<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1560</title>
    <subtitle>Add missing language of content item and descendants to RDSR</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>March 2016 Voting Packet</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2016/01/22</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                  xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>2015/11/11</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1560</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add missing language of content item and descendants to RDSR</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para>
                   <para>The conventional language content item that is always present as a modifier of the document title in root templates was omitted from RDSR. Add it</para>
                 </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title></title>

        <section>
            <title></title>
            <informaltable rules="all" frame="box">
                <tr><td><para><emphasis role="italic">Amend DICOM PS3.16 as follows:</emphasis></para></td></tr>
            </informaltable>
        </section>
        
        <section label="TID 10001" status="3" xml:id="sect_TID_10001">
            <title>Projection X-Ray Radiation Dose</title>
            <table frame="box" label="TID 10001" rules="all" xml:id="table_TID_10001">
               <caption>Projection X-Ray Radiation Dose</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0e24f4bf-aaac-405b-804a-133a5f7afa2d"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e5e36fce-9125-44dd-afa1-50c4cf4cb28a">
                           <emphasis role="bold">NL</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ff60cf12-3866-4d5b-9647-fc683d80695d">
                           <emphasis role="bold">Rel with Parent</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0089a6f5-d873-45bd-a58b-69bba6a64d82">
                           <emphasis role="bold">VT</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_44f69784-cf8c-48be-aaa0-ba625d7e35c5">
                           <emphasis role="bold">Concept Name</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_85b35247-ff0b-44c2-804c-4b0c3addfb9f">
                           <emphasis role="bold">VM</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_eec626e2-2b34-4ced-ace5-342e955028e8">
                           <emphasis role="bold">Req Type</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_32c626a0-840e-4e91-bcbc-5cf758e08fd1">
                           <emphasis role="bold">Condition</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_67bc0671-9052-4dcc-b737-547e1c6125ca">
                           <emphasis role="bold">Value Set Constraint</emphasis>
                        </para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_db233da6-2c4f-4b2b-90bb-ec35d8cb97e0">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c7a2b129-bbaa-49e5-adc6-a38b84f0cc83"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fcea0546-0f35-4a60-b9b1-4fe312b5c336"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_526bbf5c-4b1d-49f2-a670-738b579cd306">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_333469e0-3570-4a25-b3c6-13db59afa9f2">EV <link linkend="DCM_113701" xrefstyle="select: nopage">(113701, DCM, "X-Ray Radiation Dose Report")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e1131021-cfc0-4768-a265-f4936d22e261">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ff943c7a-709e-4f07-89f8-06b9af1cf2ad">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9f513ba6-27fe-4c1c-8e14-d3f574ee732b"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_964ad18a-69a5-4aff-824c-cdfe2574207f">Root node</para>
                     </td>
                  </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">1b</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">HAS CONCEPT MOD</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">INCLUDE</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                    </emphasis></emphasis></para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                       </td>
                   </tr>
                   <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bae755ba-efd7-4fad-ba0b-8549a8e46ade">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b17b97c8-a2d6-42f0-855a-2793ce507d03">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_024902a0-3d29-4013-8954-d42d04b3e872">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_98bd1b49-110f-4880-a5d6-478898f1b7c0">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_340a8d42-6b36-4092-96a3-917270dc79b3">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d549af16-6e6f-4d02-9d64-3762692a5a74">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d8d9f0b2-5b05-49e9-8693-f98d8787af08">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_893aee06-341b-4661-90ef-a7bb2dd6deca"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_28adfd60-3cd0-4116-a473-52ae5e656497">DT <link linkend="DCM_113704" xrefstyle="select: nopage">(113704, DCM, "Projection X-Ray")</link>
                        </para>
                        <para xml:id="para_7ff21ea0-9652-4849-aa1e-59616ff1cb4c">DT (P5-40010, SRT, "Mammography")</para>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>

<section label="TID 10011" status="3" xml:id="sect_TID_10011">
