<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-1390</title>
  <subtitle>Generalize Concepts in Abstract Multi-dimensional Image Model Component
    Semantics</subtitle>
  <chapter>
    <title/>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>STATUS</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>Assigned</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Date of Last Update</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>2014/06/09</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Person Assigned</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>David Clunie</para>
          <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
              xlink:href="mailto:dclunie@dclunie.com"/></para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Submitter Name</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>Andriy Fedorov</para>
          <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
              xlink:href="mailto:fedorov@bwh.harvard.edu"/></para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Submission Date</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>2014/03/03</para>
        </td>
      </tr>
    </informaltable>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Correction Number CP-1390</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Log Summary: Generalize Concepts in Abstract Multi-dimensional Image Model Component
            Semantics</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Name of Standard</para>
          <para>PS3.16 2013</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
          <para>Many of the concepts for quantities that are present in PS3.16 "Abstract Multi-dimensional Image Model Component Semantics", which are used in
            PS3.19 Application Hosting for the Abstract Model, are potentially reusable as quantities and dimensions in other use cases.</para>
          <para>The concepts listed are inconsistent with respect to whether or not they define the semantics specific to an
            image or "map" or are entirely general.</para>
          <para>Amend their definitions to replace "the image is" with "the values are". 
            Also, where there is the occasional inconsistent use of the word "map" in the name
            and defintions of these concepts it is removed, since conceptually the values
            represented when in an imahe matrix are "maps" yet this limits the reuse of the same
            concept for a single value extracted from an image (such as in a measurement in an
            ROI).</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Editor's Notes:</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
      </tr>
    </informaltable>
  </chapter>
  <chapter>
    <title/>

    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 - Content Mapping Resource -
              Context Groups to amend the following context groups:</emphasis></para>
          </td>
        </tr>
      </informaltable>

      <section label="CID 4033" status="3" xml:id="sect_CID_4033">
        <title>MR Proton Spectroscopy Metabolites</title>
        <variablelist spacing="compact">
          <varlistentry>
            <term>
              <emphasis role="bold">Type:</emphasis>
            </term>
            <listitem>
              <para>
                <emphasis role="bold">Extensible</emphasis>
              </para>
            </listitem>
          </varlistentry>
          <varlistentry>
            <term>
              <emphasis role="bold">Version:</emphasis>
            </term>
            <listitem>
              <para>
                <emphasis role="bold">20070122</emphasis>
              </para>
            </listitem>
          </varlistentry>
        </variablelist>
        <table rules="all" frame="box" label="CID 4033" xml:id="table_CID_4033">
          <caption>MR Proton Spectroscopy Metabolites</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">Coding Scheme Designator</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">Code Value</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>
                  <emphasis role="bold">Code Meaning</emphasis>
                </para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>SRT</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>F-6175A</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>N-acetylaspartate</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>SRT</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>F-61080</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Citrate</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>SRT</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>F-61620</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Choline</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>SRT</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>F-61380</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Creatine</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>DCM</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>
                  <link linkend="DCM_113094" xrefstyle="select: nopage">113094</link>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Creatine and Choline</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>SRT</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>F-61760</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Lactate</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>SRT</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>F-63600</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Lipid</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>DCM</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>
                  <link linkend="DCM_113095" xrefstyle="select: nopage">113095</link>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Lipid and Lactate</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>DCM</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>
                  <link linkend="DCM_113080" xrefstyle="select: nopage">113080</link>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Glutamate and glutamine</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>SRT</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>F-64210</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Glutamine</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>SRT</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>F-64460</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Tuarine</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>SRT</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>F-61A90</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Inositol</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>DCM</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>
                  <link linkend="DCM_113081" xrefstyle="select: nopage">113081</link>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Choline/Creatine Ratio</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>DCM</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>
                  <link linkend="DCM_113082" xrefstyle="select: nopage">113082</link>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>N-acetylaspartate/Creatine Ratio</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>DCM</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>
                  <link linkend="DCM_113083" xrefstyle="select: nopage">113083</link>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>N-acetylaspartate/Choline Ratio</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>DCM</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>
                  <link linkend="DCM_113096" xrefstyle="select: nopage">113096</link>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Creatine+Choline/Citrate Ratio</para>
              </td>
            </tr>
          </tbody>
        </table>
        <note>
