<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-1370</title>
  <subtitle>Conformance Statement Example is Missing Private Creator Value</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>STATUS</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/09/08</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/02/05</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1370</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Conformance Statement Example is Missing Private Creator Value</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
        <para>PS3.2 2014b</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction: Unlike the other examples of private attributes in PS3.2, one
            example is missing a value for the Private Creator.</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>
    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Amend DICOM PS3.2 as follows:</emphasis></para></td></tr>
      </informaltable>

      <section xml:id="sect_B.8.2" label="B.8.2">
        <title>Data Dictionary of Private Attributes</title>
        
        <para>The Private Attributes added to created SOP Instances are listed in the Table below. EXAMPLE-INTEGRATED-MODALITY reserves blocks of private attributes in groups 0009, 0019 and 0029. Further details on usage of these private attributes are contained in Section 8.1.</para>
        <table frame="box" label="B.8.2-1" rules="all" xml:id="table_B.8.2-1">
          <caption>Data Dictionary of Private Attributes</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para>Tag</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Attribute Name</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>VR</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>VM</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="underline">Value</emphasis></emphasis></para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>(0009,00xx)</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Private Creator</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>LO</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="underline">EXINTMODMAKER</emphasis></emphasis></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>(0019,00xx)</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Private Creator</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>LO</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="underline">EXINTMODMAKER</emphasis></emphasis></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>(0029,00xx)</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Private Creator</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>LO</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="underline">EXINTMODMAKER</emphasis></emphasis></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
            </tr>

          </tbody>
        </table>
      </section>
      

    </section>
  </chapter>
</book>