            <title>CT Radiation Dose</title>
            <table frame="box" label="TID 10011" rules="all" xml:id="table_TID_10011">
               <caption>CT Radiation Dose</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_51762a41-dd85-4c1d-b4d9-c0824c384402"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_94793ca9-091a-49b5-96f1-9a90548525b9">
                           <emphasis role="bold">NL</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b38b5e62-b4e0-444b-a435-84b79aa5bc46">
                           <emphasis role="bold">Rel with Parent</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f6e8831c-201e-4ce9-8ae1-b1c5e43e70fe">
                           <emphasis role="bold">VT</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b42aee19-3c17-446d-84ca-752ab925e136">
                           <emphasis role="bold">Concept Name</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8ac6a678-694d-4c49-bb9d-afcaae317ac6">
                           <emphasis role="bold">VM</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fecfd975-f40e-44d6-b8cf-4f3eac41543c">
                           <emphasis role="bold">Req Type</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8007047c-7318-4db1-8c22-6275a5f4d965">
                           <emphasis role="bold">Condition</emphasis>
                        </para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6f6f1c1b-c4b7-44f9-a97d-a56eaaaaf83c">
                           <emphasis role="bold">Value Set Constraint</emphasis>
                        </para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dd46632c-3096-4f4b-bf05-fa7d7dc05c00">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1e65a4e2-8517-4213-8321-c778ebc544f6"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_572fc4b5-bfc8-4a22-92c3-86a48f5040b2"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0aeab9b4-1835-409b-9cf7-c3fb87798bdd">CONTAINER</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3e3d5fff-2dfd-4e1d-acdd-dd952e4739f4">EV <link linkend="DCM_113701" xrefstyle="select: nopage">(113701, DCM, "X-Ray Radiation Dose Report")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_30582600-ac2c-4c79-88fc-597bab0cc409">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_40d9b9b9-1fd4-4989-a0bf-f741d0efbe87">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_77ee0220-741b-47fa-9bbe-2c88769a1d65"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_64f5758f-060a-44f7-9390-ef322ff4898e">Root node</para>
                     </td>
                  </tr>
                   <tr valign="top">
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">1b</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">HAS CONCEPT MOD</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">INCLUDE</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                           </emphasis></emphasis></para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                       </td>
                       <td align="center" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                       </td>
                       <td align="left" colspan="1" rowspan="1">
                           <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                       </td>
                   </tr>
                   <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5ad35723-c12a-4f25-8d59-7011ddd2beca">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_91efce11-9d19-40ba-88b1-10c32b1ecebf">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a7be3838-705b-4e82-ab02-1f0bdd7c825c">HAS CONCEPT MOD</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_68da0659-e623-4022-9860-237501e4f8f5">CODE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_42d58155-c136-4390-b8a4-2d7e9ecac1e9">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a7d81258-face-4fb4-9845-5e392faf9157">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_566c081c-a0d4-451b-9c63-be03bda675a7">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_808e7405-5e60-43f8-9a69-e88db2a1708c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bb5073b7-749b-43e9-b7bd-2ee9f74bde96">EV (P5-08000, SRT, "Computed Tomography X-Ray")</para>
                     </td>
                  </tr>
               </tbody>
            </table>
         </section>
        <section label="TID 10021" status="3" xml:id="sect_TID_10021">
            <title>Radiopharmaceutical Radiation Dose</title>
            <table frame="box" label="TID 10021" rules="all" xml:id="table_TID_10021">
                <caption>Radiopharmaceutical Radiation Dose</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62e45db9-0c26-4832-8379-e8b7f3250a64"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fec1d7d7-8c73-41f1-bc8f-45587ac330bf">
                                <emphasis role="bold">NL</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e43de2bc-1cd9-422b-91a5-f36b1ddae1c0">
                                <emphasis role="bold">Rel with Parent</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_71b064a8-6708-4af3-902f-ee2952d9f24a">
                                <emphasis role="bold">VT</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_379178fd-8e1f-4e87-b77f-953dfafee47b">
                                <emphasis role="bold">Concept Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0f4ce30-79a4-4760-a8ff-0243649c7500">
