>
                  </note>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_b1ebf28a-8244-442c-8015-7f6477f4123a">ISO5218_1</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f06f32db-87d3-4ebb-b947-e946c4915236"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ISO 5218-1</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ISO</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a4bd9806-f058-482c-8653-4f76a89339d8">Representation of Human Sexes (not used - see note)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_be132a7a-a4c9-40ce-b654-959c1bdaa79b">ISO_OID</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2a97313e-6666-449a-9701-fb2ebe57d829"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ISO OID</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ISO</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ef53f5d5-f9c4-455c-aca3-434c34a1b927"><emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_ISO_8824-1"/> </emphasis></emphasis>ISO/IEC 8824-1- Information Technology - Abstract Syntax 1 (ASN.1): Specification
                     of Basic Notation, and <emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_ISO_9834-1"/> </emphasis></emphasis> - Information technology - Open Systems
              Interconnection - Procedures for the operation of OSI Registration Authorities:
              General procedures and top arcs of the ASN.1 Object Identifier tree</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_af9582a8-03f8-4cb1-955f-20e0515e1817">ITIS_TSN</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_700b353a-ccf8-4564-85d2-90fc01ccae68">1.2.840.10008.​2.​16.​7</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ITIS TSN</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">ITIS</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://www.itis.gov"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_3ae5af2d-d44e-40b9-88e4-9959437822be">A Taxonomic Serial Number (TSN) is a unique, persistent, non-intelligent identifier for a scientific name in the context of the Integrated Taxonomic Information System (ITIS).</para>
                  <para xml:id="para_7a915408-bf48-4626-aa27-d1ca6b7de1e6"><emphasis role="bold"><emphasis role="strikethrough">See <link xl:href="http://www.itis.gov"/>.</emphasis></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_60695b70-1bb1-47fb-ada1-bdcc9888611e">LN</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_142b33e9-d458-4a20-91db-30e265a4d87f">2.16.840.1.​113883.6.1</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">LOINC</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">Regenstrief Institute</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://loinc.org/"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9c340b04-01a6-4093-b467-1e6aa6eb31fb"><emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_LOINC"/> </emphasis></emphasis>Logical Observation Identifier Names and Codes<emphasis role="bold"><emphasis role="strikethrough">, Regenstrief Institute</emphasis></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1fa22a09-5215-4bf5-ab84-90e65dba3959">MA</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_b1a97d93-cb0a-4139-beac-cba13087a19b">1.2.840.10008.​2.​16.​5</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">Adult Mouse Anatomy Ontology</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">The Jackson Laboratory</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://www.informatics.jax.org/searches/AMA.cgi?id=MA:0002405"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f465f3cc-1d97-469c-8c55-21e0fe467bc8"><emphasis role="bold"><emphasis role="strikethrough">The Adult Mouse Anatomy Ontology maintained by The Jackson Laboratory.</emphasis></emphasis></para>
                  <para xml:id="para_7947b5d9-2e8b-4ce2-9e37-a446c976ff88"><emphasis role="bold"><emphasis role="strikethrough">See <link xl:href="http://www.informatics.jax.org/searches/AMA.cgi?id=MA:0002405"/>.</emphasis></emphasis></para>
                  <para xml:id="para_7232de4a-f4ef-4f49-bb56-46effe260107">Hayamizu TF, Mangan M, Corradi JP, Kadin JA, Ringwald M. The Adult Mouse Anatomical Dictionary: a tool for annotating and integrating data. Genome Biology 2005;6(3):R29. doi:10.1186/gb-2005-6-3-r29. <link xl:href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1088948/"/>