          <para>For the purpose of this context group, where possible, the resonance peak in the spectrum corresponding to a particular metabolite is described using the concept from SNOMED for the substance corresponding to the metabolite. E.g., the code used for "lipid" is the code for "lipid (substance) ", as this concept is effectively post-coordinated by its use in the Metabolite Map Code Sequence (0018,9083) to mean "lipid resonance peaks in MR spectroscopy".</para>
        </note>
      </section>
      
      
    <section label="CID 7180" status="3" xml:id="sect_CID_7180">
      <title>Abstract Multi-dimensional Image Model Component Semantics</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold"><emphasis role="strikethrough">20100825</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID 7180" xml:id="table_CID_7180">
        <caption>Abstract Multi-Dimensional Image Model Component Semantics</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="3" rowspan="1">
              <para>
                <emphasis role="italic">Include <xref linkend="sect_CID_4033" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis>
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113063" xrefstyle="select: nopage">113063</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>T1<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113065" xrefstyle="select: nopage">113065</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>T2<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113064" xrefstyle="select: nopage">113064</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>T2*<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113058" xrefstyle="select: nopage">113058</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Proton Density<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110800" xrefstyle="select: nopage">110800</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Spin Tagging Perfusion MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113070" xrefstyle="select: nopage">113070</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Velocity encoded</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113067" xrefstyle="select: nopage">113067</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Temperature encoded</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110801" xrefstyle="select: nopage">110801</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Contrast Agent Angio MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110802" xrefstyle="select: nopage">110802</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Time Of Flight Angio MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110803" xrefstyle="select: nopage">110803</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Proton Density Weighted MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110804" xrefstyle="select: nopage">110804</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>T1 Weighted MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110805" xrefstyle="select: nopage">110805</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>T2 Weighted MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110806" xrefstyle="select: nopage">110806</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>T2* Weighted MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113043" xrefstyle="select: nopage">113043</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Diffusion weighted</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110807" xrefstyle="select: nopage">110807</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Field Map MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110808" xrefstyle="select: nopage">110808</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Fractional Anisotropy</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110809" xrefstyle="select: nopage">110809</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Relative Anisotropy</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113041" xrefstyle="select: nopage">113041</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Apparent Diffusion Coefficient</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110810" xrefstyle="select: nopage">110810</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Volumetric Diffusion Dxx Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110811" xrefstyle="select: nopage">110811</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Volumetric Diffusion Dxy Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110812" xrefstyle="select: nopage">110812</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Volumetric Diffusion Dxz Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110813" xrefstyle="select: nopage">110813</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Volumetric Diffusion Dyy Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110814" xrefstyle="select: nopage">110814</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Volumetric Diffusion Dyz Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110815" xrefstyle="select: nopage">110815</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Volumetric Diffusion Dzz Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110816" xrefstyle="select: nopage">110816</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>T1 Weighted Dynamic Contrast Enhanced MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110817" xrefstyle="select: nopage">110817</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>T2 Weighted Dynamic Contrast Enhanced MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110818" xrefstyle="select: nopage">110818</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>T2* Weighted Dynamic Contrast Enhanced MR Signal Intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113055" xrefstyle="select: nopage">113055</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Regional Cerebral Blood Flow</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113056" xrefstyle="select: nopage">113056</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Regional Cerebral Blood Volume</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113052" xrefstyle="select: nopage">113052</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Mean Transit Time</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113069" xrefstyle="select: nopage">113069</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Time To Peak<emphasis role="bold"><emphasis role="strikethrough"> map</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110819" xrefstyle="select: nopage">110819</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Blood Oxygenation Level</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110820" xrefstyle="select: nopage">110820</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Nuclear Medicine Projection Activity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110821" xrefstyle="select: nopage">110821</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Nuclear Medicine Tomographic Activity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110822" xrefstyle="select: nopage">110822</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Spatial Displacement X Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110823" xrefstyle="select: nopage">110823</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Spatial Displacement Y Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110824" xrefstyle="select: nopage">110824</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Spatial Displacement Z Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110825" xrefstyle="select: nopage">110825</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Hemodynamic Resistance</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110826" xrefstyle="select: nopage">110826</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Indexed Hemodynamic Resistance</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_112031" xrefstyle="select: nopage">112031</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Attenuation Coefficient</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110827" xrefstyle="select: nopage">110827</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Tissue Velocity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110828" xrefstyle="select: nopage">110828</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Flow Velocity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>P0-02241</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Power Doppler</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110829" xrefstyle="select: nopage">110829</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Flow Variance</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110830" xrefstyle="select: nopage">110830</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Elasticity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110831" xrefstyle="select: nopage">110831</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Perfusion</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110832" xrefstyle="select: nopage">110832</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Speed of sound</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110833" xrefstyle="select: nopage">110833</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Ultrasound Attenuation</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113068" xrefstyle="select: nopage">113068</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Student's T-test</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113071" xrefstyle="select: nopage">113071</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Z-score<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_113057" xrefstyle="select: nopage">113057</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>R-Coefficient<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">DCM</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold"><emphasis role="underline"><link linkend="DCM_dd1390_01" xrefstyle="select: nopage">dd1390_01</link></emphasis></emphasis>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">R2-Coefficient</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110834" xrefstyle="select: nopage">110834</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>RGB R Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110835" xrefstyle="select: nopage">110835</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>RGB G Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110836" xrefstyle="select: nopage">110836</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>RGB B Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110837" xrefstyle="select: nopage">110837</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR FULL Y Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110838" xrefstyle="select: nopage">110838</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR FULL CB Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110839" xrefstyle="select: nopage">110839</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR FULL CR Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110840" xrefstyle="select: nopage">110840</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR PARTIAL Y Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110841" xrefstyle="select: nopage">110841</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR PARTIAL CB Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110842" xrefstyle="select: nopage">110842</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR PARTIAL CR Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110843" xrefstyle="select: nopage">110843</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR ICT Y Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110844" xrefstyle="select: nopage">110844</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR ICT CB Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110845" xrefstyle="select: nopage">110845</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR ICT CR Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110846" xrefstyle="select: nopage">110846</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR RCT Y Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110847" xrefstyle="select: nopage">110847</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR RCT CB Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110848" xrefstyle="select: nopage">110848</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>YBR RCT CR Component</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110849" xrefstyle="select: nopage">110849</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Echogenicity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110850" xrefstyle="select: nopage">110850</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>X-Ray Attenuation</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110851" xrefstyle="select: nopage">110851</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>X-Ray Attenuation Coefficient</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110852" xrefstyle="select: nopage">110852</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>MR signal intensity</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110853" xrefstyle="select: nopage">110853</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Binary Segmentation</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110854" xrefstyle="select: nopage">110854</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Fractional Probabilistic Segmentation</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_110855" xrefstyle="select: nopage">110855</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Fractional Occupancy Segmentation</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>

    </section>
    
    
    
    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 - Content Mapping Resource - Controlled
                Terminology Definitions to make suitable for use both as Abstract Multi-dimensional
                Image Model Component Semantics and Quantity Descriptor:</emphasis></para>
          </td>
        </tr>
      </informaltable>

      <table rules="all" frame="box" label="D-1">
        <caption>DICOM Controlled Terminology Definitions</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Definition</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Notes</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="DCM_112031">112031</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Attenuation Coefficient</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>A quantitative numerical statement of the relative attenuation of the X-Ray beam at a specified point. Usually expressed in Hounsfield units [referred to as CT Number in Fraser and Pare].</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para/>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
          </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113041">113041</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Apparent Diffusion Coefficient</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculation of the apparent diffusion coefficient.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113042">113042</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Pixel by pixel addition</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by the pixel by pixel addition of two images.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113043">113043</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Diffusion weighted</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculation of the diffusion weighting.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113044">113044</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Diffusion Anisotropy</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculation of the diffusion anisotropy.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113045">113045</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Diffusion Attenuated</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculation of the diffusion attenuation.