  <title>CP-1404</title>
  <subtitle>Correct Condition on Exposure in Projection X-Ray RDSR</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>STATUS</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/11/11</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/04/29</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1404</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Correct Condition on Exposure in Projection X-Ray RDSR</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
        <para>PS 3.16 2014b</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
          <para>Rationale for Correction:</para>
          <para>Exposure should be present to provide missing information when either exposure time
            or tube current are absent, not both.</para>
        </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>
    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Amend DICOM PS 3.16 Annex A Structured Reporting Templates as
                follows:</emphasis></para></td></tr>
      </informaltable>
    </section>
    
      <section label="TID 10003B" status="3" xml:id="sect_TID_10003B">
        <title>Irradiation Event X-Ray Source Data</title>
        <para>This template contains data that is expected to be available to the X-Ray source component of the equipment.</para>
        <variablelist spacing="compact">
          <varlistentry>
            <term>
              <emphasis role="bold">Type:</emphasis>
            </term>
            <listitem>
              <para>
                <emphasis role="bold">Extensible</emphasis>
              </para>
            </listitem>
          </varlistentry>
          <varlistentry>
            <term>
              <emphasis role="bold">Order:</emphasis>
            </term>
            <listitem>
              <para>
                <emphasis role="bold">Non-Significant</emphasis>
              </para>
            </listitem>
          </varlistentry>
        </variablelist>
        <table rules="all" frame="box" label="TID 10003B" xml:id="table_TID_10003B">
          <caption>Irradiation Event X-Ray Source Data</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para/>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">NL</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">Rel with Parent</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">VT</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">Concept Name</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">VM</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">Req Type</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">Condition</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">Value Set Constraint</emphasis>
                </para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>12</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>NUM</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV <link linkend="DCM_113734" xrefstyle="select: nopage">(113734, DCM, "X-Ray Tube Current")</link></para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1-n</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IF Row 15 is not present</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>UNITS = EV (mA, UCUM, "mA")</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>13</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>NUM</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV <link linkend="DCM_113767" xrefstyle="select: nopage">(113767, DCM, "Average X-Ray Tube Current")</link></para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>U</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>UNITS = EV (mA, UCUM, "mA")</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>14</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>NUM</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV <link linkend="DCM_113824" xrefstyle="select: nopage">(113824, DCM, "Exposure Time")</link></para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IF Row 15 is not present</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>UNITS = EV (ms, UCUM, "ms")</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>15</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>NUM</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV <link linkend="DCM_113736" xrefstyle="select: nopage">(113736, DCM, "Exposure")</link></para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1-n</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IF Row 12 <emphasis role="bold"><emphasis role="strikethrough">and</emphasis><emphasis role="underline">or</emphasis></emphasis> 14 are not present</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>UNITS = EV (uA.s, UCUM, "uA.s")</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para/>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
            </tr>
          </tbody>
        </table>
        <para>...</para>
      </section>
    
    
  </chapter>
</book>