                  </para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_73b60864-8ca0-4810-a354-562f9514ceab">MDC</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f35c7da2-055f-4d4d-a7f1-2194947e2417">2.16.840.1.​113883.6.24</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a1e7e245-a066-44a4-b48a-8a56e2290a4f">ISO/IEEE 11073 Medical Device Nomenclature, including all its subsections (<emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_ISO_IEEE_11073_10101"/>, <xref linkend="biblio_ISO_IEEE_11073_10101a"/>, <xref linkend="biblio_ISO_IEEE_11073_10102"/></emphasis><emphasis role="strikethrough">-10101, -10102</emphasis></emphasis>, etc.), encoded as decimal strings &lt;partition&gt;:&lt;element&gt;</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_b889e1ca-499b-46d9-9c07-54b066c680eb">MDNS</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_83a261fa-dc64-4363-86d1-f3cb95667036"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_794aacba-100b-411e-9475-21ba857c6f2b">Universal Medical Device (UMD) Nomenclature System</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e0247b36-d540-4c77-af02-524ca56707e7">MGI</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_4481161a-f48b-46df-92e3-95cc1d0feca6">1.2.840.10008.​2.​16.​8</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">MGI</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">The Jackson Laboratory</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://www.informatics.jax.org/mgihome/nomen/"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_fb70c93d-3fc1-489d-ba6b-e1549061b02f">The MGI ID from the Mouse Genome Initiative (MGI) nomenclature.</para>
                  <para xml:id="para_2901d5b9-0345-4757-919a-07f21170d33c"><emphasis role="bold"><emphasis role="strikethrough">See <link xl:href="http://www.informatics.jax.org/mgihome/nomen/"/>.</emphasis></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a6536c91-84bf-42d8-8f32-dede9c39ba78">MSH</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1d35251c-c98c-420b-82cf-9badd1a6136c">2.16.840.1.​113883.6.177</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">MeSH</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">NLM</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://www.nlm.nih.gov/mesh/meshhome.html"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_27df907a-7624-482f-867b-64d665ca0b91">US National Library of Medicine (NLM) Medical Subject Headings (MeSH)</para>
                  <para xml:id="para_f09de80d-dc90-4166-841e-8ee2c753f516"><emphasis role="bold"><emphasis role="strikethrough">See <link xl:href="http://www.nlm.nih.gov/mesh/meshhome.html"/>.</emphasis></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_504db674-aaf8-45ea-97f2-7b3c56c0032c">NBD</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_23a2147e-724f-41f6-a7d6-82c5bfe7958e">2.16.840.1.​113883.15.2</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_da1651b5-2860-407f-9b50-e4920efcb365">NASPE/BPEG Defibrillator Code</para>
                  <para xml:id="para_2ad2417f-4cab-45c4-8713-e2688f662279">Bernstein AD, et al."The NASPE/BPEG Defibrillator Code" 
            <emphasis role="italic">PACE</emphasis>, 16:1776-1780, 1993</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_cd9a0912-e429-4aeb-821c-077b3ec7333f">NBG</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6d34be40-a1b6-4e38-8ac0-3075bd9ac0fb">2.16.840.1.​113883.15.3</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <!-- zero width spaces in rendered link before hyphens are to avoid too wide a table cell -->
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://www.hrsonline.org/Practice-Guidance/Clinical-Guidelines-Documents/2002-The-Revised-NASPE-BPEG-Generic-Code-for-Antibradycardia-AdaptiveRate-and-Multisite-Pacing">http://www.hrsonline.org/Practice-​Guidance/Clinical-​Guidelines-​Documents/​2002-​The-​Revised-​NASPE-​BPEG​-​Generic-​Code-​for-​Antibradycardia-​​AdaptiveRate-​and-​Multisite-​Pacing</link></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d31e4c28-22a7-467a-b56b-bfde48ce43a9">NASPE/BPEG Generic Pacemaker Code (2000)</para>
                  <para xml:id="para_e5fc8012-d679-46f7-9cb0-362c9c4d0bae">Bernstein AD, et al."The Revised NASPE/BPEG Generic Code for antibradycardia, adaptive-rate, and multisite pacing." 
