<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-1521</title>
  <subtitle>Add Root Template Definition</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>January 2016 Voting Packet</para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>2015/11/11</para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
          xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>Jörg Riesmeier</para><para><link
          xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dicom@jriesmeier.com"/></para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>2015/05/21</para></td>
      </tr>
    </informaltable>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1521</para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Root Template Definition</para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Name of Standard</para>
          <para>PS3.16</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Rationale for Correction:</para>
          <para>The term "root template" is used extensively in PS3.16, but without a formal definition.</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
      </tr>
    </informaltable>
  </chapter>
  <chapter>
    <title></title>
    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Amend DICOM PS 3.16 as follows:</emphasis></para></td></tr>
      </informaltable>
    </section>
    
    <section label="3" status="1" xml:id="chapter_3">
      <title>Definitions</title>
      <para xml:id="para_f1b16969-20b4-46c4-8a57-a2f8d6e5e387">For the purposes of this Standard the following definitions apply.</para>
      <glossary>
        <title/>
        <glossdiv label="3.1" status="2" xml:id="sect_3.1">
          <title>Codes and Controlled Terminology Definitions:</title>
          <para xml:id="para_0486a070-c8c5-459d-8748-50ba181f01e0">The following definitions are commonly used in this Part of the DICOM Standard:</para>
          <glossentry>
            <glossterm>Baseline Context Group Identifier (BCID)</glossterm>
            <glossdef>
              <para xml:id="para_c7c77b22-ec7f-443f-a7c3-3b292bd0328a">Identifier that specifies the suggested Context Group for a Code Sequence Attribute.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Defined Context Group Identifier (DCID)</glossterm>
            <glossdef>
              <para xml:id="para_cdfbdf21-8df7-4c7f-9bdd-67cfa278d18e">Identifier that specifies the Context Group for a Code Sequence Attribute that shall be used.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Extensible Context Group</glossterm>
            <glossdef>
              <para xml:id="para_d53236fc-950c-42e7-9f59-fe21c709efd6">Context Group that may be extended by a particular application by inclusion of additional concepts.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Non-Extensible Context Group</glossterm>
            <glossdef>
              <para xml:id="para_66de5d23-c4f1-4e4e-8679-f3c94cc27797">Context Group whose defined set of concepts shall not be extended by an application.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Context Group</glossterm>
            <glossdef>
              <para xml:id="para_1f2dfd0b-b432-4fe6-a326-7c2a331bc79b">A set of coded concepts defined by a Mapping Resource forming a set appropriate to use in a particular context.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Context Group Version</glossterm>
            <glossdef>
              <para xml:id="para_d1ebf453-eb1b-4692-8005-7ebc96ece195">Version of a Context Group.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Context ID (CID)</glossterm>
            <glossdef>
              <para xml:id="para_1885a739-eae9-413a-b4e8-9620a386b19b">Identifier of a Context Group.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Mapping Resource</glossterm>
            <glossdef>
              <para xml:id="para_1188d4b9-9f27-4102-b5b4-12ebe0a24628">A resource that defines context-dependent usage constraints (i.e., Value Set or
                Relationship Type restrictions) for Attributes. A resource that specifies the mapping
                of the content of an external controlled terminology to the components of a message
                standard.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Relationship Type</glossterm>
            <glossdef>
              <para xml:id="para_307f585f-6dcc-4a6f-a19d-01f8d56e2bb3">The association between two Concepts. Examples: "HAS PROPERTIES", "CONTAINS", "INFERRED FROM".</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>DICOM Content Mapping Resource (DCMR)</glossterm>
            <glossdef>
              <para xml:id="para_2b5051f1-6dae-4d3e-a79c-08298fe57af6">A Mapping Resource that defines Templates and Context Groups for use in DICOM IODs.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Template</glossterm>
            <glossdef>
              <para xml:id="para_4fbbe304-f9f5-493b-861d-3f61416b643e">A pattern that describes the Content Items, Value Types, Relationship Types and Value Sets that may be used in part of a Structured Report content tree, or in other Content Item constructs, such as Acquisition Context or Protocol Context. Analogous to a Module of an Information Object Definition.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Template ID (TID)</glossterm>
            <glossdef>
              <para xml:id="para_0e693a15-fcab-4509-bb38-042b0d6c7dcd">Identifier of a Template.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Value Set</glossterm>
            <glossdef>
              <para xml:id="para_c1a9bb3c-5876-4e47-9707-78119fcdcf1e">The allowed values of a Code Sequence Attribute in a given context. Specified either as one or more individual values or by reference to a Context Group.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Baseline Template Identifier (BTID)</glossterm>
            <glossdef>
              <para xml:id="para_4d341e60-6b5e-49af-a5f4-6db76947d5e8">Identifier that specifies a Template suggested to be used in the creation of a set of Content Items.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Defined Template Identifier (DTID)</glossterm>
            <glossdef>
              <para xml:id="para_6970224b-de48-422c-bf7b-93f55b6de69a">Identifier that specifies a Template that shall be used in the creation of a set of Content Items.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Extensible Template</glossterm>
            <glossdef>
              <para xml:id="para_c7a846f5-c432-4585-96bb-3b41576d2fd2">A Template that may be extended by a particular application by inclusion of additional Content Items beyond those specified in the Template.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Non-Extensible Template</glossterm>
            <glossdef>
              <para xml:id="para_2cafb152-6a8b-40c8-8c22-facf27740179">A Template that specifies the exact set of Content Items and corresponding Value Sets that shall be used and that shall not be extended by an application.</para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm><emphasis role="bold"><emphasis role="underline">Root Template</emphasis></emphasis></glossterm>
            <glossdef>
              <para><emphasis role="bold"><emphasis role="underline">A Template whose first content item is a CONTAINER content item encoded in the top level Data Set of a SOP Instance. I.e., the "root node" of the "content tree".</emphasis></emphasis></para>
            </glossdef>
          </glossentry>
          <glossentry>
            <glossterm>Coding schemes</glossterm>
            <glossdef>
              <para xml:id="para_0576e070-1b8f-458c-a994-299303d1b1c7">Dictionaries (lexicons) of concepts (terms) with assigned codes and well defined meanings. 
                <note>
                  <para xml:id="para_afb7f486-6cba-4706-ba84-b7ac8f4af2e2">Examples of coding schemes include SNOMED and LOINC.</para>
                </note>
              </para>
            </glossdef>
          </glossentry>
        </glossdiv>
        <glossdiv label="3.2" status="2" xml:id="sect_3.2">
          <title>Information Object Definitions:</title>
          <para xml:id="para_295dc731-c6ae-4b90-983e-69f415c94847">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>:</para>
          <glossentry>
            <glossterm>Code Sequence Attribute</glossterm>
            <glossdef>
              <para xml:id="para_e2b93a62-bc0b-4f0d-8584-a742c0207a53">See <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>.</para>
            </glossdef>
          </glossentry>
        </glossdiv>
      </glossary>
    </section>
    
  </chapter>
</book>