<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1547</title>
    <subtitle>Add syringe to device CID</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2015/11/11</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
               <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                  xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2015/09/28</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1547</para></td>
            </tr>
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add syringe to device CID</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para>
                   <para>Syringes filled with some substance are often used as phantoms.</para>
               <para>CID 4051 is the baseline CID for the Device Sequence in the Device Module, which is described in the Quality Control Image attribute as being a means of describing the phantom.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title></title>
        <section>
            <title></title>
            <informaltable rules="all" frame="box">
                <tr><td><para><emphasis role="italic">Amend DICOM PS3.16 as follows:</emphasis></para></td></tr>
            </informaltable>
        </section>
        
       <section label="CID 4051" status="3" xml:id="sect_CID_4051">
          <title>General Devices</title>
          <variablelist spacing="compact">
             <varlistentry>
                <term>
                   <emphasis role="bold">Type:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_61ce3149-9538-4471-b8fc-11ce0d3787a9">
                      <emphasis role="bold">Extensible</emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">Version:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_5cf212ed-6658-4c2d-9fc8-490df8f8fd39">
                     <emphasis role="bold"><emphasis role="strikethrough">20061023</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                  </para>
                </listitem>
             </varlistentry>
          </variablelist>
          <table frame="box" label="CID 4051" rules="all" xml:id="table_CID_4051">
             <caption>General Devices</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_50c526d6-cdd1-4d81-8a56-52e2dc138e22">
                         <emphasis role="bold">Coding Scheme Designator</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_9525d8a2-af2f-4f6e-845c-0f13571c2417">
                         <emphasis role="bold">Code Value</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_70db9f68-7915-41ae-ae9d-ff1109cbd9fc">
                         <emphasis role="bold">Code Meaning</emphasis>
                      </para>
                   </th>
                </tr>
             </thead>
             <tbody>
                <tr valign="top">
                   <td align="left" colspan="3" rowspan="1">
                      <para xml:id="para_127cfb36-b1c4-4544-908b-bf006c49e996">
                         <emphasis role="italic">Include CID 8 Angiographic Interventional Devices<!--<xref linkend="sect_CID_8" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                         </emphasis>
                      </para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="3" rowspan="1">
                      <para xml:id="para_084b75dc-628b-4469-81c4-1461ca05f794">
                         <emphasis role="italic">Include CID 3451 Calibration Objects<!--<xref linkend="sect_CID_3451" xrefstyle="select: labelnumber quotedtitle nopage"/>-->
                         </emphasis>
                      </para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="left" colspan="3" rowspan="1">
                      <para xml:id="para_6a607420-0dd4-4697-b80c-a0f4fc305ce4">
                         <emphasis role="italic">Include <xref linkend="sect_CID_4052" xrefstyle="select: labelnumber quotedtitle nopage"/>
                         </emphasis>
                      </para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">SRT</emphasis></emphasis></para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">A-10150</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Syringe</emphasis></emphasis></para>
                   </td>
                </tr>
             </tbody>
          </table>
       </section>
       <section label="CID 4052" status="3" xml:id="sect_CID_4052">
          <title>Phantom Devices</title>
          <variablelist spacing="compact">
             <varlistentry>
                <term>
                   <emphasis role="bold">Type:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_662815ce-7739-4a06-bacc-bc401b3bb9cf">
                      <emphasis role="bold">Extensible</emphasis>
                   </para>
                </listitem>
             </varlistentry>
             <varlistentry>
                <term>
                   <emphasis role="bold">Version:</emphasis>
                </term>
                <listitem>
                   <para xml:id="para_5ee15795-850b-4616-81a9-ee5b6296a61b">
                      <emphasis role="bold">20061023</emphasis>
                   </para>
                </listitem>
             </varlistentry>
          </variablelist>
          <table frame="box" label="CID 4052" rules="all" xml:id="table_CID_4052">
             <caption>Phantom Devices</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_a3751148-d5f3-4371-9654-28e4c403f851">