              <emphasis role="italic">Pacing Clin Electrophysiol.</emphasis>, 25:260-264, 2002</para>
                  <para xml:id="para_21e5be38-844f-461a-ba4e-c987063a592d">See <link xl:href="http://www.hrsonline.org/Practice-Guidance/Clinical-Guidelines-Documents/2002-The-Revised-NASPE-BPEG-Generic-Code-for-Antibradycardia-AdaptiveRate-and-Multisite-Pacing">http://www.hrsonline.org/Practice-​Guidance/Clinical-​Guidelines-​Documents/​2002-​The-​Revised-​NASPE-​BPEG​-​Generic-​Code-​for-​Antibradycardia-​​AdaptiveRate-​and-​Multisite-​Pacing</link>.</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_16f49365-17ef-4fec-bbb0-f0552ee44a9d">NCDR</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_17e93137-0523-448c-99b5-4788609c1666"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5844c08f-558c-4a35-9a26-176819bbcf21">American College of Cardiology National Cardiovascular Data Registry™ Cath Lab
              Module Version 1.1, 1997; Version 2.0b, 1999</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d5493b38-f911-4441-9a8e-8a0fc9ea3f09">NCIt</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a1acbf1b-d06b-473d-b139-b6dc1819ba8c">2.16.840.1.​113883.3.26.1.1</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">NCI Thesaurus</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">NCI</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://ncit.nci.nih.gov/"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_693dcc8a-a727-4895-803d-2cae6dd21543"><emphasis role="bold"><emphasis role="strikethrough">NCI Thesaurus. See <link xl:href="http://ncit.nci.nih.gov/"/></emphasis></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_8bcbcd97-397b-43fc-ad71-196e04796f6c">NEU</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1a520082-c334-4fb9-ae1f-bb6bb759ca88">2.16.840.1.​113883.6.210</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">NeuroNames</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <!-- zero width spaces in rendered URL for table width-->
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://braininfo.rprc.washington.edu/aboutBrainInfo.aspx#NeuroNames">http://braininfo.​rprc.​washington.​edu​/aboutBrainInfo.aspx​#NeuroNames</link></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_68d52c23-c1a6-4abc-815d-b3fa93857b4f"><emphasis role="bold"><emphasis role="strikethrough">NeuroNames. </emphasis></emphasis>The numeric brainInfoID is used as the code value. See <emphasis role="bold"><emphasis role="strikethrough"><link xl:href="http://braininfo.rprc.washington.edu/aboutBrainInfo.aspx#NeuroNames">http://braininfo.​rprc.​washington.​edu​/aboutBrainInfo.aspx​#NeuroNames</link></emphasis></emphasis>
                  </para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f165e510-0f91-4a97-a0d8-49b0468c8c23">NICIP</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6a0edf9f-d128-461f-9fb5-76f4784b4d93">2.16.840.1.​113883.2.1.​3.2.4.21</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">NICIP</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">UK NHS</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <!-- zero width spaces in rendered URL for table width-->
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="https://digital.nhs.uk/article/1108/National-Interim-Clinical-Imaging-Procedure-NICIP-Code-Set">https://digital.​nhs.​uk/​article/​1108/​National-​Interim-​Clinical-​Imaging-​Procedure-​NICIP-​Code-​Set</link></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_453a5aed-5775-4bc6-a084-62fbb7165baf">UK National Health Service National Interim Clinical Imaging Procedures (NICIP) Short Code (e.g., "CCHAPC" for CT Thorax abdomen pelvis with contrast)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f2ae24de-9946-4ac1-a89f-4430317877e3">NPI</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_afd0f233-8568-417a-b2a8-07e56250fd3c"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_b50d09ca-2f56-4801-91c6-7bc203e53a7c">HCFA National Provider Identifier</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_629af3a9-e55a-47e5-8798-6ea4888f32c6">POS</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_7b6db951-8a60-4460-91ac-c50401c09cf7">2.16.840.1.​113883.6.50</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9adc41fd-1975-4e9a-b165-8c2f1c4d2922">HCFA Place of Service (POS) Codes for Professional Claims</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_b0155bc8-ece6-4b3b-9d35-14f23a64233d">PUBCHEM_CID</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c3f8d514-1de7-4cab-8dba-8976f8d17652">1.2.840.10008.​2.​16.​9</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">PubChem</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">NCBI</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <!-- zero width spaces in rendered URL for table width-->
