  <title>CP-1366</title>
  <subtitle>Correction of Relationships in Planar and Volumetric ROI Templates</subtitle>
  <chapter>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>STATUS</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Sep 2014 Voting Packet</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/06/27</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Andriy Fedorov</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:fedorov@bwh.harvard.edu"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/01/16</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1366</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Correction of Relationships in Planar and Volumetric ROI Templates</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
        <para>PS3.16 2013</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Rationale for Correction:</para>
        <para>Some of the templates added in CP 1112 define a CONTAINER content item with children that do not have valid relationships.</para>
        <para>Replace them with CONTAINS relationships.</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>
    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Amend DICOM PS3.16 - Content Mapping Resource - Structured Reporting
                Templates as follows:</emphasis></para></td></tr>
      </informaltable>
      <section label="TID 1410" status="3" xml:id="sect_TID_1410">
        <title>Planar ROI Measurements</title>
        <para>...</para>
        <table rules="all" frame="box" label="TID 1410" xml:id="table_TID_1410">
          <caption>Planar ROI Measurements</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para></para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>NL</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Rel with Parent</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>VT</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Concept Name</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>VM</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Req Type</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Condition</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Value Set Constraint</para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>CONTAINER</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (125007, DCM, "Measurement Group")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>M</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>2</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>HAS OBS CONTEXT</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>TEXT</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>DT (112039, DCM, "Tracking Identifier")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>M</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>HAS OBS CONTEXT</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>UIDREF</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (112040, DCM, "Tracking Unique Identifier")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>M</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>4</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="strikethrough">HAS OBS CONTEXT</emphasis></emphasis>
                  <emphasis role="bold"><emphasis role="underline"
                  >CONTAINS</emphasis></emphasis></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>SCOORD</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (111030, DCM, "Image Region")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>XOR Row 6</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>GRAPHIC TYPE = not {MULTIPOINT}</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>5</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>SELECTED FROM</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IMAGE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>M</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>6</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="strikethrough">HAS OBS
                      CONTEXT</emphasis></emphasis>
                  <emphasis role="bold"><emphasis role="underline"
                  >CONTAINS</emphasis></emphasis></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IMAGE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (121214, DCM, "Referenced Segmentation Frame")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>XOR Row 4</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Reference shall be to a Segmentation Image, with a single value specified in Referenced Frame Number, and with a single value specified in Referenced Segment Number</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>7</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="strikethrough">HAS
                    PROPERIES</emphasis></emphasis>
                  <emphasis role="bold"><emphasis role="underline"
                  >CONTAINS</emphasis></emphasis></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IMAGE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (121233, DCM, "Source image for segmentation")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IFF Row 6</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>8</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>CONTAINS</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IMAGE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (121200, DCM, "Illustration of ROI")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>U</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>9</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>CONTAINS</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>INCLUDE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>DTID 1419  "ROI Measurements"</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1-n</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>M</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
            </tr>
          </tbody>
        </table>
        <para>...</para>
      </section>
      <section label="TID 1411" status="3" xml:id="sect_TID_1411">
        <title>Volumetric ROI Measurements</title>
        <para>...</para>
        <table rules="all" frame="box" label="TID 1411" xml:id="table_TID_1411">
          <caption>Volumetric ROI Measurements</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para></para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>NL</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Rel with Parent</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>VT</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Concept Name</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>VM</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Req Type</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Condition</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para>Value Set Constraint</para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>CONTAINER</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (125007, DCM, "Measurement Group")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>M</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>2</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>HAS OBS CONTEXT</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>TEXT</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>DT (112039, DCM, "Tracking Identifier")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>M</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>HAS OBS CONTEXT</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>UIDREF</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (112040, DCM, "Tracking Unique Identifier")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>M</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>4</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="strikethrough">HAS OBS
                      CONTEXT</emphasis></emphasis>
                  <emphasis role="bold"><emphasis role="underline"
                  >CONTAINS</emphasis></emphasis></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>SCOORD</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (111030, DCM, "Image Region")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1-n</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>XOR Rows 6, 9</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>GRAPHIC TYPE = not {MULTIPOINT}</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>5</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>SELECTED FROM</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IMAGE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>M</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>6</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="strikethrough">HAS OBS
                      CONTEXT</emphasis></emphasis>
                  <emphasis role="bold"><emphasis role="underline"
                  >CONTAINS</emphasis></emphasis></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IMAGE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (121191, DCM, "Referenced Segment")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>XOR Rows 4, 9</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>Reference shall be to a Segmentation Image or Surface Segmentation object, with a single value specified in Referenced Segment Number</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>7</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="strikethrough">HAS PROPERTIES</emphasis></emphasis>
                  <emphasis role="bold"><emphasis role="underline"
                  >CONTAINS</emphasis></emphasis></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IMAGE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (121233, DCM, "Source image for segmentation")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1-n</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>XOR Row 8 and IFF Row 6</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>8</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="strikethrough">HAS PROPERTIES</emphasis></emphasis>
                  <emphasis role="bold"><emphasis role="underline"
                  >CONTAINS</emphasis></emphasis></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>UIDREF</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (121232, DCM, "Source series for image segmentation")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>XOR Row 7 and IFF Row 6</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>9</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="strikethrough">HAS OBS
                      CONTEXT</emphasis></emphasis>
                  <emphasis role="bold"><emphasis role="underline"
                  >CONTAINS</emphasis></emphasis></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>SCOORD3D</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (121231, DCM, "Volume Surface")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>XOR Rows 4, 6</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>GRAPHIC TYPE = {ELLIPSOID}</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>10</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="strikethrough">HAS PROPERTIES</emphasis></emphasis>
                  <emphasis role="bold"><emphasis role="underline"
                  >CONTAINS</emphasis></emphasis></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IMAGE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (121233, DCM, "Source image for segmentation")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1-n</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>XOR Row 11 and IFF Row 9</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>11</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para><emphasis role="bold"><emphasis role="strikethrough">HAS PROPERTIES</emphasis></emphasis>
                  <emphasis role="bold"><emphasis role="underline"
                  >CONTAINS</emphasis></emphasis></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>UIDREF</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (121232, DCM, "Source series for segmentation")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>MC</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>XOR Row 10 and IFF Row 9</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>12</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>CONTAINS</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>IMAGE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>EV (121200, DCM, "Illustration of ROI")</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1-n</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>U</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>13</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>&gt;</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>CONTAINS</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>INCLUDE</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>DTID 1419 "ROI Measurements"</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>1-n</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>M</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para></para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
            </tr>
          </tbody>
        </table>
      </section>
    </section>
  </chapter>
</book>