  <title>CP-1407</title>
  <subtitle>Add diffusion tractography related sites</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>STATUS</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Nov 2014 Voting Packet</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/10/22</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>James Reuss</para>
        <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
          xlink:href="mailto:jreuss@prismclinical.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/05/06</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1407</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add diffusion tractography related sites</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
        <para>PS 3.16 2014c</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
          <para>Rationale for Correction:</para>
          <para>White matter tracts and related structures (as represented with MR diffusion tensor
            tractography) need to be described with a higher degree of anatomical precision as well
            as a different concepts (tracts that span regions) than is currently defined for other
            applications such as segmentation. In addition, the technique is used in various other
            parts of the body (such as in skeletal and cardiac muscle), and tested using phantoms.
            The terminology is applicable to both humans and non-human primates, and in future may
            need to be extended for other research species.</para>
        </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>

    
    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Add new Context Groups to DICOM PS 3.16 Annex B Context Groups as
                follows:</emphasis></para></td></tr>
      </informaltable>
    </section>
    
    <section label="CID cp1407_001" status="3" xml:id="sect_CID_cp1407_001">
      <title>Fiber Tracts In Brainstem</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID cp1407_001" xml:id="table_cp1407_001">
        <caption>Fiber Tracts In Brainstem</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A6620</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior cerebellar peduncle</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>11089000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152391</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A6630</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>middle cerebellar peduncle</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>33723005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152392</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A6640</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior cerebellar peduncle</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>67701001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152393</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-D07EA</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>corticospinal tract in brainstem</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>360568007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1283381</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A5271</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>medial lemniscus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>30114003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228420</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A5272</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral lemniscus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>86136007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152375</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A5250</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>medial longitudinal fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>28390009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152373</para>
            </td>
          </tr>
        </tbody>
      </table>
      <note><para>Organized as described in Wakana, Setsu, Hangyi Jiang, Lidia M. Nagae-Poetscher, Peter C. M. van Zijl, and Susumu Mori. "Fiber Tract–based Atlas of Human White Matter Anatomy." Radiology 230, no. 1 (January 1, 2004): 77–87. doi:10.1148/radiol.2301021640.</para></note>
    </section>
    
    <section label="CID cp1407_002" status="3" xml:id="sect_CID_cp1407_002">
      <title>Projection and Thalamic Fibers</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID cp1407_002" xml:id="table_cp1407_002">
        <caption>Projection and Thalamic Fibers</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>1319</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>corticobulbar tract</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1184617</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>1320</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>corticospinal tract</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0936236</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A3700</para>
            </td>
            <td align="left" colspan="1">
              <para>internal capsule</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>85637007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152341</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A3800</para>
            </td>
            <td align="left" colspan="1">
              <para>external capsule</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>10517005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228313</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-D0829</para>
            </td>
            <td align="left" colspan="1">
              <para>auditory (acoustic) radiation (geniculotemporal tract)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>410726006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1455736</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2880</para>
            </td>
            <td align="left" colspan="1">
              <para>optic radiation (geniculo-calcarine tract, geniculostriate pathway)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>70105001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228277</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>1466</para>
            </td>
            <td align="left" colspan="1">
              <para>inferior optic radiation (Meyer's loop)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C3498430</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><link linkend="DCM_d14070" xrefstyle="select: nopage">d14070</link></para>
            </td>
            <td align="left" colspan="1">
              <para>superior optic radiation (Baum's loop)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>1726</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>anterior thalamic radiation</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C2338170</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>2081</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior thalamic radiation</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C3498751</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>2082</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior thalamic radiation</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C2332665</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>2083</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>posterior thalamic radiation</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C2336194</para>
            </td>
          </tr>
        </tbody>
      </table>
      <note>
        <orderedlist>
          <listitem>
            <para>SNOMED has codes for the corticobulbar and corticospinal tracts and thalamic
              radiations in specific regions (e.g., internal capsule), but not generic codes
              independent of their regional location, so they are not used.</para>
          </listitem>
        </orderedlist>
      </note>
    </section>
    