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="https://pubchem.ncbi.nlm.nih.gov/">https://pubchem.​ncbi.​nlm.​nih.​gov/</link></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_61ee0d9a-f361-4ed9-be35-da9e78388617">US National Center for Biotechnology Information (NCBI) PubChem Compound CID.</para>
                  <para xml:id="para_24c1594e-9160-4086-94dc-95dabea0a789"><emphasis role="bold"><emphasis role="strikethrough">See <link xl:href="https://pubchem.ncbi.nlm.nih.gov/">https://pubchem.​ncbi.​nlm.​nih.​gov/</link>.</emphasis></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f568450e-c147-41e3-ba6d-057ffd233e89">RADLEX</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e40c4197-28a1-48bb-a57b-7b2d208b797c">2.16.840.1.​113883.6.256</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">RadLex</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">RSNA</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://www.radlex.org/"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_812b50d0-596c-4b0d-8ea7-c41c6ae0d10d"><emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_RadLex"/></emphasis><emphasis role="strikethrough">RadLex</emphasis></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e8065511-9b85-4895-8790-d6c8d6fda5bb">RFC3066</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_3e655ed7-d7cd-429f-b493-bafe912f4c3c">2.16.840.1.​113883.6.121</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">RFC 3066</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">IETF</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://tools.ietf.org/html/rfc3066"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e5b55166-d6c6-4881-9bc3-087dfd8c8ecd">
                     <xref linkend="biblio_RFC_3066"/>, Tags for the Identification of Languages, Internet Engineering Task Force</para>
                  <note>
                     <para xml:id="para_56c2fbde-d413-4886-9e8d-4fefb339663f">HL7 uses "IETF3066" for the symbolic name.</para>
                     <para xml:id="para_079814ee-27a5-4e89-aee3-ff7e777ae6b7">
                        <xref linkend="biblio_RFC_3066"/> has been superseded by <xref linkend="biblio_RFC_4646"/>, which in turn has been superceded by <xref linkend="biblio_RFC_5646"/>.</para>
                  </note>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_da712a7d-0164-447d-b754-9fa0fa769236">RFC5646</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_72ce4955-af4d-4b75-a969-4e7144bba83d">2.16.840.1.​113883.6.316</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">RFC 5646</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">IETF</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://tools.ietf.org/html/rfc5646"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_deefe804-61ba-4ee3-ad2c-61ddabc053ee">
                     <xref linkend="biblio_RFC_5646"/>, Tags for Identifying Languages, The Internet Society (2009)</para>
                  <note>
                     <para xml:id="para_a250af59-06d0-4ee3-ba55-3edc3be81b08">The HL7 OID Registry specifies "rfc5646", not "ietf5646", as the Desired Symbolic Name (inconsistent with the pattern used for <xref linkend="biblio_RFC_4646"/>).</para>
                     <para xml:id="para_a9ca860c-1ce1-42bc-89ad-7b9d54c358d5">
                        <xref linkend="biblio_RFC_5646"/> constitutes one part of IETF Best Current Practice BCP 47 Tags for Identifying Languages, which also includes <xref linkend="biblio_RFC_4647"/> Matching of Language Tags; <xref linkend="biblio_RFC_4647"/> is not relevant in this context.</para>