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113046">113046</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Pixel by pixel division</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by the pixel by pixel division of two images.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113047">113047</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Pixel by pixel mask</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by the pixel by pixel masking of one image by another.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113048">113048</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Pixel by pixel Maximum</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating the pixel by pixel maximum of two or more images.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113049">113049</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Pixel by pixel mean</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating the pixel by pixel mean of two or more images.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113050">113050</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Metabolite Maps from spectroscopy data</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating from spectroscopy data pixel values localized in two dimensional space based on the concentration of specific metabolites (i.e, at specific frequencies).</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113051">113051</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Pixel by pixel Minimum</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating the pixel by pixel minimum of two or more images.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113052">113052</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Mean Transit Time</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating mean transit time values.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113053">113053</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Pixel by pixel multiplication</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by the pixel by pixel multiplication of two images.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113054">113054</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Negative Enhancement Integral</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating negative enhancement integral values.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113055">113055</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Regional Cerebral Blood Flow</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating regional cerebral blood flow values.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113056">113056</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Regional Cerebral Blood Volume</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating regional cerebral blood volume values.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113057">113057</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>R-Coefficient Map</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is derived by calculating R-</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Correlation </emphasis></emphasis>Coefficient<emphasis role="bold"><emphasis role="underline">, r</emphasis></emphasis><emphasis role="bold"><emphasis role="strikethrough"> map values</emphasis></emphasis>.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113058">113058</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Proton Density<emphasis role="bold"><emphasis role="strikethrough"> map</emphasis></emphasis></para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating proton density values.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113059">113059</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal Change<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating signal change values.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113060">113060</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal to Noise<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating the signal to noise ratio.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113061">113061</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Standard Deviation</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating the standard deviation of two or more images.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113062">113062</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Pixel by pixel subtraction</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by the pixel by pixel subtraction of two images.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113063">113063</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>T1<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating T1 values.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113064">113064</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>T2*<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating T2* values.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113065">113065</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>T2<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating T2 values.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113066">113066</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Time Course of Signal</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating values based on the time course of signal.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113067">113067</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Temperature encoded</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating values based on temperature encoding.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113068">113068</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Student's T-Test</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating the value of the Student's T-Test statistic from multiple image samples.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113069">113069</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Time To Peak<emphasis role="bold"><emphasis role="strikethrough"> map</emphasis></emphasis></para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating values based on the time to peak.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113070">113070</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Velocity encoded</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating values based on velocity encoded. E.g., phase contrast.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113071">113071</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Z-Score<emphasis role="bold"><emphasis role="strikethrough"> Map</emphasis></emphasis></para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by calculating the value of the Z-Score statistic from multiple image samples.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113072">113072</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Multiplanar reformatting</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by reformatting in a flat plane other than that originally acquired.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113073">113073</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Curved multiplanar reformatting</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by reformatting in a curve plane other than that originally acquired.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113074">113074</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Volume rendering</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by volume rendering of acquired data.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113075">113075</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Surface rendering</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by surface rendering of acquired data.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113076">113076</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Segmentation</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by segmentation (classification into tissue types) of acquired data.