  <title>CP-1428</title>
  <subtitle>Use Pixel Measures in Enhanced US Volume</subtitle>
  <chapter>
    <title/>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>STATUS</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>Assigned</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Date of Last Update</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>2014/09/09</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Person Assigned</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>David Clunie</para>
          <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
              xlink:href="mailto:dclunie@dclunie.com"/></para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Submitter Name</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>David Clunie</para>
          <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
              xlink:href="mailto:dclunie@dclunie.com"/></para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Submission Date</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>2014/09/02</para>
        </td>
      </tr>
    </informaltable>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Correction Number CP-1428</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Log Summary: Use Pixel Measures in Enhanced US Volume</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Name of Standard</para>
          <para>PS3.3 2014b</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
          <para>The Enhanced US Volume IOD failed to use the Pixel Measures functional group that is
            used by all other enhanced family IODs to describe the Pixel Spacing. There is no reason
            for this gratuitous inconsistency.</para>
          <para>Add it as a required functional group.</para>
          <para>Currently Pixel Spacing is Type 1 in the Enhanced US Image Module. Remove it.</para>
          <para>Since the Enhanced US Volume IOD has not yet been widely adopted, it is reasonable to
            make these changes to mandatory attributes at this time.</para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
      </tr>
    </informaltable>
  </chapter>
  <chapter>
    <title/>
    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.3 as follows:</emphasis></para>
          </td>
        </tr>
      </informaltable>
    </section>
    
    <section label="A.59.4" status="3" xml:id="sect_A.59.4">
      <title>Enhanced US Volume Functional Group Macros</title>
      <para><xref linkend="table_A.59-2" xrefstyle="select: label"/> specifies the use of the Functional Group Macros used in the Multi-frame Functional Groups Module for the Enhanced US Volume IOD.</para>
      <table frame="box" label="A.59-2" rules="all" xml:id="table_A.59-2">
        <caption>Enhanced US Volume Functional Group Macros</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>Functional Group Macro</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>Section</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>Usage</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>Frame Content</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_C.7.6.16.2.2" xrefstyle="select: labelnumber"/>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>M - May not be used as a Shared Functional Group.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Pixel Measures</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold"><emphasis role="underline"><xref linkend="sect_C.7.6.16.2.1" xrefstyle="select: labelnumber"/></emphasis></emphasis>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">M</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>Plane Position (Patient)</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_C.7.6.16.2.3" xrefstyle="select: labelnumber"/>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>U</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>Plane Orientation (Patient)</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_C.7.6.16.2.4" xrefstyle="select: labelnumber"/>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>U</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>Plane Position (Volume)</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_C.7.6.16.2.21" xrefstyle="select: labelnumber"/>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>M - May not be used as a Shared Functional Group. See <xref linkend="sect_A.59.4.1.2" xrefstyle="select: label"/>.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>Plane Orientation (Volume)</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>
                <xref linkend="sect_C.7.6.16.2.22" xrefstyle="select: labelnumber"/>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>M - May not be used as a Per-Frame Functional Group. See <xref linkend="sect_A.59.4.1.2" xrefstyle="select: label"/>.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
            <section label="C.8.24.3" status="4" xml:id="sect_C.8.24.3">
          <title>Enhanced US Image Module</title>
          <para>...</para>
          <table frame="box" label="C.8.24.3-1" rules="all" xml:id="table_C.8.24.3-1">
            <caption>Enhanced US Image Module Attributes</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para>Attribute Name</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para>Tag</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para>Type</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para>Attribute Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="strikethrough">Pixel Spacing</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="strikethrough">(0028,0030)</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para><emphasis role="bold"><emphasis role="strikethrough">Physical distance in the patient between the centers of adjacent pixels, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing, in mm.</emphasis></emphasis></para>
                  <para><emphasis role="bold"><emphasis role="strikethrough">See <xref linkend="sect_10.7.1.3" xrefstyle="select: label"/> for further explanation of the value order.</emphasis></emphasis></para>
                </td>
              </tr>
              </tbody>
            </table>
          </section>


    