                  </note>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_8c75b6c8-dd44-4f56-b047-011d42e901bd">99SDM</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_dfa2cd1d-3ad7-4267-b802-2dfe5adc6ba8">2.16.840.1.​113883.6.53</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">SDM</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DICOM</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0bab8e13-07fe-45d8-8b35-0860a1451ee1">SNOMED DICOM Microglossary (Retired) (see <xref linkend="sect_8.1" xrefstyle="select: label"/>)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_534e45a1-c802-474d-af08-87a3a04fe98c">SCPECG</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e50f5cea-99e3-406a-b1a8-87e7b189d7c7"/>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_40344a84-ec0b-41d4-a680-4054fd83aab3">Standard Communications Protocol for Computer-Assisted Electrocardiography, Draft proposal for ISO Standard, AAMI, Revision 1.3</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_95678825-fc6b-43b0-a514-07b8da6dfa2d">SNM3</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_dc58ae7b-2aea-4758-9b3a-8f72844b042f">2.16.840.1.​113883.6.51</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">SNOMED V3</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">SNOMED International</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://www.snomed.org/"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_683ca2a1-14b7-42b0-8fa8-9f1b93bba5f4">SNOMED International Version 3 (see <xref linkend="sect_8.1" xrefstyle="select: label"/>)</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_14221246-dd6c-443c-9254-93c519229893">SCT</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9cada316-7eaa-4bc6-9fe4-bac5852564f9">2.16.840.1.​113883.6.96</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">SNOMED CT</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">SNOMED International</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://www.snomed.org/"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6af3c4f1-a28f-407c-8398-78a86339f3f0"><emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_SNOMED"/></emphasis><emphasis role="strikethrough">SNOMED-CT</emphasis></emphasis>, using the CT code values</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_331a27e9-511e-4aa2-afa2-7ec9e085198f">SRT</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_958d40a2-2210-4d39-83c8-27416ffee045">2.16.840.1.​113883.6.96</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">SNOMED CT</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">SNOMED International</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://www.snomed.org/"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5980e9f5-eb65-4735-aae4-803ef0cdb96f"><emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_SNOMED"/></emphasis><emphasis role="strikethrough">SNOMED-CT</emphasis></emphasis>, using the "SNOMED-RT style" code values (see <xref linkend="sect_8.1" xrefstyle="select: label"/>)</para>
                  <note>
                     <para xml:id="para_1f97db3e-52a8-4346-8731-3dbfe1ac40e9">HL7 uses "SNM" for the symbolic name.</para>
                  </note>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_01ce0631-db91-4b11-a0ab-a17dec9fa9a8">UBERON</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_63206896-b9a4-4633-bfd5-643d885325de">1.2.840.10008.​2.​16.​6</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">UBERON</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://uberon.org/"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e1d426be-e4f5-4e21-94f2-a57fc06531c4">The Uberon ID from the Uberon integrated cross-species ontology covering anatomical structures in animals.</para>
                  <para xml:id="para_fc80f1c8-aa13-4d87-8e93-d2c08856d2d9"><emphasis role="bold"><emphasis role="strikethrough">See <link xl:href="http://uberon.org/"/>.</emphasis></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_b127a1e8-a339-42d6-9140-52256155b774">UCUM</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_4c10ffdb-01f4-4cdc-b994-cdb729c978cc">2.16.840.1.​113883.6.8</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">UCUM</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">Regenstrief Institute</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://unitsofmeasure.org/ucum.html"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_04f074ac-982c-4db0-997c-151a8fd60267"><emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_UCUM"/> </emphasis></emphasis>Unified Code for Units of Measure</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_c3a217a2-5f91-43cb-9396-c4dc830651c0">UMLS</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e4dde7df-313d-4724-b227-9c042fea2560">2.16.840.1.