                         <emphasis role="bold">Coding Scheme Designator</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_da18a214-fc3a-4a2f-be15-17876e070c22">
                         <emphasis role="bold">Code Value</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para xml:id="para_a4f46920-5b59-4ec6-85b4-fc8d04568fa5">
                         <emphasis role="bold">Code Meaning</emphasis>
                      </para>
                   </th>
                </tr>
             </thead>
             <tbody>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_82be7c1e-be11-4762-bbaf-b7d1053a43a6">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_1c5a5888-7100-4c1a-9570-61a15baa32a6">
                         <link linkend="DCM_113681" xrefstyle="select: nopage">113681</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_4e69a7c5-8019-46cd-a7a8-c7622729567e">Phantom</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_267baac7-bdcd-496c-b875-9ba689fa29ac">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_531ccfad-f58f-4c9c-bf8d-0ac361cde30f">
                         <link linkend="DCM_113682" xrefstyle="select: nopage">113682</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_4aefedfa-817c-49ef-8341-7cc381bd3454">ACR Accreditation Phantom - CT</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_73c38d93-fe33-49c0-ad46-aa218293241d">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_b9f1ed2f-0cbe-47bf-b170-39d1090d1fad">
                         <link linkend="DCM_113683" xrefstyle="select: nopage">113683</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_1a066b0a-e71f-4bab-803c-1d136c4d260e">ACR Accreditation Phantom - MR</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_5d7d81ae-0556-46d6-9893-6be060a7617d">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_8d987d4b-1181-4b23-a63b-8355d5d86cee">
                         <link linkend="DCM_113684" xrefstyle="select: nopage">113684</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_c711b409-cadc-442c-9c16-72bcdedc530c">ACR Accreditation Phantom - Mammography</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_4224b4dc-53b8-4114-8709-0e76e588be69">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_f74387e9-a571-4d41-8210-ee0b1c77313d">
                         <link linkend="DCM_113685" xrefstyle="select: nopage">113685</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_e07269b5-c04b-4071-bc84-a0e171ff8715">ACR Accreditation Phantom - Stereotactic Breast Biopsy</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_dc5b2436-1a77-44da-a0a5-1e37a1c7f661">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_6b869f40-7c95-41c6-862d-5a8bfe175109">
                         <link linkend="DCM_113686" xrefstyle="select: nopage">113686</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_8418aa7e-0154-4dad-9b16-3b586e5016b9">ACR Accreditation Phantom - ECT</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_d754bdd6-fef4-4c32-8bd7-e7f9f6b9ae56">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_d5381155-ef3f-4f65-9727-af5b048abe22">
                         <link linkend="DCM_113687" xrefstyle="select: nopage">113687</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_3b507a77-b999-4c56-a69b-67767df3f7f2">ACR Accreditation Phantom - PET</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_5473a3bb-ae7f-4f86-8c74-8f0fdfd94909">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_6b8f4cfd-b8d5-46a5-be81-a40221532acd">
                         <link linkend="DCM_113688" xrefstyle="select: nopage">113688</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_9ed93143-58b4-49e8-a213-cce7bda65b0f">ACR Accreditation Phantom - ECT/PET</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_0a0155a1-0dc4-49d6-9724-2bae3b94778b">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_b6b9cb7b-6b58-45b2-8999-c2b4cd03c557">
                         <link linkend="DCM_113689" xrefstyle="select: nopage">113689</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_490c3ed4-d95e-4bc5-a239-92069902a954">ACR Accreditation Phantom - PET Faceplate</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_dd276c0d-e183-4740-a883-87b41560ad40">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_9bbc1b45-72bd-42eb-90d8-b86d6251e06d">
                         <link linkend="DCM_113690" xrefstyle="select: nopage">113690</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_2efb07b5-0314-4936-8d3e-7b33c23202a0">IEC Head Dosimetry Phantom</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_bcb8f67c-c8bb-4cc7-a446-f2e2f255baa1">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_d559c959-73f4-46e0-83f6-539bbcac48f0">
                         <link linkend="DCM_113691" xrefstyle="select: nopage">113691</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_e0d7cf91-68a8-439f-a35b-92a3c3fe598c">IEC Body Dosimetry Phantom</para>
                   </td>
                </tr>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_b1ce7c88-7361-412b-ae68-c0c0f6ec2993">DCM</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_f83e1b62-a546-407c-aa43-b2620ccd49ef">
                         <link linkend="DCM_113692" xrefstyle="select: nopage">113692</link>
                      </para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_efd9789f-0eed-4e9c-a5ef-8bb0d0dc39da">NEMA XR21-2000 Phantom</para>
                   </td>
                </tr>
             </tbody>
          </table>
       </section>
       
       
    </chapter>
</book>