| DICOM PS3.18 2024e - Web Services |
|---|
For each matching Series, the origin server shall return all Attributes listed in Table 10.6.3-4. The "Type" column in the table below refers to the Query/Retrieve Attribute Types defined in Section C.2.2.1 “Attribute Types” in PS3.4. The unique key for a Series resource Search response is the Series Instance UID (0020,000E).
Table 10.6.3-4. Series Resources Search Response Payload
While some of the above Attributes in are optional in Table C.6-3 “Series Level Attributes for the Patient Root Query/Retrieve Information Model” in PS3.4, they are consistent with the those required in [IHE RAD TF Vol2] Table 4.14-1.
If either Prior Record Key (0008,041C) or Record Key (0008,041B) is present in the request and the origin server supports these attributes, then the responses are ordered as defined in Section C.6.4 “Repository Query SOP Class” in PS3.4.
In addition, the response shall contain:
All other Series Level Attributes passed as match Query Parameters, or Series or Study Level Attributes passed as includefield parameters in the request that are supported by the origin server.
If the "includefield" parameter has been specified in the request and its value is "all", include all Series Level Attributes specified as Optional Keys in Section C.6.1.1.4 “Series Level” in PS3.4 that are supported by the origin server.
If the Target Resource is All Series, then include all Study Level Attributes specified in Section 10.6.3.3.1.
If a Private Data Element has been specified as an include parameter and it is supported by the origin server, the Private Data Element and its corresponding Private Creator Element.
Instance Level Attributes contained in includefield parameters shall not be returned.
| DICOM PS3.18 2024e - Web Services |
|---|