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113077">113077</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Volume editing</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by selectively editing acquired data (removing values from the volume), such as in order to remove obscuring structures or noise.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113078">113078</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Maximum intensity projection</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by maximum intensity projection of acquired data.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113079">113079</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Minimum intensity projection</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by minimum intensity projection of acquired data.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113080">113080</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Glutamate and glutamine</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>For single-proton MR spectroscopy, the resonance peak corresponding to glutamate and glutamine.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113081">113081</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Choline/Creatine Ratio</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>For single-proton MR spectroscopy, the ratio between the Choline and Creatine resonance peaks.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113082">113082</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>N-acetylaspartate /Creatine Ratio</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>For single-proton MR spectroscopy, the ratio between the N-acetylaspartate and Creatine resonance peaks.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113083">113083</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>N-acetylaspartate /Choline Ratio</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>For single-proton MR spectroscopy, the ratio between the N-acetylaspartate and Choline resonance peaks.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113085">113085</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Spatial resampling</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by spatial resampling of acquired data.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113086">113086</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Edge enhancement</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by edge enhancement.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113087">113087</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Smoothing</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by smoothing.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113088">113088</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Gaussian blur</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by Gaussian blurring.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113089">113089</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Unsharp mask</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by unsharp masking.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113090">113090</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Image stitching</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para><emphasis role="bold"><emphasis role="strikethrough">The image is</emphasis></emphasis><emphasis role="bold"><emphasis role="underline">Values are</emphasis></emphasis> derived by stitching two or more images together.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113091">113091</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Spatially-related frames extracted from the volume</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Spatially-related frames in this image are representative frames from the
              referenced 3D volume data set.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113092">113092</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Temporally-related frames extracted from the set of volumes</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Temporally-related frames in this image are representative frames from the
              referenced 3D volume data set.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113093">113093</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Polar to Rectangular Scan Conversion</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Conversion of a polar coordinate image to rectangular (Cartesian) coordinate image.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113094">113094</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Creatine and Choline</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>For single-proton MR spectroscopy, the resonance peak corresponding to creatine and choline.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113095">113095</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Lipid and Lactate</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>For single-proton MR spectroscopy, the resonance peak corresponding to lipid and lactate.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113096">113096</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Creatine+Choline/ Citrate Ratio</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>For single-proton MR spectroscopy, the ratio between the Choline and Creatine resonance peak and the Citrate resonance peak.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_113097">113097</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Multi-energy proportional weighting</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Image pixels created through proportional weighting of multiple acquisitions at distinct X-Ray energies.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>...</para>
            </td>
          </tr>
          <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110800">110800</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Spin Tagging Perfusion MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a Spin tagging Perfusion MR image. Spin tagging is a technique for the measurement of blood perfusion, based on magnetically labeled arterial blood water as an endogenous tracer.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110801">110801</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Contrast Agent Angio MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a Contrast Agent Angio MR image.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110802">110802</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Time Of Flight Angio MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a Time-of-flight (TOF) MR image. Time-of-flight (TOF) is based on the phenomenon of flow-related enhancement of spins entering into an imaging slice. As a result of being unsaturated, these spins give more signal that surrounding stationary spins.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110803">110803</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Proton Density Weighted MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a Proton Density Weighted MR image. All MR images have intensity proportional to proton density. Images with very little T1 or T2 weighting are called 'PD-weighted'.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110804">110804</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>T1 Weighted MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of T1 Weighted MR image. A T1 Weighted MR image is created typically by using short TE and TR times.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110805">110805</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>T2 Weighted MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a T2 Weighted MR image. T2 Weighted image contrast state is approached by imaging with a TR long compared to tissue T1 (to reduce T1 contribution to image contrast) and a TE between the longest and shortest tissue T2s of interest.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110806">110806</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>T2* Weighted MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a T2* Weighted MR image. The T2* phenomenon results from molecular interactions (spin spin relaxation) and local magnetic field non-uniformities, which cause the protons to precess at slightly different frequencies.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110807">110807</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Field Map MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a Field Map MR image. A Field Map MR image provides a direct measure of the 
