<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-1406</title>
  <subtitle>Add codes for tumor sites</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>STATUS</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/11/11</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Andriy Fedorov</para>
        <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
          xlink:href="mailto:fedorov@bwh.harvard.edu"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/05/28</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1406</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add codes for tumor sites</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
        <para>PS 3.16 2014b</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
          <para>Rationale for Correction:</para>
          <para>In segmenting tumors, it is useful to be able to distinguish between primary and
            secondary tumor sites.</para>
          <para>It is also necessary to specify the finding site of primary tumors, and the
            involvement of specific lymph node groups.</para>
        </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>


    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Amend DICOM PS 3.16 Annex B Context Groups as follows:</emphasis></para></td></tr>
      </informaltable>
    </section>
    
    <section label="CID 7159" status="3" xml:id="sect_CID_7159">
      <title>Lesion Segmentation Types</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold"><emphasis role="strikethrough">20130617</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID 7159" xml:id="table_CID_7159">
        <caption>Lesion Segmentation Types</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-41610</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Abscess</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>44132006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0000833</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-35000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Blood clot</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>75753009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0302148</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-3340A</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Cyst</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>367643001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0010709</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-36300</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Edema</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>79654002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0013604</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-35300</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Embolus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>55584005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1704212</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-37000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Hemorrhage</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>50960005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0019080</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-40000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Inflammation</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>23583003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0021368</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-03000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Mass</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>4147007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0577559</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-54000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Necrosis</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>6574001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0027540</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-8FFFF</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Neoplasm</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>108369006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0027651</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">SRT</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline"
                >M-80003</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Neoplasm,
                Primary</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline"
                >86049000</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline"
                >C1306459</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">SRT</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline"
                >M-80006</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Neoplasm,
                Secondary</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline"
                >14799000</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline"
                >C2939419</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>M-03010</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Nodule</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>27925004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0028259</para>
            </td>
          </tr>
        </tbody>
      </table>

    </section>
    
    
    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Add new Context Groups to DICOM PS 3.16 Annex B Context Groups as
                follows:</emphasis></para></td></tr>
      </informaltable>
    </section>
    
    <section label="CID dac256_001" status="3" xml:id="sect_CID_dac256_001">
      <title>Lymph Node Anatomic Sites</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID dac256_001" xml:id="table_dac256_001">
        <caption>Lymph Node Anatomic Sites</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4400</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>abdominal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>8568009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0588058</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4130</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>anterior auricular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>25247006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229713</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4240</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>anterior cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>5727003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229734</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4239</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>anterior jugular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>168063007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229736</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4361</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>anterior mediastinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>5296000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229758</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4866</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>anterior tibial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>303713004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229861</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4480</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>aortic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>35783009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229789</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4740</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>apical axillary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>16051009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229842</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4592</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>appendicular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>46157003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229805</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4710</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>axillary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>68171009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0729594</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C471E</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>axillary vein lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>421624008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0447170</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4155</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>buccinator lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>143925009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229720</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C430A</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>cardiophrenic angle lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>371013005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1299596</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4410</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>celiac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>47985009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229766</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4730</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>central axillary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>283001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229841</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4200</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>81105003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0588054</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4560</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>colic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>8356004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229800</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4446</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>common duct lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>280639005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229801</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4770</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>cubital lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>34775006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229846</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4445</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>cystic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>280556009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229770</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4019</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>deep anterior cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>168360002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229735</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4202</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>deep cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279145002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0458298</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4820</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>deep inguinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>65266007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229850</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4143</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>deep intraparotid lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>75040000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229717</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4018</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>deep lateral cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>167864002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229728</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4002</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>deep lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>60996007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229698</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4146</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>deep parotid lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279142004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0458295</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4851</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>deep popliteal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>35721009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229857</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4263</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>delphian lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>167664004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229741</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4309</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>diaphragmatic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>196751009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229762</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4670</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>epigastric lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>60965003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229829</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4780</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>epitrochlear lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>28870006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229847</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4365</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>esophageal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>11899006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229760</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4620</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>external iliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>65349008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229815</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C471F</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>external mammary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>421988007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0447171</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-28812</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>extrapulmonary lymph node of lung</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>363537007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1285483</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4150</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>facial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>48918001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229719</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C463E</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>female genital lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>314736006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1282339</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4801</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>femoral lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>310545001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0588056</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4863</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>fibular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>31171007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229862</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4458</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>gastro-omental lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>83380007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229776</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4631</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>gluteal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>80867000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229824</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4404</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>gut-associated lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>72381005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229765</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C3070</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>hemolymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>18457007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229690</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4440</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>hepatic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>61492009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229769</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43A1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>highest mediastinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127926002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268042</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4320</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>hilar lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>53074004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1305372</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4630</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>hypogastric lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>69255009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229823</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4563</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>ileocolic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>281676003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229796</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4610</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>iliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>84219008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229807</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C421D</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior auricular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>155237005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229714</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4632</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior gluteal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>40684008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229825</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4843</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior inguinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>85380009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229855</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4511</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior mesenteric lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>113336002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229793</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C447D</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior pancreatic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>280915003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229787</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C447F</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inferior pancreaticoduodenal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>281227003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229785</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4280</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>infraclavicular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>9659009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229743</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4810</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>inguinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>8928004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0729596</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4305</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>innominate lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>196821008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229763</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4370</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>intercostal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>64038003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229761</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4642</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>interiliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279271008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229821</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4311</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>interlobar lymph node of the lung</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127919002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268034</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4612</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>intermediate common iliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>64556009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229809</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4622</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>intermediate external iliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>50193000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229817</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4753</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>interpectoral lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>420800007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0447172</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4500</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>intestinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>36251007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229791</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4147</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>intraglandular parotid lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>143824007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229716</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C430B</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>intramammary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>443808008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C2733350</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4308</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>intrapulmonary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>196662004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229749</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4230</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>jugular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>58130000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229731</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4423</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>juxtaintestinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279609001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229768</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4602</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lacunar lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>360993001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1283709</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4720</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral axillary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>33770006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229840</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4210</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>68915008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229727</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4613</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral common iliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>41145006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229810</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4623</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral external iliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>40242007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229818</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4238</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral jugular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>168159002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229733</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4306</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral pericardial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>196587000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229748</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4255</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral retropharyngeal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>167464007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229739</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C46AB</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lateral vesicular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>278672000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229835</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4312</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lobar lymph node of the lung</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127920008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268035</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C421A</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lower deep cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>285429007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0563315</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4237</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lower jugular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>245323006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0447166</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4800</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lower limb lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>4942000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0729767</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43A7</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lower paratracheal (including azygous) lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127932007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268048</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4490</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lumbar lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>8334002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229790</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-28910</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lung and tracheobronchial lymph nodes</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>110550009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1267244</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>59441001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0024204</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43AC</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of aortic arch</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127937001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268053</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43AD</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of aortopulmonary window</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127938006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268054</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4442</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of epiploic foramen</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>68878000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229771</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4456</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of greater curvature of stomach</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>76878005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229774</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4100</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of head</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>13482005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229710</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4004</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of head and neck</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>312501005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0729853</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4452</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of lesser curvature of stomach</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279784003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229773</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4005</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of limb</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>312503008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0729855</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4401</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of mesentery</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279795009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229792</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4414</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of stomach</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>314730000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1282334</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43B3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of the pulmonary ligament</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127941002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268057</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4300</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of thorax</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>47109002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229745</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-D200A</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node of trunk</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>312502003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0729854</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4453</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lymph node ring of cardia of stomach</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279866008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229775</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4102</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>mandibular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>155338003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229724</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4154</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>mastoid lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279143009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0458296</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4611</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>medial common iliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>34625003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229808</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4621</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>medial external iliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>42472007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229816</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4624</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>medial