<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1579</title>
    <subtitle>Clarify explanation of heading conditions in Measurement template</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
           <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>Sep 2016 Voting Packet</para></td>
           </tr>
           <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>2016/05/25</para></td>
           </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>Jörg Riesmeier</para><para><link
                xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:mail@jriesmeier.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>2016/01/07</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1578</para></td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Clarify explanation of heading conditions in Measurement template</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                  <para>The informative text explaining the conditions for the headings is confusing and contradictory. Clarify.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
      
         <section label="TID 1500" status="3" xml:id="sect_TID_1500">
            <title>Measurement Report</title>
            <table frame="box" label="TID 1500" rules="all" xml:id="table_TID_1500">
               <caption>Measurement Report</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7f96ef72-3739-4709-a6f5-d3c609e4ec05"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_eb663436-d709-454e-ac93-98682212c9f0">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6142a93b-0f6d-44a4-8494-fc3299ba7c21">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_81a6fa58-162c-4816-971a-d0a224744ee1">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_97622db7-889d-46d0-a1c0-605bfed0f4c7">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_feb517dd-7464-42f5-9f1d-496753de6be4">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_220e6ae8-5f33-4f58-b426-f41cd8fd2bf4">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9af3785d-8f23-4d07-809d-5639784468c9">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_80f6672b-b0af-4725-adc3-e4e8c7e83695">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c8db842c-0b5d-4809-b5f7-5414422e2aca">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_acd4ceff-ae4f-4e83-bc99-27092e318603">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bf056d16-e8ba-482d-8ddc-d5113320cf49">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3ff0b318-d282-4163-9f2e-fdac666bad46">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9a55999e-9b7a-4082-a550-f4cea95ab6e0">EV <link linkend="DCM_126010" xrefstyle="select: nopage">(126010, DCM, "Imaging Measurements")</link></para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6b3b7a9e-eb99-4f87-a6e4-6cc3e8513983">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_34df0c4c-cfa8-4c66-a27d-de2b8d9e3f85">C</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_37a3cb9d-3117-401d-b28a-44ba2e697fc7">IF row 10 and 12 are absent</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_db8f2474-f267-4c5a-a382-e6c9459b921d"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_96d6cfbb-9f8d-4203-92f0-dc6f05c2d0a8">7</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6ef2d231-13a5-4959-a821-9506f815bff7">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3f15deab-dd23-4d60-83de-dd6a73b90078">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7ce9f59e-0b11-4f3a-aa05-a88e1aa9c1ae">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_77bd714c-3790-436e-8fde-280daf9850b5">DTID 1410 <!--<xref linkend="sect_TID_1410" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a9103603-6261-4637-b46b-fa22134536fe">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_15f776e2-a5af-4ee4-8902-8d861d3932b7">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d25704ea-5734-4683-8a36-210409afacf8"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a87b6e4f-bced-4eb7-85ca-72f7b53d423c">$Measurement = BCID 7469 <!--<xref linkend="sect_CID_7469" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                        <para xml:id="para_378db2d7-b6b1-4bd5-bd55-3ecc1936deb9">$Units = BCID 7181 <!--<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                        <para xml:id="para_99508cbb-2bee-4f5b-8816-1d3495eccb3c">$Derivation = BCID 7464<!--<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                        <para xml:id="para_d653b285-fe19-47d0-9b09-d0cec3ff9359">$Method = BCID 6147 <!--<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f35f1012-6565-4615-94b4-a578329d628c">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8ccf6dc7-6bfa-4c00-a480-e01762c81728">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bddc1cb2-753b-4cfb-afb9-4e7d0a9a5b88">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_20defab9-20a6-4f11-8d8d-5dc3d112bce6">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_41dd250a-8b5b-4dbf-8841-b031757426a3">EV <link linkend="DCM_126011" xrefstyle="select: nopage">(126011, DCM, "Derived Imaging Measurements")</link></para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_22a0c72b-ee47-4b01-8193-4fccee14c0f8">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_86f3c834-9d4e-457b-9727-a65324c488fe">C</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_30d76f5b-1438-404c-8012-2bfb78dc0bc3">IF row 6 and 12 are absent</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_87acdb58-5f9a-4c02-b01a-4e3975a65b68"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td>11</td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e19fbf7f-6880-43dc-8a0e-e04dded8b987">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_94f538e7-d77b-45ac-8745-7926463117b8">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6edc5ae3-633e-4b7b-8ed2-8fda35a733bf">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e0869a6-aba4-443b-8a8a-0a9a242b084e">DTID 1420 <!--<xref linkend="sect_TID_1420" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6ebd888e-3d5f-481e-8cc2-d27a627f050c">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2285bebe-5845-45ac-ba0b-e496db27fc79">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8d908f8c-a89b-42f5-82c8-76b4377d81df"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b8f4b122-190c-4172-ab6b-1e3ef7dbf2fd"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e6303ba8-e73d-47e2-b3f3-a8ef763670e2">12</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_46385195-5342-4453-bea9-10a9a5e847c4">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e920f388-7676-4925-95be-ea982490ed11">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_25092981-319c-409c-9dd1-9ea2999ec332">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7c6a4a43-d145-4388-bdef-847876a32127">EV (C0034375, UMLS, "Qualitative Evaluations")</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ab8cbaaf-8524-43e5-b0ce-aa67fde75001">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_bebf19ad-7f8e-4877-a86c-b22e858a021f">C</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1a7df7bb-aa04-4abf-b4b1-d3a796e31a9d">IF row 6 and 10 are absent</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ce6d2583-fcb3-407b-8163-f8af1ee4f1ae"/>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2ae96bcf-1778-4a2f-8f33-2f300c0db2b0">13</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5d80579d-2158-4e3f-9c06-060995308632">&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_65242578-3b90-4010-b8b5-e1105e04fef6">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b0ae5825-e6b1-4dbb-8154-6e53132b2fe5">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_97685e5a-e9cd-47b1-a9ee-c3573027dbb1"/>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7072bd7f-1dbb-44a9-a126-90f9eb514a70">1-n</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_25ba4a6a-6743-441c-bb3f-fe9a38515976">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4cc22382-35ea-4094-b218-49471bb2254a"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_38da5bd9-00b5-44fb-b597-168e198ee097"/>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_868f2065-cd1a-426f-a9fe-19f831d32718">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c81883d4-3a76-4f4a-8408-9ed9e49c2b75">Rows 6, 10, 12</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8d3926d3-2967-4b80-9371-98b72ca99b65">The conditions require that <emphasis role="bold"><emphasis role="strikethrough">all except</emphasis><emphasis role="underline">at least</emphasis>
                </emphasis>one of the "heading" containers is present, though <emphasis role="bold"><emphasis role="strikethrough">each</emphasis><emphasis role="underline">any one of them</emphasis></emphasis> may be <emphasis role="bold"><emphasis role="underline">present but </emphasis></emphasis>empty.</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>
      
    </chapter>
</book>