    <section label="CID cp1407_003" status="3" xml:id="sect_CID_cp1407_003">
      <title>Association Fibers</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID cp1407_003" xml:id="table_cp1407_003">
        <caption>Association Fibers</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>2080</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior longitudinal fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para/>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para/>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><link linkend="DCM_d14071" xrefstyle="select: nopage">d14071</link></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior longitudinal fasciculus I</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><link linkend="DCM_d14072" xrefstyle="select: nopage">d14072</link></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior longitudinal fasciculus II</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><link linkend="DCM_d14073" xrefstyle="select: nopage">d14073</link></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior longitudinal fasciculus III</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>2063</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>arcuate fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2850</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior longitudinal fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>55233005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228273</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2860</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior fronto-occipital fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>13958008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228274</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2861</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior fronto-occipital fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>35664009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228275</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2830</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>uncinate fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>26230003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228271</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2870</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>vertical occipital fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>80434005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228276</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2861</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior fronto-occipital fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>35664009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228275</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2860</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior fronto-occipital fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>13958008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228274</para>
            </td>
          </tr>
        </tbody>
      </table>
      <note><para>The SLF is distinguished from the AF (even though SNOMED and UMLS treat them as synonymous),
          per Makris N, et al. "Segmentation of Subcomponents within the Superior Longitudinal
          Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study." Cerebral Cortex 15, no. 6
          (June 1, 2005): 854–69. doi:10.1093/cercor/bhh186. Hence the SNOMED concept for SLF/AF
          (T-A2820, 89202009, C0228270) is not used. NeuroNames does not describe the other
          subcomponents of the SLF than the AF, so DCM codes are assigned.</para></note>
    </section>
    
    <section label="CID cp1407_004" status="3" xml:id="sect_CID_cp1407_004">
      <title>Limbic System Tracts</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID cp1407_004" xml:id="table_cp1407_004">
        <caption>Limbic System Tracts</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2840</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>cingulum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>37035000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228272</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2970</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>fornix</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>87463005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152334</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>286</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>stria terminalis</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0175243</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
    <section label="CID cp1407_005" status="3" xml:id="sect_CID_cp1407_005">
      <title>Commissural Fibers</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID cp1407_005" xml:id="table_cp1407_005">
        <caption>Commissural Fibers</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2980</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>anterior commissure</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>62872008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152335</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2700</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>corpus callosum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>88442005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0010090</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2730</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>genu of corpus callosum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>70215001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152321</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2710</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>splenium of corpus callosum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>23347006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152319</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2781</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>tapetum of corpus callosum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>60105000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1744614</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2760</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>forceps minor</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>42932006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152325</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2750</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>forceps major</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>80049006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0809941</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2790</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>posterior commissure</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>28997003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152327</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A4950</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>habenular commissure</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>6866008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152363</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
    <section label="CID cp1407_006" status="3" xml:id="sect_CID_cp1407_006">
      <title>Cranial Nerves</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID cp1407_006" xml:id="table_cp1407_006">
        <caption>Cranial Nerves</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2920</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>olfactory tract</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>3960005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0162435</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8040</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>optic nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>18234004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0029130</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8070</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>oculomotor nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>56193007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0028864</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8110</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>trochlear nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>39322007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0041159</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8150</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>trigeminal nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>27612005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0040996</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8130</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>abducens nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>80622005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0000741</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8410</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>facial nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>56052001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0015462</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8500</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>vestibulocochlear nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>8598002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0001162</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8570</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>glossopharyngeal nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>21161002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0017679</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8640</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>vagus nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>88882009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0042276</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8780</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>accessory nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>15119000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0000905</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8820</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>hypoglossal nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>37899009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0020614</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
    <section label="CID cp1407_007" status="3" xml:id="sect_CID_cp1407_007">
      <title>Spinal Cord Fibers</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID cp1407_007" xml:id="table_cp1407_007">
        <caption>Spinal Cord Fibers</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A7081</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>dorsal funiculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>59752008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228576</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A7061</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>ventral funiculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>31701002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228570</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A7091</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral funiculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>14892003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228583</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
    <section label="CID cp1407_SSS" status="3" xml:id="sect_CID_cp1407_SSS">
      <title>Tractography Anatomic Sites</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      
      <table rules="all" frame="box" label="CID cp1407_SSS" xml:id="table_cp1407_SSS">
        <caption>Tractography Anatomic Sites</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="5" rowspan="1">
              <para>
                <emphasis role="italic">Include <xref linkend="sect_CID_cp1407_001" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis>
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="5" rowspan="1">
              <para>
                <emphasis role="italic">Include <xref linkend="sect_CID_cp1407_002" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis>
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="5" rowspan="1">
              <para>
                <emphasis role="italic">Include <xref linkend="sect_CID_cp1407_003" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis>
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="5" rowspan="1">
              <para>
                <emphasis role="italic">Include <xref linkend="sect_CID_cp1407_004" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis>
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="5" rowspan="1">
              <para>
                <emphasis role="italic">Include <xref linkend="sect_CID_cp1407_005" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis>
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="5" rowspan="1">
              <para>
                <emphasis role="italic">Include <xref linkend="sect_CID_cp1407_006" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis>
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="5" rowspan="1">
              <para>
                <emphasis role="italic">Include <xref linkend="sect_CID_cp1407_007" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis>
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A6080</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Cerebellar white matter</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>33060004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152381</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2030</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Cerebral white matter</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>68523003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152295</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A7070</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Spinal cord white matter</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>27088001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0458457</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A0095</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>White matter of brain and spinal cord</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>389080008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1300311</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A0500</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Peripheral nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>84782009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0031119</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-D0684</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Skeletal muscle</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127954009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0242692</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-1300D</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Cardiac muscle</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>122448007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0027061</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113681" xrefstyle="select: nopage">113681</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Phantom</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para/>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0282611</para>
            </td>
          </tr>
          