lacunar lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>23198005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229819</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4254</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>median retropharyngeal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>167364008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229738</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4360</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>mediastinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>62683002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0588055</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4417</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>mesenteric artery lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>299993000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0576734</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4510</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>mesenteric lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>84749006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229792</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4565</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>midcolic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>282031000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229798</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4219</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>middle deep cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>285427009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0563313</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4236</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>middle jugular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>245322001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0447167</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4156</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>nasolabial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>144026003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229721</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4626</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>obturator lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>36086000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229822</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4110</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>occipital lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>3916005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229711</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4474</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>pancreatic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>77778009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229783</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4475</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>pancreaticoduodenal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>76659008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229784</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4470</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>pancreaticosplenic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>16050005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229781</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43AE</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>para-aortic lymph node of the anterior mediastinum</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127939003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268055</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43B2</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>paraesophageal lymph node below carina</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127940001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268056</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4752</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>paramammary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>368550005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229845</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4660</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>parametrial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>3243006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229828</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C46A5</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>pararectal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>21875007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229837</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4350</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>parasternal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>82365008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229755</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4340</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>paratracheal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>65690001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229754</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C46A4</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>paravaginal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>16228004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229836</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C46A0</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>paravesicular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>1439000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229832</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4140</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>parotid lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>10209003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229715</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4750</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>pectoral axillary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>69691007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229843</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4600</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>pelvic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>54268001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0729595</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4411</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>perigastric lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>245344006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0733937</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C447A</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>peripancreatic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>245346008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0733938</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4850</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>popliteal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>47471008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0588057</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4217</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>postauricular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>245328002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229712</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4120</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>posterior auricular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>30793004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229712</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4362</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>posterior mediastinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>25447008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229759</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4867</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>posterior tibial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>303623000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229860</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4216</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>posterior triangle cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>245324000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0447168</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C46AA</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>postvesicular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>278571002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229834</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4522</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>prececal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>281765006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229803</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4822</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>prefemoral lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>48193007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229851</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4260</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>prelaryngeal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>74203007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229740</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C437C</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>prepericardial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>196516004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229747</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4680</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>presymphysial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>6413002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229830</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4244</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>pretracheal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>168460001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229742</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43A5</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>prevascular/retrotracheal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127930004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268046</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4307</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>prevertebral lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>196446004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229746</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C46A1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>prevesicular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>11740004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229833</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4641</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>promontory common iliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279189002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229813</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4460</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>pyloric lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>24889003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229777</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4003</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>regional lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>312500006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0729852</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4582</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>renal hilar lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>249708006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0278453</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4523</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>retrocecal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>281847004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229804</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4580</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>retroperitoneal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>91394001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229802</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4250</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>retropharyngeal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>25683005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229737</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4467</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>retropyloric lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>280402004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229780</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43A6</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>retrotracheal lymph node (mediastinal)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127931000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268047</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4650</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>sacral lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>79926007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229827</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4290</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>scalene lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>81132008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229744</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4313</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>segmental lymph node of the lung</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127921007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268036</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4512</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>sigmoid lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>30024008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229794</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4473</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>splenic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>280824006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229782</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4614</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>subaortic common iliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>60227002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1305374</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4332</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>subcarinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>28330007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229753</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4722</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>subclavian lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>421861001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0447173</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4616</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>subiliac lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>113338001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229814</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4160</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>submandibular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>59503006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229722</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4157</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>submaxillary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>144127009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229725</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4170</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>submental lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>46055009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229723</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4466</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>subpyloric lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>280314006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229779</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4760</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>subscapular axillary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>12196003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1735587</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4314</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>subsegmental lymph node of the lung</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127922000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268037</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C401A</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superficial anterior cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>168557005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229736</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4201</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superficial cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279144003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0458297</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4840</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superficial inguinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>113340006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229852</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4144</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superficial intraparotid lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>68339009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229718</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C421E</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superficial lateral cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>167965000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229729</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4001</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superficial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>90606007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229697</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4145</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superficial parotid lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279141006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0458294</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4852</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superficial popliteal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>12728001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229858</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4633</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior gluteal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>76290003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229826</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4842</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior lateral inguinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>76704003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229854</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4841</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior medial inguinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>52554005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229853</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43A0</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior mediastinal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127925003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268041</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4420</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior mesenteric lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>49394004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229767</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C447E</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior pancreatic lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>280999005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229788</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4481</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior pancreaticoduodenal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>281320004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229786</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4513</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior rectal lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>68881005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229795</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4331</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>superior tracheobronchial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>67941004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229752</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4220</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>supraclavicular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>76838003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229730</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4352</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>supramammary lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>62630005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229756</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4465</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>suprapyloric lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>280216006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229778</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4860</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>tibial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>80769008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229859</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4379</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>tracheobronchial lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>245341003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229751</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4330</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>tracheobronchial lymph node, located near carina</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>89858007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229751</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4218</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>upper deep cervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>285425001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0545582</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4235</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>upper jugular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>245321008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0447165</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4700</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>upper limb lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>44914007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0729769</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C43A2</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>upper paratracheal lymph node (mediastinal)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>127927006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1268043</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4690</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>uterine paracervical lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>5394000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229831</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C4601</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>vesicular lymph node</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>360992006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1283708</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
    <section label="CID dac256_002" status="3" xml:id="sect_CID_dac256_002">
      <title>Head and Neck Cancer Anatomic Sites</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">yyyymmdd</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID dac256_002" xml:id="table_dac256_002">
      <caption>Head and Neck Cancer Anatomic Sites</caption>
      <thead>
        <tr valign="top">
          <th align="center" colspan="1" rowspan="1">
            <para>
              <emphasis role="bold">Coding Scheme Designator</emphasis>
            </para>
          </th>
          <th align="center" colspan="1" rowspan="1">
            <para>
              <emphasis role="bold">Code Value</emphasis>
            </para>
          </th>
          <th align="center" colspan="1" rowspan="1">
            <para>
              <emphasis role="bold">Code Meaning</emphasis>
            </para>
          </th>
          <th align="center" colspan="1" rowspan="1">
            <para>
              <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
            </para>
          </th>
          <th align="center" colspan="1" rowspan="1">
            <para>
              <emphasis role="bold">UMLS Concept Unique ID</emphasis>
            </para>
          </th>
        </tr>
      </thead>
      <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-53131</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>base of tongue</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>7283002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0226958</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-51305</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>buccal mucosa</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>16811007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C1578559</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-51200</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>floor of mouth</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>36360002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0026638</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-24440</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>glottis</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>1307006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0017681</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-55300</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>hypopharynx</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>81502006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0020629</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-24100</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>larynx</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>4596009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0023078</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C5140</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lingual tonsil</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>2048000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229871</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-52000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lip</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>48477009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0023759</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-D07CB</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>lower alveolar ridge</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>288546009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0222755</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-22100</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>maxillary sinus </para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>15924003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0024957</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-21301</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>nasal cavity</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>279549004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0027423</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-23000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>nasopharyngeal</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>71836000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0027442</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-51004</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>oral cavity</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>74262004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0226896</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C5000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>oropharyngeal tonsil (waldeyer's ring)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>17861009</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0459892</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-55200</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>oropharynx</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>31389004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0521367</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C5100</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>palatine tonsil</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>75573002</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0040421</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-51130</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>palatine uvula</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>26140008</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0042173</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-22000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>paranasal sinus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>2095001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0030471</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C5300</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>pharyngeal tonsil (adenoid)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>55940004</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0001428</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-55320</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>pyriform sinus</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>6217003</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0227170</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-51600</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>retromolar trigone</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>85816001</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0226920</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-61007</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>salivary gland</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>385294005</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0036098</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-24454</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>supraglottis</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>119255006</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0225574</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-53000</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>tongue</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>21974007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0040408</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-C5330</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>tubal tonsil</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>21058000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0229883</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
  </chapter>
</book>