​113883.6.86</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">UMLS</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">NLM</emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline">DOC: <link xl:href="http://www.nlm.nih.gov/research/umls/"/></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_33a3c53f-fe4d-49a4-b113-65dd2e976be5">UMLS codes as CUIs making up the values in a coding system</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_aa1a415a-c0ab-4801-ad2b-74b74f0079d7">UPC</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d324c526-e0e3-4e13-bd86-54b9a03095db">2.16.840.1.​113883.6.55</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8f6e149c-c963-4b1c-b80d-6e49ee9263f5">Universal Product Code - Universal Code Council</para>
               </td>
            </tr>
         </tbody>
      </table>
      <note>
         <para xml:id="para_19bc0566-5674-4e32-b8e2-dc7f0f83c809">Coding Scheme Designator ISO5218_1 was improperly specified in earlier editions of the standard. The codes attributed to that coding scheme have been added to the DICOM Controlled Terminology, and thus all references to coding scheme ISO5218_1 should be considered equivalent to coding scheme DCM.</para>
      </note>
      <table frame="box" label="8-2" rules="all" xml:id="table_8-2">
         <caption>HL7v3 Coding Schemes</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_30f42a62-94b2-439f-83fd-51be1ff116d9">Coding Scheme Designator</para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_2abf40ce-26fa-4d4c-9fb6-103b8797463e">Coding Scheme UID</para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a871cb75-d470-47fd-bfd8-6ddf9d8a8fde">Description</para>
               </th>
            </tr>
         </thead>
         <tbody>
            <tr valign="top">
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f499480f-743c-4092-b8fd-f93f4082c82a">ActCode</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_67d78402-0fe9-44d8-892b-6a23b5db5b77">2.16.840.1.​113883.5.4</para>
               </td>
               <td align="left" colspan="1" rowspan="1"/>
            </tr>
            <tr valign="top">
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6e2e6d3e-86dc-48ec-b7b6-ffefcc08698d">ActPriority</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_caeaad32-06d1-483b-9411-6ec9f575cf98">2.16.840.1.​113883.5.7</para>
               </td>
               <td align="left" colspan="1" rowspan="1"/>
            </tr>
            <tr valign="top">
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_08277289-5b60-45db-b915-75ec605cbb2a">AdministrativeGender</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ee5ae8f6-f999-4f65-b492-756210621599">2.16.840.1.​113883.5.1</para>
               </td>
               <td align="left" colspan="1" rowspan="1"/>
            </tr>
            <tr valign="top">
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a89c854d-65d1-469f-9a8f-edfb81c62b16">mediaType</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2d859441-19f0-43ae-9d36-e2f3d15b7caf">2.16.840.1.​113883.5.79</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5f21e636-19dc-484b-bad8-7f895e03d419">
                     <link xl:href="http://www.ietf.org/rfc/rfc2046.txt">RFC2046</link>
                  </para>
               </td>
            </tr>
            <tr valign="top">
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_3e4b9535-deaf-4fd8-b4e1-3714462b8946">NullFlavor</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0f4e67cf-e56b-4510-a4af-d7f73b7a73d0">2.16.840.1.​113883.5.1008</para>
               </td>
               <td align="left" colspan="1" rowspan="1"/>
            </tr>
            <tr valign="top">
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_bfcbd2e3-af14-492a-b849-2feef3607ea7">ObservationInterpretation</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_3a819bf0-e0a6-4991-9337-fe0e45e5a497">2.16.840.1.​113883.5.83</para>
               </td>
               <td align="left" colspan="1" rowspan="1"/>
            </tr>
            <tr valign="top">
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ab4131e3-f479-4b74-9f51-6d25fd3f6f8b">Confidentiality</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a032ddb3-2999-4efd-ac20-c77c02ed317c">2.16.840.1.​113883.5.25</para>
               </td>