                                <emphasis role="bold">VM</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df74214a-d185-449d-b9a1-8f626ca682e2">
                                <emphasis role="bold">Req Type</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_00f4fab1-58f4-48a2-8a4b-169e537ad377">
                                <emphasis role="bold">Condition</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d901941-f98e-4498-9992-98584828594a">
                                <emphasis role="bold">Value Set Constraint</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7a81e1c1-107e-4b15-a75a-1fb2eefdff67">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1"/>
                        <td align="left" colspan="1" rowspan="1"/>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5b5c83fe-1cf2-481a-a1dd-61a569babc4f">CONTAINER</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aa90d5f7-3988-4a5e-a773-c3ca5c812722">EV <link linkend="DCM_113500" xrefstyle="select: nopage">(113500, DCM, "Radiopharmaceutical Radiation Dose Report")</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5aa52d36-761e-4189-8698-281288b1f7be">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ed6d652e-6d62-4996-af1a-65188c927c09">M</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1"/>
                        <td align="left" colspan="1" rowspan="1"><para>Root node</para></td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1b</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">HAS CONCEPT MOD</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">INCLUDE</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"></emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6de1eedb-f181-4d53-b8e6-b4f8e4f2072d">2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_393bf075-570a-4f6c-ae3f-d536ec3f3710">&gt;</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fb43e8ec-863d-4706-a315-200fff08929f">HAS CONCEPT MOD</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5d15d29a-52de-4288-99ff-72d269eeae0f">CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6a803a83-5c08-4879-b9b4-1fe4d66e568c">EV (G-C2D0, SRT, "Associated Procedure")</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_609c1b50-dcce-4ffe-af5b-48f4c3f10665">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fa7beb0c-d19e-4707-9a2b-0bf1cac3422f">M</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1"/>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4972d5d5-a533-456b-9c48-c9972597d862">D<xref linkend="sect_CID_3108" xrefstyle="select: labelnumber quotedtitle"/>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section>
            <title></title>
            <informaltable rules="all" frame="box">
                <tr><td><para><emphasis role="italic">For reference DICOM PS3.16 unchanged:</emphasis></para></td></tr>
            </informaltable>
        </section>

        <section label="TID 1204" status="3" xml:id="sect_TID_1204">
            <title>Language of Content Item and Descendants</title>
            <para xml:id="para_5383742b-cc4c-4a4d-a0cb-f8483c7cc90a">Defines a mechanism for specifying the language in which the value and the Concept Name of the parent Content Item and any other descendants of the parent Content Item is written.</para>
            <note>
                <para xml:id="para_0c53c217-16a1-4df5-962e-57b25ee58a2e">The language codes specified in <xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/> optionally allow the encoding of the country of language in the code value for the language. Encoding of the country of language in a separate subsidiary Concept Modifier Content Item is allowed for backward compatibility with previous editions of the Standard.</para>
            </note>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_81c26780-c5f2-4514-a6bb-5509aaf39141">
                            <emphasis role="bold">Non-Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Order:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1e8d4541-1a3a-49d2-9dd6-70e3381901ab">
                            <emphasis role="bold">Significant</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Root:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d34d3bb6-f7fa-45cc-a99b-dd15014a75b0">
                            <emphasis role="bold">No</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="TID 1204" rules="all" xml:id="table_TID_1204">
                <caption>Language of Content Item and Descendants</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_611638ce-c881-4d3c-b080-e7c11706d507"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_416de455-0cf3-4c46-a109-46d017b07619">NL</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ca50250b-b3e6-4d04-bae0-60bbaf4619df">Rel with Parent</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0af7bd8f-e8f4-45c8-8548-96bbd461efd6">VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37c9a2c8-6a16-47bc-9342-405c5a60ae37">Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ce4c434f-a525-4929-9226-7b37049b9e49">VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09129577-d354-45aa-b0f4-0c978591ff55">Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b0b508ee-07fc-42b8-8f89-4860f82edd84">Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14751ee9-c0bf-4ac5-97b0-cf80fe84d737">Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_df443627-95ea-4adc-ae63-e7ad179eb520">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_04a04443-ad2f-4cf6-b626-9f552ced2768"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e59c3d64-2b8d-412c-84d0-ee1a9c3812a6">HAS