            <emphasis role="italic">B</emphasis><subscript>0</subscript> inhomogeneity at each point in the image.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110808">110808</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Fractional Anisotropy</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Coefficient reflecting the fractional anisotropy of the tissues, derived from a diffusion weighted MR image. Fractional anisotropy is proportional to the square root of the variance of the Eigen values divided by the square root of the sum of the squares of the Eigen values.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110809">110809</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Relative Anisotropy</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Coefficient reflecting the relative anisotropy of the tissues, derived from a diffusion weighted MR image.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110810">110810</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Volumetric Diffusion Dxx Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Dxx Component of the diffusion tensor, quantifying the molecular mobility along the X axis.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110811">110811</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Volumetric Diffusion Dxy Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Dxy Component of the diffusion tensor, quantifying the correlation of molecular displacements in the X and Y directions.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110812">110812</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Volumetric Diffusion Dxz Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Dxz Component of the diffusion tensor, quantifying the correlation of molecular displacements in the X and Z directions.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110813">110813</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Volumetric Diffusion Dyy Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Dyy Component of the diffusion tensor, quantifying the molecular mobility along the Y axis.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110814">110814</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Volumetric Diffusion Dyz Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Dyz Component of the diffusion tensor, quantifying the correlation of molecular displacements in the Y and Z directions.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110815">110815</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Volumetric Diffusion Dzz Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Dzz Component of the diffusion tensor, quantifying the molecular mobility along the Z axis.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110816">110816</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>T1 Weighted Dynamic Contrast Enhanced MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a T1 Weighted Dynamic Contrast Enhanced MR image. A T1 Weighted Dynamic Contrast Enhanced MR image reflects the dynamics of diffusion of the exogenous contrast media from the blood pool into the extra vascular extracellular space (EES) of the brain at a rate determined by the blood flow to the tissue, the permeability of the Brain Blood Barrier (BBB), and the surface area of the perfusing vessels.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110817">110817</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>T2 Weighted Dynamic Contrast Enhanced MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a T2 Weighted Dynamic Contrast Enhanced MR image. A T2 Weighted Dynamic Contrast Enhanced MR image reflects the T2 of tissue decrease as the Gd contrast agent bolus passes through the brain.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110818">110818</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>T2* Weighted Dynamic Contrast Enhanced MR Signal Intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a T2* Weighted Dynamic Contrast Enhanced MR image. A T2* Weighted Dynamic Contrast Enhanced MR image reflects the T2* of tissue decrease as the Gd contrast agent bolus passes through the brain.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110819">110819</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Blood Oxygenation Level</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of a Blood Oxygenation Level image. BOLD imaging is sensitive to blood oxygenation (but also to cerebral blood flow and volume). This modality is essentially used for detecting brain activation (functional MR).</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110820">110820</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Nuclear Medicine Projection Activity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Accumulated decay event counts in a nuclear medicine projection image.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110821">110821</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Nuclear Medicine Tomographic Activity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Accumulated decay event counts in a Nuclear Medicine Tomographic image (including PET).</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110822">110822</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Spatial Displacement X Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Spatial Displacement along axis X of a non linear deformable spatial registration image. The X axis is defined in reference to the patient's orientation, and is increasing to the left hand side of the patient.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110823">110823</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Spatial Displacement Y Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Spatial Displacement along axis Y of a non linear deformable spatial registration image. The Y axis is defined in reference to the patient's orientation, and is increasing to the posterior side of the patient.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110824">110824</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Spatial Displacement Z Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Spatial Displacement along axis Z of a Non linear deformable spatial registration image. The Z axis is defined in reference to the patient's orientation, and is increasing toward the head of the patient.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110825">110825</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Hemodynamic Resistance</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Measured resistance to the flow of blood. E.g., through the vasculature or through a heart value.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110826">110826</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Indexed Hemodynamic Resistance</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Measured resistance to the flow of blood. E.g., through the vasculature or through a heart value, normalized to a particular indexed scale.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110827">110827</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Tissue Velocity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Velocity of tissue based on Doppler measurements.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110828">110828</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Flow Velocity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Velocity of blood flow based on Doppler measurements.