               <td align="left" colspan="1" rowspan="1"/>
            </tr>
            <tr valign="top">
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9908c4fc-bae0-4d68-af3e-a135732fe03a">ParticipationType</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5473bba5-b724-476b-be0b-63ab438214ef">2.16.840.1.​113883.5.90</para>
               </td>
               <td align="left" colspan="1" rowspan="1"/>
            </tr>
         </tbody>
      </table>
          
          <section label="8.1" status="2" xml:id="sect_8.1">
             <title>SNOMED</title>
             <para xml:id="para_1dd06a96-c0aa-48a0-a6fc-983137075753">SNOMED (the Systematized Nomenclature of Medicine) is the preferred coding system within DICOM for anatomy, clinical findings, procedures, pharmaceutical/biologic products (including contrast agents), and other clinical terms.</para>
             <para xml:id="para_e7a4d291-64b7-4a51-960d-510224c1f431">SNOMED has had various versions, including SNOMED International (Version 3), which was issued in 1993 and revised through 1998, SNOMED Reference Terminology, the successor to SNOMED 3 that was published between 1999 and 2001, and SNOMED Clinical Terms, which has been the name since 2002. The coding scheme is fully backward-compatible across SNOMED 3, SNOMED-RT, and SNOMED CT. SNOMED CT introduced a solely numeric set of codes (ConceptID) in addition to the former alphanumeric codes (SnomedID), but all SNOMED terminology concepts have both a numeric and an alphanumeric code.</para>
             <para xml:id="para_5315275e-e297-49ba-aaec-ff45e85ca583">In previous editions of the DICOM Standard, the following Coding Scheme Designators were used for SNOMED codes in DICOM:</para>
             <itemizedlist>
                <listitem>
                   <para xml:id="para_6353285d-08a1-43bd-95d4-833dd827d183">"99SDM", denoting the provisional SNOMED DICOM Microglossary</para>
                </listitem>
                <listitem>
                   <para xml:id="para_61804987-e659-4cdf-a3d5-4639518f23c4">"SNM3", denoting SNOMED International (Version 3)</para>
                </listitem>
                <listitem>
                   <para xml:id="para_d8a8a9e4-e350-4803-84ad-e8e33a845c69">"SRT", originally denoting SNOMED-RT</para>
                </listitem>
             </itemizedlist>
             <para xml:id="para_d8731612-2d84-4d7e-83c1-e9938a25e256">All uses of SNOMED coded terms in DICOM are now indicated by the Coding Scheme Designator "SRT", identifying them as SNOMED CT terms using the "SNOMED-RT style" alphanumeric code values, with some exceptions:</para>
             <itemizedlist>
                <listitem>
                   <para xml:id="para_c7dc619a-16cb-45fd-8a7e-d6fd20d0d0a0">The <olink targetdoc="PS3.3" targetptr="sect_A.5" xrefstyle="select: docname quotedtitle"/> and <olink targetdoc="PS3.3" targetptr="sect_A.21" xrefstyle="select: docname quotedtitle"/> in some code sequences require the Coding Scheme Designator "99SDM" as an Enumerated Value (see <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>).</para>
                </listitem>
                <listitem>
                   <para xml:id="para_845245ec-79bc-45ac-aa5c-5c88d77246b9">The Mammography View Codes of CID 4014 "View for Mammography"<!--<xref linkend="sect_CID_4014" xrefstyle="select: labelnumber quotedtitle nopage"/>--> and CID 4015 "View Modifier for Mammography"<!--<xref linkend="sect_CID_4015" xrefstyle="select: labelnumber quotedtitle nopage"/>--> may use the Coding Scheme Designator "SNM3" for implementation adherence to regulatory approvals.</para>
                </listitem>
             </itemizedlist>
             <para xml:id="para_7192aa44-28fd-494a-af81-f5a31fc1dd5c">Consequently, when a Coding Scheme Designator of "99SDM" or "SNM3" is encountered, it shall be treated as equivalent to "SRT" for the purpose of interpreting the Code Value.</para>
             <note>
                <para xml:id="para_229e3e38-a9b9-4de3-8dc4-0c9396ff133e">"SRT" as a coding scheme designator is used only in the DICOM Standard. HL7v2 did not standardize a coding scheme designator for SNOMED-RT.</para>
             </note>