          
        </tbody>
      </table>
          
    </section>
    
    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 - Content Mapping Resource - Controlled
              Terminology Definitions to add the following new concepts:</emphasis></para>
          </td>
        </tr>
      </informaltable>
      
      <table rules="all" frame="box" label="D-1">
        <caption>DICOM Controlled Terminology Definitions</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Definition</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Notes</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="DCM_d14070">d14070</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior optic radiation (Baum's loop)</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>That part of the optic radiation (geniculo-calcarine tract) carrying information
                from the inferior part of the visual field, and coursing superiorly, through the
                parietal lobe.</para>
              <para>As distinct from the inferior optic radiation (Meyer's Loop).</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="DCM_d14071">d14071</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior longitudinal fasciculus I</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>The dorsal component of the SLF originating from the medial and dorsal parietal
                cortex and ending in the dorsal and medial part of the frontal lobe.</para>
              <para>See Makris N, et al. "Segmentation of Subcomponents within the Superior
                Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study." Cerebral
                Cortex 15, no. 6 (June 1, 2005): 854–69. doi:10.1093/cercor/bhh186.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="DCM_d14072">d14072</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior longitudinal fasciculus II</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>The major component of the SLF, derived from the caudal–inferior parietal region
                corresponding to the angular gyrus in the human and terminating within the
                dorsolateral frontal region.</para>
              <para>See Makris N, et al. "Segmentation of Subcomponents within the Superior
                Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study." Cerebral
                Cortex 15, no. 6 (June 1, 2005): 854–69. doi:10.1093/cercor/bhh186.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="DCM_d14073">d14073</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior longitudinal fasciculus III</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>The ventral component of the SLF, originating from the supramarginal gyrus and
                terminating predominantly in the ventral premotor and prefrontal areas.</para>
              <para>See Makris N, et al. "Segmentation of Subcomponents within the Superior
                Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study." Cerebral
                Cortex 15, no. 6 (June 1, 2005): 854–69. doi:10.1093/cercor/bhh186.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para></para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
  </chapter>