  <title>CP-1407</title>
  <subtitle>Add diffusion tractography related sites</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>STATUS</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/08/12</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>James Reuss</para>
        <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
          xlink:href="mailto:jreuss@prismclinical.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/05/06</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1407</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add diffusion tractography related sites</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
        <para>PS 3.16 2014a</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
          <para>Rationale for Correction:</para>
          <para>White matter tracts and related structures (as represented with MR diffusion tensor
            tractography) need to be described with a higher degree of anatomical precision as well
            as a different concepts (tracts that span regions) than is currently defined for other
            applications such as segmentation.</para>
        </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>

    
    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Add new Context Groups to DICOM PS 3.16 Annex B Context Groups as
                follows:</emphasis></para></td></tr>
      </informaltable>
    </section>
    
    <section label="CID dac257_001" status="3" xml:id="sect_CID_dac257_001">
      <title>Fiber Tracts In Brainstem</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID dac257_001" xml:id="table_dac257_001">
        <caption>Fiber Tracts In Brainstem</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A6620</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior cerebellar peduncle</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>11089000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152391</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A6630</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>middle cerebellar peduncle</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>33723005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152392</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A6640</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior cerebellar peduncle</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>67701001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152393</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-D07EA</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>corticospinal tract in brainstem</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>360568007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1283381</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A5271</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>medial lemniscus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>30114003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228420</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A5272</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral lemniscus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>86136007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152375</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A5250</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>medial longitudinal fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>28390009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152373</para>
            </td>
          </tr>
        </tbody>
      </table>
      <note><para>Organized as described in Wakana, Setsu, Hangyi Jiang, Lidia M. Nagae-Poetscher, Peter C. M. van Zijl, and Susumu Mori. “Fiber Tract–based Atlas of Human White Matter Anatomy.” Radiology 230, no. 1 (January 1, 2004): 77–87. doi:10.1148/radiol.2301021640.</para></note>
    </section>
    
    <section label="CID dac257_002" status="3" xml:id="sect_CID_dac257_002">
      <title>Projection and Thalamic Fibers</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID dac257_002" xml:id="table_dac257_002">
        <caption>Projection and Thalamic Fibers</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>1319</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>corticobulbar tract</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1184617</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>1320</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>corticospinal tract</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0936236</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A3700</para>
            </td>
            <td align="left" colspan="1">
              <para>internal capsule</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>85637007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152341</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-D0829</para>
            </td>
            <td align="left" colspan="1">
              <para>auditory (acoustic) radiation (geniculotemporal tract)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>410726006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1455736</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2880</para>
            </td>
            <td align="left" colspan="1">
              <para>optic radiation (geniculo-calcarine tract, geniculostriate pathway)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>70105001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228277</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>1466</para>
            </td>
            <td align="left" colspan="1">
              <para>inferior optic radiation (Meyer's loop)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C3498430</para>
            </td>
          </tr>
          <tr>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="left" colspan="1">
              <para>superior optic radiation (Baum's loop)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>1726</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>anterior thalamic radiation</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C2338170</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>2081</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior thalamic radiation</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C3498751</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>2082</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior thalamic radiation</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C2332665</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>2083</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>posterior thalamic radiation</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C2336194</para>
            </td>
          </tr>
        </tbody>
      </table>
      <note>
        <orderedlist>
          <listitem>
            <para>SNOMED has codes for the corticobulbar and corticospinal tracts and thalamic
              radiations in specific regions (e.g., internal capsule), but not generic codes
              independent of their regional location, so they are not used.</para>
          </listitem>
        </orderedlist>
      </note>
    </section>
    
    <section label="CID dac257_003" status="3" xml:id="sect_CID_dac257_003">
      <title>Association Fibers</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID dac257_003" xml:id="table_dac257_003">
        <caption>Association Fibers</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2820</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior longitudinal fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>89202009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228270</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2850</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior longitudinal fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>55233005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228273</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2860</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior fronto-occipital fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>13958008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228274</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2861</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior fronto-occipital fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>35664009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228275</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2830</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>uncinate fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>26230003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228271</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2870</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>vertical occipital fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>80434005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228276</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2861</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior fronto-occipital fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>35664009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228275</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2860</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior fronto-occipital fasciculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>13958008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228274</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
    <section label="CID dac257_004" status="3" xml:id="sect_CID_dac257_004">
      <title>Limbic System Tracts</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID dac257_004" xml:id="table_dac257_004">
        <caption>Limbic System Tracts</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2840</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>cingulum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>37035000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228272</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2970</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>fornix</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>87463005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152334</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>NEU</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>286</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>stria terminalis</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0175243</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
    <section label="CID dac257_005" status="3" xml:id="sect_CID_dac257_005">
      <title>Commissural Fibers</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID dac257_005" xml:id="table_dac257_005">
        <caption>Commissural Fibers</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2980</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>anterior commissure</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>62872008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152335</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2700</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>corpus callosum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>88442005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0010090</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2730</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>genu of corpus callosum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>70215001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152321</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2710</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>splenium of corpus callosum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>23347006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152319</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2781</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>tapetum of corpus callosum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>60105000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1744614</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2760</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>forceps minor</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>42932006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152325</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2750</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>forceps major</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>80049006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0809941</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2790</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>posterior commissure</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>28997003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152327</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A4950</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>habenular commissure</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>6866008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0152363</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
    <section label="CID dac257_006" status="3" xml:id="sect_CID_dac257_006">
      <title>Cranial Nerves</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID dac257_006" xml:id="table_dac257_006">
        <caption>Cranial Nerves</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A2920</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>olfactory tract</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>3960005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0162435</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8040</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>optic nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>18234004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0029130</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8070</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>oculomotor nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>56193007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0028864</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8110</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>trochlear nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>39322007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0041159</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8150</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>trigeminal nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>27612005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0040996</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8130</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>abducens nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>80622005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0000741</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8410</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>facial nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>56052001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0015462</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8500</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>vestibulocochlear nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>8598002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0001162</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8570</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>glossopharyngeal nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>21161002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0017679</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8640</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>vagus nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>88882009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0042276</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8780</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>accessory nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>15119000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0000905</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A8820</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>hypoglossal nerve</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>37899009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0020614</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
    <section label="CID dac257_007" status="3" xml:id="sect_CID_dac257_007">
      <title>Spinal Cord Fibers</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID dac257_007" xml:id="table_dac257_007">
        <caption>Spinal Cord Fibers</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A7081</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>dorsal funiculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>59752008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228576</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A7061</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>ventral funiculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>31701002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228570</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-A7091</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral funiculus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>14892003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0228583</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
  </chapter>