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110829">110829</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Flow Variance</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Statistical variance of blood velocity relative to mean.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110830">110830</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Elasticity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Scalar value related to the elastic properties of the tissue.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110831">110831</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Perfusion</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Scalar value related to the volume of blood perfusing into tissue.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110832">110832</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Speed of sound</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Speed of sound in tissue.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110833">110833</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Ultrasound Attenuation</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Reduction in strength of ultrasound signal as the wave.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110834">110834</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>RGB R Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Red component of a true color image (RGB).</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110835">110835</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>RGB G Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Green component of a true color image (RGB).</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110836">110836</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>RGB B Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Blue component of a true color image (RGB).</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110837">110837</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR FULL Y Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Y (Luminance) component of a YBR FULL image, as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110838">110838</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR FULL CB Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>CB (Blue chrominance) component of a YBR FULL image, as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110839">110839</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR FULL CR Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>CR (Red chrominance) component of a YBR FULL image, as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110840">110840</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR PARTIAL Y Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Y (Luminance) component of a YBR PARTIAL image, as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110841">110841</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR PARTIAL CB Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>CB (Blue chrominance) component of a YBR PARTIAL image, as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110842">110842</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR PARTIAL CR Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>CR (Red chrominance) component of a YBR PARTIAL image, as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110843">110843</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR ICT Y Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Y (Luminance) component of a YBR ICT image (Irreversible Color Transform), as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110844">110844</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR ICT CB Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>CB (Blue chrominance) component of a YBR ICT image (Irreversible Color Transform), as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110845">110845</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR ICT CR Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>CR (Red chrominance) component of a YBR ICT image (Irreversible Color Transform), as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110846">110846</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR RCT Y Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Y (Luminance) component of a YBR RCT image (Reversible Color Transform), as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110847">110847</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR RCT CB Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>CB (Blue chrominance) component of a YBR RCT image (Reversible Color Transform), as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110848">110848</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>YBR RCT CR Component</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>CR (Red chrominance) component of a YBR RCT image (Reversible Color Transform), as defined in JPEG 2000.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110849">110849</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Echogenicity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>The ability of a material to create an ultrasound return echo.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110850">110850</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>X-Ray Attenuation</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Decrease in the number of photons in an X-Ray beam due to interactions with the atoms of a material substance. Attenuation is due primarily to two processes, absorption and scattering.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110851">110851</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>X-Ray Attenuation Coefficient</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Coefficient that describes the fraction of a beam of X-Rays or gamma rays that is absorbed or scattered per unit thickness of the absorber. This value basically accounts for the number of atoms in a cubic cm volume of material and the probability of a photon being scattered or absorbed from the nucleus or an electron of one of these atoms.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110852">110852</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>MR signal intensity</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Signal intensity of an MR image, not otherwise specified.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110853">110853</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Binary Segmentation</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Binary value denoting that the segmented property is present.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_110854">110854</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Fractional Probabilistic Segmentation</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para>Probability, defined as a percentage, that the segmented property occupies the spatial area defined by the voxel.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para/>
          </td>
        </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="DCM_110855">110855</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Fractional Occupancy Segmentation</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Percentage of the voxel area occupied by the segmented property.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para/>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="DCM_dd1390_01"><emphasis role="bold"><emphasis role="underline">dd1390_01</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">R2-Coefficient</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Coefficient of determination,
                    R<superscript>2</superscript>. An indication of goodness of fit.</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para/>
            </td>
          </tr>
        </tbody>
      </table>

    </section>
  </chapter>
</book>