CONCEPT MOD</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_16edeb1c-d94a-41e7-99dd-57c0859af568">CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6f64e0f4-43be-40c4-bf44-a3f8a0566bbe">EV <link linkend="DCM_121049" xrefstyle="select: nopage">(121049, DCM, "Language of Content Item and Descendants")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b475906b-ecfd-4437-a2b3-36a260dd7796">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_73b3fc43-d4a7-4980-a0fc-2993dfc4edd5">M</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b6305d57-746a-4775-a622-bed632d02847"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fd8245bd-d484-4c7b-8d83-82186d72d296">D<xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_12874d11-631c-48a2-ae3d-8882861b3f2b">2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_50704518-b1b1-42dd-b9fc-f4387b0087ba">&gt;</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9dcb18fa-2798-46c4-8325-46b038e9c0ed">HAS CONCEPT MOD</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6002168f-70e9-49df-953a-9d4e9f982740">CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f0a3d411-7510-47cb-b925-5578a351dea8">EV <link linkend="DCM_121046" xrefstyle="select: nopage">(121046, DCM, "Country of Language")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_35b3c2cb-fadb-4ef7-b5af-1509ab2b1867">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3ae5efc-6f60-4358-a8f9-a67e28d97432">U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_84981529-02d0-4c7b-a8eb-df883c741523"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3c07ccbd-a694-4e6e-9d8f-359eb6afae42">D<xref linkend="sect_CID_5001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 5000" status="3" xml:id="sect_CID_5000">
            <title>Languages</title>
            <para xml:id="para_e7bb0c71-c1c9-4159-892c-e79c455e8b25">Context Group ID 5000 comprises the language tag coding scheme of RFC 4646. The Coding Scheme Designator (0008,0102) shall be IETF4646.</para>
            <note>
                <orderedlist numeration="arabic">
                    <listitem>
                        <para xml:id="para_fb3097f1-a953-4ba5-8b16-1cdbb0edc3f1">The RFC 4646 coding scheme is constructed from a primary subtag component encoded using the language codes of ISO 639, plus codes for extensions for languages not represented in ISO 639. The code optionally includes additional subtag components, for scripts encoded using the four letter codes of ISO 15924, and for regions encoded using the two letter country codes of ISO 3166.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_df31067b-288e-40dd-a4c6-d2421e7c6dcb">RFC 4646 may be obtained at 
                            <link xl:href="http://www.ietf.org/rfc/rfc4646.txt"/>. RFC 4646 obsoletes RFC 3066 and RFC 1766, but is forward compatible with those specifications.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_d1038cb4-c56f-426d-8437-a214dc903c89">ISO 639 codes may be obtained at 
                            <link xl:href="http://www.loc.gov/standards/iso639-2/langhome.html"/>.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_884503aa-a343-4a75-a3ca-a4adc12a5bc6">The two letter country codes of ISO 3166 may be obtained at 
                            <link xl:href="https://www.iso.org/obp/ui/#search/code/"/>
                        </para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_e4f6709a-5245-48b5-a456-af33f8a58082">IANA language tag registrations may be obtained at 
                            <link xl:href="http://www.iana.org/assignments/language-subtag-registry/language-subtag-registry"/>
                        </para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_59a9f559-add5-41a6-8dcb-f180d7b54466">In previous editions of the Standard, this Context Group formerly included the three letter language codes of ISO 639-2/B, using Coding Scheme Designator ISO639_2, or the language codes of RFC 3066, using Coding Scheme Designator RFC3066, and several IANA-registered language code extensions, using Coding Scheme Designator IANARFC1766.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_6688faee-f6e0-408e-84fa-fe84db5649c2">In previous editions of the Standard, this Context Group provided only language identifiers, with national or regional variant identified in a separate attribute or Content Item.</para>
                    </listitem>
                </orderedlist>
            </note>
        </section>
        
        <section label="CID 5001" status="3" xml:id="sect_CID_5001">
            <title>Countries</title>
            <para xml:id="para_cc316a36-0c16-4556-83f3-8f7e9a2aae8d">Context Group ID 5001 comprises the two letter country code scheme of ISO 3166. The Coding Scheme Designator (0008,0102) shall be ISO3166_1.</para>
            <note>
                <para xml:id="para_440a9360-ccf6-4258-92e3-055a0b6c8f2f">The two letter country codes of ISO 3166 may be obtained at 
                    <link xl:href="http://www.iso.ch/iso/en/prods-services/iso3166ma/02iso-3166-code-lists/index.html"/>
                </para>
            </note>
        </section>
    </chapter>
</book>