             <para xml:id="para_78ae552f-5678-4603-a972-9ad31ec0672f">When interoperating with systems that use SNOMED CT codes obtained from a source other than the DICOM Standard, Application Entities may receive Code Sequences with a Coding Scheme Designator of "SNOMED-CT" and a numeric ConceptID code. It is the responsibility of such Application Entities to convert any such codes to the alphanumeric SnomedID with Coding Scheme Designator "SRT" for use in DICOM objects and services.</para>
             <section label="8.1.1" status="3" xml:id="sect_8.1.1">
                <title>Use of SNOMED Anatomic Concepts</title>
                <para xml:id="para_f3c6fc76-0433-45e7-b1b3-5bc08f55ca77">In general, DICOM uses the anatomic concepts with the term "structure", rather than with the term "entire". This is an important distinction in SNOMED. "Entire" is a child concept to "structure", has a more restricted meaning, and typically is used in conjunction with treatments (e.g., "excision of 
                   <emphasis role="italic">entire</emphasis>right kidney"). It is used in distinction to other sibling children of the parent concept that may identify parts of the parent anatomic feature. Since imaging typically targets both the anatomic feature and the area around it, or sometimes just part of the anatomic feature, DICOM usually uses "structure" concepts that are more inclusive than the "entire" concepts.</para>
             </section>
          </section>
          <section label="8.2" status="2" xml:id="PS3.16_sect_8.2">
             <title>ISO_OID</title>
             <para xml:id="para_627cef9d-16af-428c-8c37-e4bb111a68e9"><emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_ISO_8824-1"/></emphasis><emphasis role="strikethrough">ISO 8824</emphasis></emphasis> and <emphasis role="bold"><emphasis role="underline"><xref linkend="biblio_ISO_9834-1"/></emphasis><emphasis role="strikethrough">ISO 9834-1</emphasis></emphasis> are the standards defined for the generation of object identifiers that are used as DICOM Unique Identifiers (see <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>), can also serve as a general mechanism for identifying organizations and objects defined by those organizations.</para>
             <para xml:id="para_efad7c58-da8d-4d03-8f4d-6fd398862e30">When the Coding Scheme Designator is ISO_OID, the Code Value shall be the numeric (dot delimited) form of a valid object identifier.</para>
             <para xml:id="para_947ff1f3-3ba7-4929-826d-1fbea2bee246">A repository of known existing object identifiers can be found at 
                <link xl:href="http://www.oid-info.com/index.htm"/>. For example:</para>
             <itemizedlist>
                <listitem>
                   <para xml:id="para_fc0d7d42-c92d-4f2d-bce5-0ea3e730a974">the ISO 9834-1 assigned numeric object identifier for the country France, is "1.0.3166.2.2.1.250" (since ISO 3166 defines a means for maintaining country codes using object identifiers)</para>
                </listitem>
                <listitem>
                   <para xml:id="para_9397a115-dfb7-4835-b369-d6760429a77b">the object identifier for the RIPEMD-160 cryptographic hash function is "1.0.10118.3.0.49"</para>
                </listitem>
                <listitem>
                   <para xml:id="para_60a3c031-a810-424a-8f2f-2ceb95cd9253">the object identifier for the HL7 V2 table of codes for marital status is "2.16.840.1.113883.12.2"</para>
                </listitem>
             </itemizedlist>
             <para xml:id="para_b4928b64-885c-4e37-98a0-84b0a6c3f8dc">The re-use of object identifiers for existing concepts that do not have an alternative more appropriate coding scheme compatible with DICOM provides a mechanism to avoid defining new codes. For example, HL7 assigned object identifiers can be found at 
                <link xl:href="http://www.hl7.org/oid/index.cfm"/>.</para>
             <para xml:id="para_eb7134b8-77cc-451d-a0ea-c63f742272e9">Though the intent of ISO_OID is to define organizational roots for the hierarchical assignment of object identifiers, and not specifically to identify organizations per se, the organizational root values can be construed as identifying the organization. For example, the DICOM Standards Organization itself can be identified by the value "1.2.840.10008". See also CID 5002 "Organizations"<!--<xref linkend="sect_CID_5002" xrefstyle="select: labelnumber quotedtitle nopage"/>-->.</para>
          </section>
          
   </section>
         
    </chapter>
</book>