<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-1408</title>
  <subtitle>Add NeuroNames as Coding Scheme</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>STATUS</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/06/27</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/06/03</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1408</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add NeuroNames as Coding Scheme</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
        <para>PS3.16 2013</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Rationale for Correction:</para>
        <para>The NeuroNames ontology is widely used in neuroanatomy and contains concepts relevant to
            imaging that are not encoded in other schemes.</para>
          <para>Add a standard value for use as the Coding Scheme Designator and use the existing
            HL7 OID.</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>
    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Amend DICOM PS3.16 Table 8-1 as follows:</emphasis></para></td></tr>
      </informaltable>

      <table rules="all" frame="box" label="8-1" xml:id="table_8-1">
        <caption>Coding Schemes</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>Coding Scheme Designator</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>Coding Scheme UID</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>Description</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>2.16.840.1.113883.6.210</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>NeuroNames. The numeric brainInfoID is used as the code value. See <link
                  xl:href="http://braininfo.rprc.washington.edu/aboutBrainInfo.aspx#NeuroNames"
                /></para>
            </td>
          </tr>
        </tbody>
      </table>
      
      
    </section>
  </chapter>
</book>